HomeMy WebLinkAboutPP - 4931 S 114TH ST - TUKWILA EDGE LLC - PERMITS AND PLANS4931 S 114TH ST ASSOCIATED PERMITS 19-S-131 SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION % JUN 2 5 2 y Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** FIRE REVEL IRE DEpT King Co. Assessor's Tax No.: Site Address: k S c—C-k\\ \ 4, Suite Number: Floor: 2— Tenant Name: U.,1 �C —VCcriZ ( L L New Tenant? ❑ - Yes ❑ - No Property Owner's Name: 1<‘n r \ i /A/ C Mailing Address: (a 22 C S' E 22 U City CONTACT PERSON -if there are questions about the submittal. Name: 1 S/Af c i/ Company Name: 1L(� S L C -- Mailing Address: ( 2 f co.y\l- KG -1 State Zip Day Telephone: 7 6)r ` City State Zip E-mail Address: V 1n'\ Q 3 �\ ' C Fax Number: Contractor's City of Tukwila NICET III number: Business License number: Total number of new/relocated devices or sprinkler heads: Valuation of Project (contractor's bid price): $ 30 O U Scope of Work (please provide detailed information): AtQz_s--, V t r\ A ^ S;4.1; PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. PAID BUILDING OWNER OR AUTHORIZED GENT: C 2319 Signature: Date: 6 \ � C TUKWILA FIRE C \ I Print Name: '[ I iv‘ /ii 1 '� Day Telephone:CD 2C3 c:7k` dO Plan Permit App.doc 8/22/14 TFD FP Form 8 NORCO FIRE PROTECTION, INC. 24024 SE 261ST PLACE MAPLE VALLEY, WA 98038 HYDRAULIC CALCULATIONS FOR PAK RESIDENCE LOT I TUKWILA, WASHINGTON FILE NUMBER: N 19052 DATE: 5/26/19 -DESIGN DATA - OCCUPANCY CLASSIFICATION: RESIDENTIAL DENSITY: RESIDENTIAL .05 gpm/sq. ft. AREA OF APPLICATION: 2 HEADS sq. ft. COVERAGE PER SPRINKLER: 16 X 16 sq. ft. NUMBER OF SPRINKLERS CALCULATED: 2 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 0 gpm TOTAL WATER REQUIRED (including hose): 26.7 gpm FLOW AND PRESSURE (@ BOR): 26.7 gpm @ 26.1 psi SPRINKLER ORIFICE SIZE: 7/16 inch NAME OF CONTRACTOR: NORCO FIRE PROTECTION, INC. DESIGN/LAYOUT BY: EDWIN P COGAR AUTHORITY HAVING JURISDICTION: TUKWILA FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: NORCOFPO I 5J0 WEB PUGET SOUND FIRE FIRE PREVENTION DEPT CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE # 501 10271) HRS SYSTEMS, INC. TUCKER, GA 30084 WAM*NOTON $TAT* CRIATIMICATE OV OOMPITENCY VIRE PROTECTION *PRNNRLIR SIMS** Edwin P. Cops <, 429534994G Level 3 'three file N SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 ,DATE: 5/28/2019 C:\HASS DATA\HASS\2019 CALCS\N19052 PAK RESIDENCE .SDF JOB TITLE: N19052 PK RESIDENCE WATER SUPPLY ANALYSIS G A U G E P 80.0 70.0 60.0 50.0 40.0 R E 30.0 S S U R E 20.0 Static: 70.00 psi Resid: 68.00 psi Flow: 50.0 gpm 10.OB p 0.0 s i -14.7 I I I I I I I I LEGEND 1 % Available pressure 69.38 psi @ 26.7 gpm 2 I Required pressure 47.17 psi @ 26.7 gpm A. Source Supply Curve B. System Demand Curve 20 30 40 50 60 70 80 90 100 FLOW (GPM) Note: (1) Dashed Lines indicate