Loading...
HomeMy WebLinkAboutPermit D18-0063 - COMEAUX RESIDENCE - BATHROOM, OPEN LOFT / KITCHEN AND CLOSE UTILITY ROOMCOMEAUX RESIDENCE 13544 35 AVE S D18-0063 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov 8864000045 13544 35TH AVE S Project Name: COMEAUX RESIDENCE DEVELOPMENT PERMIT Permit Number: D18-0063 Issue Date: Permit Expires On: 4/13/2018 10/10/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: OXENRIDER WESLEYJ 13544 35TH AVE 5 , SEATTLE, WA, 98168 NICHOLAS COMEAUX 14508 NE 20 ST - SUITE 200 , BELLEVUE, WA, 98007 OWNER AFFIDAVIT- NICHOLAS COMEAUX Lender: Name: JMD INVESTMENTS LLC Address: 14508 NE 200 ST - SUITE 200 , BELLEVUE, WA, 98007 Phone: (425) 457-4549 Phone: Expiration Date: DESCRIPTION OF WORK: COSMETIC REMODEL, ADD BATHROOM UPSTAIRS AND OPEN UP LOFT. OPEN UP KITCHEN AND CLOSE OFF UTILITY ROOM. Project Valuation: $32,000.00 Type of Fire Protection: Sprinklers: NO Fire Alarm: NO Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $1,231.35 Occupancy per IBC: R-3 Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-468: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Pikibl Vii)11/1(' J Date: 4 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: \\I:(A.A r Date: (1A -1K This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 8: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one-third and lower one-third of the water heater's vertical dimension. A minimum distance of 4 -inches shall be maintained above the controls with the strapping. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0409 FRAMING 0606 GLAZING 0603 ROOF/CEILING INSUL 0601 WALL INSULATION BUILDING PERMIT INFORMATIOr 1O6-431-3670 Valuation of Project (contractor's bid price): $ 3 2---,0&0 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): llS,�,�J; e-.���1 ( ‘1d1 L14 (1-40 4- orb. vr 6)-/Je-� •�Gv vim` I (,sc ,k -f,4 / Will there be new rack storage? ❑ Yes yr rvh D .. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers 0 Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1' Floor 2nd Floor 7-6\ 4 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers 0 Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMITINFOIiATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑ ...Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate 0 .. Highline ❑ ...Valley View ❑ .. Renton 0... Sewer Availability Provided 0 .. Renton ❑ .. Seattle Septic System: 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) 0 ...Bond 0 .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way ❑ 0 ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities 0 ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Geotechnical Report 0 .. Maintenance Agreement(s) ❑ ...Traffic Impact Analysis ❑ ... Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank 0 .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line 0 ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public 0 ❑ ...Water Main Extension Public 0 91 WO # WO # WO # Private 0 Private 0 ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Deduct Water Meter Size FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) 0 ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES – �+wr Auk Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review – Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN R OR AUTH Signature: Print Name: N ol-wil <s C G € a v� Mailing Address: 14 8 N 54 1j-2 H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Date: ��-1 V Day Telephone: NI? °15'1- —YSY YG 1l evv.e City State Zip Page 4 of 4 DESCRIPTIONS PermitTRAK Cash Register Receipt City of Tukwila ACCOUNT QUANTITY PAID 1,231.35 D18-0063 Address: 13544 35TH AVE S Apn: 8864000045 .231.35 DEVELOPMENT $1,195.27 PERMIT FEE R000.322.100.00.00 0.00 $721.68 PLAN CHECK FEE R000.345.830.00.00 0.00 $469.09 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $36.08 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R13962 R000.322.900.04.00 0.00 $36.08 $1,231.35 Date Paid: Thursday, March 08, 2018 Paid By: JMD INVESTMENTS LLC Pay Method: CHECK 1503 Printed: Thursday, March 08, 2018 2:22 PM 1 of 1 I?WSYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit �I c063 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: tea, E .)