HomeMy WebLinkAboutPermit D18-0113 - INDUSTRIAL REVOLUTION - STORAGE RACKSINDUSTRIAL REVOLUTION 5835 SEGALE PARK C DR D18-0113 Parcel No: Address: \ City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 3523049115 5835 SEGALE PARK C DR DEVELOPMENT PERMIT Project Name: INDUSTRIAL REVOLUTION Permit Number: D18-0113 Issue Date: 5/29/2018 Permit Expires On: 11/25/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: SEGALE PROPERTIES LLC PO BOX 88028 , TUKWILA, WA, 98138 CHRIS LING 9800 40TH AVE S , SEATTLE, WA, 98118 ENGINEERED PRODUCTS, A PAPE CO 9800 40TH AVE S , SEATTLE, WA, 98188 ENGINPC931C0 INDUSTRIAL REVOLUTION 5835 SEGALE PARK C DR , TUKWILA, WA, 98188 Phone: (206) 394-3327 Phone: (206) 394-3300 Expiration Date: 2/20/2019 DESCRIPTION OF WORK: INSTALLATION OF SELECTIVE STYLE RACKING Project Valuation: $70,000.00 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $2,100.78 Occupancy per IBC: S-2 Water District: HIGHLINE Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 Permit Center Authorized Signature: Date: —"- I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regula 'r: con i�ction or the performance of work. I am authorized to sign and obtain this development ger it - afire; the coir ditions attached to this permit. Signatur •: / Print Name: (/i'/ /i 5 <� Date: < �L c� This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***ELECTRICAL PERMIT CONDITIONS*** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296-46B WAC and the Washington Cities Electrical Code. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. 8: ***BUILDING PERMIT CONDITIONS*** 9: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. r 1 10: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 11: The special inspections and verifications for concrete construction shall be as required by IBC Chapter 17, Table 1705.3. 12: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 13: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 26: TO SCHEDULE ALL FIRE INSPECTIONS CALL 206-575-4407. 17: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 14: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 15: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 16: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 18: Maintain fire extinguisher coverage throughout. 20: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 21: Clearance between ignition sources, such as light fixtures, heaters and flame -producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 22: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.3.1) 23: Flue spaces shall be provided in accordance with International Fire Code Table 3208.3. Required flue spaces shall be maintained. 24: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 25: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 4_. CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov f1 • Building Permit No. l ` 0 113 Project No. 4-)3-f Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 5.3 6E61P00for G Suite Number: Floor: Tenant Name: 1 IYO LST,f- AL" - PROPERTY OWNER Name: C iv:%. 1....;,,,s Name: prl re pIGci:c5 LL -l - Address: FO .SOK. D gOa'r City: "r tt....A tt State: W A Zip: 41$13$ T� 1 l6 CONTACT PERSON - person receiving all project communication Name: C iv:%. 1....;,,,s Address: etEop,J1 O � S - State:, Zip: It ii City: �th& Phone: Fax: ?Ay 3n 1 Fax: 906 S-7 S' to 4 8- b Email: 6441..,s L l: cPO FVJi • Ca -.---- GENERAL CONTRACTOR INFORMATION Company Name:eAt p Address: q ij0 es A6 S City State Zip: cis,/ i g {{ (i� Phone0. ��X �3p.'� Fax: - / Contr Reg No.:60iAlp4 %31Ct7Exp Date: elin'rq Tukwila Business License No.: /001D0 H:\Applications\Porms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh New Tenant: ❑ Yes ARCHITECT OF RECORD Company Name: sir Jam' ` vT E,•.3„i"S i Engineer Name: IM,wwbQ L I O Zdr) Company Name: City: L.A 1/62.4 State: 1. Zip: gasp Phone gito 1/c1 Fax: - o Ivuo 1 Ivo Architect Name: r/ t.City: T� 1 l6 Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Company Name: sir Jam' ` vT E,•.3„i"S i Engineer Name: IM,wwbQ L I O Zdr) Address: N1 VV 104h ork City: L.A 1/62.4 State: 1. Zip: gasp Phone gito 1/c1 Fax: - o Ivuo 1 Ivo Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: / /VOlrl- S Pre { (--(UJL JS -7-c^ Address: z.s- <,r-7> C 6 ipn(�L--bf r/ t.City: T� 1 l6 State: A_ Zip:9 q I Page 1 of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 70 �J Existing Building Valuation: $ Describe the scope of work (please provide detailed information): A 1730—Ano✓- 0e Se -t4 - vr( 61..Eke. Qac&k-t/lS Will there be new rack storage? JYes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 ApplicationsWermit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1n Floor 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 ApplicationsWermit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 'N ' O : THO E GENT: Signature: Date: (, 01-)t Print Name: Day Telephone: 3'? Mailing Address: C/ /1— / & ` ( /rE State Zip H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh City Page 4 of 4 Receipt Number ." R14603 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY ` PAID $1,284.58 D18-0113 Address: 5835 SEGALE PARK C DR Apn: 3523049115 $1,284.58 DEVELOPMENT $1,223.62 PERMIT FEE R000.322.100.00.00 0.00 $1,219.12 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $60.96 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R14603 R000.322.900.04.00 0.00 $60.96 $1,284.58 Date Paid: Tuesday, May 29, 2018 Paid By: ENGINEERED PRODUCTS Pay Method: CHECK 051873 Printed: Tuesday, May 29, 2018 2:11 PM 1 of 1 s , SYSTEMS Cash Register Receipt. City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $816.20 D18-0113 Address: 5835 SEGALE PARK C DR Apn: 3523049115 $816.20 Credit Card Fee $23.77 Credit Card Fee R000.369.908.00.00 0.00 $23.77 DEVELOPMENT $792.43 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R14317 R000.345.830.00.00 0.00 $792.43 $816.20 Date Paid: Monday, April 23, 2018 Paid By: CHRISTOPHER LING Pay Method: CREDIT CARD 023775 Printed: Monday, April 23, 2018 1:19 PM 1 of 1 `' " ` SYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit Di$ -0113 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36"111/ Permit Inspection Request Line (206) 438-9350 Pr, 'ect: 1r -ir k L ` I eve wo e of Inspection: v,1 WI rib Fi orAL Address: 5835 6,Le- Pik Date Called: Special Instru ns: Date Wanted: cn.m. c2ofe II_ Requester: Phone No: applicable codes. 0 Corrections required prior to approval. Approved per COMMENTS: .� iii VG.1, �Lh. .. y.r ,, y� �p Date: / 1/ zag( REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Retain a copy with permiINSPECTION RECORD �1��Or�3 PERMIT Na. