Loading...
HomeMy WebLinkAboutPermit D18-0134 - BOULEVARD AT SOUTH STATION APARTMENT - BUILDING G SIDING AND WINDOW FRAMINGBOULEVARD AT SOUTH STATION APTS -BLDG G 4706 SOUTHCENTER BLVD BLDG 6 D18-0134 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 2223049003 Permit Number: 4706 SOUTHCENTER BLVD BLDG G Issue Date: Permit Expires On: BOULEVARD AT SOUTH STATION APTS - BLDG G 018-0134 5/29/2018 11/25/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: MG ACRES APARTMENTS LP 10505 SORRENTO VALLEY RD , SAN DIEGO, WA, 92121 ISAIAH PARK 4913 70 AVE W , UNIVERSITY PLACE, WA, 98467 STEADFAST CONSTRUCTION INC. 1057 ANDOVER PK E , TUKWILA, WA, 98188 STEADCI98417 Expiration Date: 4/30/2019 Phone: (253) 579-5505 Phone: (253) 805-7725 MG PROPERTIES GROUP 10505 SORRENTO VALLEY RD - SUITE 300, SAN DIEGO, CA, 92121 DESCRIPTION OF WORK: REMOVE & HAUL AWAY SELECTED AREAS OF EXISTING SIDING. INSTALL (1) LAYER OF FORTIFIED SUPER JUMBO TEX 60 MINUTE WRB & FLASH AROUND WINDOWS AND OTHER OPENINGS WITH SELF ADHERED MEMBRANE AND METAL HEAD FLASHING. INSTALL PRE -PRIMED CEDAR CHANNEL SIDING, LIKE FOR LIKE, WHERE REMOVED. APPROXIMATELY 594 SQ FT. Project Valuation: $9,057.00 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $506.61 Occupancy per IBC: R-2 Water District: 125 Sewer District: VALLEY VIEW,TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA C ties Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Lua la) Date:\ -2 '( 4 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating con . ucti • or therformance of work. I am authorized to sign and obtain this development p- i d agree . th- co ditio attached to this permit. Signature: / Date: Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: All wood to remain in placed concrete shall be treated wood. v 1 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0409 FRAMING 0601 WALL INSULATION 0413 WALL SHEATHING/SHEAR CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. Project No. Date Application Accepted: .. -2-1 0 Date Application Expires: 1 1 - --t Cp (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION J 1 King Co Assessor's Tax No.: 2 22 3 0 7 6100 3 Site Address: 7D6 5ov6ticetde, €Iv t_ G�/v �r�/ll��, • - Yid Suite Number: 6 Floor: /VA • Tenant Name: kdjev� 4/4 4,7 ca -I f 5 . New Tenant: 0 Yes ( No PROPERTY OWNER Name: /7/6 A��,e5 ,,,,,,Q Name: ///4 104wt _ hCS al ,,,,,y,° Address:/0CoS Sorl'eto if1t 1.0►..1,ite 3x City: �na State: t Zip: gm, 1 CONTACT PERSON - person receiving all project communication Name: /s,,D� Address: e 7.04t, (/j City: UNiteers." Race. State: (j Zip: q .. Phone: Jr3_57.1-�$ 5Fax: ?�( '3� 65S 2 - Email: /SQGc i.7 , Pori esieetAs7 • 6014/ GENERAL CONTRACTOR INFORMATION Company Name: 5� ► . (SI JnC, Address: /ir„ v3 .e'h five. W City: f%tve 1/ O/ estate: /Am._ Zip:gp"? Phone: .206-83g,6SS0 Fax: 206-83g'-653-2_ Contr Reg No.: `. j-yjq q.f xp Date: ZOO q Tukwila Business License No.: HAApplications\Forms-Applications on Line&2012 Applications'Peimit Application Revised - 2-7-12.docx Revised: February 2012 bh ARCHITECT OF RECORD Company Name: Architect Name: Address: City: State: - Zip: Phone: Fax: Email: ENGINEER OF RECORD Name: /7/6 A��,e5 ,,,,,,Q Company Name: i/a Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater peerr�(.7 RCW 19.27.095) Name: /7/6 A��,e5 ,,,,,,Q Address:0505 1/0ir veil, .6f /ie. e,. ;le Sod City:�CLiI 1/40ke9a State: Zip:�-/2J Page 1 of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ "/ 05? Existing Building Valuation: $ jeM Describe the scope of work (please provide detailed information): /eard ve- /Jelec* f a-feet.0 CriC-6 s < /r1-12:// (1) l er- Ati bSl '�er- L70470 7`era:-i,lidA t' & f FlasI, Anivx.d kl/c14 01�s ocrtI o ><G�e, m ei in tn,5.c ("IA cegi 'dt.�.e.tedSU" b M metal /lead 4,' . /145-4111 ri // -Tnom'"- ike u/S55rei' Ie Will there be new rack storage? ❑ ....Yes If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. HA1Applications'Forms-Applications On Line\2012 Applicatiotu\Permit Application Revised - 2-7-12.docx Revised: February2012 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1" Floor rd Floor 3rd Floor Floors thru Basement il..../ Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. HA1Applications'Forms-Applications On Line\2012 Applicatiotu\Permit Application Revised - 2-7-12.docx Revised: February2012 bh Page 2 of 4 f PUBLIC WORKS PERMIT INFORMATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila ❑ ...Water District #125 ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ .. Sewer Use Certificate ❑...Highline ❑ ...Valley View 0...Renton ❑ ...Sewer Availability Provided 0... Renton 0... Seattle 1 Septic System: ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ .. Civil Plans (Maximum Paper Size — 22" x 34") 0 .. Technical Information Report (Storm Drainage) 0 .. Bond 0...Insurance ❑... Easement(s) ❑. ❑. Proposed Activities (mark boxes that apply): ❑ .. Right-of-way Use - Nonprofit for less than 72 hours ❑ .. Right-of-way Use - No Disturbance 0 .. Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way 0 0 .. Total Cut cubic yards D .. Total Fill cubic yards 0 .. Sanitary Side Sewer 0 .. Cap or Remove Utilities ❑ .. Frontage Improvements 0 .. Traffic Control 0 .. Backflow Prevention - Fire Protection Irrigation Domestic Water 0. ❑. 0. 0. Geotechnical Report .. Maintenance Agreement(s) ❑ .. Traffic Impact Analysis ❑ .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) 0...Right-of-way Use - Profit for less than 72 hours ❑._. Right-of-way Use —Potential Disturbance 0... Work in Flood Zone 0...Storm Drainage .. Abandon Septic Tank .. Curb Cut .. Pavement Cut .. Looped Fire Line 0 .. Permanent Water Meter Size (1) 0 .. Temporary Water Meter Size (1) ❑ .. Water Only Meter Size ❑ .. Sewer Main Extension Public 0 ❑ .. Water Main Extension Public ❑ 0...Grease Interceptor ❑... Channelization 9...Trench Excavation 0...Utility Undergrounding WO # (2) " WO # (3) WO # (2) " WO # (3) WO # ❑ .. Deduct Water Meter Size Private ❑ Private 0 " WO# " WO# FINANCE INFORMATION Fire Line Size at Property Line ❑ .. Water ❑ .. Sewer ❑ .. Sewage Treatment Monthly Service Billing to: Name: Mailing Address: Number of Public Fire Hydrant(s) Day Telephone: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H: ApplicationsYForms-Applications On r.ine12012 Applications\Petmit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Signature: Date: 9/BUILDING OW ' 0' AUTHOR ' ED N /�Q'� �` `� Print Name: /44.7•A ��1I- Day Telephone: 0-g -574:7 Mailing Address: 4 f/3 7.044 Ale. 0 .litefsi* P'" "r IN l �96 try State Zip HAApplicntionsTorms•Applications On Line 2012 Applicationa\Fennit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 4 of 4 Cash Register Recei City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY, PAID PermitTRAK $7,498.85 D18-0128 Address: 4732 SOUTHCENTER BLVD BLDG A Apn: 2223049003 $500.02 DEVELOPMENT $476.42 PERMIT FEE R000.322.100.00.00 0.00 $471.92 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $23.60 TECHNOLOGY FEE R000.322.900.04.00 0.00 $23.60 D18-0129 Address: 4726 SOUTHCENTER BLVD BLDG B Apn: 2223049003 $991.73 DEVELOPMENT $944.72 PERMIT FEE R000.322.100.00.00 0.00 $940.22 WASHINGTON STATE SURCHARGE 8640.237.114 0.00 $4.50 TECHNOLOGY FEE $47.01 TECHNOLOGY FEE R000.322.900.04.00 0.00 $47.01 D18-0130 Address: 4722 SOUTHCENTER BLVD BLDG C Apn: 2223049003 $745.87 DEVELOPMENT $710.57 PERMIT FEE R000.322.100.00.00 0.00 $706.07 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $35.30 TECHNOLOGY FEE R000.322.900.04.00 0.00 $35.30 D18-0131 Address: 4718 SOUTHCENTER BLVD BLDG D Apn: 2223049003 $500.02 DEVELOPMENT $476.42 PERMIT FEE R000.322.100.00.00 0.00 $471.92 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $23.60 TECHNOLOGY FEE R000.322.900.04.00 0.00 $23.60 D18-0132 Address: 4714 SOUTHCENTER BLVD BLDG E Apn: 2223049003 $745.87 DEVELOPMENT $710.57 PERMIT FEE R000.322.100.00.00 0.00 $706.07 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $35.30 TECHNOLOGY FEE R000.322.900.04.00 0.00 $35.30 Date Paid: Tuesday, May 29, 2018 Paid By: STEADFAST CONSTRUCTION INC. Pay Method: CHECK 25422 Printed: Tuesday, May 29, 2018 1:23 PM 1 of 2 SYSTEMS DESCRIPTIONS z PermitTRAK ACCOUNT QUANTITY PAID $7,498.85 D18-0133 Address: 4710 SOUTHCENTER BLVD BLDG F Apn: 2223049003 $374.08 DEVELOPMENT $356.48 PERMIT FEE R000.322.100.00.00 0.00 $351.98 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $17.60 TECHNOLOGY FEE R000.322.900.04.00 0.00 $17.60 D18-0134 Address: 4706 SOUTHCENTER BLVD BLDG G Apn: 2223049003 $311.11 DEVELOPMENT $296.51 PERMIT FEE R000.322.100.00.00 0.00 $292.01 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $14.60 TECHNOLOGY FEE R000.322.900.04.00 0.00 $14.60 D18-0135 Address: 4530 SOUTHCENTER BLVD BLDG H Apn: 2223049003 $1,318.63 DEVELOPMENT $1,256.05 PERMIT FEE R000.322.100.00.00 0.00 $1,251.55 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $62.58 TECHNOLOGY FEE R000.322.900.04.00 0.00 $62.58 D18-0136 Address 4520 SOUTHCENTER BLVD BLDG 1 Apn: 2223049003 $1,216.47 DEVELOPMENT $1,158.76 PERMIT FEE R000.322.100.00.00 0.00 $1,154.26 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $57.71 TECHNOLOGY FEE R000.322.900.04.00 0.00 $57.71 D18-0137 Address: 4510 SOUTHCENTER BLVD BLDG J Apn: 2223049003 $795.05 DEVELOPMENT $757.40 PERMIT FEE R000.322.100.00.00 0.00 $752.90 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $37.65 TECHNOLOGY FEE R000.322.900.04.00 0.00 $37.65 c. TOTAL FEES PAID BY RECEIPT: R14600 $7,498.85 �� r �_ Date Paid: Tuesday, May 29, 2018 Paid By: STEADFAST CONSTRUCTION INC. Pay Method: CHECK 25422 Printed: Tuesday, May 29, 2018 1:23 PM 2 of 2 SYSTEMS as Register Recei City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK - PAID. $4,752.73 D18-0128 Address: 4732 SOUTHCENTER BLVD BLDG A Apn: 2223049003 $315.95 Credit Card Fee $9.20 Credit Card Fee R000.369.908.00.00 0.00 $9.20 DEVELOPMENT $306.75 PLAN CHECK FEE R000.345.830.00.00 0.00 $306.75 D18-0129 Address: 4726 SOUTHCENTER BLVD BLDG B Apn: 2223049003 $629.47 Credit Card Fee $18.33 Credit Card Fee R000.369.908.00.00 0.00 $18.33 DEVELOPMENT $611.14 PLAN CHECK FEE R000.345.830.00.00 0.00 $611.14 D18-0130 Address: 4722 SOUTHCENTER BLVD BLDG C Apn: 