Loading...
HomeMy WebLinkAboutPP - 377 STRANDER BLVD - BEAUTY DIRECT - PERMITS AND PLANS377 STRANDER BLVD ASSOCIATED PERMITS 14-F-154 14-S-122 ariFICIEFIS SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** King Co. Assessor's Tax No.: Site Address: 377 Strander blvd tukwila wa 98188 Suite Number:377 Floor: 1 Tenant Name: Beauty Direct New Tenant? ❑ - Yes ❑ - No Property Owner's Name: Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Lamonte Day Telephone: 206-571-3955 Company Name: First Defense Fire Protection LLC Mailing Address: 10212 215th ave S.E. Snohomish WA 98290 �a E-mail Address: firstdefensefire@hotmail.com City Fax Number: 360-794-s011 Zip Total number of new/relocated devices or sprinkler heads: 25 Valuation of Project (contractor's bid price): $ 6.200 Scope of Work (please provide detailed information): Add heads below new mezz & drop heads in new ceiling areas all to 130sf max nfpal3 PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: 1-41.44Withi- Alt4 9 Signature: Print Name: Lamonte Mang Plan Permit App.doc Date: 6/3/14 Day Telephone: 206-571-3955 1/2/13 TFD FP Form 8 SITE LOCATION CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** PAID TU WIPLILq FIRE ]l King Co. Assessor's Tax No.: 2 Site Address: J511 ik4 Q t V L` Suite Number: Floor: 4 Tenant Name: I✓eD\ve CT Property Owner's Name: Mailing Address: City State Zip CONTACT PERSON -if f there are questions about the submittal. c NameS(Y l �]€(V\ Day Telephone: �l.J Company Name: ?O\C\Q\C_ V JCS U Mailing Address: L—U C(y \O( ? l J Q WA q(dso\1 \� (� c City State Zip E-mail Address: ACS t\ VO\C lC.'� l Q & CLAY 1A11� , Ccrr l Fax Number: Total number of new/relocated devices or sprinkler heads: \J —1 New Tenant? S- Yes ❑ - No Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Pcaa,A, eAm i - PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: L./ /A,,,d I Date: 7— N — V4 Print Name: M. ` f u..0\ Day Telephone: ! \P n— l Plan Permit App.doc 1/2/13 TFD FP Form 8 FIRE DEPARTMENT SPRINKLER PLAN REVIEW COMMENTS Project Name: Permit No.: Date: Reviewer: Beauty Direct 377 Strander BI 14-S-122 June 5, 2014 Al Metzler Fire Protection Project Coordinator (206) 575-4407 option # 2 (Inspection Requests) (206) 971-8718 (Plan Review Questions) • Lateral sway bracing is required at a maximum spacing of 40' for all mains, cross mains, and branch lines 2.5" and larger. Bracing is provided for the last length of pipe but within 6' of the end of a feed or cross main. Bracing is required unless all the pipe is supported by rods Tess than 6" or by 30 ° wrap-around U -hooks for any size pipe, 9.3.5.3. • Minimum clearance around pipes: 2 " for 1 "-3.5", 4" for 4" and larger, see 4 exceptions, 9.3.4. • Longitudinal sway bracing is a maximum of 80' for mains and cross mains and within 40 ' of the end of the line, 9.3.5.4. • Provide lateral and longitudinal bracing for changes in pipe direction per section 9.3.5.11.2 for pipe size 2 1/2 inches and larger. • Restrain branch lines at the end sprinkler of each line, restrain against vertical and lateral movement, 9.3.6.3. • Restraints for branch lines shall be