HomeMy WebLinkAboutPP - 337 STRANDER BLVD - L BEAUTY BAR - PERMITS AND PLANS337 STRANDER BLVD
ASSOCIATED PERMITS
13-F-225
05-F-231
13-S-207
91-173
91-168
900341
900309
SITE LOCATION
37
CITY OF TUKWILA
FIRE DEPARTMENT
444 Andover Park East
Tukwila, WA 98188
206-575-4407
Date application
accepted:
FIRE PROTECTION SYSTEMS PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
**PLEASE PRINT**
King Co. Assessor's Tax No.:
Site Address: -- ‘-571ZA/1ibei2 3L ✓•D Suite Number: Floor:
• ,
Tenant Name: L AEM.JD1 BA,Q
New Tenant? [ Yes ❑ - No
Property Owner's Name: jQEL7EAIC t/ CEArTr
Mailing Address:
City
CONTACT PERSON -if there are questions about the submittal.
Name: AAto&I ?ZTTEfz
State Zip
Day Telephone: 04.0 772--792-
Company Name: ,.ID'¢-TEabl EST dFIRE SkiSTEk
It
Mailing Address: 7fis s. 107/4 ST. Karr, WA y 9 Z_
City State Zip
E-mail Address: APD-TJLe_ Jkir/ QE.SyS rehnt • LD'In& Fax Number: (24-1rj /it -7%4-
Total number of new/relocated devices or sprinkler heads:
Valuation of Project (contractor's bid price): $ // I DD
Scope of Work (please provide detailed information): (GLOLATIo# I { A t i, no w1 QF `IRE Vg -ha Las
P.2 j) _ CoVeLd4E 7)t6 1 AJeetupiy f»SFl4ua,A1ro*1.
PERMIT APPLICATION NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules.
Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit
is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or
abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in
writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE
UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY
FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Signature:
Print Name: A P rLDk cy.c— el _
Date:
Day Telephone: €2,9 V) 'Tit- 7 sbL
Plan Permit App.doc 1/2/13 TFD FP Form 8
SITE LOCATION
CITY OF TUKWILA
FIRE DEPARTMENT
444 Andover Park East
Tukwila, WA 98188
206-575-4407
Date application
accepted:
FIRE PROTECTION SYSTEMS PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
**PLEASE PRINT**
,[ / King Co. Assessor's Tax No.:
Site Address: 6ead�y /ga 1' Suite Number: Floor:
Scrv��i Ce of c r f%2... e331 %�`t/� kt, NATenant Name: New Tenant? ❑ - Yes [No
Property Owner's Name:
Mailing Address:
City State Zip
CONTACT PERSON -if there are questions about the submittal.
Name: /�i 0/ec/i r C SeY1i 7 ce Day Telephone:
Company Name:
YDvMg DJ
Mailing Address: 3.2-5.(/9 3 >rd A VC --
"&t,41 every w.4 Tic t 3
City State Zip
E-mail Address: /t U /bye ( V " I1 � ` f O''r Fax Number:
Total number of new/relocated devices or sprinkler heads:
/0.
Valuation of Project (contractor's bid price): $ / c49e, '
Scope of Work (please provide detailed information):
J
.7A4Atlitv kre 4,5
PERMIT APPLICATION NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be
reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules.
Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit
is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or
abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in
writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE
UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY
FOR THIS PERMIT.
BUILDING OWNER `dTlr.RIZED A NT:
Signature:
Print Name: 4/
Date: 9"-R
Day Telephone:
Plan Permit App.doc 1/2/13 TFD FP Form 8
FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS
Project Name: "L" Beauty Bar
337 Strander BI
Permit No.: 13-S-207
Date: September 16, 2013
Reviewer: Al Metzler
Fire Protection Project Coordinator
(206) 575-4407 option # 2 (Inspection Requests)
(206) 971-8718 (Plan Review Questions)
• Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross
mains, and branch lines 2.5" and larger. Bracing is provided for the last length of
pipe but within 6' of the end of a feed or cross main. Bracing is required unless
all the pipe is supported by rods less than 6" or by 30 ° wrap-around U -hooks for
any size pipe, 9.3.5.3.
