Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D18-0012 - A WIRELESS - TENANT IMPROVEMENT
A WIRELESS 1240 SOUTHCENTER MALL D18-0012 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 9202470010 1240 SOUTHCENTER MALL Project Name: A WIRELESS Permit Number: D18-0012 Issue Date: 2/7/2018 Permit Expires On: 8/6/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD, WA, 92013 APRIL HOUSE 3617 SW CHARLESTON ST , SEATTLE, WA, 98126 M P I AMERICA LLC 1836 SE TENINO ST, PORTLAND, OR, 97202 MPIAMP1952L8 A WIRELESS 1240 SOUTHCENTER MALL , TUKWILA, WA, 98188 Phone: (206) 478-0844 Phone: (360) 693-5735 Expiration Date: 8/14/2019 DESCRIPTION OF WORK: TENANT IMPROVEMENT: DEMO AND INSTALLATION OF NON STRUCTURAL PARTITIONS, FINISHES AND FIXTURES Project Valuation: $80,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: Type of Construction: 11B Electrical Service Provided by: TUKWILA Fees Collected: $2,260.77 Occupancy per IBC: M Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: )74u1jVJI 1Date: fll) ) I 1 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws re: la��g construction or the performance of work. I am authorized to sign and obtain this development per it an agree to the conditions attached to this permit. Signature: Print Name: ff-freo---- Date: -7-yr This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 3: Insulating materials, where exposed as installed in buildings of any type of construction, shall have a flame spread index of not more than 25 and a smoke development index of not more than 450. Where facings are installed in concealed spaces in buildings of Type III, IV, or V construction, the flame spread and smoke - developed limitations do not apply to facings, that are installed behind and in substantial contact with the unexposed surface of the ceiling, wall or floor finish. 4: Fire retardant treated wood shall have a flame spread of not greater than 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 5: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one-third and lower one-third of the water heater's vertical dimension. A minimum distance of 4 -inches shall be maintained above the controls with the strapping. 9: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 6: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 7: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 8: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 10: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1010.1.9) 11: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 12: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 13: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1010.1.9.1) 14: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1018.1) 18: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 16: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 15: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 19: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2437. 21: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 20: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 22: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 23: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.11 of the International Building Code. 24: Post address on storefront per approved Westfield standards. l 17: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 25: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 26: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0606 GLAZING 0502 LATH/GYPSUM BOARD 0406 SUSPENDED CEILING CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. D\'tJ)V1 Project No. Date Application Accepted: n 1 1 Date Application Expires: 1111 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 920247-0010 Site Address: 1240 Southcenter Mall -Tukwila WA 98188 Tenant Name: A Wireless Suite Number: 354 Floor: 3 PROPERTY OWNER Name: April House - Paroline & Associates Name: Westfield Southcenter Mall City: Seattle State: WA Zip: 98126 Address: 2800 Southcenter Mall Email: april@parolineassociates.com City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: April House - Paroline & Associates Address: 3617 SW Charlestown St City: Seattle State: WA Zip: 98126 Phone: (206) 478-0844 Fax: Email: april@parolineassociates.com GENERAL CONTRACTOR INFORMATION Company Name: TBD Address: Address: 7402 East Broad St. Architect Name: David Adkow Phone: (614) 322-7050 Fax: City: State: City: Scottsdale State: AZ Zip: Phone: Fax: Email: Davidadkow@cox.net Contr Reg No.: Exp Date: Tukwila Business License No.: H:\ Applications\ Forms -Applications On Line\2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh New Tenant: m Yes D ..No ARCHITECT OF RECORD Company Name: Applied Engineering Group LTD Company Name: Address: 7402 East Broad St. Architect Name: David Adkow Phone: (614) 322-7050 Fax: Address: 11881 North 113th Way City: Scottsdale State: AZ Zip: 85259 Phone: (480) 614-3385 Fax: Email: Davidadkow@cox.net ENGINEER OF RECORD Company Name: Applied Engineering Group LTD Engineer Name: Dan Rhodes Address: 7402 East Broad St. City: Blacklick State: OH Zip: 43004 Phone: (614) 322-7050 Fax: Email: chris@aegltd.com LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: ,A- Wiee_IeSS Address: e✓ 4 v r 1411 3011 12yn ve City: .-�-��ul' 1 a State: W A Zip: 610 Sci Page 1 of 4 BUILDING PERMIT INFORMATIO Vim— 206-431-3670 '.1•• Valuation of Project (contractor's bid price): $ 80,000 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): Tenant Improvement: Demo and installation of non stuctural partitions, finishes and fixtures. Will there be new rack storage? ❑ Yes EZ1.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ® Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes 0 No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Applications\Forms-Applications On Line \2011 Applications\Pemtit Application Revised - 8-9-11.docx Revised: August 2011 am Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1st Floor 940 940 940 2-B Mercantile Tui Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ® Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes 0 No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Applications\Forms-Applications On Line \2011 Applications\Pemtit Application Revised - 8-9-11.docx Revised: August 2011 am Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN OR AUTnHORi1Z D AGENT: Signature: .. /� J 4 Li' Date: 01/11/2018 Print Name: April House - Paroline & Associates Day Telephone: a©� L% O$ U Mailing Address: 3617 SW Charlestown St Seattle WA 98126 H1ApplicationsWorms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-11 .docx Revised: August 2011 bh City State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT 1 QUANTITY I PAID $2,646.61 D18-0012 Address: 1240 SOUTHCENTER MALL Apn: 9202470010 $2,260.77 DEVELOPMENT $2,194.41 PERMIT FEE R000.322.100.00.00 0.00 $1,327.22 PLAN CHECK FEE R000.345.830.00.00 0.00 $862.69 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $66.36 TECHNOLOGY FEE R000.322.900.04.00 I 0.00 $66.36 EL18-0043 Address: 1240 SOUTHCENTER MALL Apn: 9202470010 $385.84 ELECTRICAL $367.47 PERMIT FEE MULTI-FAM/COMM 1 R000.322.101.00.00 I 0.00 $367.47 TECHNOLOGY FEE $18.37 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R13348 R000.322.900.04.00 0.00 $18.37 $2,646.61 Date Paid: Thursday, January 11, 2018 Paid By: PRECISION PERMIT SERVICES Pay Method: CHECK 15680 Printed: Thursday, January 11, 2018 2:30 PM 1 of 1 CRWSYSTEMS b 18'-4-cz. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431-3670 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 Project: 4 wii2ae- ss Type of Inspection: ZuIL D1 iG iiii-C— Address: Date Called: Special Instructions: g1Z`JV6- evILPfrl.6- fi -L, Date Wanted: �2 Fa48 a p.m.' Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: V_O LA 7 /4-pplAte i�Id. 1_1— Inspector c 1� Date: 3-2fir-Zane REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INS!' ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: A- te/mx1-(ss V'-" Type of Inspection: , 6ILQilia- fiiW- Address: /2 9EP a'ovriieW737? R1.t- Date Called: Special Instructions: /f "viLD/ Pi�a` �*�, Date Wanted: a.m i�3 /e3 p.m. Requester: Phone No: Approved per applicable codes. � Corrections required prior to approval. COMMENTS: /,?CD /1)e -J /11(CLS,c4.4 <14 Dr -f Croce- rrZ. s ,4- ,, /ed -rd. Z� XniSLl f e,C' c/ipet n F sf uye F0.11 - Inspector: give GAL Date:s/z3/zoitc REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project:,QJ A t� LeSC Type of Inspecti .n: 6cl s td. Ca; I IrL Address:/44k /240 �o,,,-�$.O Call d: ki Special Instructions: SoLki,1l 4_,,r M"`L'� Date Wanted: 3- r /r p.m. Requester: i ell Phone No: '771-501.0- 8132 r Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: �S K - 5i)si' -o (-IX/O'YG Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: 041 Of Date: g2 21/ S' Type of Inspection:v 1�- 6 Address: Suite #: 12-4'0 S ‘-- �' Contact Person: TO Special Instructions: 4---p 11-4\/t9 r- P12-t)v 1 6 6-A. Phone No.: 1(E -"SDS 7f Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Date: g2 21/ S' Fire Alarm: Hood & Duct: Monitor: 67 (, 0/ Pre -Fire: j/ 7 --/E, �'�U 4---p 11-4\/t9 r- P12-t)v 1 6 6-A. KEE- Csc t fJ 1(E -"SDS 7f ,' i2 -E- ,el N ft t/2 -6Y L .---13 .g; 2_3//g, z E 9k .4-2,0 Cd o ? 4-1 Needs Shift Inspection: Sprinklers: Date: g2 21/ S' Fire Alarm: Hood & Duct: Monitor: 67 (, 0/ Pre -Fire: Permits: Occupancy Type: AA Inspector: F-70 S-21-- Date: g2 21/ S' Hrs.: if $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 REVISIONS No chances shall be made to the scope of work who it prior approval of ' uk—ila Building Division. . v isioys will require a new plan submittal and may ir:c:ude additional plan review fees. FILE COPY Permit Na 1[3 - DO 12_ Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any a, _ = . code or ordnance. Receipt of approved Field • is : « < :. ! 