extrapolated values from Test Results SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 . DATE: 5/28/2019 C:\HASS DATA\HASS\2019 CALCS\N19052 PAK RESIDENCE .SDF JOB TITLE: N19052 PK RESIDENCE NFPA WATER SUPPLY DATA SOURCE NODE TAG A STATIC PRESS. (PSI) RESID. PRESS. (PSI) 70.0 68.0 AGGREGATE FLOW ANALYSIS: FLOW (GPM) 50.0 TOTAL FLOW AT SOURCE TOTAL HOSE STREAM ALLOWANCE AT SOURCE OTHER HOSE STREAM ALLOWANCES TOTAL DISCHARGE FROM ACTIVE SPRINKLERS NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE (FT) 1 2 3 4 5 6 7 8 W B C D E F A 21.0 21.4 21.0 21.4 20.4 20.4 10.4 9.4 9.4 0.0 0.0 0.0 3.0 3.0 0.0 K= 4.90 K= 4.90 SOURCE AVAIL. PRESS. (PSI) 69.4 TOTAL @ DEMAND (GPM) 26.7 GPM 0.0 GPM 0.0 GPM 26.7 GPM PRESSURE (PSI) 7.0 7.6 7.8 8.3 9.3 10.5 15.0 17.0 17.9 42.3 33.8 29.3 26.1 21.6 47.2 REQ'D PRESS. (PSI) 26.7 47.2 DISCHARGE NOTES (GPM) 13.0 13.7 26.7 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 5/28/2019 C:\HASS DATA\HASS\2019 CALCS\N19052 PAK RESIDENCE .SDF JOB TITLE: N19052 PK RESIDENCE NFPA PIPE DATA Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot.(Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 1 4.90 13.0 Disch 12.0 11.33 150 0.5 2 21.4 7.6 0.0 1.000 12.00 -0.2 1 21.0 7.0 13.0 1.101 23.33 0.031 0.7 Pipe: 2 0.0 0.0 5.0 1.29 150 0.2 3 21.0 7.8 3.1 1.000 5.00 0.2 2 21.4 7.6 3.1 1.101 6.29 0.002 0.0 Pipe: 3 4.90 13.7 Disch 7.0 8.00 150 0.6 4 21.4 8.3 3.1 2 1.000 7.00 -0.2 3 21.0 7.8 16.7 1.101 15.00 0.049 0.7 Pipe: 4 0.0 16.7 3 32.0 52.92 150 0.9 5 20.4 9.3 -11.4 7 1.000 32.00 0.4 4 21.4 8.3 5.4 1.101 84.92 0.006 0.5 Pipe: 5 0.0 0.0 27.0 40.17 150 1.7 5 20.4 9.3 9.9 1.000 27.00 0.4 2 21.4 7.6 9.9 1.101 67.17 0.019 1.3 Pipe: 6 0.0 9.9 2 19.0 11.25 150 1.3 6 20.4 10.5 5.4 4 1.000 19.00 0.0 5 20.4 9.3 15.3 1.101 30.25 0.041 1.3 Pipe: 7 0.0 16.7 3 41.0 37.58 150 6.6 7 10.4 15.0 -5.4 5 1.000 41.00 4.8 4 21.4 8.3 11.4 1.101 78.58 0.024 1.9 Pipe: 8 0.0 15.3 5 18.0 30.38 150 4.4 7 10.4 15.0 -12.1 8 1.000 18.00 4.3 6 20.4 10.5 3.3 1.101 48.38 0.002 0.1 Pipe: 9 0.0 3.3 6 27.5 15.04 150 2.1 8 9.4 17.0 11.4 4 1.000 27.50 0.4 7 10.4 15.0 14.6 1.101 42.54 0.038 1.6 Pipe: 10 0.0 15.3 5 27.5 37.50 150 6.5 8 9.4 17.0 -3.3 7 1.000 27.50 4.8 6 20.4 10.5 12.1 1.101 65.00 0.027 1.7 Pipe: 11 0.0 12.1 6 7.0 0.71 150 0.9 W 9.4 17.9 14.6 7 1.000 7.00 0.0 8 9.4 17.0 26.7 1.101 7.71 0.116 0.9 Pipe: 12 0.0 0.0 8.00 150 3.7 F 3.0 21.6 26.7 8 1.000 0.00 2.8 W 9.4 17.9 26.7 1.101 8.00 0.116 0.9 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 , DATE: 5/28/2019 C:\HASS DATA\HASS\2019 CALCS\N19052 PAK RESIDENCE .SDF JOB'TITLE: N19052 PK RESIDENCE Pipe Tag K-fac Add Fl Add Fl To Fit: L C (Pt) Frm Node El (ft) PT (q) Node/ Nom ID Eq.Ln. F (Pe) To Node El (ft) PT Tot.