• Minimum clearance around pipes: 2 " for 1"-3.5", 4" for 4" and larger, see 4
exceptions, 9.3.4.
• Longitudinal sway bracing is a maximum of 80' for mains and cross mains and
within 40 ' of the end of the line, 9.3.5.4.
• Provide lateral and longitudinal bracing for changes in pipe direction per section
9.3.5.11.2 for pipe size 2 1/2 inches and larger.
• Restrain branch lines at the end sprinkler of each line, restrain against vertical
and lateral movement, 9.3.6.3.
• Restraints for branch lines shall be at intervals per table 9.3.6.4 and section
9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6.
• Comply with ASCE 7-02, section 9.6.2.6.2 (e).
• Ceilings used for flex drop attachments shall comply with ASTM C 635 and
ASTM C 636 per section 9.2.1.3.3.2.
• Where flexible sprinkler hose fittings exceed 6ft. in length and are supported by a
suspended ceiling, a hanger(s) attached to the structure shall be required to
ensure that the maximum unsupported length does not exceed 6 ft.(9.2.1.3.3.3).
• Provide sprinkler protection beneath all obstructions greater than 4 ft. in width.
• Extend sprinkler protection to all combustible concealed spaces.
• Comply with NFPA 13 obstruction tables.
• Comply with obstructed/non-obstructed construction rules for sprinkler head
placement.
• Sprinkler heads spaced closer than 6 ft. apart must be baffled.
• Modifications involving 20 or more sprinkler heads require hydrostatic test and
system isolation if necessary.
• For dry pipe and double interlock preaction systems in addition to the standard
hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24
hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the
24 hours shall be corrected.
All code references are NFPA 13, 2010 Edition.
Device Description
SK5495(existing)
Unused
Unused
Battery Calculation Worksheet
(all currents stated n mA)
mA Draw each Total mA Draw
# of Devices Stand By Alarm Stand By Alarm
System Devices
160
0
0
330
n
n
160
o
o
330
�
o
Total System Current 1
160 330
WATER
TEMPER(EXISTING)
EXISTING SMOKE AT FACP
2WBT SMOKE
Initiation Devices / AuxiaDevices
: 0.05
-. •• .��*
170.05
0.05
0.05
o
o
n
o
0.05
0.1
0.050.85
o
o
n
o
Device Totals � Z11:1�`
1.05
SR STROB c15CD(EXISTING AND NEW)
P2R HORN/ STROB@75 CD(EXISTING AND NEW
Unused
Unused
Unused
Unused
Unused
Notification Appliances (Iist all)
Circuit 1
0
79
79
0
0
0
0
0
158
553
0
0
0
0
0
Circuit 1 Totals. 9
0 711
EXISTING BELL FOR OUTSIDE(EXISTING)
EXISTING HORN srnoas@7eoosu/Tsmo(sxmr/mm)
Unused
Unused
Unused
Unused
Unused
EXISTING PC2R
Unused
Unused
Unused
Unused
Unused
Unused
176
176
0
0
0
0
0
176
0
0
0
0
0
0
176
1056
0
0
0
0
0
1056
0
0
0
0
0
0
Circuit 3 Totals
Unused
Unused
Unused
Unused
Unused
Unused
Unused
Circuit *Totals o
Notification Appliances Totl Curren22
0 2999
Design Voltage
24
Voltage Drop Calculation Worksheet
Circuit #1
Length Amp Draw Wire Guage Loss per 100' Voltage Drop Voltage at EOL Voltage Drop %
250 0.711 14 0.36 0.90 23.10 3.73%
Circuit #2
Length Amp Draw Wire Guage Loss per 100' Voltage Drop Voltage at EOL Voltage Drop %
250 1.232 14 0.62 1.55 22.45 6.47%
Circuit #3
Length Amp Draw Wire Guage Loss per 100' Voltage Drop Voltage at EOL Voltage Drop %
250 1 056 14 0.53
1.33 22 67 5.55%
Circuit #4
Length Amp Draw Wire Guage Loss per 100' Voltage Drop Voltage at EOL Voltage Drop %
250 0 14 0.00 0.00 24.00 0.00%
Standby Hrs.
