Loading...
HomeMy WebLinkAboutPermit D18-0007 - KOTIS DESIGN - DEMISING WALL AND OPENINGKOTIS DESIGN 1165 ANDOVER PARK W EXPIRED 9/05/18 018-0007 Parcel No: Address: c City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 3523049097 1165 ANDOVER PARK W Project Name: KOTIS DESIGN DEVELOPMENT PERMIT Permit Number: D18-0007 Issue Date: 2/13/2018 Permit Expires On: 8/12/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: ICON OWNER POOL 1 WEST LLC 2 N RIVERSIDE STE 2350 , CHICAGO, WA, 60606 DAVID KEHLE 1913 BONAIR DR SW , SEATTLE, WA, 98116 ALEXEEV CONSTRUCTION PO BOX 731152 , PUYALLUP, WA, 98373 ALEXECS934P9 CAL WEST INDUSTRIAL HOLDINGS 631 STRANDER BLVD - SUITE G , TUKWILA, WA, 98188 Phone: (206) 433-8997 Phone: (253) 230-4788 Expiration Date: 10/29/2019 DESCRIPTION OF WORK: CONSTRUCT NEW FULL HEIGHT DEMISING WALL AND CREATE 8 FT X 10 FT OPENING IN EXISTING SHEAR WALL Project Valuation: $16,500.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: Type of Construction: IIIB Electrical Service Provided by: TUKWILA Fees Collected: $760.96 Occupancy per IBC: S-1 Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: r1N Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: k7f2A'h41i tZ1i1/W Date: IP )IS I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does n resume to give - 9.rity to violate or cancel the provisions of any other state or local laws reg a ing co ction or t •erformai ce of work. I am authorized to sign and obtain this development perm' an agre the condi ons attach d to this permit. Signature: Print Name: Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 9: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 10: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 11: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 13: Maintain fire extinguisher coverage throughout. 14: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1010.1.9) 15: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 16: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1010.1.9.1) 17: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1013.1) 18: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1013.6.1) 19: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1018.1) 20: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on-site generator. (IFC 1013.6.3) 21: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1008.3.5) 25: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 23: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 22: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 26: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 27: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 28: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 29: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.11 of the International Building Code. 24: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 30: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 31: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0611 EMERGENCY LIGHTING 1400 FIRE FINAL 0409 FRAMING 0413 WALL SHEATHING/SHEAR 0 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http:;'%vvvvvv. iIaVv'A.i o Building Permit No. b 1.e) - CX l Project No. Date Application Accepted: Date Application Expires: t -9H1 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 1IC.e • t1(01 )41004021Tiat PROPERTY OWNER Name: \ Ibt kel AddressG2o 31`%� OIL. _" �PAM q City:1mpg )410 King Co Assessor's Tax No.14,2-44 71+ Suite Number: E3 Floor: Tenant Name: .6:4114 New Tenant: 0 Yes 'No CONTACT PERSON — person receiving all project communication Company Name:Vjr eu—comenzik.19 iv.l. ��u,� Name:'�j e/ ,.,, ��rf iimitzur Zipu`e$ CONTACT PERSON — person receiving all project communication Company Name:Vjr eu—comenzik.19 iv.l. ��u,� Name:'�j e/ ,.,, ��rf iimitzur Architect Name b Address:'a `� T 'v`',w, 04 Phone •1000 Fac: City:C/L Stater t J Zip`, Zipielk, Phone/ e ,+inn}Faax:: State: Email: AIhehk Q Af ux'Yie,.(0rvl Zip: GENERAL CONTRACTOR INFORMATION Company Name:Vjr eu—comenzik.19 iv.l. Company Name:-{'Qp 11''�✓�✓++'' Architect Name b Address: Phone •1000 Fac: City / State: VA . Zipielk, City: State: Emaigmese a Ak - r1_, coliA Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: H:\Applications\Form-Applications On Line \2011 Applications\Permit Application Revised - 8-9.11.docx Revised: August 2011 bh ARCHITECT OF RECORD Company Name:Vjr eu—comenzik.19 iv.l. Company Nam iotia st1426„ l e vl ""! Architect Name b Address: letj (i 1&714,61,0 Via G>'� Phone •1000 Fac: City / State: VA . Zipielk, Phone:/,4 4,1,61...Fax: Emaigmese a Ak - r1_, coliA ENGINEER OF RECORD Company Name:Vjr eu—comenzik.19 iv.l. Engineer Nam c%e Vittv,t4 Address: .34,0065� . 44,46...15, 44..f, City: ma. State: Loio. Zip:'Iq ci+ Phone •1000 Fac: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) .\ Name J\ Address: City: State: Zip: Page 1 of 4 0 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ ICO.