Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 9112 EAST MARGINAL WAY SOUTH - AIRFIELD BUSINESS CENTER BLDG B - PERMITS AND PLANS
9112 EAST MARGINAL WAY SOUTH ASSOCIATED PERMITS D15-0033 D13-334 14-F-008 14-S-062 13-S-080 889103 eg:114(2, IfiE SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** h31 APR 012014 TUai&FIR King Co. Assessor's Tax No.: 51 2.2. 00 ISD Site Address: 9112_ C . MAa.c.iN RL LA'' Suite Number: °I11Z Floor: -- Tenant Name: - New Tenant? ❑ - Yes 21- No Property Owner's Name: Woo° M t= PrO t7WS L I Mailing Address: Pc) tQt7X LS`/ K12KI.NnN 444 59 08',3 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Jour 1111.0-cAlt Day Telephone: 253 - 92(0 - i7- Company Name: PR i \ oT F t rzt Pao i r' c1-1 ur-t Mailing Address: 21o, 7OT=' AN/E E TAcoAA t'4 5842Y City State Zip E-mail Address: 3.Ap...d @. hartit. FA la -e . Coln Fax Number: ?53-922- G/Sv Total number of new/relocated devices or sprinkler heads: V Valuation of Project (contractor's bid price): $ 1/ Sots Scope of Work (please provide detailed information): AriDO s Intl ocJ .. Ser' n l.tf c0 ►ModiCr; (dAt'eA) o C b.. , f op rvt y i.. Wine -NE - PERMIT ine.Ne. PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN 0 UTHORIZED AGENT: Signature: Print Name: Jdl•— DA c c*. Date: 3- 31- Day Telephone: 2S3 - ZZ`'C Plan Permit App.doc 1/2/13 TFD FP Form 8 k FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Airfield Bathrooms 9112 East Marginal Way S Permit No.: 14-S-062 Date: April 7, 2014 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. t • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. i INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 3)lc- 0033 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: j- 1 L►o rra 4EVsLx_icti. Type of Inspe . /L ii-7N/A1 Address: Suite#: (`Z. (=�\ 0/S Contact Person: _ Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: — , Pre -Fire: _ — Pis - Ala /yew 5t/k //nox c))6 Ser v:ce,i fry f i 1 t -c Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector_ . 1,tita. Date: Z 2.6lic Hrs.: / . $100.00 REINSPECTION .FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER / INSPECTION RECORD Retain a copy with permit F' CITY OF TUKWILA FIRE DEPARTMENT TD3— c( V-S—Oo7 PERMIT NUMBERS 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: r 0 usiN•sS �&4n Type of Inspecti <W : (e Y,ia-i Address: Suite #: s if Z A) Contact Pers n: 3r/t__ 1/ g" &Me_ Special Instructions: / Phone No.: Occupancy Type: AApproved per applicable codes. Corrections required prior to approval. COMMENTS: y.�.l.- CevQr- ," -PASS -- Fire Alarm: Hood & Duct: "-- Addeo /1-Keifivr 66 1c4 M 3r/t__ 1/ g" &Me_ Pre -Fire: Permits: Occupancy Type: .. f l -, 2‘.,,1- , Scr1 ,,r 4.s4se_A 1) tN 0RICA_ C k o+rCt of Needs Shift Inspection: y.�.l.- Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:er Date: CA / Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit QO ly-F-oog PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: Alfr id\ 114N4.5) (t,„/).