HomeMy WebLinkAboutPermit D18-0142 - ST THOMAS CATHOLIC CHURCH - REROOFST THOMAS CATHOLIC CHURCH 4415 S 140 ST BLDG 1 D18-0142 Parcel No: Address: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 1523049210 4415 S 140TH ST BLDG 1 DEVELOPMENT PERMIT Project Name: ST THOMAS CATHOLIC CHURCH Permit Number: Issue Date: Permit Expires On: D18-0142 6/20/2018 12/17/2018 Owner: Name: Address: COPR OF CATHOLIC ARCHDIOCES 710 9TH AVE , SEATTLE, WA, 98104 Contact Person: Name: OREN HADALLER Address: Contractor: Name: Address: License No: Lender: Name: Address: 19238 39TH AVE S , SEATAC, WA, 98188 Phone: (206) 372-3887 WASHINGTON BEST FINISHES LLC Phone: (206) 856-5286 3702 W VALLEY HWY N - SUITE 104 , AUBURN, WA, 98001 WASH IBF890NK Expiration Date: 8/12/2019 ST THOMAS CHURCH FUNDS 4415 S 185TH , TUKWILA, WA, 98168 DESCRIPTION OF WORK: REMOVE EXISTING ROOF MATERIAL; REPAIR ALL ROTTED WOOD; NEW OR HIGHER FACIA; ADD TAPERED FOAM INSULATION TO PROVIDE SLOPE FOR WATER RUNOFF; 1/2" DENSDECK FIRE BOARD/GYPSUM; 160 MIL BITUMEN TORCHDOWN ROOFING MATERIAL; ADD ALUMINUM ROOF COATING. SAME ROOFING MATERIALS & CONTRACTOR AS PERMITS D16-0018 AND D17-0062 Project Valuation: $51,250.00 Type of Fire Protection: Sprinklers: Fire Alarm: YES Type of Construction: Electrical Service Provided by: TUKWILA Fees Collected: $1,798.61 Occupancy per IBC: A-3 Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 Permit Center Authorized Signature: t Date: 100 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permmi and agree to the con itions attached to this permit. Signature: 44_ Print Name: 0 ?TR 6 Ci I /-eh" Date: 6`10 / O This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 5: TO SCHEDULE FIRE INSPECTIONS CALL 206-575-4407. 2: Application of roof coverings with the use of an open -flame device or use of a propane fueled asphalt kettle requires a separate permit from the Tukwila Fire Marshals Office located at 6300 Southcenter BI Suite 209 Tukwila, WA 98188. Telephone (206) 575-4407. There shall be not less than one multi-purpose portable fire extinguisher with a minimum 2-A20-B:C rating and a charged, minimum diameter 5/8 diameter water line(hose) on the roof being covered or repaired. (IFC 105.6.24, 3504.2.5, 3504.2.6) 1: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 3: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 4: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 6: ***BUILDING PERMIT CONDITIONS*** 7: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 8: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 9: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 10: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 11: Prior to final inspection for this building permit, a copy of the roof membrane manufacturer's warranty certificate shall be provided to the building inspector. 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0103 PRE-REROOF / \ CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov r \ Building Permit No. DI �1 Project No. Date Application Accepted: Date Application Expires: tit (b / (For office us • on CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION 1_t -H, / 5 So k r 1 B 4-k King Co Assessor's Tax No.: C he L Site Address:l/ y / S 5. /1 -ft' #4 TPA. )<t k'4 ' &I f S Suite Number: S ► % o w• a s �c..7 4- ca l' t Cit. u P. ell New Tenant: ❑ Yes 14..No Tenant Name: Floor: PROPERTY OWNER / Name: rt, 1^.N O`c' 4 - L 10 C -P5.0 p� S0q,--/H..e„ Address: /7 is 14.4 Jj v,� . �`S�t'ate: City: .¢4,11 / 55 1,l/,4 Zip: q ..e»f CONTACT PERSON — person receiving all project communication Name: d H..4, ti 444 J a 11..0 /- Address: 19 a.3 a3 yt�-v i j2 C City: S:j2 a —Fa c...._ State: w Zip: 91g� D Phone:0 6. 3 r7 2- 3 $8 7 Fax: — Email: 5vac)--„,C A a.�a i/41- S @ Pp »+Ca 5T, h..¢+ GENERAL CONTRACTOR INFORMATION II Company Name: "ISA S A t �/le�40 , . , 5- ! ' H 1 S h .0 4. Address:3ri c2 js/1r5-'V4 1/..1 N Sl., 1t 101—h City: H /1 , b N h State: w A Zip:q cDcot)I Phone�`: 6$ S6' s2 fs�o Fax: a 317" ifG a q Contr Reg No.: Exp Date: Tukwila Business License No.: W A514i 8 F $.16 N K H:\Applications\Forms-Applications On Line \2011 Applications\Fermit Application Revised - 8-9-11.docx Revised: August 2011 btu ARCHITECT OF RECORD Name: 5 4- tvi e 4s C' u t, / � -�it. ,..