Loading...
HomeMy WebLinkAboutPP - 1210 ANDOVER PARK EAST - BIG BOX STORAGE / GRAY CAT COLLECTIVE / NEW IMAGE - PERMITS AND PLANS1210 ANDOVER PARK EAST ASSOCIATED PERMITS 13-S-301 11-S-071 10-S-254 SITE LOCATION Site Address: L" CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 ePROTECTION SYSTEMS PERMIT APPLICATION Ap 'ons and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** nate,a;pplication accepted: King Co. Assessor's Tax No.: \ Tenant Name: Suite Number: AJ f4_.. Floor: AVl (4 -- New New Tenant? Yes ❑ - No Property Owner's Name: G C C City Mailing Address: CONTACT PERSON -if there are questions about the submittal. /2 �\ Name: GC, yDay Telephone: L� Company Name: � ki H ( C n— AV F) Mailing Address: � 6� S (l V' 1 kJ A I State Zip 0,6 of--6CPi City State Zip E-mail Address: l4�� Ci A v— �-� (, .�� Fax Number: 2$ 81 t-- r ? ? o Valuation of Project (contractor's bid price): $ `. @ O Scope of Work (please provide detailed information): C O"v\.c cjr ()Li r C 4-0 -eK S » t4 -t-tezn%2 C SSS PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER ORA HORIZEDAMENT: Signature: Print Name: t1 C Day Telephone: Date: a�6 ?O F-6 ce Plan Permit App.doc 5/14/10 "I'FD FP Form 8 �— 773 r -, &= = ✓ ^ s! l O Without Comments O As Noted in Red O Per The Attached Letter These plans have been reviewed by The Tukwila Fre Prevention Bureau far coniormance with current City .;candards. Acceatarice is subject to errors and n, nissions which Co not eurilorize violations of adopted ndards and ordrr-laces. The responsibility for the ..dequacy or desinn rests totally with the designer. dcntions, deletions d+s:ons to there drewings after this dP: e will veld thic :rotz ic-c and will require a resubmitcar of rcvrset c a; tnys for subsea rent approval. ;=final ecccntance is ;I ro{ect ko rield test and inspection by 1 ne 'rukwiia Frye Prevonr..on Bureau. Date: -1}- 3y: NOTICE A completed, signed, Tukwila Fire Departmeteslf Certificate must be' d to the In.spectcfi=p'rior to cornmencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and f rmination of the testino. i U K1 ILAt if i_ �•C.? ar'ti'er 1-e' . Please call 2u6-575-4407 give this Fire Permit No. -F-v3a- n i exact address for shcrt- '� r n ter r stomion F;apronl, FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: New Image 1210 Andover Park East Permit No.: 10-S-254 Date: November 22, 2010 Reviewer: Al Metzler Fire Protection Project Coordinator (206)575-4407 • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods Tess than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1 "-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2' inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 30 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss'of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2010 Edition. FIRE SPRINKLERS INC. 1524 45th St E, SUITE 102 SUMNER,WA 98390 HYDRAULIC CALCULATIONS FOR New Image 1210 Andover Park East Tukwila, WA 98188 - Paint Booth - FILE NUMBER: 2704 - Paint Booth.sdf DATE: March 29, 2011 -DESIGN DATA - OCCUPANCY CLASSIFICATION: Extra Hazard Group 2 DENSITY: .40 gpm/sq. ft. AREA OF APPLICATION: Entire Booth COVERAGE PER SPRINKLER: 91 sq. ft. NUMBER OF SPRINKLERS CALCULATED: 15 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 624.4 gpm TOTAL WATER REQUIRED (including hose): 1124.4 gpm FLOW AND PRESSURE (@ BOR): 624.4gpm @ 117.7 psi SPRINKLER ORIFICE SIZE: K=8.0 SPRINKLER TYPE: Pendent SPRINKLER TEMP: 155° NAME OF CONTRACTOR: FIRE SPRINKLERS INC DESIGN/LAYOUT BY: Seibert AUTHORITY HAVING JURISDICTION: Tukwila Fire Dept CONTRACTOR CERTIFICATION NUMBER: FIRESI*988RJ CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 38011601 ) HRS SYSTEMS, INC. Items listed in bold print are automatically transfered from the calculation report SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 3/30/2011DESIGN\03-CALCULATIONS\01-HYDRAULIC\2704 - PAINT BOOTH.SDF JOB TITLE: Paint Booth WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SRC 150.0 20.0 6685.0 145.2 1124.4 128.7 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 1124.4 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 500.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 624.4 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 20.2 - - - - 29.8 1H 19.8 K= 8.00 27.9 2 20.2 - - - - 29.9 2H 19.8 K= 8.00 28.0 3 20.2 30.3 3H 19.8 K= 8.00 28.4 4 20.2 - - - - 31.0 4H 19.8 K= 8.00 29.0 5 20.2 - - - - 26.9 5H 19.8 K= 8.00 26.3 6 20.2 - - - - 27.0 6H 19.8 K= 8.00 26.3 7 20.2 27.7 7H 19.8 K= 8.00 27.0 8 20.2 - - - - 28.6 8H 19.8 K= 8.00 27.9 9 20.2 - - - - 30.1 9H 19.8 K= 8.00 29.4 10 20.2 - - - - 26.5 10H 19.8 K= 8.00 25.9 11 20.2 - - - - 26.5 11A 29.0 - - - - 20.7 11H 29.0 K= 8.00 20.7 12 20.2 - - - - 26.5 12H 19.8 K= 8.00 25.9 13 20.2 - - - - 27.1 13H 19.8 K= 8.00 26.4 14 20.2 - - - - 28.5 14H 19.8 K= 8.00 27.8 42.3 42.4 42.6 43.1 41.0 41.0 41.6 42.2 43.3 40.7 36.4 40.7 41.1 42.2 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 3/30/2011DESIGN\03-CALCULATIONS\01-HYDRAULIC\2704 - PAINT BOOTH.SDF JOB TITLE: Paint Booth NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 15 20.2 - - - - 30.7 15H 19.8 K= 8.00 29.9 43.7 A 20.2 - - - - 33.8 B 20.2 34.2 C 20.2 36.1 D 20.2 45.9 E 9.0 57.9 G 26.1 85.6 H 26.1 100.5 J 26.1 104.1 K 26.1 105.8 TOR 26.1 107.5 BOR 4.5 117.7 BF1 -3.0 128.0 BF2 -3.0 - - - - 123.0 - - - SRC -3.0 SOURCE 128.7 624.4 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 3/30/2011DESIGN\03-CALCULATIONS\01-HYDRAULIC\2704 - PAINT BOOTH.SDF JOB TITLE: Paint Booth PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -42.3 2.203 PL 7.54 PF 0.1 1 20.2 0.0 29.8 0.0 3.6 120 FTG ---- PE 0.0 2 20.2 0.0 29.9 0.0 0.014 TL 7.54 PV Pipe: 2 -84.6 2.203 PL 7.54 PF 0.4 2 20.2 0.0 29.9 0.0 7.1 120 FTG ---- PE 0.0 3 20.2 0.0 30.3 0.0 0.051 TL 7.54 PV Pipe: 3 -127.3 2.203 PL 6.54 PF 0.7 3 20.2 0.0 30.3 0.0 10.7 120 FTG ---- PE 0.0 4 20.2 0.0 31.0 0.0 0.108 TL 6.54 PV Pipe: 4 -170.4 2.203 PL 1.50 PF 2.8 4 20.2 0.0 31.0 0.0 14.3 120 FTG T PE 0.0 A 20.2 0.0 33.8 0.0 0.185 TL 15.14 PV Pipe: 5 -41.0 2.203 PL 2.00 PF 0.0 5 20.2 0.0 26.9 0.0 3.5 120 FTG ---- PE 0.0 6 20.2 0.0 27.0 0.0 0.013 TL 2.00 PV Pipe: 6 -82.0 2.203 PL 6.88 PF 0.7 6 