Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D18-0068 - PYRAMID POINT APARTMENTS / BLDG D - REROOF
PYRAMID POINT APTS BLDG D 5717 S 152 PL D18-0068 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 1157200360 5717 S 152ND PL BLDG D DEVELOPMENT PERMIT Project Name: PYRAMID POINT APTS - BLDG D Permit Number: D18-0068 Issue Date: 4/3/2018 Permit Expires On: 9/30/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: PYRAMID PROPERTY L L C P 0 BOX 40252 , BELLEVUE, WA, 98015 HERIBERTO BAHENA 1621 S 257 ST, DES MOINES, WA, 98198 ROOFTECH INC Address: 1621 S 257TH ST, DES MOINES, WA, 98198 License No: ROOFTI*882DZ Lender: Name: PYRAMID PROPERTY L L C Address: P 0 BOX 40252 , BELLEVUE, WA, 98015 Phone: (206) 851-2194 Phone: Expiration Date: 3/9/2020 DESCRIPTION OF WORK: TEAR OFF EXISTING SHINGLE ROOF. INSTALL UNDERLAYMENT. INSTALL NEW SHINGLES AND ROOF VENTS AND EDGE METAL. Project Valuation: $18,480.00 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $815.97 Occupancy per IBC: R-2 Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: 4-'1—i -'1—i I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. r PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0103 PRE-REROOF CITY OF TUKTPL..A Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. [ Q%U Project No. Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 5 W E1/4- Suite Number.)\ck D Floor: Tenant Name: 7 (Gtvu\ � PO n om PROPERTY OWNER Company Name: Zo_ r c t I �C Name: (1L Md . (ope14-7 , LLC. Contr Reg No.: Roo-F-vi,t, wism Exp Date: 2/y/Z1:) 7 Address: p Phone: (206) 8S I .. 2i ci 4 Fax: ( Use) 212 - 6. 4252 Email: V t G 6) ri-0A.1— t rvG CD ‘—^ City: Px_tleV vg, Zip: :S CONTACT PERSON — person receiving all project communication Company Name: Zo_ r c t I �C Name:p l� "" re(' o \)26 \C - .k ')5 1I City: 40‘ 1,1525 St*:A_ZLi9 , Address:, jo 2 ( S 744_ (A ....s..4_. Contr Reg No.: Roo-F-vi,t, wism Exp Date: 2/y/Z1:) City: M0 1 State: w h-- Zip: c N g Phone: (206) 8S I .. 2i ci 4 Fax: ( Use) 212 - 6. $ 4 Email: V t G 6) ri-0A.1— t rvG CD ‘—^ GENERAL CONTRACTOR INFORMATION Company Name: Zo_ r c t I �C Address: 16-2_ I S (1.5.„As# . City: 40‘ 1,1525 St*:A_ZLi9 , Phone: (.70(;),65‘._ Fax: Z-iG4 C.133b)..7_42_lo,,-.4 4_ Contr Reg No.: Roo-F-vi,t, wism Exp Date: 2/y/Z1:) Tukwila Business License No.: boo 4 i (c2, H: Applications\Forms-Applications On Line120I2 Applications'Petmit Application Revised - 2-7-12.docx Revised: February 2012 bh New Tenant: ❑ Yes ❑ .. No ARCHITECT OF RECORD Name: t (3fer6 , L I --C. (' nni A Q Address:. /) D 3cx 1-02_,. Z Company Name: Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Name: t (3fer6 , L I --C. (' nni A Q Address:. /) D 3cx 1-02_,. Z Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: t (3fer6 , L I --C. (' nni A Q Address:. /) D 3cx 1-02_,. Z City: ReAeA4,Je_ Stater Zip:clg0 Is - Page 1 of 4 BUILDING PERMIT INFORMATI( 206-431-3670 Valuation of Project (contractor's bid price): $ C3/tW3 LA) Existing Building Valuation: $ Describe the scope of work (please provide detailed information): -2hnokf e, e t s )h r D 5\•1n51 ex, t nS-kit 1 I V ir\A P -r torn , \r\k/\5\Ps ati ©o vevs4 a v e? r Is Will there be new rack storage? ❑ .... Yes ir\*1( new ❑ ..No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\ApplicationsWorms-Applications On Line\20I2 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1St Floor 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\ApplicationsWorms-Applications On Line\20I2 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Mailing Address: 0-1 S 254 -k -kit s4 Date: 03/1 2/ tot Day Telephone: C J ) 'S S — 2<<( (4 RO I'N25 P e (i 8 H:\Applications\Forms-Applications On Line \20I2 Applications\Permit Application Revised - 2-7-I2.docx Revised: February 2012 bh City State Zip Page 4 of 4 • • PUBLIC WORKS PERMIT INF(' vIATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila ❑ ...Water District #125 0 .