HomeMy WebLinkAboutPP - 8531 EAST MARGINAL WAY SOUTH - JORGENSEN FORGE CORPORATION - PERMITS AND PLANS8531 EAST MARGINAL WAY SOUTH ASSOCIATED PERMITS 10-F-001 Ansul CO2 FLOW CALCULATION PROGRAM Version 4.2.0 Data Input File:Data file name: C:1Program FilesIHP CO2 FLOWIQ1.hp2 with unsaved revisions. Job: 0939 Customer: JORGENSEN FORGE Address: SEATTLE REMARKS: Q6 QUENCH TANK 100# MAIN & RESERVE System Conditions Number of cylinders: 1 each containing 100 lbs CO2. Total agent 100 lbs Engineering units (ft, lbs, psia) are specified Local Application system Flow rate is specified for each nozzle Calculation based on 70 degree Fahrenheit pre -discharge Pipeline Temperature Pipe Data Input Sec Sec Nominal Length Elev 90's Side Thru Union/ Qty EqI Start End Pipe Size (ft) (ft) Tee Tee Cplg CO2 (ft) 1 2 1/2 - 40T 0.10 0.00 0 0 0 0 0.00 38.0 2 3 1/2 - 80T 30.00 -8.00 9 0 0 0 0.00 13.0 3 501 1/2 - 40T 6.00 4.00 3 2* 0 0 11.00 0.0 3 502 1/2 - 40T 6.00 4.00 3 2* 0 0 11.00 0.0 * Section contains one or more side tees configured as dirt traps. 1 (End of Data Input File Printout) Ansul Incorporated HP CO2 FLOW CALCULATIONS Version 4. 2.0 Data input file name: C:\Program Files1HP CO2 FLOWIQ1.hp2 0939 SEATTLE REMARKS: Q6 QUENCH TANK 100# MAIN & RESERVE Engineering units (ft, lbs, psia) are specified Local Application system Flow rate is specified for each nozzle Agent Storage Conditions Nominal Storage Pressure is 750 psi at 70 degrees Fahrenheit 100 lbs of carbon dioxide is stored in each of 1 cylinders. Total carbon dioxide discharged is 100 lbs Pressure Drop Results Sec Sec Nominal Length Equiv Elev Tee/ Start Term Flow Start End Pipe Size (ft) Length(ft) (ft) Mfld psi psi (lbs/min) 1 2 1/2 40 T 0.1 38.1 0.0 CV -98 750 748 22.0 2 3 1/2 40 T 30.0 57.0 -8.0 748 748 22.0 3 501 1/2 40 T 6.0 16.9 4.0 BHT 748 747 11.0 3 502 1/2 40 T 6.0 16.9 4.0 BHT 748 747 11.0 Calculation based on 70 degree Fahrenheit pre -discharge Pipeline Temperature Nozzle Performance Summary Nozzle Nominal Nozzle Weight (lbs) Initial Vapor Liquid End of Discharge Number Pipe Size Code Discharged Time (sec) Time (sec) Time (sec) 501 1/2 40 T 1.80 50.0 3.6 193.0 196.6 502 1/2 40 T 1.80 50.0 3.6 193.0 196.6 Total carbon dioxide discharged is 100 lbs Messages Hydraulic calculation was successful. Shortest liquid discharge time for Local Application Nozzle is 193. sec Calculation performed on 12/10/2009 2:14:22 PM Calculation by Suppression Systems, Inc. Steven Tuck 4417 Pacific Hwy E Tacoma WA 98424-2611 US Telephone: 253-926-3300 Fax: 253-926-3306 12/10/2009 Time: 2:14:40 PM 1 End of Printout Ansul CO2 FLOW CALCULATION PROGRAM Version 4. 2. 0 Data Input File:Data file name: C:\Program Files\HP CO2 FLOW1Q6.hp2 with unsaved revisions. Job: 0939 Customer: JORGENSEN FORGE Address: SEATTLE REMARKS: Q1 QUENCH TANK 200# MAIN & RESERVE System Conditions Number of cylinders: 2 each containing 100 lbs CO2. Total agent 200 lbs Engineering units (ft, lbs, psia) are specified Local Application system Flow rate is specified for each nozzle Calculation based on 70 degree Fahrenheit pre -discharge Pipeline Temperature Pipe Data Input Sec Sec Nominal Length Elev 90's Side Thru Union/ Qty Eql Start End Pipe Size (ft) (ft) Tee Tee Cplg CO2 (ft) 1 2 1/2 - 40T 0.10 0.00 0 0 0 0 0.00 38.0 2 3 3/4 - 80T 1.00 0.00 0 0 1 0 0.00 24.0 3 4 3/4 - 80T 50.00 -8.00 6 0 0 0 0.00 17.0 4 5 3/4 - DFT 6.00 0.00 1 1 0 0 0.00 0.0 5 503 3/4 - DFT 1.00 0.00 0 1 0 0 23.00 0.0 5 6 3/4 - DFT 2.00 0.00 0 0 1 0 0.00 0.0 6 504 3/4 - DFT 1.00 0.00 0 1 0 0 23.00 0.0 6 505 3/4 - DFT 2.00 0.00 1 1* 1 0 23.00 0.0 4 7 3/4 - DFT 6.00 0.00 1 1 0 0 0.00 0.0 7 506 3/4 - DFT 1.00 0.00 0 1 0 0 23.00 0.0 7 8 3/4 - DFT 2.00 0.00 0 0 1 0 0.00 0.0 8 507 3/4 - DFT 1.00 0.00 0 1 0 0 23.00 0.0 8 508 3/4 - DFT 2.00 0.00 1 1* 1 0 23.00 0.0 * Section contains one or more side tees configured as dirt traps. 