• )S Address: (4 S Sp / Fr S - Company Name: Architect Name: Address: City: State: Zip: Phone: Fax: Email - ENGINEER OF RECORD Name: 5 4- tvi e 4s C' u t, / � -�it. ,..• )S Address: (4 S Sp / Fr S - Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) 2 Name: 5 4- tvi e 4s C' u t, / � -�it. ,..• )S Address: (4 S Sp / Fr S - ZipgV , v City: .---j`u k , t ! a State:gust Page 1 of 4 / BUILDING PERMIT INFORMATION - 206-431-3670 Valuation of Project (contractor's bid price): $ `J i) Describe the scope of work (please provide R.A,D a l y- all r p i., '% o c ; 5 tl44to v.% 4d p ho v,`cl.a. Existing Building Valuation: $ 1 it D Ol (,SCO detailed information): R, y,, c LA A. At ,L 154 14 o p -j' yY, a-)91+ i dt 1 Now D ►- h ,9 ti -i2. s~ -Fac 1 a 1) a -I rQ S /p U J- c#9 J., tv 41,44? 1" 1.. !n tit O 7 P 1 y it P.R. 5 Da k -c 1 r.A I b ;-.1 tti tti► K -1 . f. m II( e'll d o w I'm 19c c .0 )h-ol .P 1" i I . / a cl I 1 , SA rvt..d- H e ect-: r9 N+ A.4.-12-4- i•a /5 e co het de 1.., Fs aI..d I'7-0®(2. es .. No If yes, a separate permit and plan submittal will be required. ))64%). el /94,11414'1/4; 9 yps14; J/,c w,, 4.5 p -I N+: i s -rt U l 6- oo l Will there be new rack storage? ❑ Y Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): 4 Gk -0 5 Floor area of principal dwelling: 15) D CO 41 Floor area of accessory dwelling: , ©DO *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. 47 '7 Number of Parking Stalls Provided: Standard: / D D Compact: Handicap: / Will there be a change in use? ❑ Yes FIRE PROTECTION/HAZARDOUS MATERIALS: 121- No If "yes", explain: R-aS:IA $C.�. INeg sit% 1-4-45 P`.''p1 Ram ❑ Sprinklers 0 ie Fire Alarm 0 None ®Other (specify) .r- t r e a 1 a..)-14'\ Will )- Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes gj No If "yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For or si a peptic system, provide 2 copies of a current septic design approved by King County Health Department. AM b IA i Id 1 kt y c 0 14 5 .Q k,42 h H: ApplicationsWorms-Applications On Line \2011 Applications'Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1't Floor 1_5;00o L IT y 0 'Y `� xI b N o co hi 14141.n.ii j Crt IA 1" cIN 2°d Floor 1 Yd Floor Floors thru Basement 5.e'0 ,1- ctP1 I'� ccesso true e* rY o5 . O , c.1a. Z ''7, 100 TJ Attached Garage q D I 1 'L l T Detached Garage Attached Carport \r Detached Carport "/ `/ Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): 4 Gk -0 5 Floor area of principal dwelling: 15) D CO 41 Floor area of accessory dwelling: , ©DO *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. 47 '7 Number of Parking Stalls Provided: Standard: / D D Compact: Handicap: / Will there be a change in use? ❑ Yes FIRE PROTECTION/HAZARDOUS MATERIALS: 121- No If "yes", explain: R-aS:IA $C.�. INeg sit% 1-4-45 P`.''p1 Ram ❑ Sprinklers 0 ie Fire Alarm 0 None ®Other (specify) .r- t r e a 1 a..)-14'\ Will )- Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes gj No If "yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For or si a peptic system, provide 2 copies of a current septic design approved by King County Health Department. AM b IA i Id 1 kt y c 0 14 5 .Q k,42 h H: ApplicationsWorms-Applications On Line \2011 Applications'Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 / 1 PUBLIC WORKS PERMIT INFORMATION — 206-433-0179 r 1 Scope ofWork(please provide detailed information): / I R00 F e��/ac p >n�ev."() 10w/.e>- ,f.etr,eI: cka�..c/) hNhS-4�7) f���ch..e�� s4o1"n9 eA)4cl wAllZ 1-v (s40.s e t�4ct+eI J4ro40) t TmrG e ow"t ►.vt`'Til 1--ap.r2H -pcel FO &N•. +a PpV(c)_I. S/o )7-12 t l �l J' Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila Xr... Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate 0 ...Valley View ❑...Sewer Availability Provided ❑ .. Highline ❑ .. Renton ❑ .. Renton ❑ .. Seattle Septic System: 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond 0 .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way 0 ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities 0 ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑ ...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line 11 17 0 .. Grease Interceptor 0 .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size .. 11WO # ❑ ...Water Only Meter Size WO # ❑ ...Deduct Water Meter Size ❑ ...Sewer Main Extension Public 0 Private 0 ❑ ...Water Main Extension Public 0 Private 0 11 FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) 0 ...Water ❑ ...Sewer 0 ...Sewage Treatment Monthly Service Billing to: Name: FY^, V, w N 0 h/{. 