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ .. Sewer Use Certificate ❑... Highline ❑ ....Valley View ❑...Renton ❑ ...Sewer Availability Provided 0... Renton 0... Seattle Septic System: ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ .. Civil Plans (Maximum Paper Size — 22" x 34") ❑ .. Technical Information Report (Storm Drainage) ❑... Geotechnical Report 0 .. Traffic Impact Analysis ❑ .. Bond ❑... Insurance ❑... Easement(s) 0...Maintenance Agreement(s) 0 .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): ❑ .. Right-of-way Use - Nonprofit for less than 72 hours ❑ .. Right-of-way Use - No Disturbance ❑ .. Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ❑ .. Total Cut ❑ .. Total Fill cubic yards cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities ❑ .. Frontage Improvements ❑ .. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Permanent Water Meter Size (1) ❑ .. Temporary Water Meter Size (1) ❑ .. Water Only Meter Size 0...Right-of-way Use - Profit for less than 72 hours 0...Right-of-way Use — Potential Disturbance ❑... Work in Flood Zone ❑... Storm Drainage ❑...Abandon Septic Tank ❑...Curb Cut O... Pavement Cut 0...Looped Fire Line if ❑ .. Sewer Main Extension Public ❑ .. Water Main Extension Public 0 0 0... Grease Interceptor ❑... Channelization 0...Trench Excavation ❑... Utility Undergrounding WO # (2) " WO # (3) " WO # WO # (2) " WO # (3) " WO # WO # ❑ .. Deduct Water Meter Size " Private 0 Private 0 FINANCE INFORMATION Fire Line Size at Property Line _ Number of Public Fire Hydrant(s) O .. Water ❑ .. Sewer ❑ .. Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip H:Wpplications\Forms-Applications On Line \2012 Applications\permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 3 of 4 f � DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $979.05 D18-0067 Address: 5709 S 152ND PL BLDG E Apn: 1157200360 $479.03 DEVELOPMENT $456.43 PERMIT FEE R000.322.100.00.00 0.00 $451.93 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $22.60 TECHNOLOGY FEE R000.322.900.04.00 0.00 $22.60 D18-0068 Address: 5717 5 152ND PL BLDG D Apn: 1157200360 $500.02 DEVELOPMENT $476.42 PERMIT FEE R000.322.100.00.00 0.00 $471.92 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $23.60 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R14144 R000.322.900.04.00 0.00 $23.60 $979.05 Date Paid: Tuesday, April 03, 2018 Paid By: ROOFTECH INC Pay Method: CHECK 1486 Printed: Tuesday, April 03, 2018 2:21 PM 1 of 1 CRWSYSTEMS / '. Cash Register Receipt City of Tukwila Receipt Number 113 0976 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $618.51 D18-0067 Address: 5709 S 152ND PL BLDG E Apn: 1157200360 $302.56 Credit Card Fee $8.81 Credit Card Fee R000.369.908.00.00 0.00 $8.81 DEVELOPMENT $293.75 PLAN CHECK FEE R000.345.830.00.00 0.00 $293.75 D18-0068 Address: 5717 S 152ND PL BLDG D Apn: 1157200360 $315.95 Credit Card Fee $9.20 Credit Card Fee R000.369.908.00.00 0.00 $9.20 DEVELOPMENT $306.75 PLAN CHECK FEE R000.345.830.00.00 0.00 ? $306.75 TOTAL FEES PAID BY RECEIPT: R13976 $618.51 Date Paid: Monday, March 12, 2018 Paid By: HERIBERTO BAHENA Pay Method: CREDIT CARD 06726G Printed: Monday, March 12, 2018 2:16 PM 1 of 1 CPWSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Dig -00b8 P oject: qTyp tion: f Inspection: dres 7/ 7 S, 152 PL Date Called: Special Instructions: G SL(� b �---� Date Wanted: J_ / 2T�2,0)g-�.m, 5 0 p.m. Requester: ,.gyp/�/ f V, X 47 6 ,/�/5' 42141 Phone No: 204 .