Loading...
HomeMy WebLinkAboutPermit D18-0001 - KEURIG GREEN MOUNTAIN - INTERIOR TENANT IMPROVEMENTSKEURIG GREEN MOUNTAIN 7100 FORT DENT WAY D18-0001 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 2954900440 7100 FORT DENT WAY DEVELOPMENT PERMIT Project Name: KEURIG GREEN MOUNTAIN Permit Number: D18-0001 Issue Date: 1/24/2018 Permit Expires On: 7/23/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: JOHN C RADOVICH DEV CO 2835 82ND AV SE #S-1, MERCER ISLAND, WA, 98040 LINDA DUCEY 1200 FIFTH AVE, STE 1300 , SEATTLE, WA, 98101 Phone: (206) 408-8500 D P INC GENERAL CONTRACTORS Phone: (206) 361-2989 19936 BALLINGER WAY NE , SEATTLE, WA, 98155 DPINCGC066BU Expiration Date: 1/31/2020 JOHN C RADOVICH DEV CO Address: 2835 82ND AV SE #S-1, MERCER ISLAND, WA, 98040 DESCRIPTION OF WORK: INTERIOR TENANT IMPROVEMENTS INTO AN EXPANSION SPACE TO ANY EXISTING OFFICE SUITE ON THE FIRST FLOOR, SUITE #160, FOR OFFICE USE. TO INCLUDE DEMOLITION, NEW CONSTRUCTION OF PARTITIONS, NEW DOORS AND RELITES, NEW CASEWORK, EXISTING LIGHTING RELOCATED WITH SOME NEW FIXTURES. NO STRUCTURAL WORK AND NO ALTERATIONS TO THE BUILDING CORE. Project Valuation: $25,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $1,010.66 Occupancy per IBC: B Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit d agree to the conditions attached to this permit. Signature: j Print Name: UGv-vt Date: 2 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 5: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterally braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 16: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 13: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 14: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 15: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 17: Maintain fire extinguisher coverage throughout. 18: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1010.1.9) 19: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 20: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 21: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1010.1.9.1) 25: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 23: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) r1 22: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 26: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2437. 28: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 27: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 29: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 30: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. 24: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 31: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 32: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING 0502 LATH/GYPSUM BOARD 0406 SUSPENDED CEILING CITY OF TUKiA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. 1)( D- 000 r Project No. (� Date Application Accepted: 1-3-I 5 Date Application Expires: 7 3-1 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 2954900440 Site Address: 7100 Fort Dent Way Tenant Name: Keurig Green Mountain Suite Number: 160 Floor: 1st floor PROPERTY OWNER Name: John C. Radovich Development Co. Address: 2385 82nd Ave. SE, suite 300 Cit': Mercer Island State: WA Zip: 98040 CONTACT PERSON — person receiving all project communication Name: Linda Ducey Address: 19936 Ballinger Way NE Address: 1200 Fifth Ave., suite 1300 Phone: (206) 361-2989 Fax: City: Seattle State: WA Zip: 98101 Phone: (206) 408-8518 Fax: City: Seattle State: WA Email: lducey@nelsononline.com Phone: (206) 408-8500 Fax: GENERAL CONTRACTOR INFORMATION Company Name: DP Inc - General Contrators Address: 19936 Ballinger Way NE City: Shoreline State: WA Zip: 98155 Phone: (206) 361-2989 Fax: Contr Reg No.: DPINCGC066BU Exp Date: 01/31/2018 Tukwila Business License No.: BUS -0994280 1-1: Applications Forms -Applications On Line 2011 Applications Permit Application Revised - 3-9-I I docx Revised: August 2011 bh New Tenant: ❑ Yes ..No ARCHITECT OF RECORD Name: Company Name: NELSON Company Name: Architect Name: Mark Evans Aryk Address: 1200 Fifth Ave.., suite '1300 City: Seattle State: WA Zip: 98101 Phone: (206) 408-8500 Fax: Email: mevans@nelsononline.com State: ENGINEER OF RECORD Name: Company Name: \ J City: IL ,�1 State: 1 Zip:C� Aryk Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address:.• 4424,..0V p .6-1. ✓ E, 1.•d't"�-c� \ J City: IL ,�1 State: 1 Zip:C� Aryk Page 1 of 4 1 BUILDING PERMIT INFORMATIOa.;206-431-3670 Valuation of Project (contractor's bid price): $ 25,000 Describe the scope of work (please provide detailed information): Interior tenant improvements into an expansion space to any existing office suite on the first floor, suite #160, for office use to include demolition, new construction of partitions, new doors and relites, new casework, existing lighting relocated with some new fixtures. No structural work and no alterations to the building core. Existing Building Valuation: $ Will there be new rack storage? ❑ Yes VI.