8 City of Tukwila BUILDING DIVISION D i 8-00 l2 SERARtPERMIT Ty_Q1JtEDFOR• erkochanical CIectrical r3 Plumbing Comas Pig City of Tukwila gi-`!Lr" '"O DIVISION 1 JAN 302018 City of Tukwila REVIEWED FOR CODE COMPLIANCE APPROVED Responsibility Schedule )Iv ITEM SUPPLY INSTALL W Demolition Demolition N/A • 0 Li Tenant Vendor CU) 0 0 Fixture Vendor Tenant Vendor U J 0 co 0 H N/A • R VA 1240 SOUTHCENTER MALL SPACE #354 TUKWILA, WA 98188 ABC PHONES OF NORTH CAROLINA, INC. DBA A WIRELESS REVIEWED FOR coDE COMPLIANCE AI Elid.0VIi) JAN 3 0 2018 Concrete Storefront Concrete & Masonry • • Storefront Doors, Frames & Hardware • Rolling Grill • • Storefront Glazing System and Doors • • Awnings/Canopies • • Storefront Facade Patch & Repair • • Exterior Signage • • Finishes Metal Stud Framing • • Gypsum Wall Board • • Acoustic Ceiling Tile • • • Hard Surface Ceiling • • Resilient Flooring (Stockroom) • • Sales Floor Tile (Sales Floor) • • • Vinyl Base (Stockroom) • • Vinyl Base (Sales Floor) Paint & Wall Coverings • • • • STORE TABULATION LIST OF DRAWINGS TABLE 1004.1.2 AREA SQ FT CALCULATION OCCUPANCY LOAD RATIO SALES AREA: 807 SQ FT/60 PERSONS 14 85 % NON -SALES AREA: 133 SQ FT/300 PERSONS 1 15 % TOTALS 940 15 100 % 1 MEANS OF EGRESS REQUIRED 1 MEANS OF EGRESS PROVIDED DWG. NO. DRAWING TITLE City of Tukki' REVISION NO. 9119 ARCHITECTURAL RI. 111 r _ yr ,a • A000 COVER SHEET A001 GENERAL NOTES & ARCHITECTURAL SPECIFICATIONS A002 ARCHITECTURAL SPECIFICATIONS A003 ARCHITECTURAL SPECIFICATIONS A004 ARCHITECTURAL SPECIFICATIONS & LANDLORD NOTES A005 LEASE CONFIRMATION PLAN D101 DEMOLITION PLAN TENANT: verizon 1290-B EAST ARLINGTON BLVD. GREENVILLE, NC 27858 PROJECT PLANNER: WJCA INC. 763 SUSQUEHANNA AVE. FRANKLIN LAKES, NJ 07417 TEL: 201-848-9060 FAX: 201-848-9881 A101 CONSTRUCTION / FIXTURE PLAN A102 REFLECTED CEILING PLAN A103 FINISH PLAN, SCHEDULE, & DETAILS E101 ELECTRICAL PLANS E102 LIGHTING COMCHECK Mechanical HVAC Unit • BUILDING CODE ANALYSIS CONTACTS HVAC Ductwork and Misc. • HVAC Start-up • Thermostat • Plumbing • Sprinklers (incl. submittals, permits, fees, etc.) • • • Furnishings Sales Floor Fixtures • • Apple Displays • • Interior Signage • • Stockroom Shelving & Accessories • • Restroom Accessories (Mirrors, Paper Towel Dispenser, Toilet Paper Dispenser, Grob Bar, etc.) • Fire Extinguishers • • Electrical Electrical Service/Panels/Transformer • Electrical Materials (conduit, boxes, light fixtures, etc.) • • CAT5 Data Cabling • • CAT5 Terminations • • • THESE PLANS ILLUSTRATE PROPOSED INTERIOR TENANT IMPROVEMENTS TO AN EXISTING PREVIOUSLY OCCUPIED SPACE. PLUMBING, MECHANICAL, LIGHTING AND ELECTRICAL WORK ARE NOT INCLUDED IN THESE DOCUMENTS AND MAY REQUIRE SEPARATE PERMITS ONCE THE SCOPE OF WORK HAS BEEN DETERMINED BY THE OWNER'S PROJECT MANAGER. • OCCUPANCY TYPE: MERCANTILE, DISPLAY AND RETAIL SALES OF GOODS WITH ASSOCIATED NON-HARZARDOUS STORAGE. • CONSTRUCTION TYPE: 2B, FULLY SPRINKLERED 2015 IBC W/ STATE AMENDMENTS 2015 UNIFORM PLUMBING CODE W/ STATE AMENDMENTS 2015 IMC W/ STATE AMENDMENTS 2015 IECC W/ STATE AMENDMENTS 2015 IFC W/ STATE AMENDMENTS 2009 ANSI A117.1 ALL WORK SHALL BE DONE IN ACCORDANCE WITH LANDLORD'S CRITERIA AND ALL LOCAL, STATE, AND FEDERAL CODES Company Contacts: Abraham Pack, Store Construction Project Manager (801) 815-2725 a b raha m.pack@victra.com Eric Stultz Director of Store Construction (252) 317-0388 ext. 10112 eric.stultz@victra.com Donna Johnson IT Services Coordinator (252) 317-0388 ext. 10170 donna.johnson®victra.com Architect: David A. Udkow 11881 North 113th Way Scottsdale, AZ 85259 (480) 614-3385 Davidaudkow©cox.net Vendor Contacts: Darcie Strehlow, Thornton Flooring (605) 368-2568 ex. 2124 durcie@thorntoncarpets.com Xavier Burgess, Retail Radio (916) 844-1371 Will Womack, Apple Rock Senior Project Manager (336) 232-4822 will.womack@applerock.com Engineer: Dan R. Rhodes Applied Engineering Group,LTD. 7402 East Broad St. Blacklick, OH 43004 (614) 322-7050 Contact: chris@aegltd.com Mall Contact: Westfield Southcenter 2800 Soutticenter Mall Tukwila, i',,; 98188 (206) 246-0423 Tenant Coordinator: Matt Koenings, Sr Project Manager Westfield National Accounts 855 Market Street San Francisco, CA 94103 (310) 210-9965 MKOENIGS@Westfield.com Project Planner: Renee Michelson WJCA 763 Susquehanna Ave Franklin Lakes,NJ 07417 (201) 848-9060 ext.36 rmichelson@WJCAinc.com ARCHITECT: DAVID A. UDKOW 11881 NORTH 113TH WAY Sp%E,OZ 85259 CITY OF TUKWILA JAN 1 1 2018 PERMIT CENTER IFCT LOCATION: SOUTHCENTER MALL SPACE#354 1240 SOUTHCENTER MALL TUKWILA, WA 98188 ISSUED DRAWING LOG NO. DATE DESCRIPTION 12/27/17 ISSUED FOR LL APPROVAL 01/04/18 ISSUED FOR PERMIT Electrical Flatwire • • Relocate Existing Lighting • • MALL KEY PLAN — NOT TO SCALE Fire Alarm (incl. submittals, permits, fees, etc.) • • Exit Signs and Emergency Lighting • • Sign Circuit, Junction Box, Wiring and Time Clock • • Misc. Misc. Carpentry (not including fixture install) • • Thermal & Moisture Protection • • Permits • • Professional Cleaning • • Construction Barricade (incl. demo and patch/repair) NOTE: INSTALLED BY LANDLORD'S VENDOR AT GC'S EXPENSE • Storefront Barricade Graphics Installation • • Final Occupancy Inspections • • Retail Radio CCN System Burglar Alarm System • • • • • • NORDSTROM mocyt CI 0 0 CI pram AMMO CI WIC ■ p VERIZON WIRELESS (LEVEL 1 OF 3) NOTE: LOCATION OF SPACE #354 IS WITHIN 300' OF PUBLIC RESTROOMS AND DRINKING FOUNTAINS PUBLIC RESTROOMS PROJECT NO: 23706 1 3408 REG!STERED RCHITECT t15114)13 14)aIV DAVID STATE OF WSH NQ1 OFi1 • 000-3408 : 07/03/2019 DRAWING TITLE: COVER SHEET DRAWING NO: A000 GENERAL NOTES DIVISION 01 GENERAL REQUIREMENTS 1. General Contractor is responsible for confirming the existing conditions and existing dimensions of the space prior to submitting his Bid. Owner assumes submitted Bid includes all labor, material, equipment, and proper supervision as necessary to construct the work described and illustrated in these plans and General Contractor will deliver a complete and finished space ready for occupancy, and its intended use, free of any encumbrances. 2. All dimensions are to the finished face and the General Contractor, and/or Subcontractors, must verify the existing dimensions against those noted in these drawings for accuracy. Any found discrepancy must be reported to the Owner's Project Manager for determining the proper course of action, prior to submitting a bid and/or constructing any work. 3. General Contractor may determine that existing work must be replaced or repaired to create a suitable finished condition, and if so determined then associated costs may be listed separately in his Bid or he must verify his concerns with the Owner's Project Manager. 4. All work to be done in accordance to industry standards and/or in accordance with manufacturer's recommendations. 5. While every attempt has been made to completely describe the new work, and its intended finish, it is understood by all that the Generol Contractor, and/or Subcontractor, shall assume full responsibility, and/or consequences, related to their decisions made as a result of not confirming incomplete or unclear information with the Owner's Project Manager or the Architect of Record. 6. No changes to the plans or the work illustrated shall be made without the expressed permission of the A Wireless Project Manager. 7. General Contractor must verify the existing space and at associated elements within comply with the 2010 -Edition of the ADA and/or locally adopted Accessibility Standards. 8. General Contractor shall conduct a "Dark" test of existing Emergency Lighting and verify minimum of 1 -Fc of illumination exists through -out the space and if not shall replace or provide additional battery powered emergency lights as needed. 9. All new finishes shall meet or exceed the required Flammable Rating. 10. General Contractor shall confirm the location of Owner supplied Fixtures prior to installing. ABBREVIATIONS ACM ACT AFF ALU M ALT ARCH AT ASBESTOS CONTAINING MATERIAL ACOUSTIC CEILING TILE ABOVE FINISHED FLOOR ALUMINUM ALTERNATE ARCHITECT ASH RAE AMERICAN SOCIETY OF HEATING, REFRIGERATING & AIR CONDITIONING ENGINEERS ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS ASTM AMERICAN SOCIETY FOR TESTING MATERIALS AWG AMERICAN WIRE GAUGE BD BOARD BL BUILDING LINE BLL BUILDING LIMIT LINE BO BY OTHERS BTM BOTTOM BTU BRITISH THERMAL UNIT CAB. CABINET CLG. CEILING CER CERAMIC CL. CENTERLINE CLR CLEAR COL COLUMN CONC CONCRETE CONST CONSTRUCTION CONT CONTINUOUS COORD COORDINATE CORR CORRIDOR CTR DEPT DTL DF DIA DIAL DI M DIV DN DR(S) DWG ELEV ELECT EN GR EQ EQUIP ETR EWC EXH EX. FT GWB CENTER DEPARTMENT DETAIL DRINKING FOUNTAIN DIAM ETER DIAGONAL DIMENSION DIVISION DOWN DOOR(S) DRAWING ELEVATION ELECTRICAL ENGINEER EQUAL EQUIPMENT EXISTING TO REMAIN ELECTRIC WATER COOLER EXHAUST EXISTING FEET GYPSUM WALLBOARD INFO INSUL INT L LAV LB LH LH R LIN LT MFR MATL MAX MECH MED M DF M EZZ MTL MIN MISC NIC NO NTS OA OC OFF PERF PERM PERP PH PLAM PLYWD PNL POL POS PT PTG PR. R REF RH PHR REQ'D S/SS) SECT SEP INFORMATION INSULATE, INSULATING, INTERIOR LENGTH LAVATORY POUND LEFT HAN D LEFT HAND REVERSE LINEAR LIGHT MANUFACTURER MATER IAL MAXIMUM MECHANICAL MEDIUM MEDIUM -DENSITY FIBREBOARD MEZZANINE M ETAL MINIMUM MISCELLANEOUS NOT IN CONTRACT NUMBER NOT TO SCALE OVERALL ON CENTER OFFICE PERFORATED PERMANENT PERPENDICULAR PHASE PLASTIC LAMINATE PLYWOOD PANEL POLISHED POSITIVE PAINT PAINTING PAI R RADIUS REFRIGERATOR RIGHTHAND RIGHT HAND REVERSE REQUIRED ROOM(S) STAINLESS STEEL SECTION SEPARATE SPEC(S) SPECI ICATION(S) SP KR SPEAKER SPKLR SPRINKLER SQ SQUARE SV..II.F. SENIOREIN FIELD A. GENERAL CONDITIONS OF THE CONTRACT: 1. GENERAL CONDITIONS OF THE CONTRACT ARE HEREBY MADE PART OF THIS SPECIFICATION THE SAME AS IF BOUND HEREIN. 2. THE GENERAL CONDITIONS, INCLUDING MODIFICATIONS AND SPECIAL CONDITIONS HEREIN SHALL BECOME A PART OF THE CONTRACT AND SHALL APPLY TO THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS. 3. THE GENERAL REQUIREMENTS & GENERAL CONDITIONS ARE HEREBY MADE A PART OF AND SHALL APPLY TO THE WORK OF EVERY SECTION AND SUB -SECTION OF THESE SPECIFICATIONS. 4. THE AGREEMENT WILL ALSO EXPAND THIS STATED SCOPE. ANY ADDITIONAL REQUIREMENTS ADDRESSED IN THE AGREEMENT ARE PART OF THE GENERAL CONDITIONS OF THIS CONTRACT AND SCOPE. B. SCOPE: 1. BE RESPONSIBLE FOR A COMPLETE AND OPERATIONAL PROJECT INCLUDING, BUT NOT LIMITED TO ALL FINISHES, MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION. 2. WORK OF THE CONTRACT INCLUDES FURNISHING OF ALL LABOR, MATERIALS, APPLIANCES, TRANSPORTATION AND SERVICES REQUIRED FOR SATISFACTORY CONSTRUCTION OF THIS PROJECT. 3. VERIFY EXISTING CONDITIONS THAT AFFECT ALL ALTERATIONS ADJUSTMENTS, ETC. TO DELIVER A COMPLETED PROJECT THAT CONFORMS TO THE CONTRACT DRAWINGS, SPECIFICATIONS AND CODE COMPLIANCE. REPORT FINDINGS TO PROJECT REPRESENTATIVE PRIOR TO INSTALLATION. 4. VERIFY SETBACKS, AND/OR EASEMENTS, EXISTING UTILITIES, AND ANY UNDERGROUND OR SURFACE STRUCTURE OR CONDITIONS PRIOR TO COMMENCING THE WORK. REPORT FINDINGS TO PROJECT REPRESENTATIVE PRIOR TO INSTALLATION. 5. REQUESTS FOR INFORMATION MUST BE MADE IN WRITING TO THE DESIGNATED PROJECT REPRESENTATIVE. WRITTEN INQUIRIES SHOULD REASONABLY IDENTIFY THE INFORMATION NEEDED WHEN INFORMATION IS NEEDED, AND SHOULD INDICATE A MAILING ADDRESS, PHONE NUMBER, OR OTHER MEANS TO CONTACT SENDER REGARDING THE REQUEST. C. SCHEDULING AND COORDINATION: 1. COORDINATE WORK WITH WORK OF OTHER TRADES, THE LANDLORD'S FORCES, OTHER TENANT CONTRACTORS, AND TENANT STORE OPERATIONS IN ORDER TO AVOID CONFLICTS AND EXPEDITE THE COMPLETION OF THE PROJECT. 2. FURNISH LABOR, MATERIALS, EQUIPMENT AND APPLIANCES NECESSARY TO COMPLETE THE INSTALLATION OF ALL ITEMS FURNISHED BY OTHERS. 3. COORDINATE ALL DEVICE LOCATIONS WITH EXISTING CONDITIONS AND WITH PROJECT DESIGN INTENT - CLARIFY INTENT WITH PROJECT REPRESENTATIVE. ALL LIFE SAFETY DEVICE LOCATIONS ARE 10 BE REVIEWED WIIH PROJECT REPRESENTATIVE FOR DESIGN INTENT, BUT FINAL LOCATIONS ARE 10 UrRDINATED WITH INSPECTOR OR OTHER AUTHORITIES HAVING JURISDICTION. 4. REPORT ALL CONFLICTS IN THE CONSTRUCTION DRAWINGS TO THE PROJECT REPRESENTATIVE IMMEDIATELY. 5. VISIT THE SITE AND VERIFY ALL EXISTING CONDITIONS. BRING ANY DEVIATIONS TO THE ATTENTION OF THE PROJECT REPRESS JTATIVE PRIOR TO INSTALLATION.. 