4 n ji Day Telephone:9-- 0 6 2Ji' - S Sd i Mailing Address: ti l'/ S S O 1 Lf 0 Gj fr./ 5 - City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O R OR AUT 1�i ZE AG Signature: `'1,", f Date: M a l 3)'2o 1g Print Name: h N I, 44 a g a` I 'e b Day Telephone: -2 c C 317 2-- 3 Cs -83 Mailing Address: i ”- 3 5r 3 9 4 f.& S. 5, a.Tac_ (A/ A 3 5/ .'-i,-- City - -City State Zip H:'ApplicationsTorms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 4 of 4 r Cash Register Receipt City of Tukwila eceipt Number R14423 DESCRIPTIONS ( ACCOUNT PermitTRAK QUANTITY PAID $1,798.61 D18-0142 Address: 4415 S 140TH ST BLDG 1 Apn: 1523049210 $1,798.61 Credit Card Fee $52.39 Credit Card Fee R000.369.908.00.00 0.00 $52.39 DEVELOPMENT $1,694.99 PERMIT FEE R000.322.100.00.00 0.00 $1,024.54 PLAN CHECK FEE R000.345.830.00.00 0.00 $665.95 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $51.23 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R14423 R000.322.900.04.00 0.00 $51.23 ., $1,798.61 Date Paid: Friday, May 04, 2018 Paid By: DREW MADALLER Pay Method: CREDIT CARD 004341 Printed: Friday, May 04, 2018 3:05 PM 1 of 1 'SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: o iL Typ of Inspection: ur/d N, E -z Adrd�ress: �` qi//5 u /4164 -Si; ate Called: Special Instructions: (/ (T *&u1020 prier/. Date Wanted: za---3 - 21 f Q� a.m. p.m. Re nester: C,Qen' I/a 1l e . i rP pproved per applicable codes. OMMENTS: or to approval. ZO -372.-3%1 q\'3Pr7kS\L -1P9c.91 Inspector: Date: REINSPECT! N FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 /)/8 ofi/z. Project: �-- �►,�,,r err {'k Cr/atXIG £ ,Type of Inspection: S ysi/LO/Alk 747%/4L_ Address: gills- 6 /�''�ir ,�io42i Date Called: Special Instructions: f1pp ti '�/� Date Wanted: LR '/ g F...111 r: Requester: Phone No: EiApproved per applicable codes. COMMENTS: Corrections required prior to approval. / f ' (rgaa1�.�j fM* Vii9pwe,Q) /� Sari J bJ( 1/0<5S yen( Zr Aid f/a� Inspector: te-Kooltr- Ons r -r Date. _ z„,, 2.0/5 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 -0 NZ Pro'ect: 4�4'� hs C- 31 Ty of Inspect' 'fie rbeC= i oin Ad LH/Sr ress:J 6= 11/0 '`'t Date Called: Special Instructions: BCG( It- Date Wanted: /" (Ci ___021 - 2L7� p.m. Requesternr Phone No: n( -37 z -3587 Approved per applicable codes. Corrections required prior to approval. COMMENTS: rrfT R t177o Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit --014-2- PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: 51. 774rni-s G -t ct- Type of Inspection: ri /�'�-- Address:Contact Suite #: 41ric 51 �0-� r S (. Person: �r2 �� Special Instructions: 7Z1 LAJafz►-c- STK21-ir67. Phone No.: — f /1.1k) p 6--(z w4 0 r- c g& 6arfrit---)3 & fmo Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: -icrii-f/fV F - AippiluvEt, Fire Alarm: Hood & Duct: - /AJ 7( etirw( /9. /for- fr\k•a /zs pt. --n .1 r- tZ ii- 7'd p c f-( bo h1 _._-10 d /AJ 6 /5 . /2E. -Q pit t p (Z 7Z1 LAJafz►-c- STK21-ir67. — f /1.1k) p 6--(z w4 0 r- c g& 6arfrit---)3 & fmo 6330 S. c. gtvt5, T'kw'1-4 42.0 ► 4 Needs Shift Inspection: Sprinklers: Hrs.: Fire Alarm: Hood & Duct: -..I Monitor: Pre -Fire: Permits: Occupancy Type: 4 f Inspector: f�-yyi 54--- Date: f j IZ.V _ $ Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 9 POLYFLEX° PRODUCT DESCRIPTION Polyflex membranes are premium, polyester reinforced Atactic Polypropylene (APP) modified bitumen roofing products specially designed for heat -welded applica- tions. Constructed with premium APP resins, and incorporating superior polyes- ter reinforcing, Polyflex provides an exceptionally durable roofing product which is easy to install and will provide long-term weathering performance. With a smooth surface and a polyolefin backing, Polyflex exceeds all minimum ASTM standards for tensile strength, puncture resistance and flexibility. Polyflex membranes can also be used as flashing membranes in all applicable specifications, in accordance with recommended installation practices. USES • Heat -welded base, interply or cap sheet • Applied directly over an acceptable substrate or as part of a multi -ply system • New roofing, re -roofing, re-cover and for flashing details FEATURES AND BENEFITS • Exceptional weathering characteristics • Puncture and tear resistant • Low -temp flexibility, exceptional tensile strength and elongation properties TECHNICAL DESCRIPTION TEST METHOD ASTM D5147 PROPERTY Peak Load @ 23+/-2°C (73.4+/-3.6°F), MD and XMD, min, kN/m (Ibf/in.) ASTM VALUE 8.8 (50) ASTM D5147 Elongation @ 23+/-2°C (73.4+/-3.6°F), MD and XMD, min (%) 23 ASTM D5147 Tear Strength @ 23+/-2°C (73.4+/-3.6F), min, N (lbf) 311 (70) ASTM 6222 Low Temperature Flexibility, max, °C (°F) 0 (32) REVIEWED FOR CODE COMPLIANCE APPROVED JUN 202018 City of Tukwila BUILDING DIVISION Copyright ©2014 by Polyglass U.S.A., Inc. and all rights are reserved Edition Date: 12/14 • Doc# Polyfee CITY OF TUKWILA i IAY 0 2018 PERMIT CENTER U%--Ot PRODUCT DATA Coverage (Approx) 100 sq ft Weight (Approx) 85 lbs Thickness (Nominal) 4.0 mm; 160 mils Roll Size 32'10" x 39 3/e" morn x lm) Rolls/Pallet 23 APPLICABLE STANDARDS • ASTM D6222, Type I • Miami Dade Code Compliance • Factory Mutual Approved • UL Classified for use in class A, B or C roofs, as listed in the latest UL "Roofing Materials and Systems Directory" • ICC ESR -2018 • TDI (illi) ezmin<> coo/d',l s <xi s Es PRODUCT WARRANTY Polyglass U.S.A., Inc. commercial roofing membranes can be backed with a manufacturer's warranty for up to 20 years when used as part of an approved, multi -ply roofing system. Please see your Polyglass U.S.A., Inc. Sales or Technical Representative for specifications and details. ROOFING AND WATERPROOFING SYSTEMS [POLYGLASS Q aMANI e OR OUP 1-800-222-9782 www.polyglass.com I' ' ' PR • DUCT /PP PR•D T POLYFLEX® APPLICATION INSTRUCTIONS Polyflex is intended to be used as a base, interply or cap sheet in new or re -roof applications. Polyflex may be applied directly to non-combustible substrates. Polyflex requires the installation of a compatible granulated cap sheet or approved roof coating to complete the roofing system. • Apply over clean, dry, dust and debris -free substrates. Prime concrete decks prior to application with PG 100 Asphalt Primer. • When re -roofing, remove all prior roofing materials down to a clean debris -free substrate and properly dose -off all abandoned roof penetrations. • Concrete or steel decks shall be designed with proper expansion devices. • Wood decks shall have all joints blocked and properly supported. • Ensure the fire rating of the assembly over any combustible substrate. • Ensure the installation of Polyflex does not prevent the ventilation of existing construction. • Do not apply over shingles or any granulated surface. • While installing Polyflex: 1. Start at the low point of the roof. 2. Unroll the material and allow to relax. 3. Install with traditional torch roofing techniques ensuring proper heating of the roofing material as not to expose the reinforcement. 4. Do not heat the substrate. 5. Position successive rolls providing a minimum 6" end lap and 3" side lap. Asphalt bleed out shall be 1 /4" to 3/8" on all seams. 6. It is suggested but not mandatory that laps shall be rolled with a 6" -wide roller immediately after heat welding. • Details and flashing may be installed using Polyflex with torch applied techniques. Do not use cold adhesives or hot asphalt. Check project details for proper installation requirements. POLYGLASS U.S.A., INC. MANUFACTURING FACILITIES • Fernley, NV • Hazleton, PA • Winter Haven, FL CORPORATE HEADQUARTERS Polyglass U.S.A., Inc. 1 1 1 1 West Newport Center Drive Deerfield Beach, FL 33442 www.polyglass.com General Line: (888) 410-1375 (954) 233-1330 Customer Service: (800) 222-9782 Technical Service: (866) 802-8017 Questions? technical@polyglass.com Product Disclaimer: Unless otherwise incorporated into or dart of a supplemental manufacturer's warranty, Polyglass warrants its product(s) against manufacturing defects in its product that directly results in leakage for a perioc of 5 years. Refer to material safety data sheet (MSDS) for specific data and handling of our products. All data furnished refers to standard production and is given in good faith within the applicable manufacturing and testing tolerances. Polyglass U.S.A., Inc., reserves the right to improve and change its products at any time with- out prior notice. Polyglass U.S.A., Inc. cannot be held responsible for the use of its products under conditions beyond its own control. For most current product data and warranty information, visit www.polyglass.com