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes Z No If "yes", explain: FIRE PROTECTION/FIAZARDOUS MATERIALS: Z Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8-1/2 " x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: Applications Forms -Applications On Line 2011 Applications Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC lst Floor 726 0 0 V -B sprinkler B -office rd Floor 0 3rd Floor 0 Floors thru 0 Basement 0 Accessory Structure* 0 Attached Garage 0 Detached Garage 0 Attached Carport 0 Detached Carport 0 Covered Deck 0 Uncovered Deck 0 PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes Z No If "yes", explain: FIRE PROTECTION/FIAZARDOUS MATERIALS: Z Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8-1/2 " x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: Applications Forms -Applications On Line 2011 Applications Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR UTHO IZED AGENT: Signature: c. �1. V -�'�- 7 Date: 12/20/2017 g ��i Print Name: Linda Ducey Mailing Address: 1200 Fifth Ave. H. Applications Forms -Applications On Line 201 I Applications Permit Application Revised - R -9-I I.docx Revised: August 2_011 bh Day Telephone: (206) 267-6061 Seattle WA 98101 City State Zip Page 4 of 4 Cash Register Receipt City of Tukwila Receipt Number DESCRIPTIONS 1 ACCOUNT I QUANTITY PermitTRAK PAID $1,010.66 D18-0001 Address: 7100 FORT DENT WAY Apn: 2954900440 $1,010.66 DEVELOPMENT $981.07 PERMIT FEE R000.322.100.00.00 0.00 $591.86 PLAN CHECK FEE R000.345.830.00.00 0.00 $384.71 WASHINGTON STATE SURCHARGE 8640.237.114 0.00 $4.50 TECHNOLOGY FEE $29.59 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R13146 R000.322.900.04.00 0.00 *: $29.59 $1,010.66 Date Paid: Wednesday, January 03, 2018 Paid By: DP INC GENERAL CONTRACTORS Pay Method: CHECK 097173 Printed: Wednesday, January 03, 2018 2:07 PM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431-3670 DT -I) Iry 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: '/co DR/7- It* Date Called: Special Instructions: ea ar c.. Date Wanted: '3.-9-0 m. P• Requester: JOP Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: 32-' REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit Pt -cc 1 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pr ect: URU6- GAN M.WiTiNiki Type of Inspection: SO.SSPX4.047i CretV/46u Address: 7/63 etiArikisir Date Called: Special Instructions: Date Wanted: a-2_62 -/ E CZ) p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: srvsp. .� /Z. -1/W- Inspector: f5 Date: ^-2(p e/ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: krliR&- 6REgti 6140- Irmj/y Type of Inspection: fRA-PirN,&- Address: �* 7� !, D . 1 wily Date Called: Special Instructions: Date Wanted:/ 'P / 2'-/E a• a. p•m• Requester: _ Phone No: 2 —?76 -- 1ry. , Approved per applicable codes. Corrections required prior to approval. COMMENTS: wf ki,- fi 3 -r '/NC Inspector: Date: / _ 2 f -/& REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit U/ b --CO/ / 5- 0-467 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:�J � e ---e( -/ 6j///4 Sprinklers: Ya S Date: Type of Inspection: - ra zi . i —. 17,l/ r Address: Suite #: -7/00 ijy ��` SZ Contact Person: Special Instructions: Pre -Fire: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 4%g- #pg "" 3 //t/S'e e -A:7 ,& p( Sod/ Sprinklers: Ya S Date: — // gyri' et'f/46-, S /7/55,--e ,7 C ,4/ — ,'/VS D /C 7Z �- vet"- Pre -Fire: Permits: _ ii..;, -e X-/ 44 -- ,4J 2 GP --t.. ecW 4 eft-' / o4 i 64 vim,. — n;#‹e/ 4,v 4 7 — rtsS -- - /0`1'S(&(7 -e e 01 Arid," ,--..-_e 4xA /5 ..-0316-ofzr Needs Shift Inspection: t") ° Sprinklers: Ya S Date: Fire Alarm: VL'S Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: vim,. Inspector: .-yam 573 Date: y/9//8 Hrs.: Vein, $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: l�(4 67/ +44. Type of Inspection: ,� C:vrTh Hood & Duct: Address:�-- Suite #: (©d yr Qr '(6G Contact Person: L �- ,i1 Special Instructions: imp Phone No.: rJ 6)r Z 14r14/14 CrV Approved per applicable codes. ?� Corrections ections required prior to approval. COMMENTS: Sprinklers: L#" `7 Fire Alarm:_ Hood & Duct: Monitor: J Pre -Fire: Permits: Occupancy Type: imp 2 rJ 6)r Z 14r14/14 CrV /2IV r "7-7) G t oS 6 7 04 /77") — CE-'Tc�'L GF- OpeN 5ie & fit b (2) of 1,/,,,J 5- Ccit,i7-6a- 6,i/i_55;?-7-?_r-- ? r Qk- 0k- 7 cGvt-- - /1-(zt')ls A/6 7--- - G re ---6 A Needs Shift Inspection: '-> Sprinklers: L#" `7 Fire Alarm:_ Hood & Duct: Monitor: J Pre -Fire: Permits: Occupancy Type: Inspector: 'f"77'7 5-4--- Date: 4,2-Mit t Hrs.: 1 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0001 DATE: 01/03/18 PROJECT NAME: KEURIG GREEN MOUNTAIN SITE ADDRESS: 7100 FORT DENT WAY - SUITE ??? X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: ift0 C Building D'vision IstW I \t.\ 1(6 Public Works AAwc Fire Prevention Structural May AYA-- HriS Planning Division 1011 nPermit Coordinator PRELIMINARY REVIEW: DATE: 01/04/18 Not Applicable n Structural Review Required (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Notation: DUE DATE: 02/01/18 Approved with Conditions [8( Denied (ie: Zoning Issues) PAt- •PiThe‘Pi-- n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire D Ping ❑ PW 0 Staff Initials: 12/18/2013 D P INC GENERAL CONTRACTOC Horne Espanol Contact Safety & Health Claims & Insurance Washington State Department of k% Labor & Industries Search L&I Page 1 of 2 A -Z index Help My L&1 Workplace Rights Trades & Licensing D P INC GENERAL CONTRACTORS Owner or tradesperson Principals DODSON, WILLIAM, PRESIDENT Doing business as D P INC GENERAL CONTRACTORS WA UBI No. 601 515 833 19936 BALLINGER WAY NE SEATTLE, WA 98155 206-361-2989 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ..........................................................._.. Meets current requirements. License specialties GENERAL License no. DPINCGC066BU Effective — expiration 01/31/1994— 01/31/2020 Bond Merchants Bonding Co (Mutual) Bond account no. WA28622 $12,000.00 Received by L&I Effective date 12/27/2012 01/31/2013 Expiration date Until Canceled Bond history Insurance