1 (End of Data Input File Printout) Ansul Incorporated HP CO2 FLOW CALCULATIONS Version 4. 2.0 Data input file name: C:IProgram Files\HP CO2 FLOWIQ6.hp2 0939 SEATTLE REMARKS: Q1 QUENCH TANK 200# MAIN & RESERVE Engineering units (ft, lbs, psia) are specified Local Application system Flow rate is specified for each nozzle Agent Storage Conditions Nominal Storage Pressure is 750 psi at 70 degrees Fahrenheit 100 lbs of carbon dioxide is stored in each of 2 cylinders. Total carbon dioxide discharged is 200 lbs Pressure Drop Results Sec Sec Nominal Length Equiv Elev Start End Pipe Size (ft) Length(ft) (ft) Tee/ Mfld 1 2 1/2 40 T 0.1 38.1 0.0 CV -98 2 3 3/4 40 T 1.0 26.4 0.0 2 cyl 3 4 3/4 40 T 50.0 79.4 -8.0 4 5 3/4 40 T 6.0 12.2 0.0 BHT 5 503 3/4 40 T 1.0 5.1 0.0 Side 5 6 3/4 40 T 2.0 3.4 0.0 Thru 6 504 3/4 40 T 1.0 5.1 0.0 Side 6 505 3/4 40 T 2.0 9.6 0.0 Thru 4 7 3/4 40 T 6.0 12.2 0.0 BHT 7 506 3/4 40 T 1.0 5.1 0.0 Side 7 8 3/4 40 T 2.0 3.4 0.0 Thru 8 507 3/4 40 T 1.0 5.1 0.0 Side 8 508 3/4 40 T 2.0 9.6 0.0 Thru Start Term Flow psi psi (lbs/min) 750 736 69.0 736 726 138.0 726 703 138.0 703 701 69.0 701 701 23.0 701 701 46.0 701 701 23.0 701 701 23.0 703 701 69.0 701 701 23.0 701 701 46.0 701 701 23.0 701 701 23.0 Calculation based on 70 degree Fahrenheit pre -discharge Pipeline Temperature Nozzle Number 503 504 505 Nominal Pipe Size 3/4 40 T 3/4 40 T 3/4 40 T Nozzle Performance Summary Nozzle Weight (lbs) Code Discharged 2.94 33.4 2.94 33.3 2.94 33.3 Initial Vapor Liquid End of Discharge Time (sec) Time (sec) Time (sec) 1.4 61.5 62.9 1.5 61.4 62.9 1.6 61.3 62.9 1 (Continued) Ansul Incorporated HP CO2 FLOW CALCULATIONS Version 4. 2. 0 Data input file name: C:\Program Files\HP CO2 FLOW\Q6.hp2 Nozzle Performance Summary (Continued) Nozzle Nominal Number Pipe Size 506 3/4 40 T 507 3/4 40 T Nozzle Weight (lbs) Initial Vapor Liquid End of Discharge Code Discharged Time (sec) Time (sec) Time (sec) 2.94 33.4 1.4 61.5 2.94 33.3 1.5 61.4 508 3/4 40 T 2.94 33.3 Total carbon dioxide discharged is 200 lbs Messages 1.6 61.3 Hydraulic calculation was successful. Shortest liquid discharge time for Local Application Nozzle is 61.3 sec Calculation performed on 12/10/2009 2:16:55 PM Calculation by Suppression Systems, Inc. Steven Tuck 4417 Pacific Hwy E Tacoma WA 98424-2611 US Telephone: 253-926-3300 Fax: 253-926-3306 12/10/2009 Time: 2:17:57 PM 2 End of Printout 62.9 62.9 62.9 GENERAL NOTES: 1. ALL DOORS IN THE CLEAN AGENT HAZARD AREA SHALL HAVE DOOR CLOSURES, DOOR SWEEPS AND DOOR SEALS. (BY OTHERS ) 2. THE DISCHARGE TIME OF THE SYSTEM SHALL NOT EXCEED 10 SECOND. THE PROTECTED VOLUME IS TO BE FLOODED AT A 4.2% CONCENTRATION UNLESS OTHERWISE NOTED ON THE SYSTEM DRAWINGS AND HYDRAULIC CALCULATIONS. THE HAZARD AREA SHALL MAINTAIN A 4.2% CONCENTRATION FOR A MINIMUM OF 10 MIN. 3. THE CLEAN AGENT CONTROL PANEL SHALL HAVE BATTERY BACK-UP TO PROVIDE 24 HOURS OF STANDBY OPERATION WITH 5 MINUTES OF ALARM UNLESS NOTED OTHERWISE ON THE DRAWINGS AND THE BATTERY CALCULATIONS. 4. INTERLOCK WIRING AND CONDUIT TO SHUTDOWN THE HVAC SYSTEM AND/OR DAMPERS (IF REQUIRED) WILL BE WIRED BY OTHERS. SUPPRESSION SYSTEMS INC. WILL PROVIDE RELAY CONTACTS LOCATED IN THE CLEAN AGENT CONTROL PANEL. 