FIRE PROTECTION SYSTEMS PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Pi
**PLEASE PRINT**
PAID
MAR 13 20'
WILA FIRE
SITE LOCATION 2623049019 262304-9019
King Co. Assessor's Tax No.:
Lb Ea
1011 Andover Pk E Bldg B
Site Address: Suite Number: Floor:
Printing Control
Tenant Name: New Tenant? Q- Yes - No
M3 Business Center
Property Owner's Name:
Same As site
Mailing Address:
CONTACT PERSON -if there are questions about the submittal.
Name:JENNIFER BURGESS/NOTHWEST PERMIT -AGENT
Company Name:ADT SECURITY SERVICES
City
State Zip
Day Telephone:206-774-9499
Mailing Address:11824 NORTH CREEK PKWY N # 105, BOTHELL WA 98011
City State Zip
E-mail Address: Fax Number:888-400-0383
jennifer@nwpermit.com
ZUU9
Valuation of Project (contractor's bid price): $_
Scope of Work (please pmvide detailed information):Scope of work is to replace the existing Fire Panel
on an addressable Fire Panel.
PERMIT APPLICATION NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules.
Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit
is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or
abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in
writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE
UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY
FOR THIS PERMIT.
BUILDING OWNER OR A ORIZED AGENT:
Signature: Date:03/13/2012
Carol StickPrint Name: Day Telephone:
Plan Permit Ann.dnc
5/14/10 TPD FP Form R
Installation Scope of Work
The scope of work is a description of the project and services to be provided. It is a short narrative to include design brief, deliverables both
products and services, and project objectives; I.e., "what are we trying to accomplish for the customer?"
SCOPE OF WORK
Contact Information:
Nancy Charpentier (206) 575-4114
System Operation:
Per the AHJ in Tukwila, it is required that this system be upgraded to an addressalbe system. There will be a control panel replacement to allow for
addressability. A smoke alarem to be installed at the panel location. The job also includes wiring the additional duct detector back to the new
control panel. Installing addressable monitoring modules to the existing and new circuits. Tech should also remove the two control units that are
hanging from the ceiling and terminte the wires in a 4-S box at the ceiling.
Site Conditions:
A lift will be required in the print shop area to reach the duct detector and to make the wire run back to the panel location.
Existing Equipment:
There is one new duct detector to be connected, and the other existing detectors will remain. Monitoring modules will be installed for the existing
equipment.
Customer Expectations:
Work to be completed to meet local fire code.
Customer Responsibilities / ADT Exclusions:
To make sure on the scheduled date that the work area is clear and there is room to operate a scissor lift.
Documentation Needs:
Fire submission packet will be completed.
Enhanced Job Details:
System Type:
Product Family:
Construction Complexity:
Network Integration:
FA
Unimode 9050
Exist.Bldg-New system
No network integration
Page 4 of 6 03/12/2012
8Flre•LITeALarms MS-9050UD Battery Calculation
Regulated Load in Standby
Device Type
Number of
Devices
Current (Amps)
Total Current
(Amps)
Main Circuit Board
1
x
0.120000
=
0.120000
4XTMF
0
x
0.005000
=
IPDACT-2
0
x
0.093000
=
IPDACT-2/2UD
0
x
0.098000
=
4 -Wire Smoke Detectors'
0
x
0.000000
=
Power Supervision Relays `
0
x
0.025000
=
ANN -80 (-W)
0
x
0.015000
=
ANN-(R)LED
1
x
0.028000
=
0.028000
ANN -I/O
0
x
0.035000
=
ANN -I/O LEDs
0
x
0.000000
=
ANN-S/PG
0
x
0.045000
=
ANN-RLY
0
x
0.015000
=
Addressable Devices
BEAM355 and BEAM355S
0
x
0.002000
=
BEAM 1224
0
x
0.017000
=
CP355
1
x
0.000300
=
0.000300
SD355
0
x
0.000300
=
SD355T
0
x
0.000300
=
AD355
0
x
0.000300
=
H355
0
x
0.000300
=
H355R
0
x
0.000300
=
H355HT
0
x
0.000300
=
D350P
0
x
0.000300
=
D35ORP
0
x
0.000300
=
D355PL
0
x
0.000300
=
MMF-300
5
x
0.000400
=
0.002000
MMF-300-10
0
x
0.003500
=
MDF -300
0
x
0.000750
=
MMF-301
0
x
0.000375
=
MMF-302
0
x
0.000270
=
MMF-302-6
0
x
0.002000
=
BG-12LX
0
x
0.000230
=
CMF -300
0
x
0.000390
=
CMF -300-6
0
x
0.002250
=
CRF -300
0
x
0.000270
=
CRF -300-6
0
x
0.001450
=
1300
0
x
0.000400
=
8501 BH & B501 BHT a
0
x
0.001000
=
B224RB Relay Base
0
x
0.000500
=
B224B1 Isolator Base
0
x
0.000450
=
B200SR Sounder Base
0
x
0.000500
=
Current Draw from TB3 - EIA -485
0.000000
4
Total Standby Load
0.150300
Notes:
1) Refer to the Device Compatibility Document for standby current
2) Must use compatible listed Power Supervision Relay
3) Maximum alarm current for each sounder base is 0.015 amps which must be supplied by aux. 24VDC
source.