Copyright ©2014 by Polyglass U.S.A., Inc. and all rights are reserved Edition Dote: 12/14 • Doc# Polyllex ING AND WATERPROOFING SYSTEMS MAPF/ GROUP 1-800-222-9782 www.polyglass.com TECHNICAL PRODUCT DATA SHEET TECHNICAL DETAILS WEIGHT/ROLL 75 lbs. 34.2 kg WIDTH 393/8" 1m THICKNESS 50 mils nominal ROLLS/PALLET 20 from OR/CA/OK WEIGHT/SQUARE 25 lbs. 11.3 kg LENGTH 99' 30.2 m COVERAGE 3 square TOTAL AREA PER ROLL 325.1 sq. ft. 30.2 m2 LAY LINES 2", 4", 121/2", 183/4" 51 mm, 102 mm, 318 mm, 476 mm TEST COMPLIANCE ASTM D4601 Type II 0 LISTED ASTM E108 Class A Fire Rating W c fD US Intertek APPROVED FEATURES & BENEFITS • Made with oxidized asphalt • Base sheet for use in conventional multi -ply BUR roof systems COMPATIBLE ADHESIVES MCOFfD ASPHALT GOLD AMINES HOT ASPHALT BASE LOW SLOPE — COMMERCIAL — CONVENTIONAL MEMBRANES — SKU: 515 VOL FIBERGLASS REINFORCED BASE SHEET PRODUCT USE 515 Panel" Base is suitable for use as a base sheet for hot asphalt, cold process or torch -applied application. This quality base sheet may be used over various combustible and non-combustible decks as the initial ply for specified roof systems. It is approved for use on all fire -rated built-up roofing. Please consult Malarkey Technical Services for approval of roof systems. COMPOSITION & MATERIALS f 515 Pano"' Base is manufactured on a fiberglass mat, impregnated and coated on both sides with oxidized bitumen (asphalt), and surfaced with a mineral release material. APPLICATION/INSTALLATION [515 Pano'" Base shall be applied as specified. See Malarkey Specification Manual for specific installation instructions. 515 Pano`" Base may be applied in cold weather, but follow cold weather application instructions and general requirements. Contact Malarkey's Technical Services Department for details. STORAGE & HANDLING 5f--1-E-10anoT" Base requires dry storage and protection from the weather. Roof decks should be sound, dry, I smooth, meet necessary local requirements, and provide positive drainage. Do not apply wet membrane sheets. WARRANTY [Malarkey Roofing Products® offers various warranties to meet specific requirements. The warranty package for 515 Pano"' Base includes 5, 10, 15, and 20 -year limited and unlimited coverage. Contact your roofer, local distribution center or Malarkey for full details. See below for TECHNICAL ASSISTANCE contact information. 515 Pano"' Base and other Malarkey products are available throughout North America and Pacific Rim countries. Visit WWW.MALARKEYROOFING.COM for additional product information and availability. REVIEWED FO CODE COMPLIANCE APPROVED JUN 2 0 2018 City of Tukwila BUILDING DIVISION Effective 11/15 Supersedes all previously published data Check for most current version on our website. WWW.MALARKEYROOFING.COM Malarkey Roofing Products® (Malarkey) inventory SKU number for this product: 515 Panel" Base SIB 01''L TECHNICAL ASSISTANCE: Malarkey has technical services assistance available. Contact Malarkey for details: Call weekdays 7:00 am to 5:00 pm PST, at 800.545.1191 or 503.283.1191. technicafinquiries@malarkeyroofing.com RECEIVED CITY OF TUKWILA NAY 042018 PERMIT CENTER CORPORATE OFFICE: 3131 N. Columbia Blvd. Telephone: 503.283.1191 Portland, OR 97217-7472 or 800.545.1191 P.O. Box 17217 Fax: 503.289.7644 Portland, OR 97217-0217 LOW SLOPE — COMMERCIAL — CONVENTIONAL MEMBRANES — PANO'" BASE — SKU: 515 Page of 2 TECHNICAL PRODUCT DATA SHEET FIBERGLASS REINFORCED BASE SHEET PHYSICAL PROPERTIES Break Strength, 73.4°F (23°C) as manufactured, MD, min, Ibf/in (kN/m) Break Strength, 73.4°F (23°C) as manufactured, CD, min, Ibf/in (kN/m) Pliability at 73.4°F (23°C) Net dry mass—coated sheet minimum g Ib/100 ft2 (g/m2) Mass of desaturated glass mat, min, Ib/100 ft2 (g/m2) Asphalt, min, Ib/100 ft2 (g/m2) Moisture, % at manufacture Thickness (granulated surface), mils (mm) PAN€ BASE LOW SLOPE — COMMERCIAL — CONVENTIONAL MEMBRANES — SKU: 515 ASTM TEST ASTM D4601, TYPE II PANO' BASE METHOD STANDARD SPECIFICATIONS TYPICAL RESULTS D146 44 (7.7) D146 44 (7.7) D228 9/10 pass 15.5 (756) 1.7 7.0 (342) 1 D228 D228 D228 D228 D5147 N/A 70 (12.2) 50 (8.75) 10/10 Pass 23.1 (1127) 1.8 8.2 (400) <1.0 50 (1.3) 515 Pano- Base is a fiberglass base sheet that meets the requirements of ASTM D4601, Type II and when used in approved systems, is Class A fire rated with Underwriters Laboratories