5. INTERLOCK WIRING AND CONDUIT TO CONNECT TO THE REMOTE FIRE ALARM SYSTEM (IF REQUIRED) SHALL BE PROVIDED BY OTHERS. SUPPRESSION SYSTEMS INC. WILL PROVIDE RELAY CONTACTS LOCATED IN THE CLEAN AGENT CONTROL PANEL. 6. INTERLOCK WIRING AND CONDUIT TO SHUTDOWN EQUIPMENT (IF REQUIRED) SHALL BE PROVIDED BY OTHERS. SUPPRESSION SYSTEMS INC. WILL PROVIDE RELAY CONTACTS LOCATED IN THE CLEAN AGENT CONTROL PANEL. 7. THE CLEAN AGENT HAZARD AREA SHALL BE SEALED TO PREVENT LEAKAGE OF THE AGENT. (BY OTHERS ) SUPPRESSION SYSTEMS INC. WILL PROVIDE GUIDANCE AND/OR SUPERVISION. 8. THE 120VAC CIRCUIT FOR THE CLEAN AGENT CONTROL PANEL SHALL BEA DEDICATED CIRCUIT WITH A LOCK -OUT DEVICE ON THE BREAKER SWITCH TO COMPLY WITH NFPA 72 CURRENT ADDITION. 9. ALL TERMINATION'S IN THE CLEAN AGENT CONTROL PANEL SHALL BE PERFORMED BY SUPPRESSION SYSTEMS INC. CLEAN AGENT PIPING SYSTEM NOTES : 1. REFER TO SYSTEM DRAWINGS AND CALCULATIONS FOR THE LOCATION AND LAYOUT OF THE CLEAN AGENT DISTRIBUTION PIPING SYSTEM. EXAMINE THE CONFIGURATION OF THE PIPING SYSTEM TO ENSURE THE PIPING AND DISCHARGE NOZZLES DO NOT INTERFERE WITH ANY ON SITE PHYSICAL OBSTRUCTIONS WITHIN THE CLEAN AGENT HAZARD AREA BEFORE THE PIPING INSTALLATION BEGINS. SHOULD ANY CONFLICTS OCCUR NOTIFY SUPPRESSION SYSTEMS INC. TO MAKE THE REQUIRED ADJUSTMENTS TO THE SYSTEM DRAWINGS AND HYDRAULIC CALCULATIONS PRIOR TO BEGINNING PIPING INSTALLATION. ANY DEVIATIONS IN THE ROUTING OF THE PIPE NETWORK SHALL BE VERIFIED AND APPROVED BY SUPPRESSION SYSTEMS INC. 2. CLEAN AGENT SUPPRESSION SYSTEM SHALL BE INSTALLED AND TESTED IN ACCORDANCE WITH NFPA 2001 CURRENT ADDITION, AS WELL AS ALL APPLICABLE LOCAL CODES. 3. PIPING MATERIAL MUST CONFORM TO THE REQUIREMENTS OUTLINED IN NFPA 2001 , CURRENT EDITION. SCHEDULE 40 OR SCHEDULE 80 PIPE (BLACK OR GALVANIZED) MUST CONFORM TO ASTM A53 OR A106. ORDINARY CAST IRON PIPE, STEEL PIPE CONFORMING TO ASTM -120, OR NONMETALLIC PIPE SHALL NOT BE PERMITTED TO BE USED. 4. PIPE FITTINGS MUST CONFORM TO THE REQUIREMENTS OUTLINED IN NFPA 2001 , CURRENT EDITION. MALLEABLE IRON FITTINGS (BLACK OR GALVANIZED) SHALL BE 300 LB. CLASS THAT CONFORM TO ASTM SPECIFICATION A-197. 150 LB. CLASS FITTINGS AND ORDINARY CAST IRON FITTINGS ARE NOT PERMITTED. ONLY LISTED GROOVED , THREADED , WELDED OR FLANGED FITTINGS MAY BE USED , PROVIDED THEY CONFORM TO THE ABOVE REQUIREMENTS. HOLE CUT FITTINGS MAY NOT BE USED. 5. ALL PIPE JOINING METHODS SHALL BE IN ACCORDANCE WITH NFPA 2001 CURRENT ADDITION. TEFLON TAPE IS RECOMMENDED AND SHALL BE USED WITH ALL THREADED PIPING CONNECTIONS. THREADED PIPE AND FITTINGS SHALL BE TAPERED IN CONFORMANCE WITH ANSI SPECIFICATION B-20.1. ALL GROOVED PIPING CONNECTIONS SHALL BE BE LUBRICATED PER MANUFACTURERS SPECIFICATIONS. 6. ALL PIPING MUST BE RIGIDLY SUPPORTED BY A COMBINATION OF PIPE HANGERS AND RIGID SUPPORT BRACKETS. PIPE HANGERS ARE USED TO SUPPORT THE " DEAD LOAD " OF THE PIPING SYSTEM AND SHALL BE SPACED AT INTERVALS NOT EXCEEDING 15 FEET. RIGID SUPPORTS ARE REQUIRED TO SUPPORT THE " LIVE LOAD " OF THE PIPING SYSTEM DURING DISCHARGE. RIGID BRACING IS REQUIRED AT EACH DIRECTIONAL CHANGE - 90° ELBOW, TEE AND NOZZLE. ALL 180° NOZZLES REQUIRE BACK -BRACING IN THE OPPOSITE DIRECTION OF THE DISCHARGE PATTERN. EARTHQUAKE BRACING SHALL BE USED WHERE REQUIRED BY LOCAL CODE. REFER TO ANSI 831.1 FOR BRACING REQUIREMENTS. 