Loading...
HomeMy WebLinkAboutPP - 4522 S 133RD ST - FARWEST PAINT MFG. COMPANY - PERMITS AND PLANS4522 S 133RD ST ASSOCIATED PERMITS 19-F-053 CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** 44/4., "'"v SITE LOCATION King Co. Assessor's Tax No.: L.� 2 ? r(. (i �tk��ti W�- 7�J6d Site Address: I �� I J J Suite Number: Floor: Property Owner's Name: GL:1 W e" Pct Mailing Address: `7 J �12 S � 3 ? f . —10 k t :1 Tenant Name: City CONTACT PERSON-if��� k'Mfr1S3f theere are questions about the submittal. Name: i-1 O nDay Telephone: f� / e!y 3 l (� Company Name: 5-ii-4-f.� 5 MailingAddress: I ) C1W'�al- P-/`f� - c� VY %Rot J City E-mail Address: Ahtl , �-e J e �'�dI r 1t.L, (...4,-,4, Fax Number: jJ -n�Zip Go lIp v \,1 Contractor's City of Tukwila NICET III number: Business License number: New Tenant? ❑ - Yes No L%! 9k/ ° State Zip Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ 66 . ,� Scope of Work (please provide detailed information) k;e- J'6S iZ r l @y.��r� s�/�✓ NIA -r114,1, e-650( a-h6kx syiu f7&r,) tgLv‘-. p r1 1-04-1-- lf% 1 F 30 IAidL.,4-ie-. PERMIT APPLICATION NOTES Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. PAID ,.3 BUILDING OWNE ' :'i ' AUTHO ' D 4AGENT: MAR 23 20195W7 0 Signature: TUKWILI 1 F Date: �E /� Date: Gln Print Name: `_� a �'(� 16,44" Day'elepTione: t13-5 "l -(/ ,3 7 7 vl Plan Permit App.doc 8/22/14 TFD FP Form 8 ES -50X Intelligent Addressable FACP with Communicator DF -60953:C FlYeLITeAL71'1'Y1.S by Honeywell Addressable Fire Alarm Control Panels General The ES -50X is the latest intelligent addressable fire alarm control panel (FACP) from Fire•Lite Alarms and is a direct replacement for the MS-9050UD/LS. The ES -50X comes with a pre-installed communi-cator and supports up to 50 addressable devices in any combination of detectors or modules. With an extensive list of powerful features, the ES -50X programs just like Fire•Lite's other addressable panels, yet fits into applications previously served only by conventional panels. The pre-installed IPOTS-COM is a dual technology (POTS and IP) communicator. The POTS transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The IP communicator's internet monitoring capability sends alarm signals over the Internet saving the monthly cost of two dedi- cated business telephone lines. Although not required, the second- ary telephone line may be retained providing backup communication over the public switched telephone line. Optional cellular reporting is available using the CELL -MOD or CELL -CAB -FL. Remote and local programming of the control panel is possible using the FS -Tools Upload/Download utility. Programming databases can be uploaded/downloaded via the panel's USB port (and USB cable) or via an ethernet connection using the IPOTS-COM communicator. The USB port also allows for the download or upload of the entire program, history file, walk -test data, current status and system volt- ages by means of a USB flash drive. The power supply and all electronics are contained on a circuit board supported on a new quick install chassis and housed in a metal cabinet. Available accessories include local and remote upload/download software, remote annunciators, and reverse polar- ity/city box transmitter (4XTMF). Features • Listed to UL Standard 864, 10th edition • Pre-installed IPOTS-COM Ethernet IP and POTS (Plain Old Tele- phone Service) Central Station Communicator • Optional CELL -MOD or CELL -CAB -FL GSM Central Station Communicator over AlarmNet® • Compatible with SWIFT® wireless devices • Auto -programming (learn mode) reduces installation time. Reports two devices set to the same address • Two independently programmable, built-in Style Z (Class A) or Style Y (Class B) NAC circuits • Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices • Notification Appliance Circuit End of Line resistor matching • Four programmable function keys for ease of maintenance • Two programmable relays and one fixed trouble relay • Built-in Programmer • Integral 80 -character LCD display with backlighting • Real-time clock/calendar with automatic daylight savings control • History file with 1,000 event capacity • Addressable sounder base • Multi -criteria detector (smoke, heat, CO) with programmable response • Control module delay timer • Automatic detector sensitivity testing (NFPA 72 compliant) • Automatic