2223049003 $472.72 Credit Card Fee $13.77 Credit Card Fee R000.369.908.00.00 0.00 $13.77 DEVELOPMENT $458.95 PLAN CHECK FEE R000.345.830.00.00 0.00 $458.95 D18-0131 Address: 4718 SOUTHCENTER BLVD BLDG D Apn: 2223049003 $315.95 Credit Card Fee $9.20 Credit Card Fee R000.369.908.00.00 0.00 $9.20 DEVELOPMENT $306.75 PLAN CHECK FEE R000.345.830.00.00 0.00 $306.75 D18-0132 Address: 4714 SOUTHCENTER BLVD BLDG E Apn: 2223049003 $472.72 Credit Card Fee $13.77 Credit Card Fee R000.369.908.00.00 0.00 $13.77 DEVELOPMENT $458.95 PLAN CHECK FEE R000.345.830.00.00 0.00 $458.95 D18-0133 Address: 4710 SOUTHCENTER BLVD BLDG F Apn: 2223049003 $235.65 Credit Card Fee $6.86 Credit Card Fee R000.369.908.00.00 0.00 $6.86 DEVELOPMENT $228.79 PLAN CHECK FEE 1 R000.345.830.00.00 I 0.00 $228.79 Date Paid: Wednesday, May 02, 2018 Paid By: ISAIAH PARK Pay Method: CREDIT CARD 02284G Printed: Wednesday, May 02, 2018 2:17 PM 1 of 2 JL SYSTEMS DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $4,752.73 D18-0134 Address: 4706 SOUTHCENTER BLVD BLDG G Apn: 2223049003 $195.50 Credit Card Fee $5.69 Credit Card Fee R000.369.908.00.00 0.00 $5.69 DEVELOPMENT $189.81 PLAN CHECK FEE R000.345.830.00.00 0.00 $189.81 D18-0135 Address: 4530 SOUTHCENTER BLVD BLDG H Apn: 2223049003 $837.92 Credit Card Fee $24.41 Credit Card Fee R000.369.908.00.00 0.00 $24.41 DEVELOPMENT $813.51 PLAN CHECK FEE R000.345.830.00.00 0.00 $813.51 D18-0136 Address: 4520 SOUTHCENTER BLVD BLDG I Apn: 2223049003 $772.78 Credit Card Fee $22.51 Credit Card Fee R000.369.908.00.00 0.00 $22.51 DEVELOPMENT $750.27 PLAN CHECK FEE R000.345.830.00.00 0.00 $750.27 D18-0137 Address: 4510 SOUTHCENTER BLVD BLDG J Apn: 2223049003 $504.07 Credit Card Fee $14.68 Credit Card Fee R000.369.908.00.00 0.00 $14.68 DEVELOPMENT $489.39 PLAN CHECK FEE I R000.345.830.00.00 0.00 I $489.39 TOTAL FEES PAID BY RECEIPT: : R14405 $4,752.73 Date Paid: Wednesday, May 02, 2018 Paid By: ISAIAH PARK Pay Method: CREDIT CARD 02284G Printed: Wednesday, May 02, 2018 2:17 PM 2 of 2 1 IMi gSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION P/13°-013 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: ,8jdt.0 3� R Type of Inspection: il .Calico//t& f- ,,11....Address: '/7t* .5"ovrr/601,17Rt/O, Date Called: (a m p.m. Special Instructions: 805. G Date Wanted: Z -Zit -18 Requester: Phone No: Approved per applicable codes. E1 Corrections required prior to approval. COMMENTS: 0K - am-,D/N6- 14ihl 9 -i -- Inspector: Date: 7 -2X-/5 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Dv$-oi3i1 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project:1.. C3Lytd Ack- 554,‘,4 -in S4Pcben Typeg Inspection: r�1 I%l t 1\) Co A4€1 -6tote-Gailta4 69,6 2 -D v - oY W ALL. Sc L�ec I Instructions: 6 7L% 5o Kce't T13 Lct xis,' Yom"' ` Date Wanted: � -20/o 4 - 1.,i...2.0/8, a.m. P.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. OMMENTS: FreveYi Inspector: j$6(2._ Date REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Btvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 D 1 s -b 131-1 Project: C o� S �5 4►to Type of I specti n: WAI .5h, tiAltetar __l 7141"45 Sa C Date Called: --� Sp ial I//nstruCctio_nfs,: ���,,(�,� Li7e '"..?:11)1--C9-3 6 Date Wanted:/_ a.m. L( ZDIEr Requester: Phone No: AE,Approved per applicable codes. pproved required prior to approval. CO MENTS: Inspector Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. ESTEAD FAST CONSTRUCTION INC IP5343 22 Mar 2018 MAILING: JOBSITE: ATTN: Rich Sorensen 10811 Southeast 239th Place Kent,Washington 98031 Phone: work:619-372-8214 E-mail: work:rsorensen@mgproperties.com Boulevard at South Station Apartments 4708 Southcenter Boulevard Tukwila,Washington 98188 We have inspected the property and hereby submit a bid provided all labor, materials, equipment, supplies and supervision to perform the work within the description of this document: A. Scope: Selected Siding Repairs and Replacement 1. Remove & haul away existing cedar channel siding at selected locations. 2. Install (1) layer of Fortifiber Super Jumbo -Tex 60 -minute weather resistive barrier. 3. Windows and other openings at the selected walls shall be flashed with self -adhered membrane on all four sides and metal head flashing. 4. Install new pre -primed cedar channel siding and exterior trim where removed from the selected walls. 5. All wood shall be pre -primed prior to install. 6. Caulk and seal all nail holes and seams/joints. 7. Remove & replace 28' linear feet of fascia at Locations #7 (building H) and #29 (Cabana). 