at intervals per table 9.3.6.4 and section 9.3.6.4, and restrain sprig ups greater than 4', 9.3.6.6. • Comply with ASCE 7-05, section 13.5.6.2.2. • Provide sprinkler protection beneath all obstructions greater than 4 ft. in width. • Extend sprinkler protection to all combustible concealed spaces. • Comply with NFPA 13 obstruction tables. • All valves controlling the water supply for automatic sprinkler systems and waterflow switches on all sprinkler systems shall be electrically supervised. • Comply with obstructed/non-obstructed construction rules for sprinkler head placement. • Sprinkler heads spaced closer than 6 ft. apart must be baffled. • Modifications involving 20 or more heads require hydrostatic test and system isolation if necessary. • For dry pipe and double interlock preaction systems, in addition to the standard hydrostatic test, an air pressure leakage test at 40 psi shall be conducted for 24 hours. Any leakage that results in a loss of pressure in excess of 1.5 psi for the 24 hours shall be corrected. • These conditions apply to all sprinkler piping exposed as necessary to accomplish the permitted scope of work. All code references are NFPA 13, 2013 Edition. FIRE ALARM LEGEND Symbol Description Manufacturer Part# Mounting FACP FIRE ALARM CONTROL PANEL - EXISTING SILENT KNIGHT SK -5700 SELF CONTAINED AWG ADDRESSABLE SIGNAL BOOSTER POWER SUPPLY- EXISTING SILENT KNIGHT SK -5495 SELF CONTAINED BPS# A REMOTE ANNUNCIATOR - - SELF CONTAINED ANN RED F MANUAL FIRE ALARM STATION SILENT KNIGHT SD500-PS 4 SQ DEEP W/1 GANG O PHOTOELECTRIC SMOKE DETECTOR - - 4 SQ DEEP W/30/ 0 ADDRESSABLE 135° FT/ROR HEAT DETECTOR - - 4 SQ DEEP W/30/ B DUCT SMOKE DETECTOR BY OTHERS BY OTHERS BY OTHERS ADDRESSABLE NOTIFICATION MODULE - - 4 SQ DEEP ANM ADDRESSABLE INPUT MODULE - - 4 SQ DEEP AIM ADDRESSABLE RELAY MODULE - - 4 SQ DEEP ARM Ell MULTI CANDELA WALL MOUNT HORN/STROBE - - 4 SQ DEEP #14/2 HIGH CANDELA WALL MOUNT HORN/STROBE - - 4 SQ DEEP 11)1 MULTI CANDELA WALL MOUNT STROBE - - 4 SQ DEEP ' Van1p WEATHERPROOF STROBE- - WPSBB-R CD 10" RED BELL - - WBB ET11 MULTI CANDELA CEILING MOUNT HORN/STROBE WHEELOCK HSC 4 SQ DEEP W MULTI CANDELA CEILING MOUNT STROBE WHEELOCK STC 4 SQ DEEP WATER FLOW SWITCH BY OTHERS BY OTHERS BY OTHERS WF - BLACK TAMPER SWITCH BY OTHERS BY OTHERS BY OTHERS TS E PIV POST INDICATOR VALVE BY OTHERS BY OTHERS BY OTHERS #16 *II* DRY CONTACT (FIRE PUMP CONNECTION) BY OTHERS BY OTHERS BY OTHERS METALLIC RACEWAY SINGLE CONDUCTOR WIRE LEGEND OPEN RACEWAY MULTICONDUCTOR CABLE LEGEND COLOR AWG QTY TYPE LETTER FUNFTION LETTER TYPE QTY AWG COLOR - BLACK #16 1 THWN-SOLID A ADDRESSABLE INITIATING A 16/2 - FPLP 1 #16/2 RED + RED #16 1 X CIRCUIT - BLACK #16 2 THWN-SOLID B ADDRESSABLE INITIATING B 16/2 - FPLP 2 #16/2 GREEN + RED #16 2 X CIRCUIT LOOP - BLUE #14 1 THWN-SOLID C HORN / STROBE C FPLP 1 #14/2 BLUE + WHITE #14 1 X CIRCUIT X X X - BLUE #14 2 THWN-SOLID D HORN / STROBE D FPLP - 2 #14/2 WHITE + WHITE #14 2 X CIRCUIT LOOP X X X - BLACK #16 1 THWN-SOLID E CONVENTIONAL INITIATING E 16/2 - FPLP 1 #16/2 YELLOW + YELLOW #16 1 CIRCUIT - BLACK #16 2 THWN-SOLID F CONVENTIONAL INITIATING