- Type of Inspection: FA- Fr\w\ Address: c 111 �, r W S. Suite #: Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: Sprinklers: Fire Alarm: L /114,,,,,G, \ Hood & Duct: Monitor: Set cuk MA 0... Pre -Fire: Permits: Occupancy Type: Inspector: / 51 \ Date: s --_c _ I C,( Hrs.: / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 7 pf3- i PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: uIGD0ri.e,,,,)0 j Type of Inspection: c -A - Address: q' 1 1 a Suite #: at' eivikiy5 Contact Person: Special Instructions: Permits: Phone No.: Approved per applicable codes. corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: / a IAAfoP 1 y 44 r -e_ 1-eecet S ( r^'o(Cle ,-- {-fie.7io , I- i- ti y 1A-,A,D0,,Ltz N &-7 -ra-kl-oilt6 d t12 ,4"0 ✓ 0 C)A^o kse S i t 14-1--- ; w o +((l 11 A2-64_ 3. E/1- ,\J-ee_Aed ". Co))( -i f. ® co,.00) 14 l'ori_s• k P - 12.0-2 I},i . . Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: /k Date: q/ 2 7// y Hrs.: 1 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD- orW Retain a copy with permit. O PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: Pc\ ax-\, , 1 d Sprinklers: ca ---",4_, sks,'N -e C Type of Inspection: 14- Address: _;,i0 Suite #: Pre -Fire: C 1„Vc; ��� viiS Contact Person: Special Instru ns: Phone No.: DLA pproved per applicable codes. Corrections required prior to approval. COMMENTS: .c,NffiL Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Jk Date: 6//) /3 Hrs.: I $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: 5(422 -' 61SC> Site Address: t 1 Z . 1"`ar J '�l�r; l W U`-'\ Suite Number: Floor: Tenant Name: New Tenant? ❑ - Yes ❑ - No Property Owner's Name: Wcf.A cxleclAou3s Mailing Address: hQ E'S+ ti'1 k J fl(,_( w a LI J i V WB- `EI UCs City i k, State Zip CONTACT PERSON -if there((��are questions about about the submittal. pp "" / ^ C,� Name: MI -�C-1n r►'n CNcQ L� Day Telephone: 5(00 (52- I C)(L) Company Name:0 \ 4 rr P l C- C v (� / C_Dmrn Mailing Address: P. (-)X 3S5C\ G1�� �i(J� j w QI" 98223 City J State Zip E-mail Address: mi -A -Ch Syskerst1Se'Ctct Ol PS (OtY) Fax Number: 3p0—(US2-22 m Total number of new/relocated devices or sprinlder� heads:" Valuation of Project (contractor's bid price): $ A W3 00 Scope of Work (please provide detailed information): TTfSI l 21 ' Eu.J S1 b (1P Ct(m % 1\(e- flA CkC in syS YI . PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. 2 Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUT . ORIZED AGENT: Signature. II ,,,,��,,��111' L� Print Name: I -tea -.0,T Nk() l )� Date: - f - i „ Day Telephone: 520J ( 2 - 06 Plan Permit App.doc 1/2/13 TFD FP Fomi 8 ,f‘ tE WO+n a _x aro 89£9-94Z (9oz) XY! [889-££i (9oZ) 3N0 w 3l1-6 1 ■■•®e.•■■ir■■■■ ■ ■ ■ ■ A : • ., : 17 Without Comments ©As Noted in Red Per The Attached Letter These p!ans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City ;r. ndards. Acceptance is subject to errors and ,:rnissions which do not authorize violations of adopted ;:an Ards and ordinances. The respons*bility for the :, dequacy a design rests totally with the desig%'er. ,additions; c etetions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. ,,.ate: -a (- I `( By: /?Dv ii 1 via L 1 rzi Permit No. t:4 j �^�a+'4. address for Ju`- dovici or reztorattOn lipproval. Chsvi•e. v►e434ktaitaeVp.A 1 Sic+,vis 4,0e a detva L 440•O' w..4 S pati • e►a ,K ��. k+Ao)c lti:4t i4.4os t aS. NOTICE completed, signed, Tukwila Fire Department Pre-test Certificate must be is stinted to the Inspector prior to commencement of Acceptonce Testing of any Fire Alarm and Dei,ect.ion Systems. Failure of test will result in a Re -inspection Fee and iermtnation of the t'"4 `no Fire Alarm Systems SPEC 1 FIRE" A Far t:; ri1 Multi Cs 'liela .44 DESCRIPTION Wheelock's patented Series RSS Strobe Appliances and Series RSSP