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Pr ect:, hcksira ?eiVo 1 �to� Ty` of Ins a ti n: �,8 I nq FiNTIAL Address: 5835 M. iPi9-rtgi-9 C A %ve. Special Instructio : t V\,, Date Wanted: 5-30-2o)/ p.m., Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 11 t.k. teat v Fi✓l67(- l it(r,r+1 pi ---77) ,S C_Le;t .1-A2crec-fre.ki —E-7-- °-"-.7. .4 v <tic ry i's 4 9pv-c;, p t 63yva,ille e.,/' t-\5 CF) </ktv tic, r c rt -LR , pe. ,- • rx, Do uk.LIr a vk;46 I (L1)(kJ/Ole—es re._c‘, . a i ec,1,,, Lt',,,.fr %, 1- Si f r Lt: v1 %t -s ) kJe_e_d ',4/1---hri-/-7-re-4/ eiy,,it.r4, Inspector: Date- 3Q _ 20t , REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 1 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE -DEPARTMENT 206-575-4407 Project: j ( n 61 � t 51 Ca/Ze4o (v U Type of Inspectipn �<I`-ac Address:Contact Suite #: cj 3 P6-11 C Person�\� ti vt 6 Special Instructions: Monitor: loot ei (A.,t c4.-- Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: S i&e r 1 74 -Ob 0(s�� Needs Shift Inspection: Sprinklers: Y* 5 Hrs.: Fire Alarm: ye -5 Hood & Duct: Monitor: loot ei (A.,t c4.-- Pre -Fire: Permits: Occupancy Type: tJ'^r-e 1 Inspector: `- Date: ‘.) h f Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to.. schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 rIT. (saw.tstt - Structural Engineering EE Design, Inc REVIEWED FOR CODE COMPLIANCE APPROVED MAY 252018 City of Tukwila BUILDING DIVISION 1815 Wright Ave La Verne, Ga. 91750 Tel: 909-5964351 Fax: 909-596-7186 Protect Name : INDUSTRIAL REVOLUTION Protect Number : LV -041218-8 Date : 04/18/18 Street Address: 5835 SEGALE PARK DRIVE, SUITE G Glty/State : TUKWILA, WA 98188 Scope of Work : SELECTIVE bis 0113 RECEIVED WV V OF TUKWILA APR 23 2010 Structural Engineering & Design Inc. 1815 Wright Ave La Verne, CA 91750 Tel: 909.596.1351 Fax: 909.596.7186 By: S.P. Project: INDUSTRIAL REVOLUTION Project #: LV -041218-8 TABLE OF CONTENTS Title Page 1 Table of Contents 2 Design Data and Definition of Components 3 Critical Configuration 4 Seismic Loads 5 to 6 Column 7 Beam and Connector 8 to 9 Bracing 10 Anchors 11 Base Plate 12 Slab on Grade 13 Other Configurations 14 tC 1 INDUSTRIAL REVOLUTION -TYPE 2 SGL.xIs Page of j C, 4/ 1 7/20 1 8 Structural Engineering & Design Inc. 1815 Wright Ave La Verne, CA 91750 Tel: 909.596.1351 Fax: 909.596.7186 By: S.P. Project: INDUSTRIAL REVOLUTION Project#: LV -041218-8 Design Data 1) The analyses herein conforms to the requirements of the: 2015 IBC Section 2209 ANSI MH 16.1-2012 Specifications for the Design of Industrial .5&•e/Storage Racks '2012 RMI Rack Design Manual" ASCE 7-10, section 15.5.3 2) Transverse braced frame steel conforms to ASTM A570, Gr.55, with minimum strength, Fy=55 ksi Longitudinal frame beam and connector steel conforms to ASTM A570, Gr.55, with minimum yield, Fy=55 ksi All other steel conforms to ASTM A36, Gr. 36 with minimum yield, Fy= 36 ksi 3) Anchor bolts shall be provided by installer per ICC reference on plans and calculations herein. 4) All welds shall conform to AWS procedures, utilizing E70xx electrodes or similar. All such welds shall be performed in shop, with no field welding allowed other than those supervised by a licenseddeputy inspector. 5) The existing slab on grade is 6" thick with minimum 4000 psi compressive strength. Allowable Soil bearing capacity is 750 psf. The design of the existing slab is by others. 6) Load combinations for rack components correspond to 2012 RMI Section 2.1 for ASD level load criteria Definition of Components Frame Height Beam Product Beam Spacing Beam Length Front View: Down Aisle (Longitudinal) Frame Column Beam to Column Connector Base Plate and Anchors Panel Height Horizontal Brace Diagonal Brace Frame Depth Section A: Cross Aisle (Transverse) Frame INDUSTRIAL REVOLUTION -TYPE 2 SGL.xIs Page3 of 1 Co 4/17/2018 Structural Engineering & Design Inc. 1815 Wright Ave La Verne, CA 91750 Tel: 909.596.1351 Fax: 909.596.7186 By: S.P. Project: INDUSTRIAL REVOLUTION Project #: LV -041218-8 Configuration & Summary: TYPE 2 SELECTIVE RACK 144 IN BAY S/R I 264" 84,E 78" 144" 264" 60" 54" 54" 36" 36" 44" -7y **RACK COLUMN REACTIONS ASD LOADS AXIAL DL= 113 /b AXL4L LL= 3,750 /b SEJSMICAXIAL Ps=#/- 9,659 Ib BASE MOMENT= 8,000 in /b Seismic Criteria # Bm Lvls Frame Depth Frame Height # Diagonals Beam Length Frame Type Ss=1.426, Fa=1 3 44 in 264.0 in 5 144 in Single Row Component Description STRESS Column Fy=55 ksi SPCRK FH-30/3x3x12ga P=2575 Ib, M=24612 in -Ib 0.58-0K Column & Backer To Level 1 SPCRK FH30-FS-8/3x3x12ga/3x1-5/8x14ga p= 3863 Ib, M= 43652 in -Ib 0.68-0K Beam Fy=55 ksi SpaceRak S8416C 4.125 in x 0.06 in Lu=144 in Capacity: 2761 lb/pr 0.91 -OK Beam Connector Fy=55 ksi Lvl 1: 4 pin OK l Mconn=26538 in -Ib Mcap=31729 in -Ib 0.84 -OK Brace -Horizontal Fy=55 ksi Sperack 1-1/2x1-1/4x14ga 0.31 -OK Brace -Diagonal Fy=55 ksi Sperack 1-1/2x1-1/4x14ga 0.49 -OK Base Plate Fy=36 ksi 8x8x3/8 I Fixiiyy= 8000 in -Ib 0.63 -OK Anchor 4 per Base 0.5" x 3.25" Embed POWER SDII ESR 2502 Inspection Reqd (Net Seismic Uplift=7796 Ib) 0.967 -OK Slab & Soil 6" thk x 4000 psi slab on grade. 750 psf Soil Bearing Pressure 0.43 -OK Level Load** Per Level Beam Spcg Brace Story Force Transv Story Force Longit. Column Axial Column Moment _ Conn. Moment Beam Connector 1 2,500 Ib 78.0 in 36.0 in 300 Ib 224 Ib 3,863 Ib 43,652 "# 26,538 "# 4 pin OK 2 3 2,500 Ib 84.0 in 2,500 Ib 84.0 in 36.0 in 54.0 in 54.0 in 60.0 in 624 Ib 465 Ib 2,575 Ib 24,612 "# 16,454 "# 4 pin OK 948 Ib 707 Ib 1,288 Ib 14,841 "# 7,840 "# 4 pin OK ** Load defined as product weight per pair of beams Total: 1,872 Ib 1,396 Ib Notes BEAM WITH FULL WELD. INDUSTRIAL REVOLUTION -TYPE 2 SGL.xls Page of 4/17/2018 Structural Engineering & Design Inc. 1815 Wright Ave La Verne, CA 91750 Tel: 909.596.1351 Fax: 909.596.7186 By: S.P. Project: INDUSTRIAL REVOLUTION Project #: LV -041218-8 Seismic Forces Configuration: TYPE 2 SELECTIVE RACK 144 IN BAY S/R Lateral analysis is performed with regard to the requirements of the 2012 RMI ANSI MH 16.1-2012 Sec 2.6 & ASCE 7-10 sec 15.5.3 Transverse (Cross Aisle) Seismic Load V= Cs*Ip*Ws=Cs*Ip*(0.67*P*Prf+D) Csl= Sds/R = 0.2377 Cs2= 0.044*Sds = 0.0418 Cs3= 0.5*S1/R = 0.0665 Cs -max= 0.2377 Base Shear Coeff=Cs= 0.3566 Level 1 2 3 PRODUCT LOAD P 2,500 Ib 2,500 Ib 2,500 Ib Cs -max * Ip= Vmin= Eff Base Shear=Cs= Ws= 0.3566 0.015 0.3566 Transverse Ekvation (0.67*PLRF1 * PL)+DL (RMI 2.6.2) = 5,250 Ib Vtransv=Vt= 0.3566 * (225 lb + 5025 Ib) Etransverse= 1,872 Ib Lit' nit States Level Transverse sei mk shear per upright P*0.67*PRFI DL 1,6751b 751b 1,675 Ib 75 lb 1,675 Ib 75 Ib hi. 78 in 162 in 246 in wi*hi 136,500 283,500 430,500 Ss= S1= Fa= Fv= Sds=2/3*Ss*Fa= Sd1=2/3*Sl*W= Ca=0.4*2/3*Ss*Fa= (Transvefse, Braced Frame Dr.) R. Ip= PRFl Pallet Height=hp= DL per Beam LvI= 300.4 Ib 624.0 Ib 947.6 Ib 1.426 0.532 1.000 1.500 0.951 0.532 0.3803 4.0 1.5 10 <- 72.0 in::::_,;. 