°1112> Existing Building Valuation: $ 1Atitiu404 Describe the scope of work (please provide detailed information): etuvrtAtat Nei Thu ' Elco' VeINvpiNr, tuba, iuc ¢ N x z gfunax( iK VistrtictG¢. Will there be new rack storage? ❑ Yes NteNo If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Flobr area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 04) Compact: Handicap:I CO Will there be a change in use? 0 Yes No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinlders 0 Automatic Fire Alarm 0 None 0 Other (specify) • Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes jt No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Form-Applications On Line\2011 Applications\Permit Application Revised - 8-9-11.docc Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 15r Floor 101$91-1 s ��%(J ft iii -e-4, '1 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Flobr area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 04) Compact: Handicap:I CO Will there be a change in use? 0 Yes No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinlders 0 Automatic Fire Alarm 0 None 0 Other (specify) • Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes jt No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Form-Applications On Line\2011 Applications\Permit Application Revised - 8-9-11.docc Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction —In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 R O 91ORIZED AGENT: Signature: Q. ,meq f� Print Name' 4IY W*%½4,1 Day Telephone:40 433 Date: ottc�l�� Mailing Address: tAite ettua CAL 4 H:\Applications\Forms-Application On Line \2011 Applications\Pemtit Application Revised - 8-9-11.docc Revised: August 2011 bh City State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT 1 QUANTITY ' PAID $471.78 D18-0007 Address: 1165 ANDOVER PARK W Apn: 3523049097 $471.78 Credit Card Fee $13.74 Credit Card Fee R000.369.908.00.00 0.00 $13.74 DEVELOPMENT $436.44 PERMIT FEE R000.322.100.00.00 0.00 $431.94 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $21.60 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R13783 R000.322.900.04.00 0.00 $21.60 $471.78 Date Paid: Tuesday, February 13, 2018 Paid By: ADAM GRANT Pay Method: CREDIT CARD 012330 Printed: Tuesday, February 13, 2018 2:51 PM 1 of 1 CSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS I PermitTRAK ACCOUNT QUANTITY PAID $289.18 D18-0007 Address: 1165 ANDOVER PARK W Apn: 3523049097 $289.18 Credit Card Fee $8.42 Credit Card Fee R000.369.908.00.00 0.00 $8.42 DEVELOPMENT $280.76 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R13241 R000.345.830.00.00 0.00 $280.76 $289.18 Date Paid: Monday, January 08, 2018 Paid By: DAVID KEHLE Pay Method: CREDIT CARD 07202D Printed: Monday, January 08, 2018 2:02 PM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: ,.4 g /0/7 !S DCS (c Type of Inspection: Address: Date Called: Special Instructions: P�''a) I`iCr '3D -- ?/ 5 Date Wanted: 3-9-6 Ca ' J p.m. Requester: Phone No: 2s 3 -?,31-2,2 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 67/01-771/10- 0K-ta&t y-- Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. r Envelope Summary ?015 WSEC Compliance Forms for Com ercial Buildings including R2, R3, & R4 over 3 stories and all R1 ENV -SUM Revised Jun 2016 Project Info P Me: - :.-. -:: _ - - Date ��I OI Compliance forms Applicant Information. Provide contact information for individual who can respond to inquiries about compliance form information provided. For Building Department Use do not require a password to use, Company Name: riotri, cells calculating are calcinstrulating Companyi Andress/(2C -• Witt tg 1IVe '�`"' ''`� write -Protected- ii Applicant Nameatpr3L Cal Applicant Phone' f3 ;, , -4 Applicant Email: Wig Q , atm. tem Project Description ■ New Building ■ Addition 0, Alteration Occupancy Type Selection required to enable forms. • All Commercial 0 Group R - All R1 and R2, R3, R4 over 3 stories 0 Envelope Compliance Path Selection required to enable forms. o prescriptive 0 Component Performance 140111414146 Component Performance Calculation Type O Standard 0 Change of Occupancy/Conditioning 0 Selection required to enable ENV -UA and ENV-SHGC forms. • Additional Efficiency Package Option - C406.8 Enhanced Envelope To comply, demonstrate building thermal envelope performance is 15% lower than the Target UA. Air Barrier Testing • Air barrier testing per Section C402.5.1.2 ■ Air barrier testing not required included in project scope • Additional Efficiency Package Option - C406.9 Reduced Air Infiltration To comply, demonstrate that measured air leakage of building envelope does not exceed 0.25 chnAt2 (air barrier surface area) under test pressure of 0.3 inch w.g. Vertical Fenestration and Skylight Area Calculation Total Vertical Gross Exterior Fenestration Above Grade % Vertical (rough opening) . divided by Wall Area times 100 equals Fenestration Prescriptive Path - Enter values for vertical fenestration, skylights, g walls et. _ X 100 = and roof on this ENV -SUM worksh Component Performance - Enter values in ENV -UA and/or ENV -UA -GROUP -R from Gross Exterior Roof Total Skylight divided by Area times 100 equals % Skylight worksheet. These values auto-fhl ENV -UA and are write -protected on ENV- _ X 100 = Fenestration Area Compliance Vertical Fenestration area REVIEWED FOR CODE COMPLIANCE APPROVED RECEIVED CITY OF TUKWILA JAN 0 � 208 Skylight Area JAN 19 2018 , IPF.RMIT CENTF.