Strobe Plates have lower current draw and Zero Inrush while maintaining outstanding performance, reliability and cost effectiveness. These versatile appliances will satisfy virtually all requirements for indoor, wall or ceiling mount applications. Strobe options for wall mount models include 15/75, 150, 177 and 185cd or Wheelock's patented Multi -Candela strobe with field selectable candela settings of: 15, 30, 75, or 110cd. Ceiling Mount models are available in 15, 30, 75, 100, 150, and 177cd intensities. All models may be synchronized when used in conjunction with the Wheelock SM, DSM Sync Modules or the PS -12/24-8 Power Supply with Wheelock's Patented Sync Protocol. Synchronized strobes can eliminate possible restrictions on the number of strobes in the field of view. Wheelock's synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy as well as meeting the requirements of NFPA 72. Wheelock's Series RSS Strobes employ a Patented Integral Strobe Mounting Plate that can be mounted to a single gang, double gang, 4" square, 100mm European backboxes or the SHBB surface backbox. If the flush backbox has side or top space between it and the finished wall, the NATP (Notification Appliance Trimplate) may be used. It provides an additional .65" of trim for the Appliance. An attractive cover plate is provided for a clean, finished appearance on all models. The Series RSSP Multi -Candela Strobe Plates are a cost effective way to retrofit required strobe appliances to bells, homs, chimes, multitones or speakers and easily mounts to standard 4" backboxes or for surface mount use with Wheelock's SBL2 surface backbox. For Weatherproof Series RSS See Datatsheet S9004 Copyright 2002 Wheelock, Inc. All rights reserved. Helping People Take Action SERIES RSS & RSSP SINGLE & MULTI-CANDELASTROBES & STROBE PLATES Series RSS Series RSSP Multi -Candela Indicator (bottom of Strobe Lens) Features • Approvals include: UL Standard 1971, New York City (MEA), California State Fire Marshal (CSFM), and Factory Mutual (FM). Pending: Chicago (BFP). • High Candela Approvals: UL Standard 1971, MEA, and CSFM. Pending: FM and BFP. Pending: 150cd & 177cd wall mount CSFM, MEA, FM and BFP. • ADA/NFPA/UFC/ANSI compliant. • Meets OSHA 29 Part 1910.165. • Wall mount models are available with Field Selectable Candela Settings of 15, 30, 75 or 110 cd. (Multi -Candela models) or 15/75, 150, 177 and 185 cd. • Ceiling mount models are available in 15, 30, 75 100, 150 and 177 cd. • Low current draw with temperature compensation to reduce power consumption and wiring costs. • Strobes produce 1 flash per second over the regulated voltage range. • 12 and 24 VDC models with wide UL "Regulated Voltage" using filtered (DC) or unfiltered VRMS input voltage. • Wall Mount or Ceiling Mount models. • Synchronize with Wheelock SM, DSM or PS -12/24-8 Power Supply with Wheelock's built-in sync protocol. • ZERO Inrush above Peak. • Compatible with all Wheelock 2 -Wire products. • Fast installation with IN/OUT screw terminals using #12 to #18 AWG wire. NOTE: All CAUTIONS and WARNINGS are identified by the symbak. . All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes • Strobes are designed to flash at 1 flash per second minimum over the Regulated Voltage Range. Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • Series RSS & RSSP Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32° F to 120° F (0° C to 49° C) and maximum humidity of 93% (± 2%). • "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change, UL used the terminology "Listed Voltage Range". Table 1: Specifications & Ordering Information - Multi -Candela and Single Candela Models - WALL MOUNT Model Order Code Input VoltageVDC Regulated Voltage VDCIFWRge Strobe Candela (CD) Average Current * @ 24 VDC 15cd 30cd 75cd 110cd RSS-24MCW-FR 9400 24 16.0 - 33.0 15/30/75/110 .050 .081 .133 .161 RSS-24MCW-FW 9401 24 16.0 - 33.0 15/30/75/110 .050 .081 .133 .161 RSS-241575W-FR 7471 24 16.0 - 33.0 15 (75 on Axis) .065 RSS-121575W-FR 7476 12 8.0 -17.5 15 (75 on Axis) .170 RSSP-24MCW-FR 9402 24 16.0 - 33.0 15/30/75/110 .050 I .081 I .133 .161 RSSP-241575W-FR 7793 24 16.0 - 33.0 15 (75 on Axis) .065 RSSP-121575W-FR 7798 12 8.0 -17.5 15 (75 on Axis) .170 RSSP-24150W-FR 9478 24 16.0 - 33.0 150 .293 RSSP-24177W-FR 9480 24 16.0 - 33.0 177 .333 RSSP-24185W-FR** 9472 24 16.0 - 33.0 185 - RSS-24150W-FR 9477 24 16.0 - 33.0 150 .293 RSS-24177W-FR 9479 24 16.0 - 33.0 177 .333 RSS-24185W-FR** 8223 24 16.0 - 33.0 185 - Table 2: Specifications & Ordering Information - Single Candela Ceiling Mount Model Order Code Input Voltage VDC Regulated Voltage Range VDC/FWR Strobe Candela Average Current RSS-2415C-FW 7482 24 16.0 - 33.0 15 .072 RSS-2430C-FW 7483 24 16.0 - 33.0 30 .102 RSS-2475C-FW 7484 24 16.0 - 33.0 75 .205 RSS-24100C-FW 7485 24 16.0 - 33.0 100 .238 RSS-24150C-FW 8222 24 16.0 - 33.0 150 .293 RSS-24177C-FW 8230 24 16.0 - 33.0 177 .333 Table 3: Audibles/Speakers for RSSP Strobe Plate Product Series Multitone Appliances AMT, MT Homs AH, NH Motor Bells MB-G6/G10 Speakers ET -1010/1080, E70, ET70 Chimes CH70 * Average Current per actual Wheelock Production Testing at Listed VDC. For Rated Average and Peak current across UL regulated voltage range for both Filtered DC and unfiltered VRMS, see Installation Instructions. **RSS-24185W-FR is for future release. SYNC MODULES / POWER SUPPLY Model Number Order Code Input Voltage (VDC) Average Current (AMPS) @ 24VDC Mounting Options SM -12/24-R" 6369 24 .028 W DSM -12/24-R"" 6374 24 .035 W PS -12/24-8 ""* 8114 120 VAC - - # SM Sync Module is rated for 3.0 amperes @ 24 VDC. ## DSM Sync Module is rated for 3.0 amperes per circuit. The maximum number of interconnected DSM Modules is twenty (20). Refer to Data Sheet S3000 or Installation Instructions (P83123) for SM and P83177 for DSM). ### Refer to Data Sheet S9001 or Installation Instructions P83862 for PS -12/24-8 Power Supply. A, WARNING: CONTACT WHEELOCK FOR THE CURRENT"INSTALLATION INSTRUCTIONS" (P83911) SERIES RSS/RSSP-24MCW, (P84022 AND P84025) SERIES RSS/RSSP SINGLE CANDELA AND "GENERAL INFORMATION" SHEET (P82380) ON THESE PRODUCTS. THESE DOCUMENTS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS, INCLUDING: • TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALL APPLIANCES ON THOSE CIRCUITS. ADDING, REPLACING OR CHANGING APPLIANCES OR CHANGING CANDELA SETTINGS WILL EFFECT CURRENT DRAW. RECALCULATE CURRENT DRAW TO INSURE THAT THE TOTAL AVERAGE CURRENT AND TOTAL PEAK REQUIRED BY ALL APPLIANCES DO NOT EXCEED THE RATED CAPACITY OF THE POWER SOURCE OR FUSES. COMPOSITE FLASH RATE FROM MULTIPLE STROBES WITHIN A PERSON'S FIELD OF VIEW. THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR "REGULATED VOLTAGE RANGE". INSTALLATION OF 110 CANDELA STROBE PRODUCTS IN SLEEPING