$F5/ .2/9/ 0Approved per applicable codes. Corrections required prior to approval. COMMENTS: ok---8014)/k6. Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 DIS "co,' Project:.T 'Ali_) .rrk4 • �s 'e of Inspection: il; —:_tit. Address: it Pt-,�ce. 5 -in a l52 Date Called: Special Instructions: Date Wanted: 10 -Zoe a.m. Cx Bi4- P.m. Requester: Phone No: 6Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS. CaAI-17n.ue` Inspector: 0j2 c Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. it REVISIONS No changes shit he made to the scope ^f'"'r ',"thot.prior approval of +"•;'a Su;Ioing Division. I �- svio will require a new plan submittal end may Inc:Lida additional plan review fees. FILE COPY Permit No. -OO& Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is 9knowledged: By: Date: O 1-1 %6 3/ / City of Tukwila BUILDING DIVISION ;Sr:. Sr:`� \ c��f`►73D PERMIT FOR: 1 1- <echanical E_ 'iectrical I3'Piumbing 1._as Piping i% y of Tukwila f/ t s!`_`'I G DIVISION REVIEWED FOR CIODE COMPLIANCE MAR 2 7 2018 A -41 - City of Tukwila DU1LDiiy _ RECEIVED CITY OF TUKWILA MAR 12 2018 PERMIT CENTER 4 A) L PERMIT CENTER NC COMMERCIAL AND RESIDENT/AL ROOFTECH, INC 1621 S 257th Street, Des Moines, WA 98198 Phone: (206) 851-2194 TO: Pyramid Property LLC PO Box 40252, Bellevue, WA 98015 Phone: (206) 246-3060 ROOFING- SOLUTIONS hbc@rooftech-inc.com pyramidpointe@comcastnet CONTRACT'S ATTACHMENT "A" Superior Service - Quality Products. This document is not valid beyond thirty (30) days of issuance, due to the fluctuation in the price of the materials. PSN JOBSITE: LEASING OFFICE AND BUILDING D. 5709 S 152nd PI, Tukwila, WA 98188 Scope of work: Remove the existing shingles roof and haul away all debris from property. Install Ice & Water Shield (peel and stick) on valleys. Install synthetic underlayment on the roof deck Install new edges metal flashings, dryers vents, and pipes flashings. Install Certainteed Landmark Pro Shingles Install new ridge vent to let the building breath. Apply sealant wherever needed to prevent Teaks Clean all debris from work area every day We adhere to all area building codes and apply for all necessary building permits. We will keep clean and safe the jobsite every day, the roof will remain water proof all the time while the roof replacement is performed. RECEIVED CITY OF TUKWILA MAR 12 2018 PERMIT CENTER RoofRunnerTM lightweight synthetic polymer -based CertainTeed SAINT-GOBAIN underlayment outperforms felt and outclasses other synthetics. Designed for use on roof decks as a water-resistant layer beneath asphalt roofing shingles, this scrim -reinforced underlayment includes a special top surface treatment that provides excellent slip resistance, even when wet. Large roll size - 4 ft wide x 250 ft long - speeds application. ROOFRUNNE RTM FILO Lightweight Synthetic Underlayment CertainTeed SAINT-GOBAIN SPECIFICATIONS • Dimensions: 48" wide x 250' • Roll Size: 1,000 sq. ft. • Coverage: 937.5 sq. ft. • Weight: 23 lbs. • UV Exposure: 90 -day (based on standard accelerated QUV testing) • Warranty: See Limited Warranty for Details • Rolls per Pallet STANDARDS AND CODES RoofRunner conforms to: • Physical requirements of both ASTM D226 and D4869 • UL 790 / ASTM E108 Class Fire Resistance with Class A Roof Shingle EVIEWED FOR DE COMPLIANCE APPROVED MAR 2 7 2018 w kwiia ICC -ES AC188 City of Tu RECEIVED Florida Approval FL 2184CITY OF TUKWILA p E s-o0ea MAR 12 2018 PERMIT CENTER