HomeMy WebLinkAboutPP - 339 STRANDER BLVD - MIZU STEAKHOUSE & SUSHI - PERMITS AND PLANS339 STRANDER BLVD
ASSOCIATED PERMITS
04-F-004
03-S-158
03-S-145
90-0097
900057
3301 SQA/
BATTERY STANDBY REQUIREMENTS FILE
DATE: —9/0°
JOB NAME: 660CW,cJ TFC i"/9Z'9 oF3 /G i9L—L
F.I•RE ALARM PANEL
•
QUANTITY
6TANDBY CURRENT
(amps DC
EACH TOTAL
ALARM CURRENT
(amps DC)
EACH TOTAL
cC`--702.-I ee,v7-;CD4-
/
, p63
: DC;3
,370
=375
Z- Pic -'I ZD,iJ pT. /WI),
6
b E o
. D 3h
i /G 3
,321
3'5/"1 S,W/tiiiltE '.SUPi//foz),
I
:c, 27
10.x.7
.1)69
166
INITIATING TFVTCFS•
.2,2 t1.3
+000041
�6OI y
x
!
�
,q6
/oU
,StfO
.51-ef
St -X- -,o2 `/ /c s /7zW E Pe T
,9z, -PM -!.53—/f/5—a-zL /-/-e.:;.7 J 7
yy
SIGNAIIING DFVTCFS
x'
.
.c 7 3
, 2_2-1
Z- /,,,2-e) / Z/t/5
40 ± 3
A— k-
,t36—
'3/5
ara7N•3i
Total standby current: + 1 R7 y
X standby hrs needed :_
Total 3+64
X derating factor: ', a (2-07o
Total 3.4-66)
Total alarm current: d?•3�
fraction of hr I 1
needed . 6E,/
/ J
Total ,1%
Total standby 3 %
+ total alarm
3.2‘' Total amp -hour needed
FILE
Battery Load Calculations
Device Quantity Standby Alarm Total. Total
Standby Alarm
Panel 1 .063A .37A .063A .37A
FCI Model FC -72
2 -Zone Module 8 .006A .32A .048A 2.56A
FCI Model ZDM-6
Smoke Detectors 115 .0045A .15A .52A 12.42A
Hochiki America
Model SLG -24F
Horn Only 15 N/A .18A 2.7A
Faraday
Model # 6230-B
Horn Strobe 15 N/A .14A 2.0A
Wheelock
Series AMT
Strobe Only 3 N/A .128A .384A
Wheelock
Series RSS
Total current draw for 24 hours of standby is 15.14A, and, 5 minutes in alarm is 8.164A
Current batteries in place are: (1) 12v 7AH, and (1) 12v 18AH
0 - -6O
101 Replace the existing smoke sensor below the
ceiling with 15f R/R 135f Fixed heat sensor.
102 Install New Device
103 Move the existing horn only and replace with
a new horn/strobe.
104 Replace the existing horn only with a new
horn/strobe.
105 Existing device below drop ceiling.
106 Existing device above drop ceiling
107 Use the existing smoke sensor from 101
replacement and install it in this location.
(77
Smoke Sensor
Existing.Fire Suppression System (Range
Gard)
15f R/R 135f Fixed Heat Sensor
Manual Pull Station
Horn/Strobe
S (-�o6e vl
w n.. w.. M -w r.. .e. +r a w a+ — t .
�.1. .0 M M. M .....Y ...
CCEPTE
Without Comments
As Noted In Red
Per The Attached Letter
These plans have been reviewed by The Tukwila Fire
Prevention Bureau for conformance with current city
s :andards. Acceptance is subject to errors and
omissions which do not authorize violations of adopted
andards and ordinances. The responsibility for the
dequacy of design rests totally with the designer.
dditioris, deletions or revisions to these drawings after
I -is date will void this,acceptance and. will require a
esubmittal of revised drawings for subsequent approval.
nal acceptance is subject to field test and inspection by
ne Tukwila Fire Prevention Bureau.
ate: rffir Oci By: D2 ‘7.0
1'
1/0-p
NOTICE.