7. REDUCTIONS IN PIPE SIZE SHALL BE DIRECTLY AFTER A TEE WITH THE TEE BEING THE SAME PIPE SIZE AS THE INLET LINE TO THE TEE. REDUCTIONS IN PIPE SIZE MAY ALSO BE MADE USING A CONCENTRIC BELL REDUCER AFTER A UNION, PROVIDED THE NEXT CHANGE IN DIRECTION (TEE) IS LOCATED A MINIMUM OF 10 PIPE DIAMETERS DOWNSTREAM OF THE CONCENTRIC BELL REDUCER. CONCENTRIC BELL REDUCERS OR CONCENTRIC REDUCING COUPLINGS SHALL BE USED TO MAKE ALL REDUCTIONS IN PIPE SIZE. REDUCING BUSHINGS, WELD -O -LETS AND HOLE CUT FITTINGS SHALL NOT BE PERMITTED. 8. THE SYSTEM SHALL BE INSTALLED IN A PROFESSIONAL MANNER WITH " GOOD COMMERCIAL PRACTICE ". ALL PIPING AND FITTINGS MUST BE REAMED , BLOWN CLEAN AND SWABBED WITH A CLEANING SOLVENT TO REMOVE DIRT , RUST AND OIL. 9. PIPE REDUCTIONS MADE DIRECTLY AFTER A CHANGE IN DIRECTION , WITH THE FITTING BEING THE SAME PIPE SIZE AS THE INLET , SHALL BE MADE USING A COMMON CONCENTRIC BELL REDUCER. REDUCING BUSHINGS ARE NOT ACCEPTABLE ( UNLESS OTHERWISE NOTED ). A MINIMUM OF 10 PIPE DIAMETERS MUST BE MAINTAINED FROM THE CENTER OF THE FITTING TO THE CENTER OF THE NEXT CHANGE IN DIRECTION. 10. WHEN BRACING THE PIPING CARE SHOULD BE TAKEN TO INSURE THE NOZZLE LOCATIONS ARE WITHIN ONE FOOT OF THE LOCATIONS SHOWN ON THE SYSTEM PLANS. CORRECT NOZZLES SHALL BE INSTALLED EXACTLY IN ACCORDANCE WITH THE SYSTEM PLANS AND THE DEFLECTOR SET SCREW SHALL BE IN PLACE DURING A SYSTEM DISCHARGE OR THE AGENT DISTRIBUTION AND THE SYSTEMS ABILITY TO SUPPRESS A FIRE MAY BE ADVERSELY AFFECTED. NOZZLES SHALL BE INSTALLED PERPENDICULAR TO THE CEILING FOR PROPER DISTRIBUTION PATTERNS. 180° NOZZLES SHALL BE ALIGNED WITH THE ORIFICE HOLES ORIENTED PARALLEL TO THE ADJACENT WALLS SO NO DIRECT WALL IMPINGEMENT OF THE AGENT OCCURS. 11. FINAL INSTALLATION ACCEPTANCE SHALL BE IN ACCORDANCE WITH NFPA 2001 CURRENT ADDITION. ELECTRICAL SYSTEM NOTES 1. THE DETECTION AND CONTROLS PORTION OF THE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 70, 72 AND STATE AND LOCAL CODES WHERE APPLICABLE. 2. ALL WIRING FOR THE CLEAN AGENT SUPPRESSION SYSTEM SHALL BE INSTALLED IN MINIMUM OF 1/2" ELECTRICAL METALLIC TUBING (EMT) OR CONDUIT. 3. INITIATING AND RELEASING CIRCUITS SHALL BE INSTALLED N RACEWAYS. ( NFPA 2001 ) 4. AC AND DC CURRENT SHALL BE RUN IN SEPARATE CONDUIT AND BOXES. 5. PAINT ALL J -BOXES AND COVERS RED TO IDENTIFY FIRE ALARM SYSTEM. 6. IDENTIFY EACH COVER WITH POWER LIMITED FIRE ALARM CKT. 7. MAINTAIN 1" SEPARATION BETWEEN ALL POWER LIMITED AND NON POWER LIMITED CIRCUITS. 8. CONTROL SYSTEM SHALL BE INSTALLED AND TESTED IN ACCORDANCE WITH NFPA 72 , AS WELL AS ALL APPLICABLE LOCAL CODES. 9. SMOKE DETECTORS SHALL BE LOCATED NO CLOSER THAN 3 FEET TO AN AIR SUPPLY OUTLET. ALL SMOKE DETECTORS SHALL BE INSTALLED IN AN ACCESSIBLE LOCATION TO ALLOW FUTURE TESTING AND SERVICE. 10. WHEN 17 AMP BATTERIES ARE USED THERE SHALL BE NO PENETRATIONS THROUGH THE BOTTOM OF THE CONTROL PANEL. 11. AIR HANDLING DAMPERS SHALL SHUT DOWN WHEN CLEAN AGENT SYSTEM IS IN THE PRE -DISCHARGE CONDITION. EXCLUSIONS **WORK LISTED BELOW SHALL BE PROVIDED BY OTHERS OR UNDER OTHER SECTIONS OF THE PROJECT.** 1. 120 VAC POWER SUPPLY TO THE CLEAN AGENT CONTROL PANEL. 2. TELEPHONE LINES FOR REMOTE MONITORING. 3. INTERLOCK WIRING AND CONDUIT FOR SHUTDOWN OF HVAC , DAMPERS AND/OR ELECTRIC POWER SUPPLIES , RELAYS , SHUNT TRIP BREAKERS OR OTHER DEVICES. 4. CONNECTION TO LOCAL OR REMOTE FIRE ALARM SYSTEMS OR LISTED CENTRAL ALARM STATION. 