CertainTeed Corporation ROOFING • SIDING • TRIM • DECKING • RAILING • FENCE • GYPSUM • CEILINGS • INSULATION 20 Moores Road Malvern, PA 10385 Professional: 800.233-8000 Consumer: 800-782-8777 c.ertainteed. com '37I1 Cerl.a ,Teed Corporation.. Printed in Uln USA. Code No10203691 Technical Data Sheet LANDMARKTM Premium Shingles LANDMARK Pro/ArchitectTM 80 Shingles (NW Region only) LANDMARKT" aro Shi'1gies LANDMARKTM Shingles PRODUCT INFORMATION LandmarkTM shingles reflect the same high manufacturing standards CeriaCeriainTeed SAINT-GOBAIN and superior warranty protection as the rest of CertainTeed's line of roofing products. Landmark Premium (and Algae Resistant -AR), Landmark Pro (and AR) and Landmark (and AR) are built with the industry's toughest fiber glass mat base, and their strict dimensional tolerance assures consistency. Complex granule color blends and subtle shadow lines produce a distinctive color selection. Landmark is produced with the unique NailTrakTM nailing feature. Please see the installation instruction section below for important information regarding NailTrakTM In the Northwest (NW) Region Landmark Pro (AR) is double -branded as Landmark Pro/Architect 80 (AR). Landmark algae -resistant (AR) shingles have the additional attribute of resisting the growth of algae especially in damp regions. AR shingles are not available in all regions Colors: Please refer to the product brochure or CertainTeed website for the colors available in your region. Limitations: Use on roofs with slopes greater than 2" per foot. Low -slope applications (2" to 4" per foot) require additional underlayment. In areas where icing along eaves can cause the back-up of water, apply CertainTeed WinterGuardTM Waterproofing Shingle Underlayment, or its equivalent, according to application instructions provided with the product and on the shingle package. REVIEWED Product Composition: Landmark series shingles are composed of a fiber glass mat base., Ce r,n- - FOR coated mineral granules are tightly embedded in carefully refined, water-resistant asphalt. $Wo re swaittiFLIAitCE the shingle are firmly laminated together in a special, tough asphaltic cement. All Landmark shingl�i�n�:-`-, self-sealing adhesive strips. Applicable Standards ASTM D3018 Type I ASTM D3462 ASTM E108 Class A Fire Resistance ASTM D3161 Class F Wind Resistance ASTM D7158 Class H Wind Resistance UL 790 Class A Fire Resistance Technical Data: Weight/Square (approx.) Dimensions (overall) Shingles/Square (approx.) Weather Exposure Landmark (and AR) 229 / 240 Ib** 13 1/4" x 38 3/4" 65 5 5/8" *Includes "Landmark Pro AR/Architect 80" **Dependent on manufacturing location MAR 2 7 7.018 ICC Evaluation Report ESR -1389 ICC Evaluation Report ESR -3537 Cityof l ul�Ila CSA Standard A123.5 (Regional) 4 Miami -Dade Product Control Approll ��giatAK3 Florida Product Approval # FL5444 (�Regional)– TDI Windstorm Resistance (Regional) Landmark Pro* (and AR) 250 / 270 Ib** 13 1/4" x 38 3/4" 66 5 5/8" bi8 OO&'B Landmark Premium (and AR) 300 Ib 13 1/4" x 38 3/4" 66 5 5/8" RECEIVED CITY OF TUKWILA NEAR 12 2018 PERMIT CENTER Technical Data Sheet (Continued) Landmark Shingles Page 2 of 3 INSTALLATION The following is a general summary of the installation methods. Detailed installation instructions are supplied on each bundle of Landmark shingles and must be followed. Separate application sheets may also be obtained from CertainTeed. Roof Deck Requirements: Apply shingles to minimum 3/8" thick plywood, minimum 7/16" thick non - veneer (e.g. OSB), or minimum 1" thick (nominal) wood decks. The plywood or non -veneer decks