HomeMy WebLinkAboutPP - 5218 204TH ST - SEGALE STORM WATER FACILITY - PERMITS AND PLANS5218-5698 204TH ST ASSOCIATED PERMITS 11-F-177 Washington Alarm Inc. 1253 S. Jackson Street Seattle, WA 98144 Phone: 206-328-3288 Fax: 206-322-7214 www.washingtonalarm.com FIRE ALARM SYSTEM SUBMITTALS FOR SEGALE STORM WATER FACILITY 5218-5698 South 204th Street Tukwila, Washington 98032 July 27`h, 2011 UL LISTED AND FM APPROVED CENTRAL STATION LICENSED AND BONDED ELECTRICAL CONTRACTOR CONFIDENTIAL A FIRE ALARM SYSTEMS BATTERY CALCULATION CHART B C D E F Form: 1/22/01 G NMA WASHINGTONALARM DEVICE/ MODULE MODEL NUMBER QUANTITY OF DEVICE/ MODULE STANDBY CURRENT (AMPS) TOTAL STANDBY CURRENT (CxD) ALARM CURRENT (AMPS) TOTAL ALARM CURRENT (CxFI Segale Storm Water Facility CONTROL PANEL AND MODULES SD505APS 4 0.00055 0.0022 0.00055 0.0022 Silent Knight Fire Alarm Panel 5700 1 0.2 0.2 0.325 0.325 Pull Station SD500PS 0 0 0 0 0 0 0 0 0 Battery 12 Volts -7.5 Amps SLA -1075 2 0 0 0 0 0 0 0 0 0 0 0 0 INITIATING DEVICES Smoke Detector SD505APS 4 0.00055 0.0022 0.00055 0.0022 Heat Detector SD500AH 2 0.00055 0.0011 0.00055 0.0011 Pull Station SD500PS 2 0.00055 0.0011 0.00055 0.0011 0 0 0 0 0 0 0 0 0 0 NOTIFICATION APPLIANCES Horn/ Strobes P2CR 3 0.212 0.636 Exterior Horn/Strone P2RHK 1 0.235 0.235 0 0 0 0 0 0 0 0 0 0 r Sum Column For Standby Load (Amps) Multiply By Required Standby Time (24 or 60 Hours) Total Standby AH 0.204 24 4.906 (G) Sum Column For Alarm Load (Amps) Multiply By Required Alarm Time (5 min = .083) Total Alarm AH 1.200 0.083 0.100 TOTAL TOTAL REQUIRED SAFETY TOTAL TOTAL STANDBY ALARM AH AH (G+H) FACTOR SYSTEM SYSTEM AH (G) (H) (Multiply) AMPERE- AMPERE - HOURS HOURS REQUIRED PROVIDED 4.906 0.0996332 5.005 1.3 6.507 I 15AH (H) CONFIDENTIAL A FIRE ALARM SYSTEMS BATTERY CALCULATION CHART B C D E F Form: 1/22/01 G ---� rVia. WAS H I N GTO NALARM DEVICE/ MODULE MODEL NUMBER QUANTITY OF DEVICE/ MODULE STANDBY CURRENT (AMPS) TOTAL STANDBY CURRENT (CXDI ALARM CURRENT (AMPS) TOTAL ALARM CURRENT (CxFI Segale Storm Water Facility -AES CONTROL PANEL AND MODULES 0 0 AES Radio transmitter 7788F 1 0.15 0.15 1.2 1.2 AES Intellitap 7067 1 0.06 0.06 0.1 0.1 0 0 Battery 12 VOLTS SLA1075 1 0 0 0 0 0 0 0 0 0 0 0 0 Sum Column For Standby Load (Amps) Multiply By Required Standby Time (24 or 60 Hours) Total Standby AH 0.210 24 5.040 (G) Sum Column For Alarm Load (Amps) Multiply By Required Alarm Time (5 min = .083) Total Alarm AH 1.300 0.083 0.108 TOTAL TOTAL REQUIRED SAFETY TOTAL TOTAL STANDBY ALARM AH AH (G+H) FACTOR SYSTEM SYSTEM AH (G) (H) (Multiply) AMPERE- AMPERE - HOURS HOURS REQUIRED PROVIDED 5.040 I 0.1079 5.148 1.3 I 6.692 7.5AH (H) �� SYSTEM '' 1mises: Circuit: .jale Storm Water Facility Class B @ 16 AWG 5218-5698 South 204th Street Filtered (DC) 24 -volt Supply (1.5 amp circuit) Tukwila, WA 98032 Starting Voltage = 20.4 Prepared By: Mark Mcllwain Washington Alarm Inc. 1253 S. Jackson Street Seattle, WA 98144 206-328-3288 Notes: Type and Model Candela Current Next Total 12 14 16 18 Wall Horn/Strobe (2 Wire) P2RHK 135 0.245 2.5 2.5 20.39 20.39 20.38 20.36 Ceiling Horn/Strobe (2 Wire) PC2R 110 0.212 38 40.5 20.29 20.23 20.13 19.97 Ceiling Horn/Strobe (2 Wire) PC2R 110 0.212 36 76.5 20.23 20.13 19.98 19.73 Ceiling Horn/Strobe (2 Wire) PC2R 110 0.212 29 105.5 20.21 20.10 19.91 19.63 Total current/amps 0.881 vdc loss 0.19 0.30 0.49 0.77 f Scaled at 14"=11 Insulated over- head door. 110CD A with remote indicator Amseco 1640-P Transformer See detail at right for FACP Zone & Telco connections Grounded per NEC standards / l J1 Serial port PROGILWW.PIN SET Grouni AES 7788F NP 7-12. 