PP - 391 STRANDER BLVD - COMCAST XFINITY - PERMITS AND PLANS
391 STRANDER BLVD ASSOCIATED PERMITS 15-F-151 CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila, WA 98188 206-575-4407 Date application accepted: FIRE PROTECTION SYSTEMS PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. **PLEASE PRINT** SITE LOCATION 31 King Co. Assessor's Tax No.: Site Address:W Strander Boulevard Tukwila, WA Suite Number: 389 Floor: Tenant Name: Xf I n Ity New Tenant? ❑ - Yes J - No Property Owner's Name: Mailing Address: City State Zip CONTACT PERSON -if there are questions about the submittal. Name: Matt Carlman Day Telephone: 253-951-6005 Company Name: Fire Systems West, Inc. Mailing Address: 206 Frontage Road North, Suite C, Pacific, WA 98047 MattC@Firesystemswest.com City State Zip E-mail Address: Fax Number: 253-735-0115 Total number of new/relocated devices or sprinkler heads: Demo 3 devices, Add 8 Devices Valuation of Project (contractor's bid price): $ 4500 Scope of Work (please provide detailed information): Fire Systems West will demo 3 existing notification devices. Fire Systems West will be adding 8 new notification devices. PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Fire Marshal to comply with current fee schedules. Expiration of Plan Review -Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The Fire Marshal is authorized to grant, in writing, one or more extensions of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OR WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW E R THORIZED AGENT: att Signature: Date: 9/18/2015 Carlman Print Name: Day Telephone: 253-951-6005 Plan Permit App.doc 1/2/13 ITU FP Form 8 Battery Calculations for Panel: P2: EX Part No:5700 - INTELLIKNIGHT, FACP, 2 PROGRAMMABLE OUTPUTS Job number: 2-14-299028 Job name: COHO BUSINESS PARK Address 1: 2525 INTER AVE Address 2: PUYALLUP, WA 98373 Phone: (253)833-1248 Fax: (253)735-0113 Designing engineer: MATT CARLMAN Job Site: COHO BUSINESS PARK Authority having jurisdiction: CITY OF PUYALLUP Part No. Qty. Description Standby Total Standby Alarm Total Alarm FAX: 5700 Panel Equipment P2R P2R 20.4V EX 57008 1 MAIN CARD 200,0000mA 200.0000mA 325.0000mA 325.0000mA 2 SCR STROBE, 2 WIRE, M -C, RED, CEILING, 15CD Total Panel Stby 200.0000mA Total Panel Alarm 325.0000mA 3 SCR Peripheral Devices 10'-0 66.0000mA 20.1755V (0.0349V) PC2R 2 HORN/STROBE, 2 WIRE, M -C, RED, CEILING (Notification) 0.0000mA 0.0000mA 176.0000mA 352.0000mA PC2R 3 HORN/STROBE, 2 WIRE, M -C, RED, CEILING (Notification) 0.0000mA 0,0000mA 107.0000mA 321,0000mA SCR 3 STROBE, 2 WIRE, M -C, RED, CEILING (Notification) 0.0000mA 0.0000mA 66.0000mA 198.0000mA EOL 1 END OF LINE RESISTOR (Notification) 0.0000mA 0.0000mA 0.0000mA 0.0000mA 8 PC2R HORN/STROBE, 2 WIRE, M -C, RED, CEILING, 30CD Total Peripheral Stby 0,0000mA Total Periph Alarm 871.0000mA 8 EOL END OF LINE RESISTOR 3'-0 0.0000mA 19,9073V (OV) Total Standby Amps 200.0000mA Total Alarm Amps 1196.0000mA Standby time: 24 Hrs 4.8Ah Alarm time: 5 Min 0.lAh Battery requirement: 4.9Ah Compensation Factors - Standby: 1.2 Alarm: 