HomeMy WebLinkAboutPP - 1089 ANDOVER PARK EAST - SUN STAR - PERMITS AND PLANS1089 ANDOVER PARK EAST
ASSOCIATED PERMITS
14-S-159
SITE LOCATION
CITY OF TUKWILA
FIRE MARSHAL'S OFFICE
206-575-4407
FIRE PROTECTION SYSTEMS PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
**PLEASE PRINT**
(� �� King Co. Assessor's Tax No.:
Site Address: lO 3 LuF�oy» I`�2 �= ►T� J Suite Number: Floor:
Tenant Name: T7a- F a
New Tenant? ❑ - Yes ❑ - No
Property Owner's Name:
Mailing Address:
City State Zip
CONTACT PERSON -if there are questions about the submittal.
Name: w C -1'R l 1-1 1�'rt2� tv\
Company Name:
E ke.co Ft t
Day Telephone: 2S 3 (o6 ,12_t.'1
Mailing Address: ICUZL C2' . i'ti2 te-V__13 0-3 (1 i.< 14A -21301Z VA-- %iZ5
City State Zip
E-mail Address: Vet' IQ-tc t ci 1 tie- Fax Fax Number: Z s e' k S 7- z31Z _
``-1
Total number of new/relocated devices or sprinkler heads: t `
Valuation of Project (contractor's bid price): $ 2 7 51,1 .du
Scope of Work (please provide detailed information): A
'A 44.1 SP2t4-0 ue
(N 44,te- co_0(€- -
PERMIT APPLICATION NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revisron by the Fire Marshal to comply with current fee schedules.
Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit
is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or
abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in
writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE
UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY
FOR THIS PERMIT.
BUILDING 4OWN R OR AUTHOJ2IZ A NT:-Z1S/I & '
Signature:
Print Name: Jt ? 73-A lit 6l S 1 _ON.1 Day Telephone:
Plan Permit App.doc 6/4/14 TFD FP Form 8
Date: % Z 3 4-
2 S3 - S-7 —Za
FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS
Project Name: Sunstar Foods
1089 Andover Park East
Permit No.: 14-S-159
Date: July 29, 2014
Reviewer:
Al Metzler
Fire Protection Project Coordinator
(206) 575-4407 option # 2 (Inspection Requests)
(206) 971-8718 (Plan Review Questions)
• Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross
mains, and branch lines 2.5" and larger. Bracing is provided for the last length of
pipe but within 6' of the end of a feed or cross main. Bracing is required unless
all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for
any size pipe, 9.3.5.3.
• Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4
exceptions, 9.3.4.
• Longitudinal sway bracing is a maximum of 80' for mains and cross mains and
within 40 ' of the end of the line, 9.3.5.4.
• Provide lateral and longitudinal bracing for changes in pipe direction per section
9.3.5.11.2 for pipe size 2'/2 inches and larger.
• Restrain branch lines at the end sprinkler of each line, restrain against vertical
and lateral movement, 9.3.6.3.
• Restraints for branch lines shall be at intervals per table 9.3.6.4 and section
9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6.
• Comply with ASCE 7-05, section 13.5.6.2.2.
• Provide sprinkler protection beneath all obstructions greater than 4 ft. in width.
• Extend sprinkler protection to all combustible concealed spaces.
• Comply with NFPA 13 obstruction tables.
• All valves controlling the water supply for automatic sprinkler systems and
waterflow switches on all sprinkler systems shall be electrically supervised.
• Comply with obstructed/non-obstructed construction rules for sprinkler head
placement.
• Sprinkler heads spaced closer than 6 ft. apart must be baffled.
• Modifications involving 20 or more heads require hydrostatic test and system
isolation if necessary.
• For dry pipe and double interlock preaction systems, in addition to the standard
hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24
hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the
24 hours shall be corrected.
• These conditions apply to all sprinkler piping exposed as necessary to
accomplish the permitted scope of work.
All code references are NFPA 13, 2013 Edition.
56'-0'±
•
1
9'-10'
\♦ 14
8'-5' 1-5•
NEW COOLER
1 •
9'-10'
•
\ 1
7,-10/2'
CU 6,
• \ , ♦ 1� , \ \
7-102' 4-4
2
NEW FREEZER
7'-10O' ` 7,-1O�•
•
13/4 \1Y4
3'-6' — 4'-41C
X
LJ
1
7,-103'
•
CONNECT TO
EXISTING 2)/2" CUTLET
1
+i
0
7'-103/2'
•
EXISTING FULLY
SPRINKLERED
BUILDING
EXISTING 8' RISER.