20.2 0.0 27.0 0.0 6.9 120 FTG 2L PE 0.0 7 20.2 0.0 27.7 0.0 0.048 TL 15.06 PV Pipe: 7 -123.6 2.203 PL 8.71 PF 0.9 7 20.2 0.0 27.7 0.0 10.4 120 FTG ---- PE 0.0 8 20.2 0.0 28.6 0.0 0.102 TL 8.71 PV Pipe: 8 -165.8 2.203 PL 8.71 PF 1.5 8 20.2 0.0 28.6 0.0 14.0 120 FTG ---- PE 0.0 9 20.2 0.0 30.1 0.0 0.176 TL 8.71 PV Pipe: 9 -209.2 2.203 PL 1.58 PF 4.1 9 20.2 0.0 30.1 0.0 17.6 120 FTG T PE 0.0 B 20.2 0.0 34.2 0.0 0.270 TL 15.22 PV Pipe: 10 -40.7 2.203 PL 1.17 PF 0.0 10 20.2 0.0 26.5 0.0 3.4 120 FTG ---- PE 0.0 11 20.2 0.0 26.5 0.0 0.013 TL 1.17 PV Pipe: 11 -77.1 2.203 PL 0.83 PF 0.0 11 20.2 0.0 26.5 0.0 6.5 120 FTG ---- PE 0.0 12 20.2 0.0 26.5 0.0 0.043 TL 0.83 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 3/30/2011DESIGN\03-CALCULATIONS\01-HYDRAULIC\2704 - PAINT BOOTH.SDF JOB TITLE: Paint Booth PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 12 -117.8 2.203 PL 5.54 PF 0.5 12 20.2 0.0 26.5 0.0 9.9 120 FTG ---- PE 0.0 13 20.2 0.0 27.1 0.0 0.093 TL 5.54 PV Pipe: 13 -158.9 2.203 PL 8.71 PF 1.4 13 20.2 0.0 27.1 0.0 13.4 120 FTG ---- PE 0.0 14 20.2 0.0 28.5 0.0 0.162 TL 8.71 PV Pipe: 14 -201.1 2.203 PL 8.71 PF 2.2 14 20.2 0.0 28.5 0.0 16.9 120 FTG ---- PE 0.0 15 20.2 0.0 30.7 0.0 0.251 TL 8.71 PV Pipe: 15 -244.8 2.203 PL 1.58 PF 5.5 15 20.2 0.0 30.7 0.0 20.6 120 FTG T PE 0.0 C 20.2 0.0 36.1 0.0 0.361 TL 15.22 PV Pipe: 16 -170.4 2.703 PL 6.46 PF 0.4 A 20.2 0.0 33.8 0.0 9.5 120 FTG ---- PE 0.0 B 20.2 0.0 34.2 0.0 0.068 TL 6.46 PV Pipe: 17 -379.6 2.703 PL 6.50 PF 2.0 B 20.2 0.0 34.2 0.0 21.2 120 FTG ---- PE 0.0 C 20.2 0.0 36.1 0.0 0.300 TL 6.50 PV Pipe: 18 -624.4 2.703 PL 6.67 PF 9.7 C 20.2 0.0 36.1 0.0 34.9 120 FTG L PE 0.0 D 20.2 0.0 45.9 0.0 0.754 TL 12.89 PV Pipe: 19 -624.4 3.314 PL 11.25 PF 7.2 D 20.2 0.0 45.9 0.0 23.2 120 FTG 2L PE 4.9 E 9.0 0.0 57.9 0.0 0.279 TL 25.81 PV Pipe: 20 -624.4 3.314 PL 59.92 PF 35.0 E 9.0 0.0 57.9 0.0 23.2 120 FTG T4LB PE -7.4 G 26.1 0.0 85.6 0.0 0.279 TL 125.44 PV Pipe: 21 -624.4 3.068 PL 36.67 PF 14.9 G 26.1 0.0 85.6 0.0 27.1 120 FTG ---- PE 0.0 H 26.1 0.0 100.5 0.0 0.407 TL 36.67 PV Pipe: 22 -624.4 4.026 PL 34.00 PF 3.7 H 26.1 0.0 100.5 0.0 15.7 120 FTG ---- PE 0.0 J 26.1 0.0 104.1 0.0 0.108 TL 34.00 PV Pipe: 23 -624.4 5.047 PL 46.75 PF 1.7 J 26.1 0.0 104.1 0.0 10.0 120 FTG ---- PE 0.0 K 26.1 0.0 105.8 0.0 0.036 TL 46.75 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 3/30/2011DESIGN\03-CALCULATIONS\01-HYDRAULIC\2704 - PAINT BOOTH.SDF JOB TITLE: Paint Booth PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 24 -624.4 6.065 PL 102.17 PF 1.7 K 26.1 0.0 105.8 0.0 6.9 120 FTG E PE 0.0 TOR 26.1 0.0 107.5 0.0 0.015 TL 116.17 PV Pipe: 25 -624.4 6.065 PL 21.63 PF 0.8 TOR 26.1 0.0 107.5 0.0 6.9 120 FTG GA PE 9.4 BOR 4.5 0.0 117.7 0.0 0.015 TL 52.63 PV Pipe: 26 -624.4 6.065 PL 112.00 PF 2.0 BOR 4.5 0.0 117.7 0.0 6.9 120 FTG 3L PE 3.2 BF2 -3.0 0.0 123.0 0.0 0.015 TL 139.00 PV Pipe: 27 FIXED PRESSURE LOSS DEVICE BF1 -3.0 0.0 128.0 0.0 5.0 psi, 624.4 gpm BF2 -3.0 0.0 123.0 0.0 Pipe: 28 -624.4 6.280 PL 30.00 PF 0.8 BF1 -3.0 0.0 128.0 0.0 6.5 140 FTG TG PE 0.0 SRC -3.0 SRCE 128.7 (N/A) 0.009 TL 82.00 PV Pipe: 29 