{ Vertical Fenestration Alternates 0 High performancefehestrat'� � armor aDr d-vSvH`C per ('t,,402.4.1.3 0 Dedicated outdoor aar prim fiin lC4ti2.4:aq,4 and C4036 Show locations of qualifying daylight --zone areas and ft2 on project plans. For Daylight Zone Area Calculations - a) Sidelight areas include primary+ 0 In buildings a 3 storm; 25%`tit more 6f NET flock -area -is in daylight zones per C402.4.1.1 0 In buildings < 3 stories, 50% or more of CONDITIONED floor area is within daylight zones per C402.4.1.1 Daylight Zone Calculations secondary daylght zone areas. b) include overlapping toplight and Daylight Zone Fenestration Attemate Not Selected. No Calculations Required Sidelight Daylight Toptight Daylight Zone Area Zone Area Percent Daylight Zone Area sidelight daylight zone areas under Toplight c) Refer to Chapter 2 for net floor area . dab Spaces in Single Story Building Requiring Skylights List all enclosed spaces that a 2,500 , ave ceiling fight greater than 15f and are space h required to comply with this provision. Code requires a minimum of 50% of the floor Space Area (ft2) DLZ Area (ft) SRR or Aperature Exception area to be within a skylight daylightzone for enarifin snare times Refer to 0.4024-2 for 4 L. A. u.. J.. b _ - - - ell ...etfal i Lighting Summary 2015 Washington State Energy Code t ompliance Forms for Commensal Buildings including R2, R3, R4 over 3 stories and all RR11 LGT-SUM Revised August 2016 Project Info Compliance forms do not require a password to use. Instructional and calculating cells are write - protected. Project Title: Applicant Information. Provide contact information for individual who can For Building Department Use respond to inquiries about compliance form information provided. Company Name: it Company Address: WA . Nwiti geR.aG[ Applicant NamerAmo % 4jaz'wfi Applicant Phone:/.44/ Applicant Email: %k t Aliehlearckstom 0 New Building 0 Addition IX Alteration 0 Plans Included Include PROJ-SUM form (included in envelope forms workbook) with lighting complliance forms. Interior lighting Exterior lighting Project Description Building Additions Refer to Section C502.2.6 for additional requirements. Compliance Method Lighting systems in addition area comply with all applicable provisions as a stand alone new construction project Lighting systems in addition are combined with existing building lighting systems to demonstrate compliance 0 Addition is combined witir existing: For Interior lighting projects, include new + existing interior lighting fixture wattage in Proposed Lighting Wattage table in LTG -INT -BLD or LTG-iNT-SPACE form. For wattage in Proposed For exterior fighting projects, include new +exing exterior �w wattage Tradable and Proposed Non -Tradable Lighting Wattage Interior and Exterior Lighting Alterations Select all Lighting Power and Lighting Control elements that apply to the scope of the retrofit project. If project includes a combination of spaces where less than 50% of the existing fixtures are replaced in some spaces, and 50% or more of the fixtures are replaced in others, then provide separate lighting power compliance forms for the two retrofit conditions. Spaces undergoing the same type of retrofit may be combined into one lighting power compliance form. Refer to Section C503.6 for additional requirements. All alteration fighting controls shall be commissioned per C408.3. jyr No changes are being made to the interior or exterior lighting systems and existing space uses and configuration are not changed Lighting Power Interior lighting 50% or more of existing are replaced ❑ Less than 50% of existing are replaced Parking garage Exterior lighting Lamp and/or ballast replacement only —40 0 ( 0 existing total wattage not increased 4 power of new + existing -to -remain fixtures shall comply with total 50% or morereplaced0405.4.24- Tandtal lighting..Include+ in fixtures in Proposed LPA per Sections 0405.5.2 new existing-to-rema� Lighting Wattage table in LTG -INT -BLD, LTG -INT -SPACE or LTG -EXT form. Less than 50% replaced - Total fighting power of new + existing -to -remain fixtures shall not exceed the + nn fixtures in the Proposed Lighting total lighting power Prior to alteration. Include new existing -to -remain Wattage table in LTG -INT -BLD, LTG -INT -SPACE or LTG -DCT form. sand total 50% threshold applies to number of luminaires for interior spaces and parking garages, installed wattage for exterior luminaires. Lighting Control Interior lighting Parking garage Exterior lighting New wiring installed to serve added fixtures andlor fixtures relocated to new circuit(s) New or moved lighting panel 0 0 ❑ 0 Interior space is reconfigured - i 0 luminaires unchanged or relocated only New wiring or circuit - For interior lighting, provide required manual controls per 0405.2.3, occupancy sensor controls per 0405.2-1. daylight responsive controls per 0405.24 and application specific lighting controls per 0405.2.5. For exterior lighting, provide required controls per C405.2.7. New or moved panel - Provide all applicable lighting controls as noted for New wring and automatic time switch controls per C405.22 Reconfigured fntedorspace - Provide all required fighting controls that apply rto o a nredew ntecesrior space. Application specific lighting control provisions per 0405.2.5 do not apply