and lntertek Testing Services. It can also be used as a component in FM systems. Contact Malarkey's Technical Services Department for details. Effective 11/15 Supersedes all previously published data Check for most current version on our website. WWW.MALARKEYROOFING.COM TECHNICAL ASSISTANCE: Malarkey has technical services assistance available. Contact Malarkey for details: Call weekdays 7:00 am to 5:00 pm PST, at 800.545.1191 or 503.283.1191. technicalinquiries@malarkeyroofing.com CORPORATE OFFICE: 3131 N. Columbia Blvd. Telephone: 503.283.1191 Portland, OR 97217-7472 or 800.545.1191 P.O. Box 17217 Fax: 503.289.7644 Portland, OR 97217-0217 LOW SLOPE — COMMERCIAL — CONVENTIONAL MEMBRANES — PANO"" BASE — SKU: 515 Page 2of2 MANUFACTURER Georgia-Pacific Corporation 55 Park Place, 19th Floor Atlanta, GA 30303 Technical (800) 225-6119 (8-6 ET) DESCRIPTION DensDeck Prime" Roof Guard is an excep- tional fire barrier, thermal barrier and recovery board used in various commercial roofing systems. The product features a pre -primed surface to make the bond even stronger. The patented DensDeck design employs glass mat facings front and back that are embedded into a water resistant and moisture -resistant treated core, providing excellent fire resistance, moisture resistance and wind uplift properties. The unique construction of DensDeck Prime provides superior flute spanning and will help stiffen and stabilize the roof deck. Additionally, DensDeck Prime has been shown to withstand delamination, deterioration, warping and job -site damage more effectively than roofing membrane substrates such as paper -faced gypsum board, fiberboard and perlite insulation. DensDeck Prime resists the growth of mold and mildew per ASTM D 3273. Roof system manufacturers and designers have found DensDeck Prime Root Guard to be compatible with many types of roofing systems, including: modified asphalt, single -ply, metal systems, recover board, as well as an overlayment for polyisocyanurate and polystyrene insulation. DensDeck Prime can also be used as a form board for poured gypsum concrete deck in roof applications as well as a substrate for spray foam roofing systems. 'h" and %" DensDeck Prime may also be used in vertical applications as a backer board or liner for the roof side of parapet walls. DensDeck Prime allows the bonding of cold mastic modified bitumen and torching directly to the surface. Consult with the system manufacturer for recommendations on thls application. System manufacturers and designers have found DensDeck Prime to be compatible with bonding adhesives for fully -adhered single - ply membrane applications and has been shown to extend the adhesive usage. DensDeck Prime's exceptional moisture resistance make it the preferred substrate for vapor retarders. SUBMITTAL APPROVALS: (Stamps or Signatures) ❑ 1/4'-6.4mm 0 '-12.7mm ❑ 5/8"-16mm DENSDECK Roof Guard PRIME An excellent fire barrier, DensDeck Prime features a noncombustible core and inorganic surface that offers greater fire protection than other conventional commercial roofing products when applied over combustible roof decks and steel decks. DensDeck Prime is FM tested and approved as the only 1/2" gypsum product to meet the calorimeter requirements for conven- tionally insulated decks. Tested in accordance with ASTM E 84, its surface burning character- istics are Flame Spread -0 and Smoke Developed -0.5%" DensDeck Prime can replace any generic Type X gypsum board in any roof assembly in the UL Fire Resistance Directory under the prefix "P' LIMITATIONS DensDeck Prime is designed to act with a properly designed roof system. The actual use of DensDeck Prime Roof Guard as a roofing component is the responsibility of the roofing system's designing authority. Georgia-Pacific does not offer roofing system design services. Conditions beyond the control of Georgia-Pacific such as weather conditions, dew, application temperatures and techniques may cause adverse effects with adhered roofing systems. Always consult roofing manufacturers for their specific instructions on applying their products to DensDeck Prime roof board. Panels must be kept dry before, during and after installation. Apply only as much DensDeck Prime as can be covered by a roof membrane system in the same day. Accumulation of water due to leaks or conden- sation in