Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D18-0051 - OSUM EVENTS RENTALS - STEEL PALLET RACKS
OSUM EVENTS RENTAL 730 ANDOVER PARK E CA NCELLED/WITHDRA WN 12/11/18 D18-0051 Parcel No: Address: Project Name: 0 City of Tukwila 0 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: httD://www.TukwilaWA.gov 2623049095 730 ANDOVER PARK E OSUM EVENTS RENTALS DEVELOPMENT PERMIT Permit Number: D18-0051 Issue Date: 3/23/2018 Permit Expires On: 9/19/2018 Owner: Name: Address: Contact Person: Name: 790 ANDOVER LLC PO BOX 287 , MEDINA, WA, 98039 MATT PREVOST Address: 500 SW 16 ST, RENTON, WA, 98057 Contractor: Name: MR RACKS Address: License No: Lender: Name: Address: ,,1 OSUM EVENTS RENTALS 730 ANDOVER PARK E , TUKWILA, WA, 98188 Phone: (425) 207-0057 Phone: Expiration Date: DESCRIPTION OF WORK: REISSUANCE OF EXPIRED PERMIT D16-0130 STEEL PALLET RACKING Project Valuation: $15,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $670.83 Occupancy per IBC: B Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: 3-Z3 4e I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: wv fr--" J c5`---- l '7-3/ ( � Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 10: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 11: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 12: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 14: Maintain fire extinguisher coverage throughout. 16: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 17: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 18: Clearance between ignition sources, such as light fixtures, heaters and flame -producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 19: Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one-hour fire proofing, (b) sidewall sprinkler at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 13-16.1.4) 20: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.3.1) 21: Flue spaces shall be provided in accordance with International Fire Code Table 3208.3. Required flue spaces shall be maintained. 15: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 4046 SI-EPDXY/EXP CONC 9,4 CITY OF TUK0 Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov OSUI64eel Building Permit No. t) - r� s Project No. Date Application Accepted: Date Application Expires: 3-----1 g (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 73o of (l—P K_E King Co Assessor's Tax No.: 2-b 2-3 0 l 0 l..C. Tenant Name: 05LAM 1�11� 5 PROPERTY OWNER Name: 7 Q o ickNoo v vrn_LL_C- . Address: '1 !, O p` 0 , Cf,- T i'- a Cityi) tux.)te,1 bc} State: (it%pr. Zip: 9e(86 CONTACT PERSON - person receiving all project communication Name: l - �- '- 9 � .D S"� Address: 50 0 3 LJ 1 (c - t City: p „3 J . State: Zipct g0r-"1 Phone: c L ' ^1 _0 b x: L! 2 S- 231-501 I. S^ Email: org- it.�Y . ArCo,� . co ,A... GENERAL CONTRACTOR INFORMATION Company Name: ,/Z 6 (j 12-- �(J Address: 5b 0 ALA..) ( S+_• City: �4J State: ZipG Ds -- SPhone:t4;2..� Phone: t4;2..c....'2,0)_0()gaax: L yS-2ifl-s01 k Contr Reg No.:60 79 01 L4 Exp Date:lm6 n J10 123 Tukwila Business License No.: bus _ dig 5 L s 6 H:\Applications\Forms-Applications On Line\2011 Apphcations\Pemrit Application Revised - 8-9-11.doox Revised: August 2011 bh Suite Number: Floor: Cew Tenant: 0 Yes Nc) ARCHITECT OF RECO Company Name: (ZQ ss L li .-n-iv Engineer Name: avotsI L ( Liv tG9r- ills, Company Name: w �/�_ I"� t- Phone: �7 _ j _ g.7 �_ 73 ax: A..) i ( Architect Name: In�-' Address: h) I / 1(tAr City: I State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Company Name: (ZQ ss L li .-n-iv Engineer Name: avotsI L ( Liv tG9r- ills, Address: 2-1 1 ZZ i 2_6 4•. 