PP - 10315 EAST MARGINAL WAY SOUTH - ABC TOWING - PERMITS AND PLANS
10315 EAST MARGINAL WAY SOUTH ASSOCIATED PERMITS 19-F-078 01-F-098 JIMPILB SITE LOCATION CITY OF TUKWILA FIRE MARSHAL'S OFFICE 206-575-4407 FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** 4J \`yrL`_'r�) APR 0 4 2019 E r NFIRtoN DEpT King Co. Assessor's Tax No.: 0423049051 Site Address: 10315 E Marginal Way S Suite Number: Floor: all Tenant Name: ABC Towing New Tenant? ❑ - Yes E- No Property Owner's Name: ABC Towing Mailing Address: 10315 E Marginal Way S Tukwila WA 98168 City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Treyven Chin Day Telephone: 206-436-5300 Company Name: Washington Alarm Mailing Address. 2030 Airport Way S E-mail Address: permits@washingtonalarm.com City 5e4+He Fax Number: 206-322-7214 Contractor's City of Tukwila Business License number: BUS -0992857 State JA Zip 1134 Total number of new/relocated devices or sprinkler heads: 1 Valuation of Project (contractor's bid price): $ 900 Scope of Work (please provide detailed information): Installing AES radio next to Existing FACP PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: /Ark- /60 Print Name: Treyven Chin Plan Permit App.doc PAID Ap? -1 2319 Date: 4/1/2019 I UKIVILA ff R:. 206-436-5300 Day a ephone: 8/22/14 TFD FP Form 8 fico Fire & Security ADT LIST OF MATERIALS SUPPLIED T0: Annabells DBA Voyveur -10315 East Marginal Way Tukwila, WA 98168 FOR FIRE ALARM MONITORING BY: ADT SECURITY SYSTEMS CONTACT: Tony Puetz TELEPHONE: 206-389-6943 ADT Security Services, Inc. 841 Powell Avenue, SW Suite 101 Renton, WA 98055-2910 Tele: 206 624 3 103 Fax: 206 654 2 189 REGISTRATION NUMBER: ADTSES 103205 DATE: 08/08/01 QUANTITY MODEL DESCRIPTION r; FILE PO 1 472511 Focus 200 Fire Alarm Panel 1 Focus 200 Annunciator (Keypad) 1 432105 B3210-022 10" Bell (for indoor/outdoor use) 1 P121575 Horn/Strobe Red 12vdc 15/75cd 2 S121575 Strobe Red 12vdc 15/75cd 1 S1215 Strobe Red 12vdc 15cd 4 429CAD SIM Smoke Detector w/out Heat 2 472370 Manual Pull Station w/ SIM 1 472396 SIM Heat Detector 135° Fixed Temp& Rate of Rise NOTE: This is a resubmittal for a new installation in a newly constructed building. tqco I Fire & Security Battery Calculation Worksheet (all currents stated in mA) 08/08/01 PROJECT: Annabells dba Voyveur, Tukwila, WA Device Quantity of Standby mA Alarm mA Total Device Total Device Description Devices Per Device Per Device Standby mA Alarm mA System Devices Focus 200 Fire Alarm Control Panel 1 300 440 300 440 Focus 200 Annunciator (Keypad) 1 32 64 32 64 429CAD Sim Smoke Detector w/out Heat 4 3 1 12 4 Total System Current 2 N/A 157 332 504 Smoke Detectors / Auxiliary Devices 472370 Manual Fire Pull Station w/SIM 2 1 1 2 2 472396 SIM Heat Detector 1 2 2 2 2 429CAD Sim Smoke Detector w/out Heat 4 3 1 12 4 S1215 Strobe Red 12vdc 15cd 2 N/A 157 N/A 314 Device Totals 9 I 11.00 I 16 8 Notification Appliances (list all) 432105 B3210-022 10" Bell 1 N/A 30 N/A 30 S121575 Strobe Red 12vdc 15/75 Candela 2 N/A 171 N/A 342 P121575 