Change of Space Use Existing interior lighting systems in areas under -going a change in space use are upgraded to ❑ comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2). Identify intortor spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in LTG -INT -BW or LTG -INT -SPACE foto. IINTpgi DHP-Engineering, P.S. `` Structural Building Design Consultants toi� �nm 32008 32nd Ave S, Suite B, Federal Way, WA 98001 Phone (253) 220-0848 FILO Detail Sketch's & Calculations These calculations and details are for isolated specific detail conditions as listed in this package. The owner wishes to add a wall penetration to the partition wall on Grid 2 as shown in the attached sketch. This wall line is a non -load bearing line as indicated by a major GLB line aligned over the wall. The owner has confirmed that the wall is sheathed with PW and is nailed with 8d at 3" oc (see attached picture from owner page 9). The new opening per detail #2 may be located on grid 2 per detail #1. Project & Location: Kotis Design Wharehouse New Partition Wall (SW) Penetration 1167 Andover Park West Bldg B Tukwila, WA 98188 Client: KOtISDESIGN 1167 Andover Park West Bldg B Tukwila, WA 98188 Structural DHP Engineering, PS Engineering: Structural Building Design Consultants 32008 32nd Ave S, Suite B Federal Way, WA 98001 Project Number: Code: Loads: REVIEWED FOR CODE COMPLIANCE APPROVED JAN 1.92018 BU City of Tukwila 17.079 2015 IBC Lateral Loads: Wind Criteria; NA Seisthic Criteria; see attached calculations September 20, 2017 RECEIVED CITY OF TUKWILA JAN 0 8 2018 PERMIT CENTER D18- 0007 00;; DHP- Engineering, P. S. 1 Alt Structural Building Consultants PROJECT JOB # SHEET Z OF DESIGNED DATE CHECKED DATE 32008 - 32nd Ave. S., Suite B • Federal Way, WA 98001 • Phone (253) 220-0848 • www.dhpengineering.com 'r '-IL - DHP- Engineering, P. S. Structural Building Consultants PROJECT JOB # SHEET /37 OF DESIGNED DATE CHECKED DATE 32008 - 32nd Ave. S., Suite B • Federal Way, WA 98001 • Phone (253) 220-0848 • www.dhpengineering.com !� t DHP Engineering, PS huctn a( iiIdng Corsull s ---- ---Pik 2008 32nd Ave.Soutir, Suite B '.1 Federal Way, WA 98001 ASCE Seismic Base Shear Lic. # : KW -06004293 Shear wall Penetration Check Project Title: Kotis Design New Wall Penetration Protect ID: 17,079 4, PP • New SW Penetration Printed 20 SEP 2017, 12:43PM Fie = L1201711DMJMWA1&LYNX-1.E06 EI +ALC, INC. t983-2017, 8rdd10.t7.8.29, Vot0.17.8.29 Licensee : DHP ENGINEERING Risk Category Calculations per ASCE 7-10 Risk Category of Building or Other Structure : Seismic ImportanoeFaelor Gridded Ss & Sivalues ASCE-7-10 Standard : All Buildings and other structures except those listed as Category 1,111, and IV 1 ASCE 7-10, Page 2, Table 1.5-1 ASCE 7-10, Page 5, Table 1.5-2 ASCE 7-10 11.4.1 Max. Ground Motions, 5% Deriving SS = 1.4419 9, 02 sec response S 1 = 0.5364 9,1.Osec:response Site Class, Site Coeff. and Design Category Site Class abon 'D' : Shear Wave Velocity 600 m t,200 fWsec. Site Coefficients Fa & Fir fusing a ighk>frnesde►Polabon*amiable vats) Maximum Considered Earthquake Acceleration Design Spectral Acceleration Seismic Design Category Resisting System Basic Seismic Force Resisting System .. . Response Modification Coefficient ' R System OverstrengffiFactor • Wo" Deflection Ampifiration Factor ' Cd' Fa Fv 8M8=Fa *Ss . S Mt. = Fv.' S1 Sos S 2f3 S 01-S M1213 latitude = Longitude = t : Seattle, WA 98188 = D 1.00 1.50 • 1.442 • 0.805 • 0.961 • 0.536 D 47.450 deg honer 122.275 deg West ASCE 7-10 Table 20.3-1 ASCE 7-10 Table 11.4-1811.4-2 ASCE 7-10 Eq. 11.4-1 ASCE 7-10 Eq. 11.4-2 ASCE 7-10 Eq. 11.43 ASCE 7-10 Eq. 11.4-4 4SCE 7-10 Table 11.6-18 -2 ASCE 7-10 Table 12.2-1 Bearing Wall Systems Light -framed walls sheathed whvood structural panels rated for shear resistance or steel sheets. • 6.50 Building height Limits : 3.00 4.00 NOTE! See ASCE 7-10 fora applicable footnotes. Category 'A 8 B' Limit No Limit Category "C' Limit No Limit Category "D' Limit Limit = 65 Category•E' :Linmiitit Limit = 65 Crdegoy'P Limit Limit = 65 Lateral Force Procedure Equivalent LateralForm Procedure The 'Equivalent Lateral Force Procedure' is being used accordlnq to the provisions of ASCE 7-1012.8 Determine Building Period Structure Type for Building Period Calculation : Aft Other Structural Systems ' Ct' value 0.020 ' tun' :Heightfromtaselo.hghest leve.= 25.0 it 'x"value = 0.75 Ta' Appmxin>ate fundemental period using Eq. 12.8-7 : 'TL' : Lang period transition periodperASCE 740 Maps 22-12 a 2246 " Cs " Response Coefficient S DS Short Pelted Design Special Response 'R' ::Response Mlodifivatm Facoor = '1' : SesmicImport9nce Factor = Seismic Base Shear ASCE 7-10 Section 12.8.2 Use ASCE 12.8-7 Ta = Ct * (hn A x) = 0.224 sec 8.000 sec Budding Period Ta • Calculated torn Approximate Method selected = 0.224 sec ASCE 7-10 Section 12.8.1.1 0.961 From Eq. 12.8-Z Preliminary Cs 6.50 From Eq. 12.113.812.8.4., QCs need notexceed 1 From Eq. 12.8-5 812.8.6, Cs not be less than Cs Seismic Response Coefficient = Cs = 0.1479 from 12.8.1.1 Fot2 1 b'D —a o►to3S 0.148 0.369 0.042 = 0.1479 ASCE 7-10 Section 12.8.1 W ( see Sum AO below) = Seismic Base Shear V = Cs' W = 0.001 0.00 k - 411101m ! DHP Engineering, PS Structrual Building Consultants ! 