5. ALL MATERIALS AND LABOR TO ENSUE THE " AIR -TIGHTNESS " OF THE PROTECTED SPACE(S) AND RESPONSIBILITY FOR THE INTEGRITY OF THE CLEAN AGENT PROTECTED SPACE TO SATISFY THE REQUIREMENTS FOR THE TEN (10) MINUTE RETENTION TIME. SUPPRESSION SYSTEMS INC. MAY PROVIDE ASSISTANCE , BY MEANS OF INSPECTION OF THE SPACE AND MAKING RECOMMENDATIONS ON REMEDIAL ACTIONS THAT MAY BE REQUIRED TO ENSURE ROOM INTEGRITY. DRAWING INDEX : FP- 1 - COVER SHEET, NOTES AND FLOOR PLAN FP- 2 - MACHANICAL DETAILS FP- 3 - ELECTRICAL DETAILS PROJECT DATA APPLICABLE CODES : NFPA 12 CURRENT EDITION NFPA 70 CURRENT EDITION NFPA 72 CURRENT EDITION SCOPE OF WORK ° PROVIDE ANSUL CO2 CLEAN AGENT FIRE SUPPRESSION AT QUENCH TANKS #Q1 AND #Q6, WITH ANSUL DETECTION AND CONTROLS. JORGENSEN FORGE 8531 EAST MARGINAL WAY SOUTH SEATTLE, WA 98108 AHJ: FIRE PERMIT CITY OF TUKWILLA 444 ANDOVER PARK EAST TUKWILLA, WA 98188 PHONE: 206-575-4404 AHJ: ELECTRICAL PERMIT 6300 SOUTHCENTER BLVD. #100 TUKWILLA, WA 98188 PHONE: 206-4337165 CO2 PIPING WAREHOUSE FLOOR I cJ TOP OF TANK FLUID LEVEL Q1 Zto N WAREHOUSE CEILING TOP OF TANK \ts CO2 PIPING WAREHOUSE FLOOR BILL OF MATERIALS ITEM QTY PART No. DESCRIPTION 1 6 426613 100 lb. CARBON DIXOIDE CYLINDER W/ HF ACTUATOR AND CV -98 VALVE 2 6 427082 200 BAR FLEXIBLE DISCHARGE BEND 3 4 40309 1/2" HEADER VENT ASSEMBLY 4 1 40094 1/2" HEADER SAFETY 5 1 40076 3/4" HEADER SAFETY 6 2 40860 1/2" CHECK VALVE 7 2 40852 3/4" CHECK VALVE 8 1 428153 1/2" LOCK OUT VALVE 9 1 428154 3/4" LOCK OUT VALVE 10 2 46250 1/4" PRESSURE SWITCH 11 2 42278 ODORIZER 12 6 426100 TYPE "D" NOZZLE W/ STRAINER ORIFICE CODE 3.0 13 2 426102 SEALED NOZZLE W/ STRAINER ORIFICE CODE 2.0 14 2 41942 MAIN NAME PLATE 15 2 41943 RESERVE NAME PLATE 16 2 70449 MAINTENANCE PLATE 17 2 425309 LEAVE AREA WARNING SIGN 18 2 425310 DONT ENTER WARNING SIGN 19 2 425311 CO2 DISCHARGE WARNING SIGN 20 2 433625 LOCK OUT WARNING SIGN 21 1 CUSTOM CUSTOM BUILT FREE STANDING TWO CYLINDER RACK ASSEMBLY 22 1 CUSTOM CUSTOM BUILT FREE STANDING FOUR CYLINDER RACK ASSEMBLY 23 1 434957 IQ -318 ADDRESSABLE RELEASE PANEL W/ BATTERIES 24 2 428655 DOUBLE ACTION WEATHER PROOF RELEASE STATION 25 2 076494 ABORT SWITCH 26 2 076498 KEYED LOCKOUT SWITCH 27 14 428098 FMM-1 MINI MONITOR MODULES 28 2 428101 FCM-1 INTELLIGENT CONTROL MODULE • 29 2 431526 HORN STROBE 75CD WEATHERPROOF 30 4 013975 325° ALL WEATHER VERTICAL EP HEAT DETECTOR W/ COLLECTOR FLUID LEVEL Q6 N -sys}c►. - 6� ut_ ce»114.,1 54.44-,o•, Mek.16I,.e peen+ addr+essy5le... PrOvi L Wt,rv,.,5 S 5 4SL pee MRA ia-, 1 II'' •-•71:".,0041( breaker hgNdt.¢ c1gc,.� 0� 4ek,cw%ut rA c vc✓ii- Lveak v. fru. 01,er1•. K ,c Y y„t. fU$►WItA FIRE DEPART ii lE FREE STANDING CUSTOM RACK please call: 575-440Z a d give this job 1-005' 0„D a 0a No:IQ' �- - 1-006 -007 and exact address for shut 'ion or restoration approval. IfilledC #2 -008 1 O Without Comments As Noted in Red O Per The Attached Letter These plans have been reviewed.by The Tukwila Fire 'revention Bureau for conformance with current City standards. Acce .tfn�.e is subject to errors and omissions which do not w.it:iorize violations of adopted standards and orcin aces. The responsibility for the adequacy of design tests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will requirsa resubmittal of revised drawings for subsequent approvak Finalacceptance is subject to field test and Inspection b The Tukwila Fire Prevention Bureau. Date: I" By: AV/I BOTTOM OF TRENCH QUENCH TANK ELEVATION SUPPRESSION SYSTEM INC. STANDARD SYMBOL LEGEND ( FOR PART NUMBERS AND QUANTITIES SEE PARTS LIST SHEET FP -1 )(If non standard symbol is used it will be called out on the drawing ) CONTROL PANEL EZI AIR SAMPLING PANEL REMOTE ANNUNCIATOR UNIT HEAT DETECTOR Dl SIREN ca SUPPRESSION MANUAL RELEASE STATION EOM SINGLE HAZARD PANEL MEI AIR SAMPLING POWER SUPPLY EXTENDER PANEL SOLENOID RELEASING MODULE SYSTEM CONTROL UNIT ANALOG LOOP UNIT IONIZATION DETECTOR XXX° HEAT DETECTOR v JUNCTION BOX MAINTENANCE BYPASS SWITCH .