Continental Western Ins Co $1,000,000.00 Policy no. CPA6015605 Received by L&I Effective date 08/10/2017 09/15/2016 Expiration date 09/15/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts .......... ............. No L&. tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601515833&LIC=DPINCGC066BU&SAW= 1/24/2018 D P INC GENERAL CONTRACTO— S No license violations during the previous 6 year period. License Violations Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 578,236-01 ............................... Doing business as D P INC Estimated workers reported Quarter 4 of Year 2017 "76 to 100 Workers" L&I account contact T5 / JAVIER PAREDES (360)902-4639 - Email: PAJB235@Ini.wa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes .................................................... No strikes have been issued against this contractor. Contractors not allowed to bid ............................................................................................ No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 03/05/2014 Inspection no. 316958065 Location 625 Andover Park W. Tukwila, WA 98188 Violations Page 2 of 2 J Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.Ini.wa.gov/verify/Detail.aspx?UBI=601515833&LIC=DPINCGC066BU&SAW= 1/24/2018 Nelco Architecture, Inc. a licensed affiliate of Nelson Worldwide, Inc. 1200 Fifth Avenue, Suite 1300 Seattle, WA 98101 Phone: (206) 408-8500 Fax: (206) 223-4990 Consultant: Description: No: By: Date: PERMIT SET NG, EB 11/10/17 FORT DENT III 7100 FORT DENT -WAY TUKWILA, WA 98168 Client: KEURIG GREEN MOUNTAIN 7100 FORT DENT WAY, SUITE 160 TUKWILA, WA 98168 Project Title & Address: COVER SHEET Sheet Title: 8459 REG :m. . c II I r:C7" • MARK DOUGLAS EVENS SI IL 01NAYIHNOt N 11 14 - Seal: Proj. No: MS.01614.00 Drawn By: NG Project Manager: LD Designer: EB Reviewed By: LD Approved By: LD Al SCOPE OF WORK: TENANT IMPROVEMENT TO EXPAND EXISTING SUITE IN AN EXISTING 2 -STORY OFFICE BUILDING FOR OFFICE USE TO INCLUDE: • DEMOLITION OF INTERIOR PARTITIONS, DOOR & RELITE • CONSTRUCTION OF INTERIOR PARTITIONS, DOORS, RELITES &CASEWORK • NEW PAINT AND FLOORING IN AREAS OF SUITE • INSTALLATION OF RELOCATED LIGHT FIXTURES SITE ADDRESS: FORT DENT III 7100 FORT DENT WAY, SUITE 150, TUKWILA, WA 98168 PARCEL NUMBER: 295490-0440 LEGAL DESCRIPTION: GUNDRAKERS INTERURBAN ADD PARCEL 2 LESS GEG MOST WLY CORNER OF K55.63 'v i t4�T gYt �,� PARCEL 1 TH N 63-35-49 E 237.32 FT TH S 26-24-11 E 227:32 FT TO COMMON COR BTW PARCELS 1 & 2 TH N 63-35-49 E 252.25 FT TH N 26-24-11 W 77.65 FT TH N 56-15-11 W 234.09 FT TH N 31-12-43 W 82.39 FT TO INTSN WITH NWLY LN OF PARCEL 2 TH S 58-47-17 E 102.77 FT TH S 55-39-53 W 63.16 FT TH S 48-39-58 W FT TH S 39-21-15 W 88.24 FT TH S 30-04-58 W 85.21 FT TO MOST WLY COR OF PARCEL 2 TH S 37-36-40 E 20.92 FT TO POB - OF CITY OF TUKWILA SHORT PLAT NO 79 -7 -SS RECORDING NO 7908210370 SD SHORT PLAT BEING A POR OF GUNDAKERS INTERURBAN ADD IN SW 1/4 OF SEC 24-23-04 --- AS PER CITY OF TUKWILA BDRY LINE ADJ NO 90-2-BLA RECORDING NO 9008151101 ZONING: RCM TYPE OF CONSTRUCTION: V -B, FULLY SPRINKLERED OCCUPANCY: GROUP B (OFFICE) TENANT IMPROVEMENT AREA OF SUITE: ± 2,886 SF AREA OF WORK: ± 726 SF FoRT DENT 111... 1 sT FLooR APPLICABLE CODES: 2015 INTERNATIONAL BUILDING CODE (IBC) 7100 F 0 RT DENT TUK\NILA, \JVASHINGTON SUITE 160 98168 2015 INTERNATIONAL FIRE CODE (IFC) 2015 INTERNATIONAL PLUMBING CODE (IPC) 2015 INTERNATIONAL MECHANICAL CODE (IMC) 2015 WASHINGTON STATE ENERGY CODE (WSEC) 2015 INTERNATIONAL FUEL AND GAS CODE (IFGC) ©(' NATIONAL ELECTRICAL CODE (NEC) 2009 ICC / ANSI A117.1 -ACCESSIBLE AND USABLE BUILDINGS & FACILITIES WASHINGTON INDOOR AIR QUALITY CODE TENANT KEURIG GREEN MOUNTAIN 7100 FORT DENT WAY, SUITE 160, TUKWILA, WA 98168 PHONE: NA !SEPARATE SEPARATE PERMIT 1-,EOUIRED FOR: t ' chanical EMAIL: Marc.Bard.@gmcr.com CONTACT: MARC BARD BUILDING JCR DEVELOPMENT COMPANY WdeCincal REPRESENTATIVE: 2835 82ND AVENUE SE, SUITE 81, MERCER ISLAND, WA 98040 rez adzis''' Ci 4 T+ c.r his i BUMMING DIRMCM PHONE: (206) 267-6060 EMAIL: RebeccaDavidson@jcrdevco.com CONTACT: REBECCA DAVIDSON ARCHITECT: NELSON 1200 5TH AVENUE, SUITE 1300, SEATTLE, WA 98101 1 I PROJECT TITLE E NA PHONE: (206) 408-8500 EMAIL: MEvans@nelsononline.com 1. COMPLY WITH ALL APPLICABLE CODES. CONTACT: MARK EVANS GENERAL CP INCORORATED FOOT 1. MECHANICAL, FIRE PROTECTION AND LIFE SAFETY ALTERATIONS AND CONSTRUCTION ARE BY 11. N.F.P.A. / I.F.C. APPROVED FIRE EXTINGUISHERS SHALL BE LOCATED WITHIN 75 FEET FROM ANY DEFERRED POINT ALONG THE PATH OF TENANT EGRESS OR AS REQUIRED BY THE LOCAL FIRE MARSHAL. 2. GENERAL CONTRACTOR SHALL VISIT THE JOB SITE AND VERIFY FIELD CONDITIONS PRIOR TO CONTRACTOR: 19936 BALLINGER WAY NE, SEATTLE, WA 98155 ACT ACOUSTICAL CEILING TILE LF LINEAL ADJ ADJACENT / ADJUSTABLE MAX MAXIMUM AFF ABOVE FINISH FLOOR MECH MECHANICAL ALT ALTERNATE MFR MANUFACTURER ALUM ALUMINUM MIN MINIMUM APPROX APPROXIMATELY MISC MISCELLANEOUS @ AT MTD MOUNTED BLDG BUILDING MTL METAL BLKG BLOCKING MW MICROWAVE OVEN BIS BUILDING STANDARD N NORTH / NEW CAB CABINET N/A NOT APPLICABLE CLR CLEAR/CLEARANCE NIC NOT IN CONTRACT CLG CEILING NO NUMBER CL CENTERLINE NOM NOMINAL COL COLUMN NTS NOT TO SCALE COMM COMMUNICATION OC ON CENTER COMP COMPOSITION OPNG OPENING OTHERS, UNDER SEPARATE PERMITS BY DESIGN BUILD CONTRACTORS - SUBMITTALS. 2. RE -BALANCE THE HVAC SYSTEM AND PROVIDE WRITTEN REPORT TO OWNER. 