Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PP - 10231 EAST MARGINAL WAY SOUTH - PRO USA LLC - PERMITS AND PLANS
10231 EAST MARGINAL WAY SOUTH ASSOCIATED PERMITS 01-F-213 tgco Fire & Security ADT LIST OF MATERIALS SUPPLIED TO: Pacific Rim Transportation 10231 East Marginal Way Seattle, WA 98168 FOR FIRE ALARM MONITORING BY: ADT SECURITY SYSTEMS CONTACT: Tony Puetz TELEPHONE: 206-389-6943 REGISTRATION NUMBER: ADTSES I03205 DATE: 9/7/01 QUANTITY MODEL DESCRIPTION ADT Security Services, Inc. 841 Powell Avenue, SW Suite 101 Renton, WA 98055-2910 Tele: 206 624 3 103 Fax: 206 654 2 189 1 472462EA Focus 200 Plus Package 2 432105 B3210-022 10" Bell (for indoor/outdoor use) 2 S24110 Strobe 110 candela 1 471210 Focus 200 Interactive Keypad 13 429CAD SIM Smoke Detector w/out Heat 3 472396 SIM Heat Detector 135° 6 472496 SIM Heat Detector 194° 4 472370 Manual Pull Station w/SIM NOTE: This is a new installation in a newly constructed double wide building. two IFire & Security Battery Calculation Worksheet (all currents stated in mA) 09/07/01 PROJECT: Pacific Rim Transportation, Seattle, WA Device Quantity of Standby mA Alarm mA Total Device Total Device Description Devices Per Device Per Device Standby mA Alarm mA System Devices 472462EA Focus 200 1 300 440 300 440 471210 Focus 200 Interactive Keypad 1 32 65 32 65 472496 SIM Heat Detector 194° 6 2 2 12 12 Total System Current 4 1 1 332 505 Smoke Detectors / Auxiliary Devices 429CAD SIM Smoke Detector w/out Heat 13 1 3 13 39 472396 SIM Heat Detector 135° 3 2 2 6 6 472496 SIM Heat Detector 194° 6 2 2 12 12 472370 Manual Pull Station w/ SIM 4 1 1 N/A 0 Device Totals 28 i 31 57 Notification Appliances (list all) 432105 10" Bell for indoor/outdoor use 2 N/A 30 N/A 60 S24110 Strobe 110 Candela 2 N/A 191 N/A 382 Min. A/H Battery 8.80 N/A 2.64 N/A 0 N/A N/A 0 Notification Appliance Totals 2 N/A 442 Summary Section Standby Hrs. Required 24 Alarm Sounding Minutes 5 Total System Standby mA 363 Total System Alarm mA 1004 Total System Standby A/H 8.71 Total System Alarm A/H 0.08 Min. A/H Battery 8.80 ADD 30% FOR BATTERY DEPLETION 2.64 Required A/H Battery 11.43 A/H BATTERY PROVIDED FOR SYSTEM 14 © 4 NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in $40 Re- inspection Fee and termination of the testing. 1) -VCOL 1,z13/zk,S ACCE'TED a Without Comments As Noted In Red Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current city Standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. 'jAdditions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: t (6(O 1 By 5(c=. TUKWILA FIRE OEPARTMEN1 Please call: 575-4407 and give this job and exact address for shut tdown or restoration approval. SSP 1 4_2,00401, 6'-0" 14'-4$" 03 \ \ � M • EOL 22'-0" 32'-38" 411 • D 38'-0" SIGNA FROM 6'-0" 12'-0" O EOL 18'-0" 22'— 4" 42'— 0" 30'-0" 36'-8" FROM CONTROL DETECTION PANEL CIRCUIT CIRCUIT CONTROL O co M co NORTH OFFICE PLAN SCALE: 1/4" = 1'-O" 64'— TWO LINES TO CENTRAL STATION TELCO LINE RJ31X CONN BLOCK T r r r r C 0T T T T r r r r r r r r r © © © © © © © © © © © © © RJ31X CONN BLOCK RISER DIAGRAM 3'-8„ 8'— 4" 12'-0" 22'— 0" 27'-5" 32'-1" 37'-6" 42'-9" 47'-11" 55' —10" EOL OFFICE #1 EOL ib 00 • 1 1 OFFICE #2 7'-0" F -1=r1 1 H N LO CON FEREf ROO C TO OFFIC1i= 0 U LC 3' — 8" 8'— 4" 17'-0" ANN 35'-0" OFFICE #3 411 0 I H OFFICE #5 2'-0" 0 EOL 1 P=Fi=r1 1 1 F—t1=i 1 26'— 0" 30'-8" I 1- =; 1 i F.--hi=r1 1 411 411 ea FOCUS 200P 0 OFFICE 1 P—#1=d 1 1 1-'—ht—d 1 4 I ; 1 1I H=.-11 35'— 4" 40'-0" 44'-0" 46'-6" NORTH FLOOR PLAN SCALE: 1/4" = 1 ' -0" 51'-2" 55'-10" 60'-6" l 120 VAC ANN--1v/`- LEGEND FACP ANN FIRE ALARM CONTROL/COMMUNICATOR PANEL HORN/STROBE, WALL MOUNTED STROBE BELL/STROBE MANUAL PULL SMOKE DETECTOR HEAT DEI ECTOR ANNUNCIATOR EOL END OF LINE r A ADT SECURITY SERVICES 841 POWELL AVE SW RENTON, WA 98055 (206) 624-3103 FAX: 654-2189 R M No. Revision/Issue Dote REPRESENTATIVE: TONY PUETZ CHECKED BY: CHECKED BY DATE: APPROVED BY: APPROVED BY DATE: Project Dots 09-10-01 Scots 1/4" = 1'-0» ADT -1Sheet