12924 EAST MARGINAL WAY SOUTH ASSOCIATED PERMITS 96-F-028 GENE AL SalSTE v1 N•TICS I) FIRE ALARM SYSTEM IS POWER LIMITED. METALLIC RACEWAY SHALL BE USED IF REQUIRED BY CODE. SPECIFICATIONS AND CONTRACT DOCUMENTS OR AHJ. 2) ALL RACEWAYS MUST BE FREE OF MOISTURE 3) REFER TO SIMPLEX FIRE ALARM DATASHEETS FOR PROPER TYPE AND SIZES OF REQUIRED DEVICE MOUNTING ELECTRICAL BOXES. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR PROPER INSTALLATION OF ALL DEVICES. 4) AC VOLTAGE IS NOT PERMITTED IN THE SAME RACEWAY AS FIRE ALARM WIRING. 5) UNRELATED (NON -FIRE ALARM) WIRING SHALL NOT BE IN THE SAME RACEWAY AS FIRE ALARM WIRING. 6) ALL CONTACTOR FIELD WIRING MUST ENTER TOP RIGHT AND/OR BOTTOM RIGHT OF FIRE ALARM CONTROL PANEL ONLY. 7) ZONE CIRCUITS AND SIGNAL CIRCUITS ARE ELECTRICALLY SUPERVISED. BRANCH CIRCUITS SHALL BE LOOPED TO MAINTAIN INTEGRITY OF SUPERVISED CIRCUITS--T-TAPPING OF ZONE CIRCUITS AND SIGNAL CIRCUITS IS NOT PERMITTED. 8) REFER TO FACP MODULE DIAGRAMS, INCLUDED WITH FACP, FOR SPECIFICATIONS AND INFORMATION ON INDIVIDUAL PANEL MODULES. VERIFY ALL CONNECTIONS WITH A SIMPLEX FIELD TECHNICAL REPRESENTATIVE PRIOR TO TERMINATION. 9) ALL FIRE ALARM WIRING SHALL TEST FREE OF OPENS, SHORTS AND GROUNDS. 10) ALL WIRING SHALL BE LABELED AND TAGGED II) ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR INSTALLATION AND MAKING ALL FINAL CONNECTIONS PRIOR TO JOB CHECKOUT AND FINAL TESTING BY A SIMPLEX FIELD TECHNICAL REPRESENTATIVE. CALL A MINIMUM OF 5 DAYS IN ADVANCE TO SCHEDULE A SIMPLEX TECHNICIAN AT 632-4424. 12) ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR MAKING ALL ARRANGEMENTS FOR INSPECTION, TEST AND CERTIFICATION OF THE FIRE ALARM SYSTEM BY ALL APPROPIATE AUTHORITIES. 13) UPON WRITTEN REQUEST, SIMPLEX WILL PROVIDE WRITTEN INSTRUCTIONS REGARDING THE APPROPRIATE WIRE/CABLE FOR INSTALLATION OF THE EQUIPMENT/SYSTEM(S) IDENTIFIED IN THESE DRAWINGS. SIMPLEX SHALL NOT BE RESPONSIBLE FOR PROBLEMS OR DAMAGES RESULTING FROM THE USE OF WIRE/CABLE OTHER THAN THAT WHICH HAS BEEN INDENTIFIED IN WRITING BY SIMPLEX FOR A SPECIFIC APPLICATION. 