Alarm Sounding Minutes
Total System Standby mA
Total System Alarm mA
Total System Standby Ah
Total System Alarm Ah
Min. Ah Battery
Derating Factor
Battery Ah
Battery Used
Summary Section
Required
48
5
161.05
3329
7.730
0.277
8.008
20%
10.010
Available
::
C.ubb
Security Services
RE: South Center Plaza
Go Verizon
337 Strander BLVD
Tukwila, WA
Tukwila Fire Marshal,
150 12`h Ave. Seattle, Washington 98122
206.624.1115 Fax 206.621.8919
Chubb Security will be installing one (1) manual fire pull station at the north front door and one (1) manual
fire pull station at the south back door to hall. Chubb Security will also install one (1) strobe only in the
existing restroom and one (1) horn/strobe in the front customer area. These devices will connect to the
existing FCI fire alarm control panel. The existing smoke detection devices and existing horn only device
will remain. Included in this submittal are three (3) copies of specification sheets of the devices that will be
installed. Please give me a call if you have any questions.
Al Land
Al.land@chubbsecuritv.com
206-652-0914 office
206-786-7348 cell
206-521-5340 fax
?AllD
NOV 212005 14Y--
Tukwila Fire
0
0
fl
--171
m N„ "IZI
c g 3 o
0 3 Nal- 0 ID m... -0
11:: �
1 ,c c c•n 0
C)-- nim o o
D=Si>�
NNQ
i' Cl.° A0El raN=aD-0. • - 0 0, ci Q. -o C
C w 0-
0
N Q cia) = F O
CD QcD Q. n_ cn rad o 7 =
• nn iaa-•oma.+• nr�a To,o
. c.o
cD '- b cr cU NI aa. co �
a) Q. a) CD 0 Q
c .. T Q tD
cfnn c ra = o El co
O -
QQ.a-= R 0 7
1
D' cD(0a)-, ow
o , - oo�° T
6 v rn a
0
co
t1/4
cl
war ori
0
Ye-CEi v ED
,AEG. 13 1990
HOLMES ELECTRIC
FILE
_ DRAWN 5Y AA INC.
'/er= I OF
TO PANEL
Wixi yes
k3/4,.Na+nfen
Twits
SMCKE DETECTOR 301P FCI
SMCKE DET ABOVE CEI LING
Q (EMOTE PLATE
HORN
RAI -2 ,FCI
HMVP FCI
TUKWILA FIRE DEPARTMENT
Please ca,I: 575-4407
and gives this job
No. ,13....Y1
and exact address for shut-
down or restoration ap)roval.
.=GROFF NUTRITION
=SOUTH CE14TER PLAZR
`TUKWILA) Wk.
re:
I u.,
•
,
r:
E, LETTER
.:1. -,roto hove been
1? City of
1 )ns
Ings.
DAIL: fr 11-9p j "__
romm
DEC 1t 1990
P A. I A
HOLMES E LEGT_RiC.�'
7255-8000
TO EXISTING
NOTIFICATION DEVICE
NN -DUSTING PULL STATION
DaS11NG H
DUSTING
z
TO EXISTING
INITIATE DEVICE
NG H/S
TO EXISTING
NOTIFICATION DEVICE
TO EXISTING
INITIATE DEVICE
DUSTING H/S
1__70STING SMOKE
OFLOOR
PLAN
SCALE: 1/4" a 1'-0"
Daum G PULL STATION
NORTH
J
\D
<WIRE SCHEDULE>
-Z-: 14 AWG 2 CONDUCTOR
-X-: 16 AWG 2 CONDUCTOR
<CANDELA RATE NOTE>
1. 75 CANDELA FOR HORN/STROBE
2. 15 CANDELA FOR STROBE
<INITIATING DEVICES AND FIRE SAFETY CONTROL FUNCTION>
1. SMOKE
2. FIRE SPRINKLER HEADS
3. INITIATING DEVICES (1,2) ARE MONITORED BY FIRE ALARM
CONTROL PANNEL WITH CENTROL STATION
SY
vBOL
L
-GLAD
)SYMBOL
OTY.
PAT #
DESCIPTIO\
..
1
S'
STO3E
S
`No.
Revieion/Ixue
Dot
4
P2.