1.2 Requirement with compensation: 5.88Ah Circuit Calculations Panel: P2 Card: 01 Circuit:SIG2 CircuitName: SIG2 Circuit Type: Notification Terminal Voltage: 20.4V:DC Amperage: 3.0000A Cable: 14/2 SOL JKT FPLP 1M RL RED #14 Calculations based on Running Total Length. Design Criteria: Ambient temperature: 167°F Max. operating voltage drop: 10% Device Part No Appliance Desc Distance Current Voltage Voltage Drop FAX: 5700 Panel P2R P2R 20.4V EX 1 PC2R HORN/STROBE, 2 WIRE, M -C, RED, CEILING, 30CD 26'-O 107.0000mA 20.2868V (0.1132V) 2 SCR STROBE, 2 WIRE, M -C, RED, CEILING, 15CD 20'-O 66.0000mA 20.2104V (0.0764V) 3 SCR STROBE, 2 WIRE, M -C, RED, CEILING, 15CD 10'-0 66.0000mA 20.1755V (0.0349V) 4 PC2R HORN/STROBE, 2 WIRE, M -C, RED, CEILING, 75CD 34'-0 176.0000mA 20.068V (0.1074V) 5 PC2R HORN/STROBE, 2 WIRE, M -C, RED, CEILING, 75CD 33'-0 176.0000mA 19.9928V (0,0752V) 6 PC2R HORN/STROBE, 2 WIRE, M -C, RED, CEILING, 30CD 34'-0 107.0000mA 19,9452V (0.0476V) 7 SCR STROBE, 2 WIRE, M -C, RED, CEILING, 15CD 32'-O 66.0000mA 19.9175V (0.0277V) 8 PC2R HORN/STROBE, 2 WIRE, M -C, RED, CEILING, 30CD 19'-0 107.0000mA 19.9073V (0,0102V) 8 EOL END OF LINE RESISTOR 3'-0 0.0000mA 19,9073V (OV) 211'-0 871.0000mA Total Current: 871.0000mA (Total VDrop Percent:2.41%) Total Voltage Drop : 0.4927V ❑ Without Comments As Noted in Re: O Per The Attached Letter These plans have been reviewed by The Tukwila Fire Prevention Bureau for conformance with current City standards. Acceptance is subject to errors and omissions which do not authorize violations or adopted standards and ordinances. The responsibility for the adequacy of design rests totally with the designer. Additions, deletions or revisions to these drawings after this date will void this acceptance and will require a resubmittal of revised drawings for subsequent approval. Final acceptance Is subject to field test and Inspection by The Tukwila Fire Prevention Bureau. i1 Date:_ g E'h5V,c_ INA cow a ` rvl l .51 -44 -muss. i ti3Se.fleJ k- (4'L 'e tc, 4-s . ss,14. e r+lr.l.< i' c,d, o�t,f . q,S o.c I "Mr- P TUKWILA FIRE DEPARTMENT P: an call 2D5-575-4407 and Give hi- Fire. Permit No. and exact aness jth shut- down or t est.xu,Lrcn approval. NOTICE completed, sgned, Tukwila Fire Department Pre-test Certificate must be presented to the Inspector prior to r .:'mmencernegt of Acceptance Testing of any Fire Alarm and DD(.- ectlon Systems. Failure of test will result in a Re -inspection Fee and t-ermination of the tes ir,cj EGL 4.7K f2 30CD 1 15CD 30CD 75CD ti Fire Alarm Symbol Legend SYMBOL DESCRIPTION PART NUMBER MODEL QUANTITY, USER TEXT UL FM FAX: 30 CD HORN/STROBE, 2 WIRE, M -C, RED, WALL P2R P2R 1 EX S4011 3023572 0 HORN/STROBE, 2 WIRE, M -C, RED, CEILING PC2R PC2R 3 EX 84012 3023572 75CD HORN/STROBE, 2 WIRE, M -C, RED, CEILING PC2R PC2R 2 S4012 3023572 Q30CD HORN/STROBE, 2 WIRE, M -C, RED, CEILING PC2R PC2R 3 84012 3023572 0 15CD STROBE, 2 WIRE, M -C, RED, CEILING SCR SCR 3 55512 3023572 En EOL 4.7K .l END OF LINE RESISTOR EOL EOL 1 tNTELLIKNtGHT, FACP, 2 PROGRAMMABLE OUTPUTS 5700 5700XL 1 EX S1383 FACP 75C0 15CD Cry 15CD y 1 V1 30CD a..