device type -code verification • Point trouble identification • Waterflow selection per module point • Alarm verification selection per detector point • Maintenance alert warns when smoke detector dust accumula- tion is excessive • One-person audible or silent walktest with walktest log & printout • System alarm verification selection per detector point • PAS (Positive Alarm Sequence) and Pre -signal per point (NFPA 72 compliant) • Up to 16 ANN -BUS annunciators- 8 per each ANN -Bus • Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote annunciator • Upload/Download of program and data via USB with optional FS - Tools Programming Utility SLC COMMUNICATION LOOP • Supports LiteSpeed TM and CLIP protocols • SLC operates up to 10,000 ft. (3,000 m) in LiteSpeed mode with twisted, unshielded wire • Single addressable SLC loop which meets NFPA Class B and Class A requirements • 50 addressable device capacity (any combination of addressable detectors and modules) • Compatible with Fire•Lite's addressable devices (refer to the SLC Wiring Manual) NOTIFICATION APPLIANCE CIRCUITS (NACS) • Two independently programmable output circuits. Circuits can be configured for the following outputs: — Style Y (Class B) — Style Z (Class A) • Silence Inhibit and Autosilence timer options • Continuous, March Time, Temporal, or California code for main circuit board NACs with two-stage capability • Selectable strobe synchronization per NAC • 2.5 A special application, 250mA regulated, total power for NACs NOTE: Maximum or total 24VDC system power shared between all NAC circuits and the ANN -BUS is 2.7 A PROGRAMMING AND SOFTWARE • Autoprogramming (learn mode) reduces installation time OF -60953:0 • 7/16/2018 — Page 1 of 4 • Custom English labels (per point) may be manually entered or selected from an internal library file • Two programmable Form -C relay outputs • 50 software zones • Continuous fire protection during online programming • Program Check automatically catches common errors not linked to any zone or input point • OFFLINE PROGRAMMING: Create the entire program in your office using FS -Tools, a Windows® -based software package, and upload/download system programming locally. Offline program- ming requires an ethernet connection. FS -Tools is available on www.firelite.com. User interface LED INDICATORS • Fire Alarm (red) • CO Alarm (red) • AC Power (green) • Supervisory (yellow) • Trouble (yellow) • Ground fault (yellow) • Battery fault (yellow) • Disabled (yellow) • Maintenance (yellow) • Communication (yellow) • Alarm Silenced (yellow) • F1 -F4 Programmable Function Keys (yellow) KEYPAD • 16 key alpha -numeric pad • Acknowledge • Alarm Silence • Drill (Manual Evacuate) • Four (4) programmable function keys • Reset (lamp test) Product Line Information ES -50X: Addressable Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display, pre-installed IPOTS-COM communicator, chassis with transformer, backbox with door, plastic bag containing screws, cables, key, etc. (For ES-50XC, refer to DF - 60954.) FS -Tools: Programming software for Windows® -based PC com- puter. Available for download at www.firelite.com. CELL-CAB-FL/CELL-MOD: Optional GSM communicators. IPOTS-COM: Dual technology (POTS and IP) communicator. (replacement board) DP -ES -R: Optional dress panel for the ES -50X. TR -CE: Optional trim ring for semi -flush mounting. BB -2F: Optional cabinet for one or two modules. BB -6F: Optional cabinet for up to six modules mounted on CHS -6 chassis. BB -26: Battery backbox, holds up to two 25 AH batteries & CHG-75. BB -55F: Battery box, houses two 55 AH batteries CHS -6: Chassis, mounts up to six multi -modules in a BB -6F cabinet. CHG-75: Battery charger for lead -acid batteries with a rating of 25 to 75 AH. CHG-120F: Remote battery charging system for lead -acid batteries with a rating of 55 to 120 AH. Requires additional BB -55F for mount- ing. BAT Series: Batteries, see data sheet DF -52397. PRN Series: UL listed compatible event printer. Uses tractor -fed paper. OPTIONAL MODULES 4XTMF Reverse Polarity Transmitter Module: Provides a super- vised output for local energy municipal box transmitter, alarm and trouble. Includes a disable switch and disable trouble LED. COMPATIBLE ANNUNCIATORS ANN -80: Remote, red LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- shielded. ANN -100: Remote LCD annunciator mimics the information dis- played on the FACP LCD display. Recommended wire type is un- shielded. For use in FM applications only. ANN -I/O: LED Driver Module provides connections to a user sup- plied graphic annunciator. (See DF -52430.) ANN -LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble, and Supervisory. Ships with red enclosure. (See DF - 60241.) ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DF -60241.) ANN-RLY: Relay Module provides 10 programmable Form -C relays. Can be mounted inside the cabinet. (See DF -52431.) ANN-S/PG: Serial/Parallel Printer Gateway module provides a con- nection for a serial or parallel printer. (See DF -52429.) ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. SD365: Addressable low -profile photoelectric smoke detector. Lite - Speed only. SD365-IV: Addressable low -profile photoelectric smoke detector. Ivory. LiteSpeed and CLIP mode. SD365T: Addressable low -profile photoelectric smoke detector with thermal sensor. LiteSpeed only. SD365T-IV: Addressable low -profile photoelectric smoke detector with thermal sensor. Ivory. LiteSpeed and CLIP mode. SD365R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. LiteSpeed only. SD365R-IV: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. Ivory. Lite - Speed and CLIP mode. H365: Low -profile 135°F fixed thermal sensor. LiteSpeed only. H365 -IV: Low -profile 135°F fixed thermal sensor. Ivory. LiteSpeed and CLIP mode. H365R: Low -profile, intelligent, rate -of -rise thermal sensor. Lite - Speed only. H365R-IV: Low -profile, intelligent, rate -of -rise thermal sensor. Ivory. LiteSpeed and CLIP mode. H365HT: Low -profile intelligent 190°F/88°C fixed thermal sensor. LiteSpeed only. H365HT-IV: Low -profile intelligent 190°F/88°C fixed thermal sensor. Ivory. LiteSpeed and CLIP mode. Legacy Devices SD355: Addressable low -profile photoelectric smoke detector. SD355T: Addressable low -profile photoelectric smoke detector with thermal sensor. SD355R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. SD355CO: Addressable, low -profile device that provides fire, heat, and carbon monoxide (CO) detection. H355: Fast -response, low -profile heat detector. H355R: Fast -response, low -profile heat detector with rate -of -rise option. H355HT: Fast -response, low -profile heat detector that activates at 190°F/88°C. Page 2 of 4 — DF -60953:C • 7/16/2018 AD355: Low -profile, intelligent, "Adapt" multi -sensor detector (B350LP base included). B200S: Programmable, addressable sounder base B200SR: Addressable sounder base. BEAM355: Intelligent beam smoke detector. BEAM355S: Intelligent beam smoke detector with integral sensitiv- ity test. D355PL: InnovairFlex low -flow non -relay duct -detector housing; includes SD355R. DNR: InnovairFlex low -flow non -relay duct -detector housing. (Order SD355R/SD365R separately.) DNRW: InnovairFlex low -flow non -relay duct -detector housing, with NEMA -4 rating. Watertight. (Order SD355R/SD365R separately.) Addressable Modules MMF-300: Addressable Monitor Module for one zone of normally - open dry -contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end -of -line resistor. Mod- ule may be configured for either a Style B (Class B) or Style D (Class A) IDC. MDF -300: Dual Monitor Module. Same as MMF-300 except it pro- vides two Style B (Class B) only IDCs. MMF-301: Miniature version of MMF-300. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. MMF-302: Similar to MMF-300. Addressable Monitor Module for one zone of conventional two -wire detectors. Requires resettable 24 VDC power. Refer to the Device Compatibility Document for listed compatible devices and quantity limitation. CMF -300: Addressable Control Module for one Style Y/Z (Class B/ A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. NAC option requires external 24 VDC to power notification appliances. CRF -300: Addressable relay module containing two isolated sets of Form -C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. BG-12LX: Addressable manual pull station with interface module mounted inside. 1300: This module isolates the SLC loop from short circuit conditions (required for Style 6 or 7 operation). 