H0\/STR03E
0
OO
5
2WE
SMO<E
CIRCUIT CONTINUED
FROM EXISTING DEVICE
RIS
-R
AG
'A
v
IRCUIT CONTINUED
FROM EXISTING DEVICE
D
CIRCUIT CONTINUED
TO EXISTING DEVICE
IRCUIT CONTINUED
TO EXISTING DEVICE
Generol Notea 1
PAID
SEP 19 2013
TUKWILA FIRE
cc x6.29V
11 /4"=1'
`No.
Revieion/Ixue
Dot
rim Nom and ua..
NW ELECTRIC SERVICE INC
(NWELEES925DL)
32419 3RD AVE SW
FEDERAL WAY WA 98023
206-778-7970
Project Nnarof Addras
F- eea tll7 gem"
Su„ 4(AC evkfiw
#33/ 3 ek&W
��kw Zok, �a
'TIRE ALARM
.*
09/15/2012
01
11 /4"=1'
ACCEPTED
Without Comments
As Noted in Red
0 Per The Attached Letter
re plans have been reviewed by The T Fire ;i
,:ration Bureau for conformance with current ity ,
7:ards. Acceptance is subject. to errors ---
aions which do not authorize violations of adopted
:cards and ordinances. Tne respons!bility for the
suacy of design rests totally with the designer.
dons, delet!cf 3 or revisions to these drawings after
Date will void this acceptance and will require a
::s��ixnittalof revised drawings for subsequent approval.
-'nal acceptance is subject to field test and inspection by
ine Tukwila Fire Prevention Bureau.
Cf-)."?‘ I
Date: (� By: J 4 1
T I KWILA FIRE DEPARTMENT
Please call 205-575-4407 and
give this Fire Permit No.
F -
and exact addrr ss for shut-
down
hutdown or restoration approval.
NOTICE
4 completed, signed, Tukwila
Fire Department Pre-test
Certificate must be presented
to the Inspector prior to
-commencement of Acceptance
Testing of any Fire Alarm
and Detection Systems.
Failure of test will result
in a Re -inspection Fee and
'ermination of the testing
"L" Beauty Bar
PROJECT LOCATION
Strandler Boulevard
REDUCING COUPLING
2"
3/8" MIN.
1" MAX.
SPRINKLER 'OOPS' PLATE
FOR SEISMIC
DETAIL of RECESSED PENDENT
NTS
FlexHead Sprinkler Drop
Corrugated stainless steel hose with stainless steel braid
ravailable in 2', 3',4',5' & 6' legnths
Multi -Port Bracket
Adjustable Hub
,FLEXHEAD
I NO U.5111 Eo,14
Flexhead Commercial Ceiling Unit
T -Bar Calling Installation
Model #2024,2036,2048,2060,2072
FLEX HEAD @ T -BAR CEILINGS
•
existing 1-1/2
:XIT I
J
t
mimilmsemniom
1?-
D
_,
Q„Q
417
{
Ir
411
1::
••.
G
4
D
L
=r —1
40•:}
r•
-- SIT
.7171. ,MINN,
TENANT SPRINKLER PLAN
SCALE: 1/4" = 1'-0"
0 2' 4'
8'
12'
LEGEND
1
EXISTING PENDENT SPRINKLER TO REMAIN
❑ Without Comments
❑ As Noted in Red
Ff Per The Attached Letter
T -h ese plans have been reviewed by The Tukwila Fire
vention Bureau for co for rmance with current City
rarsdards. Acceptance is subject to errors and
•
si scions which do not :uUiortze violations of adopted
•°_andards and ordinances. The responsibility for the
adequacy of design rests totally with the designer.
Additions, deletions or revisions to these drawings after
this date will void this acceptance and will require a
resubrnit�tal of revised drawings for subsequent approval.
Final acceptance is subject to field test and Inspection by
The Tukwila Fire Prevention Bureau.
Date: (I-Ice"I5 By:A7'v1)
EXISTING, PENDENT SPRINKLER RELOCATED TO NEW LOCATION
QTY: 4
's, ADDED PENDENT SPRINKLER
TYCO TY -FRB CHROME RECESSED PENDENT 1/2" 155° TY3231
QTY: 4
1-1/2" EXISTING BRANCHLINE
TUKW\ITLA FIRE DEPARTMENT
Pease cell 206-575-4407 and
give this Fire Permit N0.