320* 32nd Ave South, Suite B Federal Way, WA 98001 ASCE Seismic Base Shear Project Title: Kotis Design New Wail Penetration Engineer Project ID: 17.079 Project Descr: New SW Penetration Vertical Distribution of Seismic Forces k' : hx exponent used on Ta = 100 Tabieofbu fr ..Weights by Floor Levet_ Printed: 20 SEP 2017, 12:43PM Fie=L:1201nux Ao-\1WLYNx-1.Ecs ENERCALC, 19e3-2817, Ba1rk1tt17.8.29, Vecta17.829 ASCE 7-10 Section 12.8.3 Level # Wi : Weight Hi : Height (M Hi9) Cvx Fx-vx • V Sum Stay Shear Sum Story Moment Sum VA= 0.00 k .SumWYI'H1 = 0.00 IA Total Base Shear = 0.00k Base Moment= 0.0k -ft ASCE 7-10 12.10.1.1 Level # Wi Fi Sum Fi Sum Wi Fpx : Calcd Fpx:: Min Fpx : Max Fpx Dsgn. Force Diaphragm Forces : Seismic Design Category "B" to "F" Wpx Weightet levehotcliaptuagm art other structure elements attat laic. 'Fi 'Design'Laterai"Form applied at The Sum Fi San 'Lai. Farce' altaxafeui levelgalus &levels above MIN it'd Forme gLevel 0.20 `S'- ost MAXReq'd Force.Ok,evet •0.40'S •Wpx Fpx: Design ftmeA•Level...., .. ; :"tNpx':SL K:>n) Fi.1Current feYei,n-=:Top Level I,!;I DHP- Engineering, P. S. Structural Building Consultants PROJECT JOB # DESIGNED CHECKED SHEET ' OF DATE DATE 32008 - 32nd Ave. S., Suite B • Federal Way, WA 98001 • Phone (253) 220-0848 • www.dhpengineering.com Table 4.3A Nominal Unit Shear Capacities for Wood -Frame Shear Wa11104,6.7 Wood -based Panels° 1. Nominal unit shear capaci ies shall be adjusted in accordance with 4.3.3 to determine ASD allowable unit shear capacity and LRFD factored unit resistance. For general construction requirements see 4.3.6. For specific requirements, see 4.3.7.1 for wood structural panel shear walls, 4.3.7.2 for particleboard shear walls, and 4.3.7.3 for fiberboard shear walls. See Appendix A for common and box nail dimensions. 2, Shears are permitted to be increased to values shown for 15/32 inch (nominal) sheathing with same nailing provided (a) studs arc spaced a maximum of 16 inches on center, or (b) panels are applied with long. dimension across studs. 3. For species and glades of framing other than Douglas -Fir -Larch or Southern Pine, reduced nominal unit shear capacities shall be determined by multiplying the tabulated nominal unit shear capacity by the Specific Gravity Adjustment Factor = [1-(0.5-01, where G = Specific Gravity of the framing lumber from the NDS (Table 12.3.3A). The Specific Gravity Adjustment Factor shall not be greater than 1. 4. Apparent shear stiffness values G„ are based on nail slip in framing with moisture content less than or equal to 19% at time of fabrication and panel stiffness values for shear walls constructed with either OSB or 3 -ply plywood panels. When 4 -ply or 5 -ply plywood panels or composite panels are used, G. values shall he permitted to be multiplied by 1.2.. 5. Where moisture content of the framing is greater than 19% at time of fabrication, G. values shall be multiplied by 0.5. 6. Where panels are applied on both faces of a shear wall and nail spacing is less than 6" on center on either side, panel joints shall be offset to fall on different framing members. Alternatively, the width of the nailed face of framing members shall be 3" nominal or greater at adjoining panel edges and nails at allipanel edges shall be staggered. 7. Galvanized nails shall be hot -dipped or tumbled. " NtZ Ki.OLeTtoto IIUA R*, 9 E0 , .c13 x YZ = 4-00 ? SVJ3ISAS JNIISIS3a-30S0d 7V21311/1 Fastener Type s Skisr0 A SEISM 13 WIND Sheathing Material Minimum Nominal Panel Thickness (In.) Minimun Fastener Penetration in Framing Member or Blocking ge S In Panel Ed Fastener Spacing (in.) Panel Edge Fastener Spacing (in.) 4 3 2 6 4 3 2 v. (PM G. (klps/ln.) v■ (P N) G. 00811114.) V. ffl (p G. (kips/in. ) v, (Pin G. (kips/in.) Vw (A Vw (A Vw (00 Vw WO(irt.) Wood Structural Panels Stnxturel 146 5/18 1-1/4 Nall (common or galvanized box) 6d 400 088 13 PLY 10 600 OSB 18 PLY 13 780 088 23 PLY 16 1020 088 35 PLY 22 560 840 1090 1430 3/82 7,182 15/32 1-3/8 8d 460 510 560 19 16 14 14 13 11 720 790 860 24 21 18 17 16 14 920 1010 1100 30 27 24 20 19 17 1220 1340 1460 43 40 37 24 24 23 645 715 785 1010 1105 1205 1290 1415 1540 1710 1875 2045 15/32 1-1/2 10d 680 22 16 1020 29 20 1330 36 22 1740 51 28 950 1430 1880 2435 Wood Sural Sheathing4,6 5/16 3/8 1-1/4 360 400 13 11 9.5 8.5 540 600 18' 15 12 11 700 780 24 20 14 13 900 1020 37 32 18 17 505 560 755 840 980 1090 1260 1430 3/82 7/162 15/32 1-3/8CP 440 17 15 13 12 11 10 640 70422 CW 25 19 15 14 13 .820 •ii Cib 31 28 25 17 17 15 1060 1170 1280 45 42 39 20 21 20 615 670 730 895 980 1065 1150 1260 1370 1485 1640 1790 15/32 19/32 1-1/2 10d • 0 22. 