12. THE SPACE AROUND PIPES DUCTS ETC. PENETRATING FIRE RESISTANT CONSTRUCTION SHALL NOT EXCEED'/z" & SHALL BE PACKED SOLID WITH APPROVED FIRE SAVING MATERIAL & SEALED 3. CLEAN ALL DIFFUSERS & GRILLES. WITH METAL ESCUTCHEONS EACH SIDE AS REQUIRED BY CODE. 4. VERIFY LOCATION OF THERMOSTATS WITH OWNER AND NELSON PRIOR TO FINAL INSTALLATION. 13. MAINTAIN INTEGRITY OF RATED ASSEMBLIES AND REPAIR ANY DAMAGE TO SPRAY -APPLIED FIRE PROOFING. 5. ALL CONSTRUCTION WORK IS CONFINED TO THE BUILDING INTERIOR. CONTRACTOR SHALL PROVIDE BARRIERS OR SYSTEMS TO CONTAIN DUST, DIRT OR DEBRIS TO MINIMIZE INCONVENIENCE TO OTHER TENANTS WITHIN THE BUILDING. 6. CONSTRUCTION OPERATIONS SHALL NOT OBSTRUCT HALLWAYS, CORRIDORS, STAIRWAYS OR MEANS OF EGRESS FOR THE TENANTS OF THE BUILDING. 7. DO NOT DISRUPT HVAC, PLUMBING, ELECTRICAL OR FIRE PROTECTION SYSTEMS WITHOUT PRIOR AUTHORIZATION FROM OWNER. 8. THE CONSTRUCTION SITE SHALL BE LEFT CLEAN & ORDERLY AT THE END OF EACH WORK DAY. PURCHASING MATERIALS OR COMMENCING THE WORK. 3. REPORT ANY DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND DRAWINGS TO ARCHITECT BEFORE PROCEEDING WITH THE WORK. 4. VERIFY THE BUILDING STANDARDS (B/S) BEFORE PROCEEDING WITH THE WORK. 5. OBTAIN ALL REQUIRED PERMITS AND APPROVALS BEFORE PROCEEDING WITH THE WORK. 6. WALLS, PARTITIONS AND CEILINGS SHALL BE INDEPENDENTLY BRACED TO RESIST SEISMIC FORCES. 7. PROVIDE BLOCKING AT ALL WALL MOUNTED ITEMS. 8. ALIGN AND SHIM TRANSITIONS BETWEEN OLD AND NEW CONDITIONS. 9. LEVEL THE FLOOR. DEVIATIONS OF ± 112" WITHIN 10'-0" IS THE ACCEPTABLE LIMIT. PHONE: (206) 361-2989 EMAIL: vshadrin@dpi.com CONTACT: VASILY SHADRIN CONST CONSTRUCTION OPP OPPOSITE CONT CONTINUOUS ORIG ORIGINAL 9. NO ONE WILL OCCUPY THE AREA OF WORK OTHER THAN AUTHORIZED CONSTRUCTION _...""�"- 10. GENERAL CONTRACTOR TO REVIEW AND STAMP OR MARK REQUIRED SUBMITTALS AND SHOP DRAWINGS PRIOR TO SENDING COPIES TO TENANT FOR REVIEW AND COMMENT. 0 REVIEWED FOR CPT CARPET PERM PERMANENT PERSONNEL. _.. REVISIONS CODE COMPLIANCE APPROVED CT CERAMIC/CONCRETE TILE PL PLATE DIA DIAMETER PLAT PLASTIC LAMINATE DR DOOR PLYWD PLYWOOD DIM DIMENSION PR PAIR DW DISHWASHER PTN PARTITION DWG DRAWING R RADIUS / REMOVE / RELOCATE 10. THE GENERAL CONTRACTOR SHALL PROVIDE TEMPORARY CONSTRUCTION BARRIERS TO INHIBIT ACCESS BY NON -AUTHORIZED PERSONNEL AND AS REQUIRED BY O.S.H.A. STANDARDS TO PREVENT INJURIES OR ACCIDENTS. , No ChBnc�c:S shall bF mudP to the scope of tori: witho:.1 prior approval of 3 tlk, <<ila Building Division. t\ OTp 1-.v,aC^s Will require a new plan submittalA-7./. and may include additional plan review fees. � 11. THE BUILDING REPRESENTATIVE SHALL ESTABLISH WORKING TIME AND STANDARDS OF CONDUCT. 12. DO NOT SCALE DRAWINGS. 13. GENERAL CONTRACTOR SHALL COORDINATE ACTIVITIES OF ALL SUBCONTRACTORS, DELIVERY, ����� jt o of Tukvdi 1 E EXISTING / EAST RB RUBBER BASE AND STAGING OF MATERIALS. EA EACH REF REFRIGERATOR EAD EXIT ACCESS DOOR REFL'D REFLECTED REINF REINFORCING ELEC ELECTRIC ELEC'L ELECTRICAL REQ'D REQUIRED ELEV ELEVATION (VIEW) REV REVISION I REVERSE EQ EQUAL RM ROOM 2 MECHANICAL PLUMBING FIRE PROTECTION & LIFE SAFETY NOTES NTS 3 I GENERAL NOTES NA 4 PROJECT INFORMATION NA EXIST EXISTING RO ROUGH OPENING EXT EXTERIOR S SOUTH FIN FINISH SCHED SCHEDULE FLR FLOOR SC SOLID CORE FLUOR FLUORESCENT SECT SECTION , FMC FLOOR MATERIAL CHANGE SIM SIMILAR FR FIRE RATED SPEC SPECIFICATION FT FEET SQ SQUARE STD STANDARD FORT DENT PARK \�, GREEN RIVER ---_-- _��- _ -`---_ f` _ .:::::::::::.:::::::::::::::.:-:......;:::.--,_. �� .::::..:.... ::.:::::::::::::::...... :.:.: -- �'' __ A-1 COVER SHEET A-2LIFE SAFETY PLAN FURN FURNISH I FURNISHINGS GA GAUGE STL STEEL GALV GALVANIZED STOR STORAGE GD GARBAGE DISPOSAL SUSP SUSPENDED GL GLASS I GLAZING TEL TELEPHONE y41 u' 2 --✓ \ ,' , �I ;:FILE r , �.' s S �VA • ` `9::000rrroordOrsin(nd � 0• A-3 DEMOLITION PLAN, CONSTRUCTION PLAN & REFLECTEDCEILING PLAN . GWB GYPSUM WALL BOARD TSG TEMPERED SAFETY GLASS FORT DENT III , NER 1 FORT DENT 2' A-4 ELECTRICAL l COMMUNICATION PLAN HC HOLLOW CORE TYP TYPICAL yGREE FORT DENT WAY rj7100 ro T DENT s 4, 1Plan revi ;'rr c rcva?! is subjeceaomissions.A-5 HDW HARDWARE UNO UNLESS NOTED OTHERWISE HM HOLLOW METAL VCT VINYL COMPOSITE TILEBUILDING HT HEIGHT VERT VERTICAL c� cr ST EXISTING OFFICE �- ♦ �.��;��, / ����;�,.;;.. , •- •;� s t' ��' a\ Approvalof construction docunts doss not authorize theviolationoIanyadoptedcoance. FRAME DOOR &RELITE SCHEDULE ELEVATION &DETAILS �ECEIVE� HVAC HEATING, VENTILATING, W WEST W/ WITH IN NICH CONDITIONING W/0 WITHOUT �* y�FNT1 �S�Vp 11011 •'''''''''' 1 i ♦ : :. ��� /ice g 1 : �1 " Rece'r & I approved Field opy and conditions is acknowledged: � CITY OF TUKWILA JAN 03 2010 INCL INCLUDE WC WALLCOVERING .i1 / 1.1 I By: �^-- INSUL INSULATION WD WOOD --.-_ ;vn --/'. ��� 405 " i Date: IOW PERMIT INT INTERIOR`. RS pg. 4 4 CENTER MI s , q JT LL@TE BYINT LANDLORD AT TENANT'S o,.rn - - l FORT DENT III - - City of Tukwila EXPENSE roe 7100 FORT DENT WAYti `77 BUILDINGDIVISION _ tXIS 1 INV UftIGt • BUILDING NORTH NORTH IIIMINIMIIIMIIIMINIMP 5 1 ABBREVIATIONS NA 6 VICINITY MAP NA 7 SITE PLAN NA 8 NOT USED NA 9 SHEET INDEX NA Nelco Architecture, Inc. a licensed affiliate of Nelson Worldwide, Inc. 1200 Fifth Avenue, Suite 1300 Seattle, WA 98101 Phone: (206) 408-8500 Fax: (206) 223-4990 Consultant: Description: No: By: Date: PERMIT SET NG, EB 11/10/17 FORT DENT III 7100 FORT DENT -WAY TUKWILA, WA 98168 Client: KEURIG GREEN MOUNTAIN 7100 FORT DENT WAY, SUITE 160 TUKWILA, WA 98168 Project Title & Address: COVER SHEET Sheet Title: 8459 REG :m. . c II I r:C7" • MARK DOUGLAS EVENS SI IL 01NAYIHNOt N 11 14 - Seal: Proj. No: MS.01614.00 