8. Remove & replace damaged soffits at Locations #16 (building I), and #23, 25, 27 (building J). • Take all necessary precautions but not limited to safety devices to prevent any accidents. • Jobsite will be cleaned of all trash, debris, and excess material, etc. daily to the satisfaction of the Property Manager. RL4'i7k �.J FOR CODE CO. LANCE APMCVLD MAY 18 2318 of Tdkwila BUILD!NG DIVISION RECEIVEn CITY OF TUKWILA MAY 02 2018 PERMIT CENTER Lu z 0 11 O 0 cci 4) O Qac ''C• ON di ��O V10 0 O 4) 0,4\0 PERM T CENTER WINDOW FLASHING A GUIDE TO INSTALLATION METHOD "A" SELF ADHESIVE FLASHING The "Method A" installation guide is designed for integral flanged win- dow applications, where the window is installed before the weather resis- tive barrier is applied. Compliance with the building code and proper installation are critical in reducing potential water leakage points. Under adverse weather conditions, the installer may consider using "Method B" with mechanically attached flashing. Consideration should be given to preparing the substrate for best adhesion. For some substrates, a primer may be required. The following Fortifiber Building Systems Group® flexible window flashing products are acceptable for this method: • Moistop E -Z Seal® Self Adhesive Flashing 6, 9 and 12 inch x 75' rolls • FortiFlash® Waterproof Flashing 4, 6, 9, 12, 18 and 36 inch x 75' rolls • FortiFlash® Commercial Waterproof Flashing 6, 9, 12 and 18 inch x 75' rolls • FortiFlash® Butyl Waterproof Flashing 4, 6, 9 and 12 inch x 75' rolls • Moistop® Sealant (Exceeds AAMA Standards) THIS INSTALLATION GUIDE REFERENCES THE AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION PUBLICATION 2400-02. Head \ashing 0 Sill flashing R CITY OF KWLLA HAY 02 2018 We suggest you review Forti-Facts Technical sheet available at www.fortifiber.com. Or for further assistance, please call our technical hotline at (800) 773-4777. SILL FLASHING After cleaning surface press firmly into place with adhesive edge flush with top of rough opening. �ID Sill flashing length is RO width + (2x flashing width). CAS Sill flashing yr 0 When flashing sill with FortiFlash or FortiFlash Butyl ... Or partially pull release paper Staple... Cut the sill flashing the width of the rough opening + 2x the width of the flashing. Wipe the exterior sheathing or wall with a clean rag to ensure proper adhesion. Remove the release paper and press the sill flashing in place so that the top edge of the flash- ing's adhesive is level with the top edge of the rough opening. Once pressed in place, use a 'J" roller (or wallpaper seaming tool) to seal the flashing to the sheathing. Note: when using Forti- Flash or FortiFlash Butyl, partially remove the release paper or staple to allow for integration with weather -resistive barrier (la). Once the weather barrier has been tucked under the sill flashing, remove the remaining release paper and press firmly in place. PaRMifil d CET ER 2 INSTALL WINDOW 0 Window Apply continuous 3/s" inch -- bead of sealant on window flange , c Window flange Before installing the window, apply a continu- ous 3/8" bead of Moistop Sealant to the back- side (interior) of the mounting flange. Install the window according to the window manufactur- er's instructions. CONTINUED... CONTINUED FROM FRONT ... 3 JAMB FLASHING Jamb flashing length is RO height + (2x flashing width, minus 1 ). Align the flashing flush against the . window frame with the adhesive strip • covering the entire window flange. woo SILL JUNCTION 0 Place adhesive edge of flashing against window and fully cover window flange. / /// 0 1 Startjamb flashing even with bottom of sill flashing. i HEAD JUNCTION 0 Using the jamb flashing formula RO height + (2x flashing width, minus 1") will bring the jamb flashing within 7" of the top of the head flashing. tr See Step 4 for details on installing the head flashing. / Prior to installing the jamb flashing, wipe the window jamb flange and exterior walls with a clean rag to ensure proper adhesion. Cut the jamb flashing to the height of the rough opening + 2x the width of the flashing, minus 1" (see 3a and 3b). Remove the release paper and place the jamb flashing against the window flange and firmly press into place in a single direction to prevent voids. Once pressed in place, use a J" roller (or wallpaper tool) to seal the flashing to the window flange. Repeat this procedure for the other side of the window. 4 HEAD FLASHING Head flashing length is' RO width + (2x flashing width, plus 2"). Align the flashing flush against the window frame with the adhesive strip covering the entire window flange. • Start head flashing 1" beyond jamb flashing, Wipe the head flange, jamb flashing and sheathing with a clean rag. Cut the head flashing to twice the width of the rough opening + 2x the width of the flashing plus 2". Install the head flashing by pressing firmly in place in one direction to prevent voids. Call 1-800-773-4777 for Technical Assistance www.fortifiber.com Limitations: For optimum adhesion, Molstop E -Z Seal, Fortinash and FortiFlash Commercial flashings should be applied at temperatures between 40° F (4.4° C) and 120° F (48.9° C); FortiFlash Butyl may be applied at temperatures between 25° F (3.9° C) and 125° F (51.7° C). Be cautious about using FortiFlash where it can be exposed to temperatures above its Service Temperature such as hot climates or behind fiber cement and metal sidings that absorb a significant amount of heat. FortiFlash, FortiFlash Commercial and FortiFlash Butyl are the only Fortifiber flashing products that can be installed horizontally or at a slope of less than 60°. Where installed horizontally or with a slope of