HomeMy WebLinkAboutPP - 6214 S 153RD ST - TERRA TUKWILA APARTMENTS - PERMITS AND PLANS6214 S 153RD ST ASSOCIATED PERMITS 18-F-222 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** Site Address: $ i 5-3 s4. King Co. Assessor's Tax No.: 3597000346 Suite Number: Floor: All Tenant Name: Terra Tukwila Apartments (formally San Juan AptS) Property Owner's Name: Pacific' Urhan Residential Mailing Address: 6216 S 153RD ST New Tenant? ❑ - Yes ® - No Tukwila WA 98188 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: George Washburn Day Telephone: 206-551-6435 Company Name: AAA FirP PrntPetinn, Inn Mailing Address: 3013 3rd Ave N Seattle WA 98188 City State Zip E-mail Address: george@aaafire.com Fax Number: Contractor's City' of Tukwila NICET III number: 125826 Business License number: BUS -09Q-3128 "Total number of new/relocated devices or sprinkler heads: 71 Valuation of Project (contractor's bid price): $ 71200 00 Scope of Work (please provide detailed information): PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing. one or more extensions of time. for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHIVAIDND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. vv BUILDING 0 ER OR AUTHORIZED�AGENT: Signature: . G/- a NOV 27 2018 TUKWILA FIRE Date: Print Name: George Washburn Day Telephone: 708-551-A435 11/27/2018 Plan Permit App doc 8/22/14 TFD FP Form 8 Sound Levels: Typical FACP Mounting Detail: Scope of Work Notes: Drawing Index NFPA 72, 18.4.3 2016 Edition To ensure that audible public mode signals are clearly heard, unless otherwise permitted by 18.4.3.2 through 18.4.3.5, they shall have a sound level at least 15 dB above the average ambient sound level or 5 dB above the maximum sound level having a duration of at least 60 seconds, withcever is greater, measured 1.5 m (5 ft) above the floor in the occupiable are, using A -weighted scale (dBA). NFPA 72, TABLE A18.4.3 2016 Edition Average Ambient Sound Level According to Location Location Average Ambient Sound Level (dBA) Business occupancies Educational occupancies Industrial occupancies Institutional occupancies Mercantile occupancies Mechanical rooms Piers and water -surrounded struchures Places of assembly Residential occupancies Storage occupancies Thoroughfares, high density urban Thoroughfares, medium density urban Thoroughfares, rural density urban Tower occupancies Underground structures and windowless buildings Vehicles and vessels 55 45 80 50 40 85 40 55 35 C 30 70 55 40 35 40 50 NFPA 72, 18.4.5 2016 Edition Sleeping Areas. 18.4.5.1 Where audible appliances are installed to provide signals for sleeping areas, they shall have a sound level of at least '15 db above the average ambient sound level or 5 db above the maximum sound level having a duration of at least 60 seconds or a sound level of at least 60 db, whichever is greater, measured at the pillow level in the occupiable area, —usiTtg--ttre-'A=weighted-sccrfe Bfr -PER-C ` a F SEATTLE REQUIREMENTS. 