Drawn By: NG Project Manager: LD Designer: EB Reviewed By: LD Approved By: LD Al ALL DIMENSIONS AND CONDITIONS MUST BE CHECKED AND VERIFIED ON SITE BY THE CONTRACTOR AND SUB -CONTRACTORS PRIOR TO PERFORMING THE WORK. THE PROJECT MANAGER SHALL BE NOTIFIED IN WRITING OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. © NELSON WORLDWIDE, INC. 2017 ALL RIGHTS RESERVED Plot Date: 12/21/2017 1:16:32 PM Filename: J:\BLDGS\A-F\Fort Dent III\Keurig Green Mountain - 01\EXPANSION 2017\Working Drawings\(A-2) KEX-LS-01.dwg User: Nixon Golla Device: None PenTable: _NELSON-FULL.ctb FORT DENT BUILDING III EXISTING TWO (2) STORY OFFICE BUILDING BUILDING LOBBY EXPANSION AREA 726 SQUARE FEET LIFE SAFETY PLAN SCALE: 1/8" =1'-0" 0 5' 10' 20' EXCLUSIONS 30' NO CHANGE IN BUILDING AREA NO CORE / SHELL WORK NO STRUCTURAL WORK NO EXTERIOR WORK NO CHANGE OF USE OCCUPANT LOAD & EXITING PER IBC TABLE 1004.1.2: BUSINESS AREA (OFFICE) = 100 SF PER OCCUPANT PER IBC TABLE 1015.1: 0-49 OCCUPANT LOAD = ONE (1) EXIT REQUIRED 50-500 OCCUPANT LOAD = TWO (2) EXITS REQUIRED 726 SF @ 1:100 = 8 OCCUPANTS 1 EXIT REQUIRED, 2 EXIT PROVIDED COMMON PATH OF EGRESS TRAVEL PER IBC 1006.2.1: FOR GROUP B OCCUPANCY, MAX. LENGTH =100'-0" FOR BUILDINGS WITH SPRINKLER SYSTEM LONGEST COMMON PATH OF EGRESS TRAVEL = ± 52' PROJECT COMPLIES NORTH EXIT ACCESS TRAVEL DISTANCE PER IBC TABLE 1017.2: FOR GROUP B OCCUPANCY, MAX. TRAVEL DISTANCE = 300'-0" FOR BUILDINGS WITH SPRINKLER SYSTEM PROJECT COMPLIES bi� REVIEWED FOR CODE COMPLIANCE APPROVED 1 JAN 1.7 2018 city of Tukwila SING I 1SLO o00 1 RECEIVED CITY OF TUKWILA JAN 03 2018 PERMIT CENTER Nelco Architecture, Inc. a licensed affiliate of Nelson Worldwide, Inc. 1200 Fifth Avenue, Suite 1300 Seattle, WA 98101 Phone: (206) 408-8500 Fax: (206) 223-4990 Consultant: Description: No: By: Date: PERMIT SET NG, EB 11/10/17 FORT DENT III 7100 FORT DENT WAY TUKWILA, WA 98168 Client: KEURIG GREEN MOUNTAIN 7100 FORT DENT WAY, SUITE 160 TUKWILA, WA 98168 Project Title & Address: LIFE SAFETY PLAN • Sheet Title: 8459 $ #04. RK DOUGLAS S1AIli01'W'SIIINTON Seal: �? CMI1: /1 EVA �" Proj. No: MS.01614.00 Drawn By: NG Project Manager: LD Designer: EB Reviewed By: LD Approved By: LD A-2- ALL DIMENSIONS AND CONDITIONS MUST BE CHECKED AND VERIFIED ON SITE BY THE CONTRACTOR AND SUB -CONTRACTORS PRIOR TO PERFORMING THE WORK. THE PROJECT MANAGER SHALL BE NOTIFIED IN WRITING OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. © NELSON WORLDWIDE, INC. 2017 ALL RIGHTS RESERVED Plot Date: 12/21/2017 1:16:55 PM Filename: J:\BLDGS\A-F\Fort Dent III\Keurig Green Mountain - 01\EXPANSION 2017\Working Drawings\(A-3) KEX-DE-PL-CL-01.dwg User: Nixon Golla Device: None PenTable: _NELSON-FULL.ctb OPEN WORK AREA 100 EXISTING TENANT SUITE EXPANSION AREA DEMOLITION / CONSTRUCTION PLAN SCALE: 1/8" =1'-0" 0 5' 10' 20' 0 / / / /„.-////////-,/////,'„////'/".///////:// / / � / � � /// / // / '/ / '/ i 30' NORTH III MI NMI NMI 11111 //, / ' / � ///1/////// / ////// /// i, //////:////////:,/,/,:/-///',///,/ ,////////////7 ////, // i, // /// / / /// J/ , /// i' // ' „ 4 201 /' I I 103 r - I I I I I 102 1 N 413 111111111111116 I 11 X C 101 EXPANSION AREA j/ ////////,// 13////// r/ % // ;' 7/// ' / / %/// J' / / / / /////' / /// , ,/ EXISTING TENANT SUITE - ■ ■ - ■ 4 REFLECTED CEILING PLAN ?r SCALE: 1 /8" =1'-0" 0 5' 10' 20' 30' NORTH DEMOLITION / CONSTRUCTION LEGEND EXISTING BUILDING SHELL & CORE NOT TO BE ALTERED EXISTING CORRIDOR PARTITION TO REMAIN EXISTING BIS DEMISING PARTITION TO REMAIN _____= EXISTING CONSTRUCTION TO BE DEMOLISHED zzz /; rr I II kE jr-* c EXISTING FULL HEIGHT RELITE TO REMAIN R # NEW BIS FULL HEIGHT RELITE PER 9/A-5 SCHEDULE 1 1 ALIGN NEW BIS CORRIDOR PARTITION PER 8/A-5 DETAIL NEW BIS SOUND PARTITION PER 61A-5 DETAIL NEW BIS TENANT PARTITION PER 7/A-5 DETAIL NEW CASEWORK EXISTING DOOR TO REMAIN EXISTING DOOR TO BE REMOVED NEW B/S DOOR PER 9/A-5 SCHEDULE CI FEC FE 0 EXISTING FIRE EXTINGUISHER CABINET (FIRE EXTINGUISHER) CONSTRUCTION KEYNOTES CONTRACTOR TO PROVIDE AND INSTALL WHITE MELAMINE CLOSET SHELF AND COAT ROD. CONTRACTOR TO ALIGN NEW PARTITION TO EXISTING COLUMN. RELOCATE EXISTING FIRE EXTINGUISHER TO THIS LOCATION. CONTRACTOR TO REMOVE EXISTING ENTRY DOOR AND RELITE AND RETURN TO BUILDING INVENTORY. CONTRACTOR TO REMOVE EXISTING EMERGENCY LIGHTING AND RELOCATE TO OPEN WORK AREA #100. VERIFY LOCATION WITH FIRE DEPARTMENT OFFICIAL. CEILING LEGEND IEXISTING CEILING GRID AND TILES TO REMAIN tec EXISTING BIS 2'x4' RECESSED FLUORESCENT LIGHT FIXTURE TO REMAIN EXISTING BIS 2'x4' RECESSED FLUORESCENT LIGHT FIXTURE TO BE REMOVED. RELOCATED B/S 21x4' RECESSED FLUORESCENT LIGHT FIXTURE TO BE UPGRADED FOR EMERGENCY LIGHTING. LAYOUT SHOWN IS CONCEPTUAL ONLY EXISTING BIS ILLUMINATED EXIT SIGN (R = RELOCATED) NEW B/S LIGHT SWITCH EXISTING CEILING MOUNTED DUPLEX ELECTRICAL OUTLET AND BLANK PLATE LIGHTING CALCULATION EXISTING CEILING GRID, TILE AND FIXTURES TO REMAIN. EXISTING LIGHTING LAYOUT USES 9 FIXTURES. THE NEW LAYOUT RELOCATES 2 OF THE EXISTING FIXTURES. 2/9 x 100 = 22.22% WHICH IS LESS THAN THE 50% ALLOWABLE CHANGE PER 2015 WSEC LIGHTING ALTERATION EXCEPTION C503.6. EXISTING WATTAGE STAYS THE SAME. CEILING KEYNOTES REPAIR, CEILING GRID AND TILES IN THIS AREA TO MATCH EXISTING IN SUITE. DEMOLITION / CONSTRUCTION NOTES 1. REMOVE EXISTING FLOORING AND BASE IN EXPANSION AREA ONLY AND PREP FOR NEW CARPET TILE AND BASE. 2. A CLEAR PATH OF EGRESS TRAVEL SHALL REMAIN OPEN AT ALL TIMES DURING DEMOLITION. 