AREAS. INSTALLATION IN OFFICE AREAS AND OTHER SPECIFICATION AND INSTALLATION ISSUES. USE STROBES ONLY ON CIRCUITS WITH CONTINUOUSLY APPLIED OPERATING VOLTAGE. DO NOT USE STROBES ON CODED OR INTERRUPTED CIRCUITS IN WHICH THE APPLIED VOLTAGE IS CYCLED ON AND OFF AS THE STROBES MAY NOT FLASH. FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. CONDUCTOR SIZE (AWG), LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. Wiring Diagrams* SERIES RSS/RSSP APPLIANCE FROM + PRECEDING _ APPLIANCE, SYNC MODULE, POWER SUPPLY OR FACP TO NEXT + APPLIANCE OR EOLR SERIES RSS/RSSP APPLIANCES SYNCHRONIZED W/ DSM MODULE SINGLE CLASS "A" NAC CIRCUIT DSM STROBE NAC CIRCUIT OUT TROBE NAC CIRCUIT RETURN FROM PRECEDING - STROBE/PLATE MODULE, POWER ASSEMBLY SUPPLY OR FACP AUDIBLE & VISIBLE APPLIANCE OPERATE IN UNISON SE AUINBLE TO NEXT + APPLIANCE OR EOLR STROBE/PLATE ASSEMBLY ;IZI.,IARCE OR +--1r--- MCOL,E POWER SUPPLY OR FACP I 11 Wow AUDIBLE & VISIBLE APPLIANCE STROBE OPERATE INDEPENDENTLY APPLIANCE -- +TONEXT NE oA SERIES RSS/RSSP APPLIANCE SYNCHRONIZED W/SM MODULE SINGLE CLASS "B" NAC CIRCUIT SM SERIES RSS/RSSP APPLIANCES SYNCHRONIZED W/MULTIPLE DSM MODULES F A C P Strobe NAC Cir Strobe NAC Cir DSM #1 DM DSM #2 INSSync rem z DSM #3 DMZsync Sync 0+ 0 DSM Interconnecting wiring shown. Maximum of twenty (20) SERIES RSS/RSSP APPLIANCES SYNCHRONIZED W/ PS -12/24-8 F A C P Serie PS -12/24-8 OUTPUTS 1-4 4 -CLASS .B• OR 2 -CLASS Sanas PS -12,24-8 AS el off" EOLR # For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the PS -12/24-8 Power Supply refer to Installation Instructions P83862. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters' Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). Architects and Engineers Specifications The visual notification appliances shall be Wheelock Series RSS Strobe Appliances or approved equals. The Series RSS shall meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing -Impaired) for Indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). When Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock Series RSS. The Series RSS Strobe shall be of low current design and shall have Zero Inrush. Where wall mount, Multi -Candela appliances are specified, the strobe intensity shall have a minimum of four (4) field selectable settings and shall be rated per UL Standard 1971 for: 15, 30, 75 or 110 candela. The selector switch for selecting the candela shall be tamper resistant and not accessible from the front of the appliance. The 15/ 75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on axis is required (e.g. ADA compliance). For standard ceiling mount applications, the strobe intensity shall be 15, 30, 75, or 100 candela. For high intensity wall mount applications, furnish, RSS-24150W-FR for 150cd applications, RSS-24177W-FR for 177cd applications, and RSS-24185W-FR for 185cd applications. For high intensity ceiling mount applications provide RSS-24150C-FW for 150cd applicaitons or RSS-24177C-FW for 177cd applications. When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or Wheelock's PS -12/24-8 Power Supply with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non -synchronized flash rate. The strobes shall be designed for indoor surface of flush mounting. The Series RSS Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single -gang, double -gang, 4 -inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. An attaching cover plate shall be provided to give the Appliance and attractive appearance. The Appliance shall not have any mounting holes or screw heads visible when the installation is completed. The Series RSSP Multi -Candela or single candela Strobe Plate shall mount to either a standard 4 inch square backbox for flush mounting, or the Wheelock SBL2 backbox for surface mounting. All notification appliances shall be backward compatible. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock, Inc. standard terms and conditions. pecincarions ana uraenng ►nrormauon Model Order Code Wall Mount Ceiling Mount Non- Sync Sync w/ SM,DSM or PS -12/24-8 Strobe Candela 24 VDC 12 11# VDC Model Color RED # Model Color WHITE Mounting Options**"' RSS-24MCW-FR 9400 X - X X 15/30/75/110 X X B,D,E,F,G,H,J,N,O,R,X RSS-241575W-FR 7471 X - X X 15 (75 on Axis) X - X - B,D,E,F,G,H,J,N,O,R,X RSS-121575W-FR 7476 X - X X 15 (75 on Axis) - X X - B,D,E,F,G,H,J,N,O,R,X RSS-2415C-FW 7482 - X X X 15 X - - X B,D,E,F,G,H,J,N,O,R,X RSS-2430C-FW 7483 - X X X 30 X - - X B,D,E,F,G,H,J,N,O,R,X RSS-2475C-FW 7484 - X X X 75 X - - X B,D,E,F,G,H,J,N,O,R,X RSS-24100C-FW 7485 - X X X 100 X - - X B,D,E,F,G,H,J,N,O,R,X RSSWP-2475W-FR* 9013 X - X X 75 @ -31°F X - X - B,D,E,F,G,H,J,N,O,R,X RSSP-121575W-FR 7798 X - X X 15 (75 on Axis) - X X - D,E,Z RSSP-24MCW-FR 9402 X - X X 15/30/75/110 X - X - D,E,Z RSSP-241575W-FR 7793 X - X X 15 (75 on Axis) - - X - D,E,Z RSSP-24150W-FR 9478 X X X 150 X X B,D,E,F,G,H,J,N,O,R,X RSSP-24177W-FR 9480 X X X 177 X X B,D,E,F,G,H,J,N,O,R,X RSSP-24185W-FR** 9472 X X X 185 X X B,D,E,F,G,H,J,N,O,R,X RSS-24150C-FW 8222 - X X X 150 X - - X B,D,E,F,G,H,J,N,O,R,X RSS-24177C-FW 8230 - X X X 177 X - - X B,D,E,F,G,H,J,N,O,R,X RSS-24150W-FR 9477 X X X 150 X X B,D,E,F,G,H,J,N,O,R,X RSS-24177W-FR 9479 X X X 177 X X B,D,E,F,G,H,J,N,O,R,X RSS-24185W-FR** 8223 X - X X 185 X - X - B,D,E,F,G,H,J,N,O,R,X # Models are available in either Red or White. Call Customer Service for Order Code & Delivery. *For Weatherproof Series RSS Strobe specifications see data sheet S9004. **RSS-24185W-FR and RSSP-24185W-FR are for future release. ***Refer to data sheet S7000 for mounting options. WE SUPPORT AND ENCOURAGE NICET CERTIFICATION 3 YEAR WARRANTY Made in USA NATIONAL SALES OFFICE 1-800-631-2148 Canada 800 397-5777 E-mail: Info@wheelockinc.com httn://www.wheelockinc.com 1VMM Member Distributed By: WHEELOCK, INC. • 273 BRANCHPORT AVE • LONG BRANCH, N.J. 07740.732-222-6880 • FAX: 732-222-2588 S0410 07/02 cri -J — 4w- nw. 1•- < c.) Laa (-) C.3 Ca, 0 ') as:C ce •"— a a. 000 1. v, .C1 0 • . 1 (1) r Zt]. • •— cts77; C.) • 0 ,„ U; • 4-1 c • r • . . ) .e5 a.) 7-2 . - •tf, < ; •— •.:•: • ••"1 .." ••• ••• • •••• • I. • r% • ••: ( • . 3 CI • • , :1 ft; bfl.r••$•-' 4;4 c c .1)•2.) es - (13 r— • —•• ;-;c • mon .13 0 r— tri ...- a) 4) a) 5 E AREA OF WORK I L 1:1 1:) 1.1 L IE) OPEN OFFICE ISI ISI I ISI 1 10- � 1 1 1 1 1 1 1 1 N n (E) SHOP ISP PARTIAL FLOOR PLAN SCALE: 1/8•=1'-0• IEi OFFICE ISI (E) OFFICE C. ` ..o E ❑ Without Comments ❑ As Noted in Red C' Per The Attached Letter .ese plans have been reviewed by The Tukwila Fire .-!