Loading...
HomeMy WebLinkAboutPP - 4344 S 104TH PL - HERZOG GLASS - PERMITS AND PLANS4344 S 104TH PL ASSOCIATED PERMITS 13-S-173 08-S-59 HERZOG GLASS CASCADE ALARM SITE LOCATION Site Address: Tenant Name: CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** 13 t( S /0y-1 p/ King Co. Assessor's Tax No.: /11e/ c)9c%5 Property Owner's Name: 5 H I f 2ert / r 5 1r r► Suite Number: if Floor: New Tenant? El - Yes '- No Mailing Address: City State Zip CONTACT PERSON-if there are questions about the submittal. / Name: /2L-[ cl 6 d Company Name: (--,4 5-051-0' P fl69c2j -245-9 Mailing Address: E-mail Address: Day Telephone: Z- 4 V //5i/ / City State Zip (i9SC P /1;4/24, r U, Fax Number: Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ 3 Z 0 / / / Scope of Work please provide detailed information): f `t 5-41- // O /Y e //jl 41 fi /' 9 V s / ad / %foo ni Pw eq e /2 4 c I( , _ PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 ORIZE ! • GENT: Signature: Print Name: Plan Permit App.doc Date: /7—/10 —7 3 Day Telephone:27 2 S / i` 1/2/13 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Herzog Glass 4344 S 104th PI Permit No.: 13-S-173 Date: July 22, 2013 Reviewer: Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 ' inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage teat results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • Maintain a 4 ft. clear space around the sprinkler riser for emergency access. • An electrically supervsed post indicating valve (PIV) is required. • PIV shall have the building number served by the PIV stenciled vertically in 3 - inch high white numbers on a "safety red" background, facing the direction of vehicular access. • The height of the fire department connection (FDC) shall be 36 to 48 inches above grade. • The FDC shall have a downward angle bend of 30 degrees with a 5 -inch Storz connection and a Kncx locking Storz cap. • Install listed water shields on in -rack sprinklers. • Installation of all electrical pre -action system components requires a separate fire alarm permit and an electrical permit. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. Thes Preyc stand orris: stand adeq Addie this d resui Final Ttie Date A TUKWILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No, GENERAL NOTES I . DESIGN AND INSTALLATION SHALL CONFORM TO NFPA PAMPHLET 13 AND CITY OF KENT REQUIREMENTS. 2. ALL MATERIALS SHALL BE NEW AND U.L. APPROVED. 3. PIPE: ALL PIPE 2' AND SMALLER TO BE SCHEDULE 40 BLACK STEEL. ALL PIPE 2? AND LARGER TO BE SCHEDULE I 0 BLACK STEEL, 4. FITTINGS: ALL FITTINGS (SCREWED AND GROOVED) AND GROOVED COUPLINGS TO BE DUCTILE IRON. 5. PAINTING OF PIPE AND PROTECTION OF SPRINKLER HEADS FROM PAINT IS BY OTHERS. G. ALL ELECTRICAL WIRING AND CONDIUT TO BE PROVIDED AND INSTALLED BY OTHERS. 7. NOT USED 8. OWNER I5 RESPONSIBLE TO ASSURE THAT STRUCTURE AS IT I5 SHOWN ON THE CONTRACT DRAWINGS CAN ADEQUATELY SUPPORT ALL FIRE SPRINKLER PIPING LOADS. NO AUXILUARY DEVICES OR ATTACHMENTS SHALL BE PROVIDED BY CASCADE TO SUPPUMENT THE STRUCTURE TO ACCOMODATE FIRE SPRINKLER PIPING LOADS, 9. CASCADE ALARM ASSUMES NO RESPONSIBILITY, EITHER EXPRESSED OR IMPLIED, FOR THE CONDITION, PERFORMANCE OR CURRENT CODE COMPLIANCE OF THE EXISTING SYSTEM TO BE MODIFIED OR ANY OTHER EXISTING FIRE PROTECTION SYSTEM ON SITE EXCEPT FOR WORK PERFORMED DIRECTLY BY CASCADE ALARM. 