1 _S C City: 4__ State: WA- Zip�8O31 t- Phone: �7 _ j _ g.7 �_ 73 ax: A..) i ( Email: --t-4 L, (2_ _ G O L7 -P / --7 • j� 12 LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: UVa• GJ fJ Address: 01 In�-' CitY:li 1(tAr State: Zip:C Q ! g Page 1 of 4 of g BUILDING PERMIT INFORMATIO206-431-3670 OC.) Valuation of Project (contractor's bid price): $ � 51 COD Existing Building Valuation: $ Describe the scope of work (please provide detailed information): Will there be new rack storage? Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) w FIs ('� 0 3co Sc� F-�-- *For an Accessory dwelling, provide the following: Lot (sqAreaft : i0 6/ OW b Floor area of principal dwelling: Floor area of accessory dwelling: ) P P g" n *Provide documentation that shows that the princi al owner lives in one of the dwellingas his or her primary residence. Number of Parking Stalls Provided: Standard: 1 Compact: Handicap: f Will there be a change in use? ❑ Yes No If"yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers 0 Automatic Fire Alarm ❑ None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No If 'yes', attach list of materials and storage locations on a separate 8-12"x 11 " paper including quantities and Material Safety ata Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Upplicatbn\Forms-Application On Ln ee2011 ApplicationsWermit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1a Floor (Lll 0 V (O fMvIL 2d Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) w FIs ('� 0 3co Sc� F-�-- *For an Accessory dwelling, provide the following: Lot (sqAreaft : i0 6/ OW b Floor area of principal dwelling: Floor area of accessory dwelling: ) P P g" n *Provide documentation that shows that the princi al owner lives in one of the dwellingas his or her primary residence. Number of Parking Stalls Provided: Standard: 1 Compact: Handicap: f Will there be a change in use? ❑ Yes No If"yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers 0 Automatic Fire Alarm ❑ None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No If 'yes', attach list of materials and storage locations on a separate 8-12"x 11 " paper including quantities and Material Safety ata Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Upplicatbn\Forms-Application On Ln ee2011 ApplicationsWermit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTH D AG Signature: Print Name: Viv r p Sr"-. ,� Mailing Address: 50D 51—k) l (v 4� 9k— City Day Telephone: H:UppliationslFonns-Applications On Line\2011 Apptiwtions\Permit Application Revised - 8-9-11.doex Revised: August 2011 bb Date: V " l 14'1L 2—/ la v (+LS— State Zip Page 4 of 4 MLA 14/ Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $670.83 D18-0051 Address: 730 ANDOVER PARK E Apn: 2623049095 $670.83 DEVELOPMENT $651.23 PERMIT FEE R000.322.100.00.00 0.00 $391.96 PLAN CHECK FEE R000.345.830.00.00 0.00 $254.77 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $19.60 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R13915 R000.322.900.04.00 0.00 $19.60 $670.83 Date Paid: Friday, March 02, 2018 Paid By: MR RACKS Pay Method: CHECK 7872 Printed: Friday, March 02, 2018 8:54 AM 1 of 1 l?SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION p17-0051 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 USuM EY Zlf'i r Approved TtAn 14eltion: Fl tau, Address: —730 AplAin r i E. Date Called: Special Instructions: Date Wand: '7te``7-Z a.m. Requester:p r i rV�, I(-' Phone No: -73 5 / — 206 — 6-73--67),3— Approved per applicable codes. COMMENTS: L7L/ Corrections required prior to approval. Inspector: E (wCa, Date: 7 l ., _ _/ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Calt to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit D15 -DOS 1 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: OSIAM EV S S Ty a of Inspection: i? ti tat 'Fi,JAL Address: -1(30 A1/4riCkief" P/444( E. • Date Called: Special Instructions: 1,v _ 3 j�/►I 1 Date Wanted: a.m. & — PI— Zai/E-- p.m. Requester: 1'V(a�� y� �t- Phone No: wG 3- 73 5056- t__J Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: 1.k c..c( exe-, 1. AkA20 K.r olype}viAL Date: / - REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION big - f 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: OSU ti E,e' 1s giOc. Type of Inspection: Szi, a." ?al( Y Address: 7:3r) oLe(T ar k. Date Called: Special Instructions: Date Wanted: /oo Q� a.m. �—'�'zp.m. Requester: r _i LA ()15o2*• X75 sag - Approved per applicable codes. orr ions required prior toapproval. C MMENTS: 61", rAfrqitakrY (,)/ LOA' &rtsf Inspector: 73 O Date REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPE TION RECORD Retain a copy with permit'' PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:)U a �� A Sprinklers: '7" ? Type of Inspection: ,/"'/ Address: #: �� per ontact Person:Suite Special Instructions: Pre -Fire: N "5 Occupancy Type: IA)A4� -C2\i Phone No.: s I Approved per applicable codes. k' rrections required prior to approval. COMMENTS: m o vr rafro 5 7P/7$ 710 67/L0.vN4 No MfrtE2- �I'l/TyJ Needs Shift Inspection: I 1 Sprinklers: '7" ? Hrs.: Fire Alarm: ki* 5 Hood & Duct: Monitor: Pre -Fire: N "5 Occupancy Type: IA)A4� -C2\i e----- Permits: i Inspector: rim S (,---' Date: ha.% `-j Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 A.A. Testin Field Report Report #: 75119 Laboratory`, Inc 7136 i$Oth Ave N' ,Park'f80,asttlte Ciba, Redmor _Phone 425:$81.5812 fax 425.881: Client: Mr. Racks 500 S.W. 16th St. Renton, WA 98057 Contact: Carey Ferguson/Matt Prevost Project Number: 18-466 Permit #: Project Name: Address: D18 0051 Osum Event Rentals 730 Andover Park E. Inspection Performed: Proprietary Anchors Date: 6/12/2018 Time: Temperature: Anchor bolts for relocated pallet racks, 8 bays Verified installation of Simpson Strongbolt 2 anchors 1/2" x 4 3/4" with 3 1/4" embed, torqued to 60 ft./lbs. All installed per ESR 3037 and per plan. RECEIVED CITY OF TUKWILA JUL 11 2018 PERMIT CENTER Distribution: ❑ Distribute Client ❑ Distribute Contractor ❑ Distribute Engineer ❑ Distribute Owner 0 Distribute Municipality ❑ Distribute Other ❑ Distribute Architect ❑ Distribute Other Inspector: Trow, Michael Reviewed by: Michele Guerrini All reports are considered confidential and are the property of the client and A.A.R. Testing Laboratory, Inc. Reproduction except in full without the written consent of A.A.R. Testing is strictly forbidden To: City of Tukwila Dept of Community Development Attn: Bill Rambo From: Mr Racks LLC Attn: Matt Prevost Regarding: Osum Events # D18-0051 Bill Dec 11, 2018 I would like to request to have Osum Events pallet rack permit #D18-0051 cancelled. They have vacated their space on 730 Andover Park E completely and have remove all rack fixtures. Thank you Matt Prevost Mr Racks LLC RECEIVED CITY OF TUKWILA GEC 1 1 2018 PERMIT CENTER 12/2/2018 © 0 City of Tukwila Department of Community Development MATT PREVOST 500 SW 16 ST RENTON, WA 98057 RE: Permit No. D18-0051 OSUM EVENTS RENTALS 730 ANDOVER PARK E Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 1/14/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 1/14/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, tLldY Permit Technician File No: D18-0051 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 9ERMIT CORD COPY d PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0051 DATE: =03/02/18 PROJECT NAME: OSUM EVENTS RENTALS SITE ADDRESS: 730 ANDOVER PARK E X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division Public Works 3-748 >�W1All4c %-m--f Fire Prevention Structural Planning Division ❑ Permit Coordinator or PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 03/06/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required DUE DATE: 04/03/18 ❑ Approved with Conditions ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping 0 PW 0 Staff Initials: 12/18/2013 �a o City of Tukwila Planning and Development Osum Events / Tukwila Permit Application: Osum Events / Tukwila To whom it may concern, The engineer who did the structural calculations has requested a special inspection of the wedge anchors for the pallet rack. I looked for a form to fill out with this information, could not find. So please see enclosed below Engineer: Rack Design and Engineering 412 West Broadway #204 Glendale Ca 91204 Attn: Garnik Ohan Lisc # 33552 Expiration Date: 12-26-2018 We are contracting with AAR Testing of Redmond Wa to do the special anchor inspection. AAR Testing PO Box 2523 Redmond Wa 98073 Attn: Michele Phone # 425-881-5812 Thank you Matt Matt Prevost Auto Cad and Sales Mr Racks LLC 206-697-1241 b ($- 0051 RECEIVED CITY OF TUKWILA MAR 0 3 2018 PERMIT CENTER MR RACKS LLC 45 Washington State Department of Labor & Industries 0 Home Espanol Contact Safety & Health Claims & Insurance 0 Search L&I Page 1 of 2 SEARCH A -Z Index Help My L&I Workplace Rights Trades & Licensing MR RACKS LLC Owner or tradesperson Principals Ferguson, Carey Scott, PARTNER/MEMBER Ferguson, Julie Lynn, PARTNER/MEMBER Ferguson, Carey Scott, AGENT GONSER, BRETT, PARTNER/MEMBER (End: 04/30/2013) MCLENDON, ROBERT, PARTNER/MEMBER (End: 04/30/2013) Doing business as MR RACKS LLC WA UBI No. 602 779 014 500 SW 16TH ST RENTON, WA 98057 425-207-0058 KING County Business type Limited Liability Company Governing persons CAREY FERGUSON JULIE FERGUSON; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. MRRACRL924BN Effective — expiration 01/03/2008— 01/17/2020 Bond AMERICAN CONTRACTORS INDEM CO Bond account no. 100031015 $12,000.00 Received by L&I Effective date 01/03/2008 12/20/2007 Expiration date Until Canceled Insurance Ohio Security Ins Co $1,000,000.00 Policy no. BKS 54574031 Received by L&I Effective date 06/22/2017 06/29/2017 Expiration date Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602779014&LIC=MRRACRL924BN&SAW= 3/23/2018 Sc C PE F 0 a Seis ic Ca c ceZ Number: 2623049095 LE AL F #5 T C 247F o�nstall (22) ations, Specie ays Anch I�,cSCr II''d'IN: NE 1/4 F SE 1/4 EG S� �1-47-28 `,`. 545 FT TPE T LFT 50 FT C/ TI N 014728 E 42227 FT Pallet ack 48" r Inspection req 8AN � 9O00I0 T LY T 1 ep x 144" 1 .d fer al y wed e x 23' TalL e anchrs, IRT�IoUSTL S 01-4728 �%V%V 372.27 F ITT F,RC FIST 78.54 FT T TLESS iIP King County I0tI0; upptaIowa. OoUtor lyrrl ip The Information Included on thls map has been complied by King County staff from a variety of sources and Is subject to change without notice. King County makes no representations or warranties, express or Implied, as to accuracy, completeness, timeliness, or rights to the use of such Information. Thla document Is not Intended for use as a survey product. King County shell not be liable for any general, special, Indirect, Incidental, or consequential damages Including, but not limited to, lost revenues or lost profits resulting from the use or misuse of the Information contained on this map. My sale of thls map or Information on this map Is prohibited except by written permission of King County. Date: 2/23/2018 !SI King County GIS CENTER tans SEPARATE PERMIT REQUIRED FOR: fJ4 chanicat Electrical bing rWtas Piping Cliy of Tukwila BURPING DIVISION R�lSIONS No changes shaq`e m de to the scope of work tlritliout prior approval of Tukwila Building Division. I PNOT: (-;clr;sions will require a new plan submittal I and may include additional plan review fees I FILE COPY Permit No. 19 - 00 5' I Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy an c banditions s acknowledged: By: Date: 312312..o1 B City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 2 2018 City of Tukwila BALL D1Nf; y RECEIVED CITY OF TUKWILA MAR 03 2018 PERMIT CENTER 8 b co CS) 6c1 inia4ch U toCJ U o [r o E. ua oDa U4.3 Lza 1 0. Nw �000 ci_ lIx w ©'� O >-- W z 4 g QC — V)re) q ©r- • i—o DRAWN BY: KHDA SCALE: 3/16" = 1' DATE: 2-19-2018 DRAWING N0: CRECOD BY: 9•• oos� SHEET N0. 