must comply with the specifications of APA -The Engineered Wood Association. Ventilation: Provisions for ventilation should meet or exceed current HUD Standards. To ensure adequate balance ventilation, use a combination of continuous ridge ventilation (using CertainTeed Ridge Vent products, or a comparable product with an external baffle) combined with soffit venting. Valleys: Valley liner must be applied before shingles. The Closed -Cut valley application method is recommended, using CertainTeed WinterGuard Waterproofing Shingle Underlayment or its equivalent to line the valley prior to being fully covered by the shingles. Underlayment: On slopes 4" per foot or greater, CertainTeed recommends one layer of DiamondDeckTM Synthetic Underlayment, or Roofers' SelectTM High -Performance shingle underlayment, or shingle underlayment meeting ASTM D226, D4869 or ASTM D6757. Always ensure sufficient deck ventilation, and take particular care when DiamondDeck or other synthetic underlayment is installed. For UL fire rating, underlayment may be required. Corrosion -resistant drip edge is recommended and should be placed over the underlayment at the rake and beneath the underlayment at the eaves. Follow manufacturer's application instructions. On low slopes (2" up to 4" per foot), one layer of CertainTeed's WinterGuard Waterproofing Shingle Underlayment (or equivalent meeting ASTM D1970) or two layers of 36" wide felt shingle underlayment (Roofers' Select High -Performance Underlayment or product meeting ASTM D226, D4869 or ASTM D6757) lapped 19" must be applied over the entire roof, ensure sufficient deck ventilation. When DiamondDeck or other synthetic underlayment is installed, weather -lap at least 20" and ensure sufficient deck ventilation. When WinterGuard is applied to the rake area, the drip edge may be installed under or over WinterGuard. At the eave, when WinterGuard does not overlap the gutter or fascia, the drip edge should be installed under WinterGuard. When WinterGuard overlaps the fascia or gutter, the drip edge or other metal must be installed over it. Follow manufacturer's application instructions. Fastening (NailTrakTM): Low & Standard Slopes: On low and standard slopes, four nails are required per shingle. There are three nail lines on NailTrak shingles. Position nails vertically between the upper and lower nailing -guide lines. It is acceptable to nail between either the middle and lower lines, or between the upper and middle lines. Nails must be of sufficient length to penetrate into the deck 3/4" or through the thickness of the decking, whichever is less. They are to be located 1" and 12" in from each side of the shingle (see instructions on product wraps.) Nails are to be 11 or 12 gauge, corrosion -resistant roofing nails with 3/8" heads. Steep Slopes: On slopes greater than 21" per foot, fasten each shingle with six nails and four spots of roofing cement placed under each shingle according to application instructions provided on the shingle package. Fasteners must penetrate the two -layer common bond area that is indicated by the middle and lower NailTrak lines, also illustrated on the shingle package. Technical Data Sheet (Continued) Landmark Shingles Page 3 of 3 Application: The recommended application method is the 'Five -Course, Diagonal Method' found on each bundle of shingles. In this method, shingle course offsets are 6" and 11". Instructions also may be obtained from CertainTeed. These shingles may be used for new construction or for reroofing over existing Metric -sized shingles. Flashing: Use corrosion -resistant metal