(Q) Disch Act ID (ft.) T Pf/ft. (Pf) Pipe: 13 0.0 E 3.0 26.1 26.7 W F 3.0 21.6 26.7 Pipe: 14 0.0 0.0 D 0.0 29.3 26.7 F E 3.0 26.1 26.7 Pipe: 15 0.0 0.0 C 0.0 33.8 26.7 E D 0.0 29.3 26.7 Pipe: 16 0.0 B 0.0 42.3 26.7 D C 0.0 33.8 26.7 Pipe: 17 Source 0.0 A 0.0 47.2 26.7 C B 0.0 42.3 26.7 NOTES (HASS): Fixed Pressure Loss Device 4.5 psi, 26.7 gpm 1.000 0.998 1.500 1.610 10.00 150 0.00 10.00 0.187 250.00 150 0.00 250.00 0.018 Fixed Pressure Loss Device 8.5 psi, 26.7 gpm 1.000 T: 5.9 0.998 20.00 150 5.93 25.93 0.187 (1) Calculations were performed by the HASS 8.8 computer program in accordance with NFPA13 (2016) under license no. 50110271 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 (2) The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.016 gpm. (3) Total pressure at each node is used in balancing the system. Maximum water velocity is 10.9 ft/sec at pipe 14. (4) Items listed in bold print on the cover sheet are automatically transferred from the calculation report. (5) Available pressure at source node A under full flow conditions is 68.85 psi with a flow of 37.04 gpm. (6) PIPE FITTINGS TABLE HASS Pipe Table Name: standard.pip 3.2 1.3 1.9 4.5 0.0 4.5 4.8 0.0 4.8 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 . DATE: 5/28/2019 C:\HASS DATA\HASS\2019 CALCS\N19052 PAK RESIDENCE .SDF JOB'TITLE: N19052 PK RESIDENCE PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkV1v BfyVly GatV1v AlmChk DPV1v NPTee 0.998 1.57 3.92 1.57 3.92 4.71 0.78 7.84 1.57 3.92 PAGE: A MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkV1v BfyVly GatVly AlmChk DPV1v Tee 1.610 4.00 8.00 2.00 9.00 6.00 1.00 10.00 10.00 8.00 PAGE: F MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) F E T R K C G F45 Ell Tee RunT Kplg ChkV1v Gate 1.101 1.40 2.50 6.00 1.70 1.00 8.00 0.40 • %j eVWil 3'-l0" 6'-2" 6'-10 L RISER L% `TION /J,/%fie 401,9'"% %rel%////4/1/,%%%��// T-11 1/2" 9'-0" '-11 VOW 5'-5 1/2" 5'-7" / Le4 (\e-b)e,/ 'qd///////% f/ 111//1/ tsa%111/,',,1 I t LOWER FLOOR SPRINKLER PIPING PLAN 1/8" PERMISSIBLE BENDING DEFLECTIONS SDR 13.5 (73T) (ONE END RESTRAINED) PIPE SIZE inches LENGTH OF RUN (L) IN FEET 2' 5' T 10' 12 15' 17' 20' 3/4" 1.3" 7.8" 15.4" 31.3" 4 .1" 70.5" 90.6" 125.4" 1" 1.0" 6.3" 12.3" 25.0" 36.0" 56.3" 72.3" 57.3 100.1"' 79.3°- 9.3"1W' 11/4" 0.8" 5.0" 9.7" 19.8" 28.5" 44.6" 1W' 0.7" 4.3" 8.5" 17.3" 24.9" 39.0" 50.1" 69.3" 2" 0.6" 3.5" 6.8" 13.9" 20.0" 31.2" 40.0" 55.4" 21" 0.5" 2.9" 5.6" 11.4" 16.5" 25.8" 33.1" 45.8" 3" 0.4" 2.4" 4.6" 9.4" 13.5" 21.2" 27.2" 37.6" L2 D L feet BLAZEMASTER® PIPE DIMENSIONS SDR 13.5 (ASTM F442) INCHES (MILOMETERS) NOMINAL SIZE AVERAGE OD AVERAGE ID POUNDS/FT. 3/4" (20.0) 1.050 (26.7) .874 (22.2) .168 1" (25.0) 1.315 (33.4) 1.101 (28.0) .262 1%" (32.0) 1.660 (42.2) 1.394 (35.4) .418 11A" (40.0) 1.900 (48.3) 1.598 (40.6) .548 2" (50.0) 2.375 (60.3) 2.003 (50.9) .859 234" (65.0) 2.875 (73.0) 2.423 (61.5) 1.257 3" (80.0) 3.500 (88.9) 2.951 (75.0) 1.867 R-11 BAT MINIMUM SECURE INSULATION TO JOIST INSULATION TO SHEEIROCK LEVEL N CUT INSULATION TO PUSH DOWN BETWEEN JOIST ' 10' 12' 14' 16' 18' NOTES SECURE INSULATION TO JOIST R-11 BAT MINIMUM OFENJOBEN As (D-8")+8 ' D 30" As (D-203mm)+B s D 762mm WIRINGIA 6" ELECT NDUIT BY (1) MAIN FLOOR SPRINKLER PIPING PLAN SOFFIT FORMULA INSULATION DOWN TO SHEEIROCK LEVEL TENTING DETAIL A R-11 BAT MINIMUM TENTING DETAIL B 2" ATTIC JOIST INSULATION TO SHEETROCK LEVEL 2" ATTIC JOIST REVISIONS FLOOR INSILATION DAFFI-E VENTED CONTIMICUsS OY!_R 6' FASCIA CPVC DROP = 0.329 FIRE SPRINKLER CPVC DROP FIRE SPRINKLER 1"CPVC ADAPTER 1" CPVC 1" STEEL PIPE 1" STEEL PIPE 1" STEEL PIPE 1" BACKFLOW DEVICE AMES 1" COPPER ADAPTER Finish Floor - 1" GALV STEEL 90° REC_EVW) JUN 25 2019 PUGET SOUND FIRE FIRE PREVENTION DEPT ELECTRIC BELL WIRING AND CONDUIT AND INSTALLATION TO BE BY OTHERS CENTRAL RISER MANIFOLD W/: F4l DRAIN AND TEST 2 FLOW SWITCH 3 PRESSURE GAUGE SIGNS ON BODY DRAIN NORCO FIRE PROTECTION POINT OF CONNECTION DRAIN TO DISCHARGE OUTSIDE OF BUILDING 1" COPPER LINE RISER DETAIL scale 1/2"=1'-0" CURE TIMES WITH ONE STEP SOLVENT CEMENT 200 psi (MAXIMUM) TEST PRESSURE PIPE SIZE inches Ambient Temperature During Cure Period 60"F to 120"F 40'F to 59"F OT to 39'F 3/4" 45 min. 1.5 hr. 24 hr. 1" 45 min. 1.5 hr. 24 hr. 114" 1.5 hr. 16 hr. 120 hr. 134" 1.5 hr. 16 hr. 120 hr. 2" 8 hr. 36 hr. See Note 1 234" 8 hr. 72 hr. See Note 1 3" 8 hr. 72 hr. See Note 1 Note 1 For these sizes, the solvent cement can be applied at temperatures below 32'F, however, the sprinkler system temperature must be raised to a temperature of 32'F or above and allowed to cure per the above recommendations prior to pressure testing. ALLOWANCE FOR FRICTION LOSS IN CPVC FITTINGS (EXPRESSED IN EQUIVALENT FEET OF PIPE) FITTING PIPE DIAMETER 3/4" 1" 114" 11h" 2" 234" 3" TEE BRANCI- 3 5 6 8 10 12 15 TEE RUN 1 1 1 1 1 2 2 ELBOW 90° 7 7 8 9 11 12 13 ELBOW 45' 1 1 2 2 2 3 4 COUPLING 1 1 1 1 1 2 2 CURE TIMES WITH ONE STEP SOLVENT CEMENT 200 psi (MAXIMUM) TEST PRESSURE PIPE SIZE inches Ambient Temperature During Cure Period 60'F to 120"F 40'F to 59'F O'F to 39'F 3/4" 45 min. 1.5 hr. 24 hr. 1" 45 min. 1.5 hr. 24 hr. 11,4" 1.5 hr. 16 hr. 120 hr. 134" 1.5 hr. 16 hr. 120 hr. 2" 8 hr. 36 hr. See Note 1 234" 8 hr. 72 hr. See Note 1 3" 8 hr. 72 hr.. See Note 1 Note 1 For these sizes, the solvent cement can be applied at temperatures below 32"F. however, the sprinkler system temperature must be raised to a temperature of 32'F or above and allowed to cure per the above recommendations prior to pressure testing. GENERAL NOTES 1. System to be designed to N.F.P.A. #13D, 2007 edition and Fire Department requirements. 2. System hydraulically calculated to Fire Departments requirements and to N.F.P.A. 13D and Manufacturers Requirements. 