( Af1-1 Type of Inspecti n: 1/31114.1Z 641 -- Address: 433-1/4 3511 s Date Called: Special Instructions: Date Wanted:_ / •//'/k p.m. Requester: Phone No: Nri6 COMMENTS: c g�lc_.o ,✓h. ��� pproved per applicable codes. LJ Corrections required prior to approval. Inspector: Date: d—M 4 —t 1 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 _0b3 Project: t n COMeAtAX ,c,Vr T e of I` sp Abu.,1C tion: r /hL Address: i15-9/1 35*-vcsS Date Called: Special Instructions: Date Wanted: Req sten: Phone 9z5 577- 9/2S Approved per applicable codes. Corrections required prior to approval. COMMENTS: A_ .ccit.ewuk Inspector: :_-c:2 Date// _ ze/sr.„,- REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: CDrn em G Typef Inspection: �14 74JSuL.'h,bY) Address: /35/PI c_35* Ave. S, Date Called: Special Instructions: Date Wanted: a.m. 7-tz 2.01fS p.m. Requester: IV SCK Phone No: II —1/57- 1-/51. 1.9 ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector:760 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 PPjeect: ®� 7�� : Type f Inspection: i�nprz ldA3c_�d�%rey6;I ��jS: Date Special Instructions: 1 nV-.0A/` Date Wanted: a.m. `�� a.m. p.m. l Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. C OMMENT s*P4CSS OkAivv`104CS • a -e S LACKI-Zg ckeitile_tvLsprAo\lt Inspector: 0.,7 rya' REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit Di 3 -0663 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: (:pMLf Ct,c 9( Type Inspection: 9*"✓ 4M I egi- Address:Date Trfi 35'1/y 35 , Called: Special Instructions: -rat/11104/ Date Wanted:�p� 7-3— m. /m. Requester: Phone No: j X� Approved per applicable codes. COMMENT • _ E] Corrections required prior to approval. "119 oma. erd (7‘.(a otiska, -TV ;-r" AL5 Q-C-coki inspector: Date: �J REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: tam1 il,>o Type of Inspection: Erb l0 Address: M !3Sµ4 35 &IL Si Date Called: Special Instructions: O ck. _ Date Wanted:7 —2_ a,m p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: ece it th_5 / M 4i aut.."( riK b011 -v)41 s � Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit DI -&Z3 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: mom^ , 'x Type of Inspection: frrIfil fey Address: `3syy 35 �. Date Called: � Special Instructions: Dat Wanted: _ �q (0 z8 z.g/ \d•-� p.m. Requester: Phone No: CApproved per applicable codes. COMMENTS: Corrections required prior to approval. 04-10ack ee Aouso 441 rte' (F) € 4e O Z,) c4 -Orn 1J 5 9 _ e"l a,LL beam/ dooe S cod tS/OV, 0-kveha (v, A x bD//M L ad-S?49-r K, Inspecto Date:/ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. SEPARATE PERMIT REQUIRED FOR: GechaniCW electrical [dumbing s Piping G iy of Tukwila , 12110 DIVISION 5 1" 7'-113" Height 4' 5" WSH 2'4" 11'0}" 6'-11}' 1'-7' 1 2'-53" / 3' 8}" / 10. 23" FILE C Permit No. 5-43" 3' 1 —14 1 714— 2' 5}" 8' 5 '-107" 4'-11" T Height 6 1/2" WSH6'11/2" 0 3'-33" 1-11" -- 2' 57' - 2'-4" 2'-2= 10 27' 13' 43" 1'-4"'7 Height 3' 5" 4' 7i' —T WSH 3'31/2" Height 4' 5' WSH 2'4" 'f2'5?— 2' 9" —� 7' 6? 2'-11? f-2'-13"-71 *--3'11" A' 2' 6„ —71' 3' 10? 2' 4 2'-37" 3' 1? --74 101/7 runner 1 2%6" 4 87 —74 Plan review approval Is subject to a omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Feld Copy and conditions is acknowledged Date: _j/34' s- City of Tukwila BUILDING DIVISION Height 4'51/2" 4' 97' W51-1 2'3" 11'-117" 0 Height 1' 6 1/4" WSH 3' 7" 5' 27' 14'53' r 6' 5?" 