75 Ib Fl*(hi+hp/2) 34,246-# 123,552-# 267,223-# sum: P=7500 Ib 5,025 Ib Longitudinal (Downaisle) Seismic Load Similarly for longitudinal seismic loads, using R=6.0 Csl=Sd1/(T*R)= 0.1773 Cs2= 0.0418 Cs3= 0.0443 Cs -max= 0.1773 Level PRODUC LOAD P 225 Ib W=5250 Ib 850,500 Ws= (0.67 * PLRF2 * P) + DL = 5,250 Ib Cs=Cs-max*Ip= 0.2660 PRF2= 1.0 (Longitudinal, Unbraced Dir.) R= 6.0 T= 0.50 sec Vlong= 0.26595 * (225 Ib + 5025 lb) Elongitudinal= 1,396 Ib tnnitSbtes Love itnngit seismic shearperupngit P*0.67*PRS DL hi wi*hi 1,872 Ib R 2=425,021 front View 1 2 3 2,500 Ib 2,500 Ib 2,500 Ib 1,675 Ib 1,675 Ib 1,675 Ib 75 Ib 75 Ib 75 lb 78 in 162 in 246 in 136,500 283,500 430,500 224.0 lb 465.3 Ib 706.6 Ib sum: 5,025 Ib 225 Ib W=5250 Ib 850,500 1,396 Ib INDUSTRIAL REVOLUTION -TYPE 2 SGL.xIo Page of (c, 4/17/2018 Structural Engineering & Design Inc. 1815 Wright Ave La Verne, CA 91750 Tel: 909.596.1351 Fax 909.596.7186 By: S.P. Project: INDUSTRIAL REVOLUTION Downaisle Seismic Loads Configuration: TYPE 2 SELECTIVE RACK 144 IN BAY S/R Project #: LV -041218-8 Determine the story moments by applying portal analysis. The base plate is assumed to provide partial fixity. Seismic Story Forces Vlong= 1,3961b Vco1=Vlong/2= 698 Ib F1= 2241b F2= 465 Ib F3= 707 Ib Seismic Story Moments Typical Game made Tibutary rea oftwocolumns of rack me 4 r 41- 41- 1— f Front View Conceptual System Sde View Typical Frame made of two columns 1.1 T1 Top View v .)q Mbase-max= 8,000 in -Ib <_== Default capacity Mbase-v= (Vcol*hleff)/2 = 25,826 in -Ib <=== Moment going to base Mbase-eff= Minimum of Mbase-max and Mbase-v M 1-1= 8,000 in -Ib [Vcol * hleff]-Mbase-eff (698 Ib * 74 in) -8000 in -Ib 43,652 in -Ib Mseis= (Mupper+Mlower)/2 Mseis(1-1)= (43652 in -Ib + 24612 in-Ib)/2 = 34,132 in -lb hl-eff= hl - beam clip height/2 = 74 in M 2-2= [Vcol-(F1)/2] * h2 = [698 Ib - 232.71b]*84 in/2 = 24,612 in -Ib Mseis(2-2)= (24612 in -Ib + 14841 in-Ib)/2 = 19,726 in -Ib Beam to Column Elevation rho= 1.0000 CO1 Summary of Forces LEVEL 1 2 3 hi 78 in 84 in 84 in Axial Load 3,8631b 2,575 Ib 1,288 Ib Column Moment** 43,652 in -lb 24,612 in -Ib 14,841 in -Ib Mseismic** 34,132 in -Ib 19,726 in -Ib 7,420 in -Ib Mend -fixity Mconn** 3,780 in -Ib 26,538 in -Ib 3,780 in -Ib 16,454 in -Ib 3,780 in -Ib 7,840 in -Ib Beam Connector 4 pin OK 4 pin OK 4 pin OK Mconn= (Mseismic + Mend-fixity)*0.70*rho Mconn-allow(4 Pin)= 31,729 in -Ib **all moments based on limit states level loading INDUSTRIAL REVOLUTION -TYPE 2 SGL.xks Page 6 of 16 4/17/2018 Structural Engineering & Design Inc. 1815 Wright Ave La Verne, CA 91750 Tel: 909.596.1351 Fax: 909.596.7186 By: S.P. Project: INDUSTRIAL REVOLUTION Project #: LV -041218-8 Column (Longitudinal Loads) Configuration: TYPE 2 SELECTIVE RACK 144 IN BAY S/R Section Properties Loads Section: SPCRK F130-FS-8/3x3x12ga/3x1-5/8x14ga Aeff = 1.425 inA2 Ix = 2.273 inA4 Sx = 1.510 inA3 rx= 1.263 in Of= 1.67 E= 29,500 ksi Considers loads at level 1 Iy = 2.798 inA4 Sy = 1.207 inA3 ry = 1.401 in Fy= 55 ksi Cmx= 0.85 Kx = 1.7 Lx = 75.9 in Ky = 1.0 Ly = 36.0 in Cb= 1.0 0.750 in COLUMN DL=D= 113 Ib COLUMN LIVE LOAD=P= 3,750 Ib Mcol= 43,652 in -Ib Sds= 0.9507 1+0.105*Sds= 1.0998 1.4+0.14Sds= 1.5331 1+0.14Sds= 1.1331 0.85+0.14*Sds= 0.9831 B= 0.7000 rho= 1.0000 Axial Analysis Critical load cases are: RMT 5ec 21 Load Case 5:: (1 #0.105*Sds)D # 0.75*(1.4#0.14Sds)*B*P # 0.75*(0.7*Mo*E)<= L0, ASD Method axial load coef: 0.80487645 * P seismic moment coeff 0.5625 * Mco/ Load Case 6:: : (1#0.14*Sds)D # (0.85#0.14Sds)*B*P # (0.7*rho*E)<= 14 ASD Method axial load coeff: 0.68817 seismic moment coef 0.7 * Mco/ By analysis, Load case 6 governs utilizing loads as such Axial=Pax 1.133098`112.5 Ib + 0.983098*0.7*3750 Ib = 2,708 Ib Moment=Mx= 0.7*rho*Mcot = 0.525*43652 in -Ib = 30,556 in -Ib KxLx/rx = 1.7*75.9375'/1.263" = 102.2 Fe= nA2E/(KL/r)maxA2 = 27.9ksi Pn= Aeff*Fn = 39,706 Ib P/Pa= 0.13 Bending Analysis < 0.15 KyLy/ry = 1*36"/1.401" = 25.7 Fy/2= 27.5 ksi S2c= 1.92 Fe > Fy/2 Fn= Fy(1-Fy/4Fe) = 55 ksi*[1-55 ksi/(4*27.9 ksi)] = 27.9 ksi Pa= Pn/S2c = 397061b/1.92 = 20,680 lb CHECK: P/Pa + Mx/Max <_ 1.0 Pno= Ae*Fy = 1.425 inA2 *55000 psi = 78,375 Ib Max= My/S2f = 83050 in-Ib/1.67 = 49,731 in -Ib I x= {1/[1-(52c*P/Pcr)]}A-1 = {1/[1-(1.92*2708 lb/39711 Ib)]}A-1 = 0.87 Combined Stresses Pao= Pno/Sk = 78375lb/1.92 = 40,820 Ib Myield=My= Sx*Fy = 1.51 inA3 * 55000 psi = 83,050 in -Ib Pcr= nA2EI/(KL)maxA2 = nA2*29500 ksi/(1.7*75.9375 in)A2 = 39,711 Ib (2708 lb/20680 Ib) + (30556 in-lb/49731 in -Ib) = 0.68 ** For comparison, total column stress computed for load case 5is• < 1.0, OK (EQ C5-3) 61.096 ads 3142.01683125 lb Axial and M= 22917 in -/b INDUSTRIAL REVOLUTION -TYPE 2 SGL.xls Page of j (a 4/1 7/20 18 Structural Engineering & Design Inc. 1815 Wright Ave La Verne, CA 91750 Tel: 909.596.1351 Fax: 909.596.7186 By: S.P. Project: INDUSTRIAL REVOLUTION Project #: LV -041218-8 Column (Longitudinal Loads) Configuration: TYPE 2 SELECTIVE RACK 144 IN BAY Section Properties Section: SPCRK FH-30/3x3x12ga Aeff = 0.880 inA2 Ix = 1.520 inA4 Sx = 1.010 inA3 rx = 1.312 in S2f= 1.67 E= 29,500 ksi Loads Considers loads at level 2 Iy = 1.000 inA4 Sy = 0.659 inA3 ry= 1.064 in Fy= 55 ksi Cmx= 0.85 Kx = 1.7 Lx = 81.9 in Ky = 1.0 Ly = 36.0 in Cb= 1.0 3.000 in 1 Y 1 Y 1_ P I 05 x J X0.075 in 3.000 in COLUMN DL= 75 Ib COLUMN PL= 2,500 Ib Mcol= 24,612 in -Ib Sds= 0.9507 1+0.105*Sds= 1.0998 1.4+0.14Sds= 1.5331 1+0.14Sds= 1.1331 0.85+0.14*Sds= 0.9831 B= 0.7000 rho= 1.0000 Axial Analysis Critical toad cases are: RMI Sec 21 Load Case 5: : (1(0.105*Sds)D + 0.75*(1.4+0.145ds)*B*P + 0.75*(0.7*rfio*E)<= 1.0, ASD Method axial load coeff. 0.80487645 * P seismic moment coef 0.5625 * Mcol Load Case 6: : (1+0.14*Sds)D + (0.85+0.14Sds)*B*P + (0.7*rho*E)<= 14, ASD Method axia/load coeff0.68817 seismic moment coef 0.7 * Mar/ By analysis, Load case 5 governs utilizing loads as such Axial Load=Pax= X9998235'75 m + 0.75. 