3. Minimum pipe size to be 1" throughout job. 4. System to be hung per manufacturers requirements. Avcon Hangers to be used - Fig 511 & no block & head set. 5. All underground piping to conform to local Water Department requirements. This is for fill line only 6. Water information to be provided by pump manufacturer. Source of water by owner. 7. Transition from underground to riser to be copper type K typical unless noted otherwise 8. Risers that are exposed should be to be steel, cpvc is exceptable. Risers that rise up in wall to have typical access panel, provision of this panel to be per contract. 9. All electrical wiring and conduit for electrical switches to be by others. 10. Cleaning and painting of pipe to be by others, if required. 11. All drilling and notching to be per manufacturers specifications and Fire Department requirements. 12. All piping to be CPVC typical unless otherwise noted. 13. Items to be verified at time of inspection: a) Pressure at base of riser b) Sprinkler head location and spacing. c) Heads located from heat zones d) Exposed piping should be steel. e) Sprinkler heads in unconditioned areas to be 175° degrees 14. Alarm bells to be located per Fire Department requirements. 15. Testing of system to be per N.F.P.A. #13D and Fire Department Requirements. 16. Sprinklers may be omitted from closets less than 3'0" in depth or not over 24 sq. ft. TABLE 1 MAXIMUM SUPPORT SPACING DISTANCE END LINE SPRINKLER HEAD DROP ELBOW PIPE SIZE inches SYSTEM PRESSURE < 100 psi > 100 psi 3/4" 9" 6" 1" 12" 9" 134" 16" 12" 11/2"-3" 24" 12" TABLE 2 MAXIMUM SUPPORT SPACING DISTANCE INUNE SPRINKLER HEAD DROP TEE PIPE SIZE inches SYSTEM PRESSURE < 100 psi > 100 psi 3/4" 4' 3' 1" 5' 4' 134" 6' 5' 1W-3" 7' 7' TOT" OF MIME TTWJCAL PlOCIP CCIAISTRICTION ARC34. LAM. COMP. WOGPINe O've.R 13 P2061.246 PELT OVEwV2' ODX O T/I6' 0814 *ma (COX PLY= AT moven) EAVES) PFG. BOOP Time • 24' OA 2 -CAR GARAGE GOV'D DEGG 6 MIL /FLACK) V. SECURE AGAINST UPWARD MOVEMENT ••••%.4.1.14,..1.3 4\1 ♦ Z .•wavwsawer+aaes110V,r,trOott ..a.>.rw'...... ♦ ,wv ,, -ti.rf:,x>,yr r,s/ r rs.lNt'. -ea.✓,`n. r v.rr rs t •,te,.,♦ I�� r+caty\ !\I�\I\„Nas,{ V�\\.\��. N. n�\i�\�.: .. N. N`�i\��\!�\22.\i\If\`` xW1]. ✓.n.N S_ K/ ''+•N ��` . 2'-0 R-10 1812I0 1BUILDING SECTION A ----A FLOOR ASTM F442 CPVC BRANCHLIJE FLOOR CEILING FLOOR JOISTS FIRE SPRINKLER *NSF INTERNATIONAL APPROVED FOR USE WITH POTABLE WATER MAXIMUM SPACING OF HEADS TO BE 18 X 18 AND 9' OFF WALL IN SINGLE HEAD ROOM MAXIMUM SPACING OF HEADS TO BE 16 X 16 AND 8' OFF WALL IN MULTIPULE HEAD ROOM SPRINKLER SYMBOLS SYMBOLS ® SYSTEMS RISER o RISE UP • DROP DN 2 WAY EARTHQUAKE BRACE sf-, 4 WAY EARTHQUAKE BRACE GROOVED COUPLING \#01 HANGER TYPE AND LOCATIO Q UPRIGHT HEAD ® PENDENT HEAD f> SIDE WALL HEAD LEGEND 25 O6 UPRIGHT OVER