HomeMy WebLinkAboutPermit D18-0063 - COMEAUX RESIDENCE - BATHROOM, OPEN LOFT / KITCHEN AND CLOSE UTILITY ROOMCOMEAUX RESIDENCE
13544 35 AVE S
D18-0063
Parcel No:
Address:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.eov
8864000045
13544 35TH AVE S
Project Name: COMEAUX RESIDENCE
DEVELOPMENT PERMIT
Permit Number: D18-0063
Issue Date:
Permit Expires On:
4/13/2018
10/10/2018
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
License No:
OXENRIDER WESLEYJ
13544 35TH AVE 5 , SEATTLE, WA,
98168
NICHOLAS COMEAUX
14508 NE 20 ST - SUITE 200 ,
BELLEVUE, WA, 98007
OWNER AFFIDAVIT- NICHOLAS
COMEAUX
Lender:
Name: JMD INVESTMENTS LLC
Address: 14508 NE 200 ST - SUITE 200 ,
BELLEVUE, WA, 98007
Phone: (425) 457-4549
Phone:
Expiration Date:
DESCRIPTION OF WORK:
COSMETIC REMODEL, ADD BATHROOM UPSTAIRS AND OPEN UP LOFT. OPEN UP KITCHEN AND CLOSE OFF UTILITY
ROOM.
Project Valuation: $32,000.00
Type of Fire Protection: Sprinklers: NO
Fire Alarm: NO
Type of Construction: VB
Electrical Service Provided by: TUKWILA
Fees Collected: $1,231.35
Occupancy per IBC: R-3
Water District: 125
Sewer District: VALLEY VIEW
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
2015
2015
2015
2015
2015
National Electrical Code:
WA Cities Electrical Code:
WAC 296-468:
WA State Energy Code:
2017
2017
2017
2015
Public Works Activities:
Channelization/Striping:
Curb Cut/Access/Sidewalk:
Fire Loop Hydrant:
Flood Control Zone:
Hauling/Oversize Load:
Land Altering:
Landscape Irrigation:
Sanitary Side Sewer:
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter:
Volumes: Cut: 0 Fill: 0
Number: 0
No
Permit Center Authorized Signature: Pikibl Vii)11/1('
J
Date: 4
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature:
Print Name: \\I:(A.A r
Date: (1A -1K
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***BUILDING PERMIT CONDITIONS***
2: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
3: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
4: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
5: There shall be no occupancy of a building until final inspection has been completed and approved by
Tukwila building inspector. No exception.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector based
on satisfactory completion of this requirement.
7: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy
can be obtained at City Hall in the office of the City Clerk.
8: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion.
Strapping shall be at points within the upper one-third and lower one-third of the water heater's vertical
dimension. A minimum distance of 4 -inches shall be maintained above the controls with the strapping.
9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the City
of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
12: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center (206/431-3670).
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1700 BUILDING FINAL**
0409 FRAMING
0606 GLAZING
0603 ROOF/CEILING INSUL
0601 WALL INSULATION
BUILDING PERMIT INFORMATIOr 1O6-431-3670
Valuation of Project (contractor's bid price): $ 3 2---,0&0 Existing Building Valuation: $
Describe the scope of work (please provide detailed information):
llS,�,�J; e-.���1 ( ‘1d1 L14 (1-40 4- orb. vr 6)-/Je-�
•�Gv vim` I
(,sc ,k -f,4
/
Will there be new rack storage? ❑ Yes
yr
rvh D
.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? 0 Yes 0 No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
0 Sprinklers 0 Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No
If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx
Revised: August 2011
bh
Page 2 of 4
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
1' Floor
2nd Floor
7-6\ 4
3rd Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? 0 Yes 0 No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
0 Sprinklers 0 Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No
If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx
Revised: August 2011
bh
Page 2 of 4
PUBLIC WORKS PERMITINFOIiATION — 206-433-0179
Scope of Work (please provide detailed information):
Call before you Dig: 811
Please refer to Public Works Bulletin #1 for fees and estimate sheet.