6. ANY WORK REQUIRED TO BE COMPLETED DURING NON -BUSINESS HOURS SHALL BE INCLUDED IN THE BID. 7. COORDINATE AND SCHEDULE ALL "OFF" HOUR WORK WITH LOCAL JURISDICTION AND/OR BUILDING MANAGER 8. REFER TO THE RESPONSIBILITY SCHEDULE TO CLARIFY RESPONSIBILITIES FOR SPECIFIED WORK. D. SEPARATE CONTRACTORS: THE PROJECT WILL HAVE VARIOUS SEPARATE CONTRACTORS AND/ OR OFI PROVIDERS. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING WITH THESE PARTIES T0: 1. SCHEDULE OFI DELIVERY AND/OR WORK, INCLUDING SCHEDULING THE DELIVERY OF MATERIALS, THE SCHEDULING OF FIELD WORK AND THE QUALITY OF EXECUTED WORK. 2. COORDINATING THE WORK OF SEPARATE CONTRACTORS AND/OR OFI PROVIDERS WITH THE GENERAL CONTRACTOR'S RESOURCES AS WELL AS WITH THE RESOURCES OF OTHER SEPARATE CONTRACTORS AND/OR OFI PROVIDERS. 3. ENSURING TIMELINE IS MET FOR THIS WORK ON BEHALF OF THE SEPARATE CONTRACTORS AND/ OR OFI PROVIDERS AND REPORTING THIS PROGRESS TO THE TENANT D. A REGULAR BASIS, AS OUTLINED BY THE PROJECT CONSTRUCTION SCHEDULE. 4. COORDINATE COMPLETION AND COMMISSIONING (WHEN REQUIRED) FOR ALL SYSTEMS, EQUIPMENT AND ASSEMBLIES PROVIDED BY SEPARATE CONTRACTORS OR 03 PROVIDERS. E. PROJECT MANAGEMENT AND SUPERVISION: 1. PROVIDE A FULL TIME, QUALIFIED SUPERVISOR ON THE JOB SITE. 2. PROVIDE A JOB SITE TELEPHONE AND COMPUTER DURING THE CONSTRUCTION PERIOD. NOTIFY PROJECT REPRESENTATIVE IMMEDIATELY OF CONTACT NUMBERS. 3. RFIS ARE TO BE SUBMITTED IN WRITING TO THE PROJECT REPRESENTATIVE WITH DATE SUBMITTED AND DATE THAT A RESPONSE IS REQUIRED. ALLOW MINIMUM OF FIVE (5) DAYS FOR ANY RESPONSE. F. PERMITS: 1. OBTAIN AND PAY FOR ALL PERMITS AND INSPECTIONS REQUIRED, UNLESS SPECIFIED OTHERWISE. G. UTILITIES: 1. PROVIDE ALL TEMPORARY UTILITIES (INCLUDING, BUT NOT LIMITED T0, WATER, SEWAGE, ELECTRICAL POWER, FUEL AND TELEPHONES) AND THE COSTS ASSOCIATED WITH THESE. 2. PROVIDE THE PROJECT REPRESENTATIVE WITH ALL UTILITY COMPANY NAMES, NUMBERS, CONTACTS AND ACCOUNT NUMBERS (OWNER WILL TRANSFER ACCOUNTS TO THEIR NAME AT TURNOVER). H. TESTS AND INSPECTIONS: 1. ALL TESTS AND INSPECTIONS, OF ANY KIND, REQUIRED, AND WHICH INVOLVE EXPENSE, SHALL BE PAID BY THE CONTRACTOR AT NO ADDITIONAL EXPENSE. PROVIDE PROJECT REPRESENTATIVE WITH LIST AND SCHEDULE OF ANTICIPATED TESTS. I. PROTECTION OF WORK IN PLACE: 1. ALL WORK IN PLACE SHALL BE ENCLOSED WITH ADEQUATE PROTECTION. PERMANENT OPENINGS USED AS THOROUGHFARES FOR THE INTRODUCTION OF WORK AND MATERIALS TO THE STRUCTURE SHALL HAVE HEADS, JAMBS AND SILLS WELL BLOCKED AND BOARDED. 2. PROTECT ALL NEW WORK, FURNISHINGS, AND EQUIPMENT AT ALL TIMES. ANY DAMAGE THAT OCCURS AS A RESULT OF CONSTRUCTION IS TO BE REPAIRED TO LIKE NEW CONDITION. 3. ERECT A TEMPORARY BARRICADE AT THE STOREFRONT ONLY IF REQUIRED BY THE LOCAL JURISDICTION AND/OR ANOTHER AUTHORITY HAVING JURISDICTION. REVIEWED FOR CODE COMPLIANCE APPROVED JAN 3 0 2018 LRI City o r Tukwila M DING DM `:,'' • ' 1 TENANT: verizon 1290-B EAST ARLINGTON BLVD. GREENVILLE, NC 27858 PROJECT PLANNER: WJCA INC. 763 SUSQUEHANNA AVE. FRANKLIN LAKES, NJ 07417 TEL: 201-848-9060 FAX: 201-848-9881 ARCHITECT: DAVID A. UDKOW 11881 NORTH 113TH WAY SD LE 3Z 85259 CITY OF TUKWILA JAN 1 1 2018 PERMIT CENTER PROJECT LOCATION: SOUTHCENTER MALL SPACE#354 1240 SOUTHCENTER MALL TUKWILA, WA 98188 ISSUED DRAWING LOG NO. DATE DESCRIPTION 12/27/17 ISSUED FOR LL APPROVAL 01/04/18 ISSUED FOR PERMIT PROJECT NO: 23706 3408 REGISTERED 0' °RCHITEC DAVID A. UDKOW STATE OF WASHINGTON LIC. #: 208-00-000-3408 EXP. DATE: 07/03/2019 DRAWING TITLE: GENERAL NOTES & ARCHITECTURAL SPECIFICATIONS DRAWING NO: A001 DIVISION 01 GENERAL REQUIREMENTS (CONTINUED) TENANT: J. GUARANTEE: 1. A WRITTEN GUARANTEE SHALL BE PROVIDED ON ALL LABOR AND MATERIALS FOR A PERIOD OF NO LESS THAN ONE YEAR FROM THE DATE OF THE S. SAMPLES: REQUIRED SAMPLE TO THE PROJECT REPRESENTATIVE FOR APPROVAL. Vet'IZOrl SUBSTANTIAL COMPLETION OF THE PROJECT. 2. THE PROJECT REPRESENTATIVE SIGNATURE AND DATE OF ACCEPTANCE IS REQUIRED IN ORDER TO ACTIVATE THIS GUARANTEE. THIS GUARANTEE SHALL COVER ALL OF THE GENERAL AND SUBCONTRACTOR'S WORK. 3. ALL DEFECTS DISCOVERED DURING THIS GUARANTEE PERIOD SHALL BE REPAIRED TO THE OWNER/TENANT'S SATISFACTION AT CONTRACTOR'S EXPENSE AT NO COST TO THE OWNER/TENANT. 4. FURNISH THE FOLLOWING UPON COMPLETION OF WORK: 1. SUBMIT MINIMUM THREE OF EACH 2. INCLUDE IDENTIFICATION ON EACH SAMPLE WITH FULL PROJECT INFORMATION. 3. PROVIDE SAMPLES FOR ITEMS INDICATED HEREIN, PER THE CONSTRUCTION DOCUMENTS, OR UPON REQUEST BY THE PROJECT REPRESENTATIVE. T. INSURANCE: INSURANCE POLICIES REQUIRED AND IN AMOUNTS AS SET FORTH HEREIN. WORK 1290-B EAST ARLINGTON BLVD. GREENVILLE, NC 27858 a. CERTIFICATE OF OCCUPANCY. b. GENERAL CONTRACTOR'S AFFIDAVIT THAT THE PROJECT WAS BUILT PER THE CONSTRUCTION DOCUMENTS. GENERAL CONTRACTOR'S RELEASE OF WAIVER OF LIEN. 1. SECURE, PAY FOR AND MAINTAIN ALL SHALL NOT COMMENCE UNTIL ALL REQUIRED INSURANCE HAS BEEN OBTAINED AND CERTIFICATES OF SUCH INSURANCE HAVE BEEN DELIVERED TO THE REQUIRED PARTIES. 2. BUILDING OWNER MUST BE NAMED AS "ADDITIONAL INSURED". CERTIFICATE OF INSURAN SNALL-COVER WDRA PROJECT PLANNER: c. d. AN EXECUTED AND ACKNOWLEDGED RELEASE OF MECHANIC'S LIENS WITH RESPECT TO DEMISED PREMISES EXECUTED BY THE TENANT'S GENERAL CONTRACTOR AND EVERY SUB CONTRACTOR AND SUPPLIER OF LABOR AND MATERIALS ENGAGED IN TENANT'S WORK HIRED BY THE GENERAL CONTRACTOR. e. ELECTRICAL INSPECTION CERTIFICATE f. UNDERWRITER'S APPROVAL CERTIFICATE FOR THE ELECTRICAL WORK. g. HVAC WARRANTY. h. OPERATION MANUALS FOR ALL MECHANICAL AND ELECTRICAL EQUIPMENT. i. ROOFING SYSTEM - SUBMIT COPIES OF THE MANUFACTURER'S FINAL INSPECTION PRIOR TO THE ISSUANCE OF THE MANUFACTURER'S PERFORMED BY CONTRACTOR, EACH SUBCONTRACTOR AND ALL SUPPLIERS. REVIEWED FOR 3. THE MINIMUM COVERAGE AND LIMITS OF LIABILITY ARE AS FOLLOWS: a. WORKMEN'S COMPENSATION INSURANCE INCLUDING PAYMENT TO THE CODE COMPLIANCE EMPLOYEES OF THE CONTRACTOR, COMPENSATION PROVIDED BY THE APPROVED WORKMEN'S COMPENSATION LAWS OF THE STATE IN WHICH THE WORK 3 tp IS BEING PERFORMED, WITH LIMITS OF NOT LESS THAN 82,000,000. JAN 0 �G Itl b. CONTRACTOR'S PUBLIC LIABILITY INSURANCE, HAVING LIMITS OF NOT LESS THAN 82,000,000. c. CONTRACTOR'S PROTECTIVE LIABILITY INSURANCE, HAVING LIMITS OF NOT LESS THAN 82,000,000.FAX: d. GENERAL THIRD PARTY PROPERTY DAMAGE INSURANCE, HAVING City of Tukwila 763 SUSQUEHANNAWJCA INC.AVE. FRANKLIN LAKES, NJ 07417 TEL: 201-848-9060 201-848-9881 WARRANTY. j. MARKUP CONSTRUCTION DRAWINGS IDENTIFYING DEVIATIONS. LIMITS OF NOT LESS THAN 82,000,000. BUILD' 1, III • ►- ARCHITECT: K. PAYMENT AND WAIVER OF LIENS: FOR TMHIS PROORCT AND ONLYMAFORIAOPAYMENTSIO SUBCONTRACTORS AND MATERIAL SUPPLIERS, 1. PAYMENTSNDMADE FOR THIS PROJECTPIARE BE ALLOCATEDTO AND AGENTS AUTHORIZED BY SPECIFIC CONTRACTORS TO PERFORM WORK OR SUPPLY MATERIALS TO THIS PROJECT. 2. SUBMIT PARTIAL WAIVERS OF LIEN FOR WORK INCLUDING SUBCONTRACTORS AND MATERIAL SUPPLIERS. 3. THE FINAL 10% RETENTION ON THIS PROJECT MUST INCLUDE SIGNED AND EXECUTED WAIVERS OF LIEN INDICATING 100% COMPLETION AND 100% PAYMENT IN FULL BY ALL SUBCONTRACTORS AND MATERIAL SUPPLIERS. 4. PROVIDE A "SWORN STATEMENT" LISTING ALL SUBCONTRACTORS AND CONTRACT VALUE. 5. AT PROJECT START, PROVIDE A LIST OF ALL SUBCONTRACTORS, INCLUDING ADDRESS AND PHONE NUMBER TO THE TENANT'S REPRESENTATIVE. AT PROJECT COMPLETION, SUBMIT FINAL AND UPDATED LIST OF SAME. 6. REFER TO THE CONTRACT FOR PAYMENT TERMS. L. TRASH REMOVAL: 1. PROVIDE FOR REMOVAL,TRANSPORT AND DISPOSAL OF ALL TRASH, RUBBISH AND SURPLUS MATERIALS RESULTING FROM CONSTRUCTION OF THE PROJECT. U. INDEMNIFICATION: 1. TO THE FULLEST EXTENT PERMITTED BY LAW, INDEMNIFY AND HOLD HARMLESS THE OWNER, AND ARCHITECT AND THEIR AGENTS AND ATTORNEYS FEES LARSENGS FROM SU HLIMITED PROVIDED THAT ANYNOT OF THE WORK,EXPENSES, THEDAMAGES, PERFORMANCELOSSES ESULTING FROMCLAIMS, ORAGAINST OUT OFAND CLAIM, DAMAGE, LOSS OR EXPENSE IS ATTRIBUTABLE TO BODILY INJURY, SICKNESS, DISEASE OR DEATH, OR TO INJURY OR TO DESTRUCTION OF TANGIBLE PROPERTY (OTHER THAN THE WORK ITSELF) INCLUDING THE LOSS OF USE RESULTING THEREFROM. V. USE OF CONSTRUCTION DOCUMENTS & COMPUTER-AIDED CONTRACT DESIGN DOCUMENTS: 1. DRAWINGS ARE TO BE USED SOLELY FOR THE PROJECT INDICATED. 2. ARCHITECT WILL RETAIN OWNERSHIP OF THE DOCUMENTS AND MAY ALLOW A SEPARATE LICENSEE AGREEMENT. 3. IN THE EVENT THAT THE GENERAL CONTRACTOR OR ANY SUBCONTRACTORS REQUEST COMPUTER AIDED BACKGROUND DRAWINGS COPIES OF THESE DRAWINGS MAY BE PROVIDED SUBJECT TO THE FOLLOWING CONDITIONS: a. A SEPARATE AGREEMENT TITLED AIA C106-2007 MUST BE SIGNED BY THE CONTRACTOR/SUBCONTRACTOR BEFORE THE A `tCOENMKOW CO LE' 59WAY CIT Q JAN 11 205 PERMIT CENTER M. CLEAN UP: 1. MAINTAIN CLEAN JOB SITE DURING ENTIRE PROJECT. 2. REMOVE ALL PROTECTIVE COVERINGS FROM ALL CONSTRUCTION MATERIALS AND FINISHES AS DIRECTED BY THE PROJECT REPRESENTATIVE. 3. HVAC FILTERS TO BE CHANGED FOLLOWING THE FINAL CLEANING. DATE OF FILTER CHANGE TO BE HANDWRITTEN AND VISIBLE ON EACH FILTER. 4. THE COMPLETED PROJECT IS TO BE CLEAN AND READY FOR OCCUPANCY N. THE TERM "OR EQUAL": TRANSFER OF THE FILES. W. MISSING/DAMAGED FREIGHT (OWNER/TENANT FURNISHED MATERIALS): 1. OPEN BOXES/CARTONS WITH OBVIOUS DAMAGE IMMEDIATELY UPON DELIVER AND INSPECT FOR DAMAGE. 2. INSPECT FREIGHT BEFORE SIGNING THE FREIGHT BILL, NOTE SPECIFICALLY THE ITEM(S) MISSING/DAMAGED. 3. AFTER THE PROBLEM IS NOTED ON THE FREIGHT BILL, HAVE CARRIER'S DRIVER ALSO SIGN IN ORDER TO VERIFY THAT BOTH PARTIES AGREE TO THE EXTENT OF THE DAMAGE. 4. WHEN DAMAGE IS DISCOVERED UPON UNPACKING THE FREIGHT, INSPECT ALL PACKING FOR SIGNS OF DAMAGE OR ABUSE. FREIGHTTHEROL ISC TO BE NOTED WITH THE CIFIED DAMAGE. PROJECT LO i7iviv. SOUTHCENTER MALL SPACE#354 1240 SOUTHCENTER MALL TUKWILA, WA 98188 1. WHEREVER THE TERM "OR EQUAL" IS USED, IT SHALL MEAN EQUAL PRODUCT AS APPROVED IN WRITING BY THE PROJECT REPRESENTATIVE, NO EXCEPTIONS. 48SP ONTHE 5. CONTACT THE PROJECT REPRESENTATIVE WITHIN 48 HOURS OF TAKING RECEIPT OF MATERIALS TO INFORM THEM OF ANY ISSUED DRAWING LOG LOSS. EMAIL ALL REQUIRED DOCUMENTATION TO PROJECT REPRESENTATIVE. 0. QUALITY OF WORK: 6. IF CONTRACTOR FAILS TO FOLLOW THIS PROCEDURE, CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS RELATED TO NO. DATE DESCRIPTION 1. ALL WORK SHALL BE PERFORMED IN A SAFE AND WORKMANLIKE MANNER IN ACCORDANCE WITH ACCEPTED CONSTRUCTION STANDARDS AND 0.S.H.A. REQUIREMENTS. THE REPLACEMENT OF MISSING/ DAMAGED OWNER FURNISHED MATERIALS. 12/27/17 ISSUED FOR LL APPROVAL 2. ALL CONSTRUCTION SHALL BE IN STRICT ACCORDANCE WITH THE PLANS UNLESS A VARIANCE IS APPROVED BY THE PROJECT REPRESENTATIVE AND ALL AUTHORITIES HAVING JURISDICTION. Y. PROJECT CLOSEOUT 1. REFER TO AGREEMENT FOR ADDITIONAL REQUIREMENTS. 01/04/18 ISSUED FOR PERMIT 3. ALL EQUIPMENT AND MATERIALS UNDER THE CONTRACT ARE TO BE NEW UNLESS OTHERWISE SPECIFIED IN THE PLANS. 2. OBTAIN SIGN -OFFS FROM ALL AUTHORITIES HAVING JURISDICTION. 