01 O Without Comments jir As Noted in Red O Per The Attached Letter These plans have been reviewed by The Tukwila Fire C rvention Bureau for conformance with current City ndards. Acceptance is subject to errors and nisslons which do not authorize violations of adopted ,ndards and ordinances, The responsibility for the Jequacy of design rests totally with the designer. ,dditions, deletions or revisions to these drawings after his date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance Is subject to field test and inspection by The Tukwila Fire Prevention Bureau.4-1"-N1 Date: 0--5 -1 3 By: ( fi.b1,1.-kt$11 b+vgke. 4,141,..r oh dkeJlea-Iwo FA- t vto.,e AR. d. I-P'Sof TUKWILA F P.E DEPARTMENT cr:,;i KG -575-1407 git; .2 E";`•3 o Periit . NO. exact r `F 3". s end cti�ci -.{� x:��...� for �rtlalty- f !own or ri e Zorat yon approval. FROM FIELD DEVICES Po TO FIELD DEVICES DEDICATED 120 VAC LABEL DEDICATED CIRCUIT FIRE ALARM SYSTEM " AND PLACE LOCK OUT ( FURNISHED ANDA PANELINSTAALTLEDYOTHERS r' " GROUND CIRCUIT " ( FURNISHED AND INSTALLED BY OTHERS ) FACP FIRE ALARM CONTROL PANEL Fire Alarm System Notes: 1. TESTING AND MAINTENANCE BY AM FIRE PROTECTION. 2. RUNNER SERVICE BY MA FIRE PROTECTION. 3. ALL WIRES AND SHIELDS TO BE FREE OF SHORTS AND GROUNDS. 4. ALL CONDUIT SHOULD BE SIZED PER NFPA 70 2014 (NEC). 5. THIS DRAWING SET DEPICTS GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT & FIELD DEVICES. EXACT ROUTING OF CONDUITS TO BE DETERMINED IN THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS. NFPA 72 2016 (SECTION 24.4.2.7(2)). 6. DUCT DETECTORS SHALL BE READILY ACCESSIBLE FOR SERVICING AND TESTING, PER NFPA 72 2016 (SECTION 17.7.5.5.3) AND SHALL BE MOUNTED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATION. 7. NFPA 72, AUDIBLE/VISUAL AND VISUAL ONLY DEVICES SHALL BE MOUNTED WITH THE ENTIRE LENS BETWEEN 80" AND 96" ABOVE THE FINISHED FLOOR (NFPA 72 2016 SECTION 18.5.4.1*). REFER TO EQUIPMENT DATA SHEETS FOR EXACT BACKBOX MOUNTING HEIGHTS. IF ADA APPLIES, STOBES SHALL BE MOUNTED AT 80" TO THE BOTTOM OF THE STROBE LENS (ADAG) 4.28.3 (6). 8. MANUAL PULL STATION SHALL BE NOT LESS THAT 3 1/2FT (1.1 M) AND NOT MORE THAN 4FT (1.37 M) FROM OPERABLE PART OF DEVICE TO FINISHED FLOOR LEVEL AND WITHIN 5FT OF DOORWAY OPENING, PER NFPA 72 2016 (SECTION 17.14.4). 