«Ea SUPPRESSION ABORT STATION END OF LINE RESISTOR BRO MAIN FIRE ALARM CONTROL PANEL RELAY MODULE EMI ADDRESSABLE OUTPUT MODULE (RELAY) DUCT DETECTOR FIRE ALARM PULL STATION AIR SAMPLING DETECTION PORT MEI AUTOPULSE PANEL Gal SUPERVISED CONTROL MODULE OM?8 ADDRESSABLE OUTPUT MODULE (SIGNAL) OD ELECTRIC ALARM BELL PRE -ACTION SOLENOID AIR SAMPLING DROP DETECTION PORT HIGH LEVEL INTERFACE AIYI MINI MONITOR MODULE AMP ADDRESSABLE MONITOR MODULE WEATHER-PROOF STROBE OT PRE -ACTION TAMPER SWITCH S.S.I. SPECIAL ORDER SIGN IMO SUPPLEMENTAL POWER SUPPLY LEM KEYBOARD DISPLAY UNIT ADDRESSABLE MONITOR MODULE (DUAL) STROBE PRE -ACTION FLOW SWITCH 1-000 COMM. LOOP # AND DEVICE ADDRESS BATTERY CABINET EEO KEYBOARD DISPLAY UNIT (LOCAL) • PHOTOELECTRIC DETECTOR HORN / STROBE El PRE -ACTION LOW AIR SWITCH A1.000 AUDIBLE LOOP # AND DEVICE # 1-022 f f.1-023 1-001 1-002 U NAC #1IV75cd NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the. Inspector prior to commencement of Acceptance Testing of any Flie Alarm and Detection Systems. Failure of test will result in a Re -Inspection Fee and termination of the testing. 1-020 .1-021 -003 -004 THE TWO QUENCH TANKS ARE LOCATED IN THE OPEN AREA OF A LARGER BUILDING APPROXIMATLY 100' APART. SSI SHALL RUN PIPING ALONG THE FLOOR TO THE NORTH WALL WHERE A CUSTOM FREE STANDING RACK THAT SHALL HOUSE THE CYLINDERS AND ALL THE ELECTRICAL EQUIPMENT STANDS. QUENCH TANK FLOOR PLAN ANSUL. SUR:C ESSION SYSTEMS, INC. SPECIAL HAZARD FIRE PROTECTION 4417 PACIFIC HIGHWAY EAST TACOMA, WA 98424-2611 BUS: 253-926-3300 FAX: 253-926-3306 DEC 2 2 2009 Tukwila Fire NO. DATE REVISION BY DATE: e n e A A 4 DRAWN: 12/21 /09 NMR CHECKED: NMR APPROVED BY: SHT PROJECT NAME: JORGENSEN FORGE 8531 EAST MARGINAL WAY SO. / SEATTLE, WA 98108 SCALE: 1/4" = 1'-0" NO. DATE REVISION BY SHEET TITLE: FIRE SUPPRESSION AND DETECTION SYSTEMS COVER SHEET, NOTES AND FLOOR PLANS JOB NUMBER: 1001 FP -1 �/3 UNISTRUT FITTINGS ITEM UNISTRUT NO. DESCRIPTION 1 P1000T SLOTTED CHANNEL, 10' AND 20' LENGHTS 2 P1008 NUT, 3/8", 16 THREADS, W/ SPRING 3 HTHR037 STEEL THREADED ROD, 3/8", 16 THREADS 4 P2863 FLAT PLATE, 3/8" BOLT, 7/16" HOLE 5 P1280 CHANNEL END CAPS (TWO PIECES) 6 P1068 90° ANGLE, 2-1/4" X 1-5/8" 7 P2626 90° ANGLE, 2-1/8" X 2-1/8" 8 P1045 Z -SHAPE, 2-1/8" X 1-5/8" 9 P1769 BRACKET, 5-7/8" X 4-3/4", 6300 IN -LB RATING NOTES: 1. ALL NUTS, BOLTS AND UNISTRUT FITTINGS ARE TO BE SUPPLIED BY THE INSTALLER, AND CAN NOT BE ORDERED THROUGH FIKE PROTECTION SYSTEMS. 2. ALL BRACKETING WITH UNISTRUT FITTINGS ARE SHOWN FOR REFERENCE ONLY, AS ALL INSTALLATIONS WILL VARY WITH LOCATION. 1-1/2" ANGLE IRON OR P1000 UNISTRUT iTO MANIFOLD DISCHARGE BEND ...***.-HF ACTUATOR -CV-98 VALVE ®1 -CUSTOM RACK 0.25" PRESSURE PORT 2.309" 2.925' 1.125" - 18 UNEF PRESSURE OPERATED ACTUATOR CV98 ELECTRIC ACTUATOR 1.25"-1 2.5' 0 8 UNEF - 3.025' 1.125"-18UNEF 0.5" CONDUIT THREADS J BOOSTER ACTUATOR 4.5 2z5 HIX HF ELECTRIC ACTUATOR NOTE: BEND SHOULD NOT BE SEVERE ENOUGH TO KINK BRAIDED HOSE. BRONZE FEMALE SWIVEL ADAPTOR THREADED 1-5/16" 12 N-3 (TO CYLINDER VALVE) CHECK VALVE IBER GASKET MUST BE IN PLACE WHEN ATTACHING TO VALVE BRONZE MALE COUPLING 1/2" NPT CUSTOM CYLINDER RACK ASSEMBLY SINGLE ROW DETAIL SHEET ROCK CEILING MIN. 1 