Loading...
HomeMy WebLinkAboutPP - 1011 ANDOVER PARK EAST - PRINTING CONTROL SERVICES - PERMITS AND PLANS1011 ANDOVER PARK EAST ASSOCIATED PERMITS 12-F-050 4410% CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Print Form Date application n accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Pi **PLEASE PRINT** PAID MAR 13 20' WILA FIRE SITE LOCATION 2623049019 262304-9019 King Co. Assessor's Tax No.: Lb Ea 1011 Andover Pk E Bldg B Site Address: Suite Number: Floor: Printing Control Tenant Name: New Tenant? Q- Yes - No M3 Business Center Property Owner's Name: Same As site Mailing Address: CONTACT PERSON -if there are questions about the submittal. Name:JENNIFER BURGESS/NOTHWEST PERMIT -AGENT Company Name:ADT SECURITY SERVICES City State Zip Day Telephone:206-774-9499 Mailing Address:11824 NORTH CREEK PKWY N # 105, BOTHELL WA 98011 City State Zip E-mail Address: Fax Number:888-400-0383 jennifer@nwpermit.com ZUU9 Valuation of Project (contractor's bid price): $_ Scope of Work (please pmvide detailed information):Scope of work is to replace the existing Fire Panel on an addressable Fire Panel. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR A ORIZED AGENT: Signature: Date:03/13/2012 Carol StickPrint Name: Day Telephone: Plan Permit Ann.dnc 5/14/10 TPD FP Form R Installation Scope of Work The scope of work is a description of the project and services to be provided. It is a short narrative to include design brief, deliverables both products and services, and project objectives; I.e., "what are we trying to accomplish for the customer?" SCOPE OF WORK Contact Information: Nancy Charpentier (206) 575-4114 System Operation: Per the AHJ in Tukwila, it is required that this system be upgraded to an addressalbe system. There will be a control panel replacement to allow for addressability. A smoke alarem to be installed at the panel location. The job also includes wiring the additional duct detector back to the new control panel. Installing addressable monitoring modules to the existing and new circuits. Tech should also remove the two control units that are hanging from the ceiling and terminte the wires in a 4-S box at the ceiling. Site Conditions: A lift will be required in the print shop area to reach the duct detector and to make the wire run back to the panel location. Existing Equipment: There is one new duct detector to be connected, and the other existing detectors will remain. Monitoring modules will be installed for the existing equipment. Customer Expectations: Work to be completed to meet local fire code. Customer Responsibilities / ADT Exclusions: To make sure on the scheduled date that the work area is clear and there is room to operate a scissor lift. Documentation Needs: Fire submission packet will be completed. Enhanced Job Details: System Type: Product Family: Construction Complexity: Network Integration: FA Unimode 9050 Exist.Bldg-New system No network integration Page 4 of 6 03/12/2012 8Flre•LITeALarms MS-9050UD Battery Calculation Regulated Load in Standby Device Type Number of Devices Current (Amps) Total Current (Amps) Main Circuit Board 1 x 0.120000 = 0.120000 4XTMF 0 x 0.005000 = IPDACT-2 0 x 0.093000 = IPDACT-2/2UD 0 x 0.098000 = 4 -Wire Smoke Detectors' 0 x 0.000000 = Power Supervision Relays ` 0 x 0.025000 = ANN -80 (-W) 0 x 0.015000 = ANN-(R)LED 1 x 0.028000 = 0.028000 ANN -I/O 0 x 0.035000 = ANN -I/O LEDs 0 x 0.000000 = ANN-S/PG 0 x 0.045000 = ANN-RLY 0 x 0.015000 = Addressable Devices BEAM355 and BEAM355S 0 x 0.002000 = BEAM 1224 0 x 0.017000 = CP355 1 x 0.000300 = 0.000300 SD355 0 x 0.000300 = SD355T 0 x 0.000300 = AD355 0 x 0.000300 = H355 0 x 0.000300 = H355R 0 x 0.000300 = H355HT 0 x 0.000300 = D350P 0 x 0.000300 = D35ORP 0 x 0.000300 = D355PL 0 