less than 60° do not use fasteners. Product should be covered as soon as possible. Inspect product to insure it is free of any protrusions or damage which may compromise its moisture -resistive properties. FortiFlash is not compatible with EPDM or flexible (plasticized) Polyvinyl Chloride (PVC) based products. FortiFlash and Molstop E -Z Seal are not compatible with some sealants. Consult with sealant manufacturer for compatibility information. Direct exposure of sealant to the adhesive side of FortiFlash or Moistop E -Z Seal can be detrimental if the amount of sealant exceeds what is specified above. Please follow these recommendations regarding location and amount of sealant to be used. Fortifiber strongly recommends against the practice of using a "knockdown bead of sealant," or "buttering the flange" with sealant, because this amount of sealant is excessive and unnecessary. OVERVIEW l To propedyintegratesli and jamb .flashing tuck ryw the weather resistive l ' barrier underneath. ' f Fortifiber: recommends the use ofa well integrated weather -resistive barrier with all of its flashing systems. This recommendation refers to the most common types of windows used (surface mounted). For other types of frames, special attention should be paid to the window manufacturer's instructions. 2F Fortifiber Building Systems Group. Protecting Your World from the Elements' NATIONAL SALES OFFICE - Fernley, NV (1016/15) INSTALLING JUMBO TEX° THIS GUIDE APPLIES TO ALL GRADES OF JUMBO TEX AND HYDRO TEXTM Fortifiber Building Systems Group® provides this guide to assist installers by demonstrating an efficient and effective method for installing Jumbo Tex and the Jumbo Tex hybrid product Hydro Tex in common residential and light commercial settings. The back of this document has details regarding integrating these products with window flashing. Compliance with the building code and proper installation are critical in reducing potential water leakage points. It is the responsibility of the architect or builder to ensure that these standards are met. This guide applies to the following: • Super Jumbo Tex 60 minute 40" x 240 and 324 sq. ft. rolls • Two -Ply Super Jumbo Tex 60 minute 40" x 162 sq. ft. rolls • Jumbo Tex 40" x 324 and 500 sq. ft. rolls • Two -Ply Jumbo Tex 40" x 162 and 250 sq. ft. rolls • Hydro Tex 40" x 162 sq. ft. rolls Imo.------ iEeel s NAY 02 2 1 INSTALLING JUMBO TEX Install Jumbo Tex directly to studs or over an approved exterior sheath- ing. (When using HydroTex, install black side out.) Starting at the bottom of one end of the wall, place the Jumbo Tex roll horizontally (overlap- ping the corner by a minimum of 6') and roll out the first course evenly, integrating with flashing at window and door openings. Place the membrane so that it is tight and flat. Apply enough fasteners to hold Jumbo Tex in place until the final wall cladding is installed. MLA 18 Fasten all comers 0 0 a The size of fasteners used and the spacing required is determined on the Job site. Apply enough fasteners to hold • Jumbo Tex in place until final - cladding is applied 0 Under normal conditions, attaching Jumbo Tex with a quality exterior grade staple is acceptable. A higher grade of galvanized fastener, or large headed galva- nized nail may be required in certain settings or weather conditions. It is the responsibility of the architect, builder, or foreman to decide the type of exterior grade fastener that will best suit the job at hand and how many of these fasteners are required. R a o o ° �o ° Begin roll ° ,p minimum of 6" away, II 4 from corner I _r - a 4 n o 0 _L MLA 18 Fasten all comers 0 0 a The size of fasteners used and the spacing required is determined on the Job site. Apply enough fasteners to hold • Jumbo Tex in place until final - cladding is applied 0 Under normal conditions, attaching Jumbo Tex with a quality exterior grade staple is acceptable. A higher grade of galvanized fastener, or large headed galva- nized nail may be required in certain settings or weather conditions. It is the responsibility of the architect, builder, or foreman to decide the type of exterior grade fastener that will best suit the job at hand and how many of these fasteners are required. R 3 SEAM OVERLAPS VERTICAL 6" minimum vertical overlap • At vertical seams, apply a minimum 6" vertical over- lap. When going around corners, make sure Jumbo Tex is pulled tightly and properly fastened. HORIZONTAL Any succeeding course should be placed horizon- tally over the lower course in a weather -board fash- ion with a minimum hori- zontal overlap of 2" (3" is recommended). 