13 -S -2,o7
and exact address for shut-
down or ram approval.
GENERAL NOTES
SCOPE OF WORK: ADD/ RELOCATE PENDENT SPRINKLERS FOR TENANT IMPROVEMENT WORK
SPRINKLER SYSTEM DESIGN PER N.F.P.A. #13 2010
ALL MATERIALS SHALL BE NEW AND U.L. LISTED OR F.M. APPROVED
EXISTING SYSTEM HYDRAULICS ARE NOT EFFECTED BY ADDED/ RELOCATED SPRINKLERS
NEW 1" PIPING TO BE 'DYNA—THREAD'
ORDINARY HAZARD — 130 S.F PER SPRINKLER
GENERAL LEGEND
—o
-4
BOO
BOB
BOJ
FOS
FOW
EARTHQUAKE BRACING
PIPE HANGER
GROOVED CAP
RIGID COUPLING ( UNLESS NOTED )
CAP
PLUG
CENTERLINE
HYDRAULIC REFERENCE POINT
EENTERUNE PIPE TO BOTTOM OF DECK
CENTERLINE PIPE TO BOTTOM OF BEAM
CENTERUNE PIPE TO BOTTOM OF JOIST
FACE OF STUD
FACE OF WALL
FOC
AFF
cH
R.C.
E/C
C/C
C/E
GG
TG
TxF
ATR
FACE OF CONCRETE
ABOVE FINISHED FLOOR
CEILING HEIGHT
REDUCING COUPLING
OUTLET COUPLING
WELDED OUTLET
"FIT' FITTING
END TO CENTER
CENTER TO CENTER
CENTER TO END
GROOVE/GROOVE
THREAD/GROOVE (ALSO "GT")
THREAD/"FIT" (ALSO "Fxr)
ALL -THREAD ROD
THESE DRAWINGS ARE THE PROPERTY & COPYRIGHT OF NORTHWEST FIRE SYSTEMS.
ALL RIGHTS ARE RESERVED. ALL NOTATIONS, DESIGN, AND INFORMATION CONTAINED
HEREIN SHALL NOT BE USED BY ANY OTHER ENTITY FOR ANY OTHER WORK, PROJECT,
OR CONTRACT. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED
DIMENSIONS AND ALL SHOULD BE VERIFIED ON SITE PRIOR TO INSTALLATION.
REV
DATE
BY
DESCRIPTION
n
PENDANT SPRINKLER STYLES
PENDANT WITH
PENDANT WITH SEMI -RECESSED
401 ESCUTCHEON ESCUTCHEON
PENDANT WITH
CONCEALED
ESCUTCHEON
n
n
n
n
Saving lives
Pr feeling Properly
"L°" BeautyBar
Southcenter Plaza Suite #337
Tukwila, WA
Date: 8/13
Drawn By: G.B.
Checked By:
s
TUK
NORTHWEST FIRE SYTEMS
7815 SOUTH 180TH ST. KENT, WA 98032
0 .206.772.7502 F .206.772.7504
WWW.NWFIRESYSTEMS.COM
LICENSE #NORTHFS928CR
Scale: as noted
Job #:
1 of 1
PAID
-4 2013
ILA FIRE
cE2-4D
(HR RMrE
EY5TPV4
To F
APJ'El_
A
FRo14 EYt5 1146-
E3EA- CKT,
1/8"=r -o"
w
FCI REMOTE, IND. RAI -2
FCI • SMOKE DET.- 301P
FCI HORN HMVP
TUKWILA F1FE DEPARTMENT`
Please call: 575.4407
and give this job
No.,_7773
and exact address for shut-
down or restoration approval.
GROFF NUTRITION
SOU1'HCENTER PLAZA
TUKWILA, WA
mss/ s Z -c
SEATTLE INDUS IAL CORPORATION
PO BOX 3557
SEATTLE, WA 98124'
(206)762-7551
WITHOUT COMMENTS.
❑ AS NOTED IN RED
❑ PER THE ATTACHED LETTER
The drawings affixed hereto have been
reviewed and accepted by the City of
Tukwila Fire Dept. Additions, deletions
or revisions to these drawings after this
date will void this acceptance and will
require a resubmittal of revised drawings.