Hom/Strobe Red 12vdc 15/75cd 1 N/A 181 N/A 181 S1215 Strobe Red 12vdc 15cd 2 N/A 157 N/A 314 Notification Appliance Totals 5 I 11.00 I N/A 837 Summary Section Standby Hrs. Required 24 Alarm Sounding Minutes 5 Total System Standby mA 348 Total System Alarm mA 1349 Total System Standby A/H 8.35 Total System Alarm A/H 0.11 Min. A/H Battery 8.46 ADD 30% FOR BATTERY DEPLETION 2.54 Required A/H Battery I 11.00 I A/H BATTERY PROVIDED FOR SYSTEM I 14 1 - tyco Fire & Security ADT ADT Security Services, Inc. 841 Powell Avenue, SW Suite 101 Renton, WA 98055-2910 Tele: 206 624 3 103 Fax: 206 654 2 189 LIST OF MATERIALS SUPPLIED TO: Annabells DBA Voyveur 10315 East Marginal Way Tukwila, WA 98168 FOR FIRE ALARM MONITORING BY: ADT SECURITY SYSTEMS CONTACT: Tony Puetz TELEPHONE: 206-389-6943 REGISTRATION NUMBER: ADTSES I032O5 DATE: 04/12/01 QUANTITY MODEL DESCRIPTION 1 472511 Focus 200 Fire Alarm Panel 1 Focus 200 Annunciator (Keypad) 1 432105 B3210-022 10" Bell (for indoor/outdoor use) 1 P121575 Horn/Strobe Red 12vdc 15/75cd 1 S121575 Strobe Red 12vdc 15/75cd 1 S1215 Strobe Red 12vdc 15cd 4 429CAD SIM Smoke Detector w/out Heat 2 472370 Manual Pull Station w/ SIM 1 472396 SIM Heat Detector 135° Fixed Temp& Rate of Rise NOTE: This is a new installation in a newly constructed building. tgcQ I Fire & Security Battery Calculation Worksheet (all currents stated in mA) 04/12/01 PROJECT: Annabells dba Voyveur Device Quantity of Standby mA Alarm mA Total Device Total Device Description Devices Per Device Per Device Standby mA Alarm mA System Devices Focus 200 Fire Alarm Control Panel 1 300 440 300 440 Focus 200 Annunciator (Keypad) 1 32 64 32 64 429CAD Sim Smoke Detector w/out Heat 4 3 1 12 4 Total System Current 2 N/A 157 332 504 Smoke Detectors / Auxiliary Devices 472370 Manual Fire Pull Station w/SIM 2 1 1 2 2 472396 SIM Heat Detector 1 2 2 2 2 429CAD Sim Smoke Detector w/out Heat 4 3 1 12 4 S1215 Strobe Red 12vdc 15cd 2 N/A 157 N/A 314 Device Totals 9 16 8 Notification Appliances (list all) 432105 B3210-022 10" Bell 1 N/A 30 N/A 30 S121575 Strobe Red 12vdc 15/75 Candela 1 N/A 171 N/A 171 P121575 Horn/Strobe Red 12vdc 15/75cd 1 N/A 181 N/A 181 S1215 Strobe Red 12vdc 15cd 2 N/A 157 N/A 314 Notification Appliance Totals 4 N/A 666 Summary Section Standby Hrs. Required 24 Alarm Sounding Minutes 5 Total System Standby mA 348 Total System Alarm mA 1178 Total System Standby A/H 8.35 Total System Alarm A/H 0.10 Min. A/H Battery 8.45 ADD 30% FOR BATTERY DEPLETION 2.54 Required A/H Battery 10.99 A/H BATTERY PROVIDED FOR SYSTEM 1 14 Aug 08, 2001 - 1:19pm G:\ADTIA . N MITI MW SECURITY SERVICES 841 POWELL AVE SW RENTON, WA 98055 (206) 624-3103 FAX: 654-2189 LJA R IVI I I _LS DBA VO \ST MARGIN) 1 A AIAXnc No. Revision/Issue Date RESTROOM 0 0 EOL 11 EOL EOL TO CENTRAL STATION LEGEND cul CONTROL UNIT I= ANNUNCIATOR • MANUAL PULL a HORN STROBE • STROBE CO BELL ® SMOKE DETECTOR • HEAT DETECTOR TELCO UNE RJ38X CONN BLOCK SCAN ALERT ANN 1-AAN-- F0 C U S 200 120 VAC RISER DIAGRAM 3 0 0 0 3 REPRESENTATIVE: TONY