150-6: Six -fault isolator module. Mount one or two modules in a BB -2F cabinet (optional). Mount up to six modules on a CHS -6 chassis in a BB -6F cabinet. SMB500: Used to mount all modules except MMF-301 and M301. MMF-300-10: Ten -input monitor module. Mount one or two modules in a BB -2F cabinet (optional). Mount up to six modules on a CHS -6 chassis in a BB -6F cabinet. MMF-302-6: Six -zone interface module. Mount one or two modules in a BB -2F cabinet (optional). Mount up to six modules on a CHS -6 chassis in a BB -6F cabinet. CMF -300-6: Six -circuit supervised control module. Mount one or two modules in a BB -2F cabinet (optional). Mount up to six modules on a CHS -6 chassis in a BB -6F cabinet. CRF -300-6: Six -relay control module (Form -C relays). Mount one or two modules in a BB -2F cabinet (optional). Mount up to six modules on a CHS -6 chassis in a BB -6F cabinet. SWIFT Wireless Devices W -GATE: LiteSpeed Wireless Gateway W-SD355: LiteSpeed intelligent, wireless photo detector. W-H355R: LiteSpeed intelligent wireless rate of rise (135°) heat detector. W-SD355T: intelligent wireless photo/heat detector. W -H355: LiteSpeed intelligent wireless fixed -temperature (135°) heat detector. W-MMF: LiteSpeed Intelligent wireless monitor module. W -CRF: LiteSpeed Intelligent wireless relay module. W-BG12LX: LiteSpeed Intelligent wireless pull station. WAV -RL, WAV-WL,WAV-CRL,WAV-CWL: LiteSpeed Intelligent AV bases. W -USB: Wireless USB radio/antenna dongle that plugs into the USB port of a PC running SWIFT Tools. SWIFT Tools: Programming and diagnostic utility for the Wireless Gateway and devices. Available for download from firelite.com. NOTE: For more information on Compatible Addressable Devices for use with the ES -50X, see the following data sheets (document num- bers): SD365 Series (DF -61010), H365 Series (DF -61011), AD355 (DF -52386), BG-12LX (DF -52013), CMF -300-6 (DF -52365), CRF -300-6 (DF -52374), CMF/CRF Series (DF -52130), CP355 (DF -52383), H355 Series (DF -52385), 1300 (DF -52389), ISO -6 (DF -60485), MMF-300 Series/MDF-300 (DF -52121), MMF-300-10 (DF -52347), MMF-302-6 (DF -52356), SD355/SD355T (DF -52384), and SLC Wiring Manual (51309). NOTE: Legacy 300 Series detection devices such as the CP300/CP350, SD300(T)/SD350(T) and older modules such as the M300, M301, M302, C304, and BG-10LX are not compatible with LiteSpeed polling. If the SLC contains one of these devices, polling must be set for standard CLIP protocol. Please consult factory for further information on previous 300 Series devices. ADDRESSABLE DEVICE ACCESSORIES End -of -Line Resistor Assembly (R -47K and R -3.9K): The 47k ohm assembly supervises the MMF-300, MDF -300, MMF-301, and CMF -300 module circuits. The 3.9k ohm assembly supervises the MMF-302 module circuit. These resistors are included with each module. Power Supervision Relay: Supervises the power to 4 -wire smoke detectors and notification appliances. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted -pair to minimize the effects of electrical interfer- ence. Refer to the panel manual for wiring details. DF -60953:C • 7/16/2016— Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity • Intelligent Signaling Line Circuits 1 • Addressable device capacity 50 • Programmable software zones 50 • Annunciators 16 Electrical Specifications AC Power: Operates in either 120 or 240 VAC, 50/60 Hz, 3.25 A, auto -sensing- no switch required. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Nonpower -limited, supervised. Battery: Two 12 V 18 AH lead -acid batteries. Battery Charger Capacity: 7-18 AH (ES -50X cabinet holds maximum of two 18 AH batteries.) Communication Loop: Supervised and power -limited. Notification Appliance Circuits: Terminal Block provides connec- tions for two NACs, Style Y (Class B) or Style Z (Class A). Special Application power. Power -limited, supervised circuitry. Maximum signaling current per circuit: 2.5 amps special application, 250mA regulated. End -of -Line Resistor: 4.7k ohm, 1/2 watt (P/N 71252 UL listed) for Style Y (Class B) NAC; system capable of 1.9 kit - 22 kit ELR range. Refer to the Fire•Lite Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Con- tact rating: 2.0 A © 30 VDC (resistive), 0.5 A @ 30 VAC (resistive). Form -C relays, non -power -limited, non -supervised. Cabinet Specifications Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR -CE): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 — 49°C/32 — 