4 JUMBO TEX° AND WINDOWS Upper layers of lumbo Tex covers jamb flashing MOI Tuck Jumbo Tex under sill window flashing • When a layer of Jumbo Tex first crosses the path of any window, it needs to be properly integrated with the window sill and jamb flashing for quality moisture man- agement. To do this, tuck Jumbo Tex under the sill and jamb flashing as shown above. The layers above this point can butt into the window jamb. JUMBO TEX AND WINDOW FLASHING Windows, window flashings, and weather barriers must be properly integrated in order to form a comprehensive moisture control system. The windows shown in this guide follow the "High Performance Two -Step" method of win- dow flashing. A detailed guide for this method of flashing can be found at www.fortifiber.com. Also, you can find other detailed instructions on how to integrate weather barriers and window flashings at the Fortifiber web site. Listed below are some of the common settings that you'll encounter when installing Jumbo Tex. WHEN WEATHER -RESISTIVE BARRIER IS INSTALLED AFTER THE WINDOW Use one of the following guides that apply: Method A (self adhesive) Method B (mechanically attached) High Performance Two -Step WHEN WEATHER -RESISTIVE BARRIER IS INSTALLED BEFORE THE WINDOW Use the following guide: Method Al (self adhesive) WEATHER -RESISTIVE BARRIERS AND SPECIALTY WINDOWS Use one of the following guides that apply: Window and Door Flashing (Installing windows and doors with integral brick mold) Arched Window Flashing Recessed Window Flashing Fortifiber provides four grades of Jumbo Tex, the hybrid HydroTex and a complete line of window flashing products to meet all your moisture management needs. Call 1-800-773-4777 Nationwide for Technical Assistance or visit www.fortifiber.com Limitations: Product should be covered as soon as possible. Inspect product to insure it is free of any protrusions or damage which may detract from the weather -resistive barrier integrity. Holes, tears or punctures should be sealed with Moistop® Sealant or Fortifiber Sheathing Tape. This product is not recommended for horizontal, roof- ing or below grade applications. our Web site at riFortifiber Building Systems Group® Protecting Your World from the Elements® NATIONAL SALES OFFICE — Fernley, NV (09/11/15) 3,. recommended horizontal horizontal overlap -- p-----_ 2„ I required - horizontal overlap Any succeeding course should be placed horizon- tally over the lower course in a weather -board fash- ion with a minimum hori- zontal overlap of 2" (3" is recommended). 4 JUMBO TEX° AND WINDOWS Upper layers of lumbo Tex covers jamb flashing MOI Tuck Jumbo Tex under sill window flashing • When a layer of Jumbo Tex first crosses the path of any window, it needs to be properly integrated with the window sill and jamb flashing for quality moisture man- agement. To do this, tuck Jumbo Tex under the sill and jamb flashing as shown above. The layers above this point can butt into the window jamb. JUMBO TEX AND WINDOW FLASHING Windows, window flashings, and weather barriers must be properly integrated in order to form a comprehensive moisture control system. The windows shown in this guide follow the "High Performance Two -Step" method of win- dow flashing. A detailed guide for this method of flashing can be found at www.fortifiber.com. Also, you can find other detailed instructions on how to integrate weather barriers and window flashings at the Fortifiber web site. Listed below are some of the common settings that you'll encounter when installing Jumbo Tex. WHEN WEATHER -RESISTIVE BARRIER IS INSTALLED AFTER THE WINDOW Use one of the following guides that apply: Method A (self adhesive) Method B (mechanically attached) High Performance Two -Step WHEN WEATHER -RESISTIVE BARRIER IS INSTALLED BEFORE THE WINDOW Use the following guide: Method Al (self adhesive) WEATHER -RESISTIVE BARRIERS AND SPECIALTY WINDOWS Use one of the following guides that apply: Window and Door Flashing (Installing windows and doors with integral brick mold) Arched Window Flashing Recessed Window Flashing Fortifiber provides four grades of Jumbo Tex, the hybrid HydroTex and a complete line of window flashing products to meet all your moisture management needs. Call 1-800-773-4777 Nationwide for Technical Assistance or visit www.fortifiber.com Limitations: Product should be covered as soon as possible. Inspect product to insure it is free of any protrusions or damage which may detract from the weather -resistive barrier integrity. Holes, tears or punctures should be sealed with Moistop® Sealant or Fortifiber Sheathing Tape. This product is not recommended for horizontal, roof- ing or below grade applications. our Web site at riFortifiber Building Systems Group® Protecting Your World from the Elements® NATIONAL SALES OFFICE — Fernley, NV (09/11/15) Installing Lap or Channel Siding Installing Lap Siding Stud House wrap Exterior sheathing Expansion gap 118" for dry siding Nails must penetrate soli wood 1Y," Cedar siding up to 6" wide A) 6" and narrower lap siding Nails must penetrate solid wood 1 Y+" Lap siding can be installed horizontal y or vertic. y. For horizontal applications, start with the bottom course and work up with the channels pointing upwards. Allow a 1/8 inch expansion gap between pieces if the siding is air or kiln -dried. Do not nail through overlaps. For siding up to 6 inches wide, use one nail one inch up from the lap. Face nail with two nails per piece for 8 inches patterns and wider, keeping nails 2-1/2 to 3 inches apart to allow for dimensional movement without