1.533098 = 0.7 * 2500 Ib = 2,095 Ib Moment=Mx= 0.75*0.7*rho*Mcol = 0.525*24612 in -Ib = 12,921 in -Ib KxLx/rx = 1.7*81.9375y1.312" KyLy/ry = 1*3671.064" = 106.2 = 33.8 Fe= nA2E/(KL/r)maxA2 = 25.8ksi Pn= Aeff*Fn = 22,730 Ib P/Pa= 0.18 > 0.15 Bending Analysis Fy/2= 27.5 ksi S2c= 1.92 Fe < Fy/2 Fn= Fe = nA2E/(KL/r)maxA2 = 25.8 ksi Pa= Pn/Qc = 22730 Ib/1.92 = 11,839 Ib Check: Pax/Pa + (Cmx*Mx)/(Max*px) <_ 1.0 P/Pao + Mx/Max <_ 1.0 Pno= Ae*Fy = 0.88 inA2 *55000 psi = 48,400 Ib Max= My/Qf = 55550 in-Ib/1.67 = 33,263 in -Ib px= {1/[1-(S2c*P/Pcr)]}A-1 = {1/[1-(1.92*2095lb/22809 Ib)}}A-1 = 0.82 Combined Stresses Pao= Pno/S2c = 484001b/1.92 = 25,208 Ib Myield=My= Sx*Fy = 1.01 inA3 * 55000 psi = 55,550 in -Ib Pcr= nA2EI/(KL)maxA2 = nA2*29500 ksi/(1.7*81.9375 in)A2 = 22,809 Ib (2095 Ib/11839 Ib) + (0.85*12921 in-Ib)/(33263 in-Ib*0.82) = 0.58 < 1.0, OK (2095 lb/25208 Ib) + (12921 in-lb/33263 in -Ib) = 0.47 < 1.0, OK (EQ C5-1) (EQ C5-2) ** For comparison, total column stress computed for load case 6 is: 39.0% :inq loads 1805.403851b Axial and M= 17228 in -lb INDUSTRIAL REVOLUTION -TYPE 2 SGL.xI5 Page 7, j of 1 (p 4/17/2018 Structural Engineering & Design Inc. 1815 Wriqht Ave La Verne, CA 91750 Tel: 909.596.1351 Fax: 909.596.7186 By: S.P. Project: INDUSTRIAL REVOLUTION Project #: LV -041218-8 BEAM Configuration: TYPE 2 SELECTIVE RACK 144 IN BAY SJR DETERMINE ALLOWABLE MOMENT CAPACITY A) Check compression flange for local buckling (B2.1) w= c - 2*t -2*r = 1.75 in - 2*0.06 in - 2*0.06 in = 1.510 in w/t= 25.17 l=lambda= [1.052/(k)^0.5] * (w/t) * (Fy/E)^0.5 = [1.052/(4)^0.5] * 25.17 * (55/29500)^0.5 = 0.572 < 0.673, Flange is fully effective B) check web for local buckling per section b2.3 fl(comp)= Fy*(y3/y2)= 50.29 ksi f2(tension)= Fy*(y1/y2)= 102.06 Icsi Y= f2/f1 Eq. B2.3-5 = -2.029 k= 4 + 2*(1-Y)^3 + 2*(1-Y) Eq. B2.3-4 = 65.64 flat depth=w= yl+y3 = 3.885 in w/t= 64.75 1=lambda= [1.052/(k)^0.5] * (w/t) * (fl/E)A0.5 = [1.052/(65.64)^0.5] * 3.885 * (50.29/29500)^0.5 = 0.347 < 0.673 be=w= 3.885 in b2= be/2 bl= be(3-Y) = 1.94 in = 0.773 bl+b2= 2.713 in > 1.2825 in, Web is fully effective Determine effect of cold working on steel yield point (Fya) per section A7.2 Fya= C*Fyc + (1-C)*Fy (EQ A7.2-1) Lcomer=Lc= (p/2) * (r + t/2) 0.141 in C= 2*Lc/(Lf+2*Lc) Lflange-top=Lf= 1.510 in = 0.157 in m= 0.192*(Fu/Fy) - 0.068 (EQ A7.2-4) = 0.1590 Bc= 3.69*(Fu/Fy) - 0.819*(Fu/Fy)^2 - 1.79 = 1.427 since fu/Fv= 1.18 < 1.2 and r/t= 1 < 7 OK then Fyc= Bc * Fy/(R/t)^m (EQ A7.2-2) = 78.485 ksi Thus, Fya-top= 58.70 ksi (tension stress at top) Fya-bottom= Fya*Ycg/(depth -Ycg) = 113.94 ksi (tension stress at bottom) Check allowable tension stress for bottom flange Lflange-bot=Lfb= Lbottom - 2*r*-2*t = 2.510 in Cbottom=Cb= 2*Lc/(Lfb+2*Lc) = 0.101 Fy-bottom=Fyb= Cb*Fyc + (1-Cb)*Fyf = 57.37 ksi Fya= (Fya-top)*(Fyb/Fya-bottom) = 29.56 ksi if F= 0.95 Then F*Mn=F*Fya*Sx= Eq. B2.1-4 Eq. B2.1-1 OK Eq B2.3-2 (EQ A7.2-3) 4.125 in 2.75 in 1.75 in Beam= SpaceRak SB416C 4.125 in x 0.06 in Ix= Sx= Ycg= t= Bend Radius=r= FY=FW= Fu=Fuv= E_ top flange=b= bottom flange= 22.52 in -k 1.817 in^4 0.802 inA3 2.723 in 0.060 in 0.060 in 55.00 ksi 65.00 ksi 29500 ksi 1.750 in 2.750 in Web depth= 4.?1c Fy °n fl(comp) yl= Ycg-t-r= 2.603 in y2= depth-Ycg= 1.403 in y3= y2 -t -r= 1.283 in �•1 c t; Structural Engineering & Design Inc. 1815 Wright Ave La Verne, CA 91750 Tel: 909.596.1351 Fax: 909.596.7186 By: S.P. Project: INDUSTRIAL REVOLUTION Project #: LV -041218-8 BEAM Configuration: TYPE 2 SELECTIVE RACK 144 IN BAY S/R RMI Section 5.2, PT II Section Beam= SpaceRak SB416C 4.125 in x 0.06 in Ix=Ib= 1.817 in^4 Sx= 0.802 in^3 t= 0.060 in E= 29500 ksi Fy=Fyv= 55 ksi F= 250.0 Fu=Fuv= 65 ksi L= 144 in Fya= 58.7 ksi Beam Level= 1 P=Product Load= 2,500 Ib/pair D=Dead Load= 75 Ib/pair 1. Check Bending Stress Allowable Loads Mcenter=F*Mn= W*L*W*Rm/8 W=LRFD Load Factor= 1.2*D + 1.4*P+1.4*(0.125)*P RMI ZZ item 8 FOR DL=2"/o of PL, W= 1.599 Rm= 1 - [(2*F*L)/(6*E*Ib + 3*F*L)] 1 - (2*250*144 in)/[(6*29500 ksi*1.817 in^3)+(3*250*144 in)] = 0.832 if F= 0.95 Then F*Mn=F*Fya*Sx= 44.72 in -k Thus, allowable load per beam pair=W= F*Mn*8*(# of beams)/(L*Rm*W) = 44.72 in -k * 8 * 2/(144in * 0.832 * 1.599) = 3,735 Ib/pair allowable load based on bending stress Mend= W*L*(1-Rm)/8 = (3735 Ib/2) * 144 in * (1-0.832)/8 = 5,647 in -Ib = 3,780 in -Ib @ 3735 Ib max allowable load @ 2500 Ib imposed product load 2. Check Deflection Stress Allowable Loads 4.125 in 2.75 in 1.75 in 1IIII11I111IIIIIIIIIIIIIII1I11111UIII1111III111111II1 Dmax= Dss*Rd Rd= 1 - (4*F*L)/(5*F*L + 10*E*Ib) = 1 - (4*250*144 in)/[(5*250*144 in)+(10*29500 ksi*1.817 in^4)] = 0.799 in if Dmax= L/180 Based on L/180 Deflection Criteria and Dss= 5*W*L^3/(384*E*Ib) L/180= 5*W*L^3*Rd/(384*E*Ib*# of beams) solving for W yields, W= 384*E*I*2/(180*5*L^2*Rd) = 384*1.817 in^4*2/[180*5*(144 in)^2*0.799) = 2,761 Ib/pair allowable load based on deflection limits Thus, based on the least capacity of item 1 and 2 above: Allowable Deflection= L/180 = 0.800 in Deflection at imposed Load= 0.724 in Allowable load= 2,761 ib/pair Imposed Product Load= 2,500 lb/pair !Beam Stress= 0.91 Beam at Leve/ 1 Structural Engineering & Design Inc. By: S.P. 1815 Wright Ave I a Verne_ CA 91750 TeL 909.596.1351 Fax: 909.596 7186 Project: INDUSTRIAL REVOLUTION Project #: LV -041218-8 4 Pin Beam to Column Connection TYPE 2 SELECTIVE RACK 144 IN BAY S/R 1 ne beam end moments snown nereln snow the result of the maximum Induced fixed end monents torm seismic + static toads and the code mandated minimum value of 1.5%(DL+PL) Mconn max= (Mseismic + Mend-fixity)*0.70*Rho = 26,538 in -Ib Load at level 1 Connector Type= 4 Pin Shear Capacity of Pin P1 O P2 P3 P4 2"TYP 6" 12" 12" rho= 1.0000 Pin Diam= 0.44 in Fy= 55,000 psi Ashear= (0.438 in)^2 * Pi/4 = 0.1507 inA2 Pshear= 0.4 * Fy * Ashear = 0.4 * 55000 psi * 0.1507inA2 = 3,315 Ib Bearing Capacity of Pin Ecol= 0.105 in Omega= 2.22 Fu= 65,000 psi a= 2.22 Pbearing= alpha * Fu * diam * tcol/Omega = 2.22 * 65000 psi * 0.438 in * 0.105 in/2.22 = 2,989 Ib < 3315 Ib Moment Capacity of Bracket Edge Distance=E= 1.00 in Pin Spacing= 2.0 in Fy= 55,000 psi c= P1+P2+P3+P4 tdip= 0.18 in = P1+P1*(4.576.5")+P1*(2.5"/6.5")+P1*(0.5"/6.5") = 2.154 * P1 Mcap= Sdip * Fbending = 0.127 inA3 * 0.66 * Fy = 4,610 in -lb Pdip= Mcap/(2.154 * d) = 4610.1 in-Ib/(2.154 * 0.5 in) = 4,281 Ib C*d= Mcap = 2.154 Thus, P1= 2,989 Ib Mconn-allow= [P1*6.5"+P1*(4.5"/6.5")*4.5" +P1*(2.5"/6.5")2.5" +P1*(0.5"/6.5")*0.5] = 2989 LB*[6.5"+(4.5"/6.5")*4.5"+(2.576.572.5"+(0.576.570.5"] = 31,729 in -Ib > Mconn max, OK Sdip= 0.127 in^3 d= E/2 = 0.50 in INDUSTRIAL REVOLUTION -TYPE 2 SGLxIs Page of 16 4/17/2018 Structural Engineering & Design Inc. 1815 Wright Ave La Verne. CA 91750 Tel: 909.596.1351 Fax: 909.596.7186 By: S.P. Project: INDUSTRIAL REVOLUTION Project #: LV -041218-8 Transverse Brace Configuration: TYPE 2 SELECTIVE RACK 144 IN BAY S/R Section Properties Diagonal Member= Sperack 1-1/2x1-1/4x14ga Area= 0.292 inA2 r min= 0.430 in Fy= 