10. NOT USED 1 I . ALL DIMENSIONS ARE TO CENTERLINE OF PIPE. 12. DOTTED LINES DENOTE EXISTING PIPE. I3. SYMBOLS/ABREVIATIONS: X' -X` DENOTES CENTER LINE OF SPRINKLER PIPE APF. - DENOTES CEILING HEIGHT. AFF - CENTERLINE OF PIPE ABOVE FINISHED FLOOR. BDK - CENTERLINE OF PIPE BELOW BOTTOM OF DECK. OF - FLEXIBLE GROOVED COUPLING. MT - MECHANICAL TEE FD - FLEXABLE DROP NIPPLE. SEE PLAN FOR LEGNTH. J-- THREAD END PLUG Al - HYDRAULIC REFERENCE NODE. 6' UNISTRUT BOLT TO STRUCTURE 1000 CLAMP LINE (E) UPPRIGHT STRUCTURE HANGER DETAIL #1 Vicinity Map • CONTRACT NAME: Herzog Glass IMPORTANT in localities subject to freezing conditions, it is the owner's responsibility to provide heat throughout wet pipe sprinkler systems areas and in enclosures for dry pipe deluge and other types of valves controlling water supplies to sprinkler systems. This drawing and the information and design application herein contained is the property of Cascade Alarm, and is loaned upon express conditions that the same be returned to Cascade Alarm upon request; all information herein contained shall be treated as secret, and confidential; no reproduction of this drawing or any part thereof shall be made without written consent of Cascade Alarm. CONTRACT RESPONSIBILITIES SPRINKLERS ITEM CASCADE OTHERS TYPE I ORIFICE TEMP. FiNISH TY -FRB J 1/2" 155 BRASS CANOPY SYMBOL QTY. V 8 SYSTEM TYPE WET ® •___❑ ❑ 0 Cascade. Alarm 4344 S 104th PI Suite A Seattle, WA. 98178 CONTRACT. WITH: SCALE: 1/4"=1'-0" DRAWN BY: REID DESCRIPTION: PIPING PLAN CHECKED BY: NO. @U DATE BY REVISIONS - SEE FLAGGED AREA ON PLAN ELTA TOTAL THIS SHEET 8 APPROVALS ❑ OUT 0 IN OUT IN OUT IN OUT IN FIRE PROTECTION DIVISION Post Office. Box 7459, Kent, WA. 206-767-5800, Ext 2 SYSTEM DESIGN DATA DATE: 7/12/17 HAZARD f`I &&4KICA11r114. SYSTEM AREA: HYDRAUUC DENSITY: IWSIGN DATA GPM/SQ. FT. SO. FT./HD. AREA OF APPUCATION: so. FT• All WAN/:FS! GPM TOTAL SYSTEM RFOUIRFMENTS: GPM. AT: PSI. AT : WATER SUPPLY INFORMATION: STATIC PRESSURE PSI. DRAWING NO. FP 1 RESIDUAL PRESSURE : PSI. WITH GPM FLOWING TEST TAKEN AT BY DATE PAID JUL. 1.6 2013 t KWILA FIRE 13-5-/73 o without Comments ❑ As Noted in Red and exact address for shut- down or restoration approval CSZ Per The Attached Letter plans have beer, reviewed by The Tukwila Fire iition Bureau tc.i conformance with current City ards. Accor::n ce is subject to errors and mw.M lOt' 9 lions which czc no a.utnorize vioiacians of adopted lards and ord,;,ances. The responsibility for the / Marcy' O! f:Y3.4fri t x sts totaliy with the designer, ions, ck?le'•-iof : or revisions to Mese drawings after late wt'I void t!?i ',c,,:eptanc and will require a drawings for approval. rriittai of r :vised subsequent "ukwi a iIs subjectratio to field test and inspection ; 1, "ukwii4a Fire Prevention Bureau. 7-)...3 i S ( z y. I ie. -4 AlP LLiA WORI. — E E 6" — - - - - - - L_ J W I v? W o LL J LJ = LLJ o 4_,_I -I- L1.. J W = J o — - - L_ J LL! = -tom --1 0 o I Li__ J LTJ = • ___ _ - . 