PENDENT PIPE SIZING HYDRAULIC CALC NODE REVISION NUMBER El BRANCH LINE NUMBER WELD TAG NUMBER DATE DESCRIPTION BY SYM CNT NAME METAL TEMP K NPT I:1RIF MFG. MODEL# ESCUT CONN, tt 31 CONCEALED WHITE 160 4,9 1/2" 7/16 RELIABLE RC 49 (2.1) Defaut 7 4 DRY PEND WI-IITE 160 5,6 1' 1/2 RELIABLE F3QR (3.0) Defaut 35 TOTAL HEADS ON THIS PROJECT OUAIeD RAILS MUST BE AF51.E TO WITHSTAND A ATEA LOAD OP 2830 APPLIED AT RAIL NN ANY DIRECTION. PER TABLE It1 Le -11AttPt.00R 2x6 STUDS 16' OZ. B.' R-21 INSULATION TYP. F1N1814 PBW ELEVATION OVER I' ODX OR O.S.B. '2Y P/9.25.L 9 AVEltAtie GRADE • 224.2' TP - 234' - 232' -230' -226' - 226' 4 IGIVT2426 PERM VIER 61 trrts SECURE AGAINST ASTM CPVC UPWARD MOVEMENT BRANCHLILI E mmumwAsm momma,Tommin C EILIN FIRE SPRINKLER *NSF INTERNATIONAL APPROVED FOR USE WITH POTABLE WATER FLOOR JOISTS 0 STEEL PIPE 11111 BLAZEMASTEF! CPVC EMALE ADAPTER BACKFLOW ASSEMBLY REQUIRED IS PER STATE PLUMBING CODE NOT FIRE DEPARTMENT IS REQUIRED PARTOWATER THE POTABLE WATER SYSTEM PERMITING AND INSTALLATION AND TESTING TO BE DONE BY OTHERS ORCO Fire Protection, Inc. PO Box 363 Ravensdale, WA 98051 425-432-7250 - 224 - 222' -22®' AECON 511 C.P.V.C. PIPE HANGER SIDE MOUNT MATERIAL: CARBON STEEL APPROVALS: UL AND CUL LISTED. FINISH: MIT.. GALVANIZED, G-90 GOVERNMENT SPEC. C.I'.V.0 PIPE SIZE A B C MAX. HANGER SPACING (FT) 3/4" 311S" 19/16 13/16 51/2 i" 33.'8" 111:16 13;16 6 11/4" 43/16" 23/32 13/16 61/2 11r" 47116"27/32 (2.1) 13/16 7 „ 4 7/8" 2 7/16 1 3/16 8 BLAZEMASTER® PIPE SDR 13.5 (ASTM F442) HANGER SPACING NOMINAL SIZE MAX SPACING inches (mm) feet (m) 3/4" (20.0) 5.5' (1.7) 1" (25.0) 6.0' (1.8) 134" (32.0) 6.5' (2.0) 134" (40.0) 7.0' (2.1) 2" (50.0) 8.0' (2.4) 234" (65.0) 9.0' (2.7) 3" (80.0) 10.0' (3.0) • 4••• • -a OWNER INFORMATION NAME TUKWILA EDGE HOMES ADDRESS 10225 SE 24TH ST KENT, WASHINGTON 98031 PHONE 425-481-8827 FIRE DEPT INFORMATION NAME TUKWILA FIRE DEPT ADDRESS 444 ANDOVER PAARK EAST TUKWILA, WA 98188 PHONE 425-481-8827 WATER DEPT. INFORMATION NAME ADDRESS PHONE WATER INFORMATON STATIC 75 RESIDUAL 20 GPM 4856 MAIN SIZE 8" SOURCE AS BUILT DRAWING TUKWILLA WATER DEPT BUILDING INFORMATION SQ. FT. 5063 SQ.FT. TYPE Wood Frame OCCUPANCY Residential LEGAL DESCRIPTION TAX PARCEL ID# 334840-0949 4640 .S 1:48th ............-,St ......... VICINITY MAP r sr rRM►s1► Ir of do p e of o of o ok 6r rl ul llu nworova lit i dile ams, WA$N$NQTQ$ lrTA et/amp/ma OF C*MP; NCy * • t i4 (mutton spit/NM-EA MY$'1t* .. . $ I d11'arin P. C4sg11r 025.04,41K0 Novo Piro H SInGLE FAMILY RESIDEnCR S 114TH ST TUKWILLA, WA 98178 CONTRACTOR: NORCO FIRE PROTETION, INC. N OVE JUL 01 zms PUGET SOUND FIRE FIRE PRE1/ENTION 19-5-131 PAD TUK\ C e fer7 PIPING PLAN AREA 1 PERMIT NO. CONTRACT NO. N18061 APPROVAL TUKWILLA FIRE DRAWN BY ED COGAR SCALE 1/8" = 1'-0" DATE 7/14/18 REVISED PLOTTED FP1of1