Final acceptance is subject to field-
inspectijn by a representative of this
dep,rtn;;ent
DATE:
CITY OF TUKWILA
575-4407
•
sG rp
L
•11 JUN 1'.1991
DRAWN BY: ABSCO ALARMS, INC
(206)367-1166
Date: •6/12/91
'O
1
O
N
cD)
O
1
- - -
r
AREA OF WORK
20'-0"
l
i
BUILDING 'A'
KEY PLAN
NO SCALE
CORRIDOR
STOCK ROOM — EXP.
C
[XIS ,NG UPRIGHT WITH PLUG DOWN
—�EXISTIN7-21'rIRANCI-LINE
-14
SALES AREA
Wm, MO
TENANT SPRINKLER PIPING PLAN
1/8" =
• NEW 1/2" PENDENT SPRINKLER — 10 TOTAL
DESIGN PER N.F.P.A. AND FACTORY MUTUAL STANDARDS
SHELL HYDRAULICALLY CALCULATED TO .15 / 2500 S.F.
Nedo/ o
We Affteciat6 you
lame
TUKWILA ;IRE �..EPARTUIE1'fY
Please ca:l: 575-4407
and give this job
No. 9eL/34i
and exact address for shut-
down or restoration approval.
ftCCEPTED
WITHOUT COMMENTS.
0 AS NOTED IN RED
El PER THE ATTACHED LETTER
The drawings affixed hereto have been
reviewed and accepted by the City of
Tukwila Fire Dept. Additions, deletions
or revisions to these drawings after this
date will void thi aoce of In;e and will
require a resubmittal of revised drawings.
Final acce)tsnce su'aject to field-
inspec`iJn ay a representative of this
depart' :ent
DATE:/%:2-1 -16t3Y:...._ ..� r.
CITY OF TUKWILA 5--)3
575-4407
r.E
.... -y................
. .. ...+ .
P A L D
N
4
J cs
EL _...„
a❑
CC
w
L c,Z
a _,...., ir_Q Qli
�O
C� c ¢
„,
Es z Z t..:e
Lai
7
0
N
0
4932 PIONEER ROAD
N
0
00
W
0
m
Date: 11-12-90
Scale: 1/8' = 1'-0"
Drawn: G.B
Sheet: r'1 r,,.
l
CO
M
14
20'-0"
i \
i
J 1 J
---# . --moi
I 1
1 /J
RELOCATE 3 UPR1GHIS
r
1
NEW 1' ARM—OVER FROM
COSTING 1' PLUG DOWN
---~---r---f-- --�
r:
EXISTING 11/2" BRAkULIN S
- ;-
i
-
jemmy
I
-4
1
W16x 26
•
•4-
t i $; i - i
TENANT SPRINKLER PIPING PLAN
1/8._1,-0.
•
AREA OF WORK
fi
BUILDING 'A'
KEY PLAN
NO SCALE
• NEW PENDENT SPRINKLER — 15 TOTAL
0 RELOCATED UPRIGHT SPRINKLER — 3 TOTAL
DESIGN PLEB NFPA X13 — ORDINARY HAZARD 130 S.F. PER SPRINKLER MAX
rA
ITIiCUTCOMr a.NTS.
3 NOTED IN RED
Eil THE ATTACHED LETTER
edTho drawings affixhereto have been
reviewad and accepted by the City cf
Tukwila Fire Dept. Additions, delsti�ns
s
Or revisions to these drawic,s aftsr this
date Will void this acce;pt:m and will
require a resubmittal of revised Drawings.
Final acceptance is subject to field -
Inspection by a representative of this
department
DATE: /3 %/ BY: _!�
CITY OF TUKWILA
575-4407
TUKWILA FIRE DEPARTMENT
Please call: 575-4407
and give this job
No. %//Ude
and exact address for shut.
clown or restoration approval.
P 1A I l)
fifer
Date:.. 5-91
4932 PIONEER ROAD - 8OTHELI, WA. 98012
PH. (206) 481-7669
Scale: 1/8" =
Drawn: G.B
Sheet 1 OF 1