9. FOR ALL ANCILLARY CONTROL INTERFACE RELAYS THAT INTERFACE TO EMERGENCY CONTROL DEVICES THAT REQUIRE (N.C.) CONTACTS, SHALL BE WITHIN 3'-0" OF THE EMERGENCY CONTROLLED DEVICE/CIRCUIT. FIELD COORDINATE EXACT LOCATION. CIRCUITS SHALL BE MONITORED FOR INTEGRITY. NFPA 72 2016 (SECTION 21.2.4 & 21.2.8). NOTE TO ELECTRICAL CONSTRUCTION CONTRACTOR REGARDING SCOPE: The Electrical Construction Contractor is to provide and install all low voltage conduit raceways, stub -ups and standard device mounting boxes with pull strings at each end of each open conduit. 120 VAC circuits and mounting of Owner Furnished control panel enclosures and specialty device back boxes, installed by others. The Owner and / or AAA Fire Protection shall supply, pull and terminate all low voltage specialty cable and trim out all control panels and field devices in addition to providing Special Systems equipment, design & engineering by NICET III / FPE, installation supervision & support, project management, trade coordination, software, programming, specialty communications, start-up, commissioning, certification and associated technical services, low voltage construction L&I permits and Fire / Life Safety Authority Having Jurisdiction (AHJ) approvals / permits as necessary for a complete and functional integrated system meeting all AHJ requirements. These systems are specifically designed around the Silent Knight Conventional System as engineered for Terra Tukwila applications by AAA Fire Protection to match the Terra Tukwila Electronic Safety & Security standards in order to minimize cost to Owner by allowing direct procurement, utilization of Terra Tukwila labor force where applicable. No Substitutions and No Exceptions. This up front Design / Assist approach and standardization simplifies operations and reduces costs through a common platform and maintains the required level of quality and consistency through common end user interface / operation, training, construction engineering, installation methods, graphics, formatting, programming sequences of operation, coordinated networked database, start-up / commissioning procedures and allows the owner to self -perform maintenance & operations, in-house site modifications I expansions, service, regularly scheduled confidence I functional testing & certifications, remote monitoring, control and system user management. For more information, design clarification or scope questions, please contact the Owner's AAA Fire Protection Consultant , George Washburn at phone # (206) 551-6435 or via email: george@aaafire.com. Sheet Number FDA -0.0 FDA -1.0 FDA -1.1 FDA -1.2 FDA -2.0 Sheet Title Cover Sheet and Fire Alarm System Notes First Floor Building Fire Alarm Plan Second Floor Building Fire Alarm Plan Third Floor Building Fire Alarm Plan Fire Alarm Battery Calculations & Fire Alarm Matrix & Fire Alarm Riser Diagram Vicinity Map: S 149th St 150th St S 152nd St L N 0 Tukwila Park Westfield Southcenter Baker Blvd Strander Blvd 6213 SOUTH 153RD STREET NORTH Fire Alarm Equipment List: Project Team: SYMBOL DESCRIPTION VENDOR / PART NUMBER ROUGH -IN BOX FACP FIRE 'ALARM CONTROL PANEL EXISTING FACTORY ENCLOSURE Device Mounting Heights: AES AES RADIO AES FACTORY ENCLOSURE CEILING MOUNTED SMOKE/HEAT DETECTOR NFPA 72 2016 (SECTION A.29.8.3.4(4)(B)) 36" FROM A BATHROOM DOOR. NFPA 72 2016 EDITION (SECTION 17.7.6.3.2) SHALL NOT BE LOCATED DIRECTLY IN THE AIRSTREAM OF SUPPLY REGISTER. 