5/8" STRUT STRUT CLAMP CLEAN AGENT PIPE STRUCTURE MIN. 1 5/8" STRUT STRUT CLAMP CLEAN AGENT PIPE CLEAN AGENT PIPE 1 -RAISED FLOOR STRUT CLAMP MIN. 1 5/8" STRUT L STRUCTURE STRUCTURE PIPE MOUNTING DETAIL 3'-0" 15'-0" 11'-0" 8'-0" 1'-0" SINGLE 100 LB. VALVE DETAIL MAIN w cc w w ccd O Q6 HAZARD ACTUATOR DETAILS RATE BY VOLUME CALCULATIONS PER NFPA 12 SECTION 6.5 EDITION 2008 TOTAL AGENT = VOLUME X 0.25 FLOW RATE (LB/MIN/CF) X 1.4 (LIQUID FACTOR) X .5 (MIN. DISCHARGE TIME) HAZARD INFORMATION Q1 - 10' 0 X 3.14 X 4' = 126 CF 126CFX0.25X 1.4X0.5 = 23.0/ 100 = 0.23 = 1 - 100 LB CYLINDER MINIMUM AGENT 23LBS / 2 NOZZLES = 11.5 LBS PER NOZZLE SUPPLIED AGENT 100LBS / 2 NOZZLES = 50 LBS PER NOZZLE MAIN w w MAIN w ec w w cc Q1 HAZARD 20'-0" RATE BY VOLUME CALCULATIONS PER NFPA 12 SECTION 6.5 EDITION 2008 TOTAL AGENT = VOLUME X 0.25 FLOW RATE (LB/MIN/CF) X 1.4 (LIQUID FACTOR) X .5 (MIN. DISCHARGE TIME) HAZARD INFORMATION Q1 - 13' X 15' X 4' = 780 CF 780 CF X 0.25 X 1.4 X 0.5 = 136.5/100 = 1.3 =2-100 LB CYLINDERS MINIMUM AGENT 137LBS / 6 NOZZLES = 22.83 LBS PER NOZZLE SUPPLIED AGENT 200LBS / 6 NOZZLES = 33.33 LBS PER NOZZLE 2'-9" 5'-0" 2'-9" 5'-0" 501 CODE 3.0 , 2'-9" 504 ( CODE 3.0 )� 2'-9" 502 CODE 3.0 505 CODE 3.0 503 ( CODE 3.0 2'-9" 506 ( CODE 3.0 T 502 ( CODE 2.0 TYPICAL INSTALLATION DISCHARGE BEND DETAILS 1/2" LOCKOUT VALVE 1/4" PRESSURE SWITCH TO Q6 HAZARD DORIZER 1/2" HEADER SAFETY 1/2" HEADER VENT ASSEMBLY (TVP. 2) DISCHARGE HOSE (TYP. 2) --- CO2 VALVE ASSMEMBLY (TYP. 2 100 LB CO2 CYLINDER (TYP. 2) V-0" (TYP.) ANGLE INTO HAZARD SEALED NOZZLE 2'-9" 1/2" SHORT NIPPLE (TYP. 5) - 1/2" CHECK VALVE (TYP. 2) - 1/2" X 1'-0" (TYP. 2) 1/2" TEE (TYP. 5) s MAIN IJ w CC w w cc Q6 HAZARD MANAFOLD 4'-0" THESE SPECIFICATIONS ARE TO APPLY TO ALL INSTALLATIONS OF CARBON DIOXIDE FIRE EXTINGUISHER SYSTEMS. NOTE: PIPE SHALL CONFORM TO ASTM SPECIFICATIONS FOR A53 OR A106 PIPE. A120 SHALL NOT BE USED. 1. ALL PIPE UP TO AND INCLUDING 3/4" SIZE TO BE STANDARD WEIGHT GALVANIZED STEEL (SCHEDULE 40). EXCEPT THE MANIFOLD SHALL BE EXTRA HEAVY GALVANIZED STEEL (SCHEDULE 80). 2. ALL PIPE OVER 3/4" SIZE TO BE EXTRA HEAVY GALVANIZED STEEL (SCHEDULE 80) 3. EXTRA HEAVY GALVANIZED MALLEABLE IRON OR DUCTILE IRON FITTINGS SHOULD BE USED THROUGH 2" SIZE; CLASS 300 Ib. AND GALVANIZED FORGED STEEL FITTINGS IN ALL LARGER SIZES. 4. PIPE LENGTHS GIVEN ARE FROM CENTER TO CENTER OF FITTINGS. 5. ALL DIMENSIONS ARE TO BE FIELD CHECKED. ANY DEVIATIONS FROM THE ARRANGEMENT SHOWN WILL REQUIRE COMPLETE REVIEW OF THE NOZZLE AND LINE PRESSURE CALCULATIONS BY THE DESIGNER. 6. REAM, CLEAN, AND BLOW OUT ALL PIPE BEFORE INSTALLING. 7. CYLINDERS AND PIPE TO BE SECURELY BRACKETED ESPECIALLY AT FITTINGS AND NOZZLES. 8. ALL DEAD END PIPE LINES TO BE PROVIDED WITH A 1/2" CAPPED NIPPLE 2" LONG. 9. DETECTOR CABLE TO BE RUN IN 1/2" THINWALL CONDUIT (E.M.T.) 1'-C' (TYP.) ANGLE INTO HAZARD TYPE "D" NOZZLE ip a) co to WEIGH RAIL WEIGH SCALE AND LIFTING RING. (NOT SUPPLIED) 100 Ib. CO2 CYLINDER _ CYLINDER ro FOUNDATION CYLINDER WEIGHING ARRANGEMENT 3/4" LOCKOUT VALVE 1/4" PRESSURE SWITCH 3/4" HEADER SAFETY 3/4" HEADER VENT ASSEMBLY (TYP. 2) DISCHARGE HOSE (TYP. 4) CO2 VALVE ASSMEMBLY (TYP. 4) 100 LB CO2 CYLINDER (TYP. 4) TO Q1 HAZARD ODORIZER - 3/4" SHORT NIPPLE (TYP. 7) - 3/4" CHECK VALVE (TYP. 2) - 3/4" XV -0" (TYP. 2) - 3/4" X 3/4" X 1/2" TEE (TYP. 4; MAIN w w w c w cc w w cc Q1 HAZARD MANAFOLD ANSUL. SUPRZESSION SYSTEMS, INC. SPECIAL HAZARD RRE PROTECTION 4417 PACIFIC HIGHWAY EAST TACOMA, WA 984242611 BUS: 253-926-3300 