6' 117" 1'-77" 13' 73" 9,-2}" 4' 33" 7= 17' 21" Height 4' 4" W511 2' 31/2" 2'-33' 1st Floor As—Built 1/4" = 1-0" REVISIONS No changes shall he made to the scope of work without prior approval of Tukwila Building Division. NOTE: €ieviskons will require a new plan submittal and may include additional plan review fees. REVIEWED FOR CODE COMPLIANCE APPROVED APR 12 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 1 1 2018 PERMIT CENTER CORRECTION N LTR# 0 0 1n cn Q : W CO Z 8j O 010 000) 0 0 C v� N 00.0 c >00 0 W (I)0) Z NN 00M I 0 9') r Residence tn� 01 • > 0 Q� O 00 0 (7 to min � fA Q No. Revision/Issus Date 01 As—BuAt 02/23 • 000 Coto 02/23/18 9' 8+" 12' 1}" 8,_10+" 3'-1 6' 2" 8' 6}" Roof Line on Ceiling 11' 9' f—- 5, 2+" 6' 5' 7+" 2' 4" 3' O„ -FA 12' 1}" 1,_10+" 2 4'-7+" 2'-1}" 1'-2+" Demo Walls 5' 5+" 2.4 3'-2+" 6,_8+" f— 3,_4" —f • 13' 5+" 2nd Floor As—Built 1/4" = 1'-0" RECEIVED CITY OF TUKWILA REVIEWED FOR CODE COMPLIANCp APPROVED APR 12 2018 City of Tukwila BUILDING DIVISION APR 1 1 2018 RMiTa`7 i .. .1 E fR fi 2 O O N qkQ C N �o c >00 0Z Cr) 0) N 00 m = O r Residence cnCn > 0 vat 0 0D v LD M 3 0, m 4- cn are) No. Revision/18804 Date 01 As—Butt 02/23 1 000 Dot* 02/23/18 Sod P2 9 7'-11*" Safety Glazed Height 3' 5" WSH 4' Height 4' 5" y` 5'-1" / WSH 2' 4" 4 -- Height 3' 5" WSH 3' 3 1/2" 13'-4*" 1'-4" / f-- 4'-7*" 6'-11}" 11'-0*" EN 1 -1,-- 121 f- 3'83"-4 3'-1�a" —/- 2,44,E 1'-11" 1 -1k--- 2'-5i" — Bed Room 0 '-11" 8'-5 1'-10*" \A, 7'-5*" 2'-4" or 3'-3*" —� 5'-41r" 10'-2*" 2'-4*" e 3 0 0 Bath Room 6-8*" Bed Room CD Al-- 2'-5}" —714 -2 Height 4' 5" t_ WSH 2'4" 2'-Oa"—� f f---- 5'-2*" 00•00 2'-1*" 5'-0* ' 3'-10*i' '-5 10'-2*" 2'-3*" / _ l 3'-111" ---/ 7'-9*" 10 uz• runner 2'-6" 4'-8 /-- 4'-9*" —� 11-11*" Height 4' 5 1/2" WSH 2'3" 1,9 3' Kitchen New Walls 3'-11 " --714 -+ 3'-4„ ►� • • •4 • • • • • • 1'-9*" om 7'-5$" 14' 5i Living Room f-- 5'-2b" 6'-5*" l' -7i" 6'-11*" 2'-9*" X N it) � 13'-7's" 9'-2*" 4.-3r" —� 1 7'-2*" Height 4' 4" WSH 2' 3 1/2" 2'-3*" 1st Floor Proposed 1/4" = 1'-0" RECEIVED CITY OF TUKWILA REVIEWEDFOR CODE COMPLIA APPROVED APR 12 2018 City of Tukwila BUILDING DIVISION PR 1 1 2018 IT CENTER 0 0 CV to tno` y Cr)oQ CO W z0 C t10 jr o 0 a Gmco 0 0 CV v o LQ 00 >0 w sT Z CD co U.1 = 0 In • No. Revision/Issue Dote 01 As—Butt 02/23 02 Proposed 03/05 Dges P1J Impot 000 03/05/18 Ude , /4.•=1.-0 1 8'- 3'-13" 3'-3i" 2'-5**" 9'-83" 12'-1}" Bed Room Roof Line on Ceiling 8'-6*" 1'-103" pe-- 5'-2i" Attic 2,�,� 3 03 -14 12'-1}" Attic 1'-7} 12'-10" %`:` ale We ,"t� Y' Loft Room New Walls 7' 83" 2'-3$" 1' •&• •A♦ •&.'&:••� 5'-5}" 4' 6" 1'-9" 2,-4" -23 • 4' 4 Bath Room 0 111 0 2'- 1'-03" V V WWWWW VVIP VVVVV eV • 9'-4*" 2nd Floor Proposed 1/4" = 1)-0)' 7' - N� 0L 7 V% 1'-6*" ._ 1REVIEWED FOR C'ODE COMPLIANCE APPROVED APR 12 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TIJKWILA APR 1 1 2018 PERMIT CENTER 0 0 CV 03 4k 07 -c (5 Q : W m Z O) o O CO 00) 0 0 N L �Q c-3 p 4-O, N > 00 oW Np) Za) 0 00 m s0 in Residence No. Revision/Issue Date 01 As—Butt 02/23 02 Proposed 03/05 wop 000 0 03/05/18 lode �1 /4'-1'-0 1 P 2) J New Walls (TYP.) x( ( RifsfP ert y e (41 170 #" ioIo 2x8 Rafters Orig. Walls (TYP.) Unused Space CA) Loft Cross—Section 1 /2" = V-0" 2x8 Joists REVIEWED FOR CODE COMPLIANCE APPROVED APR 12 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 1 1 2018 PERMIT CENTER 2 a. O O N <n 0)0Q mW� Z Oj C CO Q 0 Amo e 2 0 0 L Q •c _c p .a' N 0 �N j0 > CO O W N Z ti.)00m 0 tf) r Residence No. ReNsbnAesue Date 01 As—Butt 02/23 02 Proposed 03/05 1 E000 03/05/18 1/2•=1'-0 P2 J March 15, 2018 City of Tukwila Department of Community Development NICHOLAS COMEAUX 14508 NE 200 ST - SUITE 200 BELLEVUE, WA 98007 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D18-0063 COMEAUX RESIDENCE - 13544 35 AVE S Dear NICHOLAS COMEAUX, 0 Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Alien Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. "New revised" plan sheets shall be the same size sheets as those previously submitted.) "STAMP AND SIGNATURES" (If applicable) For Engineers: "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient (WAC 196-23-010 & 196-23-020). Architects: "date" only not required (WAC 308-12-081). (BUILDING REVIEW NOTES) 1. Please provide an elevation cross section of the second -floor bathroom that shows ceiling height and all wall height dimensions. The height above the