splitting. For vertical applications, siding should be nailed to horizontal blocking or furring strips. RECEIVE! CITY OF T JKWILA MAY 02 2018 PF,RiiiiIT CENTER SEPA:'1,",1L 11-1- 7)1./i5:::: 1702: "1\110crianicat EIectricI a:plumbing 'Peas Piping City of Tukwila BUILPI;G DIVISAC.)N FILE COPY Permit No. Plan review approval is subjact to orrcrs cnd cmicsions. Approval of construction documents does r ot the violation of any adopted code r ctininco. Receipt of approved Fie! op and wledgcd: PAIASEpl By: Date: City c Tu!:wila BUILDING DIVISION REVISIONS No chanaos shall be Made to thr, SCOOP of work vilithNit prior approval flt pi 0,fling r.:pvistc-1 re -771 •".,; ,• r r- • r MG Properties Group' i April 30, 2018 RE: Rehabilitative Construction Project — Boulevard at South Station (210 units) 4708 Southcenter Boulevard — Tukwila, WA 98188 To Whom It May Concern: The purpose of this correspondence is to confirm that planned reconstructive construction project at the above listed address will not total more than 5% of the assessed value of the building. Enclosed find recent Real Estate Excise Tax Affidavit showing a recent assessed value for the project at $ 33,400,000.00. The second enclosed document outlines the planned rehabilitative construction expenses for the subject property which total $ 301,926.00. Please contact me should there be any additional questions related to this issue. Thank you in advance for your time and consideration in this matter. I Marc Wing MG Properties Group Management Company f r BRE MG Boulevard at South Station 619.573.5486 J 10505 Sorrento Valley Road Suite 300 San Diego, California 92121 858.366.6500 858.526.0800 REVf2V =:J FC CODE CG:.I,:LlANCE AP RCV.D MAY 18 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MG Properties Group® MAY 02 2018 10505 Sorrento Valley Road Suite 300 San Diego, California 92121 www.mgproperties.com Marc Wing PERMIT CENTER 858.366.6548 619.573.5486 858.909.9084 mwing@mgproperties.com bl8O13'i Fnn,rhin ii�.r� thrauoh h,°ttrrrnmmunftws Depamne14 o) Revenue th'oshrlgton Store REAL ESTATE EXCISE TAX AFFIDAVIT This form tsyour receipt PLEASE TYPE OR PRINT CHAPTER 82.45 RCW - CHAPTER 458-6)A WAC. when THIS AFF/DAVIT WILL NOT BE ACCEPTED UNLESS ALL AREAS ON ALL PAGES ARE FULLY COMPLETEDstampcd by cashier (Sec hack of lair page for instructions? Q Check box If partial tilt, Indicate : soki. Ust percentage or ownership acquired next to each name. Noma MG Aces Apanmants L.P., a Ca1rom;a Irmaeo pa tents/I:p and BRE MG Boulevard of South Station LLC, a Delaware R'amc RIG Park Place Apartments LLC, a Detaoare iamted aabelt9 company nneted eaotaty company h(nhng Addms G0 MG Properties Group. 16505 Sorrento Volley Rd,. 6300 > M.ilmy Add,„ 345 Park Avenue c Cuy0Stnn2ip Now York. NY Cayrsuio21p San Aogo CA 92:21 Phone Nn- fmcludmg arca code) (858) 3684534 Send all propen£ tax rorreipondeare ie: k4 Same as Ruyer,fnntee Name 222304-9003-01 0 Moiling Address Levy Code: 2401 CI c.,y/s adc%Ltp ❑ Phone No. (including (Coacode) (212) 5815748 Liu all re 1 and penned property los panel amount numbers - check box if personal pmpsny Prone. No (inctudmg arca code/ Sager .dares, of prop<rry 4708 Southcenler Blvd., Tukwila, WA 98188 ❑ Lin assessed valuers) 22,543 000,00 This pronto) is located in ❑ unincorporated. County OR st0m:n tilt or _Tukwila C] Chuck boo /forty of the ustnt parcels ore b<ir.g Ocgrc4meO from •norhar parcel. am pan of a baunlny line adjustment or parcels Fong merged Legal derail -Hien of property It moa optics is needed. you our auach a wpnaa shred m cash page 00101 /(fdavi)J SEE ATTACHED LEGAL DESCRIPTION • 6(6 r' Select Land Use Code(s),V 4•"- List all personal property (tangible and intangible) included in selling 13 price. enter any additional codes: (See back of last page for instructions) YES N(7 (i Was the seller receiving a property tax exemption or dsdaral win 0 choptcs 84 36, 84.37, a 8438 RCW (nonprofit organization, senior �L!eitian, Cr odisabled reason, Iv:exvwtser with limited inconter YES NO ❑ (H ❑ 13 Is this property designated as forint band par chapter 8433 RCW" Is dos poverty elaaifod as anent we (ups spar., farm and agriwhsesL or urnter) lane! Ter chapter 84.34 ROW? Ls taus property retching special 0el0ui4)3 as historialµtax, esty RT claps 8426 RCW' If any Novas are yrs, complete as ins -imam' below. (I) N(TTICEOF CY '11NIJANCE (FOREST LAND OR CURRE'ST USE) NEW OWNER(S): To continue the current designation as forest land or ciassificanon as current use (open space, farm and agracultaro, or umber) land. you must sign on (3) below. The county assessor must then determine lithe land transferred continues to qualify and will indicate by signing below. If the land no longer qualifies or you do not wish to continue the designation or clusifialson, it will be mtnaved and the compcnsaung or additional Laces will Ise due and payable by the seller or transferor at the lime of sale. (RCW 84.33.140 or RCW 04.34.108). Prior to sigtrg (3) below, you ;nay contact your bast county asx-5)1)r for nsure information. 