F 16/2 - FPLP 2 #16/2 PURPLE + YELLOW #16 2 CIRCUIT LOOP BLACK #14 1 THWN-SOLID G 24V DC POWER G FPLP 1 #1412 BLACK + RED #14 1 CIRCUIT RED #14/2 1 TWISTED SHIELDED H SPEAKER CIRCUIT H TWISTED SHIELDED 1 #14/2 RED FPLP W/ DRAIN FPLP W/ DRAIN RED #14/2 2 TWISTED SHIELDED I SPEAKER CIRCUIT I TWISTED SHIELDED 2 #14/2 RED FPLP W/ DRAIN LOOP FPLP W/ DRAIN BROWN #16 1 16/2 - FPLP 1 #16/2 WHITE BLUE #16 1 THWN-SOLID J ANNUNCIATOR CIRCUIT J - BLACK #14 1 FPLP 1 #14/2 BROWN + RED #14 1 18/2 TWISTED FIREMAN'S PHONE 18/2 TWISTED RED #18/2 1 SHIELDED FPLP K CIRCUIT K SHIELDED FPLP 1 #18/2 RED W/ DRAIN W/ DRAIN 18/2 TWISTED FIREMAN'S PHONE 18/2 TWISTED RED #18/2 2 SHIELDED FPLP L CIRCUIT LOOP L SHIELDED FPLP 2 #18/2 RED W/ DRAIN W/ DRAIN - PURPLE #14 1 THWN-SOLID M CONTROL CIRCUIT M FPLP 1 #14/2 ORANGE + ORANGE #14 1 - PURPLE #14 2 THWN-SOLID N SPARE CONDUCTORS N FPLP 2 #14/4 RED + ORANGE #14 2 CABLE COLOR SUBSTITUTIONS ARE ALLOWED ON ALL LETTERS EXCEPT H, I, K, L. IF SUBSTITUTIONS ARE MADE, WIRE AWG & TYPE MUST REMAIN THE SAME & LEGEND MUST BE UPDATED & MATCH CORRECT WIRE FUNCTION. MULTI CONDUCTOR CABLE COLORS AVAILABLE: 16/2 = RED, WHITE, YELLOW, GREEN, DARK BLUE, PURPLE, ORANGE. 14/2 = RED, WHITE, YELLOW, GREEN, DARK BLUE, PURPLE, ORANGE, BROWN, BLACK THWN SOLID COLORS AVAILABLE: BLACK, WHITE, GREEN, RED BROWN, YELLOW, ORANGE, PINK, PURPLE, BLUE, GREY Pacific Fire & Security, Inc. Asbuilt- Requirements ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING PACIFIC FIRE & SECURITY, INC. WITH ACCURATE REDLINE DRAWINGS. DRAWINGS SHALL BED REDLINED AS NECESSARY TO SHOW THE FOLLOWING: DEVICE LOCATIONS - ADDS/DELETES CIRCUIT NUMBERS - ADDRESSABLE/SIGNAUZONE/AUXILIARY WIRE/CONDUIT - ACCURATE ROUTING WIRE FILL - USING WIRE LEGEND EOL - RESISTOR LOCATIONS PACIFIC FIRE & SECURITY, INC. WILL PROVIDE (UPON REQUEST) A BLANC SET OF FLOOR PLANS TO BE REDLINED. PACIFIC FIRE & SECURITY WILL, INCORPORATE ALL REDLINED CHANGES INTO THE RECORD AUTOCAD SET OF DRAWINGS. AUTOCAD ASBUILT COLOR STANDARDS RED - NEW GREEN - DELETED BLUE - NOTES TO DRAFTER SPECIAL NOTES: FIELD VERIFY LOCATION AND QUANTITY DESIGNATES DEVICE NUMBER 2 > DESIGNATES LEVEL OR CIRCUIT NUMBER -1 DESIGNATES TYPE OF CIRCUIT eg: SIGNAL CKT 2 DEVICE 1 S2- TYPICAL DESIGNATES DETAIL NUMBER WHERE THE DETAIL CAN BE FOUND DESIGNATES SHEET NUMBER •wP•= DENOTES WEATHERPROOF EQUIPMENT AND/OR BOX Global;Project Values.' Project Name: Project iD Prepared By. KNI gate; BEAUTY DIRECT : 14-J1174 7/16/2014 Standby Hours; Alarm Nuns; r4factor„ e Drop Warling h.eshold Vd: (E) BPS SK 5495 FIELD LOCATE t urrent,:L)r and b y AI 4'Drop > Notification Appl Circuit Notification Appl Circuit Notification Appl Circuit Notification Appl Circuit Notification Appl Circuit Notification Appl Circuit 0.904 #14 Solid 0.000 #14 Solid 0.000 #14 Solid 0.000 #14 Solid 0.000 #12 Solid Tofal Standby; 0.040 #12 Solid 6.30%" 0.00% 0.00% 0.00% 0.00% 0.00% Tofal Alarrti Current (A p Stendby Tii�e:Iri Hour Alarm Trneir Minute Tot ndby'AH Required 0:960 0089 Tctal Alarni AFI Require Total Combin re Multiply BY The. Derating' Facto um` Battery AmpHours: Required MAX NAC CKT