or on DensDeck Prime Roof Guard must be avoided during construction and after construction. Avoid over -use of non -vented direct -fired heaters during winter months. Avoid application of DensDeck Prime during rains, heavy fogs and other conditions that may deposit moisture on the surface. The need for a separator sheet between the DensDeck Prime Roof Guard and the roofing membrane shall be determined by the roof membrane manufacturer or roofing systems designer. When applying solvent -based adhesives or primers, allow sufficient time for the solvent to flash off to avoid damage to roofing components. Maximum flute span is 25/2" for 'A" DensDeck Prime; 5" for Y" DensDeck Prime; and 8" for 5N' DensDeck Prime Fireguard' Type X. Consult membrane manufacturer for specific system installation instructions. )TM TECHNICAL DATA Flame spread 0, smoke developed 0, when tested in accordance with ASTM E 84 or CAN/ULC-S102. Noncombustible when tested in accordance with ASTM E 136. DensDeck Prime Fireguard: UL Classified when tested in accordance with ASTM E 119. 1/4" DensDeck Prime has been tested in GP sponsored tests with Factory Mutual for 60 psf and 90 psf wind uplift for BUR, EPDM, thermoplastics and modified bitumen roof systems. Higher wind uplift ratings have been achieved by numerous membrane manufacturers using DensDeck Prime in their FMRC-approved construction designs. INSTALLATION 1. DensDeck Prime should be used with fasteners specified in accordance with FM requirements and roof membrane manufacturer's written recommendations. 2. For wind uplift/FMRC compliance where DensDeck Prime is mechanically attached to metal decks, DensDeck Prime shall be installed to the specifics of the FMRC design assembly. 3. For installations involving BUR, EPDM, thermoplastics and modified bitumen roof systems, call the GP Technical Hotline at 1-800-225-6119 for fastener patterns of GP's FMRC uplift assemblies. 4. In accordance with approved shop drawings, FM -approved fasteners shall be installed with plates through the DensDeck Prime, flush with the surface. 5. Where DensDeck Prime is installed over combustible wood decks or insulation, all joints should be staggered. The optional separator sheet should be installed prior to DensDeck Prime installation. 6. Edge joints should be located on, and parallel to, deck ribs. End joints of adjacent lengths of DensDeck Prime should be staggered. 7. For FM Class 1-60, fastener density typically is increased by 50% at the roof corners, in conjunction with FM -approved covering. 8. For FM Class 1-90, fastener density typically is increased by 50% at the roof corners and roof perimeter, in conjunction with FM -approved covering. ISO 9000 ID No.: S723 -PRD -074 G•P Gypsum a Georgia-Pacific company 9. Adhered Systems: Insta-Foam Products, Incas Insta-Stik Adhesive used with 3/4" DensDeck Prime" achieved la FMRC Class 1-180 according to test report 1Y7A5.AM in selected Class 1 insulated steel and concrete deck roof construction. Contact Insta-Foam Products, Inc. for details at 1 -800 -800 -FOAM. PRODUCT DATA Thickness: 3/4" (6.4mm), 'h" (12.7mm); 5.5" (15.9mm) Fireguard' Type X Widths: 4' (1220mm) standard, '%" (3mm) tolerance Lengths: 8' (2440mm) standard, tolerance' /4" (6.4mm); Optional: 4' (1220mm) available 10. DensDeck Prime shall be installed with Edges: Square ends and edges butted tightly. 11. DensDeck Prime is manufactured to conform to ASTM C 1177. Spanning: '/4" DensDeck Prime spans flute widths up to 25%"; 1/2° DensDeck Prime spans flute widths up to 5"; 5/8" DensDeck Prime spans flutes up to 8" wide PHYSICAL PROPERTIES PROPERTIES 1/4" DENSDECK PRIME" 1/2" DENSDECK PRIME" %" DENSDECK PRIME'" FIREGUARD* Thickness, nominal Inches 5'i6" W 5,8" Width, standard 4' 4' 4' Length, standard 8' * 1/4" 8' t'W 8' t'A" Weight, IbsJM sq. ft., nominal 1100 1950 2500 Surfacing Glass mat/primed Glass mat/primed Glass mat/primed Flexural Strength, Parallel, lbs. min.' 40 803 100' Flexural Strength, Perpendicular, lbs. mkt.' 50 100' 140' Flute Spanability' 25/e" 5" 8" Permeance Perms' 50 35 32 R Value' .28 .56 .67 Coefficient of Thermal Expansion, Incheslinch/°F 8.5 x 104 8.5 x 104 &5 x 104 Linear Variation with Change in Moisture infin/%RH 6.25 x 10' 6.25 x 104 6.25 x 104 Absorption, 0/ max' 10.0 10.0 10.0 Compression, psi 500 500 500 Surface Water Absorption, grams' 2.5 2.5 2.5 Flame Spread Smoke Developed (ASTM E 84) 0 0 0 Are Classification UL Class A, ULC S-102 UL 1256, ULC S-126 FMRC Class 1 UL 1266, ULC S-126 UL Class A, ULC 102 FMRC Class 1 LL Classified "P" assemblies ULC S-101 FM Uplift Approvals 60 and 90 psf uplift FMRC 1-60, 1-90 FMRC 1-60, 1-90 'Tested in accordance with ASTM E 661 (400 Ib. conc. load), 'Tested in accordance with ASTM C 473. 