%C P2 Area 0 , • • »emmineIr • • • IIIMMIN11111111111.111111111111 • 11111111111•11111 • IMMINIMINItiI • 11111111111111111111111MNINIMIN • 1111MIIIIIMINIMINIIII • ♦ • iiiiiiIMINNImilmmum • iiiiiimememin GENERAL NOTES 1 SCOPE OF WORK 1. FACTORY RECOMMENDED MINIMUM WIRING SIZES, TYPE AND CONSTRUCTION AS NOTED ON THE DRAWINGS MUST BE STRICTLY FOLLOWED. ANYONE WISHING TO MAKE CHANGES WILL DO SO AT THERE OWN RISK!! 2. THE CIRCUIT ROUTING AND WIRING COUNTS ON THE FLOOR PLAN DRAWINGS ARE SHOWN DIAGRAMMATIC BASED ON CONTINUOUS AND SHORTEST POSSIBLE ROUTING FROM THE CONTROL PANEL AND BETWEEN CONNECTED FIELD DEVICES WITH NO PHYSICAL OBSTRUCTIONS. THE WIRING OR CIRCUIT COUNTS (IF SHOWN) ARE PROVIDED AS A CONVENIENCE ONLY AND AS MEANS TO HASTEN INSTALLATION OR TO DETERMINE WIRING ROUTS. 3. WIRE SHOWN IN THIS DRAWING SET 15 PERMITTED IN RACEWAYS LEADING TO FIRE PROTECTION EQUIPMENT. OTHER WIRE SHALL NOT BE PERMITTED. 4. FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE LATEST U.L., N.E.C., N.F.P.A., W.A.C., AND OTHER STANDARDS AS APPLICABLE TO THE CITY STANDARDS. 5. WHEN NECESSARY, DUE TO CHANGING DESIGN REQUIREMENTS, FACTORY AVAILABILITY, ETC. FIRE SYSTEMS WEST RESERVES THE RIGHT TO SUBSTITUTE EQUIPMENT HEREIN MENTIONED OR SPECIFIED, WITH EQUIPMENT OF EQUAL OR BETTER QUALITY, FUNCTION AND DESIGN. 6. PARALLEL BRANCHING OF WIRE TO ALL NOTIFICATION APPLIANCE CIRCUITS SHALL NOT BE PERMITTED. 7. PARALLEL BRANCHING OF WIRE TO ANALOG INITIATING DEVICE CIRCUITS IS PERMISSIBLE. 8. THIS SPACE IS EQUIPPED WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM. 9. FIRE SYSTEMS WEST ADDING AND/OR RELOCATING FIRE ALARM DEVICES FOR TENANT IMPROVEMENTS. FIRE ALARM SYSTEM INFORMATION INSTALLERISUPPLIER SITE CONTACT: XFINITY DESIGNISUPPLIER: FIRE SYSTEMS WEST, INC. 301 STANDER BOULEVARD, SUITE 585106 FRONTAGE ROAD NORTH, STI TUKWILA, WA 98188 PACIFIC, WASHINGTON 98047 PHONE: PHONE: (253) 833.1248 FAX: FAX: (253) 735-0113 WA ST LICENSE: FIRESWI140B1 WAST LICENSE: FIRESWI055LW DESIGNER MATT CARLMAN FIRE SYSTEMS WEST, INC 206 FRONTAGE ROAD NORTH, STE PACIFIC, WASHINGTON 98047 PHONE: (253) 833-1248 FAX: (253) 735-0113 IFSAC #: 713543 09-6=110 X FOR FIRE DEPARTMENT USE ONLY A 1412 FPLP B 1612 FPLP EX EXISTING LOCATION WP WEATHER PROOF N NEW DEVICE R RELOCATE •$TROPE CbV RAGE AREA SHALL BE DEFINED h 10 FT. CLG. HT. 20 FT. CLG. HT. 30 FT. CLG. HT. 15 cd off' I,c = 30 cd=40'x c - 95cd=50'40' 110ed;50'x50' 115ed=50'x50' ii tI e Ct r^ae,:ake fa; fNNItif Yrec 5utte5 by - I (dlGn I fotr{ Sqntge .. u; vie, • VICINITY MAP SCALE: N.Y.S. 5: 01 Strand r 01v ru C AREA OF WORK urr.,.rt ac r'liF sc� hank .19 Roltar rrre PAID SEP 18 2015 Fax (253) 735-0113 x 0 J 0 m 0 w 0 ISSUED_ FOR REVIEW 1-- z 0 0 w z -J 1- 0 z a 0 0I0 0 x u? uer w w x w z w x w J w 0 0 2 cc tV Lu_ W ('3 w a a NW ..J 0 w STEM SENSOR rn 0 0 z z � � M LU LUN c:3 w GAMEWELL FCI GAMEWELL FCI GAMEWELL FCI w CEILING HORN STROBE WALL HORN STROBE SMOKE SENSORS ct0 z w rn w MINI HORNS a Epe C7 M LU -� © a • W• Et 0 im© 1- Q. < W iii c>ClC 0 0 Wcc) M rn co M W 0) M co J