1 _ - 1 1/2 - . _-__ _(9. __ __ N AIM j / ? ( ) _NN nV c 2—q —3 5-3 5-3 , `ti+ 1 1/2 1 1/ 1 1/2 1 1/2 (E) LINES & MAINS AT ROOF (N) CQ\ SHELF I Uv I A el . SHELF U A. SHELF SHELF J LJ = 1---1 ____ ___ ..e_ ___ ___ W &______ e. _ ___ ___ ___ _e_—.F__e. co w ___ ___ ___ ___ tr. --- --- --- -e-_ --- --- --- ___ ___ _. (E) LINES & MAINS AT ROOF ___ ___ ___ _e_ ___ _1h__0. EXISTING OFFICE NO CHANGE ___ ___ ___ ___ ___ ----e---------- PIPING PLAN e_----( ----- - L L1 W GENERAL NOTES I . DESIGN AND INSTALLATION SHALL CONFORM TO NFPA PAMPHLET 13 AND CITY OF KENT REQUIREMENTS. 2. ALL MATERIALS SHALL BE NEW AND U.L. APPROVED. 3. PIPE: ALL PIPE 2' AND SMALLER TO BE SCHEDULE 40 BLACK STEEL. ALL PIPE 2? AND LARGER TO BE SCHEDULE I 0 BLACK STEEL, 4. FITTINGS: ALL FITTINGS (SCREWED AND GROOVED) AND GROOVED COUPLINGS TO BE DUCTILE IRON. 5. PAINTING OF PIPE AND PROTECTION OF SPRINKLER HEADS FROM PAINT IS BY OTHERS. G. ALL ELECTRICAL WIRING AND CONDIUT TO BE PROVIDED AND INSTALLED BY OTHERS. 7. NOT USED 8. OWNER I5 RESPONSIBLE TO ASSURE THAT STRUCTURE AS IT I5 SHOWN ON THE CONTRACT DRAWINGS CAN ADEQUATELY SUPPORT ALL FIRE SPRINKLER PIPING LOADS. NO AUXILUARY DEVICES OR ATTACHMENTS SHALL BE PROVIDED BY CASCADE TO SUPPUMENT THE STRUCTURE TO ACCOMODATE FIRE SPRINKLER PIPING LOADS, 9. CASCADE ALARM ASSUMES NO RESPONSIBILITY, EITHER EXPRESSED OR IMPLIED, FOR THE CONDITION, PERFORMANCE OR CURRENT CODE COMPLIANCE OF THE EXISTING SYSTEM TO BE MODIFIED OR ANY OTHER EXISTING FIRE PROTECTION SYSTEM ON SITE EXCEPT FOR WORK PERFORMED DIRECTLY BY CASCADE ALARM. 10. NOT USED 1 I . ALL DIMENSIONS ARE TO CENTERLINE OF PIPE. 12. DOTTED LINES DENOTE EXISTING PIPE. I3. SYMBOLS/ABREVIATIONS: X' -X` DENOTES CENTER LINE OF SPRINKLER PIPE APF. - DENOTES CEILING HEIGHT. AFF - CENTERLINE OF PIPE ABOVE FINISHED FLOOR. BDK - CENTERLINE OF PIPE BELOW BOTTOM OF DECK. OF - FLEXIBLE GROOVED COUPLING. MT - MECHANICAL TEE FD - FLEXABLE DROP NIPPLE. SEE PLAN FOR LEGNTH. J-- THREAD END PLUG Al - HYDRAULIC REFERENCE NODE. 6' UNISTRUT BOLT TO STRUCTURE 1000 CLAMP LINE (E) UPPRIGHT STRUCTURE HANGER DETAIL #1 Vicinity Map • CONTRACT NAME: Herzog Glass IMPORTANT in localities subject to freezing conditions, it is the owner's responsibility to provide heat throughout wet pipe sprinkler systems areas and in enclosures for dry pipe deluge and other types of valves controlling water supplies to sprinkler systems. This drawing and the information and design application herein contained is the property of Cascade Alarm, and is loaned upon express conditions that the same be returned to Cascade Alarm upon request; all information herein contained shall be treated as secret, and confidential; no reproduction of this drawing or any part thereof shall be made without written consent of Cascade Alarm. CONTRACT RESPONSIBILITIES SPRINKLERS ITEM CASCADE OTHERS TYPE I ORIFICE TEMP. FiNISH TY -FRB J 1/2" 155 BRASS CANOPY SYMBOL QTY. V 8 SYSTEM TYPE WET ® •___❑ ❑ 0 Cascade. Alarm 4344 S 104th PI Suite A Seattle, WA. 98178 CONTRACT. WITH: SCALE: 1/4"=1'-0" DRAWN BY: REID DESCRIPTION: PIPING PLAN CHECKED BY: NO. @U DATE BY REVISIONS - SEE FLAGGED AREA ON PLAN ELTA TOTAL THIS SHEET 8 APPROVALS ❑ OUT 0 IN OUT IN OUT IN OUT IN FIRE PROTECTION DIVISION Post Office. Box 7459, Kent, WA. 206-767-5800, Ext 2 SYSTEM DESIGN DATA DATE: 7/12/17 HAZARD f`I &&4KICA11r114. SYSTEM AREA: HYDRAUUC DENSITY: IWSIGN DATA GPM/SQ. FT. SO. FT./HD. AREA OF APPUCATION: so. FT• All WAN/:FS! GPM TOTAL SYSTEM RFOUIRFMENTS: GPM. AT: PSI. AT : WATER SUPPLY INFORMATION: STATIC PRESSURE PSI. DRAWING NO. FP 1 RESIDUAL PRESSURE : PSI. WITH GPM FLOWING TEST TAKEN AT BY DATE PAID JUL. 1.6 2013 t KWILA FIRE BOEING ACCESS ROAD S. SCALE: N.T.S. SPRINKLER PIPING PLAN N#TES 1. ALL NEW PI''ING SHALL BE SUPPORTED BY HANGERS PER N.F.P.A. 13. 