19 14 13 920 1020 30 26 17 16 1'I 1330 37 33 19 18 1540 1740 52 48 23 22 870 950 1290 1430 1680 1860 2155 2435 Plywood Siding 5/16 3/8 1-1/4 1-3/8 Nall (galvanized casing) fid 8d 280 320 13 16 420 480 16 18 550 620 17 20 720 820 21 22 390 450 590 670 770 870 1010 1150 Particeboard Sheathing Sheathing - S (MGlue" and M-2 "Exterior Glue") 3/8 Nail (common or galvanized box) 6d 240 15 360 17 460 19 600 22 335 505 645 840 3/8 1/2 8d 260 280 18 18 380 420 20 20 480 540 21 22 630 700 23 24 365 390 530 590 670 755 880 980 1/2 5/8 10d 370 400 21 21 550 810 23 23 720 790 24 24 920 1040 25 28 520 560 770 855 1010 1105 1290 r 1455 Structural Fiberboard Sheathing 1/2 Nail (galvanized roofing) 11 ga. galv. rooting nail (0.120" x 1-1/2" long x 7/16" head) 340 4.0 460 5.0 520 5.5 475 645 730 25/32 11 ga. gab/. roofing nail (0.120* x 1-314" long x 318" head) 340 40 460 5.0 520 5.5 475 645 730 1. Nominal unit shear capaci ies shall be adjusted in accordance with 4.3.3 to determine ASD allowable unit shear capacity and LRFD factored unit resistance. For general construction requirements see 4.3.6. For specific requirements, see 4.3.7.1 for wood structural panel shear walls, 4.3.7.2 for particleboard shear walls, and 4.3.7.3 for fiberboard shear walls. See Appendix A for common and box nail dimensions. 2, Shears are permitted to be increased to values shown for 15/32 inch (nominal) sheathing with same nailing provided (a) studs arc spaced a maximum of 16 inches on center, or (b) panels are applied with long. dimension across studs. 3. For species and glades of framing other than Douglas -Fir -Larch or Southern Pine, reduced nominal unit shear capacities shall be determined by multiplying the tabulated nominal unit shear capacity by the Specific Gravity Adjustment Factor = [1-(0.5-01, where G = Specific Gravity of the framing lumber from the NDS (Table 12.3.3A). The Specific Gravity Adjustment Factor shall not be greater than 1. 4. Apparent shear stiffness values G„ are based on nail slip in framing with moisture content less than or equal to 19% at time of fabrication and panel stiffness values for shear walls constructed with either OSB or 3 -ply plywood panels. When 4 -ply or 5 -ply plywood panels or composite panels are used, G. values shall he permitted to be multiplied by 1.2.. 5. Where moisture content of the framing is greater than 19% at time of fabrication, G. values shall be multiplied by 0.5. 6. Where panels are applied on both faces of a shear wall and nail spacing is less than 6" on center on either side, panel joints shall be offset to fall on different framing members. Alternatively, the width of the nailed face of framing members shall be 3" nominal or greater at adjoining panel edges and nails at allipanel edges shall be staggered. 7. Galvanized nails shall be hot -dipped or tumbled. " NtZ Ki.OLeTtoto IIUA R*, 9 E0 , .c13 x YZ = 4-00 ? SVJ3ISAS JNIISIS3a-30S0d 7V21311/1 aw iPL1i'! �;8i DHP-Engineering, P.S. C. Structural Building Design Consultants gli Argy 32008 32'd Ave S, Suite B, Federal Way, WA 98001 Phone (253) 220-0848 Calculations The owner provided a removal and confirmation of the wall on Grid 2 as having plywood with panel edge nailing of 3" oc and 12" in the field 0City of Tukwila Department of Community Development 8/1/2018 DAVID KEHLE 1913 BONAIR DR SW SEATTLE, WA 98116 RE: Permit No. D18-0007 KOTIS DESIGN 1165 ANDOVER PARK W Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 9/5/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 9/5/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, 'M achelle'Ripley Permit Technician File No: D18-0007 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 QERMIT COORD COPY c PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0007 PROJECT NAME: KOTIS DESIGN SITE ADDRESS: 1165 ANDOVER PARK W X Original Plan Submittal Response to Correction Letter # DATE: 01/08/18 Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: As L' Building Division Otr6 Public Works A Atuc 14-49 Fire Prevention Structural LA1 /VA- H (-r8 Planning Division n Permit Coordinator se PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 01/09/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 02/06/18 Approved Corrections Required ❑ Approved with Conditions ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: - REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 ALEXEEV CONSTRUCTION SVLLC Home Espafiol Contact Safety & Health Claims & Insurance Washington State Department of Labor & Industries Search L&I A -Z Index help Page 1 of 2 SEA My My Workplace Rights Trades & Licensing ALEXEEV CONSTRUCTION SVCS LLC Owner or tradesperson Principals ALEXEEV, ALEXANDR A, MANAGER ALYEKSYEYEV, OLEKSANDR, PARTNER/MEMBER (End: 10/14/2013) Doing business as ALEXEEV CONSTRUCTION SVCS LLC WA UBI No. 602 767 386 PO BOX 731152 PUYALLUP, WA 98373 253-230-4788 PIERCE County Business type Limited Liability Company License Verify the contractors active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. ALEXECS934P9 Effective — expiration 10/29/2007-10/29/2019 Bond ............._ CBIC Bond account no. SF2145 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 10/29/2007 10/22/2007 Expiration date Until Canceled Insurance Ohio Security Ins Co $1,000,000.00 Policy no. BKW53456758 Received by L&I Effective date 10/12/2017 11/16/2016 Expiration date 11/16/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602767386&LIC=ALEXECS934P9&SAW= 2/13/2018 ALEXEEV CONSTRUCTION SVCS LLC rTh No L&I tax debts are recorded for this contrace,License during the previous 6 year period, but some d may be recorded by other agencies. L&I Tax debts License Violations ........................................... No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 157,199-00 • ........................ _...... Doing business as ALEXEEV CONSTRUCTION SERVICIES Estimated workers reported Quarter 4 of Year 2017 "4 to 6 Workers" L&I account contact T1 / DESTINY ADAMS (360)902-4873 - Email: ADAF235@Ini.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes ....................................................... No strikes have been issued against this contractor. Contractors not allowed to bid .........._................................_...._............................._ No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 5 Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602767386&LIC=ALEXECS934P9&SAW= 2/13/2018 MIXED-USE, NON -SEPARATED U5E5 (SECTION 501): TYPE OF CONSTRUCTION: 111-5 GULLY SPRINKLED) 5013 TWO STORY, BUILDING 15 SURROUNDED 8Y 60' OPEN SPACE ALL SIDES. (8,)1 USES) ASSESSOR PARCEL NUME3ER 543255114 LEGAL DESCRIPTION PARCEL B: 352304 91 POR OF SW 1/4 OF SE 1/4 OF SEC 26-23-4 4 POR NUJ 1/4 OF NE 1/4 C1 SEC 35-23-4 BEG AT NE COR OF NW 1/4 OF NE 1/4 SEC 35 TH N 81-44-08 W 30 FT TH N 1-41-29 E ALG W LN OF ANDOVER PARK W 115.66 FT TN N 81-55-024 1101 FT TO TPOB TH 5 81-55-02 E 440.1 FT N 5 1-41-29 W 114.81 FT TO AN ANGLE PT THEREIN TH 51-5I-39 W 682.19 FT TN N 81-55-02 W 440.1 FT TH NLY IN A STRAIGHT LN 191 FT TO TPOB LESS WLY 216.6 FT Q 0/ BUILDING AND SITE BUILDING CODE: ZONING: SITE AREA: APPROX. EXISTING BLDG. (OFFICE 10,618, IUHSE 85,232) TENANT SPACE: OFFICE: AREA OF WORK: STATISTICS: IBC 2015 W/ WA STATE AMENDMENTS TUC (TUKWILA URBAN CENTER) 215,015 SF. (4.94 AC) 95,850 SF. 15,611 SF. 1,140 SF. 3,300 SF. OCCUPANCY GROUPS AND LOADS: 8 (OFFICE) 1)40 SF / 00 ■ 1100CUPANTB S-1(WAREHOUSE) 14,671 SF / 500 ■ 29 OCCUPANTS TOTAL OCCUPANTS a 40 OCCUPANTS TYPE OF CONSTRUCTION: III -5 (FULLY SPRINKLED) PARKING REQUIRED PARKING :OVERALL BUILDING OFFICE: 8,318.4 SF. 9 3.0/1000: 25.0 SPACES RETAIL: 14,641.0 S.F. 6 2.5/1000: 366 SPACES WHSE. 83,5556 SF. ® 1.0/2000: 41.8 SPACES 103 SPACES PARKING SPACES PROVIDED 125 EXISTING PARKING SPACES (NO CHANGE) SCOPE OF WORK: CCNIMUCT NEW RLL HEAT NON-BEAIIs PEMISItM WALL, CUT IN NEUJ 8'X102' OPENING R4 S1EAR WALL, AND OCarr FOR KOTIS. . SEPERATE PERMITS PLUMBING, ELECTRICAL, HVAC, AND SPRINKLER ARE UNDER SEPER4TE PERMITS. OUINER CALWAEST INDUSTRIAL HOLDINGS LLC C/O KIDDER MATHEWS 631 STRANDER BLVD., SUITE G TUKWILA, WA 98188 P14: 253-893-1156 FX: 206-515-0121 FEL COPY P malt oe Plan review approval is subject to errors and omissions. App . , : of construction documents does not authorize the violation of any ado }t j' code o soca. Receipt of approved Field ..y d coy diti < k. , owledged• BY: IM//' - .r AU 80t5i031w 797.00' City of Tukwila BUILDING DIVISION ENERGY CODE NO CHANGES TO BUILDING ENVELOPE NO CHANGES TO EXIST%JG LIGHTING: t - VICINITY MAP SCALE: N.T.3. 6) KEY SITE PLAN SCALE: N.T.S. ilS>i`,'°�! T PE -yMIT EiQUIRED FOR: t�Mechanicat lectrtcal ihr Plumbing as Plpirig ity of Tukwila DING DIVISION e flTJSION-----. chanties hall b mm a e to the scope 1 of work without prior approvalof Tthl�', Bila BuildingDivision.of IVOTa ►Rei :stens will require new plan submittal and may include additional plan review fees. AREAS OF WORK EX. DEMISING WALL iThk --t EXISTING TENANT SPACE NO WORK EXISTING TENANT SPACE NO WORK EXISTING TENANT SPACE NO WORK EXISTING TENANT SPACE NO WORK 1169 KOTIS f+----Fl---F1---A---fl---1}--R---If--11---4--Il--v 41---11---f1- H----8--- —--f}-----U---I:F--U---11---U---U---U---}} --f1--41---f1---1i---II--{f---fl--fl-- - —{1— — -U- — —11— — — —U— — -f}-- — —U— — {}- — 0 SITE PLAN SCALE: 1" = 30' _#=====f1= TENANT 4E4 —�— EXISTING KOT!5 0 C:`Documents and Saftinna%Ail .ft,.,.......____ REVIEWED FOR CODE COMPLIANCE APPROVED JAN 192018 t:'ity of Tukwil BUILD I:;.,l1V1: K N co ▪ m Liz g RECEIVED C TY OF TUKWILA JAN 08 2018 ERMIT CENTER -L. 022b GV,4 w co 0 0 DESCRIPTION 9 w } 0 Y CO to 0 w N 0 0 aS 0 N• O rn� 00 CO� u tO N cD (0 NN w oQ LLOCO n1- (:)_' th Z cC_1 X00 (0 rnO)0 C>� o z c'T:s1 w U) E," 1arn W H o WZEI CLIr o H WQ z W Wi co-et4 O7:11-1 CD SD 1 � n la 61 BLDG E BLDG p BLDG C (BLDG 5 / / 4 BUILDING A 6) KEY SITE PLAN SCALE: N.T.S. ilS>i`,'°�! T PE -yMIT EiQUIRED FOR: t�Mechanicat lectrtcal ihr Plumbing as Plpirig ity of Tukwila DING DIVISION e flTJSION-----. chanties hall b mm a e to the scope 1 of work without prior approvalof Tthl�', Bila BuildingDivision.of IVOTa ►Rei :stens will require new plan submittal and may include additional plan review fees. AREAS OF WORK EX. DEMISING WALL iThk --t EXISTING TENANT SPACE NO WORK EXISTING TENANT SPACE NO WORK EXISTING TENANT SPACE NO WORK EXISTING TENANT SPACE NO WORK 1169 KOTIS f+----Fl---F1---A---fl---1}--R---If--11---4--Il--v 41---11---f1- H----8--- —--f}-----U---I:F--U---11---U---U---U---}} --f1--41---f1---1i---II--{f---fl--fl-- - —{1— — -U- — —11— — — —U— — -f}-- — —U— — {}- — 0 SITE PLAN SCALE: 1" = 30' _#=====f1= TENANT 4E4 —�— EXISTING KOT!5 0 C:`Documents and Saftinna%Ail .ft,.,.......