A completed, signed, Tukwila Fire
Department Pre-test Certificate must be
presented to the Inspector prior to.
commencement of Acceptance Testing of
any. Fire Alarm and Detection Systems,
Failure of test will result in $40 Re-
Inspection Fee and termination of the
testing.
T Z O S I E/4 4K -H" O 7
3 7 S revvkr /!'id
I'UKWILA FIRE uEPAR TMLtv7,
Please call: 575.4407
and give this job
No. O ♦coo y
and exact address for shut=
clown or restoration approval.
V1
. .r I1.. "-om.`,X1%2
ry9 2 200 3 -3?,;" --'"a" i!
H00132
HOOD 3
HOOD 4
HOOD 5
HOOD 6
HOOD 1
oaio.16,
Hon S OUCT 9'5(9"
,RANOE. 5.V5-1611
ciAs azi Di) IS,
UL -
300
13 HOODS oNE §Y5TE
HOOD 8
HOOD 10
AK 1-100D
11,{014.2••••.7•4/5,3•1.74,0,.....M114.7(
IT
601011
NW. up Mk
HOOD 12.
H000 13
Itt*,
/...KW.00,14,0,S,P•Se**
- „ -
N.1.110.-4
I -100D 161 DUCT 18"x 18"
....••••••••••••wous••••••re.........
r
4av
t.
qm_LD1 WET %Wt.
• ohoRm
oriauip AIR.
1 T
ghS GrAS
Pyaz aiRalw
0
CCE
I e•"*,
Without Comments
As Noted In Red
Per The Attached Letter
rat
These plans have been reviewed by The Tukwila Fire
Prevention Bureau for conformance with current city
standards. Acceptance Is subject to errors and
omissions which do not authorize violations of adopted
standards and ordinances. The responsibility for the
adequacy of design rests totally with the designer.
Additions, deletions or revisions to these drawings after
this date will void this acceptance and will require a
resubmittal of revised drawings for subsequent approval.
Final acceptance is subject to field test and Inspection by
The Tukwila Fire Prevention Bureau.
Date: 7/1-3 /0 By:
TUKWILA FIRE DEPARTIVILtle
Please call: 575-4407
and give this job
0 3
No:
and exact address for shut.
down or restoration approval,.
Hio-
PO BOX 585 "T
31 UKWILA:, Wk 90138
$98,Ko
$4f44ty
(425) 445.3473 HIJ.FIRE
S 9 200
2_41%-e--
M.O.W.1.07
Ada...61,101.tm,
•
•
44
•
a.
C.
I; ;Itt) :14 T Sd:Cdt• ;CI ki).C3t kk....
14, -tfrUN
ewes
•
on t
•
ims- a 3 A•g tZgil);113
as I 2 3 1 riiitit
,---1 22 er;2•5 tii
(s) 4 et.1§1• .!x
ig gia!
•
•
•
si
7-2 fa
AJapi pmroateverdiai 7:nd equipmen_ t to be new and underwri ers
2. Piping dimensions are end to end.
3. Pipe hangers and method of hanging to be in accordance
4. Earthquake bracing and joining of plie art fittings shall be
-5. Owner to provide a minium 014700. F to preventwater in pipes
from freezing in areas Protected by a wet pipe sprinkler
S. Structural adequacy of the building to support the sprinkle
piping is the resporisibility of the owner and or his structu
•
SYM
•
SPRINKLERS USED
SPRINKLER - ORIFICE
EX ST Tee-Att
rz Paw EA/7"
QUAN
TEMP
•
155
aro
- FIRE SPRINKLER SPECIALISTS_:
41021 CRAMER RD.. KP.N.
GIG - HARBOR, VA - 98329
PHONE 857-2056
TO EXISTING
HORN CIRCUIT
>TO CONTROL
PANEL
FROi-1 EXISTING HORN
CIRCUIT
` c�i•13h
JI—
ExsflnRine'
BIGA\DTALL -3=/
SOUTHCENTER PLi
U KVV I L A 9 WA- - Please call: 575-4-407
WILA FIRE DEPARTMENT
and give this job
No %0-0057
and exact address for shut-
down or restoration approval.