42.3 1.380 PL 2.79 PF 2.0 1 20.2 0.0 29.8 0.0 9.1 120 FTG 2ET PE 0.2 1H 19.8 8.0 27.9 42.3 0.137 TL 14.79 PV Pipe: 30 42.4 1.380 PL 2.79 PF 2.0 2 20.2 0.0 29.9 0.0 9.1 120 FTG 2ET PE 0.2 2H 19.8 8.0 28.0 42.4 0.137 TL 14.79 PV Pipe: 31 42.6 1.380 PL 2.79 PF 2.1 3 20.2 0.0 30.3 0.0 9.1 120 FTG 2ET PE 0.2 3H 19.8 8.0 28.4 42.6 0.139 TL 14.79 PV Pipe: 32 43.1 1.380 PL 2.79 PF 2.1 4 20.2 0.0 31.0 0.0 9.2 120 FTG 2ET PE 0.2 4H 19.8 8.0 29.0 43.1 0.142 TL 14.79 PV Pipe: 33 41.0 1.380 PL 0.42 PF 0.8 5 20.2 0.0 26.9 0.0 8.8 120 FTG T PE 0.2 5H 19.8 8.0 26.3 41.0 0.129 TL 6.42 PV Pipe: 34 41.0 1.380 PL 0.42 PF 0.8 6 20.2 0.0 27.0 0.0 8.8 120 FTG T PE 0.2 6H 19.8 8.0 26.3 41.0 0.129 TL 6.42 PV Pipe: 35 41.6 1.380 PL 0.42 PF 0.9 7 20.2 0.0 27.7 0.0 8.9 120 FTG T PE 0.2 7H 19.8 8.0 27.0 41.6 0.132 TL 6.42 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 3/30/2011DESIGN\03-CALCULATIONS\01-HYDRAULIC\2704 - PAINT BOOTH.SDF JOB TITLE: Paint Booth PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 36 42.2 1.380 PL 0.42 PF 0.9 8 20.2 0.0 28.6 0.0 9.1 120 FTG T PE 0.2 8H 19.8 8.0 27.9 42.2 0.136 TL 6.42 PV Pipe: 37 43.3 1.380 PL 0.42 PF 0.9 9 20.2 0.0 30.1 0.0 9.3 120 FTG T PE 0.2 9H 19.8 8.0 29.4 43.3 0.143 TL 6.42 PV Pipe: 38 40.7 1.380 PL 0.42 PF 0.8 10 20.2 0.0 26.5 0.0 8.7 120 FTG T PE 0.2 10H 19.8 8.0 25.9 40.7 0.127 TL 6.42 PV Pipe: 39 36.4 1.380 PL 10.42 PF 2.0 11 20.2 0.0 26.5 0.0 7.8 120 FTG ET PE -3.8 11H 29.0 8.0 20.7 36.4 0.104 TL 19.42 PV Pipe: 40 0.0 1.049 PL 1.00 PF 0.0 11A 29.0 0.0 20.7 0.0 0.0 120 FTG T PE 0.0 11H 29.0 8.0 20.7 36.4 0.000 TL 6.00 PV Pipe: 41 40.7 1.380 PL 0.42 PF 0.8 12 20.2 0.0 26.5 0.0 8.7 120 FTG T PE 0.2 12H 19.8 8.0 25.9 40.7 0.127 TL 6.42 PV Pipe: 42 41.1 1.380 PL 0.42 PF 0.8 13 20.2 0.0 27.1 0.0 8.8 120 FTG T PE 0.2 13H 19.8 8.0 26.4 41.1 0.130 TL 6.42 PV Pipe: 43 42.2 1.380 PL 0.42 PF 0.9 14 20.2 0.0 28.5 0.0 9.0 120 FTG T PE 0.2 14H 19.8 8.0 27.8 42.2 0.136 TL 6.42 PV Pipe: 44 43.7 1.380 PL 0.42 PF 0.9 15 20.2 0.0 30.7 0.0 9.4 120 FTG T PE 0.2 15H 19.8 8.0 29.9 43.7 0.146 TL 6.42 PV NOTES (HASS): (1) Calculations were performed by the HASS 8.1 computer program under license no. 38011601 granted by HRS Systems, Inc. 208 South Public Square Petersburg, TN 37144 (931) 659-9760 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 8 DATE: 3/30/2011DESIGN\03-CALCULATIONS\01-HYDRAULIC\2704 - PAINT BOOTH.SDF JOB TITLE: Paint Booth (2) The system has been calculated to provide an average imbalance at each node of 0.002 gpm and a maximum imbalance at any node of 0.107 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 34.9 ft/sec at pipe 18. (4) PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVly BfyVly GatVly AlmChk DPV1v NPTee 2.203 6.82 13.64 4.09 15.00 8.18 1.36 13.64 13.64 13.64 2.703 9.33 18.65 6.22 21.76 10.88 1.55 15.54 15.54 18.65 3.314 10.19 21.84 7.28 23.29 14.56 1.46 18.93 18.93 21.84 PAGE: A MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVly BfyVly GatVly AlmChk DPV1v NPTee 1.049 2.00 5.00 2.00 5.00 6.00 1.00 10.00 10.00 5.00 1.380 3.00 6.00 2.00 7.00 6.00 1.00 10.00 10.00 6.00 3.068 7.00 15.00 5.00 16.00 10.00 1.00 13.00 13.00 15.00 4.026 10.00 20.00 6.00 22.00 12.00 2.00 20.00 20.00 20.00 5.047 12.00 25.00 8.00 27.00 9.00 2.00 21.00 21.00 25.00 6.065 14.00 30.00 9.00 32.00 10.00 3.00 28.00 28.00 30.00 PAGE: D MATERIAL: DIRON HWC: 140 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G N Ell Tee LngEll ChkVly BfyVly GatVly NPTee 6.280 22.00 47.00 14.00 51.00 16.00 5.00 47.