1 OF 2 SHEETS 33'4" 7-7 7-7 EXIT LI 39'-4" NOTES: 1. ALL PALLET RACK POSITIONED TO LEAVE A 6" FLUE SPACE MINIMUM ON ALL SIDES WHEN LOADED. 2. SHELF SUPPORTS ARE (6) 2" x 6" WOOD SUPPORTS - 3. WAREHOUSE AREA IS APPROXIMATELY 14,086 SQ. FT. 4. WAREHOUSE IS EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM ADJACENT TENNANT THIS SIDE 39'-4" 391-4" 391-4" 23'-2" 24'-111 4 49'-534" 48" X 120" 48" X 120" 48" X 120", ® 48" t 1 ® 48" X 144" 0 48" X 144" ® 48" X 144" EGRESS PATH 87' 6'-6" ® 48" X 144" ® 48" X 144" 48" X 12r 11-0" — 118'-0" ® 48" X 14 " ® 48" X 14 4" 10" EGRESS PATH 129' 48" X 144" \'7 27'-2" l'-0" 30'-10" 33'-1" 391-4" 39'-4" 39'-4" BATH BATH 0 - X 24'41-1" 4 49' 5- 4 ADJACENT TENNANT THIS SIDE 39'-4" 231-2" REVIEWED FOR CODE COMPLIANCE APPROVED MAR 22 2018 City of Tukwila ozH 500 SW 16TH ST E RRM MAE RCI ToE CI3VE2E0NDI T8 E R fiTy OF TUKWI A P DRAWN BY: KHDA SCALE: 3/16" = 1' DATE: 2-19-2018 DRAWING NO: CIIRCIND BY: HUT NO. OF 2 SHEETS SIDE ALL FRAMES TYPE 3/8" THK 3.11" 12' FRONT TYPE "A" UPRIGHT COLUMN — FLOOR ANCHOR DETAIL SEE NOTES FOR. SPECS MIN. (TYP.) 12' c FRONT TYPE "B" ELEVATI 10' 1 NO STORAGE THIS LEVEL TRUCTURAL SUPPORT ONLY NS SCALE: NONE DIAGONAL BRACE (TYP.) 1/8" HORIZINTAL BRACE (TYP.) BRACING CONNECTION DETAIL 5/8" 0 HOLE (TM BASE PLATE DETAIL 10' 5 NO STORAGE THIS LEVEL TRUCTURAL SUPPORT ONLY FRONT FRONT TYPE "C" TYPE "D" .375 R CO/I() CO 3., 2" TYP. AS NOTED 1-1/4" REF. 0 0 CI COLUMN DETAIL I 1/2" I 14 GA 1 1/4" RI/8" COLUMN STRUT TYP. AILS SCALE: 3" = STRUCTURAL NOTES: 1. RACKS ARE MANUFACTURED BY LODI METAL TECH (LMT) OF LODI, CA OR EQUAL 2. MINIMUM YIELD (Fy) AND ULTIMATE (Fu) STEEL STRENGTHS SHALL BE AS FOLLOWS: (a) BEAMS AND COLUMNS Fy=50ksi Fu=65ksi. (b) BASE PLATES FY=36ksi Fu=58ksi. 3. MAXIMUM RACK LOAD PER LEVEL PER PAIR OF BEAMS SHALL BE AS FOLLOWS: (a) PALLET LEVELS: 2500 LBS (b) HAND STACK LEVELS: 1000 LBS 4. CONCRETE SLAB IS GIVEN AS 6" THICK WITH fc'=2,500 psi. 5. ALLOWABLE SOIL BEARING PRESSURE IS GIVEN AS 1,000psf FOR GRAVITY LOADS. 6. TIE -DOWN ANCHORS SHALL BE SIMPSON STRONG BOLT 2 WEDGE ANCHORS. USE TWO (2) 1/2"0 X 4-3/4" ANCHORS WITH A 3 1/4" EMBEDMENT PER BASEPLATE ESR 3037 SPECIAL INSPECTION IS REQUIRED. 7, POST LOAD SIGNS NOT LESS THAN 50 SQUARE INCHES IN AREA SPECIFYING THE DESIGN CAPACITY AT CONSPICUOUS LOCATIONS. 8. IF ANY DISCREPANCY OCCURS, CONTACT THE ENGINEER FOR CLARIFICATION. 9. ANALYSIS AND DESIGN OF RACK CONFORMS TO THE 2015 IBC SEC 2209, RMI 16.1:2012 CODE, AND SEC. 15.5.3 OF SEI/ASCE 7-10 USING THE ASD METHOD WHERE: FIRE PROTECTION NOTES: I. SPRINKLER SYSTEM IS .395 GPM OVER 5,600 SQ. FT. UTILIZING 286° HEADS 2. TYPE OF PRODUCT: EVENT AND PARTY RENTAL EQUIPMENT 3. TOP OF STORED PRODUCT NOT TO EXCEED 18'-6" 4. APPROXIMATE CEILING HEIGHT 26'-0" EXITING NOTES: 1. EXTERIOR DOORS ARE 3' SWING TYPE WITH LOCKING KNOB WHICH REQUIRES NO SPECIAL KNOWLEDGE OR EFFORT TO OPEN. 2. EXTERIOR EXIT DOORS TO BE MARKED PER APPLICABLE CODE BRACKET ASSY. TYP "NNBEAM SECTION 14 GA THK. ASTM A572 GR50 BEAM DETAIL FOR 10' SPANS TYP. AS NOTED 6" EXPIRES 12-26-19 BRACKET ASSY. YP BEAM SECTION 14 GA THK. ASTM A572 GR50 BEAM DETAIL FOR 12' SPANS REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 2 2018 City OfTukwila i-nitko!,177,1yr, TYP. RECEIVED CITY OF TUKWILA MAR 03 2018 PERMIT CENTER 04 to co) ern) L-1-5 J co < 00 L.L.1 CL_ cy) CC CC • (/) LLJ 0 M C.) (Y) te) DRAWN BY: KHDA SCALE: AS SHOWN DATE: 2-19-2018 DRAWING NO: CHECKED BY: B. Kattula SHEET NO. 2 OF 2 SHEETS