12V 7.0Ah Battery Signals will be transmitted in contact id format to Washington Alarms central station. Connects to J1 serial ( port on 7788F radio. a PROGRAMING PIN SET o°e .. t Pin 1 Is tempered for Ademco •. Contact ID format AES 7067 Intellitap on M try sm n RI Insulated over- head door. __l L� Clear -plastic pc curtain door. r with remote indicator Insulated over- head door. AC POWER INPUT I GD0 Ass V v O PREVIOUS REVIEW STATUS ALARM SUPERVISORY TROUBLE SILENCED POWER 0 0 0 0 RESET SILENCE ACK 1 4 7 2 5 8 0 3 6 9 0 0 ENTER LIi TERMINAL BLOCK 2 Form C Relays TELCO 1 PHONE 1 TELCO 2 PHONE 2 SK 5700 FACP TERM INAI.43LOCK 1 TROUBLE SLC IN SLC OUT SLC PRG SBUS PROGRAMMING PORT BATTERY CONNECTOR 0 NAC 1 NAC 2 4, -rn- -f 111- --rlr T- R g Ti, Ring Tip Ring Tip Ring Tip No Com NC - Hill- -fill- Hill- Hill- Hill- Hill- Hill- Hill- Hill - 4: - il-- + — + — + — + A B — + — + Alarm panel is addressable and all devices are on an SLC loop. Each devices functions as it's own End of Line resistor. FIRE ALA Alarms and troubles are sent to AES radio via 7067 IntelliTap interface. See diagram at left. AC Dedicated 110v power outlet. AES 7067 Intellitap M SYMBOL LEGEND FACP Dedicated 110v power outlet. AES 7788-F FACP SILENT KNIGHT 5700 FIRE ALARM CONTROL PANEL AES 7788F RADIO TRANSCEIVER SILENT KNIGHT 505APS ADDRESSABLE PHOTOELECTRIC SMOKE DETECTOR SILENT KNIGHT 505AHS ADDRESSABLE HEAT DETECTOR WITH REMOTE INDICATOR SILENT KNIGHT 500PS ADDRESSABLE MANUAL PULL STATION RISER DIAG SCOPE OF WORK: Install addressable fire alarm system consisting of four smoke detectors, two manual pull stations, two heat detectors to be installed in the attic with remote indicators below the ceiling tiles. Three horn/strobes and one exterior horn/strobe. AES Radio to transmit signals to the Central Station. WASHINGTON ALARM will provide the following: Runner service, Annual inspections, and Monitoring. TUKWILA FIRE DEPARTMENT Please call 206-575--1407 and give is_Fire � Permit rmit No. and exact address for shut- down or restcration approval. M ® Without Comments As No!`3d in Red Per The i =. ,r6..ac:hcd Letter ,se plans have been reviewed by The Tukwila Fire :Jf;iftion tBUreau for conformance vAth current City i_sards. Acf:ept:'r=r, is subject to errors and which cio r:: r i o IZe violations of adopted v : ards and orr inabce.. The responsibility for the f iiacy o e51g d .:: t'S�'i:C:tally with the designer. ;i Cdt�ats, rieleirion5 > f vi ;icn:a to these drawings after ii d_utc Wlii vola t.i'.i::, '.:.:;4:;t.c.rice and will require a i•;:mbbrnittai os ii Wirl ,;s for subsequent approval. Final acceptance is subject to field test -and inspection by The -Tukwila Fire Prevention Bureau. Date: H l ( By:. '>< Z'h 2 {c, 11 a S ((t- luotkc d4i-p o - t t , M . * rhssAll .C-1\4.'51447 k 1c legso-' NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing. PAID AUG --1 2011 TUKWILA FIRE WASH I NGTONALARM FACILITY SEGALE STORM WATER C\1 W M WCr F- 01) Cf) Z 2 O H H � C'3 CD Z c'fl=1 a CI)Cn Q co 0) la% CO Q Ln J H r c'J= V) I -- WASHINGTON ALARM WASHINGTONALARM INC. 1253 S. Jackson Street Seattle, WA. 98144 Designed by: Ryan Aal Drawn by: Mark Mcllwain Ph: 206-328-3288 Fax: 206-322-7214 REVISIONS DATE DESCRIPTION 07/28/2011 PERMIT SET FIRE ALARM FA -1 SITE LOCATION CITY OF TUIKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Site Address: 120 A ' `,� w-. King Co. Assessor's Tax No.:QV.30000 02 -- Suite Number: \0 Floor: I Tenant Name: L&%v bEl `. R �t_A of \J x New Tenant? [� - Yes tg_ No Property Owner's Name: 'riO /V ►€ (- Mailing Address 1 `t State Zip CONTACT PERSON -if there are questionssbout the submittal. Name: N�I'tk)e5/ Perrvtert,t/f r &(rys Company Name: i J'O O l*41`/ Mailing Address: /3A 15 [ii'dP ►1� City Day Telephone: Fax Number. State Zip Valuation of Project (contractor's bid price): S Z 1 -t OD Scope of Work (please provide detailed information): €A i_€,€ , (N) SW l` { 00 AllaiottoGe 7 cOv J(q v; is VALVE PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O * ' O . wy I RIZE ! AGENT: I -Lt. i, Signature: �' �',� _� .�� Print Name: `lf 4.41 06-1 Plan Permit App.doc Date: Day Telephone:. " 4 5c? 5357_ 5/14/10 TFD FP Form 8 G of an F (te o I `1