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 9 DATE: 3/30/2011DESIGN\03-CALCULATIONS\01-HYDRAULIC\2704 - PAINT BOOTH.SDF JOB TITLE: Paint Booth WATER SUPPLY ANALYSIS 6685.0 gpm E E a O. w w o rn c a• a 0 a) • • O O N c w v (N S4 N > m , - H C w 1-1v Q E u M) a) e.) w Sa cIral rl iL -H o z aw ro rn ).-11r) m -1 Wr r -H N (! -, O >. Gu 1 • 0 • cn CO wro N C)•m rl a a w N F=C a. 0 g 0 Static: 150.00 psi r N O O 0 O O O O O o O O O O O O O l0 a' N O co ko a' N 'I 0 FC 0 w p r=441 -- a, a --1 -- W 0 0 0 0 0 r-- 0 0 0 M O 0 tf) 0 O M 0 0 CO N 0 O N FLOW (GPM) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 10 DATE: 3/30/2011DESIGN\03-CALCULATIONS\01-HYDRAULIC\2704 - PAINT BOOTH.SDF JOB TITLE: Paint Booth WATER SUPPLY CURVE 156+ I *\ I 0 143+ \ I \ I \ I \\ 130+ X \ I \ I \ I \ 117+ \ I \\ I \ I \ P104+ \ R I \ E I \ S 1 \\ S 91+ \ U 1 R 1 E 1 \ \ \ 78+ \\ ( I \ P 1 \ S 1 \ I 65+ \ 1 \ I \\ I \ 52+ \ I \ I \ I \ 39+ \\ 1 \ 1 \ 1 \ 26+ LEGEND ii\ 1 11 \ 1 X = Required Water Supply.0 psi @ 6685 gpm-> * I 128.75 psi @ 1124.4 gpmow Test Point 13+ I 0++-+---+----+ + + + + + + 0 = Available Water Supply 145.19 psi @ 1124.4 gpmII II 11 Ace Fire System LLC P.O Box 2065 Buckley WA 98321 December 12,2013 Tukwila Fire Attn: Al Metzler Subject: New Image 1210 Andover Park East Disconect paint booth sprinklers. Dear Al: The owner has asked us to obtain permission to remove paint booth sprinklers so the booth can be removed from building. Aprox. 16 heads. Please let us know if this is acceptable. Sincerely, Brad Weber Ace Fire System LLc 206-349-1175 TUKWILA FiRE DEPARTMENT Please ca 5 206-575-4407 and give this Fire Permit Nov and exact address for shut- iown or restoration approval. 11A" DROP ROOF DECK 2" BRANCHLINE Fp 1 SECTION,1 FILTER EXHAUST DUCT E_ DRY SIDEWALL 2" BRANCHLINE 1'/" DROP PENDENT SPRINKLER J i 1 518" STRUT '\ i /' / i �,;' � /7 ,'\ / \/: `�i `•� \% \/ \/ i"\ i'\ \ /,i `\.\/ \ \/. /\ FPy SCALE: 1/2" = 1'-0" 0 2 0-10 2 2 0=4 n 2-0 n j 0-10 0-4 2 5-6% 2 8-8 PAINT BOOTH LL LL `.P D OP \t O� i THIS AREA HAS BEEN HYDRAULICALLY CALCULATED TO DELIVER A EXTRA HAZARD GROUP 2 DENSITY OF: 0.40 OVER THE ENTIRE PAINT BOOTH. 2 4-8Y2 FSI FILE: 2704 - PAINT BOOTH.SDF 2 2 8-8'/z 11/4 06 2 4-5 7-6Y2 CoQ O 2 /5 7-6'/s O 2 2 0-10'/z 7-10 2 0-11'%\ 2 A 5-7 1 /�O 2 CV O 1-6 1 CV 2 1-7 (0 3-11 * 16-3' NORTH FIRE SPRINKLER PIPING PLAN - PAINT BOOTH 2'-111' 2Y/2 MAIN F 3" x 2%' GROOVED REDUCING COUPLING "GROOVED BUTTERF I/419e 4' 5-t eier4-r,0,01 j S FrK alta+- pter:4 r tv; E PAINT BOOTH PAINT BOOTH CONTROL VALVE DETAIL 1:)11y SCALE: 1/2" =1'-0" 131101 /J FF 3 22'-94" 20-9 / 22'-1'/z' FF 3 1-0 o LIJ CUTIN NEW 3" GROOVED TEE 1 5/8" STRUT PS1100 CLAMP 2" TUBE STEEL FRAME