Water District
❑ ...Tukwila ❑ ...Water District #125
❑ ...Water Availability Provided
Sewer District
❑ ...Tukwila
❑ ...Sewer Use Certificate
0 .. Highline
❑ ...Valley View ❑ .. Renton
0... Sewer Availability Provided
0 .. Renton
❑ .. Seattle
Septic System:
0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department.
Submitted with Application (mark boxes which apply):
❑ ...Civil Plans (Maximum Paper Size — 22" x 34")
❑ ...Technical Information Report (Storm Drainage)
0 ...Bond 0 .. Insurance ❑ .. Easement(s)
Proposed Activities (mark boxes that apply):
❑ ...Right-of-way Use - Nonprofit for less than 72 hours
❑ ...Right-of-way Use - No Disturbance
❑ ...Construction/Excavation/Fill - Right-of-way 0
Non Right-of-way ❑
0 ...Total Cut
❑ ...Total Fill
cubic yards
cubic yards
❑ ...Sanitary Side Sewer
❑ ...Cap or Remove Utilities
0 ...Frontage Improvements
❑ ...Traffic Control
❑ ...Backflow Prevention - Fire Protection
Irrigation
Domestic Water
❑ .. Geotechnical Report
0 .. Maintenance Agreement(s)
❑ ...Traffic Impact Analysis
❑ ... Hold Harmless — (SAO)
❑ ...Hold Harmless — (ROW)
❑ .. Right-of-way Use - Profit for less than 72 hours
❑ .. Right-of-way Use — Potential Disturbance
❑ .. Work in Flood Zone
❑ .. Storm Drainage
❑ .. Abandon Septic Tank
0 .. Curb Cut
❑ .. Pavement Cut
❑ .. Looped Fire Line
0 ...Permanent Water Meter Size...
❑ ...Temporary Water Meter Size ..
❑ ...Water Only Meter Size
❑ ...Sewer Main Extension Public 0
❑ ...Water Main Extension Public 0
91
WO #
WO #
WO #
Private 0
Private 0
❑ .. Grease Interceptor
❑ .. Channelization
❑ .. Trench Excavation
❑ .. Utility Undergrounding
❑ ...Deduct Water Meter Size
FINANCE INFORMATION
Fire Line Size at Property Line Number of Public Fire Hydrant(s)
0 ...Water
❑ ...Sewer ❑ ...Sewage Treatment
Monthly Service Billing to:
Name: Day Telephone:
Mailing Address:
Water Meter Refund/Billing:
Name:
Mailing Address:
City
State Zip
Day Telephone:
City
State Zip
Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx
Revised: August 2011
bh
Page 3 of 4
PERMIT APPLICATION NOTES – �+wr
Auk
Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review – Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWN R OR AUTH
Signature:
Print Name: N ol-wil <s C G € a v�
Mailing Address: 14 8 N 54 1j-2
H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-11.docx
Revised: August 2011
bh
Date: ��-1 V
Day Telephone: NI? °15'1- —YSY
YG 1l evv.e
City
State Zip
Page 4 of 4
DESCRIPTIONS
PermitTRAK
Cash Register Receipt
City of Tukwila
ACCOUNT
QUANTITY
PAID
1,231.35
D18-0063 Address: 13544 35TH AVE S Apn: 8864000045
.231.35
DEVELOPMENT
$1,195.27
PERMIT FEE
R000.322.100.00.00
0.00
$721.68
PLAN CHECK FEE
R000.345.830.00.00
0.00
$469.09
WASHINGTON STATE SURCHARGE
B640.237.114
0.00
$4.50
TECHNOLOGY FEE
$36.08
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R13962
R000.322.900.04.00
0.00
$36.08
$1,231.35
Date Paid: Thursday, March 08, 2018
Paid By: JMD INVESTMENTS LLC
Pay Method: CHECK 1503
Printed: Thursday, March 08, 2018 2:22 PM
1 of 1
I?WSYSTEMS
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
�I c063
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project:
tea, E .)( Af1-1
Type of Inspecti n:
1/31114.1Z 641 --
Address:
433-1/4 3511 s
Date Called:
Special Instructions:
Date Wanted:_
/ •//'/k
p.m.
Requester:
Phone No:
Nri6
COMMENTS: c g�lc_.o ,✓h. ���
pproved per applicable codes. LJ Corrections required prior to approval.