3. COORDINATE SUBSTANTIAL AND FINAL COMPLETION EFFORTS WITH PROJECT REPRESENTATIVE. P. CODE COMPLIANCE: 1. VERIFY ALL WORK IS IN COMPLIANCE WITH ALL CODES, ORDINANCES, AND REGULATIONS OF ALL CONSTITUTED PUBLIC AUTHORITIES HAVING JURISDICTION. THIS 4. DELIVER COMPLETED WORK AND PROVIDE ALL REQUIRED DOCUMENTATION TO PROJECT REPRESENTATIVE. INCLUDES BUT IS NOT LIMITED TO LOCAL BUILDING CODE REQUIREMENTS, FIRE DEPARTMENT REGULATIONS, UTILITY COMPANY REQUIREMENTS, 0.S.H.A., AND THE BEST TRADE PRACTICES. Q. DIMENSIONS: 1. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE MEASURED FROM FINISHED FACE TO FINISHED FACE OF MATERIALS, OR LEASE LINE. PROJECT NO: DIVISION 02 EXISTING CONDITIONS 23706 2. VERIFY ALL PROPOSED DIMENSIONS WITH FIELD CONDITIONS. ADVISE THE PROJECT REPRESENTATIVE OF ANY DISCREPANCY BETWEEN THE DRAWINGS AND ACTUAL JOB CONDITIONS PRIOR TO INSTALLING THE WORK. FAILURE TO DO SO SHALL PLACE FULL RESPONSIBILITY FOR ANY ERRORS UPON THE CONTRACTOR. 3. ALL DIMENSIONS SHOWN SHALL BE CONSIDERED HOLD DIMENSIONS UNLESS NOTED OTHERWISE.. 4. ALL ANGLES SHALL BE 90 OR 45 DEGREES UNLESS OTHERWISE NOTED IN THE CONSTRUCTION DOCUMENTS. 5. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALE. DO NOT SCALE. A. DEMOLITION: 1. VISIT THE SITE PRIOR TO BID SUBMISSION AND VERIFY ALL EXISTING CONDITIONS (I.E., OVERALL DIMENSIONS, CONDITION OF CONCRETE SLAB, LOCATION OF SERVICES, STRUCTURE, CLEARANCES, ETC.) AGAINST THE PROPOSED WORK. REPORT ANY DISCREPANCIES, OMISSIONS OR OBSTRUCTIONS THAT WILL AFFECT DRAWING TITLE: 340$ REGI T RED ARCHITEC ARCHITECTURAL R. SHOP DRAWINGS & SUBMITTALS: 1. SUBMIT THE NUMBER OF OPAQUE REPRODUCTIONS WHICH CONTRACTOR REQUIRES TO HAVE RETURNED, PLUS TWO COPIES, TO THE PROJECT REPRESENTATIVE FOR APPROVAL. 3. MARK2. SUBMITTALS EACH COPY TO IDENTIFY APPLICABLE PRODUCTS, MODELS, OPTIONS, AROGRESS ND F TOTHER HE RDATA. SUPPLEMENT MANUFACTURER'S STANDARD DATA TO PROVIDE INFORMATION SPECIFIC TO THIS PROJECT. THE LAYOUT OR DESIGN IMMEDIATELY TO THE PROJECT REPRESENTATIVE. 2. ALL CONDITIONS AND DIMENSIONS SHOWN ARE FOR REFERENCE ONLY AND MUST BE FIELD VERIFIED. 3. UPON COMPLETION OF DEMOLITION, ALL CONDITIONS AND DIMENSIONS ARE TO BE SED WORK. REPORT ANY DISCREPANCIES IMMEDIATELYK. VERIFIED AGAIN FOR CTO THEES ' PROJECT REPRNST THE ESENTATIVE 4. THIS PORTION OF THE WORK INCLUDES ALL LABOR, MATERIALS AND SERVICES 4rili Ill lij i `SPECIFICATIONS I ` TIO A. UDKO'« .�SjATEOFWASh'J!i�'�zo:Ij 4. INDICATE SPECIAL UTILITY AND ELECTRICAL CHARACTERISTICS, UTILITY CONNECTION REQUIREMENTS, AND LOCATION OF UTILITY OUTLETS FOR SERVICE FOR FUNCTIONAL EQUIPMENT AND APPLIANCES. 5. IDENTIFY VARIATIONS FROM CONTRACT DOCUMENTS AND PRODUCT OR SYSTEM LIMITATIONS WHICH MAY AFFECT THE CONSTRUCTION PROGRESS. 6. ONLY PROVIDE SHOP DRAWINGS AND SUBMITTALS FOR SUBSTITUTIONS, DEVIATIONS, OR ITEMS INDICATED HEREIN, PER THE CONSTRUCTION DOCUMENTS, OR UPON REQUEST BY THE PROJECT REPRESENTATIVE. NECESSARY FOR AND REASONABLY INCIDENTAL TO COMPLETE ALL DISMANTLING, DEMOLITION, AND SALVAGE AS SHOWN AND NOTED ON THE DRAWINGS AND SPECIFIED HEREIN. 5. PROTECT ALL AREAS NOT INCLUDED IN THE WORK. ANY DAMAGE THAT OCCURS AS A RESULT OF THE WORK SHALL BE REPAIRED TO A LIKE NEW CONDITION AT G.C. EXPENSE. DRAWING NO: LIC. #: 208-00-000-3408 A002 EXP. DATE: 07/03/2019 DIVISION 02 EXISTING CONDITIONS (CONTINUED) DIVISION 07 THERMAL & MOISTURE PROTECTION TENANT: verizori NOTED. 6. NO 7. REFERTTOATIONS TO THE ARCHITECCTURALEXISTING DRAWINGSTANDTERAL LECTRICALERS ARE DRAWNG FOR WED SCOPELOFSNEWEWORK. 8. MAINTAIN AND/OR REPAIR ALL FIRE RATED ASSEMBLIES AND SEPARATIONS (PARTITION, FLOOR, CEILING, OR BETWEEN ADJACENT SPACES ETC.) REQUIRED BY CODE OR REGULATION. 9. NOTIFY THE PROJECT REPRESENTATIVE OF ANY UNFORESEEN HAZARD OF ANY KIND BEFORE DEMOLITION IS COMPLETE. THE REMOVAL AND/0R HANDLING OF HAZARDOUS MATERIALS (E.G. - A.C.M.) IS NOT PART OF THIS WORK. IF ANY DISTURBANCE OF HAZARDOUS MATERIAL IS ANTICIPATED BY THIS WORK, AUTHORITIES MUST BE NOTIFIED AND PRESCRIBED PROCEDURES MUST BE FOLLOWED. 10.DISCONNECTION OF SERVICES: a. EXISTING SERVICES THAT WILL BE DISRUPTED BY CONSTRUCTION WORK SHALL BE RE-ROUTED AS NECESSARY TO PROVIDE TEMPORARY CONTINUATION OF SERVICE. b. DISCONNECTED SERVICES SHALL BE PLUGGED AND SEALED IN AN APPROVED MANNER. c. ANY DISCONNECTED SERVICES INTERFERING WITH THE NEW CONSTRUCTION SHALL BE REMOVED ONLY TO THE EXTENT THAT THEY DO NOT INTERFERE WITH NEW CONSTRUCTION. d. SPRINKLER SHUT DOWN SHALL BE COORDINATED WITH THE BUILDING MANAGEMENT PRIOR TO EXECUTION OF WORK. 11.ABANDONED ELECTRICAL WIRING: a. CONDUITS AND OTHER UTILITIES ENCOUNTERED IN THE PROGRESS OF THE DEMOLITION THAT ARE TO BE ABANDONED SHALL BE DISCONNECTED AND THE ENDS PLUGGED IN AN APPROVED MANNER. ANY ABANDONED UTILITIES INTERFERING WITH WORK UNDER THIS CONTRACT SHALL BE REMOVED ONLY TO THE EXTENT THAT THEY DO NOT INTERFERE WITH NEW CONSTRUCTION. 12.SALVAGED MATERIALS AND EQUIPMENT: a. REFER TO THE PLANS FOR ITEMS TO BE SALVAGED. CONSULT WITH THE PROJECT REPRESENTATIVE PRIOR TO THE DISPOSAL OF MATERIALS AND EQUIPMENT. b. PACKAGE, PROTECT AND STORE SALVAGED ITEMS FOR FUTURE USE. 13.DISPOSAL OF NON -SALVAGED MATERIALS AND EQUIPMENT: a. ALL MATERIALS AND EQUIPMENT NOT SCHEDULED TO BE SALVAGED, INCLUDING DEBRIS, SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE DISPOSED OF IN A LEGAL MANNER. b. LOCATION OF DISPOSAL AREA AND LENGTH OF HAUL SHALL BE CONTRACTOR'S RESPONSIBILITY. A. 1. PROVIDE RISTALL 6 MIL. POLYETHYLENE BELOW ALL REQUIRED PATCH AREAS AT AND THAT RECEIVE BATT INSULATION. B. ELASTOMERIC CRACK BRIDGING: 1. PROVIDE AND INSTALL ELASTOMERIC CRACK BRIDGING AS MANUFACTURED BY NATIONAL APPROVED EQUAL. C. BATT INSULATION: 1. PROVIDE AND INSTALL MINIMUM R-13 FRICTION FIT, FULL BATT INSULATION AS MANUFACTURED INDICATED IN THE DRAWINGS. D. ACOUSTICAL INSULATION: 1. PROVIDE AND INSTALL ASTM C665, UNFACED, 0.32 K -VALUE, WIDTHS TO COORDINATE SHOWN, FILL CAVITY. E. SEALANTS: 1. PROVIDE AND INSTALL THE SEALANTS REQUIRED IN CONJUNCTION WITH ROOFING, WATERPROOFING, CARPENTRY, ETC. 2. COLOR TO APPROXIMATE ADJACENT SURFACES, UNLESS DIRECTED OTHERWISE. G. FIRESTOPPING: 1. PROVIDE AND INSTALL UL TESTED FIRESTOPPING ASSEMBLIES AS ARE APPLICABLE FOR ASSEMBLIES, PROVIDE FIRESTOPPING ASSEMBLIES AS RECOMMENDED BY THE FIRESTOPPING BY AUTHORITIES HAVING JURISDICTION. 2. PROVIDE FIRESTOPPING MATERIALS OF THE THICKNESS REQUIRED TO MAINTAIN THE INSTALLED. 3. STRICTLY MATCH UL TESTED ASSEMBLIES. 4. INSTALL FIRESTOPPING WITHOUT GAPS AND VOIDS OF ANY KIND. 5. INSPECT FIRESTOPPING WORK AND REPAIR OR REPLACE WORK WHICH HAS BEEN DAMAGED, OR ENCLOSED. 6. PROVIDE ANCHORAGE ACCESSORIES AND OTHER COMPONENTS AS NEEDED TO PROVIDE TESTED ASSEMBLIES. H. FIRE CAULKING: 1. ALL SLEEVES, OPENINGS, ETC. THROUGH FIRE RATED WALLS AND FLOORS SHALL BE RATED SEALANTS OR EQUAL BY HILTI AFTER INSTALLATION SO AS TO RETAIN THE FIRE I. FIREPROOFING: 1. PROVIDE AND INSTALL UL TESTED FIREPROOFING ASSEMBLIES AS ARE APPLICABLE HAVING JURISDICTION. 2. PROVIDE FIREPROOFING MATERIALS OF THE THICKNESS AND DENSITY REQUIRED TO L TESTED ASSEMBLIES. 4. N3. TSPECTYEXISTINGMATCH UFIREPROOFNG WORK AND REPAIR OR REPLACE WORK WHICH HAS 5. PROVIDE ANCHORAGE ACCESSORIES AND OTHER COMPONENTS AS NEEDED TO PROVIDE TESTED ASSEMBLIES. J. EXPANSION JOINTS/EXPANSION JOINT COVERS 1. PROVIDE EXPANSION JOINTS, AS REQUIRED FOR APPLICATION, WITH ELASTOMERIC FILLER 2. INSTALL PER PLANS AND MANUFACTURER'S RECOMMENDATIONS. SLAB ON GRADE CONDITIONS AND 4 MIL. POLYETHYLENE APPLIED CONSTRUCTION PRODUCTS, INC. 800-633-4622 BY OWENS-CORNING FIBERGLASS OR EQUAL WITH FRAMING FOR FRICTION FILL, THICKNESS SHOWN FIREPROOFING, FIRESTOPPING, DOOR EACH CONDITION ENCOUNTERED. IN THE ABSENCE SYSTEM MANUFACTURER'S STAFF ENGINEERS FIRE RATINGS OF THE ASSEMBLIES INTO WHICH THE DISTURBED, OR REMOVED BEFORE FIRESTOPPING COMPLETE, EFFECTIVE FIRESTOPPING SYSTEMS COMPLYING FIRE SEALED WITH CALCIUM SILICATE, SILICONE "RN" RATING. FOR EACH CONDITION ENCOUNTERED AND AS APPROVED ACHIEVE THE REQUIRED FIRE RATINGS. BEEN DAMAGED, DISTURBED, OR REMOVED. COMPLETE, EFFECTIVE FIREPROOFING SYSTEMS COMPLYING TO MATCH ADJACENT FINISH AS MANUFACTURED AT WALLS OR WHERE OR IF NOT FRAMES, & OF TESTED AND AS APPROVED MATERIALS ARE IS CONCEALED WITH UL FOAM, "3M' FIRE BY AUTHORITIES WITH UL BY BALCO INC.. 1290-B EAST ARLINGTON BLVD. GREENVILLE, NC 27858 PROJECT PLANNER: WJCA INC. 763 SUSQUEHANNA AVE. FRANKLIN LAKES, NJ 07417 TEL: 201-848-9060 FAX: 201-848-9881 ARCHITECT: DAVID A. UDKOW 11881 NORTH 113TH WAY SC SDALE,AZ85259 NE . C I VE D CITY OF TUKWILA JAN 2018 PERMIT CENTER DIVISION 03 CONCRETE A. PATCHING (WHEN REQUIRED) 1. INSTALL MINIMUM 3000 PSI CONCRETE FILLER AND PATCHING WHERE EXISTING SLAB HAS BEEN REMOVED FOR UNDER SLAB CONDUITS, ETC. DIVISION 04 MASONRY A. NO WORK UNDER THIS SECTION UNLESS REQUIRED FOR PROPER CUTTING AND REPAIR OF BUILDING SHELL. IN THIS EVENT ALL WORK SHALL BE PERFORMED TO THE HIGHEST LEVELS OF QUALITY AND CRAFTSMANSHIP AND SHALL BE COORDINATED WITH LANDLORD'S REPRESENTATIVE. PROJECT LOCATION: SOU SPACE#354 MALLHCENTER 1240 SOUTHCENTER MALL TUKWILA, WA 98188 DIVISION 05 METALS A. METAL FRAMING: 1. LIGHT GAUGE METAL FRAMING: a. ALL STUD FRAMING MEMBERS, RUNNER TRACKS, BRIDGING AND NON -LOAD BEARING STUDS SHALL BE OF TYPE AND SIZE INDICATED ON DRAWINGS. b. PROVIDE ALL FASTENERS, SCREWS, BOLTS, CLIPS, ANCHORS, ANGLES, BRIDGES, BRACKETS, SLEEVES, ETC. AS REQUIRED. c. MATERIALS AND INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH MANUFACTURER'S RECOMMENDATIONS. B. METAL FABRICATIONS / BRAKE METAL 1. PROVIDE SHOPS DRAWINGS DETAILING FABRICATION AND ERECTION OF EACH METAL FABRICATION INDICATED, INCLUDING PLANS, ELEVATIONS, SECTIONS AND DETAILS OF METAL FABRICATIONS AND CONNECTIONS. SHOW ANCHORAGE AND ACCESSORY ITEMS. ELEVATIONS, ISSUED DRAWING LOG NO. DATE DESCRIPTION 12/27/17 ISSUED FOR LL APPROVAL REVIEWED FOR j !� Co��rlal_iA�CE �t'''�$�VI 4:% 01/04/18 ISSUED FOR PERMIT DIVISION 06 WOOD, PLASTICS & COMPOSITES DIVISION 08 OPENINGS JAN 19 PROJECT NO: 23706 A. CARPENTRY & BLOCKING: 1. BEFORE USING WOOD FRAMING OR BLOCKING OF ANY TYPE, CONFIRM CODE RESTRICTIONS. IF USE OF WOOD IS PERMITTED BY REQUIREMENTS, ADHERE TO THE FOLLOWING GUIDELINES: a. USE NEW LUMBER BEARING GRADE AND TRADEMARK OF ASSOCIATION UNDER WHICH IT WAS PRODUCED. b. LAYOUT, CUT, FIT AND ERECT FRAMING FOR ROUGH AND FINISHED WORK. INSTALL BLOCKING, NAILERS, FURRING AND OTHER ROUGH AND FINISHED MATERIALS AS REQUIRED. BRACE, PLUMB, AND LEVEL MEMBERS IN TRUE ALIGNMENT AND RIGIDLY SECURE IN PLACE WITH SUFFICIENT NAILS, SPIKES, SCREWS AND BOLTS AS NECESSARY. c. FURNISH AND INSTALL ROUGH AND FINISHED PLYWOOD, FURRING SUPPORTS, ETC. FURNISH AND INSTALL ALL ROUGH HARDWARE, ANCHORS, BOLTS, ETC. AS REQUIRED FOR CARPENTRY WORK. d. ALL EXISTING OR NEW WOOD SHALL BE FIRE RETARDANT AND MUST BE IDENTIFIED WITH A UL LABEL CERTIFYING THIS CLASSIFICATION. e. WORKMANSHIP AS PER THE ARCHITECTURAL WOODWORK INSTITUTE'S ARCHITECTURAL WOODWORK QUALITY STANDARDS. B. MILLWORK: 1. RECEIVE AND INSTALL ALL OWNER PROVIDED FINISHED MILLWORK, CABINETS, PANELING, DOORS AND FRAMES, ETC., AS SHOWN ON DRAWINGS OR AS DIRECTED. 