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 — 27°C/60 — 80°F. NFPA Standards The ES -50X complies with the following NFPA 72 Fire Alarm Sys- tems requirements: — LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi- sory). — AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). — REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervi- sory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) — PROPRIETARY (Automatic, Manual and Waterflow). — CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). — OT, PSDN (Other Technologies, Packet -switched Data Net- work) — IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seismic). — CBC 2007 (Seismic) Agency Listings and Approvals The listings and approvals below apply to the basic ES -50X control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL: S624 • FM approved • CSFM: 7165-0075:0500 • FDNY: COA #6261 NOTE: See DF -60954 for ULC -listed model. AlarmNet®, Fire -Lite® Alarms, SWIFT®, and System Sensor® are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. 02018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 C E R T 1 F 1 E 0 MMMOIMi E MMM !AIME IIAIITY SYSTEMS This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Country of Origin: USA Page 4 of 4 — DF -60953:C • 7/16/2018 SD355(A) Series Addressable Photoelectric Smoke Detectors DF -52384:D • E-160 Flre•uTemarms by Honeywell Addressable Devices General The SD355(A), SD355T(A), and SD355R(A) addressable, low -profile plug-in photoelectric detectors use a state-of-the- art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with Fire•Lite's Addressable Fire Alarm Control Panels (FACPs). The SD355T(A) adds thermal sensors that will alarm at a fixed temperature of 135°F (57°C). Since these detectors are addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indica- tion. Remote LED annunciator capability is available as an optional accessory, PN RA100Z(A). The SD355R(A) is a remote test capable detector for use with D355PL(A) or DNR(A)/DNRW duct smoke detector housings. Features SLC LOOP • Two -wire loop connection. • Unit uses base for wiring. ADDRESSING • Addressable by device. • Rotary, decimal addressing: 01 – 99 with MS-9200UD(LS), and 01 –159 with MS-9600UD(LS). ARCHITECTURE • Unique single -source, dual-chamber design to respond quickly and dependably to a broad range of fires. • Sleek, low -profile design. • Integral communications and built-in type identification. • Built-in tamper-resistant feature. • Removable cover and insect -resistant screen for simple field cleaning. OPERATION • Withstands air velocities up to 4,000 feet -per -minute (20 m/ sec.) without triggering a false alarm. • Factory preset at 1.5% nominal sensitivity for panel alarm threshold level. • Visible LED "blinks" when the unit is addressed (communi- cating with the fire panel) and latches on in alarm. MECHANICALS • Sealed against back pressure. • Direct surface mounting or electrical box mounting. • Mounts to: single -gang box, 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box, or 4.0" (10.16 cm) square electrical box (using a plaster ring — included). OTHER SYSTEM FEATURES • Fully coated circuit boards and superior RF/transient pro- tection. • 94 -VO plastic flammability rating. • Low standby current. SD355(A) in B210LP(A) Base OPTIONS • Remote LED output connection, PN RA100Z(A). 2151_2251 B_CEILI NG.prg Applications Use photoelectric detectors in life -safety applications to pro- vide a broad range of fire -sensing capability, especially where smoldering fires are anticipated. Ionization detectors are often better than photoelectric detectors at sensing fast, flaming fires. Construction These detectors are constructed of off-white fire resistant plas- tic. SD355(A) series plug-in, low -profile smoke detectors are designed to commercial standards and offer an attractive appearance. Installation SD355(A) series plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DF -60059. NOTE: Because of the inherent supervision provided by the SLC loop, end -of -line resistors are not required. Wiring "T -taps" or branches are permitted for Style 4 (Class B) wiring. SD355R(A) mounts in a D355PL(A) or DNR(A)/DNRW duct detector housing. Operation Each SD355(A) series detector uses one of 99 possible addresses on the MS-9200UD(ILS) and up to 318 (159 on each loop) on the