3' (MIN) NFPA 72 2016 EDITION (SECTION 18.5.4.6.2) HEARING IMPAIRED BEDROOM STROBE SHALL BE WITHIN (16') OF PILLOW & (24") TO THE TOP OF THE STROBE LENS AT 110cd OR USE 177cd. MORE THAN TWO APPLIANCES IN THE SAME ROOM OR ADJACENT SPACE WITHIN THE FIELD OF VIEW THAT FLASH IN SYNCHRONIZATION. FIELD OF VIEW IS 135' NFPA 72 2016 EDITION (SECTION 18.5.4.3.2(3)(4)) 18.5 4(73(4), NFPA 72 2016 EDJJION (SECTION 18.5.4.1*) ENTIRE LENS IS NOT LESS THAN (80") & NOT GREATER THAN (96") ABOVE THE FINISHED FLOOR. (ADAG) 4.28.3 (6) (80") ABOVE THE HIGHEST FLOOR LEVEL TO THE BOTTOM OF THE STROBE LENS. FINISHED FLOOR —\ NEVER HERE AUDIO/VISUAL & VISUAL -ONLY DEVICES / AUDIO -ONLY DEVICES NFPA 72 2816 EDITION (SECTION 18.4.8.1) SHALL HAVE THE TOPS ABOVE THE FINISHED FLOOR NOT LESS THAN (90") OR (6") BELOW FINISHED CEILING. SHALL BE MOUNTED MIDDLE AT (60") AFF (ADA) (48") MAX TO THE WORKING MECHANISM NFPA 72 2016 EDITION (SECTION 17.14.4) (42") MIN / (48") MAX TO THE OPERABLE PART IMPORTANT NOTE: CHECK WITH MANUFACTURE INSTALLATION SHEET FOR EXACT MOUNTING HEIGHT, LOCATION, BACK BOXES AND WIRING REQUIREMENTS. CEILING ACCEPTED HERE " NFPA 72 2016 EDITION (SECTION 17.6.3.13.11 CEILING MOUNTED HEAT DETECTOR MIN 4" FROM WALL, WALL MOUNTED HEAT DETECTOR MIN 4" TO 12" FROM CEILING TO THE BOTTOM • 0 NOTE: MEASUREMENTS SHOWN ARE TO THE CLOSEST EDGE OF THE DETECTOR. 4,, 12" (MAX) NFPA 72 2016 EDITION (SECTION 17.7.3.2.1 *) WALL MOUNTED SMOKE DETECTOR MAX 12" FROM THE CEILING TO THE TOP EDGE - DOOR WIDTH LESS 3" 6" MAGNETIC DOOR MANUAL HOLDER PULL STATION • 0 SIDE WALL FINISHED WALL ANNU ANNUNCIATOR SILENT KNIGHT FACTORY ENCLOSURE 0 HEAT DETECTOR SILENT KNIGHT - SK HEAT ROR CARLON PLASTIC SINGLE GANG NAIL -ON BOXES F MANUAL PULL STATION SK -PULL -SA CARLON PLASTIC SINGLE GANG NAIL -ON BOXES gki HORN STROBE SYSTEM SENSOR CARLON PLASTIC SINGLE GANG NAIL -ON BOXES FLOW/TAMPER SWITCH ADDRESSABLE INPUT MODULE SILENT KNIGHT EOL Re END -OF -LINE RESISTOR 4.7K OHM© 1/2 WATT MOUNT IN LAST DEVICE IN LINE 1 EARTH GROUND FURNISHED & INSTALLED BY OTHERS TELEPHONE LINES FURNISHED & INSTALLED BY OTHERS Tenant / Property Manager: TERRA TUKWILA 6213 SOUTH 153RD STREET TUKWILA, WA 98188 General Contractor: MA FIRE PROPTECTION 3013 3rd AVE N SEATTLE, WA FIRE ALARM SYSTEMS LEVEL III NICET NO. #125826 PHONE: 206-284-1721 GEORGE WASHBURN george@AAAFIRE.corn Designer of Record: AM FIRE PROPTECTION 3013 3rd AVE N SEATTLE, WA FIRE ALARM SYSTEMS LEVEL III NICET NO. #125826 PHONE: 206-284-1721 GEORGE WASHBURN george@AAAFIRE.com Subscriber: TERRA TUKWILA 6213 SOUTH 153RD STREET TUKWILA, WA 98188 120VAC FURNISHED & INSTALLED BY OTHERS Project Information: PARCEL: 359700-0346 PAS a NOV 27 2818 TUK `0`_F FIRE : 12/3, 322 -- FIRE PROTEC ON Revision Schedule # DESCRIPTION DATE ISSt IF FRR PERMIT 11'818 FIRE ALARM SYSTEMS COVER SHEET [erra Tul 153rd Steet, T IIIA FIRE PROTECTION Geor et Y+ $hdarn O it NICI i$ AN JOB NO.: PLOT DATE DATE: SCALE: DRAWN: CHCKD: SHEET NO.: FDA-O.O UNIT 15CD LAUNDRY I 115 MECHANICAL ROOM 117 I LOBBY 1 100 1 ELECTRICAL / RISER ROOM 118 0 75CD HALLLWAY II JSTAIRS UNIT I 103 I UNIT 1 104 I UNIT 1106 1 UNIT 1 108 1 75CD UNIT 1 105 I LEGEND 0 a —g— FACP, ANNU AREA NOT IN CONTRACT EXISTING PARTITION TO REMAIN HORN STROBE HEAT DETECTOR MANUAL PULL STATION MODULE FOR SPRINKLER WATER FLOW EXISTING FIRE ALARM CONTROL PANEL WITH AES RADIO ANNUNICATOR KEY NOTES 01 REFER TO COVER SHEET F0.0 FOR ADDITIONAL INFORMATION ON DEVICES AND FIRE ALARM SYSTEM. 75CD HALLLWAY UNIT 1 107 1 STAIR LOBBY UNIT I 109 SCALE: 1/8" = 1'-0" 0' 10' 20' FIRE PROTECTION Revision Schedule # DFRCRIPTION DATF FIRST FLOOR FIRE ALARM PLAN Terra Tul 6213 South 153rd Steet, T RRR FIRE PROTECTION 1 d r sire A$a M� I adu e (I ( , �, � VI * 14 rIN Y JOB NO.: PLOT DATE DATE: SCALE: DRAWN: CHCKD: SHEET NO.: FDA -1.0 UNIT 1202 I 75CD HALLLWAY I212I JSTAIRS LOBBY 12001 110CD \)J5 12101 UNIT UNIT 204 75CD j UNIT UNIT 1205 I UNIT I 208 1 LEGEND 521 FACP ANNU AREA NOT IN CONTRACT EXISTING PARTITION TO REMAIN HORN STROBE HEAT DETECTOR MANUAL PULL STATION EXISTING FIRE ALARM CONTROL PANEL WITH AES RADIO ANNUNICATOR KEY NOTES 01 REFER TO COVER SHEET F0.0 FOR ADDITIONAL INFORMATION ON DEVICES AND FIRE ALARM SYSTEM. HALLLWAY 213 75CD UNIT ( 207 I STAIRS I 211 LOBBY I 214 I UNIT I 209 I SCALE: 1/8" = 1'-0" 0' 10' 20' FIRE PROTECTION III III mormara' sommommummi fl. =aim , , milt ■�� IMIIII ■ ■ IIIIIIIIIIIIIIIIIIIIIIIIIIIII MN MIN ■ MINN ■IIIIIIIIIIIIIIIIIIIIIIII ■IIIIIIIIIIIIIIIIIIIIIIII II ■ ■ 111111111111111111111111111111 ��■■�MIII �■�■� MIN MIN MN SECOND FLOOR FIRE ALARM PLAN rul et, T i FIRE PROTECTWW;1 G�1arge Wq h ur`n ET �4 > .d M "v 1 ?A PA ryeq JOB NO.: PLOT DATE DATE: SCALE: DRAWN: CHCKD: SHEET NO.: FDA -1.1 • UNIT I 301 I UNIT 302 LOBBY I 300 75CD a STAIRS I 310 I HALLLWAY 312 UNIT I 303 1 UNIT 1304 I 75CD 1) UNIT 305 I UNIT I 308 I UNIT I 305 I LEGEND 521 0 FACP ANNU AREA NOT IN CONTRACT EXISTING PARTITION TO REMAIN HORN STROBE HEAT DETECTOR MANUAL PULL STATION EXISTING FIRE ALARM CONTROL PANEL WITH AES RADIO ANNUNICATOR KEY NOTES 01 REFER TO COVER SHEET F0.0 FOR ADDITIONAL INFORMATION ON DEVICES AND FIRE ALARM SYSTEM. 