Loading...
HomeMy WebLinkAboutPP - 1089 ANDOVER PARK EAST - SUN STAR - PERMITS AND PLANS1089 ANDOVER PARK EAST ASSOCIATED PERMITS 14-S-159 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** (� �� King Co. Assessor's Tax No.: Site Address: lO 3 LuF�oy» I`�2 �= ►T� J Suite Number: Floor: Tenant Name: T7a- F a New Tenant? ❑ - Yes ❑ - No Property Owner's Name: Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: w C -1'R l 1-1 1�'rt2� tv\ Company Name: E ke.co Ft t Day Telephone: 2S 3 (o6 ,12_t.'1 Mailing Address: ICUZL C2' . i'ti2 te-V__13 0-3 (1 i.< 14A -21301Z VA-- %iZ5 City State Zip E-mail Address: Vet' IQ-tc t ci 1 tie- Fax Fax Number: Z s e' k S 7- z31Z _ ``-1 Total number of new/relocated devices or sprinkler heads: t ` Valuation of Project (contractor's bid price): $ 2 7 51,1 .du Scope of Work (please provide detailed information): A 'A 44.1 SP2t4-0 ue (N 44,te- co_0(€- - PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revisron by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 4OWN R OR AUTHOJ2IZ A NT:-Z1S/I & ' Signature: Print Name: Jt ? 73-A lit 6l S 1 _ON.1 Day Telephone: Plan Permit App.doc 6/4/14 TFD FP Form 8 Date: % Z 3 4- 2 S3 - S-7 —Za FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Sunstar Foods 1089 Andover Park East Permit No.: 14-S-159 Date: July 29, 2014 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2'/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. 56'-0'± • 1 9'-10' \♦ 14 8'-5' 1-5• NEW COOLER 1 • 9'-10' • \ 1 7,-10/2' CU 6, • \ , ♦ 1� , \ \ 7-102' 4-4 2 NEW FREEZER 7'-10O' ` 7,-1O�• • 13/4 \1Y4 3'-6' — 4'-41C X LJ 1 7,-103' • CONNECT TO EXISTING 2)/2" CUTLET 1 +i 0 7'-103/2' • EXISTING FULLY SPRINKLERED BUILDING EXISTING 8' RISER. �!D CHANGES TO EXISTING RISER EX. 6 26'-0"± EXISTING FULLY SPRINKLERED BUILDING EXISTING FULLY SPRINKLERED BUILDING EXISTING FULLY SPRINKLERED BUILDING (1)FIRE SPRINKLER PLAN CI+, WOOD JOIST OR TRUSS 6' SAMMY SCREW 6' ALL THREAD ROD HANGER RING SPRINKLER PIPE C?)HANGER DETAIL NTS CO\STCT 0 NOT 1. ALL WORK PER NFPA 13 2013 2. EXISTING SYSTEM IS A WET SYSTEM IN A FULLY PROTECTED, HEATED EXISTING BUILDING. 3. ALL NEW PIPING IS 1" SCH 40 4. NO CHANGES ARE BEING MADE TO EXISTING SPRINKLER COVERAGE OUTSIDE OF NEW COOLER/FREEZER. 5. EXISTING SYSTEM HAS 160 PSI AVAILABLE AT RISER. IS: 22L- ttitla Olima Without Comments As Noted in Red Per The Attached Letter I hep plans have been reviewed by The Tukwila Fire 2re'rention Bureau for conformance with current City nndards. Acceptance Is `subject to errors and :missions which do not authorize violations of adopted ;':r<dards and ordinances, The responsibility for the ! le luacy of design Bests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by "The Tukwila Fire Prevention Bureau. Date: "' - I `f By: �� ) TUKWILA FIRE DEPARTMENT Plea calf 206-57547 and give this Fire Permit No. i:nd exact address for shut- uown or restoration approval. e WASHINGTON TATE 1 CERTIFI���pTE Opp COMPETENCY i FIRE FROTIGC7ION SPRIN LER SYSTEMS Michael Todd Maliengren 7223.0107-C Level3 N In Emerald Fire, L.L.C. EMERAFL980 R HANGER NOTES 1. HANGERS SHALL BE SAMMY SCREW ROD AND RING 2. TRAPEZE HANGERS SHALL BE UNISTRUT, UNISTRUT NUT, ROD AND RING. 3. ALL HANGERS PER NFPA 13. GENERAL NOTES 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UNDERWRITERS APPROVED. 2. PIPING DIMENSIONS ARE CENTER TO CENTER. 3. PIPE HANGERS AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA PAMPHLET #13. 4. EARTHQUAKE BRACING AND JOINING OF PIPE AND FITTINGS SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET #13. 5. OWNER TO PROVIDE A MINIMUM OF 40. F TO PREVENT WATER IN PIPES FROM FREEZING IN AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM. 6. STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE SPRINKLER PIPING IS THE RESPONSIBILITY OF THE OWNER AND OR HIS STRUCTURAL REPRESENTATIVES. Sprinklers Used SUN STAR C I DLER FREEZER SYM SPRINKLER OtIFICE SIZE, TYPE & FINISHQUAN TEMP MIR 1089 AND 1 NE PARK E. TUKWILLA, WA GLOBE GL5635 QR CHQRME DRY PENDENT 14 200• 5.6 EMERALD FIRE JOB NUMBER: 214131 EMERALD FIRE ' FIRE SPRINKLER SPECIALISTS 11021 CRAMER RD. K.P.N. ���® GIG HARBOR, WA, 98329 23 8572O5 JUL 2014 EMERAFL980MR TU KWI LA FIRE TOTAL 14 DATE' 7-22-14 REVI DRAWN' MH/AD 4/.2s.zrz x2ote.— SHEET, 1 tIF 1