2. CUT, FIT, AND INSTALL ALL MILLWORK AND SET PLUM AND TRUE IN ACCORDANCE WITH ASSEMBLY/INSTALLATION DRAWINGS PROVIDED. 3. BACK CUT FLLOCT TRIM Q PREVENTEMENTWARPING. DRILL WHERE NECESSARYCLOGO PREVENT LIEITTING. 4. CONFIRM BLOCKING REQUIREMENTS WITH VENDORS PRIOR TO CLOSING UP ALL ASSEMBLIES. A. DOORS AND HARDWARE: 1. FURNISH AND INSTALL ALL DOORS, FRAMES, HARDWARE AND RELATED PARTS MD MATERIALS AS INDICATED ON DRAWINGS AND RESPONSIBILITY SCHEDULE. 2. LABELED DOORS: PROVIDE U.L. LABEL DOORS AND FRAMES PER APPLICABLE ST/TF LOCAL BUILDING CODES, WHERE REQUIRED. 3. FABRICATE AND ERECT TRUE, PLUMB, AND SQUARE AS SPECIFIED AND DETAILED PER MANUFACTURER'S RECOMMENDATIONS. 4. SEE DOOR SCHEDULE FOR SPECIFIC INFORMATION AND HARDWARE. B. GLASS AND GLAZING: 1. TENANT G.C. TO CONFIRM EXISTING CONDITION OF STOREFRONT DOORS & GLAZING��t,�� WITH TENANT PROJECT MANAGER. TO BE CLEANED TO LIKE/NEW CONDITION FOR TENANT USE. I Ci4Y �f Tl` T1DIL�(�(L ,- .� �tirvi� " •?34 �/ STATE LIC. #: EXP. �' DAVID OF R:'h4 & �`�® ' c �` / 1 y �` A. UDkr1 if? o ,j DRAWING TITLE: ARCHITECTURAL SPECIFICATIONS AND AS 208-00-000-3408 DATE: 07/03/2019 DRAWING A003 DIVISION 09 FINISHES DIVISION 12 FURNISHINGS LANDLORD NOTES TENANT: verizori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moi 7' WATER AND DRAIN LINES SUPPLYING EQUIPMENT THAT IS TO BE REMOVED SHALL BE DISCONNECTS', PFMOVED AND CAPPED ABOVE CEILING OR BELOW FLOOR. IF CONTINUITY OF SYSTEM MUST BE M4N1AINED FOR USE BY ADJACENT TENANT SPACES, CONTRACTOR SHALL REROUTE, AS NECESSARY, TO BE BEHIND NEW CONSTRUCTION. 6. CONTRACTOR SHALL BE RESPOZ'BLE FOR REMOVING FROM STE, ALL RUBBLE AND DEBRIS CAUSED BY DEMOLITION AND DISPOSING OF li INA PROPER MANNER. PROVIDE HAUL ROUTE TO MALL MANAGEMENT FOR REMOVAL OF RUBBLE OR DEBRIS. PROTECT MALL FLOOR WITH MASONITE OR SIMILAR WHEN USING CARTS, DOLLIES OR OTHER TRANSPORTATION METHODS. DEBRIS REMOVAL MUST NOT BE VISIBLE IN THE MALL COMMON AREA DURING BUSINESS HOURS. 7. NOTIFY MALL MANAGEMENT OF ANY SPRINKLER REWORK TWO BUSINECS DAYS IN ADVANCE. 8. SPRINKLER DRAIN DOWN FEE MUST BE PAID IN ADVANCE DURING PRE-CONS-0ICITON MEETING. ENSURE SPACE IS COMPLETELY SEALED DURING DEMOLITION SUCH THAT DUST DOES NeZT TRAVEL THROUGH THE COMMON PLENUM TO ADJACENT TENANT SPACES OR MALL COMMON AREA. RESTORATIONWITH VENTS. 110. SPRINKLER ANDVENTS, TION COMPANY MUST BE N STANDBY DURING DEMOOR TO COVERING LITION. 11. PROTECT MALL FINISHES - PATCHBACK AS NECESSARY. CONTACT FACILITIES FOR MALL TILES. REFER TO CONSTRUCTION MANUAL FOR CEILING AND NEUTRAL PIER PAINT SPEC. 12. GC TO CONDUCT DEMOLITION WALK-THROUGH WITH TC AND MALL FACILITIES PRIOR TO ANY NEW WORK. COORDINATE CEILING ACCESS PANEL LOCATIONS WITH MALL FACILITIES PRIOR TO INSTALLING NEW CEILING. 13. NOT WITHSTANDING ANYTHING TO THE CONTRARY WITHIN THESE PLANS AND OTHERWISE SET FORTH IN THE EXECUTED LEASE, THE TENANT ACCEPTS THE LEASE PREMISES AND ALL HVAC, ELECTRICAL, PLUA. 14. ALLBING, AND FIRE PROTECTION REUSEDEQUIPMENT/MATERIALS MUSTTSBEAS IS" AND RETURNED TOELKEE SNO LANDLORD WORK. NEW CONDITION. APPROVAL BY LANDLORD REQUIRED. 1290-B EAST ARLINGTON BLVD. GREENVILLE, NC 27858 3. EXTERIOR APPLICATIONS: PROVIDE A GLASS MAT GYPSUM SUBSTRATE FOR USE AS SHEATHING. 4. WET LOCATIONS: PROVIDE A WATER-RESISTANT GYPSUM BACKING BOARD OR GLASS MAT DIVISION 13 SPECIAL CONSTRUCTION PROJECT PLANNER: WJCA INC. 763 SUSQUEHANNA AVE. FRANKLIN LAKES, NJ 07417 TEL: 201-848-9060 FAX: 201-848-9881 WATER- RESISTANT GYPSUM BACKING BOARD. 5. FASTENERS: DRYWALL SCREWS OF PROPER SIZE AND TYPE INSTALLED PER GA -216.A. 6. ACCESSORIES AND TRIM: U.S. GYPSUM BOARD OR GOLD BOND SYSTEM OF COMPONENTS AND PERFORATED TAPE. ALL METAL TRIM SHALL BE PERFORATED FLANGE TYPE FOR COMPOUND FINISH. WHERE A VAPOR RETARDER IS REQUIRED PROVIDE A FOIL BACKED GYPSUM BOARD, VAPOR RETARDER FACED MINERAL OR GLASS FIBER INSULATION NO WORK ANTICIPATED UNDER THIS SECTION, CONFIRM WITH THE PROJECT REPRESENTATIVE. BLANKETS. 7. INSTALL ALL MATERIALS PER MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS. 8. PROVIDE AT A MINIMUM A LEVEL 4 FINISH PRIOR TO THE APPLICATION OF THE FINAL DIVISION 14 CONVEYING EQUIPMENT FINISHES. REFER TO THE GYPSUM ASSOCIATION GUIDELINES FOR A DESCRIPTION OF THE DESIRED LEVEL. A. NO WORK ANTICIPATED UNDER THIS SECTION, CONFIRM WITH THE PROJECT REPRESENTATIVE. B. PAINTING AND FINISHING: 2. REFER TO RESPONSIBILITY SCHEDULE AND FINISH SCHEDULE. 3. GENERAL: USE THE ANT ANATED MTERIALS PECIFIED. THIOROU D RELBEFOREAAPPL F- DIVISIONS 1520 NOT USED -OPEN FOR FUTURE EXPANSION ARCHITECT: DAVID A. UDKOW 11881 NORTI--L 1.1.331 1, WAY SCOT AI X8$259 CITY OF TU KW I LA ' JAN 2018 PERMIT CENTER ba. . DRY ALONLY COATS COA S INGSSUCCEEDING COATS. FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR RE -COAT TIME. c. COVER ALL SURFACES THOROUGHLY. IF THE NUMBER OF COATS SPECIFIED DOES c. NOT ACCOMPLISH THE INTENT, THEN APPLY ADDITIONAL COATS OF SPECIFIED MATERIAL TO GIVE SATISFACTORY COVERAGE. - d. PREPARE BY CLEANING ALL SURFACES FREE OF LOOSE DIRT AND DUST. e. PREPARE ALL METAL SURFACES IN STRICT ACCORDANCE WITH MANUFACTURERS WRITTEN SPECIFICATIONS. DIVISION 21 FIRE SUPPRESSION f. BEFORE GHTIN STARTINGUFINISH WORK, REMOVE PROVIDE, ACCESSORIES, IONTES, LIGHTING FIXTURES AND SIMILAR ITEMS, OR PROVIDE AMPLE PROTECTION FOR SUCH ITEMS. g. MAKE FINISH WORK UNIFORM OR APPROVED FINISH, SMOOTH, FREE OF RUNS, SAGS, AND DEFECTIVE BRUSHING AND CLOGGING. MAKE EDGES OF PAINT ADJOINING OTHER MATERIALS OR COLORS SHARP AND CLEAN WITHOUT NO WORK ANTICIPATED UNDER THIS SECTION, CONFIRM WITH THE PROJECT REPRESENTATIVE. PROJECT LOCATION: SOUTHCENTER MALL SPACE#354 1240 SOUTHCENTER MALL TUKWILA, WA 98188 OVERLAPPING. h. EXTRA MATERIALS TO BE MAINTAINED AT THE SITE: 1 UNOPENED GALLON OF EACH PAINT. DIVISION 22 PLUMBING 3. INTERIOR: a. PAINTED DRYWALL TO RECEIVE ONE COAT LATEX PRIMER AND TWO COATS OF SPECIFIED PAINT. TINT PRIMER TO APPROXIMATE SHADE OF THE FINAL COAT TO PRODUCE AN EVEN RESULT IN THE FINISH COAT. b. SEAL ALL DRYWALL SURFACES BEHIND MIRRORS AND BUILT-IN COMPONENTS.p PUTTY ALL NAIL HOLES, COUNTER SUNK SCREWS, BOLTS, CRACKS, ETC. BEFORE WORK ANTICIPATED UNDER THIS SECTION, CONFIRM WITH THE PROJECT REVIEWED FOR CODE COMPLIANCE 1rt'� A VI [L4 iOV D { JAN ti 03 �O �$ JH • City of Tukwila BUIWt, "" e ISSUED DRAWING LOG c. APPLYING FINISH.DIVISION d. SAND ALL WOOD SURFACES SMOOTH AND EVEN BEFORE APPLYING FINISH. PAINT ALL RADIATION COVERINGS, CONVECTORS, REGISTERS, LOUVERS, GRILLES, 23 HVAC NO. DATE DESCRIPTION 12/27/17 ISSUED FOR LL APPROVAL e. EXPOSED PIPING, ACCESS DOORS, VENTS, FIRE EXTINGUISHER CABINETS,A. EQUIPMENT MOUNTING BOARDS, ETC. UNLESS FACTORY FINISHED. C. TRANSITION STRIPS: 1. REFE2. NO WORK ANTICIPATED UNDER THIS SECTION, CONFIRM WITH THE PROJECT REPRESENTATIVE. 01/04/18 ISSUED FOR PERMIT NS ALLTTTRANSITIONSTHEILS BETWEENFOREQUIRED DISSIMILARAFLOORNMATERIALS. 3. NO TRANSITION SHALL EXCEED REQUIREMENTS SET FORTH IN ADA, ANSI 117.1 -CURRENT ADDITION, OR ANY OTHER AUTHORITY HAVING JURISDICTION. DIVISION 25 INTEGRATED AUTOMATION B"-' PROJECT NO: L 6 23706 A. NO WORK ANTICIPATED UNDER THIS SECTION, CONFIRM WITH THE PROJECT DIVISION 10 SPECIALTIES REPRESENTATIVE. 3408 0 IP sTATEO• LIC. #: 208-00-000-3408 EXP. DATE: h i1 , t:END ^RCHrIECT RE :INT , 5 l��Q A. UO NGTON W 07/03/2019 DRAWING TITLE: ARCHITECTURAL SPECIFICATIONS & LANDLORD NOTES A. TOILETRROOM ARCHITECTURAL 1. REFER TO THE ARCHITECTURAL DRAWINGS FOR EXISTING TOILET ROOM LOCATION. DIVISION 26 ELECTRICAL 2. INSTALL IN -WALL BLOCKING AS REQUIRED TO PROVIDE ADEQUATE SUPPORT. 3. INSTALL ACCESSORIES AS REQUIRED OVER FINISHED WALL SURFACE. A. REFER TO REFLECTED CEILING AND ELECTRICAL PLAN FOR LOCATION OF NEW J -BOX FOR STOREFRONT SIGNAGE, LOCATION NEW OUTLETS, AND LOCATION NEW DATA. ALL OTHER LIGHTING IS EXISTING TO REMAIN. DIVISION 11 EQUIPMENT A. POINT OF SALE (P.0.5.) EQUIPMENT 1. REFER TO ELECTRICAL PLANS. 2. COORDINATE INSTALLATION WITH TENANTS VENDOR. DRAWING NO: A004 POST DEMOLITION CONFIRMATION NOTES 1. UPON INITIAL COMPLETION OF DEMOLITION, CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS WITH LOD (I.E., OVERALL DIMENSIONS, COLUMN LOCATIONS , LOCATION OF SERVICES, STRUCTURE, CLEARANCES, CONDITION OF CONCRETE SLAB, ETC.) AND REPORT ANY DISCREPANCIES, OMISSIONS, OR OBSTRUCTIONS THAT WILL AFFECT THE LAYOUT OR DESIGN OF THE SPACE WITHIN 24 HOURS TO INFORM THE LANDLORD. 2. CONFIRM THERE ARE NO PROJECTIONS BEYOND THE LEASE LINE TO LANDLORD. 3. FIELD DIMENSION BOX CODED NOTES 2. LEASE LINE - VERIFY LOCATION WITH LANDLORD REPRESENTATIVE. EXISTING DEMISING PARTITIONS AND STRUCTURAL ELEMENTS TO REMAIN: PROTECT DURING THE WORK. PROTECT AND MAINTAIN EXISTING FIREPROOFING, FIRE SEPARATION AND FIRE RATING. O 0 LO 2 �-1 I 0-0" REVIEWED FOR CODE COMPLIANCE APPROVED JAN 3 0 2018 City of Tukwila BUILDING DJ J TENANT: verizon 1290-B EAST ARLINGTON BLVD. GREENVILLE, NC 27858 PROJECT PLANNER: WJCA INC. 763 SUSQUEHANNA AVE. FRANKLIN LAKES, NJ 07417 TEL: 201-848-9060 FAX: 201-848-9881 ARCHITECT: DAVID A. UDKOW 11881 NORTH 113TH WAY SCREligteliNtE.a 85259 CITY OF TUKWILA JAN112018 PERMIT CENTER PROJECT LOCATION: SOUTHCENTER MALL SPACE#354 1240 SOUTHCENTER MALL TUKWILA, WA 98188 ISSUED DRAWING LOG NO. DATE 12/27/17 01/04/18 DESCRIPTION ISSUED FOR LL APPROVAL ISSUED FOR PERMIT PROJECT NO: 23706 LEASE CONFIRMATION PJAN SCALE: 1/8" = 3408 REGISTERED RCHi iT Ova DAVID A. UDKO. STATE OF WASHINGTON LIC. #: 208-00-000-3408 EXP. DATE: 07/03/2019 DRAWING TITLE: LEASE CONFIRMATION PLAN DRAWING NO: A005 DEMOLITION NOTES CODED NOTES TENANT: 1. REMOVE EXISTING PARTITION, PREPARE FOR NEW FINISHES. VeriZOfl 1. COORDINATE ALL PHASES OF DEMOLITION FOR PROJECT, VISIT THE SITE PRIOR TO BID SUBMISSION AND VERIFY ALL EXISTING CONDITIONS (EG- OVERALL DIMENSIONS, CONDITION OF CONCRETE SLAB, LOCATION OF SERVICES, STRUCTURE, CLEARANCES, ETC.) AGAINST THE PROPOSED WORK. REPORT ANY DISCREPANCIES, OMISSIONS OR OBSTRUCTIONS TO TENANT REPRESENTATIVE THAT WILL AFFECT THE LAYOUT OR DESIGN IMMEDIATELY. NO ALLOWANCES WILL BE MADE FOR FAILURE TO DO 50. 2. REFER TO SPECIFICATIONS AND RESPONSIBILITY SCHEDULE FOR GENERAL CONDITIONS AND ADDITIONAL INFORMATION. 3. UPON COMPLETION OF DEMOLITION, ALL CONDITIONS AND DIMENSIONS ARE TO BE VERIFIED FOR VARIANCES AGAINST THE PROPOSED WORK. REPORT ANY DISCREPANCIES IMMEDIATELY TO TENANT REPRESENTATIVE. 4. PREVENT MOVEMENT OR SETTLEMENT OF EXISTING STRUCTURE(5). PROVIDE AND PLACE BRACING OR SHORING AND BE RESPONSIBLE FOR SAFETY AND SUPPORT OF STRUCTURE. ASSUME LIABILITY FOR SUCH MOVEMENT, SETTLEMENT, DAMAGE OR INJURY. 5. CEASE OPERATIONS AND NOTIFY THE LANDLORD AND CM IMMEDIATELY IF SAFETY OF STRUCTURE APPEARS TO BE ENDANGERED. TAKE ALL NECESSARY PRECAUTIONS TO PROPERLY SUPPORT THE STRUCTURE. DO NOT RESUME OPERATIONS UNTIL SAFETY IS RESTORED. G. ARRANGE AND PAY FOR DISCONNECTING, REMOVING AND CAPPING UTILITY SERVICES WITHIN AREAS OF DEMOLITION, DISCONNECT AND STUB -OFF. NOTIFY AFFECTED UTILITY COMPANY AND BUILDING MANAGER IN ADVANCE AND OBTAIN APPROVAL BEFORE STARTING THIS WORK. 7. PLACE MARKERS TO INDICATE LOCATIONS OF DISCONNECTED SERVICES. IDENTIFY SERVICE LINES AND CAPPING LOCATIONS ON PROJECT RECORD DOCUMENTS. 