____ REVIEWED FOR CODE COMPLIANCE APPROVED JAN 192018 t:'ity of Tukwil BUILD I:;.,l1V1: K N co ▪ m Liz g RECEIVED C TY OF TUKWILA JAN 08 2018 ERMIT CENTER -L. 022b GV,4 w co 0 0 DESCRIPTION 9 w } 0 Y CO to 0 w N 0 0 aS 0 N• O rn� 00 CO� u tO N cD (0 NN w oQ LLOCO n1- (:)_' th Z cC_1 X00 (0 rnO)0 C>� o z c'T:s1 w U) E," 1arn W H o WZEI CLIr o H WQ z W Wi co-et4 O7:11-1 CD SD 1 TYPICAL WALL FRAMING ATTACH BOTTOM TRACK TO CONC. FLOOR W/ POWDER DRIVEN ANCHORS, HILTI OR APPROVED 1" EMBEDMENT AT 14" O.C. 5/8" GYP. BD. CONC. SLAB ON GRADE UJ,4LL TO SLAB SCALE: 1-1/2" • 1'-0" ROOF STRUCTURE GYP. BD. EA SIDE +1 1/2" SPACE GYPBD. TO STRUCTURE HEAD DETAIL I,EFLECTION 6" DEEP LEG TRACK ATTACH TO G.L.B. W/3 - 15/8" SCREWS m 2'-0" O.C. (DEEP LEG 15 3") STUDS PER SCHEDULE. e 2'-0" O.C. NOT ATTACHED TO TRACK BUT LAPPED UP INSIDE 1". GYPBD. ATTACHED TO STUD -NOT TO STRUCTURE OR TRACK SECTION CWP. t31) JAMB DETAIL SEE STRUCTURAL FOR D81. 2X6 PF 9 EACH SIDE OF OF'ENNG 5/8" GYP BD. WRAP W/ MTL CORNERS 5/8" GYP BD. EACH SIDE SCALE: I-1/2" = I'-0" SECTION • • N.7 IXI • fEXISTING FULL HEIGHT NON BEARING DEMISING WALL (WALL TYPE A) • N-7 1X1 V..N 24'-4" EXISTING SMOKE VENTS IN EXISTING ROOF TYP. • EX. RAMP E4 EXIT • O EX. OFFICES NO CHANGES 1,140 SF E21 v IXI V.A CONSTRUCT NEW FULL I-EI6141 NON BEARM DEMI8ft' A14LL (11 A . TYPE Aid—\ IXI V. • EXISTING WAREHOUSE AND MANUFACTURING 11,2918Ff1/500: 23 OCC. TWO EXIT DUE TO TRAVEL DISTANCES N. 7 ILA u WAREHOUSE 3,380 8F NOT HIGH PILED 1000PANTB STORAGE T-1 123'-6" a v N.7 IXI CUT IN NEW S'XI0 OPENING N AN EXISTING SHEAR WALL, SEE ELEVATION OF DOOR OPENING T-2 N.7 IXI ■ EXISTING 12'X12' OPENING F VA v' €D1 • EXISTING WAREHOUSE AND MANUFACTURING 14,938 5F6I/500: 30 OCC. TWO EXIT DUE TO RACKS NO WORK IN WAREHOUSE • f EX. DRAFT CURTAIN TO REMAIN • EXISTING SMOKE VENTS IN EXISTING ROOF TY N-7 IXI V. IXI 122' 25'-10 9/16' 124' — -Q ___ _ . _ _ 11_ I I ___ I I _ I I = _jj 11T 11 1-11- 1 111 �-11111111_ ---- — —— —t1---- — — —t' — — — — — — =_____==___===r===__�_=6,321 SF141Q1.4PILED STOR 8,350 SF HIGH PILED STOR 4100 • 63 SF l F VENT, 3 AT 8100 • 84 8F OF VENT, 3 AT 32 SF■96SF 32 SF=96SF NORTH OVERALL FLOOR PLAN: KOTIS EXPANSION scams: inb".v.m. WALL SC1—EULE: A NEW b"XIS GQ. STEEL STUD AT 24" O.G. TO ROOF STRUCTURE ABOVE, WITH 5/8" GYP BD EACH SIDE, AND HEAD DEFLECTION TRACK DOOR SC-4WULE: E1,2,3 EX. 3'X1' STOREFRONT ENTRY DOOR, PADDLE EXIT E2,5,6,1 EX. 3'X1' H. MTL DOOR AND JAMB, LOCKSET (INSIDE HANDLE TURNS FREELY TO EXIT) E8,9,11, EX. 81X10' DOCK HIGH DOORS 13-16 E10,I2 EX. 10'X12' DRIVE IN DOORS E11-21 EX. 3'X1' SC WOOD DOOR AND WOOD JAMB, LOCKSET OR LATCHSET 24-21 22,23 EX. 3'X1' 8C WOOD DOOR AND WOOD JAMB, PRIVACY LOCK 26,28 E29 EX. 12'X'I2' OPENING REVIEWED FOR CODE COMPLIANCE APPROVED 'JAN. 1.9 2018 City of Tukwila RECEIVED CITY OF TUKWILA JAN 08 2018 PERMIT CENTER C:1Documents and Settings\AII Users\Documents\CAD\200210225 GVA-KM1Southcentar Wact Ritainaco D,rl ttriTIC nco n_si -. 0225 GVA U 0 a w J H DESCRIPTION a 9 rn cz 0000 CO 1 1 N (0(0 00 N W O¢ LL Li z(1). st_2, tyv, � Z °Lir Hoo m J LeJ ico 4t4 'V^1 V1 z rA E-1 U) E-1 z 0 E—+ O U. r:4 <4a c:4 0 Q <4z 7-1 a Lc � N 1 AREA OF EXPANSION FOKOTIS S O151'03" W 797.00' 122'-3" DRIVE IN DOCK HIGH DOCK HIGH DOCK HIGH DOCK HIGH DOCK HIGH DOCK HIGH DRIVE IN v gum■ DOCK HIGH XISTfNG LECTRICAL EX. OFFICES NO CHANGE EX. OFFICE NO CNANG • • • 1171 INTERL.INE NO CHANGES • ■ • • • • EX EXIT PATHWAY WITH EMERGENCY LIGHTING EXISTING SHEAR WALL TO REMAIN EX. WAREHOUSE EXISTING NON BEARING DEMISING WALL NEW NON WARNS DEMISING WAU. I:UI.L I4EIGHT EX. WAREHOUSE EX. WAREHOUSE EX. EXIT PATHWAY WITH EMERGENCY LIGHTING EX. WAREHOUSE • 1111 C1 -1,411P4 NO C1-IANGES 1169 EX KOTIS NO CI-1ANGE5 1161 EX KOTIS 1105 EXISTING KOTIS NO Cl-14NGES EX. 12'X12 OPENING' • N • p.------ ---- -----p----- — ___—A---- — -----A---- -�- II 11 II ___ II ___ II IIII II II 11 11 11 11 EX. BEAM EX. STUD UALL, TRIM AS NEEDED EX. WALL 6X8 DWI 8'X10' OPENING 2X6 STUD TO 6X6 -� 112' DIA X6' 'WNW) Q F Ex SLAB • ELEVATION OF NEW OPENING FULL HEIGHT STUD WALL (PLYWOOD ES) ADD RILL HEIGHT STUDS AT JAMB (MIN 2 REQUIRED), STUDS N Dr SCALE: 1/4" = i'-0" NAIL EXISTING PLYWOOD TO NEW STUDS AND 6X8 HEADER WITH Sd COMMON AT 3" O.C. 1/2' DIA X 6' 8IMP80N TITAN HD EXISTING SILL PLATE TRI AS REQUIRED II 11 11 II II „ 1169 II II II II II - d-----t-----t----d-----u-- LF CatION PATH of TRAVEL TO EXIT PATRON( 1161 NORTH --4=== 1====1===41====f=== 1====a==_ _== iii=== =- 1.I 11 11 11 11 11 11 11 11 11 --12 === ====C === 1====t- === 1====tp=== ___tp___ =_: 16 1165 21 FLOOR PLAN: KOTIS EXPANSION SCALE: 1/16°=1'-0" REV 01-05-18 NOTE: EMERGENCY LIGHTING FACILITIES SHALL 13E ARAINGED TO PROVIDE INITIAL. ILLUMINATION THAT 16 AT LEAST AN AVERAGE OF 1 FOOT-CANDLE AND A MINIMUM AT ANY POINT OF 0.1 FOOT-CANDLE MEASURED ALONG THE PATH OF EGRESS AT FLOOR LEVEL. ILLUMINATION LEVELS SHALL BE PERMITED TO DECLINE TO 0. FOOT-CANDLE AVERAGE AND A MINIMUM AT ANY POINT OF 0.06 FOOT-CANDLE AT THE END OF THE EMERGANCY LIGHTING TIME DURATION. A MAXIMUM -TO -MINIMUM ILLUMINATION UNIFORMITY RATIO OF 40 TO 1 61-1ALL NOT 13E EXCEEDED. 6 REVIEWED FOR CODE COMPLIANCE APPROVED JAN 19 2019 City of Tukwila DIVIS11" RECEIVED CITY OF TUKWILA JAN 0 8 2018 PERMIT CENTER C:\Documents and Settinna1AIl UcRrc\nnc„mAnta\r .An\�nnwosn mi,_fRe%e..,.4.4•,....,4.,- In, ._. e.._:____ f,__I_...01.1rI 1 __ . _ 0225 GVA w 0 a m 0 W J a >- 17 0 w 0 w x H DESCRIPTION 0 co 0 >- 0 0 N N A PROPOSED TENANT IMPROVEMENT FOR: KOTIS DESIGN EXPANSION ti (f)Oco 1— IJ 1CC — Q Q Z O mJ coQ O) w rI— v)rn z z QO r:4 H c)z. Cn E—+ BUSINESS SOUTHCENTER CD ao 0 =2