14) ALL WIRING SHALL MEET ALL APPLICABLE NATIONAL ELECTRIC CODE ARTICLES FOR FIRE ALARM AND LOW VOLTAGE WIRING. ARCHITECT: FIRE ALARM SYSTEM DESIGNED BY: SIMPLEX TIME RECORDER CO. SEATTLE, WA FIRE ALARM SYSTEM INSTALLATION BY: •EQUIPMENT FOR FIRE ALARM SYSTEM BY: SIMPLEX TIME RECORDER CO. SEATTLE. WA o THESE DRAWINGS DO NOT SUPERCEED THE CONTRACT DRAWING$ AND SPECIFICATIONS, THEY ARE INTENDED AS A SUPPLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATIONS TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA. ©1994 Simplex Time Recorder Co. Gardner. MA. 01441 AD\ • UP f E-13 0 \-E:=A`A I I ji ii CONNECT TO 120 VAC 60 Hz (FUSED SOURCE) PANEL DRAWS 1.2 A 201 XMFR TYPICAL MINI-HORN/5TROBE l"lIRING DIAGRAM C=2 #14 AWG MINI-HORN/STROBE TYPICAL MINI-HORN/STROBE {MIRING DIAGRAM,, MINI-HORN/STROBE C=2 #14 AWG TYPICAL MANUAL PULL STATION A=2 #I6 AWG HIRING DIAGRAM A=2 #16 AWG 0 0 C=2 #14 AWG TO NEXT DEVICE OR I0K OHM ECC RESISTOR C=2 #I4 AWG TYPICAL MANUAL PULL STATION TYPICAL SMOKE DETECTOR HIRING DIAGRAM HIRING DIAGRAM 7--A=2 #I6 AWG A=2 #I6 AWG 4001 FIRE ALARM CONTROL PANEL POINT TO POINT HILINC DIAGRAM SCALL°t:NV*E ZONE SCHEDULE 1) BASEMENT 2) 1ST FLOOR 3) 2ND FLOOR 4) SPARE 02 BD-.. 0 ,-A 0 AD DN AD 0 UP e 0 T / TO DIALER l = UKcovcr-cdregs AUXILARY CONTACTS 1) ALARM - DIALER 2) SPARE 51 L3 S2 L2 L4 LI ACCEPTE ❑ WITHOUT COMMENTS. LAS NOTED IN RED PER THE ATTACHED LETTER The drawings affixed hereto have been reviewed and accepted by the City of Tukwila Fire Dept. Additions, deletions or revisions to thes1 drawings after this date will void this acceptance and will require a resubmittal of revised drawings. Final acceptance is subject to field - inspection by a representative of this department DATE: _ AS BY: 4-h'i CITY OF TUKWILA 575.4407 A=2 #I6 AWG TUKWILA FIRE DEPARTMENTL Please. calla 575'4407 and give this job No. n- F- Oa. and exact address for shut. down or restoration approval; TO NEXT DEVICE OR 3.3K OHM E01. RESISTOR 0 64a4Q /,off /�,�-c A i u -s. -� ,.- �.. ,�.� - /2,, <41A,64a9 la% u Q'`- J ,ti.F1--4,Za.R-4 �%-,,,,,r,�.r•,, ,?,,, Z , r".e1.4),c .,54---e-e.fi '-v d.e- d.zsu- 3F l ...,A,ag-tf2� A 4 i - 3 -9-,r SIGNAL CIRCUITS VOLTAGE DROP 1) HORN/STROBES VD= 0.644 AC AC • DN 4B0x nom( AC AC Th • 03 B-1/4 may....