Inspector:
Date:
d—M 4 —t 1
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
_0b3
Project: t n
COMeAtAX ,c,Vr
T e of I` sp
Abu.,1C
tion: r
/hL
Address:
i15-9/1 35*-vcsS
Date Called:
Special Instructions:
Date Wanted:
Req sten:
Phone
9z5 577- 9/2S
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
A_ .ccit.ewuk
Inspector: :_-c:2
Date// _ ze/sr.„,-
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project:
CDrn em G
Typef Inspection:
�14 74JSuL.'h,bY)
Address:
/35/PI c_35* Ave. S,
Date Called:
Special Instructions:
Date Wanted: a.m.
7-tz 2.01fS p.m.
Requester:
IV SCK
Phone No:
II —1/57-
1-/51. 1.9
ElApproved per applicable codes. Corrections required prior to approval.
COMMENTS:
Inspector:760
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
PPjeect: ®�
7��
:
Type f Inspection:
i�nprz
ldA3c_�d�%rey6;I
��jS:
Date
Special Instructions:
1 nV-.0A/`
Date Wanted:
a.m. `�� a.m.
p.m.
l
Requester:
Phone No:
Approved per applicable codes.
Corrections required prior to approval.
C
OMMENT
s*P4CSS
OkAivv`104CS •
a -e S LACKI-Zg
ckeitile_tvLsprAo\lt
Inspector:
0.,7 rya'
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
Di 3 -0663
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project:
(:pMLf Ct,c 9(
Type Inspection:
9*"✓ 4M I egi-
Address:Date
Trfi 35'1/y 35 ,
Called:
Special Instructions:
-rat/11104/
Date Wanted:�p�
7-3—
m.
/m.
Requester:
Phone No:
j X� Approved per applicable codes.
COMMENT • _
E] Corrections required prior to approval.
"119
oma.
erd (7‘.(a otiska,
-TV ;-r" AL5 Q-C-coki
inspector:
Date:
�J
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project:
tam1 il,>o
Type of Inspection:
Erb l0
Address: M
!3Sµ4 35 &IL Si
Date Called:
Special Instructions:
O ck. _
Date Wanted:7 —2_
a,m
p.m.
Requester:
Phone No:
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
ece
it th_5 / M 4i aut.."(
riK b011 -v)41 s �
Date:
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
DI -&Z3
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project: mom^ , 'x
Type of Inspection:
frrIfil fey
Address:
`3syy 35
�.
Date Called:
�
Special Instructions:
Dat Wanted: _ �q
(0 z8 z.g/
\d•-�
p.m.
Requester:
Phone No:
CApproved per applicable codes.
COMMENTS:
Corrections required prior to approval.
04-10ack ee Aouso 441 rte'
(F)
€ 4e
O
Z,) c4 -Orn 1J 5 9 _
e"l
a,LL beam/ dooe S
cod tS/OV, 0-kveha
(v, A x bD//M L ad-S?49-r K,
Inspecto
Date:/
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
SEPARATE PERMIT
REQUIRED FOR:
GechaniCW
electrical
[dumbing
s Piping
G iy of Tukwila
, 12110 DIVISION
5 1"
7'-113"
Height 4' 5"
WSH 2'4"
11'0}"
6'-11}'
1'-7'
1
2'-53"
/ 3' 8}" /
10. 23"
FILE C
Permit No.
5-43"
3' 1
—14
1
714— 2' 5}"
8' 5
'-107"
4'-11" T
Height 6 1/2"
WSH6'11/2"
0
3'-33"
1-11"
-- 2' 57' -
2'-4"
2'-2=
10 27'
13' 43"
1'-4"'7 Height 3' 5" 4' 7i' —T
WSH 3'31/2"
Height 4' 5'
WSH 2'4"
'f2'5?—
2' 9" —�
7' 6?
2'-11?
f-2'-13"-71 *--3'11"
A' 2' 6„ —71'
3' 10?
2' 4
2'-37"
3' 1? --74
101/7 runner
1
2%6"
4 87 —74
Plan review approval Is subject to a omissions.