55,000 psi K= 1.0 Sk= 1.92 Frame Dimensions Horizontal Member= Sperack 1-1/2x1-1/4x14ga Area= 0.292 in^2 r min= 0.430 in Fy= 55,000 psi K= 1.0 I .500 In Bottom Panel Height=H= 48.0 in Frame Depth=D= 44.0 in Column Width=B= 3.0 in Diagonal Member Clear Depth=D-B*2= 38.0 in X Brace= NO rho= 1.00 0 I Load Case 6: : (if 1 ais s) .85f0.14Sds)*8*P f [0.7*rho*EJ<= .1.0, ASD Method Vtransverse= 1,872 Ib Vb=Vtransr*0.7*rho= 1872 Ib * 0.7 * 1 = 1,310 Ib Ldiag= [(D-B*2)^2 + (H-6")^2]^1/2 = 56.6 in Pmax= V*(Ldiag/D) * 0.75 = 1,2641b axial load on diagonal brace member Pn= AREA*Fn = 0.292 in^2 * 16812 psi = 4,909 Ib Pallow= Pn/S2 = 4909 Ib /1.92 = 2,5571b Pn/Pallow= Horizontal brace 0.49 <= 1.0 OK (kl/r)= (k * Ldiag)/r min = (1 x 56.6 in /0.43 in ) = 131.6 in Fe= pi^2*E/(Id/r)^2 = 16,812 psi Since Fe<Fy/2, Fn= Fe = 16,812 psi Typical Panel Configuration Vb=Vtransr*0.7*rho= 1,310 Ib (kl/r)= (k * Lhoriz)/r min = (1 x 44 in) /0.43 in = 102.3 in Since Fe>Fy/2, Fn=Fy*(1-fy/4fe) = 27,817 psi Pn/Pallow= 0.31 <= 1.0 OK Fe= pi^2*E/(kl/r)^2 = 27,821 psi Pn= AREA*Fn = 0.292inA2*27817 psi = 8,123 Ib Fy/2= 27,500 psi Pallow= Pn/12c = 8123 Ib /1.92 = 4,231 Ib INDUSTRIAL REVOLUTION -TYPE 2 SGL.xls Page 16 of 16, 4/ 1 7/201 8 Structural Engineering & Design Inc. 1815 Wright Ave La Verne, CA 91750 Tel: 909.596.1351 Fax: 909.596.7186 By: S.P. Project: INDUSTRIAL REVOLUTION Project#: LV -041218-8 Single Row Frame Overturning Configuration: TYPE 2 SELECTIVE RACK 144 IN BAY S/R Loads Critical Load case(s): 1) RMI Sec 2.2, item 7: (0.9-0.2Sds)D + (0.9-0.20Sds)*B*Papp - E*rho Vtrans=V=E=Qe= 1,872 Ib DEAD LOAD PER UPRIGHT=D= 225 Ib PRODUCT LOAD PER UPRIGHT=P= 7,500 Ib Papp=P*0.67= 5,025 Ib Wst LC1=Wst1=(0.70986*D + 0.70986*Papp*1)= 3,726 Ib Product Load Top Level, Ptop= 2,500 Ib DL/LvI= 75 Ib Seismic Ovt based on E, E(R*hi)= 425,021 in -Ib height/depth ratio= 5.6 in Sds= 0.9507 (0.9-0.2Sds)= 0.7099 (0.9-0.2Sds)= 0.7099 B 1:0000 rho= 1.0000 Frame Depth=Df= 44.0 in Htop-Iv1=H= 246.0 in # Levels= 3 # Anchors/Base= 4 hq= 72.0 in hp A Tt v H Df SIDE ELEVATION A) Fully Loaded Rack h=H+hp/2= 282.0 in Load case 1: Movt= E(Fi*hi)*E*rho = 425,021 in -Ib Mst= Wst1 * Df/2 = 3726 Ib * 44 in/2 = 81,972 in -Ib T= (Movl-Mst)/Df = (425021 in -Ib - 81972 in-Ib)/44 in = 7,797 Ib Net uplift per Column I Net Seismic Uplift= 7,797 Ib B) Top Level Loaded Only Load case 1: 0 V1=Vtop= Cs * Ip * Ptop >= 350 Ib for I -1/D >6.0 = 0.3566 * 2500 Ib = 8921b Vleff= 892 Ib Critical Level= 3 V2=VDL= Cs*Ip*D Cs*Ip= 0.3566 = 80 Ib Mst= (0.70986*D + 0.70986*Ptop*1) * 44 in/2 = 42,556 in -Ib Movt= [V1*h + V2 * H/2]*0.7*rho = 182,890 in -Ib T= (Movt Mst)/Df = (182890 in -Ib - 42556 in-Ib)/44 in = 3,189 Ib Net Uplift per Column • I Net Seismic Uplift= 3,189 Ib Anchor Check (4) 0.5" x 3.25" Embed POWER SDII anchor(s) per base plate. Special inspection is required per ESR 2502. Pullout Capacity=Tcap= 1,850 Ib L.A. City Jurisdiction? NO Shear Capacity=Vcap= 2,150 Ib Phi= 1 (1949 Ib/1850 Ib)^1 + (234 Ib/2150 Ib)^1 = (797 lb/1850 1b)^1 + (111 Ib/2150 Ib)^1 Fully Loaded: Top Level Loaded: Tcap*Phi= 1,850 Ib Vcap*Phi= 2,150 Ib 1.16 <= L2 OK 0.48 <= L2 OK INDUSTRIAL REVOLUTION -TYPE 2 SGL.xls Page t j of ((F, 4/ 17/20 18 Structural Engineering & Design Inc. 1815 Wright Ave La Verne CA 91750 Tel: 909.596.1351 Fax: 909.596.7186 By: S.P. Project: INDUSTRIAL REVOLUTION Project #: LV -041218-8 Base Plate Configuration: TYPE 2 SELECTIVE RACK 144 IN BAY S/R Section Baseplate= 8x8x3/8 Eff Width=W = 8.00 in a = 3.00 in Eff Depth=D = 8.00 in Anchor c.c. =2*a=d = 6.00 in Column Width=b = 3.00 in N=# Anchor/Base= 4 Column Depth=dc = 4.63 in Fy = 36,000 psi L = 2.50 in Plate Thickness=t = 0.375 in Down Aisle Loads Load Case 5: : (1+0.105*Sds)D + 0.75*[(1.4+0.14Sds)*B*P + 0.75*[0.7*rho*E]<= 1.0, ASD Method Downaisle Elevation COLUMN DL= 113 Ib COLUMN PL= 3,750 Ib Base Moment= 8,000 in -Ib 1+0.105*Sds= 1.0998 1.4+0.14Sds= 1.5331 B= 07004'. Axial stress=fa = P/A = P/(D*W) = 49 psi Moment Stress=fb = M/S = 6*Mb/[(D*B^2] = 49.2 psi Moment Stress=fbl = fb-fb2 = 18.5 psi M3 = (1/2)*fb2*L*(2/3)*L = (1/3)*fb2*L^2 = 64 in -Ib S -plate = (1)(tA2)/6 = 0.023 in^3/in fb/Fb = Mtotal/[(S-plate)(Fb)] 0.43 OK Tanchor = (Mb-(PLapp*0.75*0.46)(a))/[(d)*N/2] = -582 Ib No Tension Axial=P= 1.0998235 * 112.5 Ib + 0.75 * (1.533098 * 0.7 * 3750 Ib) = 3,1421b Mb= Base Moment*0.75*0.7*rho = 8000 in -Ib * 0.75*0.7*rho = 4,200 in -lb Axial Load P = 3,142 Ib Mbase=Mb = 4,200 in -Ib Cross Aisle Loads M1= wL^2/2= fa*L^2/2 = 153 in -Ib Moment Stress=fb2 = 2 * fb * L/W = 30.8 psi M2= fb1*L^2)/2 = 58 in -Ib Mtotal = M1+M2+M3 = 275 in-Ib/in Fb = 0.75*Fy = 27,000 psi Fp= 0.7*Fc = 2,800 psi OK Tallow= 1,850 Ib cn alkart case RMI Sec 21,item a.•(1i0115dr)DL (1f01a.5wss)00.75+a11.75<_ LO, ASD Method OK Check uplift load on Baseplate Effc Effe Pstatic= 3,142 Ib Movt*0.75*0.7*rho= 223,136 in -Ib Frame Depth= 44.0 in P=Pstatic+Pseismic= 8,213 Ib b =Column Depth= 4.63 in L =Base Plate Depth -Col Depth= 2.50 in fa = P/A = P/(D*W) = 128 psi Sbase/in = (1)(tA2)/6 = 0.023 in^3/in fb/Fb = M/[(S-plate)(Fb)] 0.63 OK Pseismic= Movt/Frame Depth = 5,071 Ib M= wL^2/2= fa*L^2/2 = 401 in-Ib/in Fbase = 0.75*Fy = 27,000 psi Check uplift forces on baseplate with 2 or more anchors per RMI 7.2.2. n the base plate configuration consists or two anchor bolts located on either side f the column and a net uplift force exists, the minimum base plate thickness hall be determined based on a design bending moment in the plate equal o the uplift force on one anchor times 1/2 the distance from e centerline of the anchor to the nearest edge of the rack column" Ta Elevation Uplift per Column= 7,796 Ib Qty Anchor per BP= 4 Net Tension per anchor=Ta= 1,949 Ib c= 2.50 in Mu=Moment on Baseplate due to uplift= Ta*c/2 = 2,436 in -Ib Splate= 0.188 in^3 fb Fb *0.75= 0.361 OK INDUSTRIAL REVOLUTION -TYPE 2 SGL.xls Page ) z of [ (, 4/17/2018 Structural Engineering & Design Inc. 1815 Wright Ave La Verne. CA 91750 Tel: 909.596.1351 Fax 909.596.7186 By: S.P. Project: INDUSTRIAL REVOLUTION Project #: LV -041218-8 Slab on Grade Configuration: TYPE 2 SELECTIVE RACK 144 IN BAY S/R 1111211111111 III IIJIII II I I Ill III IIIIII11II11111111IIIIli i11111111IIII I Iillllilllll II1I1111I11111 x -►I ; 14- L SLAB ELEVATION Base Plate Effec. Baseplate width=B= 8.00 in Effec. Baseplate Depth=D= 8.00 in Column Loads Baseplate Plan View width=a= 3.00 in depth=b= 4.63 in midway dist face of column to edge of plate=c= 5.50 in midway dist face of column to edge of plate=e= 6.31 in Concrete fc= 4,000 psi tslab=t= 6.0 in teff= 6.0 in pin 0.6 Soil fsoil= 750 psf Movt= 297,515 in -Ib Frame depth= 44.0 in Sds= 0.951 0.2*Sds= 0.190 t100 R=B/D= 1.000 Fc^0.5= 63.20 psi DEAD LOAD=D= 113 Ib per column unfactored ASD load PRODUCT LOAD=P= 3,750 Ib per column unfactored ASD load Papp= 2,513 Ib per column P-seismic=E= (Movt/Frame depth) = 6,761 Ib per column unfactored Limit State load ........................ B= 0.7000 rho 1,0,,:, Sds= 0.9507 1.2 + 0.2*Sds= 1.3901 0.9 - 0.20Sds= 0.7099 Puncture Load Case 1) (1.2+0.2Sds)D + (1.2+0.2Sds)*B*P+ rho*E RMI SEC 2.2 EQTN 5 = 1.39014*113Ib+1.39014*0.7*3750Ib+1*6761Ib = 10,567 Ib Load Case 2) (0.9-0.2Sds)D + (0.9-0.2Sds)*B*Papp + rho*E RMI SEC 2.2 EQTN 7 = 0.70986 * 113 Ib + 0.70986 * 0.7 * 2512.5 Ib + 1 * 6761 Ib = 8,090 Ib Load Case 3) 1.2*D + 1.4*P RMI SEC 2.2 EQTN 1,2 = 1.2*113 Ib + 1.4*3750 Ib = 5,385 Ib Load Case 4) 1.2*D + 1.0*P + 1.0E = 10,647 lb Effective Column Load=Pu= 10,647 Ib per column ACI 318-1158- 921, E*, 9-5 Apunct= Fpunctl= Fpunct2= Fpunct eff= Slab Bending [(c+t)+(e+t)]*2*t 285.75 in^2 [(4/3 + 8/(3*13)l * ? *(Fc^0.5) 151.7 psi 2.66 * 7. * (Fc^0.5) 100.9 psi 100.9 psi fv/Fv= Pu/(Apunct*Fpunct) = 0.369 < 1 OK Pse=DL+PL+E= 10,647 Ib Asoil= (Pse*144)/(fsoil) = 2,044 in^2 x= (L -y)12 = 13.7 in Fb= 5*(phi)*(fc)^0.5 = 189.74 psi L= (Asoil)^0.5 = 45.21 in M= w*x^2/2 = (fsoil*x^2)/(144*2) = 485.9 in -Ib y= (c*e)^0.5 + 2*t = 17.9 in S -slab= 1*teff^2/6 = 6.0 in^3 fb/Fb= M/(S-slab*Fb) = 0.427 < 1, OK INDUSTRIAL REVOLUTION -TYPE 2 SGL.xis Page 13 of l 6, 4/ 17/2018 Structural Engineering & Design Inc. 1815 Wright Ave La Verne. CA 91750 Tel: 909.596.1351 Fax: 909.596.7186 By: S.P. Project: INDUSTRIAL REVOLUTION Project #: LV -041218-8 Configuration & Summary: TYPE 1 SELECTIVE RACK 96 IN BAY S/R 84.E 264" 84 78" -4- 96" -1- 264' 60" 54" 54,. 36" 36" 44..E **RACY COLUMN RE4C77ONS ASO LOADS AXIAL DL= 1131b AXIAL LL= 3,600/b SEISMIC AXIAL Ps=f/- 9,0421b BASE MOMENT= 8,000int-/b Seismic Cnteria # Bm Lvls Frame Depth Frame Height # Diagonals Beam Length Frame Type Ss=1.426, Fa=1 3 44 in 264.0 in 5 96 in Single Row Component Description STRESS Column Fy=55 ksi SPCRK FH-30/3x3x12ga P=2475 Ib, M=23678 in -Ib 0.55-0K Column & Backer To Level 1 SPCRK FH30-FS-8/3x3x12ga/3x1-5/8x14ga p= 3713 Ib, M= 41691 in -Ib 0.65-0K Beam Fy=55 ksi SpaceRak SB376C 3.75 in x 0.06 in Lu=96 in Capacity: 4177 Ib/pr 0.57 -OK Beam Connector Fy=55 ksi Lvl 1: 4 pin OK I Mconn=23403 in -Ib Mcap=31729 in -Ib 0.74 -OK Brace -Horizontal Fy=55 ksi Sperack 1-1/2x1-1/4x14ga 0.3 -OK Brace -Diagonal Fy=55 ksi Sperack 1-1/2x1-1/4x14ga 0.48 -OK Base Plate Fy=36 ksi 8x8x3/8 1 Fixity= 8000 in -Ib 0.6 -OK Anchor 4 per Base 0.5" x 3.25" Embed POWER SDII ESR 2502 Inspection Reqd (Net Seismic Uplift=7248 Ib) 0.858 -OK Slab & Soil 6" thk x 4000 psi slab on grade. 750 psf Soil Bearing Pressure 0.39 -OK Level Load** Per Level Beam Spcg Brace Story Force Transv Story Force Longit. Column Axial Column Moment Conn. Moment Beam Connector 1 2,400 Ib 78.0 in 36.0 in 289 Ib 216 Ib 3,713 lb 41,691 "# 23,403 "# 4 pin OK 2 3 2,400 Ib 84.0 in 2,400 Ib 84.0 in 36.0 in 54.0 in 54.0 in 60.0 in 600 Ib 911 Ib 448 Ib 680 Ib 2,475 lb 23,678 "# 13,808 "# 4 pin OK 1,238 Ib 14,276 "# 5,521 "# 4 pin OK ** Load defined as product weight per pair of beams Notes Total: 1,800 lb 1,343 lb INDUSTRIAL REVOLUTION -TYPE I SGL.xls Page )4 of 16 4/17/2018 Structural Engineering & Design Inc. 1815 Wright Ave La Verne. CA 91750 Tel: 909.596.1351 Fax: 909.596.7186 By. S.P. Project: INDUSTRIAL REVOLUTION Project#: LV -041218-8 Configuration & Summary: TYPE 1 SELECTIVE RACK 96 IN BAY D/R 1 84" 264" 84" 78" 96" 264' 60" 54" 54,E 36" 35' 44' -t 44" -+ **RACK COLUMN REACTIONS ASD LOADS AXL4L DL= 1131b AXIAL LL= 3,600/b SEISMICAXL4L Ps=f/- 9,042/, BASEMOMENT= 8,000 in -Ib Seismic Criteria # Bm Lvls Frame Depth Frame Height # Diagonals Beam Length Frame Type Ss=1.426, Fa=1 3 44 in 264.0 in 5 96 in Double Row Component Description STRESS Column Fy=55 ksi SPCRK FH-30/3x3x12ga P=2475 Ib, M=23678 in -Ib 0.55 -OK Column & Backer To Level 1 SPCRK FH30-FS-8/3x3x129a/3x1-5/8x14ga p= 3713 Ib, M= 41691 in -Ib 0.65-0K Beam Fy=55 ksi SpaceRak SB376C 3.75 in x 0.06 in Lu=96 in Capacity: 4177 Ib/pr 0.57 -OK Beam Connector Fy=55 ksi LvI 1: 4 pin OK I Mconn=23403 in -lb Mcap=31729 in -Ib 0.74 -OK Brace -Horizontal Fy=55 ksi Sperack 1-1/2x1-1/4x14ga 0.3 -OK Brace -Diagonal Fy=55 ksi Sperack 1-1/2x1-1/4x14ga 0.48 -OK Base Plate Fy=36 ksi 8x8x3/8 1 Fixity= 8000 in -Ib 0.6 -OK Anchor 2 per Base 0.5" x 3.25" Embed POWER SDII ESR 2502 Inspection Reqd (Net Seismic Uplift=4536 lb) 0.975 -OK Slab & Soil 6" thk x 4000 psi slab on grade. 750 psf Soil Bearing Pressure 0.39-0K Level Load** Per Level Beam Spcg Brace Story Force Transv Story Force Longit. Column Axial Column Moment Conn. Moment Beam Connector 1 2,400 Ib 78.0 in 36.0 in 289 Ib 216 Ib 1_711111 41 Aa1 "ie lq 4n/ "4 a ..,., nv 2 2,400 Ib 84.0 in 3 2,400 Ib 84.0 in 36.0 in 54.0 in 54.0 in 60.0 in 600 Ib 911 Ib 4481b 680 Ib 2,475 Ib 1,238 Ib 23,678 "# 13,808 "# 4 pin OK 14,276 "# 5,521 "# 4 pin OK ** Load defined as product weight per pair of beams Notes Total: 1,800 Ib 1,343 Ib PROVIDE (3) H , R/S INDUSTRIAL REVOLUTION -TYPE 1 .xls Page (r of (6, 4/17/2018 Structural Engineering & Design Inc. 1815 Wright Ave La Verne. CA 91750 Tel: 909.596.1351 Fax: 909.596.7186 By: S.P. Project: INDUSTRIAL REVOLUTION Project #: LV -041218-8 Configuration & Summary: TYPE 2 SELECTIVE RACK 144 IN BAY D/R 264" 84' 78" 144" -1- 264' 60" 54. 54" 36" y 44" x' 44" "RAO( COLUMN RE4 CT7ONS ASD LOADS AXIAL DL= 113/b AXIAL LL= 4,050/b SEISMIC AXIAL Ps=#/- 10,1271b BASE MOMENT= 8,000 in -Ib Seismic Criteria # Bm Lvls Frame Depth Frame Height # Diagonals Beam Length Frame Type Ss=1.426, Fa=1 3 44 in 264.0 in 5 144 in Double Row Component Description STRESS Column Fy=55 ksi SPCRK FH-30/3x3x12ga P=2775 Ib, M=26498 in -Ib 0.63 -OK Column & Backer To Level 1 SPCRK FH30-FS-8/3x3x12ga/3x1-5/8x14ga p= 4163 Ib, M= 47611 in -Ib 0.74 -OK Beam Fy=55 ksi SpaceRak SB416C 4.125 in x 0.06 in Lu=144 in Capacity: 2761 Ib/pr 0.98 -OK Beam Connector Fy=55 ksi Lvl 1: 4 pin OK Mconn=28795 in -lb Mcap=31729 in -Ib 0.91 -OK Brace -Horizontal Fy=55 ksi Sperack 1-1/2x1-1/4x14ga 0.33 -OK Brace -Diagonal Fy=55 ksi Sperack 1-1/2x1-1/4x14ga 0.53 -OK Base Plate Fy=36 ksi 8x8x3/8 ' Fixity= 8000 in -Ib 0.67 -OK Anchor 4 per Base 0.5" x 3.25" Embed POWER SDII ESR 2502 Inspection Reqd (Net Seismic Uplift=5082 Ib) 0.667 -OK Slab & Soil 6" thk x 4000 psi slab on grade. 