FAX: 253-926-3306 NO. DATE REVISION BY DATE: 12/21/09 DRAWN: NMR CHECKED: APPROVED BY: SCALE: NO. DATE NMR SHT NOT TO SCALE REVISION BY 6 A PROJECT NAME: JORGENSEN FORGE 8531 EAST MARGINAL WAY SO. / SEATTLE, WA 98108 SHEET TITLE: FIRE SUPPRESSION AND DETECTION SYSTEMS MECHANICAL DETAILS n JOB NUMBER: 1001 FP -2 of/3 A- A+ B- B+ 8 NAC SECURITY SUPV. TB9 ZONE CODS NAC #1 A- A+ B B+ TB7 NAC A- A+ B- B+ A A B B + TB6 NAC TB5 9 9 00 9 9 9 m TB10r" 0B11 ®REC IXMII� Acs EIA -485 I v¢ TERM. NZ NW O � z dND FAULT ENABLE DISABLE #2 #3 #4 TB1 3v C FINEU NC NO C NC NO eeeeee TX RX REF TX RX REF TB12 PRINTER J1 00000 NUP PORT USB A PC/CRT .onEtk J2 )USBB '—"J3 ®®®® TB13 SLC 1 ALARM (TROUBLE 999999C NC NO C NC NO ACTIVE POWER 0 0 PRE- DISCHARGE DISCHARGE 0 ABORT El ACTIVE ACKNOWLEDGE SCROLL DISPLAY 1 Q i 2 W A 1 LOWER CASE E S Z FIRE ALARM f 4 R D X PRE -ALARM SECURITY SUPERVISORY SYSTEM TROUBLE SIGNAL SILENCE 5%1 T F 6. Y G 1 V 7 U H B LISABILW61-11 ACKSILENCE SW5 SW6 SW7 8 J N SYSTEM RESET 9 1 0 K M 10 9 1 P L SPACE JP2 • SIGNALS POINT SILENCED DISABLED DRILL HOLD 2 SECONDS a: Enter 00000000000000000000 00000000000000000000J DETECTOR MODULE OUTPUT BATTERY LEVELS J J5O3 O° J6 LAMP TEST NEXT SELECTION PREVIOUS SELECTION RELAAST ENTRY INCREMENT NUMBER + ( NFS-320 JP1 O-0 O RATE COMPENSATED HEAT DETECTOR (Q1) 7- ABORT STATION MANUAL RELEASE RATE COMPENSATED HEAT DETECTOR (Q6) yl, /- ABORT STATION _/- MANUAL RELEASE T I WEATHERPROOF DIS -CHARGE HORN / STROBE (Q1) n WEATHERPROOF DIS -CHARGE HORN / STROBE (Q6) n 120VAC BY OTHERS FIRE SUPPRESSION RELEASE PANEL WITH BATTERY BACKUP NAC NAC CO2 TANKS 100# CYLINDERS W/ BRACKET SUPPORTS PER MANUFACTURES RECOMMENDATIONS z z 2 UJ U.1 W Q1 w w W 6 DISCHARGE NOZZLES (Q1) --� I 2 DISCHARGE NOZZLES (Q6) z 2 w w W PRESSURE SWITCH (TYP.) /-CONTROL HEAD/SOLENOID (TYP.) AUX POWER MAIN/RESERVE SWITCH UNISTRUT BRACKET KEY -OPERATED 'O'N _ 24VDC LOCK -OUT SWITCH ACTUATOR Ar AV A�IQ Q []1•mr CONDUIT ADAPTER PLATE -- + 0 N 24VDC 3-0 BOX LOCK NUT SENSOR ACTUATOR RELEASE CIRCUIT 'O'N • 'O'N KEY OPERATED LOCKOUT SWITCH WITH MAIN/RESERVE SWITCH WIRING DETAIL THERMAL DETECTOR SURFACE MOUNTING DETAIL DISCHARGE VALVE CEILING gl- ZC21 —I SOL NOID Imo I FROM ZC21 L. , CONTROL RELEASE PANEL MOUNT ALL DEVCES ON THE CUSTOM FRAMING N.O. N$ ZC11 UNIT ZH11 I I NCUNISTRUT NOT TO 720" EXCEED 130.0' (ADA)9�'C!� ae.a El,. I MAX UNIT _ AC11 AK11 I L____1 I KEY OPERATED LOCKOUT SWITCH WIRING DETAIL MAIN / RESERVE SWITCH WIRING DETAIL GENERAL DEVICE ELEVATION HORN/STROBE 3.3K, 1W EOL ,Itimi i i HF ACTUATOR EOL 7 + + 47K 1/2W El 19+ It 0 0 I ti N 1S �( 7 - - - + 1 2 IC' MOMS FMM-101 ' ° e I ORANGE . 00 4 03 FCM-1 IC ,I . + UTD 144- 3 `o ABORT STATION I m f RELEASE STATION PRESSURE SWITCH COIL 5 + ' IC §LC -1IN VIOLET(+) I SLC {+1 IN ,THERMAL DETECTORS B+ A+ B- A- SUPERVISION 'T' MODULE SLC IN (-) , YELLOW (-) I sLc( -)our ' -JOS ® S SLC OUT (+1 SW (+) Our FMM-101 WIRING DETAIL NAC WIRING DETAIL HF ACTUATION WIRING DETAIL PARKING PARKING ENGINEERING MAIN OFFICE PARKING MELT SHOP MACHINE SHOP Q1 AREA OF WORK Q6 FORGE SHOP AREA MAP ANSUL. SUPR2ESSI0N SYSTEMS, INC. SPECIAL HAZARD FIRE PROTECTION 4417 PACIFIC HIGHWAY EAST TACOMA, WA :: 24.2611 BUS: 253-926-3300 NO. DATE REVISION BY DATE: 12/21/09 A DRAWN: NMR CHECKED: NMR APPROVED BY: SHT PROJECT NAME: JORGENSEN FORGE 8531 EAST MARGINAL WAY SO. / SEATTLE, WA 98108 A A SCALE: NOT TO SCALE 4 NO. DATE REVISION BY SHEET TITLE: FIRE SUPPRESSION AND DETECTION SYSTEMS ELECTRICAL DETAILS JOB NUMBER: 1001 FP -3 O1 3