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Feld Copy and conditions is acknowledged
Date: _j/34' s-
City of Tukwila
BUILDING DIVISION
Height 4'51/2" 4' 97'
W51-1 2'3"
11'-117"
0
Height 1' 6 1/4"
WSH 3' 7"
5' 27'
14'53'
r
6' 5?"
6' 117"
1'-77"
13' 73"
9,-2}"
4' 33" 7=
17' 21"
Height 4' 4"
W511 2' 31/2"
2'-33'
1st Floor As—Built
1/4" = 1-0"
REVISIONS
No changes shall he made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: €ieviskons will require a new plan submittal
and may include additional plan review fees.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
APR 12 2018
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
APR 1 1 2018
PERMIT CENTER
CORRECTION
N
LTR#
0
0
1n
cn
Q
: W
CO Z 8j
O 010
000)
0
0
C
v� N
00.0
c >00
0 W (I)0)
Z
NN
00M
I 0
9')
r
Residence
tn�
01
• > 0
Q�
O 00
0 (7 to
min
�
fA
Q
No.
Revision/Issus
Date
01
As—BuAt
02/23
•
000
Coto
02/23/18
9' 8+"
12' 1}"
8,_10+"
3'-1
6' 2"
8' 6}"
Roof Line on Ceiling
11' 9'
f—- 5, 2+"
6'
5' 7+"
2' 4"
3' O„
-FA
12' 1}"
1,_10+"
2
4'-7+"
2'-1}"
1'-2+"
Demo Walls
5' 5+"
2.4
3'-2+"
6,_8+"
f— 3,_4" —f
•
13' 5+"
2nd Floor As—Built
1/4" = 1'-0"
RECEIVED
CITY OF TUKWILA
REVIEWED FOR
CODE COMPLIANCp
APPROVED
APR 12 2018
City of Tukwila
BUILDING DIVISION
APR 1 1 2018
RMiTa`7 i .. .1 E
fR
fi
2
O
O
N
qkQ
C
N �o
c >00
0Z Cr)
0)
N 00 m
= O
r
Residence
cnCn
> 0
vat
0 0D
v LD
M 3 0,
m 4-
cn are)
No.
Revision/18804
Date
01
As—Butt
02/23
1
000
Dot*
02/23/18
Sod
P2
9
7'-11*"
Safety Glazed
Height 3' 5"
WSH 4'
Height 4' 5"
y` 5'-1" / WSH 2' 4"
4 --
Height 3' 5"
WSH 3' 3 1/2"
13'-4*"
1'-4" / f-- 4'-7*"
6'-11}"
11'-0*"
EN 1
-1,--
121
f- 3'83"-4
3'-1�a" —/- 2,44,E
1'-11" 1
-1k---
2'-5i" —
Bed Room
0
'-11"
8'-5
1'-10*"
\A,
7'-5*"
2'-4"
or
3'-3*" —�
5'-41r"
10'-2*"
2'-4*"
e 3
0
0
Bath Room
6-8*"
Bed Room
CD
Al-- 2'-5}" —714
-2
Height 4' 5" t_
WSH 2'4" 2'-Oa"—�
f f---- 5'-2*"
00•00
2'-1*"
5'-0* '
3'-10*i'
'-5
10'-2*"
2'-3*"
/ _ l 3'-111" ---/
7'-9*"
10 uz• runner
2'-6"
4'-8
/-- 4'-9*" —�
11-11*"
Height 4' 5 1/2"
WSH 2'3"
1,9
3'
Kitchen
New Walls
3'-11 " --714
-+
3'-4„
►�
•
•
•4
•
•
•
•
•
•
1'-9*"
om
7'-5$"
14' 5i
Living Room
f-- 5'-2b"
6'-5*"
l' -7i"
6'-11*"
2'-9*"
X
N
it) �
13'-7's"
9'-2*"
4.-3r" —�
1 7'-2*"
Height 4' 4"
WSH 2' 3 1/2"
2'-3*"
1st Floor Proposed
1/4" = 1'-0"
RECEIVED
CITY OF TUKWILA
REVIEWEDFOR
CODE COMPLIA
APPROVED
APR 12 2018
City of Tukwila
BUILDING DIVISION
PR 1 1 2018
IT CENTER
0
0
CV
to
tno`
y
Cr)oQ
CO W
z0
C t10 jr
o 0
a
Gmco
0
0
CV
v
o
LQ
00 >0
w sT
Z CD co U.1
= 0
In
•
No.