pp 0 � co cn z (1) ca X M 4 N LC) CO rn 9 LL J XFINITY 1 rrte,,. MI RCALE: ?!4"3.0r'1+ 6' 10' FIRE ALARM PLAN GENERAL NOTES 1 SCOPE OF WORK 1. FACTORY RECOMMENDED MINIMUM WIRING SIZES, TYPE AND CONSTRUCTION AS NOTED ON THE DRAWINGS MUST BE STRICTLY FOLLOWED. ANYONE WISHING TO MAKE CHANGES WILL DO SO AT THERE OWN RISK!! 2. THE CIRCUIT ROUTING AND WIRING COUNTS ON THE FLOOR PLAN DRAWINGS ARE SHOWN DIAGRAMMATIC BASED ON CONTINUOUS AND SHORTEST POSSIBLE ROUTING FROM THE CONTROL PANEL AND BETWEEN CONNECTED HELD DEVICES WITH NO PHYSICAL OBSTRUCTIONS. THE WIRING OR CIRCUIT COUNTS (IF SHOWN) ARE PROVIDED AS A CONVENIENCE ONLY AND AS MEANS TO HASTEN INSTALLATION OR TO DETERMINE WIRING ROUTS. 3. WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS LEADING TO FIRE PROTECTION EQUIPMENT. OTHER WIRE SHALL NOT BE PERMITTED. 4. FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE LATEST U.L., N.E.C., N.F.P.A., W.A.C., AND OTHER STANDARDS AS APPLICABLE TO THE CITY STANDARDS. 5. WHEN NECESSARY, DUE TO CHANGING DESIGN REQUIREMENTS, FACTORY AVAILABILITY, ETC. FIRE SYSTEMS WEST RESERVES THE RIGHT TO SUBSTITUTE EQUIPMENT HEREIN MENTIONED OR SPECIFIED, WITH EQUIPMENT OF EQUAL OR BETTER QUALITY, FUNCTION AND DESIGN. 6. PARALLEL BRANCHING OF WIRE TO ALL NOTIFICATION APPLIANCE CIRCUITS SHALL NOT BE PERMITTED. 7. PARALLEL BRANCHING OF WIRE TO ANALOG INITIATING DEVICE CIRCUITS IS PERMISSIBLE. 8. THIS SPACE IS EQUIPPED WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM. 9. FIRE SYSTEMS WEST ADDING ANDIOR RELOCATING FIRE ALARM DEVICES FOR TENANT IMPROVEMENTS. FIRE ALARM SYSTEM INFORMATION INSTALLER/SUPPLIER SITE CONTA T: XFINITY DESIGN/SUPPLIER: FIRE SYSTEMS WEST, INC. 301 STANDER BOULEVARD, SUITE ; 89206 FRONTAGE ROAD NORTH, STI TUKWILA, WA 98188 PACIFIC, WASHINGTON 98047 PHONE: PHONE: (253) 833-1248 FAX: FAX: (253) 735-0113 WA ST LICENSE: FIRESWI140B1 WA ST LICENSE: FIRESWI055LW DESIGNER MATT CARLMAN FIRE SYSTEMS WEST, INC 6 FRONTAGE ROAD NORTH, STE PACIFIC, WASHINGTON 98047 PHONE: (253) 833-1248 FAX: (253) 735.0.113 FSAC #: 713543 09-B-110 X 4 OR FIRE DEPARTMENT USE ONLY A 1412 FPLP B 1812 FPLP EX EXISTING LOCATION WP WEATHER PROOF N NEW DEVICE R RELOCATE .STROBE COVERAGE AREA SHALL BE DEFINED A 10 FT...9.q. HT. 20 FT. CLO. HT. 30 FT. C3L�O HT. 7 cd = 2340' x30' 9g cd - 90'x30' 19 Cd—:Iggd 00'x4' 95 cd =50'x50' 110 cd = 50'x50' 1'15 50'x50' 5: C AREA OF WORK 301 &ttxnd t i!!vd . Suc<rc ,t, 413 Cnsst tank 5 �1 IYw r Trr<. Oardr!<1me Suites by ftoton ttattl SeatlIr. 77. w,ru<vdt.4 dude too< ti VICINITY MAP SCALE: N.T.S. U W tt"> CZ WA ECL# FIRE W J U J a. 0 w CO CO 0 0) ISSUED_FOR_REVIEW 0 z NEW DEVICE COU h - z or Cs Co 0 0 0 0 0) u_ —J w 0 n,. 0) w a SYSTEM SENSOR CEILING HORN STROBE cZ N 0 w N coti m 0 z 0 x —J N O Lu x Cf 0 0)) Lu m O w Q w x a ce 0 a w C/7 w w w w 0 0, GAMEWELL FCI w W0 ,J J C, C> Cr) W F -- CN Wo co OC a © _ W ± 0)2 • mom - W W C� © VAC W 0 W c� BEL 503-348-9949 ON-SITE CONTACT: KYLE HE Lu w C C L" In = 1— E U. W< < HEAT SENSORS MINI HORNS OrE CN LL. LU Ch FILE:Xfiniti Fire Alarm Plan. cad DATE:09/17/15 TIME:17:31:31 --