MS-9600UD(LS) Signaling Line Circuit (SLC). It responds to regular polls from the system and reports its type and status. The addressable photoelectric sensor in the SD355(A) series has a unique unipolar chamber that responds quickly and uni- formly to a broad range of smoke conditions. It can withstand wind gusts up to 4,000 feet -per -minute (20 m/sec.) without sending an alarm level signal. Because of its unipolar cham- ber, the SD355(A) series is approximately two times more responsive than most photoelectric sensors. This makes it a more stable detector. DF -52384:D • 2/11/2015 — Page 1 of 2 Detector Sensitivity Test Each detector can have its sensitivity tested (required per NFPA 72, Chapter 14 on Inspection, Testing and Maintenance) when installed/connected to a MS-92000D(LS) or MS- 96000D(LS) addressable fire alarm control panel. The results of the sensitivity test can be printed off the MS-92000D(LS) or MS-96000D(LS) for record keeping. Specification Voltage range: 15 — 32 VDC (peak). Standby current: 300 pA @ 24 VDC. LED current: 6.5 mA CO 24 VDC (latched "ON"). Air velocity: 4,000 ft./min. (20 Msec.) maximum. Size: 2.1" (5.33 cm) high; base determines diameter. — B210LP(A): 6.1" (15.5 cm) diameter. — B501(A): 4.1" (10.4 cm) diameter. — B200SR(A): 6.875" (17.46 cm) diameter. — B224RB(A): 6.2" (15.748 cm) diameter. Weight: 3.6 oz. (102 g). Operating temperature range: for SD355(A): 0°C to 49°C (32°F to 120°F); for SD355T(A): 0°C to 38°C (32°F to 100°F). SD355R(A): installed in a DNR(A)/DNRW -20°C to 70°C (-4°F to 158°F). Temperature: 0°C — 49°C (32°F — 120°F). Relative humidity: 10% — 93%, non -condensing. Listings Listings and approvals below apply to the SD355(A), SD355T(A), and SD355RT(A) detectors. In some cases, cer- tain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL Listed: S1059. • ULC Listed: S1059. • CSFM: 7272-0075:0194. • MEA: 243-02-E. • FM approved. Product Line Information NOTE: "A" suffix indicates ULC Listed model. SD355: Addressable photoelectric detector; B210LP base included. SD355A: Sames as SD355 with ULC Listing; B210LPA base included. SD355T: Same as SD355 but with thermal element; B210LP base included. SD355TA: Same as SD355T with ULC Listing; B210LPA base included. SD355R: Remote test capable addressable photoelectric detector for use with a D355PL(A) or DNRA/DNRW duct detector housing; B210LP base included. SD355RA: Same as SD355R with ULC Listing for use with a D355PLA or DNRA duct detector housing; B210LPA base included. INTELLIGENT BASES NOTE: "A" suffix indicates ULC Listed model. NOTE: The detector's plug-in base can be changed off for special applications. For details about intelligent bases and their mount- ing, see DF -60059. B210LP(A): Plug-in detector base (included); standard U.S. flanged low -profile mounting base. B210LPBP: Bulk pack of B210LP; package contains 10. B501(A): Standard European flangeless mounting base. B501BP: Bulk pack of B501; package contains 10. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces 8501 BH series bases in retrofit applications. B224RB(A): Plug-in System Sensor relay base. Screw termi- nals: up to 14 AWG (2.0 mm2). Relay type: Form -C. Rating: 2.0 A 0 30 VDC resistive; 0.3 A 0 110 VDC inductive; 1.0 A 0 30 VDC inductive. B224BI(A): Plug-in System Sensor Isolator detector base. Maximum 25 devices between isolator bases (see DF -52389). ACCESSORIES F110: Retrofit flange to convert B210LP(A) to match the B350LP(A) profile, or to convert older high-profile bases to low -profile. F110BP: Bulk pack of F110; package contains 15. F210: Replacement flange for B210LP(A) base. RA100Z(A): Remote LED annunciator. 3 — 32 VDC. Mounts to a U.S. single -gang electrical box. For use with B501(A) and B210LP(A) bases only. SMB600: Surface mounting kit M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applica- tions. XP -4: Extension pole for XR2B. Comes in three 5 -foot (1.524 m) sections. T55-127-010: Detector removal tool without pole. BCK-200B: Black detector covers for use with SD355(A) only; box of 10. WCK-200B: White detector covers for use with SD355(A) only; box of 10. FlreLlte® Alarms is a registered trademark of Honeywell International Inc. ®2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 C E R T I F I E D BMW E MMMIM IMU IhAIIT? SYSTEMS This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2 — DF -52384:D • 2/11/2015 MMF-300(A) Series, MDF -300 Addressable Monitor Modules DF -52121:E • E-325 Fl re-UTe®ALarms by Honeywell Addressable Devices General Four different monitor modules are available for Fire•Lite's intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry -contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two -wire smoke detectors (MMF-302(A)). MMF-300(A) is a standard -sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry -contact input devices. MMF-301(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.65" (1.651 cm) D that super- vises a Style B (Class B) circuit of dry -contact input devices. Its compact design allows the MMF-301(A) to be mounted in a single -gang box behind the device it monitors. MMF-302(A) is a standard -sized module used to monitor and supervise compatible two -wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. MDF -300(A) is a standard -sized dual monitor module used to monitor and supervise two independent two -wire Style B (Class B) dry -contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two -wire sys- tems. LiteSpeedTM is a communication protocol developed by Fire•Lite Engineering that greatly increases the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other communication protocols. MMF-300(A) Monitor Module • Built-in type identification automatically identifies this device as a monitor module to the control panel. • Powered directly by two -wire SLC loop. No additional power required. • High noise (EMF/RFI) immunity. • SEMS screws with clamping plates for ease of wiring. • Direct -dial entry of address: 01 — 159 on MS -9600 series panels, 01 — 99 on other compatible systems. • LED flashes during normal operation and latches on steady to indicate alarm. The MMF-300(A) Monitor Module is intended for use in intelli- gent, two -wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two -wire or four -wire fault-tolerant Initiating Device Circuit (IDC) for normally -open -contact fire alarm and supervisory devices. The module has a panel -controlled LED indicator. The MMF-300(A) can be used to replace M300(A) modules in existing systems. MMF-300(A) APPLICATIONS Use to monitor a zone of four -wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally - open dry -contact alarm activation devices. May also be used to monitor normally -open supervisory devices with special CORM PATON ACCPAPDAI COMPIANCIAL PAINTAIATAAP xcH", IMAM KAM. n SUP (1 aci•In MAI.. AN AMP= MATALLATIONOMIN1PPANA ILL PAT MO SAYAN naw•Iq MMF-300(A) (Type H) supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K Ohm End -of -Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. MMF-300(A) OPERATION Each MMF-300(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-300(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 375 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MMF-301(A) Mini Monitor Module • Built-in type identification automatically identifies this device as a monitor module to the panel. • Powered directly by two -wire SLC loop. No additional power required. • High noise (EMF/RFI) immunity. DF -52121:E • 07/30/2015 — Page 1 of 4 • Tinned, stripped leads for ease of wiring. • Direct -dial entry of address: 01 — 159 on MS -9600 series panels, 01 — 99 on other compatible systems ADDRESS 2 3 4 5 9 8 7 6 TENS LOOP The MMF-301(A) Mini Monitor Module can be installed in a single -gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The MMF-301(A) is intended for use in intelligent, two -wire systems where the individual address of each module is selected using rotary switches. It provides a two -wire initiat- ing device circuit for normally -open -contact fire alarm devices. The MMF-301(A) can be used to replace M301(A) modules in existing systems. MMF-301(A) APPLICATIONS Use to monitor a single device or a zone of four -wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally -open dry -contact devices. May also be used to monitor normally -open supervisory devices with special supervisory indication at the control panel. Monitored circuit/ device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K Ohm End -of -Line Resistor (provided) terminates the circuit. MMF-301(A) OPERATION Each MMF-301(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). MMF-301(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 450 pA. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. MMF-302(A) Interface Module • Supports compatible two -wire smoke detectors. • Supervises IDC wiring and connection of external power source. • High noise (EMF/RFI) immunity. • SEMS screws with clamping plates for ease of wiring. • Direct -dial entry entry of address: 01 — 159 on MS -9600 series panels, 01 — 99 on other compatible systems. • LED flashes during normal operation. • LED latches steady to indicate alarm on command from control panel. The MMF-302(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two - wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two -wire detectors being monitored must be UL compatible with the module. The MMF-302(A) can be used to replace M302(A) modules in existing systems. MMF-302 (A) APPLICATIONS Use the MMF-302(A) to monitor a zone of two -wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K Ohm End -of -Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across terminals 8 and 9 for Style D application. MMF-302(A) OPERATION Each MMF-302(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-302(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 Ohms. Average operating current: 270 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K Ohms. External supply voltage (between Terminals T10 and T11): • DC voltage: 24 volts power limited. • Ripple voltage: 0.1 Vrms maximum. • Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MDF -300(A) Dual Monitor Module The MDF -300(A) Dual Monitor Module is intended for use in intelligent, two -wire systems. It provides two independent two - wire initiating device circuits (IDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel - controlled LED. Page 2 of 4 — DF -52121:E • 07/30/2015 NOTE: The MDF -300(A) provides two Style B (Class B) IDC cir- cuits ONLY. Style D (Class A) IDC circuits are NOT supported in any application. MDF -300(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non -condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MDF -300(A) AUTOMATIC ADDRESSING The MDF -300(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the MDF -300(A) is set to address "26", then it will automati- cally assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the MDF -300(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation MMF-300(A), MMF-302(A), and MDF -300(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface -mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regu- lations. These modules are intended for power -limited wiring only. The MMF-301(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL: S2424. • ULC: S2424. • FM Approved. • CSFM: 7300-0075:0185. • MEA:72-01-E. Product Line Information NOTE: "A" suffix indicates ULC -listed model. MMF-300(A): Monitor module. MMF-301(A): Monitor module, miniature. MMF-302(A): Monitor module, two -wire detectors. MDF -300(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface -mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51309. Architects'/Engineers' Specifications Specifications of these devices and all FireLite products are available from FireLite. DF -52121:E • 07/30/2015 — Page 3 of 4 Fire.Lite® is a registered trademark and LiteSpeedT'" and FireWatchT" are trademarks of Honeywell International Inc. ©2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 C E R T I F I E D MUMMY MIMI I AU/MUtilaIM QUALITY SYSTEMS This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire•Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4 — DF -52121:E • 07/30/2015 ACCEPTED O Without Comments g As Noted in Red O Per The Attached Letter These plans have been reviewed by The Tukwila Fire -evention Bureau ..r,, : or formance wail current City -;ndards. Accepr:-. + subject to errors and ,fissions which c ithortze violations of adopted andards and Qrc,. •;.a :cos. The responsibility for the :,equacy of destctoz f °t..: totally with the designer. dltions, deietiont : n:,,,€cions to these drawings after mis date will voto tht:: '::eptance and will require a resubmittal 'f ri'zfwings for subsequent approval. Final acceptance is subject to held test and inspection by The Tukwila Fire Prevention Bureau. Date: -.)- - i � By: 4-v-1 _..:t.A FIRE DEPARTMENT „ ._ns;i 2C&575-4O7 �and 4.�AL1 L.y »!.icrt F14.Ja #;-SS for; 1ut- �` wn or re::toration 6ipprovaa.