8. BURNING OF MATERIALS ON SITE IS NOT PERMITTED. 9. NO WORK I5 TO BE PERFORMED OUTSIDE THE LEASE LINE AS DEFINED BY THE LANDLORD.} I O. REPAIR ALL DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED AT NO COST TO THE OWNER. I I . PROVIDE TEMPORARY SERVICES AS NECESSARY FOR CONTINUOUS OPERATION FOR ALL LIFE/SAFETY DEVICES. MAINTAINCE/RELCOATE ANY FIRE PROTECTION SIGNALS OR EQUIPMENT AS REQ'D PROTECT FOR DURATION OF THE WORK.NEW 12. REMOVE DEMOLISHED MATERIALS, TOOLS AND REQUIREMENT FROM SITE UPON COMPLETION OF WORK. LEAVE SITE IN A CONDITION ACCEPTABLE TO THE CONSTRUCTION MANAGER. 13. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERITY THE EXTENT OF DEMOLITION WITH THE TENANT REPRESENTATIVE AND THE LANDLORD AND BRING ANY DISCREPANCIES TO BOTH PARTIES ATTENTION PRIOR TO FINALIZING THE BID AND COMMENCEMENT OF WORK. 14. A FIRE EXTINGUISHER MUST BE KEPT ON THE PREMISES AT ALL TIMES. 15. SYSTEMS AND COMPONENTS - ANY DAMAGE TO THESE ITEMS SHALL BE REPAIRED AT THE CONTRACTOR'S EXPENSE. I G. CONFORM WITH ALL LANDLORD'S BUILDING REGULATIONS AND PROCEDURES. 17. COORDINATE WITH LANDLORD FOR THE PROTECTION AND/OR STORAGE OF ANY ITEMS TO BE SALVAGED. 18. PROTECT ALL DEMISING PARTITIONS, STRUCTURAL ELEMENTS, AND EXISTING INTERIOR PARTITIONS TO REMAIN DURING THE WORK. PROTECT AND MAINTAIN EXISTING FIREPROOFING, FIRE SEPARATION, AND FIRE RATING. - __ - 6 2. EXISTING SLAB TO REMAIN: PROVIDE A SMOOTH LEVEL SURFACE THROUGHOUT ENTIRE PREPARE 1290-B EAST ARLINGTON BLVD. GREENVILLE, NC 27858 h 3. 4. LEASE AREA - SURFACE FOR NEW FINISHES - REFER TO FINIHS PLAN FOR SCOPE OF NEW WORK. REMOVE ALL FLOOR FINISHES. CLEAN AND PREPARE FLOOR FOR RECEIPT OF NEWii FINISHES. TEMPORARY BARRICADE INSTALLED BY MALL VENDOR AT TENANT'S PROJECT PLANNER: 1 763 SUSQUEHINC.ANNA AVE. FRANKLIN LAKES, NJ 07417 TEL: 201-848-9060 FAX: 201-848-9881 II I Ii I I 11 iiWJCA II 1I II 11 I II II II II ii II 11 11 II II 11 1 3 8 7 5. 6. 7. EXPENSE. TENANT GC TO COORDINATE W/MALL TEAM. ALL BARRICADE DOORS TO SWING IN. EXISTING GLAZING AND FRAMES TO REMAIN. RESTROOM TO BE ENTIRELY' REMODELED AND FIXTURES TO BE CLEANED AND READY FOR STORE OPENING. REMOVE EXISTING ARCHITECT: DAVID A. UDKOW 11881 NO Z.1AT/WA/AY SCOTT�M1-E>, Atit9 CITY OF T UK�'VILA JAN 1 1 2018 PERMIT CENTER 8. 9. CEILING SYSTEM ANL - LIGHTING. REMOVE EXISTING FLOOR/PERIMETER FIXTURES. EXISTING STOREFRONT TO BE PATCHED, REPAIRED, AND CLEANED BEFORE PROJECT LOCATION:- OCATION:8. SOUTHCENTER MALL SPACE#354 1240 SOUTHCENTER MALL TUKWILA, WA 98188 2 RE" COD. ,, J " " Cii�? BUIL �� IEC FO� COMPLIANCE iPFOVFii) 3 0 2018 of Tukwila INQ .f -t •-w.^ '� SIGN IS INSTALLED, ISSUED DRAWING LOG NO HOLES FROM NO. DATE DESCRIPTION PREVIOUS SIGN SHOULD BE VISIBLE. ENSURE 12/27/17 ISSUED FOR LL APPROVAL THAT ROLLING GRILLE IS 01/04/18 ISSUED FOR PERMIT IN GOOD WORKING ORDER AND ALL - HARDWARE IS UP TO CODE. 10. KEEP ADDRESS NUMBER IN SAME LOCATION ON GLAZING PANEL. PROJECT NO: 23706 ► 34D$ �l DAVID $TATE�F�1yAg}� R��� �rc�;,�1T� A. t1G:�{;? CT S �� DRAWING TITLE: DEMOLITION PLAN 10 4 LEGEND WALL TYPE NOTE: REFER TO SHEET , I EXISTING INTERIOR WALL TO REMAIN A004 FOR LANDLORD EXISTING TO BE REMOVED DEMOLITION NOTES LIC. #: 208-00-000-3408 EXP. DATE: 07/03/2019 DRAWING NO: ID 1 01 DEMOLITION PLAN SCALE: 1/8" = 1'-0" FIXTURE & RESPO\SI3ILTY SCHEDULE 15'-O" CODED NOTES TENANT: verizon FIXTURE LEGE \D SUPPLIED I\STALLED N/A. 1. 2. 3. 4. -" 5. 6. 8. Single Display Cube with snap frame for Redux Display. Thermostat provided by Tenant GC. T Shelf mounted on 48" x 48" plywood phone board by Tenant GC. IT Shelf to be above 6'-8". Restroom to be entirely remodeled and fixtures to be cleaned and readyfor store opening, P g° Ensure that waterproof membrane is intact - perform testing to confirm. Two Computers at employee printing station Television to be hung at 60" OC AFF. New interior privacy lock door. See Door Schedule. No Storefront work. Existing storefront to remain. Fixture Vendor 0 > 0 Tenant GC Landlord GC Fixture Vendor Tenant Vendor Tenant GC Landlord GC / V.I.F. I/2'/' 5,-4 I /2", 1290-B EAST ARLINGTON BLVD. GREENVILLE, NC 27858 4' 8° ,4'-7 • 4. r I' °u Shelving Ecbrical_ P'n:', , Phone safe • • a N — m m 3 5 4 - _ > C===1 Verizon Sign • • PROJECT PLANNER: WJCA INC. 763 SUSQUEHANNA AVE. FRANKLIN LAKES, NJ 07417 TEL:201-848-9060 FAX: 201-848-9881 u Cash Wrap • • - I iPad Display • • p 9 n I/2" / Dry Eras 0 � / __ [, I I iPhone Display • • •j Live Table ..mounted • • M III/ Display Cubes in - - 2 I O' 5" 4' 7"-i - - rd • • \\ Display Cube for REDUX P Y • • ONE TWO LED Slat Wall • • O 1 r — 5 - rn o I 1 Smart Zone • • Sit -Down Contract Desk • • ARCHITECT: DAVID A. UDKOW 11881 NORTH 113TH WAY SCOTTghFE ff259 CITY OF TUKWILA JAN 1 1 2018 PERMIT CENTER 1 II Standing Contract Desk • • O • — Snap Frame • • • O > 6 m ` Lighted Window Box • • Ln CiU _ o —_ 71- IT Shelf • • 6 N CP — a in — = - o c� in - - CD > PROJECT LOCATION: SOUTHCENTER MALL SPACE#354 1240 SOUTHCENTER MALL TUKWILA, WA 98188 UU •d' DOOR SCHEDULE O NEW 3'-0" X 6'-8" SOLID CORE INTERIOR DOOR WITH CLASSROOM LEVER LOCK HARDWARE BY LANDLORD GC. DOOR HARDWARE® NEW 3'-0" X 6'-8" SOLID CORE INTERIOR DOOR WITH PRIVACY LEVER LOCK HARDWARE BY LANDLORD GC. DOOR HARDWARE© —4 LANDLORD NOTE O , m —N •(___6-4"6' ih 8" J - — 1 1. Pedestal security systems are not allowed - install underground or semi ISSUED DRAWING LOG DOOR HARDWARE OA SPECIFICATIONS • DOOR HANDLE: DESIGN HOUSE C -SERIES CLASSROOM LEVER 2W, MODEL #701854, SATIN CHROME FINISH • KICK PLATE: SATIN ALUMINUM KICK PLATE 6" X 34", MODEL #J4702 • DOORSTOP: SATIN CHROME COMMERCIAL GRADE KICK DOWN DOORSTOP, 1.25" X 1.12" X 5.5', MODEL #15258 NO. DATE DESCRIPTION 12/27/17 ISSUED FOR LL APPROVAL C / - - ��� _ FOR corealed mounted Q °,:' wall units. 4 C f+ �EVIEVVCD 01/04/18 ISSUED FOR PERMIT / .A CODE CQVPi.IANC " J � 'i;:13 t APPROV DOOR HARDWARE © SPECIFICATIONS C 8'-4" o 6'-8 7 - i . ppPROJECT • K� JAN 30 2(110 • DOOR HANDLE: DESIGN HOUSE C -SERIES PRIVACY LEVER 2W, MODEL #701854, SATIN CHROME FINISH • KICK PLATE: SATIN ALUMINUM KICK PLATE 6" X 34", MODEL #J4702 • DOORSTOP: SATIN CHROME COMMERCIAL GRADE KICK DOWN DOORSTOP, 1.25" X 1.12" X 5.5", MODEL #15258 NO: 23706 m cV\ City of Tula BUILDING DIMS L "•'._ 4�8 _-�. F" ;��� RL::::::::: DRAWING TITLE: CONSTRUCTION / FIXTURE PLAN IT SHELF SPECIFICATIONS C Q ACV �` 8 al fCH!TECTj� tro I S %v DAVI�A STATE OF YVASj-�, r '�L,`•� EXP DATE: 07/03/2019 • BRACKETS : (6 PER STORE) - RUBBERMAID FASTTRACK WHITE BRACKET, ITEM #246465, MODEL #1817066, COLOR: WHITE, 2" X 0.5" X 12° • UPRIGHTS: (3 PER STORE) - RUBBERMAID FASTTRACK WHITE UPRIGHT, ITEM #62680, MODEL #FG3Q7400WHT, COLOR: WHITE,V 4: (15" X PER 0.875"TX 1" • SHELVING: (1 STORE, CUT IN HALF) - RUBBERMAID LINEN 6 FT X 12" WHITE WIRE SHELF, ITEM #246408, MODEL #61296, COLOR: WHITE LIGHTED WINDOW eox �m \ / 15'-Q" / 16'-0" / / V.I.F. LEGEND WALL TYPE DRAWING NO: Al 01 1 EXISTING WALLS TO REMAIN CONSTRUCTION/FIXTURE PLAN SCALE: 1/8" = 1'-0" GENERAL NOTES NEW 2' x 2' ACT DROP CEILING WITH NEW 2' x 2' LED RECESSED LITHONIA LIGHT FIXTURES BY TENANT GC. • TENANT GC TO CONFIRM THAT FIRE SPRINKLER SYSTEM IS IN WORKING CONDITION AND CODE COMPLIANT. • TENANT TO CONFIRM THAT ALL EMERGENCY LIGHTED SIGNS ARE WORKING AND CODE COMPLIANT. • COORDINATE WITH TENANT, NEW GWB CEILING TO BE PAINTED WHITE TO MATCH 2'X2' CEILING. CODED NOTES 2. Duplex Outlet in Ceiling. Existing sign circuit to J—Box at sign location to remain. LANDLORD NOTES 1. All sprinkler heads in sales area must be recessed and the covers painted to match the surrounding area. 2. No freestanding cameras will be allowed in the sales area — must be recessed into wall, etc. 3. All emergency and exit lighting in the front of house must be edge lit and have recessed base — no surface mounted. 4. cut sheets of all lighting fixtures in front of house must be submitted to landlord for approval. 5. If used any people counter systems must be concealed from view at storefront. N NEW ACT 1 CLG © 10'-0" AFF NEW ACT 1 CLG © 10'-0" AFF NEW GWB CLG • 10'-0" AFF REVIEWED FOR CODE COMPLIANCE • APPEOV!.:1 JAN 3 0 2018 City of Tukwila BUIL REFLECTED CEILING PLAN SCALE: 1/8" = 1'-0" TENANT: verizon 1290-B EAST ARLINGTON BLVD. GREENVILLE, NC 27858 PROJECT PLANNER: gii WJCA INC. 763 SUSQUEHANNA AVE. FRANKLIN LAKES, NJ 07417 TEL: 201-848-9060 FAX: 201-848-9881 ARCHITECT: DAVID A. UDKOW 11881 NORTH 113TH WAY SCQ1BO/Ef35259 CITY OF TUKWILA JAN 1 1 2018 PERMIT CENTER PROJECT LOCATION: SOUTHCENTER MALL SPACE#354 1240 SOUTHCENTER MALL TUKWILA, WA 98188 ISSUED DRAWING LOG NO. DATE DESCRIPTION 12/27/17 ISSUED FOR LL APPROVAL 01/04/18 ISSUED FOR PERMIT PROJECT NO: 23706 3408 Ri GISTE RCD /Rain- CT ( 2� 1. DAVID A. UDKO STATE OF WASHINGTON LIC. #: 208-00-000-3408 EXP. DATE: 07/03/2019 DRAWING TITLE: REFLECTED CEILING PLAN DRAWING NO: A1 02 FINISH SCHEDULE 1/8" WIDE SCHLUTER—SCHIENE TENANT: verizon FLOOR COVERING: FC—1 Shaw Industries, Inc. — Style # 10226, Moving On Up, Color # 00507, Bibbidy—Bobbidi—Boo (Provided by Victra) CARPET AMOUNT = 87 SQ. YDS. ALUMINUM TRANSITION STRIP FC -3 1290-B EAST ARLINGTON BLVD. GREENVILLE, NC 27858 FC -2 — Vinyl Composition Tile, Armstrong — #51904 Sterling by Tenant GC. FC -3 DALTILE — Porcelain floor tile, Color #ASHGREY P405. size 12"X12" tile, cutPr-2 equal / equal on both sides. WALL FINISH: —__—__—__—__—_____—___ PT -2 PROJECT PLANNER: MI WJCA INC. 763 SUSQUEHANNA AVE. FRANKLIN LAKES, NJ 07417 TEL:201-848-9060 FAX: 201-848-988181 WB1 FC -2 ACT -1 WB -1 Fc -2 1 ACT -1 u o' o p L, o n N PT -1 — Sherwin Williams Interior Paint—Web Gray, LRV 17% SW7075 (Walls—Eggshell, Doors & Frames—Semigloss) PT -2 — Sherwin Williams, SW #6196, "Frosty White" (Walls—Eggshell, Doors & Frames—Semigloss) WB -1 — Vinyl Wall Base, Armstrong, #R4060 Jet Black by Tenant GC. WB -2 — Wood Wall Base, coordinate with Tenant. Wood Wall Base painted Jet Black by Tenant GC. CEILING FINISH: z z ALIGN 2PT-1 WB -z MALL FLOORING ARCHITECT: DAVID A. UDKOW 11881 NORTH 113TH WAY ;CQJF-S,DA-lAZ85259 CITY OF TUKWILA JAN 1 1 2018 PERMIT CENTER CONCRETE SLAB O2 TRANSITION DETAIL SCALE: 6" = 1 -O' 1/8" WIDE SCHLUTER—SCHIENE ALUMINUM TRANSITION STRIP ACT -1 — New suspended USG Radar Basic Acoustical Panels with 2' x 2' flat white 050 square grid by Tenant GC. (Product # SC228) ACT -2 — New GWB ceiling to be painted white to match new 2'x2' ACT. Ceiling height: 10'-0" FC 1 PT -2 WB -2 PROJECT LOCATION: SOUTHCENTER MALL SPACE#354 1240 SOUTHCENTER MALL TUKWILA, WA 98188 FC -1 Act -1 I •1 CODED NOTES \VAVNNAVAVIVl l ANN) o ° o o °p n o ° 1. 2. 3. Vinyl transition strip to match vinyl wall base supplied by Victra and installed by Tenant—GC. Door and jamb to be painted Sherwin Williams Web Interior Paint — Web Gray, LRV 17% SW7075. Ensure there is a smooth transition between the mall floor and sales floor. All finishes must be flush with one another and no tripping hazards. Lips more than 1/16" and slopes of more than 1/2" per foot are not accepted. ISSUED DRAWING LOG NO. DATE DESCRIPTION ALIGN 12/27/17 ISSUED FOR LL APPROVAL FC -3 01/04/18 ISSUED FOR PERMIT CONCRETE SLAB PT -2 A103 WB -2 Fc-' ACT -1 PROJECT NO: 23706 0 TRANSITION DETAIL SCALE:u061("0= 1'—O" ' PT -2 Q wB-2 f REVIEWED F0� CODE COMPLIANCE APCVE:D JAN 3 0 2018 City of Tukwila -. 