AMPS: 3 MAX C KT AMPS TOTAL: 6 .Q.90_.' EOL 75cd IMI 30cd C S1-7 CE It�ll 15cd c S1-6 t 15cd c S1-5 0 Without Comments i As feted In Red 0 Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City }rndards. Acceptance is subject to errors and ::mis ions which do not authorize violations of adopted • nciards and ordinances, The responsibility for the :Elequacy of design rests totally with the designer. r°ditions, deletions or revisions to these drawings after I cis (Jaw wilt void this acceptance and will require a resubmittal of revised drawings for subsequent:approval. Final acceptance is subject to field test and inspection by Tne Tukwila Fire Prevention bureau. Date' % - 3 �'• TUKWIt.A FIRE DEPARTMENT Please call 206-575-1407 and give this Fire Permit No. F-lS`i and exact aMress for shut- down hutdown or restoration approval. HORN CIRCUIT FROM AUX. POWER SUPPLY 30cd C S1-4 It�ll 75cd C S1-3 II�It 177cd C S1-2 NOTICE A completed, signed, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to commencement of Acceptance Testing of any Fire Alarm and Detection Systems. Failure of test will result in a Re -inspection Fee and termination of the testing STROBE 1111 C S1-1 HORN/STROBE c EXISTING SILENT KNIGHT 5495 BPS A EXISTING SILENT KNIGHT 5700 FACP FIRE ALARM RISER N.T.S. STROBE HORN/STROBE HORN/STROBES & STROBES TYPICAL WIRING DIAGRAM CEILING 80" AFF TO CENTER OF LENS FOR WALL MOUNT UP TO 54" AFF TO OPERABLE PART AFFITTO APPROACH ART IFLFR�ONT APPROACH NECESSARY. FLOOR l A.D.A. REGULATION COMPLIANCE SWITCHES CONTROLS AND FIRE ALARM PULL STATION SHALL BE MOUNTED AT +48" TO TOP. FIRE ALARM INDICATING APPLIANCES SHALL BE PLACED 80" ABOVE THE HIGHEST FLOOR LEVEL WITHIN THE SPACE OR 6" BELOW THE CEILING, WHICHEVER IS LOWER TO A.D.A. GUIDELINES. EOL SEQUENCE OF OPERATIONS INPUT MANUAL PULL STATION SMOKE DETECTION HEAT DETECTION (IF APPLICABLE) DUCT SMOKE DETECTION (IF APPLICABLE) WET FLOW SWITCH WET TAMPER SWITCH POST INDICATOR VALVE SYSTEM TROUBLE OUTPUT LATCHING ACTIVATION OF LOCAL ALARM AT FACP X X X X INDICATION OF ALARM AT LCD ANNUNCIATOR (IF INSTALLED) X X X X ACTIVATE ALL AUDIBLE & VISIBLE DEVICES X X X X SHUTDOWN RESPECTIVE HVAC UNITS (IF APPLICABLE) X TRANSMIT ALARM SIGNAL TO CENTRAL STATION MONITORING X X X X TROUBLE/SUPV. INDICATION AT FACP X X X X TROUBLE/SUPV. INDICATION AT LCD ANNUNCIATOR X X X X TRANSMIT TROUBLE/SUPV. SIGNAL TO CENTRAL STATION MONITORING X X X X INITIATE ELEVATOR RECALL X X X X Fire Alarm System Check Off List For Final Inspection Following is a list of items that must be completed before the Fire Department will perform a final inspection. 1 Low Voltage Electrical Final Completion Date: 2 Line Voltage Electrical Final Completion Date: 3 Elevator Final Completion Date: 4 Pressurization a Stairwell Completion Date: b Elevator Completion Date: 5 Sprinkler System (100% Complete) All Valves in normal condition. Completion Date: 6 Interior Building Construction. Completion Date: (i.e. doors, floor covering, ceiling covers, ceiling tiles, windows, etc.) 7 HVAC Completion Date: 8 Suppression Systems Completion Date: 9 Safety and ADA Requirements, Fire Extinguishers Completion Date: 10 Specialty Furniture Completion Date: 11 Monitoring (See Below) 12 Final Fire Alarm Inspection Completion Date: 13 Approved Set of plans and permit on site Completion Date: Phone line (lines) must be installed and active. 