flashing. Hips and Ridges: For capping hip and ridge apply CertainTeed Shadow Ridge TM Cedar CrestTM or Mountain Ridge TM shingles of a like color. MAINTENANCE These shingles do not require maintenance when installed according to manufacturer's application instructions. However, to protect the investment, any roof should be routinely inspected at least once a year. Older roofs should be looked at more frequently. WARRANTY Landmark Premium (and AR), Landmark Pro/Architect 80 AR, Landmark Pro (and AR), and Landmark (and AR) shingles carry a lifetime limited, transferable warranty to the consumer against manufacturing defects. In addition, Landmark Premium (and AR), Landmark Premium/Architect 80, Landmark Pro (and AR), and Landmark (and AR) carry 10 -years of SureStartTM Protection. For specific warranty details and limitations, refer to the warranty itself (available from the local supplier, roofing contractor or on-line at www.certainteed.com). FOR MORE. INFORMATION Sales Support Group: 800-233-8990 Web site: www.certainteed.com See us at our on-line specification writing tool, CertaSpec, at www.certainteed.com/certaspec. CertainTeed Roofing 20 Moores Road Malvern, PA 19355 © Copyright CertainTeed Corporation, 2016 All rights reserved. Updated: 02/2016 SAINT-GOBAIN CertainTeed 'PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0068 DATE: 03/12/18 PROJECT NAME: PYRAMID POINTE APTS - BLDG D SITE ADDRESS: 5717 S 152 PL X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: ,wL ����V1,0 Building Division Public Works /rm M Fire Prevention1111 Structural Planning Division nPermit Coordinator El PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 03/13/18 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved nApproved with Conditions Corrections Required ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 04/10/18 n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 ROOFTECH INC r Horne Espanol Contact: Safety & Health Claims & Insurance CWashington State Department of Labor & Industries Search L&I Page 1 of 2 �• t A -Z Index Help My L&I Workplace Rights Trades & Licensing ROOFTECH INC Owner or tradesperson Principals BAHENA CARRANZA, HERIBERTO, PRESIDENT Doing business as ROOFTECH INC WA UBI No. 603 183 304 1621 S 257TH ST DES MOINES, WA 98198 206-851-2194 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. ROOFTI*882DZ Effective — expiration 03/09/2012— 03/09/2020 Bond Wesco Insurance Co Bond account no. 46W B083631 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 02/27/2017 02/28/2017 Expiration date Until Canceled Bond history Insurance ........................ Houston Specialty Ins Co $1,000,000.00 Policy no. TEN -19702 Received by L&I Effective date 07/12/2017 07/12/2017 Expiration date 07/12/2018 Insurance history Savings ......._..... No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603183304&LIC=ROOFTI* 882DZ&SAW= 4/3/2018 ROOFTECH INC License Violations No license violations during the previous 6 y,,.d period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 231,727-00 Doing business as ROOFTECH INC Estimated workers reported Quarter 4 of Year 2017 "1 to 3 Workers" L&I account contact T1 / JAN BENTLEY (360)902-4652 - Email: STR0235@Ini.wa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 10/26/2015 Inspection no. 317936593 Location 4015 South Meridan Puyallup, WA 98373 Inspection results date 12/27/2012 Inspection no. 316575646 Location 2342 Tacoma Avenue S. Tacoma, WA 98402 Violations Violations Page 2 of 2 © Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603183 304&LIC=ROOFTI * 882DZ&SAW= 4/3/2018