1 _ 3408,c&I] 13q�1t�q& STATE �� WASHJN(� -0 , fi DRAWING TITLE: FINISH PLAN, SCHEDULE, DETAILS — ACT -2 .� — 2 3 A103 DRAWING NO: Al 0 3 Bl qi-S-) , FINISH PLAN SCALE: 1/8" = 1 —0' LIC. #: 208-00-000-3408 EXP. DATE: 07/03/2019 (N CAD OPER. - DATE - RLM -17489-E101 ELECTRICAL POWER PLAN CODED NOTES PROVIDE AND INSTALL FLOOR BOX AND CAT5 DATA DEVICE WITHIN FLOOR AT DISPLAY. RUN 1' EMPTY CONDUIT WIN PULL WIRE FROM 1 FLOOR BOX BELOW SLAB TO NEAREST FULL HEIGHT WALL, UP WALL TO ABOVE ACCESSIBLE CEILING, THEN TO TELEPHONE BOARD. TRENCH AND PATCH FLOOR AS REQUIRED. COORDINATE ALL FLOOR CUTTING WITH LANDLORD PRIOR TO STARTING WORK. 2. O PROVIDE AND INSTALL 120V. 20A DUPLEX RECEPTACLE. PROVIDE AND INSTALL DATA DEVICE(S) IN QUANTITIES SHOWN. RUN 1' EMPTY CONDUIT WITH PULL WIRE FROM DATA DEVICE(S) TO PHONE BOARD. COORDINATE EXACT MOUNTING HEIGHT AND LOCATION WITH TENANT REPRESENTATIVE PRIOR TO STARTING WORK. 3O PROVIDE AND INSTALL 120V. 20A DUPLEX RECEPTACLE WITHIN CEILING AT STOREFRONT WINDOWS COORDINATE EXACT MOUNTING LOCATION WITH OWNER PRIOR TO ROUGH -IN. O4 G.C. 1O WRENCH FLOOR FROM NEAREST FULL HEIGHT WALL TO RECEPTACLE LOCATIONS SHOWN ON PLAN. EC TO PROVIDE AND INSTALL CONDUIT FROM RECEPTACLES, THROUGH TRENCH 1O ELBOW TO EXTEND CONDUIT TO 6' ABOVE FINISHED CEIUNG. EC TO PROVIDE AND INSTALL WIRE IN CONDUIT FROM ELECTRICAL DEVICES TO CIRCUITS SHOWN ON PLAN. G.C. TO BACKFILL TRENCH WHEN EC. HAS COMPLETED WORK. Q5 PROVIDE AND INSTALL FLOOR BOX WITH 120V. 20A DUPLEX RECEPTACLE. COORDINATE EXACT MOUNTING LOCATION WITH OWNER PRIOR TO ROUGH -IN. WIRING TO RECEPTACLE SHALL BE FLAT WIRE TYPE © EXISTING 120/208V. 3/, 4W, 100A MCB ELECTRICAL PANEL 'A' TO REMAIN. O7 EXIS11NG TELEPHONE BOARD AND TELEPHONE SERVICE EQUIPMENT. • PROVIDE AND INSTALL 120V. 20A DUPLEX RECEPTACLE AT 20' A.F.F. VERIFY EXACT MOUNTING LOCATION WITH TENANT REPRESENTATIVE PRIOR TO ROUGH -IN. OSI PROVIDE AND INSTALL JUNCTION BOX AND 120V. 20A TOGGLE SWITCH DISCONNECT IN ACCESSIBLE LOCATION ON INTERIOR SIDE OF STOREFRONT FOR CONNECTION TO STOREFRONT SIGN. COORDINATE EXACT MOUNTING LOCATION AND REQUIREMENTS WI1H SIGN PACKAGE PROVIDER PRIOR TO STARTING WORK. CIRCUIT THROUGH TIME CLOCK 'TCR'. ELECTRICAL LIGHTING PLAN CODED NOTES O CIRCUIT THROUGH TIME CLOCK 'TCW'. 2Q PROVIDE AND INSTALL 24 HOUR, 7 DAY PROGRAMMABLE ASTRONOMICAL TIME CLOCK '101'. CONTACTOR, AND ENCLOSURE FOR CONTROL OF INTERIOR BUILDING UGHTING IF NOT EXISTING. MOUNT TIME CLOCK WITHIN NON -SALES AREA. PROVIDE AND INSTALL 2 HOUR OVERRIDE SWITCH FOR OVERRIDE CONTROL MOUNT OVERRIDE SWITCH NEXT TO SALES UGHT SWITCH BANK. PROVIDE AND INSTALL 2 -HOUR OVERRIDE SWITCH FOR OVERRIDE CONTROL OF TIME CLOCK 'TCW'. MOUNT SWITCH NEXT TO SALES AREA SWITCH BANK. C> PROVIDE AND INSTALL 24 HOUR, 7 DAY PROGRAMMABLE ASTRONOMICAL TIME CLOCK '102 IF NOT EXISTING FOR CONTROL OF EXTERIOR BUILDING SIGN. MOUNT TIME CLOCK IN NON -SALES AREA. PROVIDE AND INSTALL WALL MOUNTED OCCUPANCY SENSOR. CONNECT ALL EXIT, EMERGENCY, AND NIGHT UGHTING TO LOCAL CIRCUIT AHEAD OF SWITCHES SALES AREA SWITCH BANK LOCATION. COORDINATE EXACT MOUNTING HEIGHT AND LOCATION WIN OWNER PRIOR TO ROUGH -IN. PANELBOARD PANEL NEMA PANEL WIRING A� SCHEDULE VOLTAGE MAINS MOUNTING (3-PHASE) 120/208 PHASE MAINS OPTIONS 3 WIRE RATING 4 AIC RATING EXISTING TYPE EXISTING 2.025 100A MCB 225A LTHONIA 1.0 < 10KW TYPE ENCLOSURE 1 SURFACE --- NOTE 0.5 REMAINING KW 3.960 HVAC 11.526 1.0 OR. NA LOAD DESCRIPTION BRKR. SIZE • NOTE N.E.C. KVA OA N.E.C. KVA AB NE.C. KVA 41C PHASE NEC. KVA ilA N.EC KVA OD N.EC. KVA 0C NOTE BRKR SE • LOAD DESMIP110N OR N0. 1 REC - TEEPHONE/LT. N.E.C. DEMAND KVA x 1000 1.0 0.540 19.311 x 1000 AMPS RE -USE EXISTING 100 AMP SERVICE A 1.200 TC LTS - STOREFRONT 9G1 2 3 REC - NON -SALES 0.360 B 0.420 L1S - SNES/N01-SNFS/IiSN0U1 4 5 REC - RESIR0G1 0.180 C - SPARE 6 7 EXISTING WATER HEATER 1.800 A - SPARE 8 9 REC - SALES 0.900 B - SPARE 10 11 REC - SALES 0.540 C - SPARE 12 13 REC - SALES 0.720 A - 40/2 }SPARE 14 15 REC - SALES 0.540 B - I 16 17 REC - STOREFRONT 0.180 C - 40/2 18 19 SPARE - A - /SPARE I 20 21 SPARE - B - SPARE 22 23 SPARE - C - SPARE 24 25t 3.842 A - t 26 27 BASTING HVAC 140/3 HACR 3.842 B - 100/3 /MAIN CIRCUIT BREAKER 28 29 3.842 C - 1 30 WES 1.1.0 L CROAT BREAKERS TO EE 20 -AMP, 2. ALL PHASES S TO BE BALANCED TO -POLE UNLESS AMUSE NOTED. R 108 USING ACTUAL LOAD TOTALS PANEL LOAD SUMMARY - HANDLE LOCK -011 COACE ST - SHUT TRP TYPE g0 - 91018 FAULT CR JT NIBRIPIR INCR - KEANq A/C L RUMBA= SF - SI.B-FEED BREAM E# - NN SON TUBI K 0001 % N.E.C. CONNECTED TOTALS NA 8.102 KVA 08 6.062 KVA TIC 4.742 KVA TOTAL 18.906 KVA 208 LOAD SUMMARY xSTE DESCRIPTION N.E.C. CONNECTED KW/KVA POWER FACTOR N.E.C. DEMAND FACTOR N.E.C. DEMAND KVA LIGHTING 1.620 ♦ 1.25 2.025 WAT 8 A LTHONIA 1.0 < 10KW 120 RECEPTACLES 3.960 1.0 0.5 REMAINING KW 3.960 HVAC 11.526 1.0 1.0 • 11.526 WATER HEATER 1.800 1.0 1.0 1.800 TOTAL 18.906 LITHONIA 19.311 • 125X OF THE LARGEST MOTOR OR COMPRESSOR IN SYSTEM. 1ELM2 LED APPUED ONLY ON ONE UNIT. A POWER FACTOR IS ALREADY INCLUDED IN UGHTING LOAD. N.E.C. DEMAND KVA x 1000 MINIMUM FEEDER AMPERAGE = SYSTEM VOLTAGE x 19.311 x 1000 AMPS RE -USE EXISTING 100 AMP SERVICE = 53.6 208 x 1.73 GENERAL NOTES EC. IS RESPONSIBLE TO SECURE AND PAY FOR ALL PERMITS, ADHERE TO ALL STATE, LOCAL AND NATIONAL ELECTRIC CODES, AND SCHEDULE INSPECTION TIMES AS TO NOT DELAY JOB PROGRESS. COORDINATE ALL WORK WITH OTHER TRADES TO ELIMINATE CONFLICTS ON NE JOB. 3. PERFORM ALL WORK IN A NEAT AND PROFESSIONAL MANNER, AND SUPPLY ALL NEW EQUIPMENT AND ACCESSORIES 4. SUBMIT SHOP DRAWINGS AND OPERATION MANUALS OF ALL EQUIPMENT AND ACCESSORIES FOR OWNER APPROVAL, PRIOR TO STARTING WORK. 5. ALL UNE VOLTAGE WIRING IS TO BE IN CONDUIT OR MC CABLE MINIMUM SIZE CONDUIT TO BE 1/2 FOR INDIVIDUAL UGHT FIXTURE CONNECTIONS, AND 3/4' FOR ALL OTHER LOCATIONS. FLEXIBLE CONDUIT TO BE MC CABLE (NO BX). 6. ALL ELETRICAL PANELS ARE TO BE BASED ON SQUARE b' OR EQUAL BY G.E. OR ITE SIEMENS WITH BOLT -CN TYPE CIRCUIT BREAKERS, 7. ALL PENETRATIONS OF WALL, ROOF AND CEILINGS TO BE SEALED AS REQUIRED WITH UL APPROVED FIRE SEALANT PER MANUFACTURERES DETAIL TO MAINTAIN FIRE RATING AS REQUIRED. CONTRACTOR TO HAVE UL APPROVED DETAIL ON SITE 8. CONDUITS AND/OR CABLES INSTALLED UNDER ROOF DECKING SHALL HAVE A MINIMUM OF 1 1/2' SPACE BETWEEN CONDUITS AND/OR CABLES AND ROOF DECKING PER NEC ARTICLE 300.4 (E). 9. PANELBOARDS, METER SOCKET ENCLOSURES ETC... THAT ARE LIKELY TO REQUIRE EXAMINATION, ADJUSTMENT, SERVICING, OR MAINTENANCE WHILE ENERGIZED SHALL BE FIELD MARKED TO WARN QUALIFIED PERSONS OF POTENTIAL ELECTRIC ARC FLASH HAZARDS PER NEC 110.16. 10. ALL WIRING IS TO BE COLOR -CODED AS FOLLOWS: 120/208 VOLT SYSTEM: 277/480 VOLT SYSTEM: NEUTRAL - WHITE NEUTRAL - GRAY PHASE A OR L1 - BLACK PHASE A OR L1 - BROWN PHASE B OR L2 - RED PHASE B OR L2 - ORANGE PHASE C OR 1.3 - BLUE PHASE C OR 1..3 - YELLOW GROUND - GREEN GROUND - GREEN WITH YELLOW TRACER 11. PROVIDE FLEXIBLE CONDUIT FOR ALL VIBRATING EQUIPMENT, NOT TO EXCEED 3 FT. IN LENGTH. 12. MINIMIZE EXPOSED CONDUIT BY CONCEALING IN WALLS AS MUCH AS. POSSIBLE. 13. BALANCE ALL PANELS WITHIN 108 OF EACH PHASE LEG. 14. PROVIDE LABELS AND TAGS FOR ALL PANELS AND SWITCHGEAR EQUIPMENT. PROVIDE TYPED DIRECTORY CF ALL CIRCUITS LABELED BY R001.1 NUMBER OR NAME. 15. CIRCUIT ALL EMERGENCY UGHT FIXTURES, EXIT SIGNS AND NIGHTUGHTS (NL) TO LOCAL CIRCUIT AHEAD OF ANY SWITCHING. 16. REFER TO MECHANICAL PLAN FOR LOCATION OF MECHANICAL EQUIPMENT. FIELD VERIFY EXACT LOCATIONS 17. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH NATIONAL ELECTRIC CODE AND ALL LOCAL CODES AND ORDINANCES NE CONTRACTOR SHALL INQUIRE INTO AND COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS AFTER CONTRACT IS ISSUED, NO ADDITIONAL COST DUE TO CODE ISSUES SHALL BE REIMBURSED BY THE OWNER TO NE CONTRACTOR. 18. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO INQUIRE WITH THE LOCAL CODE AUTHORITY ON ANY FIRE ALARM SYSTEM REQUIREMENTS IF THE FIRE ALARM SYSTEM IS NOT ADEQUATELY DESCRIBED ON THE DRAWINGS. 'THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO INFORM THE GENERAL CONTRACTOR AND INCLUDE THE COST AS A SEPARATE UNE ITEM IN THE BID. NO ADDITIONAL MONIES SHALL BE AWARDED WITHOUT A SEPARATE UNE ITEM FOR THE FIRE ALARM SYSTEM AT THE TIME OF THE BID. 19. ELECTRICAL CONTRACTOR SHALL VERIFY EXACT/ALL MOUNTING HEIGHTS, LOCATIONS AND COLOR (FINISH) OF ALL DEVICES AND EQUIPMENT WITH THE ARCHITECT AND/OR OWNERS REPRESENTATIVE PRIOR TO ROUGH -IN. 20. EC IS TO KEEP A CURRENT COPY OF NE AS -BUILT CONDITIONS DURING THE PROJECT. AT THE END OF NE PROJECT, THE EC SHALL TURN OVER TO NE OWNER 3 COPIES OF THE FINAL AS -BUILT DRAWINGS ELECTRICAL LEGEND 0' 2 2 s 0 120 YO -T. 20 APP. DUPLEX RECEPTACLE 120 VOLT. 711 ALP. DOUBLE METE% RECEPTACLE DATA OUTLET. PRONG( 3/4' C. ICH REL 611110 TO A00WW A0®E COUPE TELEPHONE OUTLET. iRONOE 3/4' C. OEM RLL IMMO TO A001E ACCEPSIELE COLIC. CATAL DROP 120 YOLT. 20 AW. LUMEN 08 MflEITCLIALAIE AWL TA 10111 OPER NORT ALL TPR 311021 AT 4r A r TO IEE= MIM0 YOUNT AL NFOEPTADR AT IVAFF TO MATCH IMMO MMus 11018 0114001(t • 1 0 ©©III MI 'Cm 'TcHMIIIIII 1 01112, g -uf111 ,111, O 4D „1■RY NIMOWN 1 1111E 11111MINIK11111 MIMI Ilan 111111. IMIUMEMMI 1111111MONII IIIIL pin IBM I, ®Val ,I■■MEMIll A RECEIVED .ITYOFTUKW PERMI TENANT: verizon 1290-B EAST ARLINGTON BLVD. GREENVILLE, NC 27858 PROJECT PLANNER: WJCA INC. 763 SUSQUEHANNA AVE. FRANKLIN LAKES, NJ 07417 TEL: 201-848-9060 FAX: 201-848-9881 ENGINEER: Dan R. Rhodes, PE 7402 East Broad Street Blacklick, Ohio 43004 Phone: 614.204.2479 MEP Building Consultant PROJECT LOCATION: SOUTHCENTER MALL SPACE#354 1240 SOUTHCENTER MALL TUKWILA, WA 98188 ISSUED DRAWING LOG NO. DATE DESCRIPTION 12/22/17 ISSUED FOR LL APPROVAL / PERMIT 1 /4/18 ISSUED FOR PERMIT POWER PLAN SCALE: 1/4" = 1'-0" LIGHTING PLAN SCALE: 1/4" = 1'-X7' LIGHT FIXTURE SCHEDULE 111.1 A MANFACTLIRE i "MP V_QTYPE . _:.:; . �A II, WAT 8 A LTHONIA 17.5W LED 120 2'X2' LED LAY -IN FIXTURE - `. • RI #2VR2-20L-LP940 INCLUDED 17.5 • • s:• •V EX UTHONIAf QM LED LED INCLUDED 120 - LED �IXR/Y E ERGENCY UG=t+iy r�k.dl..4,.KUP. -, EM LITHONIA LED INCLUDED 120 LED EMERGENCY UGHT FIXTURE WITH 90 MINUTE BATTERY 1ELM2 LED _ BACKUP. PROJECT NO: _r 89 ;,x. .•kw ELCtR#.AW1 AWING NO: E-1 01 CAD OPER. DATE - RLM -17489-E102 CD H 0 RECEIVED CITY OF TUKWILA JAN 1 1 2018 PERMIT CENTER TENANT: verizon 1290-B EAST ARLINGTON BLVD. GREENVILLE, NC 27858 PROJECT PLANNER: WJCA INC. 763 SUSQUEHANNA AVE. FRANKLIN LAKES, NJ 07417 TEL: 201-848-9060 FAX: 201-848-9881 ENGINEER: Dan R. Rhodes, PE 7402 East Broad Street Blacklick, Ohio 43004 Phone: 614.204.2479 MEP Building Consultant PROJECT LOCATION: SOUTHCENTER MALL SPACE#354 1240 SOUTHCENTER MALL TUKWILA, WA 98188 ISSUED DRAWING LOG NO. DATE DESCRIPTION 12/22/17 ISSUED FOR LL APPROVAL / PERMIT 1/4/18 ISSUED FOR PERMIT PROJECT NO: 0 `3' ,. • DRAWING NO: E-102 Interior Lighting Summary 2012 WasHeaton C.0;mmFo�a,D«m.»w6tlaIrg.I PoPz.R,over 3•a,•• LTG -SUM and a•RI Rama 2014 Interior Lighting Summary - Building Area Method LTG -INT -BLD oI=W.P.