UNISTRUT HANGER TYPE W NTS GLU-LAM OR BEAM �- MODEL #GST 20 111111 ALL THREAD ROD HANGER RING SAMMY SUPERSCREW HANGER TYPE S NTS /////////// TOLCO FIG. 909 (2) TOLCO FIG. 1000 "FAST CLAMP" (2) RISER BRACE NTS MODEL #GST 20 \-2'/" X 8'-0" LONG SCH 10 PIPE TRAPEZE W/ 3/8" ROD WELDED @ EA END ALL THREAD ROD HANGER RING TRAPEZE HANGER TYPE T NTS POST BASE POWERSTRUT 809 NUT & WASHER —KWIK BOLT 1/2" X 0'-3" - CONCRETE WALL BALL THREAD ROD UNISTRUT POST HANGER RING HANGER TYPE U NTS FIG. 909 SWIVEL SWAY BRACE FITTING —FIG. 1000 FAST CLAMP" SWAY BRACE ATTACHMENT BRACE PIPE LATERAL BRACE NTS SCOPE OF WORK: 1. INSTALL NEW CONTROL VALVE AND REQUIRED PIPING AND SPRINKLERS FOR NEW PAINT BOOTH.. 2. DESIGN AND SPRINKLER SPACING TO BE PER NFPA #13 (EXTRA HAZARD GROUP 2). 3. PLAN SUBMITTAL TO AND APPROVAL BY THE CITY OF TUKWILA. 4. MATERIALS PER NFPA #13 STANDARDS AS SELECTED BY FSI. 5. TESTING PER NFPA #13 AND THE CITY OF TUKWILA. GENERAL NOTES: 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL AND/OR FM APPROVED. 2. PIPING DIMENSIONS ARE CENTER TO CENTER EXCEPT RISER DIMENSIONS AND MAINS, SHOWN THUSLY (1-6), WHICH ARE END TO END. 3. EARTHQUAKE BRACING SHALL BE PROVIDED IN ACCORDANCE WITH NFPA PAMPHLET #13. 4. PIPE HANGER AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA PAMPHLET #13. 5. PIPING SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET #13. 6. JOINING OF PIPE AND FITTINGS, THREADED AND WELDED, SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET #13. 7. OWNER TO PROVIDE ADEQUATE HEAT TO PREVENT WATER IN PIPES FROM FREEZING IN AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM. 8, STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE SPRINKLER PIPING IS THE RESPONSIBILITY OF THE OWNER AND/OR HIS STRUCTURAL REPRESENTATIVE. 9. ALL FIRE ALARMS, WIRING AND MONITORING ARE TO BE INSTALLED BY OTHERS. CONSTRUCTION NOTES: 1. ALL NEW THREADED PIPE TO BE BLACK, IMPORT SCHEDULE 40 WITH BLACK, DUCTILE IRON THREADED FITTINGS. 2. ALL NEW GROOVED PIPE TO BE BLACK, DYNAFLOW JOINED WITH GROOVED FITTINGS AND COUPLINGS. 3. THE PAINT BOOTH TO BE DEIGNED AND HYDRAULICALLY CALCULATED PER NFPA #13, EXTRA HAZARD GROUP 2 TO A DENSITY OF .40 / THE ENTIRE BOOTH. 4. TYPICAL: HANGER TO BE HANGER TYPE W, UNISTRUT (UNLESS NOTED OTHERWISE). Without Comments ,J" As Noted in Red 0 Per The Attached Letter These plans have been reviewed by The Tukwila Fire 'prevention Bureau for conformance with current City 7tor,dards. Acceptance is subject. to errors and omissions which do not authorize violations of adopted '>tandards and ordinances. The responsIbility for the adequacy of design rests totally wlth the designer. Additions, deletions or revisions to these drawings after this date will void this f�ccep'ta!ice and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. By: Al/v1 fl1 sa FIG. 909 NO -THREAD SWIVEL SWAY BRACE ATTACHMENT FIG. 4A PIPE CLAMP FOR SWAY BRACE BRACE PIPE LONGITUDINAL BRACE NTS DRAWING SYMBOLS REVISIONS HYDRAULIC DESIGN INFO. HANGER LEGEND SPRINKLER HEAD LEGEND • -ALARM VALVE RISER A- FLOW SWTICH RISER - DRY PIPE RISER - DELUGE/P.A. RISER