Revision/Issue
Dote
01
As—Butt
02/23
02
Proposed
03/05
Dges
P1J
Impot
000
03/05/18
Ude
, /4.•=1.-0
1
8'-
3'-13"
3'-3i"
2'-5**"
9'-83"
12'-1}"
Bed Room
Roof Line on Ceiling
8'-6*"
1'-103"
pe-- 5'-2i"
Attic
2,�,�
3 03
-14
12'-1}"
Attic
1'-7}
12'-10"
%`:` ale
We ,"t� Y'
Loft Room
New Walls
7' 83"
2'-3$"
1'
•&• •A♦ •&.'&:••�
5'-5}"
4' 6"
1'-9"
2,-4"
-23
•
4'
4
Bath Room
0
111
0
2'-
1'-03"
V V WWWWW VVIP VVVVV eV
•
9'-4*"
2nd Floor Proposed
1/4" = 1)-0)'
7' -
N�
0L
7 V%
1'-6*"
._
1REVIEWED FOR
C'ODE COMPLIANCE
APPROVED
APR 12 2018
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TIJKWILA
APR 1 1 2018
PERMIT CENTER
0
0
CV
03 4k
07
-c
(5 Q
: W
m Z
O)
o
O
CO 00)
0
0
N
L �Q
c-3
p 4-O,
N > 00
oW Np)
Za)
0 00 m
s0
in
Residence
No.
Revision/Issue
Date
01
As—Butt
02/23
02
Proposed
03/05
wop
000
0
03/05/18
lode
�1 /4'-1'-0
1
P 2)
J
New Walls
(TYP.)
x( (
RifsfP
ert
y
e (41
170 #"
ioIo
2x8 Rafters
Orig. Walls
(TYP.)
Unused Space
CA)
Loft Cross—Section
1 /2" = V-0"
2x8 Joists
REVIEWED FOR
CODE COMPLIANCE
APPROVED
APR 12 2018
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
APR 1 1 2018
PERMIT CENTER
2
a.
O
O
N
<n
0)0Q
mW�
Z Oj
C
CO Q 0
Amo
e
2
0
0
L Q
•c _c
p .a' N
0
�N j0
> CO
O W N
Z
ti.)00m
0
tf)
r
Residence
No.
ReNsbnAesue
Date
01
As—Butt
02/23
02
Proposed
03/05
1
E000
03/05/18
1/2•=1'-0
P2
J
March 15, 2018
City of Tukwila
Department of Community Development
NICHOLAS COMEAUX
14508 NE 200 ST - SUITE 200
BELLEVUE, WA 98007
RE: Correction Letter # 1
DEVELOPMENT Permit Application Number D18-0063
COMEAUX RESIDENCE - 13544 35 AVE S
Dear NICHOLAS COMEAUX,
0
Allan Ekberg, Mayor
Jack Pace, Director
This letter is to inform you of corrections that must be addressed before your development permit can be approved. All
correction requests from each department must be addressed at the same time and reflected on your drawings. I have
enclosed comments from the following departments:
BUILDING DEPARTMENT: Alien Johannessen at 206-433-7163 if you have questions regarding these comments.
• (GENERAL INFORMATION NOTE)
PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. "New
revised" plan sheets shall be the same size sheets as those previously submitted.)
"STAMP AND SIGNATURES" (If applicable) For Engineers: "Every page of a plan set must contain the
seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the
work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall
contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a
licensee are a portion of a bound specification document that contains specifications other than that of an
engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents
for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to
be stamped and signed; Front page only will be sufficient (WAC 196-23-010 & 196-23-020). Architects: "date"
only not required (WAC 308-12-081).