0 14 Fire Alarm Monitoring Completion Date: a Dual Line Communicator Completion Date: b Scan Line Date Line Due In: (If Required by Jurisdiction) c Contract Signed Completion Date: d Scan Line ordered (Alarm Company) Completion Date: e Stu Installed and Tested Completion Date: Completion Date: 0 2 Elevator Monitoring GENERAL NOTES: 1) ALL WIRE AND CONDUIT MUST BE INSTALLED IN ACCORDANCE WITH PLANS AND SPECIFICATION, AND MUST MEET ALL APPLICABLE CODES. 2) ALL WIRE AND CABLE MUST BE RATED FOR FIRE ALARM USER PER THE LATEST REVISIONS, OF THE NATIONAL ELECTRICAL CODE SECTION 760. THIS ISA POWER LIMITED FIRE ALARM SYSTEM, ALL CABLE MUST BE MARKED FPL, FPLR, OR FPLP. 3) ALL CONDUCTORS MUST TEST FREE OF GROUND BEFORE MAKING CONNECTION TO THE FIRE ALARM CONTROL PANEL. 4) TO RETAIN WARRANTEE, THE FIRE ALARM EQUIPMENT MUST BE POWERED UP UNDER THE DIRECTION OF A QUALIFIED MANUFACTURER'S TECHNICIAN. 5) THE LIFE SAFETY SYSTEM IS A COMPLETELY SUPERVISED SYSTEM. 6) INSTALLING CONTRACTOR SHALL COORDINATE ALL FIELD CHANGES WITH THE MANUFACTURER INCLUDING CHANGES IN DEVICES, WIRE CONDUIT RUNS AND OPERATION IN THE SYSTEM. MANUFACTURER SHALL NOT BE HELD RESPONSIBLE CAUSED BY THOSE CHANGES. 7) LIFE SAFETY AUDIBLE SHALL BE AUDIBLE THROUGHOUT THE SPACE AND HAVE A SOUND PRESSURE LEVEL NOT LESS THAN 15db ABOVE AMBIENT NOISE LEVEL MEASURED AT 4'-0" ABOVE FINISHED FLOOR. 8) SYSTEM SHALL BE CLASS "B" IN CONFIGURATION. 9) LOCATE ALL PULL STATION AND HORN/ STROBE UNITS AT SPECIFIED HIGH PER NFPA 72 AND ADA SEE DETAIL. 10) SMOKE DETECTOR LOCATION ARE FOR REFERENCE ONLY AND SHALL BE INSTALLED PER NFPA 72 11) ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ROUGH -IN INSTALLATION WITH THE FIRE ALARM CONTRACTOR 12) SMOKE DETECTORS IN CEILING MUST BE LESS THAN 15' FROM A WALL AND / OR NO FURTHER THAN 30' FROM EACH OTHER. 13) NO SMOKE DETECTOR SHALL BE LOCATED CLOSER THAN 36" TO ANY AIR REGISTER OR DIFFUSER 14) NO HEAT DETECTOR SHALL BE LOCATED CLOSER THAN 24" TO ANY AIR REGISTER OR DIFFUSER. 15) NO HEAT DETECTOR SHALL BE LOCATED CLOSER THAN 36" TO ANY PART OF ANY HEAT GENERATION DEVICE (FUSE, BOILERS, WATER HEATER, ETC..) IN MECHANICAL ROOMS. 16) NO HEAT DETECTOR SHALL BE LOCATED CLOSER THAN 18" TO ANY PART OF LIGHT FIXTURE. 17) INITIATION AND SIGNALING CIRCUITS ARE SEPARATE YET MAY BE RUN IN SAME CONDUIT 18) ALL CONDUCTORS SHALL BE LABELED BY ZONE AND ALL COLOR CODES SHALL MATCH 19) ALL CIRCUIT FEED AND RETURN'S SHALL BE SEPARATED BY A MINIMUM OF 6' 20) THESE DRAWINGS DO NOT SUPERSEDE THE CONTRACT DRAWINGS AND SPECIFICATIONS, THEY ARE INTENDED AS A SUPPLEMENT ONLY AND MUST BE USED IN CONJUNCTION WITH THE CONTRACT DOCUMENTS. THEY DO NOT MODIFY THE CONTRACTORS OBLIGATION TO CONFORM TO THE PROJECTS ORIGINAL DESIGN CRITERIA. 