O - FIRE DEPARTMENT CONNECTION /(f. - WATER MOTOR GONG - ELECTRIC BELL -FLEXIBLE GROOVED COUPLING —Q— - RIGID GROOVED COUPLING -0- - THREADED PIPE COUPLING - CONTROL VALVE - CHECK VALVE - PIPE HANGER (SEE CHART) - SEISMIC BRACE (SEE CHART) 1 9-0 1 (8-10) - WELDED PIPE TAG - BRANCHLINE NUMBER PIPE SIZE & LENGTH - PIPE SIZE & LENGTH (CUT) - HYDRAULIC NODE * 10'-10" FF Q - ELEVATION DATUM * 0'-10" TS Q. - CENTERLINE OF PIPE TO DECK MK DATE BY DESCRIPTION 71 THIS SYSTEM IS HYDRAULICALLY DESIGNED ❑THIS SYSTEM IS NOT HYDRAULICALLY DESIGNED A U -HOOK L "L" ROD SPRINKLER TYPE / SIN NUMBER MFG MODEL SYMBOL K -FAC THREAD TEMP FINISH CANOPY QTY - FLOW TEST - STATIC: 150 PSI RESIDUAL: 20 PSI GPM FLOWING: 6685 PGM DATE & TIME: - SYSTEM DESIGN - REMOTE AREA: ENTIRE BOOTH DENSITY: .40 MAX AREA/HEAD 91 SQ. FT. B C COACH SCREW ROD N "C" CLAMP P TOGGLE NUT HDI -P PENDENT/TY4251 TYCO TY -B • 8.0 3/4" 155° DRY HORIZONTAL SIDEWALL / VK252 VIKING VK252 8.0 3/4" 286° BRASS BRASS 14 1 D TOP BEAM CLAMP W/ STRAP R WEDGE ANCHOR E EYE ROD S SAMMY SUPER SCREW (GST20) F FLUSH SHELL SW SAMMY SIDEWINDER (SWG20) G CEILING FLANGE SX SAMMY X -PRESS H SIDE BEAM BRACKET T TRAPEZE J "J" BOLT U UNISTRUT POST K -FACTOR 8.0 K SHORT CLIP W STRUT TOTAL THIS SHEET 15 Fire Sprinklers WA CL# FIRESI*988RJ 1524 45th St E - Suite 102 Sumner, WA 98390 (253) 826-0099 PROJECT: New Image - Paint Booth 1210 Andover Park East Tukwila, WA 98188 I UPSWILA FIRE DEPA1-:44t11 , P e se call: 575.4407 and give this job No• l/"S"'07/ ani xact address for shut. • .-.r(', or rostoration Floore001 PAID MAR 31 2011 TUKWILA FIRE , y dff CONTRACT WITH: New Image 1210 Andover Park East Tukwila, WA 98188 Greg Rust DESIGNER: Seibert DATE: March 29, 2011 SCALE: As Noted HAZARD: As Noted AHJ: • City of Tukwila JOB # 2704 SHEET# FP1 OF 1 COACHSCREW RO SPLIT RING HANGER SPLIT RING HANGER HANGER TYPE W NTS CC ,;,, O Without Comments CI As Noted in Red 12f Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for +-onformanc. _.wIt;h current City. standards. Acceptzw, u: sub;ir cl :f. , c l ter.: and omissions which do , :/: . ;1oriz.: ‘nolailOOF of adopted standards and c? <., ;;::,, TI1C' II>r)c,ir.,-hiiicy for the adequacy of deslo :r ! ;�}.,� ,.,. .#,esigner. Additions, delet o; �:. +. c rawings atter this date will void t quire a resubmittal of revisec::; : ^.'•` Ii; f: 1. erlt. a=pproval. Final acceptance is suOlect to freica inspection by The Tukwila Fire Prevention Bureau. Date: / 1-€)-1-j O By: i MODEL #GST 20 ALL THREAD ROD HANGER RING SAMMY SUPERSCREW HANGER TYPE S20 NTS I t l it i LA FIRE DEPARTMIt Please call: 575-4407 and give this job No.10 - - )%s-1-1 ,.a :xact adc_lress for shut, ,+,in ur r.9sturation aooroval, EMI{': TEAT Weld stamps must be inspected before pipe is hung. Do not paint piping prior to hydrosta- €c test approval. D \ 1 QA-\ 114 pQr1114 10-0 5 81/2 ----- 0-101/2 1-0 kll 1Y4 5� 11/4 7-0 2-7 ° ti .- (E)1% (E)1 EXISTING NIC (E)1 FIRE SPRINKLER PIPING TI PLAN SCALE: 1/8" = SCOPE OF WORK: 1. ADD AND RELOCATE SPRINKLERS AS NECESSARY FOR THE NEW WALLS AND CEILINGS. 2. SYSTEM TO BE DESIGNED IN ACCORDANCE WITH NFPA #13. 