(BUILDING REVIEW NOTES)
1. Please provide an elevation cross section of the second -floor bathroom that shows ceiling height and all wall
height dimensions. The height above the bottom of a shower or tub at the shower head shall be a minimum of 6 feet
8 inches, and no less than 30 inches each way at the shower head. (IRC R305.1)
2. Habitable rooms shall have a floor area of not less than 70 square feet. Habitable rooms shall be not less than 7
feet in any horizontal dimension. Portions of a room with a sloping ceiling measuring less than 5 feet or a furred
ceiling measuring less than 7 feet from the finished floor to the finished ceiling shall not be considered as
contributing to the minimum required habitable area for that room. Show the room areas in the loft qualify as
habitable rooms. (IRC R304.1, R304.2 & R304.3)
3. Show the bedroom window complies with requirements for egress window with clear opening dimensions and
distance from fmish floor. All other bedroom windows shall also meet egress requirements per code. (IRC
R310.2.1 & R310.2.2)
4. Show dimensions between fixtures, specifically the toilet to show clearance is 15 inches off center each side. The
space in front of a lavatory sink shall be no less than 24 inches. (IRC R307.1 & UPC 402.5)
6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
5. Where the wall is to be removed on the main floor, verify if that is a bearing wall. Specify header and header
size. Specify post type and sizes. Show how all are mechanically fastened. Show how the post columns are
supported below the floor. Any roof or floor loads shall be supported by walls, headers or beams supported by
columns, intermittent solid blocking; transferring all loads to a foundation or ground support column and footing.
Please clarify and show basement or crawl space where the foundation or pad is located and type of supporting
members.
6. The bathrooms and kitchen show smoke and CO. detector alarms. Smoke alarms shall be installed in bedrooms
or sleeping areas. Smoke and CO alarms shall be outside each separate sleeping area in the immediate vicinity of
the bedrooms, and not less than 3 feet horizontally from the door or opening of a bathroom. Ionization smoke
alarms shall not be installed less than 20 feet horizontally from a permanently installed cooking appliance. Revise
plan where alarm shall be placed per code. (IRC R314 & R315)
7. Show a ventilation exhaust fan located in the laundry room. Also specify the door size.
8. I noticed the refrigerator shall be located partially in front of the window. This is only an observation, not a code
violation. It is more of a design observation for your attention.
9. Main floor bathroom existing floor plan has note, "Window that I could not reach". The new floor plan shows
the window at that location of the tub on the main floor and loft. Glazing in walls facing tubs where the bottom
edge of the glazing is less than 60 inches measured from the bottom of the tub and less than 60 inches horizontally
in straight line from the water's edge, shall be safety glazing. Show those windows within those parameters to be
installed with safety glazing. (IRC R308.4.5)
10. Some of the fonts are very small to read, mostly the opening sizes. The top floor bathroom wall has an opening
where the size is hidden behind the lines. Plans shall be clear and legible. Please increase font size a little to be
legible.
11. It appears the upper floor has some small doors showing on each side assuming attic access doors. Please
clarify and identify attic space and also show the outside walls of the house.
Note: Contingent on response to these corrections, further plan review may request for additional corrections.
Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other
documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be
resubmitted with the appropriate revision block.
In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have
enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail
or by a messenger service.
Sincerely,
7Dt0 36,,X
Bill Rambo
Permit Technician
File No. D18-0063
6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
CPERMIT COORD COPY p
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: D18-0063 DATE: 04/11/18
PROJECT NAME: COMEAUX RESIDENCE
SITE ADDRESS: 13544 35TH AVE S
Original Plan Submittal Revision # before Permit Issued
X Response to Correction Letter # 1 Revision # after Permit Issued
DEPARTMENTS:
MAIC
Building Division 111
Public Works
Fire Prevention
Structural
Planning Division
❑ Permit Coordinator
PRELIMINARY REVIEW:
Not Applicable ❑
(no approval/review required)
REVIEWER'S INITIALS:
DATE: 04/12/18
Structural Review Required
DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 05/10/18
Approved ❑ Approved with Conditions
Corrections Required ❑ Denied
(corrections entered in Reviews) (ie: Zoning Issues)
Notation: 1/01 5 O ' 1
koms
REVIEWER'S INITIALS:
DATE:
PON*`i
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
12/18/2013
9ERMITCOORDCOPY �
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: D18-0063 DATE: 03/08/18
PROJECT NAME: COMEAUX RESIDENCE
SITE ADDRESS: 13544 35 AVE S
X Original Plan Submittal
Response to Correction Letter #
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
, - Cor %—'111
Building Division 5
art AV4 9-18
Public Works
AtA lAk `� )c$ ij�313-Ie
Fire Prevention Planning Division
Structural
❑ Permit Coordinator al
PRELIMINARY REVIEW:
Not Applicable ❑
(no approval/review required)
DATE: 03/13/18
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved
Corrections Required
(corrections entered in Reviews
DUE DATE: 04/10/18
Approved with Conditions n
Denied
(ie: Zoning Issues)
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only 2 r
CORRECTION LETTER MAILED: v-- 1
Departments issued corrections: Bldg Fire ❑ Ping 0 PW ❑
Staff Initials:
12/18/2013
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Web site: http://www.TukwilaWA.gov
Revision submittals must be submitted in person at the Permit Center.