3. DISRUPTION OF THE BUILDING FIRE ALARM, ELECTRICAL POWER, WATER, OR LIFE SAFETY SYSTEMS MUST BE COORDINATED WITH ALL GOVERNING AGENCIES AND THE BUILDING REPRESENTATIVE. 4. ALL DEBRIS SHALL BE REMOVED FROM THE DEMOLITION SITE DAILY. 5. ALL DEMOLITION SHALL BE PERFORMED IN ACCORDANCE WITH THE BUILDING REPRESENTATIVE'S RULES AND REGULATIONS WITH MINIMAL DISTURBANCE TO OTHER TENANTS. 6. CONTRACTOR SHALL PROVIDE DUST BARRIERS FOR PROTECTION OF EXISTING ADJACENT AREAS. ALL HVAC SYSTEMS ARE TO BE PROTECTED DURING DEMOLITION. 7. CONTRACTOR SHALL NOTIFY BUILDING REPRESENTATIVE AND NELSON OF ANY DEMOLITION WORK THAT IMPACTS THE STRUCTURAL INTEGRITY OF THE BUILDING. 8. GENERAL CONTRACTOR SHALL IMMEDIATELY REPORT ALL ACCIDENTS, ERRORS OR DEFECTS TO THE BUILDING REPRESENTATIVE. 9. PROVIDE DEMOLITION TO EXISTING WALLS, DOORS, CASEWORK, AND FLOORING AS REQUIRED. RECYCLING AND REUSE OF CONSTRUCTION MATERIALS IS HIGHLY ENCOURAGED WHERE APPROPRIATE. 10. INSTALL DOUBLE STUDS AT DOOR JAMBS AND HEADERS. 11. PROVIDE FIBER GLASS REINFORCED WATER RESISTANT GYPSUM BOARD IN AREAS SUSCEPTIBLE TO MOISTURE. 12. DIMENSIONS ARE FINISH SURFACE TO FINISH SURFACE, U.N.O. 13. REPORT ANY DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL FIELD CONDITIONS TO THE ARCHITECT. CEILING NOTES 1. CHECK FOR CONFLICTS BEFORE INSTALLING OR RELOCATING LIGHT FIXTURES. NOTIFY ARCHITECT OF ANY CONFLICT(S). 2. REPLACE DAMAGED CEILING TILES AND GRID AS NECESSARY TO BRING CEILING TO "LIKE NEW" CONDITION. 3. MAINTAIN EXISTING ONE FOOTCANDLE PER SQUARE FOOT AT EGRESS PATHWAY LIGHTING. 4. MAINTAIN 42" CLEAR SPACE IN FRONT OF THE PANEL SIDE OF ANY V.A.V. BOXES. 5. DAYLIGHT ZONE CONTROL: DAY LIGHTING AS DEFINED BY CODE SHALL BE PROVIDED WITH INDIVIDUAL CONTROLS, OR DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS PER SECTION C405.2.2.2 OF THE WASHINGTON STATE ENERGY CODE. 6. FIRE SPRINKLER INSTALLATION TO BE DESIGN -BUILD WITH DEFERRED PERMIT SUBMITTALS. 7. COMMISSIONING REQUIREMENTS: TEST LIGHTING CONTROLS TO ENSURE THAT THE SYSTEMS COMPLY WITH CODES. PROVIDE A WRITTEN REPORT OF TEST PROCEDURES AND RESULTS TO THE OWNER. USE OCCUPANCY SENSORS AS REQUIRED. 8. EXIT SIGNS ARE INDICATED ON THE REFLECTED CEILING PLAN. THEIR FINAL PLACEMENT IS TO BE COORDINATED IN THE FIELD WITH THE INSPECTOR. REVIEWED FOR CODE COMPLIANCE APPROVED JAN 1.7 ?018 City of Tukwila BUILD G-DIVMSLON RECEIVED CITY OF TUKWILA JAN 03 2010 PERMIT CENTER Nelco Architecture, Inc. a licensed affiliate of Nelson Worldwide, Inc. 1200 Fifth Avenue, Suite 1300 Seattle, WA 98101 Phone: (206) 408-8500 Fax: (206) 223-4990 Consultant: Description: No: By: Date: PERMIT SET NG, EB 11/10/17 FORT DENT III 7100 FORT DENT WAY TUKWILA, WA 98168 Client: KEURIG GREEN MOUNTAIN 7100 FORT DENT WAY, SUITE 160 TUKWILA, WA 98168 Project Title & Address: DEMOLITION, CONSTRUCTION & REFLECTED CEILING PLANS Sheet Title: '• 8459 AR(I II I L Y 1 A MARK DOUG" STATI: of WAS! IMO ION rio14.I* Seal: Proj. No: MS.01614.00 Drawn By: NG Project Manager: LD Designer: EB Reviewed By: LD Approved By: LD A-3 ALL DIMENSIONS AND CONDITIONS MUST BE CHECKED AND VERIFIED ON SITE BY THE CONTRACTOR AND SUB -CONTRACTORS PRIOR TO PERFORMING THE WORK. THE PROJECT MANAGER SHALL BE NOTIFIED IN WRITING OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. © NELSON WORLDWIDE, INC. 2017 ALL RIGHTS RESERVED Plot Date: 12/21/2017 1:18:03 PM Filename: J:\BLDGS\A-F\Fort Dent III\Keurig Green Mountain - 01\EXPANSION 2017\Working Drawings\(A-4) KEX-DE-PO-01.dwg User: Nixon Golla Device: None PenTable: _NELSON-FULL.ctb 0 i O \ II OE 103 1 ■n 102 / / //" / ' V / /7/ / / /// j/' % /'///,'/ / / / / // j / / / / FEC EXPANSION AREA / 101 100 As S. • / / / i' / / / /" ' } /`/ / /J/ / /7'i/ / % / _ Jo / / / / ./i / / / / /'/ / /� +4' FE it 1=1 C) lli`l)(I ;( 1 [i ..1 L! /�/ / / /// ; /,./ ,/ / / //// / / / / / .`/'//, % //' 7/ , ,i /,�/// /._.. ;/ ////' / / [ / / FEC ads u R 1:1) / / / FEC ELECTRICAL / COMMUNICATION PLAN SCALE: 1 /8" =1'-0" 0 5' 10' 20' 30' li NORTH ELEC / COMMUNICATIONS LEGEND BIS WALL MOUNTED DUPLEX ELECTRICAL OUTLET. B/S WALL MOUNTED DEDICATED 120V 20A DUPLEX ELECTRICAL OUTLET. BIS WALL MOUNTED FOURPLEX ELECTRICAL OUTLET. B/S WALL MOUNTED COMBINATION VOICE/DATA OUTLET BY TENANT. E EXISTING ELEC. / COMMUNICATION NOTES 1. ALL ELECTRICAL OUTLETS TO BE MOUNTED AT 15" A.F.F. (AT BASE OF OUTLET) PER I.B.C. REQUIREMENTS U.N.O. 2. ROUGH IN ALL DATA AND COMMUNICATION LINES - MUD RING WITH PULL STRING, U.N.O. 3. PROVIDE NEW COVER PLATES AND RECEPTACLES AS NEEDED TO MATCH BUILDING STANDARD. 4. MAINTAIN EXISTING ELECTRICAL OUTLETS UNLESS LOCATION CONFLICTS WITH NEW CONSTRUCTION. bI9 REVIEWED FOR CODE COMPLIANCE APPROVED JAN 17 alla City of Tukwila 1NciLD Li.S� RECEIVED CITY OF TUKWILA JAN 03 2018 PERMIT CENTER Nelco Architecture, Inc. a licensed affiliate of Nelson Worldwide, Inc. 1200 Fifth Avenue, Suite 1300 Seattle, WA 98101 Phone: (206) 408-8500 Fax: (206) 223-4990 Consultant: Description: No: By: Date: PERMIT SET NG, EB 11/10/17 FORT DENT III 7100 FORT DENT WAY TUKWILA, WA 98168 Client: KEURIG GREEN MOUNTAIN 7100 FORT DENT WAY, SUITE 160 TUKWILA, WA 98168 Project Title & Address: ELECTRICAL/ COMMUNICATION PLAN Sheet Title: 8459 REGIS ri I I lit' I MA -8 DOUGLAS EVANS r' STAT E OF \ ASI IIN(,1ON Seal: Proj. No: MS.01614.00 Drawn By: NG Project Manager: LD Designer: EB Reviewed By: LD Approved By; LD A-4' ALL DIMENSIONS AND CONDITIONS MUST BE CHECKED AND VERIFIED ON SITE BY THE CONTRACTOR AND SUB -CONTRACTORS PRIOR TO PERFORMING THE WORK. THE PROJECT MANAGER SHALL BE NOTIFIED IN WRITING OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. © NELSON