750 psf Soil Bearing Pressure 0.47-0K Level Load** Per Level Beam Spcg Brace Story Force Transv Story Force Longit. Column Axial Column Moment Conn. Moment Beam Connector 1 2,700 Ib 78.0 in 36.0 in 324 Ib 241 Ib 4,163 ib 47,611 "# 28,795 "# 4 pin OK 2 2,700 Ib 3 2,700 ib 84.0 in 84.0 in 36.0 in 54.0 in 54.0 in 60.0 in 672 Ib 501 Ib 2,775 Ib 26,498 "# 17,724 "# 4 pin OK 1,020 Ib 761 Ib 1,388 Ib 15,977 "# 8,449 "# 4 pin OK ** Load defined as product weight per pair of beams Total: 2,016 Ib 1,503 Ib Notes ILOAD/COMPONENTS OK FOR INT TUNNEL BAYS 144 IN WIDE. BEAM WITH FULL WELD. PROVIDE 4 H D R/S. INDUSTRIAL REVOLUTION -TYPE 2 DBL.xIs Page .2 6, of %G, 4/17/2018 May 15, 2018 f1 City of Tukwila Department of Community Development CHRIS LING 9800 40TH AVE S SEATTLE, WA 98118 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D18-0113 INDUSTRIAL REVOLUTION - 5835 SEGALE PARK C DR Dear CHRIS LING, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: FIRE DEPARTMENT: Al Metzler at 206-971-8718 if you have questions regarding these comments. • 1) Please provide a detailed description of the types of commodities to be stored on the racks. 2) Please provide the total storage height and the ceiling height. 3) Smoke vents may be required. Please submit a drawing showing locations of existing/proposed smoke vents. 4) What is the sprinkler density of the existing ceiling fire sprinkler system? 5) What is the temperature rating of the existing fire sprinklers? Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. Sincerely, Bill Rambo Permit Technician File No. D18-0113 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP \ / PERMIT NUMBER: D18-0113 DATE: PROJECT NAME: INDUSTRIAL REVOLUTION SITE ADDRESS: 5835 SEGALE PARK C DR Original Plan Submittal Revision # 05/18/18 before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: Building Division Public Works n Av' �z�t--r8 Fire Prevention Structural n Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) REVIEWER'S INITIALS: DATE: 05/22/18 Structural Review Required DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required DUE DATE: 06/19/18 ri Approved with Conditions ❑ Denied n (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 l PERMIT COORD CORY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0113 DATE: 04/23/18 PROJECT NAME: INDUSTRIAL REVOLUTION SITE ADDRESS: 5835 SEGALE PARK C DR X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: elA !w'ic Building Division Public Works n itw1 S�H� Firc Prevention Structural Planning Division riPermit Coordinator n PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 04/24/18 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 05/22/18 Approved ❑ Approved with Conditions (corrections entered in Reviews) (ie: Zoning Issues) Corrections Required Denied Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire Ping 0 PW ❑ Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 5A).1)7/ Plan Check/Permit Number: 1L, L 8 — 0 113 ❑ Response to Incomplete Letter # 113 Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: Project Address: Contact Person: Summary of Revision: /n/A,STri A -c, oLvt - - 3r SEEiRL6 i e i. .1?r. S: k C GA.I.s 1._,;—s Phone Number: .2 4.71. )W 313 RECEIVED CITY OF TUKWILA MAY 18 2018 PERMIT CENTEP /. G+..,.p.4 /4.471,s, engai k.: -f , ,,k,v;i S' , Aleit S , TN6� �--�s Ftofs P ?. 6E114;41 i+C'r,AT 36 , C/e'v /left j— 3a r -r TJf 04- tar.04,-I- a5' 3. M' _Syw)IK C /#L ted— c V. Senn kc Oe...c1 — 7Sel EAS C5is--\ S T�Mpr,.F+.tt �,.+► S J� �wb;&,s IQs /441r ° /I x Si74 (4 /-ft /6 ,'(T 3t' per P., Fri oF- 6%e t PAr ` Sheet Number(s): 447i97,W7o-.Ac. "Cloud" or highlight all areas of revision including date orevilon Received at the City of Tukwila Permit Center by: Entered in TRAKiT on C-1 W:\Permit Center\Templates\Forms\Revision Submittal Form.doc Revised: August 2015 ENGINEERED PRODUCTS, A PAPE -c0 lyl, Home Espanol Contact Safety & Health Claims & Insurance kill)Washington State Department of Labor & Industries Search L&I A -Z Index Help Page 1 of 2 My LI Workplace Rights Trades & Licensing ENGINEERED PRODUCTS, A PAPE CO Owner or tradesperson Principals SALMAN, DAVID EROL, PRESIDENT WETLE, CHRISTOPHER THOMAS, VICE PRESIDENT CARNEAU, CORY SCOTT, VICE PRESIDENT JORGENSEN, LANCE RICHARD, VICE PRESIDENT SMYTHE, SETH LARRY, SECRETARY PAPE, RANDALL JORDAN, SECRETARY CT CORP SYSTEMS, AGENT RIECKE, ROBERT J, SECRETARY (End: 02/04/2013) SAYLOR, THOMAS H, TREASURER (End: 02/04/2013) HOLLINGSHEAD, DANNY W, VICE PRESIDENT (End: 02/12/2013) PAPE, MARY SUSAN, VICE PRESIDENT (End: 02/13/2017) RIECKE, ROBERT JOHN, VICE PRESIDENT (End: 02/13/2017) Doing business as ENGINEERED PRODUCTS, A PAPE CO WA UBI No. 602 684 203 9800 40th AVE SO SEATTLE, WA 98118 206-394-3300 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. ENGINPC931CO Effective — expiration 02/20/2007— 02/20/2019 Bond FIDELITY & DEPOSIT CO OF MD Bond account no. 08748464 $12,000.00 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602684203&LIC=ENGINPC931 CO&SAW= 5/29/2018 ENGINEERED PRODUCTS, A PAPE CO Received by L&I 02/16/2007 Insurance .............. National Union Fire Ins of PA Policy no. g15180113 Effective date 02/13/2007 Expiration date Until Canceled $1,000,000.00 Received by L&I Effective date 02/27/2018 03/01/2018 Expiration date 03/01/2019 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 586,069-04 Doing business as ENGINEERED PRODUCTS A PAPE COM Estimated workers reported Quarter 1 of Year 2018 "51 to 75 Workers" L&I account contact T2 / DALE RIUTTA (360)902-4834 - Email: RIUD235@Ini.wa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602684203&LIC=ENGINPC931 CO&SAW= 5/29/2018 PLAN NORTH 3 11 r 11 c: 44"x144" 44"x96" 44"x144" 44"x144" 44"x144" 44"x144" 44"x144" 44"x144" 44"x96" 44"x144" 44"x144" 44"x96" sr 1 44"x144" 44"x144" 44"x96" • 44"x144" 44"x144 44"x96" 44"x144" 44"x144" 44"x144" 1 44"x144" 44"x144" 44"x144" It 44"x144" 44"x144" 44"x144" 44"x144" 44"x144" 44"x144" 44"x144" 44"x144" 44"x144" 44"x144" 44"x144" 44"x144" ie 44"x144" 44"x144" 44"x144" 44"x144" 44"x144" 44"x144" 44"x144" 44"x144" 44"x144" 44"x144" 44"x144" 44"x144" 44"x144" 44"x144" 44"x144" 44"x144" it 44"x144" 44"x144" 44"x144" 44"x144" 44"x144" 44"x144" 44"x144" 44"x144" 44"x144" 44"x144" 44"x144" 44"x144" 44"x144" DLA\ VHW SCALE: ?" = 1'-0" 'SEPARATE PERMIT REQUIRED FOR: CYiii1ochanical EKlectrical El/Plumbing L4as Piping City of Tukwila B.UILDING DIVISION FILE COPY P ra No. X16-0113 Plan review approval is subject to errors and omissions. t.pproval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field - .,,y : - (cond' ' • s acknowledged: By: Date: ?i. P City of Tukwila BUILDING DIVISION h Fe -B•-1 REVISIONS I 1----Nc...) z ---.halt ctla igesIle. rade to the scope _ Di i -, « ,;s.dill require a new plan submittal a td may i ,, ude additional