2. NO PORTION OF THIS CONTRACTOR'S WORK IS TO BE COVERED OR CONCEALED BY ANY TRADE UNTIL SYSTEM RELOCATIONS HAVE BEEN ACCEPTED OR SIGNED OF BY TUKWILA FIRE DEPARTMENT. 3. " " DENOTES EXISTING SPRINKLER PIPING. 4. " " DENOTES NEW SPRINKLER PIPING. 5. ALL ELECT ICAL DONE BY OTHERS. 6. OWNER'S RESPONSIBILITY TO MAINTAIN HEAT AT OR ABOVE 40 DEGREES F. 2X8 WOOD JOIST 16" ON Q 1/4X0-21/2 WOOD SAMMY SCREW 318" A.T.R:--> 3/8" ROD BUTTON-----> PIPE HANGER RING---). SPRINKLER PIP ' SIDE MOUNTED WOOD SAMMY SCREW 4°'-- 3/8" A.T.R. #14 SCALE: N.T.S. SCOPE OF WORK 1. RELOCATE TWO HORIZONTEL SIDEWALL SPRINLER TO ACCOMADATE A WIDER DOOR. 2. RELOCATE TWO HORIZONTEL SIDEWALL SPRINKLER TO ACCOMADATE A TALLER DOOR. 32'-0" 440'-0" 4- — DEMI `rt. G WALL DEMISING WALL U, AI°,..ACENT TENANT as c1 1 1/2" 9 - 6" ' • WAREHOUSE EXISTING HORIZONTEL SIDEWALL IS TO BE RELOCATED DUE TO ROLL UP DOOR BEING ENLARGED BY 2'-0" 12'-0" .—EXISTING DOOR WIDTH EXIST. MAIN P4, I 30'-0" 32'-0" 1 LUNCHROOM CORRIDOOR coo — - mem ores 2 may_ v AREHOUSEi MOM ®. ..:11/4_ -o r EXISTING SSU 1 1/4 - o-_-_-0 r RELOCATE IDEWAL TO ACCOMADATE TALLER DOO — _{}_- — -0-- A.F.F. -O- — -0- — - •Glaanal - ®®0 - EXISTING SSU 1 OFFICE -0--- OFFICE 12'-0" r HORIZONTAL SIDEWALL %O- _z_ - -0 NEW DOOR -r-.0®_--0--0- OM= MUM IMINI — • NO CHANG S OFTICE OFFICE JAN. J --0-- OPEN OFFICES c -0 NEW ENLARGED DOOR WIDTH 14'-0" EXISTING DOOR TO BE ENLARGED TO 14"-D"WIDE 32'-0" 440'-0" 32'-0" 9 co DOOR HEIGHT CHANGED -4 4' '— TO 12`-10" N 3 l • • ACCEPTED Without Comments As Noted In Red Par The Attached Letter I nese plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. subject Acceptance is P .,t to errors and omissions which do not authorize violations of adopted steno arcs and ordinances. The reoonsibiltty for the adequacy of design rests totally with the designer. Adciti ms, deletions or revisions to these drawings atter tt this date will void this,acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The'Tukwila.Fire.Prevention Bureau. Date: 3 J D 2 By: 675 -- SCALE: 1/8" = 1'-0" HANGERS SPRINKLER HEAD SYMBOLS SPRINKLER DESCRIPTION SCOPE OF WORK APPROVALS & INSPECTION PHONE COPIES OCCUPANCY CONTRACT WITH 1. U -HOOK 2. COACH SCREW, ROD & RING 3. CEILING PLATE, ROD & RING 4. EYE ROD, WOOD SCREW & RING 5. EYE ROD, CONC. FASTENER & RING 6. QUICK BOLT, ROD & RING 7. POWDER DRIVEN STUD, ROD & RING 8. TOGGLE NUT, ROD & RING 9. RESTRAINER C -CLAMP, ROD & RING 10. TOP BEAM C -CLAMP, ROD & RING 11. TRAPEZE 12. SIDE BEAM BRACKET, ROD & RING 13. SHORT CLIP O-- UPRIGHT ON LINE 13— PENDENT ON LINE O— UPRIGHT ON STUB -UP --O DRY PENDENT SIDEWALL UPRIGHT & PENDENT TYPE SYM. TEMP QTY. HORIZONTEL SIDEWALL CHROME go 155 4 TOTAL ORDINARY GROUP ONE ADDRESS CITY PHONE WATER DEPT. ARCHITECT ADDRESS CITY PHONE ADDRESS CITY PHONE CASCADE ALARM LLC P.O. Box 7459 Kent, Wa. 98042 HERZOG iLASS COMPANY LINDAL INDUSTRIAL PARK TUKWILA, WA. HDS. THIS SHT JOB NO. DWG. NO. DRAWN DATE SCALE 1 OF 2/22/08AS NOTED i$ 46 'nY rtMWILA FIRE DEPARTME.ra Please call: 575-4407 and give this job No._ 0 5 and exact address for shut. down or restoration aDoro,,aE I