3. PLAN SUBMITTAL TO AND APPROVAL BY CITY OF TUKWILA. 4. MATERIALS PER NFPA #13 STANDARDS AS SELECTED BY FSI. 5. TESTING PER NFPA #13 AND THE CITY OF TUKWILA. GENERAL NOTES: 1. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL LISTED OR FM APPROVED. 2. PIPING DIMENSIONS ARE CENTER TO CENTER EXCEPT RISER & DIMENSIONS SHOWN THUSLY (1-6), WHICH IS END TO END. 3. EARTHQUAKE BRACING SHALL BE PROVIDED IN ACCORDANCE WITH NFPA PAMPHLET #13. 4. PIPE HANGERS AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA PAMPHLET #13. 5. PIPING SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET #13. 6. JOINING OF PIPE AND FITTINGS, THREADED AND WELDED SHALL BE IN ACCORDANCE WITH NFPA PAMPHLET #13. 7. OWNER TO PROVIDE ADEQUATE HEAT TO PREVENT WATER IN PIPES FROM FREEZING IN AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM. 8. STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE SPRINKLER PIPING IS THE RESPONSIBILITY OF THE OWNER AND/OR HIS STRUCTURAL. 9. ALL FIRE ALARMS, WIRING AND MONITORING ARE TO BE INSTALLED BY OTHERS. RESPONSIBILITY OF THE OWNER AND/OR HIS STRUCTURAL. CONSTRUCTION NOTES: 1. ALL WET SYSTEM PIPING TO BE SCHD 40. 2. ALL NEW FITTINGS TO BE THREADED DUCTILE IRON. 3. ARMOVERS LONGER THAN 1'-0" SHALL HAVE A HANGER . 4. TYPICAL HANGER TO BE A SPLIT RING (U.N.0). VICINITY MAP SCALE: NTS DRAWING SYMBOLS HYDRAULIC DESIGN INFO. HANGER LEGEND HEAD LEGEND - ALARM VALVE RISER - FLOW SWTICH RISER - DRY PIPE RISER - DELUGE/P.A. RISER 0 °V' - FIRE DEPARTMENT CONNECTION - WATER MOTOR GONG n - ELECTRIC BELL F FLEXIBLE GROOVED COUPLING - RIGID GROOVED COUPLING - THREADED PIPE COUPLING --[>t<1- - CONTROL VALVE �- - CHECK VALVE PIPE HANGER (SEE CHART) - PIPE HANGER (SEE CHART) ( A-1 ) - WELDED PIPE TAG O- BRANCHLINE NUMBER 1 9-0 PIPE SIZE & LENGTH •1 (8-10) PIPE SIZE & LENGTH(CUT) - HYDRAULIC NODE 10'-0" AFF ELEVATION DATUM 0'-10" BOD - CENTERLINE OF PIPE TO DECK ❑THIS SYSTEM IS THIS SYSTEM IS NOT HYDRAULICALLY DESIGNED I I HYDRAULICALLY DESIGNED A U -HOOK L "L" ROD SPRINKLER TYPE MFG MODEL SYMBOL ORIFICE FINISH CANOPY TEMP K -FAC QTY FLOW TEST STATIC xx RESIDUAL xx GPM FLOWING xx DATE & TIME xx B COACH SCREW ROD N TOGGLE NUT UPRIGHT VIKING VK300 0 1/2" C "C" CLAMP P HDI -P RECESSED PENDENT VIKING VK302 • 1/2" BRASS CHROME 155° 5.6 4 CHROME 155° 5.6 3 D TOP BEAM CLAMP W/ STRAP R WEDGE ANCHOR HORIZONTAL SIDEWALL RELIABLE VK304 1/2" CHROME CHROME 155° 5.6 6 E EYE ROD S SAMMY SIDEWINDER (SWG20) SYSTEM DESIGN F FLUSH SHELL S20 SAMMY SUPER SCREW (GST20) REMOTE AREA xx DENSITY xx MAX. AREA/HEAD xx K -FACTOR xx xx G CEILING FLANGE SX SAMMY X -PRESS H SIDE BEAM BRACKET T TRAPEZE J "J" BOLT U UNISTRUT POST K SHORT CLIP w SPLIT RING TOTAL THIS SHEET 13 Fire Sprinklers WA CL# FIRESI*988RJ 1524 45th St E - Suite 102 Sumner, WA 98390 (253) 826-0099 PROJECT: New Image 1210 Andover Park East Tukwila, WA 98188 CONTRACT WITH: New Image 1210 Andover Park East Tukwila, WA 98188 PAID NOV 22 2010 TUKWILA FIRE cc '( f51) DESIGNER: Seibert DATE: November 19, 2010 SCALE: As Noted HAZARD: As Noted AHJ: City of Tukwila JOB # XXXX SHEET # FP1 OF 1