PUETZ CHECKED BY: CHECKED BY DATE: APPROVED BY: APPROVED BY DATE [Project Date Seale RESUBMITTAL 08-10-01 AS NOTED Sheet ADT_1 ST FACP AES R v L BBY AES RADI❑ TO BE INSTALLED NEXT TO EXISTING FACP ALARV T0U3LE SUPRVISO AES AES-7707-P-88-ULP COMM UNI CA TOR nH BATTERY `A04 TAC3 VISTA 128 0 n H con nH 1/ f.3n BATTERY BATTERY 120 VAC (DEDICATED CST.) FRE A_A NOTE ALL SYMBOLS V SYM3OL LEGEND WAY NOT EE USED ON TEAS PROJECT SYMBOL DESCRIPTION MOUNTING FIRE ALARM CONTROL PANEL WALL -TOP @ 66" FACP AES FIRE ALARM RADIO FIELD VERIFY AES FIRE SYSTEM ANNUNCIATOR FIELD VERIFY FSA QZ SMOKE DETECTOR CEILING Ql HEAT DETECTOR CEILING MANUAL PULL STATION WALL @ 48" P (0) CEILING MOUNT STROBE FIELD VERIFY (Q) CEILING MOUNT HORN / STROBE FIELD VERIFY HORN WALL @ 10'-0 HORN / STROBE WALL 80"-96" X 1 STROBE WALL 80"-96" X ABBREVIATION DESCRIPTION SPEAKER IS 1111 75'rCAANDELA�30/�, E EXISTING ��w) l2 / G WITH GUARD P PENDANT MOUNT OZ ,r DEVICE ADDRESS O L1D001 OR DO1 — DENOTES LO (D or M —DENOTES DETECTOOPR 0) MODULE #) R REPLACE S SOUNDER BASE WP WEATHER PROOF(L EOL END OF LINE RESISTOR EOLR END OF LINE RELAY 1-#16/2 TWP ��- WIRE TYPE ABBREVIATED COUNT AWG AMERICAN WIRE GAUGE TWP TWISTED PAIR TWSP TWISTED SHIELDED PAIR FPLP FIRE POWER LIMITED PLENUM WIRE SIZER FPLR FIRE POWER LIMITED RISER # OF CABLES (IF OMITTED ONLY 1 CABLE NEEDED) NAC NOTIFICATION APPLIANCE CIRCUIT SLC SIGNALING LINE CIRCUIT GENERAL NOTES: 1. SCOPE OF WORK: INSTALLING AES RADI❑ TO EXISTING VISTA PANEL. 2, UNLESS OTHERWISE SPECIFIED, #14/2 AWG WIRE WILL BE USED FOR THE NOTIFICATION CIRCUIT. #16/2 AWG WILL BE USED FOR THE SIGNALING LINE CIRCUIT (SLC). 3. THESE DRAWINGS ARE DIAGRAMMATIC. REFER TO THE ARCHITECTURAL DRAWINGS FOR EXACT DIMENSI❑NS. 4. INSTALLATI❑N SHALL COMPLY WITH NEC, NFPA 72, AND ALL OTHER APPLICABLE CODES AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION. 5. WIRING DEPICTED ON THESE PLANS IS SCHEMATIC — ACTUAL WIRE LOCATI❑NS MAY DIFFER FROM THESE PLANS. WIRING SHALL BE PERFORMED AS ACTUAL BUILDING C❑NSTRUCTI❑N C❑NDITI❑NS ALLOW AND TO MINIMIZE PENETRATI❑NS THROUGH AREA SEPARATI❑N WALLS AND FIRE WALLS. THE USE OF A RACEWAY IS PERMITTED AS LONG AS NO 110V OR HIGHER VOLTAGE CABLES ARE IN THE SAME RACEWAY. 6. FIRE RATINGS SHALL BE MAINTAINED FOR ALL PENETRATI❑NS THROUGH FIRE—RATED C❑NSTRUCTI❑N. 7 POWER FOR ALL FIRE ALARM PANELS AND FIRE. ALARM POWER SUPPLIES MUST BE PROVIDED BY A DEDICATI❑N AC BRANCH CIRCUIT. THE L❑CATI❑N OF THE BRANCH CIRCUIT BREAKER SHALL BE PERMANENTLY IDENTIFIED AT THE CONTROL UNIT AND SHALL HAVE A RED MARKING IN ACCORDANCE WITH NFPA 72. 8. POWER—LIMITED AND N❑NP❑WER—LIMITED CIRCUIT WIRING MUST REMAIN SEPARATED IN CABINET. ALL POWER—LIMITED CIRCUIT WIRING MUST REMAIN AT LEAST 0.25" AWAY FROM ANY NONPOWER—LIMITED CIRCUIT WIRING, FURTHERMORE, ALL POWER—LIMITED AND N❑NP❑WER—LIMITED CIRCUIT WIRING MUST ENTER AND EXIT THE CABINET THROUGH DIFFERENT KNOCK OUTS AND/OR SEPARATE CONDUITS. 9, WHEN UTILIZING CLASS "A" CIRCUITS, SEPARATE OUTGOING AND RETURN CONDUCTORS OF CLASS "A" CIRCUITS BY A MINIMUM OF 12 WHERE RUN VERTICALLY AND 48:" WHERE RUN H❑RIZ❑NTALLY. 