75CD HALLLWAY I 313 I UNIT I 307 I STAIR LOBBY I 314 I UNIT I 309 I SCALE: 1/8" = 1'-0" 0' 10' 20' FIRE PROTECTION Revision Schedule # f1PSCRIPTIfN MATE THIRD FLOOR FIRE ALARM PLAN Terra Tul 6213 South 153rd Steet, T III�I FIRE PROTECTION George Wa$htu1 ' ET �e y�w�r� �i J • i j NIi�ET 258 �; Mµr ddhsf.MMS" JOB NO.: PLOT DATE DATE: SCALE: DRAWN: CHCKD: SHEET NO.: FDA --1.2 SILENT' KNIGHT 6700 Battery Calculator (SK) Version 18.05.29 Panel ID: Location: 6700 Electrical room Ckt.# Circuit Name "Global Project Values: Project Name: Project ID: Prepared By: Date: Terra Tukwila George Washburn 111/25/2018 Standby Hours: Alarm Mins: Derating Factor: Voltage Drop Warning Threshold % Model: 6700 Add. Fire Alarm Control Panel Volts: 24 VDC Current draw Standby Alarm I 24 I 5 1.2 10 Max NAC Current: 2.5 Amps: Max Panel Current: 2.5 Amps;: AW Type G Ohms Per Length(ft) Actual 1000 Ft. One -Way Ohms Volts EOL %Drop 6700 6700 CTRL Panel 0.200 0.365 SK -PHOTO Photo, Photo -T, PhotoR 0.000 0.000 SK -HEAT Heat, Heat -HT, ROR 0.000 0.000 'SK =B Beam, Beam -T 0.000 0.000 SK DUCT Duct 0.000 0.000 SK -ACCLIMATE Acclimate 0.000 0.000 5K -FIRE -CO FIRE -CO 0.000 0.000 K -PHOTO - Photo W 0.000 0.000 SK -PHOTO -R Photo -R -W 0.000 0.000 SK -PHOTO -T - Photo -T -W 0.000 0.000 SK -HEAT Heat -W 0.000 0.000 SK-HEAT-ROR- Heat-ROR-W 0.000 0.000 SK -HEAT -HT - Heat -HT -W 0.000 0.000 SK-CONTRO Control 0.000 0.000 SK-CONTRO Control -6 0.000 0.000 SK -RE LAYMON-2 RelayMon-2 0.000 0.000 SK -MONITOR Monitor, Minimon 0.000 0.000 SK -MONITOR -2 Monitor -2 0.001 0.001 SKMONITOR-10 Monitor -10 0.000 0.000 SK -PULL -SAIDA SK -RELAY ''SIC -RELAY -6. SK -ZONE SK -ZONE -6 SK -ISO B224B1 B200SR B2o0S B200SR-LF B200S-LF B224RB RT 51 RTS KEY 00Z 6860 24 5496 5895X 865 - 6 5880 58 K -NIC SK -FML SK-FSL Pull -SA, Pull -DA Relay Relay -6 Zone Zone -6 NAC #1 NAG Isolator Module Isolator Base Sounder Base Intelligent Sounder Base Low Freq Sounder Base Low Freq Sounder Base Relay Base Magnetic Remote Test Key Activated Test Remote LED LCD Remote Annunc. LCD Remote Annunc. Power Expander Power Expander LED Annunciator (3G) LED Annunciator (4G) LED Driver Module Relay Module Network Input Card Muilti-Mode Fiber Card Single -Mode Fiber Card Notification Appl Circuit 0.002 0.002 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.035 0.145 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0 0.000 0.000 0 0.000 0.000 0.000 0.000 #12 Solid 9 200 0.64 20.40 0.00% Notification Appl Circuit 0.000 0.000 #12 Solid 9 100 0.32 20.40 0.00% Total Standby Current (Amps) 0.238 2.409 Standby Time In Hours 24 0.08 Total A Current (Amps) Alarm Time In Minutes 60 (5 Mins Total Standby AH Requirlsrl 5.719 0.201 Total Alarm AH Required Total Combined AH Required 5.92 ultiply By The Derating Facto 20 