'flies lend 0 docs ❑ deco not qualify for continuance. O OD DEPUTY ASSESSOR DATE (2) NOTICE OF COMPLIANCE (HISTORIC PROPERTY) NEW OWNER(S): To continue special valuation as historic propen), sign (3) below. lithe new mem r(s) does not wish to continue. all additional tae calculated pursuant to chapter 84.26 RCW, shall be due and payable by the seller or transferor at the time of sale (3) OWNER(S) SIGNATURE PIUNT NAME If claiming an exemption, list WAC number and reason for 0xem9110,0• WAC No (Section/Subsection) Reason for exemption Type of Document Grant Orae Dais of Document (dross Selling Price S 'Personal Property {deduct) S Exemption Claimed (deductl S Taxable Selling Price 5 Excise Tax : Stam S Local 5 'Delinquent )merest: State 5 Local S •Delinquent Penalty 5 Subtotal S 33 400,000.00 63,000.00 0.0 00 426,713.60 166,685.00 0.00 0.00 0.00 593,398.60 'State Technology Fen S 5 00 "Affidavit Preccssntg Pee 5 Total Due i 5934���� A MINISI UM OF 110.00 Is DUE: ins ff:r:(3) A`;Dr(1I (v OF �TUK UV LA •00E INSTRUCTIONS 1 CERTIFY UNDER PENALTY OF PERJURY THAT THE FOREGOING 10 TRUF AND CORRECT. Signature of Grantor or Grantor's Agent Name (punt) Date & city of signing: PLEASE SEE ATTACHED Signature of Grantee or Grantee's Agent Nome &print) Dec & city of signing: tAY022018 REMY CENTER Perjury: Perjury is a class C fck ny s.hich is punishable by n090100rnc01 In Use state eoneeuonal institution for a rnaxirnum tart of not mote than five years. or by a fine in en amount fixed by the court of not more Ilan five dxwsand do'lata (55,04100). or by both imprisonment and fine (RCA 9A.20020 (I C)1. REV 84 0091. (0n2,15) THIS SPACE - TREASURER'S USE ONLY COUNTY TREASURER Boulevard at South Station Bldg # of Units Value/Unit Bldg Value Value of Work % of Value J 12 $ 159,000.00 $ 1,908,000.00 $ 33,212.00 1.74% I 16 $ 159,000.00 $ 2,544,000.00 $ 63,405.00 2.49% H 12 $ 159,000.00 $ 1,908,000.00 $ 42,270.00 2.22% G 26 $ 159,000.00 $ 4,134,000,00 $ 9,057.00 0.22% F 14 $ 159,000.00 $ 2,226,000.00 $ 12,077.00 0.54% E 38 $ 159,000.00 $ 6,042,000.00 $ 30,193.00 0.50% D 14 $ 159,000.00 $ 2,226,000.00 $ 18,115.00 0.81% C 38 $ 159,000.00 $ 6,042,000.00 $ 30,193.00 0.50% B 26 $ 159,000.00 $ 4,134,000.00 $ 45,289.00 1.10% A 14 $ 159,000.00 $ 2,226,000.00 $ 18,115.00 0.81% Totals 210 $ 33,390,000.00 $ 301,926.00 CITY OF TW(N LA CLAY 02 2018 PERMIT CENTER f \ \ 'PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0134 DATE: 05/02/18 PROJECT NAME: BOULEVARD AT SOUTH STATION APTS - BLDG G SITE ADDRESS: 4706 SOUTHCENTER BLVD X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: A-- kWc —OAc� Building Division U4\ AWA- Public Works tTATS31S Fire Prevention Structural Plaf�nin ivision 1'6;t1 Permit Coordinator 11, PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 05/03/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required n Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 05/31/18 n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping ❑ PW 0 Staff Initials: 12/18/2013 STEADFAST CONSTRUCTION INo, si Washington State Department of Labor & Industries Home Espanol Contact Safety & Health Claims & Insurance Page 1 of 3 Search L&I A -Z Index Help My L&I Workplace Rights Trades & Licensing STEADFAST CONSTRUCTION INC Owner or tradesperson Principals PARK, YOUNG SIK, PRESIDENT PARK, ISAIAH, VICE PRESIDENT CHAMBERS, NINA, VICE PRESIDENT (End: 08/21/2002) Doing business as STEADFAST CONSTRUCTION INC WA UBI No. 602 032 300 4913 70TH AVE W UNIVERSITY PLACE, WA 98467 206-838-6550 PIERCE County Business type Corporation License Verify the contractors active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. STEADCI984J7 Effective — expiration 04/27/2002— 04/30/2019 Bond Lexon Ins Co $12,000.00 Bond account no. 9812818 Received by L&I Effective date 04/12/2012 05/12/2012 Expiration date Until Canceled Insurance United Specialty Insurance Com Policy no. ATN-SF1710939 $1,000,000.00 Received by L&I Effective date 08/14/2017 08/15/2017 Expiration date 08/15/2018 Insurance history Savings ............... Savings history Lawsuits against the bond or savings Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602032300&LIC=STEADCI984J7&SAW= 5/29/2018 STEADFAST CONSTRUCTION INC Cause no. 16-2-13930-2KNT • Complaint filed by VIEW AT THE LAKE LLC Complaint date 10/04/2016 Open Complaint against bond(s) or savings 9812818 Complaint amount $0.00 L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 993,689-00 Doing business as STEADFAST CONSTRUCTION INC Estimated workers reported Quarter 1 of Year 2018 "11 to 20 Workers" L&I account contact T3 / KENT ANDERSON (360)902-6963 - Email: ANDN235@Ini.wa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 05/03/2017 Inspection no. 317944371 Location 10811 S. E. 239 PI Kent, WA 98030 Inspection results date 12/10/2014 Inspection no. 317552578 Location 2111 SW 352nd ST. Federal Way, WA 98023 Inspection results date 07/13/2012 Inspection no. 315895425 Location 403 W. University Ellensburg, WA 98926 Violations Violations Violations Page 2 of 3 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602032300&LIC=STEADCI984J7&SAW= 5/29/2018