plan review fee a' REVIEWED F• OR. CODE COMPLIANCE APPROVED MA? 25M ;8 S City of Tukwila" BUILDING DIVISION RECEIVED CITY OF TUKWIL APR 23 2018 PERMIT CENTE 04/19/2018 THE P.E. CERTIFICATION PROVIDED HEREIN PERTAINS TO THE SHELVING COMPONENTS ONLY. ALL OTHER COMPONENTS ARE OUTSIDE THE SCOPE OF THIS CERTIFICATION. h cs c\1 o7 10 CO F— 0 9883 40TH AVENUE Fax: 206-575-6688 206-394-3300 a) 0 a_ w tIzi A "A DRAWINGS PREPARED FOR LL cci -0 5835 Segale Park Dr C Tukwila, WA 98188 DRAWN BY: CLING SCALE: STATED DATE: 3.7.2018 JOB NO: 114931 CHECKED BY: CL SHEET NO./ OF 2 SHEETS 3 2 5/8" -3/8" 3 116" 3/16" COLUMN 3 1/8" NOTES: BACKER REQ'D UP TO 84" ELEV. r 1 2' 3" X1-5/8" SECTION BEAM VIEW A -A NOTES: USE @ ALL COLUMN/BASE LOCATIONS TYP. DESCRIPTION NOTES: ATTACH WITH (4) 3/8"� GR. 5 BOLTS, (2) @ EACH END A— NOTES: (3) HD R/S @ TYPE 1 (4) HD R/S @ TYPE 2, TUNNEL BAY @ BACK TO BACK UNITS. BASE PLATE: 8" x 8" MATERIAL STEEL YIELD 3/8" THK ASTM A36, Fy=36,000 PSI DESCRIPTION COLUMN: FH30/FH2O BKR. MATERIAL 12/14 GAGE THK. DESCRIPTION BRACING: HORIZ. & DIAG. MATERIAL STEEL YIELD ASTM A570, Fy=55,000 PSI 14 GAGE THK. DESCRIPTION HD ROW SPACER STEEL YIELD ASTM A570, Fy=55,000 PSI NOTES: USE @ ALL BRACE LOCATIONS TYP. MATERIAL 14 GAGE STEEL YIELD ASTM A36, Fy = 36,000 PSI 1 3/8" SAFETY CLIP NOTES: USE @ ALL BEAM TO COLUMN CONNECTION LOCATIONS TYP. DESCRIPTION MATERIAL GENERAL PROJECT NOTES 1. DESIGNED PER REQUIREMENTS OF THE 2015 IBC, ASCE 7-10 AND THE 2012 RMI RACK DESIGN MANUAL 2. SEISMIC CRITERIA Ss = 1.426, S1 = 0.532, Fa = 1.00, Fv = 1.50, fp = 1.0 (NO PUBLIC ACCESS), Sds = 0.951, Sd1 = 0.532, OCCUPANCY CATAG. II, SITE CLASS D, SEISMIC DESIGN CATAG. D 3. STORAGE CAPACITY: TYPE 1 = 2400# PER LEVEL TYP. TYPE 2 S/R = 2500# PER LEVEL TYP. TYPE 2 D/R, TUNNEL = 2700# PER LEVEL TYP. 4. ANCHORS HILT! KWIK BOLT TZ ESR #1917 OR POWER SD2 ESR#2502, OR ICC & ENGINEER APPROVED EQUAL. 1/2" X 3-1/4" MIN. EMBEDED. (2) ANCHOR PER BASE PLATE @ D/R UNITS (4) ANCHOR PER BASE PLATE @ S/R UNITS 5. PERIODIC SPECIAL INSPECTION IS REQUIRED DURING ANCHOR INSTALLATION. 6. EXISTING S.O.G. CONCRETE THICKNESS & COMPRESSIVE STRENGTH, 6" x 4000 PSI 7. SOIL BEARING PRESSURE 750 PSF @ GRADE OR BETTER 8. ALL RACK INSTALLATIONS AND RACKS MANUFACTURED IN CONFORMITY WITH THIS STANDARD SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS A PERMANENT PLAQUE EACH NOT LESS THAN 50 SQUARE CLEAR, LEGIBLE PRINT. 9. ALL BOLTS GR. 5 OR BETTER. INSTALL TO SNUG TIGHT FIT WITH ALL PLYS IN FIAT CONTACT 10. ALL WELDING PERFORMED IN THE SHOP OF AN APPROVED FABRICATOR BY AWS CERTIFIED WELDERS USING E70XX ELECTRODE OR BETTER. FIELD WELDS, IF ANY, SHALL BE PROVIDED UNDER THE SUPERVISION OF A LICENSED DEPUTY INSPECTOR. 11. THE CLEAR SPACE BELOW SPRINKLERS SHALL BE A MIN. OF 18" BETWEEN TOP OF THE STORAGE AND THE CEILING SPRINKLER DEFLECTOR. 12. SHIMS MAY BE USED UNDER THE BASE PLATE TO MAINTAIN THE PLUMBNESS OF THE STORAGE RACK. 13. THE SHIMS SHALL BE MADE OF A MATERIAL THAT MEETS OR EXCEED THE DESIGN BEARING STRENGTH (LRFD) OR ALLOWABLE BEARING STRENGTH (ASD) OF THE FLOOR. THE SHIM SIZE AND LOCATION UNDER THE BASE PLATE SHALL BE EQUAL TO OR GREATER THAN THE REQUIRED BASE PLATE SIZE AND LOCATION. SHIMS SHALL BE INTERLOCKED OR WELDED TOGETHER IN A FASHION THAT CAN TRANSFER ALL THE SHEAR FORCES AT THE BASE. BENDING IN THE ANCHOR ASSOCIATED WITH SHIMS OR GROUT UNDER THE BASE PLATE SHALL BE CONSIDERED IN THE DESIGN OF THE ANCHOR BOLTS. 14. THE PRODUCT SHOWN ON THE DETAILS HEREIN IS ASSUMED TO BE IN GOOD, UNDAMAGED CONDITION. THE PRODUCT MUST BE FREE OF ANY DAMAGE AND/OR FABRICATION DEFICIENCIES OR IRREGULARITIES. IT IS THE RESPONSIBILITY OF THE OWNER, USER, PRODUCT PROVIDER AND/OR INSTALLER OF THE COMPONENTS TO NOTIFY SED, INC IN WRITING, OF ANY DAMAGE, DEFICIENCIES OR IRREGULARITIES. 15. IT IS THE RESPONSIBILITY OF THE OWNER AND/OR USER OF THE COMPONENTS SHOWN HEREIN TO NOTIFY SED, INC OF ANY DAMAGE OR DEFICIENCIES IN THE SYSTEM DURING USE. THIS INCLUDES SUCH OCCURRENCES SUCH AS IMPACT DAMAGE TO THE COMPONENTS FROM FORKLIFT OR HEAVY MACHINERY, IMPACT FROM DROPPED LOADS ON THE SYSTEM, DAMAGE TO SYSTEMS BY IMPROPER USE OR INSTALLATION, ETC. THE USER OF THE PRODUCT MUST NOTIFY SED, INC IN WRITING SHOULD ANY DAMAGE OR DEFICIENCY OCCUR TO THE PRODUCT SHOWN HEREIN. IT IS THE RESPONSIBILITY OF THE OWNER AND/OR USER TO MAINTAIN THE SAFETY AND PROPER USE OF THE STORAGE PRODUCT SHOWN HEREIN. 16. IT IS THE RESPONSIBILITY OF THE OWNER/USER OF THE STORAGE SYSTEM SHOWN HEREIN TO REPAIR OR REPLACE ANY COMPONENT THAT IS DAMAGED OR OTHERWISE DEFICIENT. 17. THE OWNER SHALL MAINTAIN THE STRUCTURAL INTEGRITY OF THE RACK SYSTEM BY ASSURING PROPER OPERATIONAL, HOUSE KEEPING AND MAINTENANCE PROCEDURES, BUT NOT LIMITED TO THE FOLLOWING: a. PROHIBIT ANY OVER LOADING OF ANY PALLET POSITIONS AND OF OVERALL RACK SYSTEMS. b. REGULARLY INSPECT FOR DAMAGE. IF DAMAGE IS FOUND, IMMEDIATELY UNLOAD THE AFFECTED AREA AND REPLACE OR REPAIR ANY DAMAGED COLUMNS, BEAMS, OR OTHER STRUCTURAL COMPONENTS. c. REQUIRE ALL PALLETS TO BE MAINTAINED IN GOOD, SAFE, OPERATING CONDITION. d. ENSURE THAT PALLETS ARE PROPERLY PLACED ONTO PALLET LOAD SUPPORT MEMBERS IN PROPERLY STACKED AND STABLE POSITION. e. REQUIRE THAT ALL GOODS STORED ON EACH PALLET TO BE PROPERLY STACKED AND STABLE. f. PROHIBIT DOUBLE STACKING OF ANY PALLET POSITION, INCLUDING THE TOP MOST POSITION, UNLESS THE RACK SYSTEM IS SPECIFICALLY DESIGNED FOR SUCH LOADING. g. THE OWNER AND/OR USER OF THE RACK SYSTEM MUST PROVIDE MEASURES TO MITIGATE DAMAGE TO THE STORAGE RACK BY USE OF IMPACT PROTECTIVE DEVICES IN AREAS WHERE FORKLIFT AND/OR HEAVY MACHINERY ARE IN USE. a 4 -PIN CONNECTOR 7 GAGE STEEL YIELD ASTM A570, Fy=55,000 PSI DESCRIPTION MATERIAL STEEL YIELD 3-3/4" BEAM (SB376C) 16 GAGE THK. NOTES: USE @ TYPE 2, TUNNEL BEAM LOCATIONS TYP. DESCRIPTION 4-1/8" BEAM (SB#416C) MATERIAL 16 GAGE ASTM A570, Fy=55,000 PSI STEEL YIELD ASTM A570, Fy=55,000 PSI 2 TYPE 1 SELECTVE RACK 6" 44" 1101' TYPE 2 SELECTVE RACK 144" TYPE TUNNEL BAY RACK 144" 44" 4" \ , 84" 84" 84" FRONT VIEW r REVIEWED FOR CODE COMPLIANCE APPROVED n „ MAY 252018 City of Tukwila BUILDING DIVISION 84" 84" F.F. 54" 54" 264" 84" 264" 84" 3 1/4" MIN. EMBED. 54" 54" 1 /2" RECEIVED CITY OF TUKWILA 84" 84" 3 SIDE VIEW NOTE: SEE NOTE #4 ABOVE FOR ANCHOR SPECS. PERMIT CENTER APR 23 2018 DESCRIPTION FRONT VIEW FRONT VIEW SIDE VIEW STORAGE RACK ELEVATIONS SIZE POWER SD2 ANCHOR 1/2"0 X 3-1/4" MIN. EMBED. ESR# 4/19/2018 ENGINEERED PRODUCTS JOB NO. z 0 2) J O w CC EE U) 2) z DATE 04/13/18 5835 SEGALE PARK DR. STE. C co co rn H SPACE RACK LL Cl) F 1815 WRIGHT AVE. LV -041218-8 SHEET NO. SED 1 OF 1