bottom of a shower or tub at the shower head shall be a minimum of 6 feet 8 inches, and no less than 30 inches each way at the shower head. (IRC R305.1) 2. Habitable rooms shall have a floor area of not less than 70 square feet. Habitable rooms shall be not less than 7 feet in any horizontal dimension. Portions of a room with a sloping ceiling measuring less than 5 feet or a furred ceiling measuring less than 7 feet from the finished floor to the finished ceiling shall not be considered as contributing to the minimum required habitable area for that room. Show the room areas in the loft qualify as habitable rooms. (IRC R304.1, R304.2 & R304.3) 3. Show the bedroom window complies with requirements for egress window with clear opening dimensions and distance from fmish floor. All other bedroom windows shall also meet egress requirements per code. (IRC R310.2.1 & R310.2.2) 4. Show dimensions between fixtures, specifically the toilet to show clearance is 15 inches off center each side. The space in front of a lavatory sink shall be no less than 24 inches. (IRC R307.1 & UPC 402.5) 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 5. Where the wall is to be removed on the main floor, verify if that is a bearing wall. Specify header and header size. Specify post type and sizes. Show how all are mechanically fastened. Show how the post columns are supported below the floor. Any roof or floor loads shall be supported by walls, headers or beams supported by columns, intermittent solid blocking; transferring all loads to a foundation or ground support column and footing. Please clarify and show basement or crawl space where the foundation or pad is located and type of supporting members. 6. The bathrooms and kitchen show smoke and CO. detector alarms. Smoke alarms shall be installed in bedrooms or sleeping areas. Smoke and CO alarms shall be outside each separate sleeping area in the immediate vicinity of the bedrooms, and not less than 3 feet horizontally from the door or opening of a bathroom. Ionization smoke alarms shall not be installed less than 20 feet horizontally from a permanently installed cooking appliance. Revise plan where alarm shall be placed per code. (IRC R314 & R315) 7. Show a ventilation exhaust fan located in the laundry room. Also specify the door size. 8. I noticed the refrigerator shall be located partially in front of the window. This is only an observation, not a code violation. It is more of a design observation for your attention. 9. Main floor bathroom existing floor plan has note, "Window that I could not reach". The new floor plan shows the window at that location of the tub on the main floor and loft. Glazing in walls facing tubs where the bottom edge of the glazing is less than 60 inches measured from the bottom of the tub and less than 60 inches horizontally in straight line from the water's edge, shall be safety glazing. Show those windows within those parameters to be installed with safety glazing. (IRC R308.4.5) 10. Some of the fonts are very small to read, mostly the opening sizes. The top floor bathroom wall has an opening where the size is hidden behind the lines. Plans shall be clear and legible. Please increase font size a little to be legible. 11. It appears the upper floor has some small doors showing on each side assuming attic access doors. Please clarify and identify attic space and also show the outside walls of the house. Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. Sincerely, 7Dt0 36,,X Bill Rambo Permit Technician File No. D18-0063 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 CPERMIT COORD COPY p PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0063 DATE: 04/11/18 PROJECT NAME: COMEAUX RESIDENCE SITE ADDRESS: 13544 35TH AVE S Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: MAIC Building Division 111 Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: 04/12/18 Structural Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05/10/18 Approved ❑ Approved with Conditions Corrections Required ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: 1/01 5 O ' 1 koms REVIEWER'S INITIALS: DATE: PON*`i CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 9ERMITCOORDCOPY � PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0063 DATE: 03/08/18 PROJECT NAME: COMEAUX RESIDENCE SITE ADDRESS: 13544 35 AVE S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: , - Cor %—'111 Building Division 5 art AV4 9-18 Public Works AtA lAk `� )c$ ij�313-Ie Fire Prevention Planning Division Structural ❑ Permit Coordinator al PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 03/13/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews DUE DATE: 04/10/18 Approved with Conditions n Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only 2 r CORRECTION LETTER MAILED: v-- 1 Departments issued corrections: Bldg Fire ❑ Ping 0 PW ❑ Staff Initials: 12/18/2013 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: I /("/' Plan Check/Permit Number: l/ v U 3 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: a r^ e 'd c Project Address: (3 S 141/ 3 S s Contact Person: Nt 0-A4 ✓ e Summary of Revision: 4-41.d e "ore Ir( V-4 U 4-k;L Sect,/ (.et. wry £v fC scJ e1. k Phone Number: q LS - cl S ?- `1 5-1/ a ✓per sr 4tooy s j 1--41,/ G s Gctl i ^ fG/-1(-EoY.✓c1 -✓^ W�. wede,✓X , 0e-4-. �✓ ,crt ••••• . frL tikes/ % •Gh/ ✓ / A b 9 r✓1.(,/ t . Ce'S/ ��evftr. a� v 1/cy ' Cc. •At RECEIVED CITY OF TUKWILA MWC I/1 i moi✓- c �A a -J 11.k 41 s, e-� Ih/"J. APR 1 1 2018 PERMIT CENTER Sheet Number(s): P I P 40 "Cloud" or highlight all areas of revision inclu Received at the City of Tukwila Permit Center by: 151 Entered in TRAKiT on W:\Pcmit Centa1Tempbries\Fomu\Revision submittal Form.doc CITY OF TUKWILA Department of Community Development 630o Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-367o FAX (206) 431-3665 E-mail: tukplanci.tukwila.wa.us Permit Center/Building Division 206 431-367o Public Works Department 206 433-0179 Planning Division 206 431-367o AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION PERMIT NO:pl /W0"/ STATE OF WASHINGTON) ) ss. COUNTY OF KING IV,` c),16 tc 3 CGrh e USX , states as follows: [please print name] 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number /1 , and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. Owner Owner's Agent* Signed and sworn to before me this I day of I 1 rgtioit-AQ NOTARY PUBLIC in a d for th State of Washington Residing at'r ■ , C• xlty Name as commissioned: / / tk My commission expires: I �� 411 18.27.090 Exemptions. The registration provisions of this 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile/manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW who shall warranty service and repairs under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed chapter do not apply to: by a registered contractor; 11. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile/manufactured home dealer or manufacturer who subcontracts the installation, set-up, or repair work to actively registered contractors. This exemption only applies to the installation, set-up, or repair of the mobile/manufactured homes that were manufactured or sold by the mobile/manufactured home dealer or manufacturer; 18. An entity who holds a valid electrical contractor's license under chapter 19.28 RCW that employs a certified journeyman electrician, a certified residential specialty electrician, or an electrical trainee meeting the requirements of chapter 19.28 RCW toperform.plumbing work that is incidentally, directly, and immediately appropriate to the like -in-kind replacement of a household appliance or other small household utilization equipment that requires limited electric power andtlimited waste and/or water connections. An electrical trainee must be supervised by a certified electrician while performing plumbing work. ' Per Washington State Department of Labor and Industries lessee has been interpreted to be equivalent to owner for purposes of exemptions.