10. WHEN UTILIZING SHIELDED CABLE TIE SHIELDS THROUGH AND INSULATE AT EACH JUNCTI❑N B❑X, INSULATE AND TAPE BACK AT END. 11. ALL FIRE ALARM CABLING SHALL BE ACCEPTABLE TO THE FIRE ALARM EQUIPMENT MANUFACTURER FOR THE INTENDED PURPOSE. 12. SMOKE DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER CONSTRUCTION CLEAN—UP IS COMPLETED AND FINAL. 13. LOCATE SMOKE DETECTORS A MINIMUM OF THREE (3) FEET FROM MECHANICAL DIFFUSERS, WALL—MOUNTED SMOKE DETECTORS SHALL BE LOCATED A MINIMUM OF 4" AND A MAXIMUM OF 12" FROM CEILING. 14. PR❑VIDE SYNCHRONIZATION OF ALL VISUAL N❑TIFICATI❑N APPLIANCE CIRCUITS, PR❑VIDE ALL REQUIRED SYNC MODULES, PR❑VIDE A MULTI—SYNC MODE SLAVE CONNECTION BETWEEN ALL SYNC MODULES. 15, VERIFY ALL FIELD SELECTABLE AUDIBILITY SETTINGS OF NOTIFICATION APPLIANCES WITH FIRE ALARM CONTRACTOR. 16. UPON C❑MPLETI❑N OF THE FIRE ALARM SYSTEM INSTALLATI❑N AND PROGRAMMING, THE INSTALLING CONTRACTOR SHALL PERFORM FINAL TESTING OF THE ENTIRE SYSTEM, PER ALL APPLICABLE C❑DES, AND SHALL COORDINATE AND PERFORM A FINAL FIRE ALARM SYSTEM INSPECTI❑N. 17. PR❑VIDE ❑FF—SITE M❑NIT❑RING AS REQUIRED BY THE INTERNATIONAL FIRE CODE, SECTI❑N 907.6.5 AND THE LOCAL AUTHORITY HAVING JURISDICTI❑N. 18. INSTALLING CONTRACTOR SHALL, PHYSICALLY, LABEL ALL INITIATING DEVICES AND N❑TIFICATI❑N APPLIANCE CIRCUIT END OF LINE (WHEN WIRING CLASS "B"). THESE LABELS SHALL BE IN PLACE PRIOR TO START—UP AND TESTING. NOLLNEA Hd IJ E1:11.1 ciNnos 610Z I I 8ddPv/7 14 $�r UKVVILA FIRE DEPARTMENT Please call 206-575-4407 and give this Fire Permit No. /61-F-072 and exact address icor shut- down hutdown or restoration approval. PAID AQ? -12019 TUKWILA FIRE REC qWED APR 04 20191 PUGET SOUND FIRE FIRE PREVENTION DEPT /Phong Nguyen Cert. No. 139398 Exp. 01/01/2021 Fire Alarm Systems w 1— a DESCRIPTION z w CO CO C\2 c+� CO C\t C\2 � Q 7 KST A LLQTDON 0 a DRAWN CHECKED DATE REVISION SCALE TREYVEN CHIN JOIN 19052-1 PHEING NGUYEN NICET III 4/1/2019 1 1/8' = 1'-0' FA- RE ROO 1,1 CI CONTROL UNIT ® ANNUNCIATOR © MANUAL PULL a HORN STROBE ® STROBE CO BELL 0 SMOKE DETECTOR 0 HEAT DETECTOR Without Comments As Noted in Red Per The Attached Letter These plans have been .reviewed by The Tukwila Fire Prevention Bureau for conformance with current city standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. ©al acceptance is subject to field test and inspection by The Tukwila Fire Prevention : ureau. Date: A:\2.6 )1 By: EOL EOL. NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented tothe Inspector prior to commencemeht of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in $40 Re - Inspection Fee and termination of the testing. TUKWILA FIRE DEPARTMENT Please call: 575-4407 and give this job and exact address for shut down or restoration approval. 7Fr; ci ' t?PR 6 AM ADT SECURITY SERVICES 841 POWELL AVE SW RENTON, WA 98055 (206) 624-3103 FAX: 654-2189 HLHRIVI J I J I _LS DBA VO \ST MARGIN) 1 A 1A/ A QC No. Revision/Issue Dote 7Fr; ci ' t?PR 6 AM