�!D CHANGES TO
EXISTING RISER
EX. 6
26'-0"±
EXISTING FULLY
SPRINKLERED
BUILDING
EXISTING FULLY
SPRINKLERED
BUILDING
EXISTING FULLY
SPRINKLERED
BUILDING
(1)FIRE SPRINKLER PLAN CI+,
WOOD JOIST OR TRUSS
6' SAMMY
SCREW
6' ALL THREAD ROD
HANGER RING
SPRINKLER PIPE
C?)HANGER DETAIL
NTS
CO\STCT
0
NOT
1. ALL WORK PER NFPA 13 2013
2. EXISTING SYSTEM IS A WET SYSTEM IN A FULLY
PROTECTED, HEATED EXISTING BUILDING.
3. ALL NEW PIPING IS 1" SCH 40
4. NO CHANGES ARE BEING MADE TO EXISTING SPRINKLER
COVERAGE OUTSIDE OF NEW COOLER/FREEZER.
5. EXISTING SYSTEM HAS 160 PSI AVAILABLE AT RISER.
IS:
22L-
ttitla
Olima
Without Comments
As Noted in Red
Per The Attached Letter
I hep plans have been reviewed by The Tukwila Fire
2re'rention Bureau for conformance with current City
nndards. Acceptance Is `subject to errors and
:missions which do not authorize violations of adopted
;':r<dards and ordinances, The responsibility for the
! le luacy of design Bests totally with the designer.
Additions, deletions or revisions to these drawings after
this date will void this acceptance and will require a
resubmittal of revised drawings for subsequent approval.
Final acceptance is subject to field test and inspection by
"The Tukwila Fire Prevention Bureau.
Date: "' - I `f By: �� )
TUKWILA FIRE DEPARTMENT
Plea calf 206-57547 and
give this Fire Permit No.
i:nd exact address for shut-
uown or restoration approval.
e
WASHINGTON TATE
1 CERTIFI���pTE Opp COMPETENCY
i FIRE FROTIGC7ION SPRIN LER SYSTEMS
Michael Todd Maliengren
7223.0107-C Level3 N In
Emerald Fire, L.L.C.
EMERAFL980 R
HANGER NOTES
1. HANGERS SHALL BE SAMMY SCREW ROD AND RING
2. TRAPEZE HANGERS SHALL BE UNISTRUT, UNISTRUT NUT, ROD AND RING.
3. ALL HANGERS PER NFPA 13.
GENERAL NOTES
1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UNDERWRITERS
APPROVED.
2. PIPING DIMENSIONS ARE CENTER TO CENTER.
3. PIPE HANGERS AND METHOD OF HANGING TO BE IN ACCORDANCE
WITH NFPA PAMPHLET #13.
4. EARTHQUAKE BRACING AND JOINING OF PIPE AND FITTINGS SHALL BE IN
ACCORDANCE WITH NFPA PAMPHLET #13.
5. OWNER TO PROVIDE A MINIMUM OF 40. F TO PREVENT WATER IN PIPES
FROM FREEZING IN AREAS PROTECTED BY A WET PIPE SPRINKLER
SYSTEM.
6. STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE SPRINKLER
PIPING IS THE RESPONSIBILITY OF THE OWNER AND OR HIS STRUCTURAL
REPRESENTATIVES.
Sprinklers Used
SUN STAR C I
DLER FREEZER
SYM
SPRINKLER OtIFICE SIZE, TYPE & FINISHQUAN
TEMP
MIR
1089 AND
1 NE PARK E. TUKWILLA, WA
GLOBE GL5635 QR CHQRME DRY PENDENT
14
200•
5.6
EMERALD FIRE JOB NUMBER: 214131
EMERALD FIRE
'
FIRE SPRINKLER SPECIALISTS
11021 CRAMER RD. K.P.N. ���®
GIG HARBOR, WA, 98329
23
8572O5 JUL 2014
EMERAFL980MR TU KWI LA FIRE
TOTAL
14
DATE' 7-22-14
REVI
DRAWN' MH/AD
4/.2s.zrz x2ote.—
SHEET, 1 tIF 1