WIT'
❑ Av
❑
The drawl;
reviewed:
Tukwila Fir
or revision;
date will
require a rc -
final ar,
TSD
.i MENTS.
i REO
. i .ACriED LETTER
hereto have been
by the City of
••. 3ns, deletions •
.,1 ,gs after this
. and will
,e-,ised drawing$.
;oct to field-
_e.itative of this
5100 _ /a
• CII { OF TUKWILA
575-4407
SYMBOL
MANUFACT,
MODEL
DESCRIPTION 1
O
HOCHIKI
SLG -24F.
SMOKE. DET.
-�-
HOCHIKI
HA -RA -1
REMOTE IND.
C3�
FARADAY
6120/5003
MECH. HORN
-ABOVE CEILfNG
4)
in MAY
i
------------- t `
3 1990 pi
Fi
HOLMES ELECTRIC
(206) 235-8000
5/I/90
DRAWN BY A.A.1NC.
L.
0
N
1\
,
t
20'_0„
20,_0„
20,_0„
AREA OF WORK
U
Dr
-1
rJ
111
1;1 1V2" BRANCHLINES-- -TYP.
NRMOVER & DROP
z -
1
01
1.7116111
0
ITERN' TION
NEW PENDEN
RI LER
H
1,4
L DIAMOND 6�.x 14,
1. I
*16x 26
r
BIG AND TALL CHOP
TENANT SPRINKLER PIPIG PLAN
1/8" = 1•- O"
BUILDING 'A'
KEY PLAN
NO SCALE
• NEW PENDENT SPRINKLER - 31 TOTAL
TUKWILA FIRE DEPARTMENT
Please call: 575-4407
and give this job
and exact address for shut-
down or restoration approval.
CCEPTED
WITHOUT COMMENTS.
AS NuTED IN RED
0 PER THE ATTACHED LETTER
The drawings affixed hereto have been
reviewed and accepted by the City of
Tukwila Fire Dept. Additions, deletions
or revisions to these drawings after this
date will voi J thi; accept -Ince and will
require a resubmittal of revised drawings.
Final acceptance is su'aject to field-
inspecl;:a by a re,,,resentative of this
del.- rV-7 ent
DATE: }--9,2 BY:
CITY OF TUKWILA p�
5i5-440/
d, 4;1/1 r
circ ✓P�{�i,i=t%
FACTORY MUTUAL ENGINEERING ASSOCIATION
SEATTLE DISTRICT OFFICE
PLANS ACCEPTED SUBJECT TO CHANGES INDICATED AND COMMENTS
IN TRANSMITTAL LETTER.
FM approved equipment shoula be used and the Installation should conform to FM
recommended gooc practices. Final acceptance of this lop is subject ro field exam-
ination anc will only be given when materials and tests neve been certified using
National Automatic Sprinkler ane Fire Control Association Form e5 or eou,velent. A
separate farm should be submitted rot each riser this acceptance •s vbtd if there
ire fluorescent tights or other or>structtons not clearly shown on theta prints. L,ie•
bility of the FM companies is Iimitea to their insurance policy eoverge3.
iIM/ efj br
�R.
Dgt
EA _ED
N
uf<
I
J
t•¢ --
J
Z
d 1--
V•y Z
(=Jf
� d
03
Q
� Y
d
CLLAJ
0
0
0
4932 PIONEER ROAD
BOTHELL, WA
PH. (206) 481-7669
Dote: 2-90
1AR 2 i 10t fl f
,.'Drown: G.B
Scale: 1/8" = 1/-0t
Sheet: 1 OF 1