WORLDWIDE, INC. 2017 ALL RIGHTS RESERVED Nelco Architecture, Inc. a licensed affiliate of Nelson Worldwide, Inc. 1200 Fifth Avenue, Suite 1300 Seattle, WA 98101 Phone: (206) 408-8500 Fax: (206) 223-4990 Consultant: Description: No: By: Date: PERMIT SET NG, EB 11/10/17 FORT DENT III 7100 FORT DENT WAY TUKWILA, WA 98168 Client: KEURIG GREEN MOUNTAIN 7100 FORT DENT WAY, SUITE 160 TUKWILA, WA 98168 Project Title & Address: DOOR & FRAME SCHEDULE, ELEVATIONS & DETAILS Sheet, Title: EXISTING STRUCTURE 8459 r MARK DOUGLAS E -- --- sI vil orV\:AsnIN(iTON Seal: Proj. No: MS.01614.00 Drawn By: NG Project Manager: LD Designer: EB Reviewed By: LD Approved By: LD i; BIS P d. -LAM I 25" I COUNTERTOP AND BACKSPLASH DOOR AND FRAME SCHEDULE >----1-- f-- DRAWER ON (, (75) POUND FULL- EXTENSION SLIDE COLUMN DOOR FRAME HARDWARE SIZE PER ELEVATION ROOM NO. WIDTH HT. THICKNESS TYPE MATERIAL FINISH TYPE MATERIAL FINISH TYPE FINISH NOTES Nisi METAL CLIP METAL STUDS STAGGERED @ 8'-0" O.C. FOR ALL UNBRACED STRAIGHT RUNS OF WALL OVER 12'4)". ATTACH \ TO STRUCTURE ABOVE. OPEN WORK AREA 100A 3' - 0" B/S 1 3/4" DR -1 B/S SC B/S FR -1 B/S B/S A B/S r BIS ADA -COMPLIANT OPEN WORK AREA - CLOSET 100B 4' - 0" B/S 1 3/4" DR -3 B/S SC B/S FR -3 B/S B/S B B/S ° MELAMINE INTERIOR °� ° AS SCHEDULED ° CASEWORK HARDWARE, TYP. OFFICE 101 3' - 0" B/S 1 3/4" DR -2 B/S SC B/S FR -1 B/S B/S A B/S OFFICE 102 3' - 0" B/S 1 3/4" DR -2 B/S SC B/S FR -1 B/S B/S A B/S ° (2) CONCEALED HINGES PER DOOR OFFICE 103 3' - 0" B/S 1 3/4" DR -1 B/S SC B/S FR -2 B/S B/S A B/S TYP.- DOOR & FRAME GENERAL NOTES: HARDWARE TYPES: (2) #10 SCREWS w;.:: . __ .;. _, ,_--,-., ® e A *((/4tH� �It t tlititttlt! l' Ch o o ADJUSTABLE SHELF SCHEDULED CEILING TILE & GRID ° ° la r I f B/S P -LAM LOWER CABINETS WITH DRAWER, DOOR, AND ri ADJUSTABLE SHELF A �■ 1. UNDERCUT THE BOTTOMS OF DOORS TO CLEAR THE TOP OF FINISHED SLAB CONDITIONS AND TRIM EACH DOOR TO FIT CONDITION. DOORS SHALL BE ORDERED WITH BOTTOM STILE SIZED TO ACCOMMODATE 2. CONTRACTOR SHALL REVIEW KEYING WITH CLIENT PRIOR TO REPRESENT'S MASTER. 3. AT EXISTING ENTRY DOOR TO BE RETURNED TO BUILDING INVENTORY. FLOOR, BY 1/2" INCH MAXIMUM, U.N.O. VERIFY TYPE A = B/S LATCHSET WHERE RADICAL VARIATIONS IN FLOOR LEVEL EXIST, THESE UNDERCUT CONDITIONS. TYPE B = B/S ADA COMPLIANT HARDWARE FITTING CYLINDERS. KEY CYLINDERS TO BUILDING PATCH/FILL DIVOTS, HOLES, CRACKS, ABBREVIATIONS: V LATERAL BRACING TENANT WALLS (NO CASEWORK) V.I.F. ' - -://,-=---„ r �----, : 'z,r-' y RUBBER BASE 24" / ,� )( MAX8' MAXS' MAX8' MAX8' MA 8' MAX 2' MAX 1 CASEWORK ELEVATION 3/8"=11-0" 2 I BASE CASEWORK SECTION 1 1l2" = 1-0" SCRATCHES, 4. ALL VERIFY 5. PROVIDE OTHER DOES SUCH 6. THE INTERIOR DO DOOR APPROPRIATE 7. THRESHOLDS LEVEL THAN 8. EXIT HARDWARE 9. HINGE IA GOUGES, ETC. PRIOR TO PRIMING/PAINTING/REFINISHING. NEW DOOR HARDWARE TO MATCH BUILDING STANDARD BUILDING•STANDARD WITH BUILDING REPRESENTATIVE. CODE COMPLIANT HARDWARE. ALL HARDWARE TO BE OPERABLE PARTS ON ACCESSIBLE DOORS SHALL HAVE NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING HARDWARE SHALL BE 34" MIN. AND 48" MAX. ABOVE THE MAXIMUM FORCE FOR PUSHING OR PULLING OPEN DOORS HINGED DOOR = 5.0 POUNDS (22.2 N), SLIDING OR NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH IN A CLOSED POSITION. FIRE DOORS SHALL HAVE A MINIMUM ADMINISTRATIVE AUTHORITY. AT DOORWAYS SHALL NOT EXCEED 0.5 INCH (12.7 CHANGES GREATER THAN 0.25 INCH (6.4 MM) AT DOORWAYS ONE UNIT VERTICAL IN TWO UNITS HORIZONTAL (50 -PERCENT DOORS MUST REMAIN UNLOCKED AT ALL TIMES IN SHALL REQUIRE NO SPECIAL KNOWLEDGE OR SIDE OF DOORS TO BE LOCATED 6" FROM ADJACENT DOOR SCHEDULE B/S =BUILDING STANDARD MANUFACTURER, STYLE & FINISH. CONTRACTOR TO SC = SOLID CORE WOOD LEVER -TYPE. HANDLES, PULLS, LATCHES, LOCKS, AND A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND OF THE WRIST TO OPERATE. OPERABLE PARTS OF FLOOR. OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS: FOLDING DOOR = 15.0 POUNDS (67 N). THESE FORCES BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD THE OPENING FORCE ALLOWABLE BY THE MM) IN HEIGHT. RAISED THRESHOLDS AND FLOOR SHALL BE BEVELED WITH A SLOPE NOT GREATER SLOPE). THE DIRECTION OF EGRESS. PASSAGE EXIT ASSISTANCE TO OPEN OR TO ACCESS. WALL U.N.O. LATERAL BRACING NOTES: PER DETAIL ABOVE (TYP.i 1. LATERAL BRACING IS TO BE INSTALLED INTERSECTIONS WITH WALLS AT LEAST 4 FT. (PER TYP. PART. PLAN) 2. TEMPORARY ATTACHMENT OF PARTITION SET THE WALL UNTIL PERMANENT BRACING SCREWS IS UP TO THE DISCRETION OF THE VERIFY. 3. PROVIDE BRACING AT ANY PERMANENTLY ON TENANT PARTITIONS AT 8 FT. O.C. EXCEPT AT LONG. TOP TRACK TO THE GRID IS PERMITTED TO ALIGN AND IS PROVIDED. REMOVAL OF THE TEMPORARY HOLDING SPECIFIC LOCAL BUILDING OFFICIAL. CONTRACTOR TO PARTITION THAT IS NOT ATTACHED TO CEILING GRID. SCALE: NTS 3'-0" 6'-2"MIN. DIM. 3 NOT USED NA 4 1 NOT USED 3I8"=1'-0" 5 1 PARTITION HEAD BRACING DETAIL NTS 4'-0" WIDE INSULATION PARTITION ACOUSTIC BATT CENTERED OVER ABOVE HUNG CEILING. SEISMIC BRACING STEEL 1' 1 f 1' 1' 1' B/S HEIGHT (±7'-8") VERIFY '1 BIS HEIGHT (±7'-8") VERIFY 'I B/S HEIGHT (±7`-8") VERIFY //�//////j GALV. DEEP LEG DEFLECTION TRACK, ANCHOR TO STRUCTURE WITH HILTI X -U j/// //// (OR NX KU UNIVERSAL KNURLED // / SHANK POWDER DRIVEN SEISMIC BRACING 114" NON-COMBUSTABLE WOOD FILLER UNDER MAIN 1N‘ (BEYOND) i� PER 5/A-5. / / / 1/4" NON-COMBUSTABLE WOOD FILLER (BEYOND) PER 5/A-5. UNDER MAIN BLACK TAPE, FASTENER WITH MIN. 1" RUNNERS. < / 118" BLACK FOAM / TAPE, HOLD BACK 1/4"FOLLOW / FROM EDGE OF TRACK / (BOTH SIDES) RUNNERS. ^ \ 1 it • �, - ^ -�-�-� 1/8 FOAM HOLD BACK 1/4"FROM OF TRACK (60TH uH EDGE SIDES) _._ $ EMBEDMENT @ 16 O.C. EXISTING STRUCTURE ABOVE. ( ' MANUFACTURER'S ° INSTRUCTIONS). 