4) Total current draw listed cannot exceed 2.7 amps
Page 1 of 3
8Flre•LITeALarrns MS-9050UD Battery Calculation
Regulated Load in ALARM
Device Type
Number of
Devices
Current (Amps)
Total Current
(Amps)
Main Circuit Board
1
x
0.200000
=
0.200000
4XTMF '
0
x
0.011000
=
IPDACT-2
0
x
0.136000
=
IPDACT-2/2UD
0
x
0.155000
=
4 -Wire Smoke Detectors
0
x
0.000000
=
Power Supervision Relays
0
x
0.000000
=
ANN -80 (-W)
0
x
0.040000
=
ANN-(R)LED
1
x
0.068000
=
0.068000
ANN -I/O
0
x
0.200000
=
ANN -I/O LEDs
0
x
0.010000
=
ANN-S/PG
0
x
0.045000
=
ANN-RLY
0
x
0.075000
ALL Addressable Devices - Maximum draw
1
x
0.400000
=
0.400000
NAC #1 `
0
x
0.000000
=
NAC #2
0
x
0.000000
=
Current Draw from TB3 - EIA -485
0.000000
=
3Total Alarm Load
0.668000
Notes:
1) If using the Reverse Polarity Alarm output, add 0.005 amps; if using the Reverse Polarity Trouble output,
add another 0.005 amps.
2) Current limitations for NAC circuits TB1 is 2.5 amps per circuit
3) Total alarm current cannot exceed 2.7 amps
Page 2 of 3
®FiretireALarms MS-9050UD Battery Calculation
Note 1: You can edit all current draws and are fully responsible for verifying these calculations.
Note 2: You only need to make entries in the yellow cells
Calculation in Total Sheet
Use the total standby and alarm load currents calculated in tables A -2A and A -2B for the following battery
calculations
Required Standby Time in Hours
(24 or 60 Hrs.)
Standby Load Current (Amps) 0.150300 x
24 = 3.607 AH
Required Alarm Time in Hours
(5 minutes = 0.084)
Alarm Load Current (Amps) 0.668000 x
0.084 =
0.056 AH
Total Current Load
3.663 AH
Multiply by the Derating Factor
1.2 =
x 1.20
Total Ampere Hours Required
4.396 AH
The MS-9050UD can charge this size battery
The batteries can be stored in the cabinet
Current Draw Check
NAC#1 current is within the limitations of the circuit.
NAC#2 current is within the limitations of the circuit.
MS-9050UD current draw:
The required output current is within the panel's limitations
Page 3 of 3
r —4 n1 r ,
r— + r r
r
-' ----- r--- •_
•
0
0
44
tk- -mow Ll. .
Without Comments
As Noted in Red
Per The Attached Letter
These plans have b=sin reviewed by The Tukwila Fire
Prevention Bureau ter ormalce w.tn current City
stcndards. Accet.t.cr" rs ..ublec. to errors and
oir ssions when co r... LA. „000r+ze violations of adopted
standards anu o. d; .anc''S The resdon ibility for the
adNuacy of design 'Is:, totally with the designer.
Additions, deletion; o- .0 fss:CnS to These drawings after
this date will void mss -eptau e and will require a
resubmittal of revised drawings for subsea ent approval.
Final acceptance is subject to field test and inspection by
The Tukwila Fire Prevention Bureau.
I
Date: t (-1 Al"'"�- By:
"e1! ih:4-i 4- •S ett,ato be F0'1' 4d dye ss4Sk
(t405 a+ C -e t v t 5 L,
6rui,Lt. k .Lk ackr. r 01. ,A,Lt,
CYCv.4 '
N O TCE
A completed, signed, Tukwila
Fire Department Pre-test
Certificate must be presented
to the Inspector prior to
commencement of Acceptance
Testing of any Fire Alarm
and Detection Systems.
Failure of test will result
in a Re -inspection Fee and
t Fminatior, of the::=;c'''ti �a.
TL1 arIL"\ FIRE DEPARTMENT
Please call 206-575-4407 and
give this Fire Permit No.
and exact aridness for shut-
t.
hutt. or resto ati n approvai.