828 Poplar Place South Seattle, Washington 98144 Phone: (206) 957-0907 Fax: (206) 726-8160 www.pacificfiresecurity.com PLOT DATE: 7/16/2014 Project Manager: JON LOVERN Design: DALLAS ANDERSON Drafter: KELSEY LUTTON Job Number: 14-J1174 Received Architects Plan: PFS REVISIONS REV DATE DESCRIPTION 07-16-14 PERMIT SUBMITTAL FIRE ALARM COVERSHEET FAO 1 TUR TSA Ia1ID� o- / 16--- t' UP TO S1-6® 0 0 0 0 0 0 0 0 0 0 S1-3 0 15cd\ 0 • 0 S 0 0 0 0 0 0 0 30cd 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TO BPS r V 0 0 0 It�ll 0 0 S1-2 75cd •0— FIELD LOCATE P 0 0 0 177c 0 0 0 0 0 0 1st FLOOR FIRE ALARM PLAN SCALE: 1/8"=1'-0" 0 0 0 0 0 0 0 0 MEZZ LEVEL FIRE ALARM PLAN SCALE: 1/8"=1'-0" 828 Poplar Place South Seattle, Washington 98144 Phone: (206) 957-0907 Fax: (206) 726-8160 www.pacificfiresecurity.com PLOT DATE: 7/16/2014 Project Manager: JON LOVERN Design: DALLAS ANDERSON Drafter: KELSEY LUTTON Job Number: 14-J1174 Received Architects Plan: PFS REVISIONS REV DATE DESCRIPTION 07-16-14 PERMIT SUBMITTAL FIRE ALARM FLOOR PLAN FAI.O A CE N O Without Comments Xi As Noted in Red ;1E( Per The Attached Letter these plans have been reviewed by The Tukwila Fire revention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations of adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions er revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance Is subject to field test and inspection by The Tukwila Fire Prevention Bureau. Date: - s-/ By: l (�1 �'`^ < 1' DN. TO MEZZ JOIST SPACE BELOW TYP. UPRIGHT SPKR BELOW STAIR LANDING — EXISTING PENDENT SPRINKLER TO REMAIN ABOVE I v r =rrT (11 %2r T 1 1�2 1% - . 14 CH. TEE TYP. 14 @S 1Y2 TO 112 Ll- ~I1 I17-7 1--iy III—I:-1II II — ® 14 X 1 STORAGE 1Y2 14 14 14 70 14 14 1 14 1 1 1— 1 14 I I —1 1u2 I 0 1Y2 N. N/ 14 /^\ / 14 1% 1 L --T-- ' SOFFIT AT ' 14 I J 2'-0" AFF 14 1Y2 — ---- 014° SCFFITS AT 13'-0" AFF > SALES AREA 1 1.4 14 14 11/1 1y2 14 EXISTING AND 1" PLJG UPRIGHT UPRIGHT 5PRINKLER FOR FLTURE SPRINKLEF 14 DRO'. S TO REMAIN ON 1/1/2X1 ALL EXISTING 14 TEE 14 " EXISTING PIPING TO REMAIN 3 14 14 NEW PENDENT FROM FLUGGED 14 SPRINKLER TEE TYP. 14 / / / 1% 14 112 1%//- / / / 14 / ' 14 — .. L ---'---.. • -- FIRST FLOOR PIPING PLAN ROOF PIPING PLAN TUKWILA KWILA Ff RE DEPARTMENT Reese call 206-575-4407 and g+vl this i��Permit No. and exact address for shut- down or restoration approval. NEW PENDENT SPRINKLERS TO BE 1/2" SEMI -RECESSED QUICK RESPONSE 155d, WHITE FINISH 25 TOTAL /X" PROVIDE HANGERS ON ALL ARMOVERS EXCEEDING NEW PIPING TO BE BLK STL SCH. 40 OR DYNA THREAD 2-I/4" DIA HOLE IN CEILING ---TJI OR PLAM BM 3/8" SAMMY SCREW ALL THREAD ROD 1/4" LAG SCREW CO) AFCON 514 OFFSET HANGER 7/16±1/8" I-1/8" MIN 2-7/8" DIA WOOD ATTACHMENT HANGER DETAIL OFFSET PIPE HANGER RECESSED PENDENT SPRINKLER WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS ILewis Peters 2800-0691-C Level 3 First Defense Fire Protection, L. L. C. FIRSTDF981 RP 1.3,2nature Expires 12/31/1.41 FIRST DEFENSE FIRE PROTECTION LLC SPRINKLERS BEAT FIREMEN TO THE BLAZE 10212 215th AVE SE SNOHOMISH, WA 98290 PROJECT ADDRESS CITY TITLE TENANT IMPROVEMENT FOR BEAUTY DIRECT 377 STRANDER BLVE. SUITE 377 TUKWILA, WA PHONE (360) 794-9479 LIC# 602-250-698 DRAWN LP DATE 6/2/14 CAD FILE FIRE SPRINKLER ALTERATIONS AND ADDITIONS