1 . CEILING @ + X' -X" A.F.F. =�+► Ak.CEILING @ + X' -X" A.F.F.im_ ALTERNATE FOR WOOD: - It USE (2) #10 SCREWS AT 16" O.C. HOLD GYP. FASTENERS BACK (WHERE INDICATED ON - METAL TRACK WITH (2) (WHERE INDICATED ON METAL TRACK WITH (2) #10 .( _ REFLECTED CEILING PLAN). . CONTINUOUS 'L' METAL #10 SCREWS AT 16" O.C. REVEAL BLACK) REFLECTED CONTINUOUS .1- CEILING PLAN). 'L' METAL 0...-1� SCREWS AT 16"O.C. REVEAL BLACK) OR `� �� ) FRAME TYPE: (FR -1) FRAME TYPE: (FR -2) FRAME TYPE: (FR -3 ) ( ) 2-1/2" FROM EDGE. TRIM WI PAPER WING (BOTH SIDES OF PARTITION) (PAINT OR MATCH EXISTING TRIM WI SIDES OF PAPER WING (BOTH PARTITION) (PAINT MATCH EXISTING CONDITION. 3 0 3=0 ( CEILING @ + X' -X" A.F.F. t , < < < < < < y! ; (-� t ? ? ) ? ? �� _ V (WHERE INDICATED ON I ;; 1 CONDITION. (BOTH SIDES OF PARTITION) 5/8" FIRE RETARDANT (BOTH SIDES OF PARTITION) REFLECTED CEILING PLAN). ( ) ) EQ. EQ. ACOUSTIC BATT INSULATION . 5l8" FIRE RETARDANT TREATED ACOUSTIC BATT INSULATION. r �.. ( j \---- BIS HEIGHT (±7-8") VERIFY % / b \� BIS HEIGHT (±7'-8") VERIFY \ / / / �,/ ' BIS HEIGHT (±7-8") VERIFY \ ` ` / / / / V 1 1 \ 1 , / 11 1 / / / , AGALV. ( ) \ ✓ - TREATED PLYWOOD BLOCKING AT WALL HUNG ITEMS (WHERE APPLICABLE- REFER TO DRAWING PLANS). ALTERNATE FOR BLOCKING: __ •\/' _) PLYWOOD BLOCKING AT WALL HUNG ITEMS (WHERE APPLICABLE - REFER TO DRAWING PLANS). ALTERNATE FOR BLOCKING: ( ) (--) 5/8" FIRE RETARDANT TREATED �/� GALV. STEEL SILL TRACK. ATTACH TO STRUCTURE WITH HILTI X -U (OR XU15) UNIVERSAL KNURLED SHANK POWER DRIVEN FASTENER WITH MIN. 1" 20" WIDE SHEET METAL AT +40"FROM FLOOR TO BOTTOM (IN LIEU OF WOOD BLOCKING)'' 5/8" GWB, TYPE 'X' EACH 20" WIDE SHEET METAL AT +40" ( ) i� C� PLYWOOD BLOCKING AT WALL HUNG ITEMS (WHERE APPLICABLE -REFER TO DRAWING PLANS). ALTERNATE FOR BLOCKING: STEEL SILL TRACK. ) FROM FLOOR TO BOTTOM (IN ATTACH TO STRUCTURE WITH ( LIEU OF WOOD BLOCKING) HILTI X -U (OR XU15) UNIVERSAL ( ( ) KNURLED SHANK POWER DRIVEN ( - �\ '� FASTENER WITH MIN. 1" ) 518" GWB, TYPE 'X' EACH SIDE \ EMBEDMENT @ 16" O.C. (FOLLOW MANUFACTURERS SIDE EMBEDMENT 1M O.C. ( ( GALV. STEEL SILL TRACK. ) . 20" WIDE SHEET METAL AT +40" DOOR TYPE: (DR -1) DOOR TYPE: (DR -2) DOOR TYPE: (DR -3) yrs (FOLLOW MANUFACTURERS ( � ) :, FROM FLOOR TO BOTTOM (IN 3 0 I T` ee 0 ATTACH TO STRUCTURE WITH ( LIEU OF WOOD BLOCKING) INSTRUCTIONS). FLOORING AS SCHEDULED SIDES OF PARTITION) BASE, AS SCHEDULED. / (BOTH SIDES OF PARTITION.) EXISTING STRUCTURE INSTRUCTIONS). �-�) ) . BASE, AS SCHEDULED. (BOTH SIDES OF PARTITION.) HILTI X -U (OR XU15) UNIVERSAL ( ) ) KNURLED SHANK POWER DRIVEN ' ( ) _ FLOORING AS SCHEDULED < ) FASTENER WITH MIN. 1" ( OF EXISTING STRUCTURE ) ; ` 518" GWB, TYPE 'X' EACH SIDE (BOTH (BELOW) (BOTH SIDES PARTITION) EMBEDMENT @ 16 O.C. / _ I � l,ln, I (BELOW) ( ) / / \ t . / BIS HEIGHT (±7'-8") } EE > REVIEVVED FOR Y _ ; CEDE COMPLIANCE APPROVED JAN 2018Inc~ B.¢TDN (FOLLOW MANUFACTURERS INSTRUCTIONS). ( AS SCHEDULED./ -i, , ��� STUD SCHEDULECity ��� ��� STUD J� / SCHEDULE , ' '! / (-� ��j .: BASE, �� (BOTH SIDES OF PARTITION.) FLOORING AS SCHEDULED ( (BOTH SIDES OF PARTITION) ��� EXISTING STRUCTURE (BELOW) / STUD SCHEDULE ry7/ / 1 B RECITE FRAME TYPE: R-1 f DOOR & RE RECITE TYPES RECEIVED CITY OF TUKWILA STUD SCHEDULE: ,� I STUD SCHEDULE: STUD SCHEDULE: 2-112" 3-5/8" 6" NOTES: 1. ALL 2. USE FOR 3. USE = 250S125 27 (22 GA); MAX 10' 0"HIGH,, = 362S125-27 (22 GA); MAX 13'-0" HIGH. = 6005125-27 (22 GA); MAX 17'-6" HIGH. STUDS ARE AT 16" 0.C. SAME GAUGE AS STUDS TRACKS AND CHANNEL. SSMA TECHNICAL GUIDES. j_ ____ ' GALV STEEL STUD, PER STUD SCHEDULE, WITH 5l8" TYPE 'X' GWB EACH SIDE. 2.112" = 250S125 27 (22 GA); MAX 10'-0" HIGH. 3 518" = 362S125 27 (22 GA); MAX MPGALV STEEL STUD, PER STUD SCHEDULE, WITH 518" TYPE'X' 2-1/2" = 250S125-27 (22 GA); MAX 10'-0"HIGH. I% GALV STEEL STUD, PER STUD 13'-0" HIGH. 6" = 600S125-27 (22 GA); MAX 17'-6"HIGH. NOTES: 1. ALL STUDS ARE AT 16" O.C. 2. USE SAME GAUGE AS STUDS FOR TRACKS AND CHANNEL. 3. USE SSMA TECHNICAL GUIDES. GWB EACH SIDE. 3 518 - 362S125 27 22 - ( GA); MAX 13'-0"HIGH. 6" = 6005125-27 (22 GA); MAX"" 17-6"HIGH. NOTES: 1. ALL STUDS ARE AT 16" O.C. 2. USE SAME GAUGE AS STUDS FOR TRACKS AND CHANNEL. 3. USE SSMA TECHNICAL GUIDES. -' SCHEDULE, WITH 5l8" TYPE 'X' GWB EACH SIDE. 1/4" _ " SCALE : -1-0 JAN 03 2018 PERMIT CENTER 6 BIS TENANT SOUND PARTITION 3"=1'-0" 7 B/S TENANT PARTITION 3"=1'-0" 8 BIS CORRIDOR PARTITION 3"=1'-0" * FRAME, DOOR & RELITE SCHEDULE & TYPES• 1/4"=11-o° Nelco Architecture, Inc. a licensed affiliate of Nelson Worldwide, Inc. 1200 Fifth Avenue, Suite 1300 Seattle, WA 98101 Phone: (206) 408-8500 Fax: (206) 223-4990 Consultant: Description: No: By: Date: PERMIT SET NG, EB 11/10/17 FORT DENT III 7100 FORT DENT WAY TUKWILA, WA 98168 Client: KEURIG GREEN MOUNTAIN 7100 FORT DENT WAY, SUITE 160 TUKWILA, WA 98168 Project Title & Address: DOOR & FRAME SCHEDULE, ELEVATIONS & DETAILS Sheet, Title: • 8459 r MARK DOUGLAS E -- --- sI vil orV\:AsnIN(iTON Seal: Proj. No: MS.01614.00 Drawn By: NG Project Manager: LD Designer: EB Reviewed By: LD Approved By: LD A-5 ALL DIMENSIONS AND CONDITIONS MUST BE CHECKED AND VERIFIED ON SITE BY THE CONTRACTOR AND SUB -CONTRACTORS PRIOR TO PERFORMING THE WORK. THE PROJECT MANAGER SHALL BE NOTIFIED IN WRITING OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. © NELSON WORLDWIDE, INC. 2017 ALL RIGHTS RESERVED