x 0.000300 = MMF-300 5 x 0.000400 = 0.002000 MMF-300-10 0 x 0.003500 = MDF -300 0 x 0.000750 = MMF-301 0 x 0.000375 = MMF-302 0 x 0.000270 = MMF-302-6 0 x 0.002000 = BG-12LX 0 x 0.000230 = CMF -300 0 x 0.000390 = CMF -300-6 0 x 0.002250 = CRF -300 0 x 0.000270 = CRF -300-6 0 x 0.001450 = 1300 0 x 0.000400 = 8501 BH & B501 BHT a 0 x 0.001000 = B224RB Relay Base 0 x 0.000500 = B224B1 Isolator Base 0 x 0.000450 = B200SR Sounder Base 0 x 0.000500 = Current Draw from TB3 - EIA -485 0.000000 4 Total Standby Load 0.150300 Notes: 1) Refer to the Device Compatibility Document for standby current 2) Must use compatible listed Power Supervision Relay 3) Maximum alarm current for each sounder base is 0.015 amps which must be supplied by aux. 24VDC source. 4) Total current draw listed cannot exceed 2.7 amps Page 1 of 3 8Flre•LITeALarrns MS-9050UD Battery Calculation Regulated Load in ALARM Device Type Number of Devices Current (Amps) Total Current (Amps) Main Circuit Board 1 x 0.200000 = 0.200000 4XTMF ' 0 x 0.011000 = IPDACT-2 0 x 0.136000 = IPDACT-2/2UD 0 x 0.155000 = 4 -Wire Smoke Detectors 0 x 0.000000 = Power Supervision Relays 0 x 0.000000 = ANN -80 (-W) 0 x 0.040000 = ANN-(R)LED 1 x 0.068000 = 0.068000 ANN -I/O 0 x 0.200000 = ANN -I/O LEDs 0 x 0.010000 = ANN-S/PG 0 x 0.045000 = ANN-RLY 0 x 0.075000 ALL Addressable Devices - Maximum draw 1 x 0.400000 = 0.400000 NAC #1 ` 0 x 0.000000 = NAC #2 0 x 0.000000 = Current Draw from TB3 - EIA -485 0.000000 = 3Total Alarm Load 0.668000 Notes: 1) If using the Reverse Polarity Alarm output, add 0.005 amps; if using the Reverse Polarity Trouble output, add another 0.005 amps. 2) Current limitations for NAC circuits TB1 is 2.5 amps per circuit 3) Total alarm current cannot exceed 2.7 amps Page 2 of 3 ®FiretireALarms MS-9050UD Battery Calculation Note 1: You can edit all current draws and are fully responsible for verifying these calculations. Note 2: You only need to make entries in the yellow cells Calculation in Total Sheet Use the total standby and alarm load currents calculated in tables A -2A and A -2B for the following battery calculations Required Standby Time in Hours (24 or 60 Hrs.) Standby Load Current (Amps) 0.150300 x 24 = 3.607 AH Required Alarm Time in Hours (5 minutes = 0.084) Alarm Load Current (Amps) 0.668000 x 0.084 = 0.056 AH Total Current Load 3.663 AH Multiply by the Derating Factor 1.2 = x 1.20 Total Ampere Hours Required 4.396 AH The MS-9050UD can charge this size battery The batteries can be stored in the cabinet Current Draw Check NAC#1 current is within the limitations of the circuit. NAC#2 current is within the limitations of the circuit. MS-9050UD current draw: The required output current is within the panel's limitations Page 3 of 3 r —4 n1 r , r— + r r r -' ----- r--- •_ • 0 0 44 tk- -mow Ll. . Without Comments As Noted in Red Per The Attached Letter These plans have b=sin reviewed by The Tukwila Fire Prevention Bureau ter ormalce w.tn current City stcndards. Accet.t.cr" rs ..ublec. to errors and oir ssions when co r... LA. „000r+ze violations of adopted standards anu o. d; .anc''S The resdon ibility for the adNuacy of design 'Is:, totally with the designer. Additions, deletion; o- .0 fss:CnS to These drawings after this date will void mss -eptau e and will require a resubmittal of revised drawings for subsea ent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. I Date: t (-1 Al"'"�- By: "e1! ih:4-i 4- •S ett,ato be F0'1' 4d dye ss4Sk (t405 a+ C -e t v t 5 L, 6rui,Lt. k .Lk ackr. r 01. ,A,Lt, CYCv.4 ' N O TCE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and t Fminatior, of the::=;c'''ti �a. TL1 arIL"\ FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. and exact aridness for shut- t. hutt. or resto ati n approvai.