Revisions will not be accepted through the mail, fax, etc.
Date: I /("/' Plan Check/Permit Number: l/ v U 3
❑ Response to Incomplete Letter #
❑ Response to Correction Letter # 1
❑ Revision # after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
❑ Deferred Submittal #
Project Name: a r^ e 'd c
Project Address: (3 S 141/ 3 S s
Contact Person: Nt 0-A4 ✓ e
Summary of Revision:
4-41.d
e "ore Ir(
V-4 U
4-k;L Sect,/
(.et. wry
£v fC scJ
e1.
k
Phone Number: q LS - cl S ?- `1 5-1/
a ✓per sr 4tooy s j 1--41,/ G s Gctl i ^ fG/-1(-EoY.✓c1 -✓^ W�.
wede,✓X , 0e-4-. �✓
,crt
••••• . frL tikes/ % •Gh/ ✓ / A b
9 r✓1.(,/
t . Ce'S/ ��evftr. a� v 1/cy '
Cc. •At
RECEIVED
CITY OF TUKWILA
MWC I/1
i moi✓- c �A a -J
11.k 41 s,
e-�
Ih/"J.
APR 1 1 2018
PERMIT CENTER
Sheet Number(s): P I P 40
"Cloud" or highlight all areas of revision inclu
Received at the City of Tukwila Permit Center by:
151 Entered in TRAKiT on
W:\Pcmit Centa1Tempbries\Fomu\Revision submittal Form.doc
CITY OF TUKWILA
Department of Community Development
630o Southcenter Boulevard, Tukwila, WA 98188
Telephone: (206) 431-367o FAX (206) 431-3665
E-mail: tukplanci.tukwila.wa.us
Permit Center/Building Division
206 431-367o
Public Works Department
206 433-0179
Planning Division
206 431-367o
AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION
PERMIT NO:pl /W0"/
STATE OF WASHINGTON)
) ss.
COUNTY OF KING
IV,` c),16 tc 3 CGrh e USX , states as follows:
[please print name]
1. I have made application for a permit from the City of Tukwila, Washington.
2. I understand that state law requires that all building construction contractors be registered with the
State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the
Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have
read or am familiar with RCW 18.27.090.
3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the
City of Tukwila must verify either that the contractor is registered by the State of Washington, or that
one of the exemptions stated under RCW 18.27.090 applies.
4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I
hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090,
I consider the work authorized under this permit to be exempt under number /1 , and will therefore
not be performed by a registered contractor.
5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to
persons making electrical installations on their own property or to regularly employed employees
working on the premises of their employer. The proposed electrical work is not for the construction
of a new building for rent, sale or lease.
I understand that I may be waiving certain rights that I might otherwise have under state law in any decision
to engage an unregistered contractor to perform construction work.