-.' AC 3I SEQUENCE' OF OPERATION MANUAL PULL STATION SMOKE DETECTION SYSTEM TROUBLE ACTIVATION OF LOCAL ALARM AT FACP (ZONE LED & AUDIBLE IIOICATION) N„, X BLACK/ORANGE TFN ACTIVATE ALL AUDIBLE & VISIBLE DEVICES X x 4 I TRANSMIT ALARM SIGNAL TO CENTRAL STATION MONITOR X X C TROUBLE INDICATION AT FACP RED/BLUE THHN _ x TRANSMIT TROUBLE SIGNAL TO CENTRAL STATION MONITOR ' RED/BLUE THHN X 2ND FLOOR IST FLOOR BASEMENT A SYMBOL DESCRIPTION LEGEND MODEL # BACK BOX MANUAL PULL STATION 2 . SUBSCRIPT INDICATES ZONE MINI HORN/STROBE 15/75cd 2 . SUBSCRIPT INDICATES CIRCUIT PHOTOELECTRIC SMOKE DETECTOR • SUBSCRIPT INDICATES ZONE 0 FACP FIRE ALARM CONTROL PANEL 02 2099-9754 4903-9224 2098-9201 W/ 2098-9211 BASE EXISTING 4" SQ W/SG BY EC SG BY EC 4" OCT BY EC EXISTING WIRE CODE ALL WIRING TO MEET CURRENT NATIONAL ELECTRIC CODE ARTICLE 760. 300. 310. 370, 725 AND ALL RELATED SECTION CODE REQUIREMENTS LETTER QTY COLOR/TYPE SIZE FUNCTION A 2 BLACK/ORANGE TFN 16 ZONE B 4 I BLACK/ORANGE TFN 16 ZONE LOOP C 2 RED/BLUE THHN 14 HORN/STROBE D ' RED/BLUE THHN 14 HORN/STROBE LOOP T 2 PURPLE/YELLOW THHN 14 DIALER NOTES: 1) TAG AND IDENTIFY ALL ZONE WIRES WITH ZONE NUMBER. 2) TAG AND IDENTIFY ALL SIGNAL CIRCUIT WIRES WITH SIGNAL CIRCUIT NUMBER. 3) TAG AND IDENTIFY ALL ANNUNCIATOR WIRES. NOTES: 1) FIRE ALARM DRAWINGS ARE SCHEMATIC ONLY, 2) 4001 FACP IS EXISTING. BATTERY Y CA'LCU ATO ;NS DOES THE SYSTEM HAVE AN EMLRGENCY GENERATOR THAT MEETS NEC 700.701 0 YESII NO? HON MANY HOURS OF BATTERY 'STANDBY ARE REQUIRED? ❑ 4 11 24 0 48 0 60 (4 HRS. MIN. W/Et.1ER. GEN.) kf. QTY PART / DESCRIPTION STANDBY TOTAL ALARM TOTAL CURRENT (A) STANDBY (A) CURRENT (A) ALARM (A) 4001-8001 15 2098-9201 7 4903-9224 FIRE ALARM CONTROL PANEL PHOTOELECTRIC SMOKE DETECTOR MINI-HORN/STROBE 15/75cd 0.0620 0.0001 0.0000 0.0620 0.0015 0.0000 Total Standby- 0.0635 Total Standby Current Required- 0.0635 Total Alarm Current Required= 1.9090 Total - 20% Depletion Factor Total Amp/Hour Required Total Amp/Hour Batteries Provided 0.3640 0.0470 0.1200 Total Alarm - Time (Hrs.) X 24.0000 X 0.0830 (1) Set 0.3640 0.7050 0.8400 1.9090 1.5240 0.1584 1.6824 0.3365 2.0189 10.0000 A A C C v - 0 - 0 - 04 ©4 EOL F EOL EOL I20VAC - AC 0 4001 FACP EOL I mi -TO DIALER D \-- c AD EARTH GARTHDTED ©4 D RISER DIAGRAM SCALE: NONE HORN/STROBES HORN/STROBES HORN/STROBES #05159 2. 5 3 I X 0 SIMPLEX TIME RECORDER CO. 455 NORTH 35TH ST SSEA ESTL 632-4451 1 WA. 98103 SERVICE 632-4424 FIRE ALARM SYSTEM WILLIAM SCHMIDT 12924 EAST MARGINAL WAY SOUTH TUKWILA. WA ISSUE RECORD PURPOSE DATE Q DESIGN CHANGE 1-22-96 DRAWN BY: SAL DATE: 9-14-95 APPROVED BY: S.R.B. SHEET TITLE: WIL-SCH SHEET NUMBER: 1 OF 1