Command Shortcuts Project Information Project Name: Terra Tukwila Prepared By: George Washburn Project ID: 0 Date: 11/25/2018 Ckt. Number: NAC #1. Ckt.. Name: Notification Appl Circuit Panel ID: 6700 Use: Aux Power Circuit Qty Device Current Draw Each Current Draw Total Standby Alarm andby Alarm 6 System Sensor P2/PC2 Horn/Strobe (75cd) 0.000 0.176 0.000 1.056 System Sensor P2/PC2 Horn/Strobe (110cd) Unused 0.000 0.22 0.000 022 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 1.277 Ckt. Number: NAC #2 Ckt. Name: Notification Appl Circuit Panel ID: 6700 Usel Aux Power Circuit Qty Devic Current Draw Each Current Draw Total Standby Alarm Standby . Alarm 3 System Sensor P2/PC2 Horn/Strobe (75cd) 0.000 0.176 0.000 0.528 System Sensor P2/PC2 Horn/Strobe (15cd) 0.000 0,09. 0.000 0.09 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000, 0.000 0:000` 0.000 Totals 0.000 0.619 DEDICATED 120 VAC THIS IS A GUIDE LINE. VERIFY WITH AAA 8c OWNER FOR COMPLET FIRE ALARM SYSTEM MATRIX ANNUNCIATION FUNCTIONS NOTIFICATION FUNCTIONS AUX. CONTROL FUNCTIONS NOTES FIRE RESPONSE MATRIX 0 CAUSE Q V >` ..- i QO u--3 4 l O ct c) .. Q W O O Q' 0.. �' 2 `' �' I J Q' Ci Q v J Q z. 'ff. V' LZ. C) ci Cr) Oti FLOW SWITCH TAMPER SWITCH SYSTEM RESET SIGNAL SILENCE AC POWER FAILURE FACP LOW BATTERY ALARM INITIATING HEADS (EXCLUDING SMOKE HEADS IN UNITS) FIRE ALARM WIRING: SIGNALING LINE CIRCUIT (SLC) - CLASS B/LEVEL 1: SINGLE OPEN SINGLE GROUND WIRE -TO -WIRE SHORT INITIATING DEVICE CIRCUIT (IDC) - CLASS B/LEVEL 1: SINGI E OPEN SINGLF GROUND WIRE -TO -WIRE SHORT NOTIFICATION APPLIANCE CIRCUIT (NAC) - CLASS B/LEVEL 1: SINGLE OPEN SINGLE GROUND WIRE -TO -WIRE SHORT 41111.1.4110 4.00 OD 401 AES RADIO GENERAL NOTE: 1. CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE ALL PORTIONS OF THE DRAWINGS & SPECIFICATIONS. 2. CONTRACTOR SHALL REPORT TO ARCHITECT IMMEDIATELY WHEN ERROR OF INCONSISTENCY IS DISCOVERED BETWEEN THE DRAWINGS AND SPECIFICATIONS. ANNUNC LOBBY 100 75 15 FACP: 2-1 LOBBY 100 110 75 FACP: 2-2 LAUNDRY 115 75 1110 DEDICATED 120 VAC ELECTRICAURISER ROOM 116 FIRE ALARM CONTROL PANEL FACP: 1-1 OUTSIDE 75 FACP: 2-3 HALLWAY 112 75 FACP: 1-2 LOBBY 1200 I MEI FACP:2-4 FACP:2 HALLWAY 75 FACP: 1-3 HALLWAY 212 75 FACP: 1-4 HALLWAY 213 ELECTRICAL/RISER ROOM 116 100 002 ELECTRICAURISER 116 003 LOBBY 114 004 LOBBY 200 75 FACP: 1-5 LOBBY 1300 1 75 FACP: 1-6 HALLWAY C 005 312 FACP: 1-7 HALLWAY 1 313 I LOBBY 214 F EOL FACP: 1 006 LOBBY 300 FUNCTIONAL RISER DIAGRAM FIRE ALARM SYSTEM 007 LOBBY 1 3141 008 ELECTRICAURISER 116 FIRE PROTECTION Revision Schedule DFSCRIPTION DATF ISSLIF FOR PFRMIT >- WoSw I- CO CO aloox ce �<w< Q w� ct wit(0Ll. Terra Tukwila 6213 South 153rd Steet, Tukwila, WA 98188 JOB NO.: PLOT DATE DATE: SCALE: DRAWN: CHCKD: SHEET NO.: FDA -2.0