�»Enemy maw »• mean, Passe 201. Lighting, Motor, and Transformer Permit Documents Checklist LTG -CHK >o,,.-,.9224.�p,a.a«r,..<e<,,....," .0.1.992. 09.20.0021 n. ,4 Lighting, Motor, and Transformer Permit Documents Checklist LTG -CHK m,=.,. a.•a-a,r.a.<2m�.�a< .a Y• an2amwa•�.01.., n..an ,. n Pmaendera90 mum W Space 1.354 13/aanoz7An Pmwamm So ...Prlan»»•M94 lo.. v/1•=0.17 22»g»am a.uem•r w• a»m•a» loaf. 11/=4/01= Project lnfosaav^+auaaa�e.4 a""umn. nm m .wed nap a mal are»IP mer a 5. 1:ne/10x7 Dansriwmo oop•mn.n u.. Lighting Alterations, Renovations & Building Additions Loss POP O Mures ,•parva .4aauwu mon 03433 as•�w'•cml 0ari .. : »p4wm m. m pl MM ampdaananymy» sap UN Amb Was end a»ro-namoa " Maximum All. a d M- - complyea tem»W wm Ow Ovunfl s ana<.w..mrerca•an•s. Odle Popo,. NOP.. a Document brtidex er a»n9am amain d nI.»wmaaNa,..;>a,wnam,a,,,a replaced, e,.LrG»,rsP.�En,m, FDane or .aag oapmmn use n.®� Tne '^.m•", a°.°• pipe 900220/»m°<s"m.n"e'giro,"a'.•noa•nt.mes peran.'o"u</ n»m.n.d 22m.a.. *h.m*av Inefona.n®.r^ware^+w94m^,at orMonenM4^^^ww"0.mow, fereswamps �w^^^a+.a^• w.m.N»= -- an.m ria cewr.3. Pw.N;w.. _ a MOP •°°a'hw emrw+a 39920.32 in O.am.0 ar»a gap.mr m .ma.... r.m..aa mxm.naM mane. ear .am... rmw�m eA.mrmrma»mmn.amnm• omm»w am% A008020406 Dan Rhodes LIGHTING CONTROLS (Section UO 2) INTERIOR LIGHTING POWER 6 EFFICACY 1.405 C40510, C405.11) AopHN+Aohaea: 1402 EAR Broad 6tree1 &aeMkY, OH 03000 r<• „ ucsx,x N»e/ pnwp • ...22 m.n„mlawpe.».», -spm 1.1 x.22 ...men. ma uxn 4191 - E.., a.. uo9.s. u0s.s..1 .09.9. z aossl.1 u0sa1. mans m..a» ..anesmp p.". (Sections Pos pt.A fr ..Ir».lugs...3 m".»m�w » .. .. __.____ ......... .. ... Appbren Pl.m: 414-322-]050 ._. _ n PP -sniff bynxp .22 _ -.. _ - n e................ v ipnels is in m Pennons _ _._. - _ Project Description D ...Una O Aewuo la P2022129 O Mos Incl022112.09 uded ,.. .4411, a.anra ."1a mea iq tog » np.bxnr 3.an.101 "p11112=^' °!" w arena el.ve _ 0.192. .awry" eonwa ..._. a _.- .101 ........... ..... Lighting Compliance Path ♦uprare Pomro.eaN Ca O'oas.aroPerlab.Ownon (eT re nam. an only owswm dery m Maximum Allowed Lighting Wattage Rh � g g ..oq� a.. am. a31.an. 202492 4.12 PK.* 1392 rvrw rm»ww. 3. < *v a i n acral Lighting Power Allowance Method sa9202.2.10 999920 2.2.10 •BUHIrp Gree MP. Ospauayswm tA.a3d erialig Ane Lecalionmom ALL 1 a• Area Wads a Ana fm»m';eml *•• c4os.z.:. x omlmav am.wa mem•em pin.e.amuon.....n by enc a-192 » .92.10 uos.tl Lgnrvq Fw+•rca23 �y .annm. W�ubw eem .„ n. .112 par P� »n a»r.o-n.ara nemmd.•nn0011 Rw»wal.memawrM x«.sel., •,vlb ll.v rtlww. nnasen •amp. a.w sus ... •a 41,92 1.33 9v x41 » uasxxa vmnl'm as aypw 'ua+«u+".a•meo, pada+a^^a•eab.+a•yspm Pena. aebsixyymagamloonoar en�w.A ... .. .... Interior Lighting System Description EtrledydwalbelghlIng arae/, lm. aax»»a. ThemterbreOhUn9 system34500 Pis tenant space mnslspsdyoSYYY LED M foewes, mounted wlNN per suspended ce9bg. » c»52x.sa r*ropew ancamFmn r. 210,3 son. nra+M+ay.mee• •m. ......... m�:a,m.tm.,....am- ,.. c1o55.x Avev.reps , 22304 r cm...r...........ants ..... *moo nes I.r4.iN.»ammlwm m...n•a"»waq.m twang woe amwbm. UNA..minor pans Elm • Sol. Table 405.xg(n ai2tt4gee awn drop N.+ mean. motel Proposed Lighting Wattage 912 » c'D5v apr......m swan 0.,.. •. •.Pp»PoP ma.m.N b3.< •0292°39.2•, * ey,ap�ua. e.dsm• a .aasx 6TSP•m s. does. Wese, narnumiabaoa nab Peep Pawns a .p0000( auHrq Ana' Lwano(panp. .... Fn.. Da•mpewY NmM1a fmue• Wade/ flm» Walls P.O..4052] u "^' 1A$ Dewey •^w ...0 6 1WnN au..9 '90 bd.mn .b.. -.200211.- .. p..w..,,anny as m. gl.ro mpxm»m/blew earns wane --- ... ---" EXTERIOR » LIGHTING .05.9.2 POWER 6 EFFICACY (Section C405.M gwN•9wntn.»Nwaam»Nma. Imre 1214...4 mw iaN mm.ma .... ..... ... .0 '''''''''''''''''''''''''.'"'"'"'"'r .snomnyn n pO`an p......am N mrvoiiaa lnaemmmuy gin'2/.929. ea 2920 .... .... .. ....... .... .... ..... Additions and Change of Space Use (1.101.4.3 &1.101.4.4) R.m. nNe9 av,rn ur4x mwFFR 34 z9 410 ®/Walnanama or Change aSwm Use area .wpm,»N»epp9cen. pro4sam eesty3 Mono project p Adak, i -m edsOg building bg10119 systems a den... 001108 rce with al 4591.00 ImWa ne wdO.rGavratDlaspeeseys»mMe3100 0439 -S AG0)comnamnes Fam.2210,3 r R.eae udlp ranmposedpnwuabgexsap be1Wicew•)020010 baba,brAde;Sw or Chen, olu» agues. Provide Aabmbl.dmagmneaa per C406zaammm0e.roip&nglung mbasowe405.44 es 9 ,,,., 413 «wwnd.l �a 22923^^prom ppsesrO .9.. •01 "" -.- wPros...r em4 Wl1wp m pn• xmmw .511 I. 09110.29..20922 mla..helan.»vsw•mt Wlmpr w nSI11 D3mmxynxngmr •92204479 nsamdx n.mawme eymsANa v. 04327.1 ,a.,n, 00434 Fa pins barn (P lu "hat eaowava amrxy (Plump. w«ala5wn 9,e,ea,wy,ayenhasPe .009 rns upabNameo .I»a1ae,.n.ma mmMa9M•m.d espa•»n•aan»a1 of Aping m"° :........ .. .. t»rxam.m»mmn,..0.d.3.ay ....moor, not, m...srasa',.n »..mmrp »»,»mean»a, .gem ... .. ... _....... Repairs C101.4.3.1 Alterations, Renovations and Rep ( ) » umaz aa.»aa+-g raewwmwammmrmam-anew pond.. _ r..."»amm.mm ®aOYran mon a»mawrmaspace 917.& Pmria.Building masinua»6I004re.mad 7r1+vrstnlw$0.1. p•4Maead (U.-WT....CM• wmge um. meay»np...,4 .Ata.num AW"ed Wabay° fable and b.. a ep..cem/= ns».p wMp.inPmpumdwebepe use. Rwoaf•ntI*bet abacus.," be mromenad•epanleN mmpmuap.ama. MOTORS6TRANSFORMERS (sections 1.109.&1.405.9) SoNct rep. w Include ueby Compliance 51(,1 smaw'rpa»bom ing by Building Building 124112 menu. Ae eawna bsfa'pmupnamperrcnroww Area "'' pe„p Dehan aAmra Pan..... •tea r"�'wamm sopa r enof d a"e e1b� u - - - -- F1.alr. m• sm. 0ivn0 1Am m on•"m1».ma... .32922, e.eeeo.»moxb»•nb3wa»ry banns a0c. blowy PP.. »P1se..warnw » &me '�1ddiO1 �� Tr..Imnes P.n.,. �.».e.n aoxaeawm�reaaapem reword 498333•»pa.nsp.2 20 40 u..(I.T 06rsPACE) compliance Ron wbl, n0onlaa•. Dowmanwf»r0 mf voyage wm-rt0O647. swam». In mbpoddeenm.Maximum aro»d Wabaza law. Dmonntprop..1b.waw .xi,apupting»yaom nm',mobbed Wab•pe mos. 8012923 Area Warnings rola AYa.»tl We. Total Pones. Weds mnw L'pnlmg Power news,. tow closzx bleb= 0.0. Mh.s 2 dorsa son022222.If•no•Is indultam..2.101 "".. .... ... mann west and 20. TOTS 290. 0.,01 Ywa 01 tad for an .tees ion rovlde ex•analien. bebb am,.m.n l.mam.m w0m.a anter p.nPo»awnw9.aw ..H..»".130 m. mm.aw.d. 1111 440 COMPLIES • 0 Lamp ae,Imha»are00053 ni0nNOP°hanIm0re43017-wield. totalba.nw Origins wattage nal Poona.000„ tl1' .09.11 G,,,, 488 ni m,idevaca105d3 crPlano Pen 0mmo. P.m le wrn122.1 .y.101urnn p»»lan»pnmm "", 3"r "".olwmv,"p. ".a pow»drg Installed added Snares am». relocated WWI Pm0125. imaYmax,01000p<warier..axz.,I. oo-.rpm<raonsora(c4as.z.zy 070047lsone u,nawa rc40522 ). Specific wn;noorowma(C40s.zzl am ommado»pgflymng ob..be,cws.11 a. .as:..EPP. �" . PP.. SPAN Plens Pe Pions. aping annd Tad ,1.. Pampo,ea Wayaw at»atanireAr»IroaNab 7aIem.dMeb..d W... »swarm Im.r'•m,aa»d.teedlO mpawpem wawem Me rmaa aaa.AU % - D.olpb.n lmimwn ryp type 1..g mal nbbb.,,m,,,b.. b.arl;pntlnppa0alap1name 400 1mn .wm.lem .1.Aar pmpwed WenYFnum u» ontbulac1br. GelMmaxnnum lnput..9. �ab xpdneam secew 0244x51. For i;muwfep.Imrrlgbbrp, ba nreemereraf Tma-nowango Gtalawwl. 48 Ua•8f 229.3 9874.u"wp P,0108,wm».emam .pm... gwors. mml cepwwweill rm.nanim"91nm p rawann..nl bpttlry panel Pwawrowl c co..asnawe.RewMa4.blom.:b.bE01»aa(0405.zzn. .,d<pmmaa;mdrre a v11 445 Oar PP SWOPS Area me. pupa. 70l,e*urga.nma roes... tow b..... .nae.bee/mam dna baum (rot Nma.....mpwnape)...., eanre/lumb.lm»mpeanrerpmabec•mufepeaoy .. .ae.1 `e"w anew mel.,rnbwa.onmm.a,•mrbmm• wm Ude craps, Iss epee., osp.msmm,r3praa b.ww1aes.me»wna..amy Pmuw m.pp..f;sndng<A,oas»ap!. la rvewwrens owmnm;eelaap of Ng.. cons pot' C405. 13. .n.. lunch »p mn.e ry ... �... .are awm»o.gnapmnen• 13Nob.,.are 0argmade PO* die,l9Mt383sp....rtclagad. _ 00001LI•Mln,MwwBTraneom y f�?I'�• `• A[?3 1T D TENANT: verizon 1290-B EAST ARLINGTON BLVD. GREENVILLE, NC 27858 PROJECT PLANNER: WJCA INC. 763 SUSQUEHANNA AVE. FRANKLIN LAKES, NJ 07417 TEL: 201-848-9060 FAX: 201-848-9881 ENGINEER: Dan R. Rhodes, PE 7402 East Broad Street Blacklick, Ohio 43004 Phone: 614.204.2479 MEP Building Consultant PROJECT LOCATION: SOUTHCENTER MALL SPACE#354 1240 SOUTHCENTER MALL TUKWILA, WA 98188 ISSUED DRAWING LOG NO. DATE DESCRIPTION 12/22/17 ISSUED FOR LL APPROVAL / PERMIT 1/4/18 ISSUED FOR PERMIT PROJECT NO: 0 `3' ,. • DRAWING NO: E-102 C'AERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0012 PROJECT NAME: A WIRELESS SITE ADDRESS: 1240 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # DATE: 01/12/18 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: it 4t/JC kg -to 4 AWC V0 M0 AY/4- Building Division s �s N/A— 11(e61(0 Public Works Ng Fire Prevention 111 Planning Division No Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER0S INITIALS: DATE: 01/16/18 Structural Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: Approved ❑ Approved with Conditions Corrections Required ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: 02/13/18 REVIEWERS INITIALS: DATE: Permit Center Use Only CORRECTION LEITER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 M P I AMERICA LLC 1-lom,ne Espanol Contact Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries Search L&I Page 1 of 2 A -Z index Help My1..&3 Workplace Rights Trades & Licensing M P I AMERICA LLC Owner or tradesperson Principals POWELL-PHELPS, TONY L, PARTNER/MEMBER MESSERLY, DARREN R, PARTNER/MEMBER Doing business as M P !AMERICA LLC WA UBI No. 602 290 368 1836 SE TENINO ST PORTLAND, OR 97202 360-693-5735 Business type Limited Liability Company Governing persons TONY LANDON POWELL PHELPS JENNY GROVE; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. MPIAMPI952L8 Effective — expiration 06/28/2005— 08/14/2019 Bond Western Surety Co Bond account no. 62771058 $12,000.00 Received by L&I Effective date 05/04/2016 05/05/2016 Expiration date Until Canceled Bond history Insurance ...... ............. Developers Surety & Indem Co $1,000,000.00 Policy no. BIS00022046-03 Received by L&I Effective date 04/20/2017 05/05/2017 Expiration date 05/05/2018 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602290368&LIC=MPIAMPI952L8&SAW= 2/7/2018 M P I AMERICA LLC Insurance history Savings ........................ No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. f \ Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 101,353-00 Account is current. Doing business as MPI AMERICA LLC Estimated workers reported Quarter 4 of Year 2017 "Less than 1 Workers" L&I account contact T1 / TYRONE COLEMAN (360)902-4807 - Email: COTI235@lni.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes ......................................._.............. No strikes have been issued against this contractor. Contractors not allowed to bid ............................._............................................._........... No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 c5 Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602290368&LIC=MPIAMPI952L8&SAW= 2/7/2018