Owner
Owner's Agent*
Signed and sworn to before me this
I day of I 1
rgtioit-AQ
NOTARY PUBLIC in a d for th
State of Washington
Residing at'r ■ , C• xlty
Name as commissioned: / / tk
My commission expires: I �� 411
18.27.090 Exemptions. The registration provisions of this
1. An authorized representative of the United States
government, the state of Washington, or any incorporated
city, town, county, township, irrigation district, reclamation
district, or other municipal or political corporation or
subdivision of this state;
2. Officers of a court when they are acting within the scope
of their office;
3. Public utilities operating under the regulations of the
utilities and transportation commission in construction,
maintenance, or development work incidental to their own
business;
4. Any construction, repair, or operation incidental to the
discovering or producing of petroleum or gas, or the
drilling, testing, abandoning, or other operation of any
petroleum or gas well or any surface or underground mine
or mineral deposit when performed by an owner or lessee;
5. The sale of any finished products, materials, or articles of
merchandise that are not fabricated into and do not become
a part of a structure under the common law of fixtures;
6. Any construction, alteration, improvement, or repair of
personal property performed by the registered or legal
owner, or by a mobile/manufactured home retail dealer or
manufacturer licensed under chapter 46.70 RCW who shall
warranty service and repairs under chapter 46.70 RCW;
7. Any construction, alteration, improvement, or repair
carried on within the limits and boundaries of any site or
reservation under the legal jurisdiction of the federal
government;
8. Any person who only furnished materials, supplies, or
equipment without fabricating them into, or consuming
them in the performance of, the work of the contractor;
9. Any work or operation on one undertaking or project by
one or more contracts, the aggregate contract price of
which for labor and materials and all other items is less
than five hundred dollars, such work or operations being
considered as of a casual, minor, or inconsequential nature.
The exemption prescribed in this subsection does not apply
in any instance wherein the work or construction is only a
part of a larger or major operation, whether undertaken by
the same or a different contractor, or in which a division of
the operation is made into contracts of amounts less than
five hundred dollars for the purpose of evasion of this
chapter or otherwise. The exemption prescribed in this
subsection does not apply to a person who advertises or
puts out any sign or card or other device which might
indicate to the public that he or she is a contractor, or that
he or she is qualified to engage in the business of
contractor;
10. Any construction or operation incidental to the
construction and repair of irrigation and drainage ditches
of regularly constituted irrigation districts or reclamation
districts; or to farming, dairying, agriculture, viticulture,
horticulture, or stock or poultry raising; or to clearing or
other work upon land in rural districts for fire prevention
purposes; except when any of the above work is performed
chapter do not apply to:
by a registered contractor;
11. An owner* who contracts for a project with a registered
contractor, except that this exemption shall not deprive the
owner of the protections of this chapter against registered
and unregistered contractors. The exemption prescribed in
this subsection does not apply to a person who performs
the activities of a contractor for the purpose of leasing or
selling improved property he or she has owned for less than
twelve months;
12.* Any person working on his or her own property,
whether occupied by him or her or not, and any person
working on his or her personal residence, whether owned
by him or her or not but this exemption shall not apply to
any person who performs the activities of a contractor on
his or her own property for the purpose of selling,
demolishing, or leasing the property;
13. An owner* who performs maintenance, repair, and
alteration work in or upon his or her own properties, or
who uses his or her own employees to do such work;
14. A licensed architect or civil or professional engineer
acting solely in his or her professional capacity, an
electrician certified under the laws of the state of
Washington, or a plumber certified under the laws of the
state of Washington or licensed by a political subdivision of
the state of Washington while operating within the
boundaries of such political subdivision. The exemption
provided in this subsection is applicable only when the
person certified is operating within the scope of his or her
certification;
15. Any person who engages in the activities herein
regulated as an employee of a registered contractor with
wages as his or her sole compensation or as an employee
with wages as his or her sole compensation;
16. Contractors on highway projects who have been
prequalified as required by RCW 47.28.070, with the
department of transportation to perform highway
construction, reconstruction, or maintenance work;
17. A mobile/manufactured home dealer or manufacturer
who subcontracts the installation, set-up, or repair work to
actively registered contractors. This exemption only applies
to the installation, set-up, or repair of the
mobile/manufactured homes that were manufactured or
sold by the mobile/manufactured home dealer or
manufacturer;
18. An entity who holds a valid electrical contractor's
license under chapter 19.28 RCW that employs a certified
journeyman electrician, a certified residential specialty
electrician, or an electrical trainee meeting the
requirements of chapter 19.28 RCW toperform.plumbing
work that is incidentally, directly, and immediately
appropriate to the like -in-kind replacement of a household
appliance or other small household utilization equipment
that requires limited electric power andtlimited waste
and/or water connections. An electrical trainee must be
supervised by a certified electrician while performing
plumbing work.
' Per Washington State Department of Labor and Industries lessee has