-vention Bureau fOr conformance is subject to ith errors current City errors and +=ndards. Acceptance ,±fissions which do not authorize violations of adopted :A !ndards and ordinances. The responsibility for the -, iquacy of design rests totally with the designer. °?:161tions, deletions or revisions to these drawings after �,,.rr gate will void this acceptance and will require a cosubmittai of revised drawings for subsequent approval. Final acceptance is subject to -field test and inspection by ti -ie Tukwila Fire Prevention Bureau. LI -7-I �-� By: M .2 I Date: TUKWILA FIRE DEPARTMENT Please call 206-575.4407 and give this FirePermit ;o. � and exact address for shut- down or restoration approval. SCOPE OF WORK .1. ADD AND RELOCATE SPRINKLERS FOR NEW BATHROOMS. GENERAL NOTES 1. --- EXISTING FIRE SPRINKLER PIPE. 2. lel EXISTING SPRINKLERS IN CEILING TO BE REMAIN. 3. NEW HANGERS TO BE 3/811 EYELETS W/3/8"x21/2" LAG. AREA OF WORK KEY PLAN SCALE: NTS HANGER LEGEND A "U" HOOK B COACH SCREW ROD D BM. CLAMP W/ "STRAP E EYELET F FLUSH SHELL G CEILING FLANGE H SIDE BEAM BRACKET K SHORT CLIP M ALL THREAD ROD N TOGGLE NUT P POWDER DRIVEN STUD R EXPANSION BOLT S PIPE SPIKE T U V W X Y Z STATE CERTIFICATION SPRINKLER LEGEND WASHINGTON STATE PIM PROTECTION SPRINKLER SYSTEMS John Christian Dacca 1150-0409-C Level 3 Patriot Fire Protection, Inc. PA Th i PO F Sign* ur. I A o ce Y � i SPRINKLER ORIFICE SIZES AND TYPE 1- 1— z z w aa. z • Isi t-0 o a 11 12 5 3 7 1 SPRAY 16 8 16 2 0 0 1/2" 1" I3 T 17 32 SPRAY 3 ■ 1" Expires 12/31/14 1 12 I 8 16 2 SIDEWALL 4 1/2" 1" 1" 1 2 DRY TYPE 1" • 1" 2 - WAY EARTHQUAKE BRACE 1 4 - WAY EARTHQUAKE BRACE TEMP RATING n STRUCTURE TO CENTER j� UNE OF PIPE IN INCHES FITTING LEGEND P PIPE -O -LET 0 0 EgE 165° 212° 286° 350° 500° z Z Ft* < WM 0 W % a 0 —J 0 to 0 2 w0 0.. 0 /2" 1" 1" /2" 1" 1/2" 1" 1/2" F PLAIN END FIT FITTING APPROVAL REQUIRED SN GROOVED SHAPED NIPPLE TUKWILA TSN THREADED SHAPED NIPPLE SPRINKLER HEADS USED SYM MANUF MODEL TYPE THREAD SIZE ORIFICE SIZE HEAD FINISH ESCUTCH FINISH TEMP QTY 0 RELIABLE G5-56 CONCEALER 1/2 1/2 BRONZE WHITE 155 4 TOTAL 4 QUALITY CONTROL BY DATE APPROVED FOR FABRICATION BY DATE GENERAL NOTES 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL LISTED OR FM APPROVED. 2. PIPING DIMENSIONS ARE CENTER TO CENTER EXCEPT RISERS AND DIMENSIONS SHOWN THUSLY (1-6) WHICH ARE END TO END. 3. EARTHQUAKE BRACING SHALL BE PROVIDED IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, APPLICABLE EDITION 4. PIPE HANGERS AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, APPLICABLE EDITION. 5. PIPING SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, APPLICABLE EDITION 6. JOINING OF PIPE AND FITTINGS, THREADED & WELDED, SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET NO. 13, APPLICABLE EDITION. 7. OWNER TO PROVIDE ADEQUATE HEAT IN AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM TO PREVENT WATER IN PIPES FROM FREEZING. 8. ALL WIRING OF ELECTRICAL DEVICES (IF REQUIRED) TO BE PROVIDED BY OTHERS 9. PAINTING OF PIPE & EQUIPMENT (IF REQUIRED) TO BE PROVIDED BY OTHERS 10. FURRING OF PIPE & EQUIPMENT (IF REQUIRED) TO BE PROVIDED BY OTHERS DESIGN CRITERIA 1. DESIGNED PER NFPA 13 AND CITY OF TUKWILA PIPE NOTES 1. ALL NEW PIPE TO BE SCH 40. REVISIONS NO DATE BY DESCRIPTION CONTRACT WITH: TCL PARTNERS 16000 MILL CREEK BLVD MILL CREEK, WA 98012 PROJECT NAME: AIRFIELD BATHROOMS 9112 E MARGINAL WAY S. SEATTLE, WA ATRIOT FIRE TACOMA, DESIGNER DATE JOB NO. 1 1 INC. WA 98424 JOHN DACCA I SHEET 1 OF 1 2707 70TH AVENUE EAST 3-31-14 12-16538 PATRIFP099CF WWW.PATRIDTFIRE.CDM johnd®potriotfire.com TEL: (253) 926-2290 FAX: (253) 922-6150 FP1