'Tested in accordance with ASTM C 355 (dry cup method). 'ASTM C 1177 minimums. 'Tested In accordance with ASTM C 518 (heat flow meter). Technical information U.S.A. and Canada: 1-800-225-6119 Mon. -Fri., 8 a.m.-6 p.m. Sales Information and Order Placement U.S.A. Midwest: 1-800-876-4746 South: 1-800-327-2344 Northeast: 1-800-947-4497 West: 1-800-824-7503 CANADA Canada Toll Free: Quebec Toll Free: Canada Toll Free Fax: Or visit our Web site at www.gpgypsum.com 1-800-387-6823 1-800-361-0486 1-800-387-8975 Firestone BUILDING PRODUCTS ISO 9000 ID No.: S723 -PRD -074 e Geoigla-P«cific company H -SHIELD Flat Pol yi!ocyanurate Insu,ation H -Shield PRODUCT DESCRIPTION H -Shield is a rigid roof insulation panel composed of a closed cell polyisocyanurate foam core manufactured on-line to fiber reinforced facers on each side (GRF). FEATURES AND BENEFITS Manufactured with NexGen Chemistry:: Contains no CFCs, HCFCs, is Zero ODP, EPA Compliant, and has virtually no GWP Approved for direct application to steel decks Approved under all major roof covering systems — BUR, Modified and Single -Pty PANEL CHARACTERISTICS Available in two grades of compressive strengths per ASTM C1289 Type II, Class 1 Grade 2 (20 psi) or Grade 3 (25 psi) Available in 4'x4' (1220mm x 1220mm) and 4`x8' (1220mm x 2440mm) panels in thicknesses of 1" (25mm) to 4.5" (114mm) ROOFING APPLICATIONS • Constructions requiring FM Class 1 and UL Class A ratings • Single -Ply Roof Systems (Ballasted, Mechanically Attached, Fully Adhered) • Standing Seam Metal Roof Systems • Modified Bitumen Systems Built -Up Roofing: Asphalt and Coal Tar H -SHIELD THERMAL VALUES THICKNESS LTTR FLUTE (INCHES) (MM) R VALUE* SPANABILITY 1.00 25 1.50 38 1.80 46 2.00 51 2.50 64 2.60 66 3.00 76 3.50 89 3.80 97 4.00 102 4.30 109 4.50 114 5.7 8.6 10.3 11.4 14.4 15.0 17.4 20.5 22.3 23.6 25.5 26.8 2 5/8" 4 3/8" 4 3/8" 4 3/8" 4 3/8" 4 3/8" 4 3/8" 4 3/8" 4 3/8" 4 3/8" 4 3/8" 4 3/8" *Long Term Thermal Resistance Values are based on ASTM C 1289. ISG 11—' h .* J ''r ( /G. s s Codes and Compliances • ASTM C 1289 Type II, Class 1 Grade 2 (20 psi) or Grade 3 (25 psi) • International Building Code (IBC) Chapter 26 • State of Florida Product Approval Number FL 5968 • Miami Dade County Product Control Approved Underwriters Laboratories Inc Classifications • UL 1256 • Insulated Metal Deck Construction Assemblies — No. 120, 123, 292 • UL 790 - UL 263 Hourly Rated P Series Roof Assemblies UL Classified for use in Canada • Refer to UL Directory of Products Certified for Canada for more details • CCMC 13460-L • UL Certified for Canada, CAN/ULC-5126, CAN/ULC-S101, CAN/ULC- S107 • CAN/ULC-S704 Type 2, Class 3 (20 psi) or Type 3, Class 3 (25 psi) Factory Mutual Approvals • FM 4450, FM 4470 • Approved for Class 1 insulated steel deck constructions for 1-60 to 1-270. Refer to FM Approval's RoofNav for details on specific systems LEED Potential Credits for Polyiso Use Energy and Atmosphere • Optimize Energy Performance Materials & Resources • Building Life -Cycle Impact Reduction • Environmental Product Declarations • Materials Reuse • Recycled Content • Construction and Demolition Waste Management WWW .. H U N T E R P A N E L S .COM 8 8 8. 7 4 6. 1 1 1 4 HUNTER PANELS ENERGY SMART P O LY I S O TYPICAL PHYSICAL PROPERTY DATA CHART PER ASTM C 1289 — POLYISO FOAM CORE ONLY PROPERTY TEST METHOD Compressive Strength ASTM D 1621 VALUE 20 psi* (138kPa, Grade 2) Dimensional Stability ASTM D 2126 2% linear change (7 days) Moisture Vapor Transmission Water Absorption ASTM E 96 ASTM C 209 < 1 perm (57.5ng/(Pa • s • m2)) < 1% volume Flame Spread** ASTM E 84 < 75 Smoke Developed** ASTM E 84 < 450 Service Temperature -100° to 250° F (-73°C to 122°C) *Also available in 25 psi, Grade 3 **Meets the requirements of the IBC code. For specific Flame Spread or Smoke Developed Ratings - please contact the Hunter Panels Technical Department. Single -Ply Systems Ballasted Single -Ply Systems Each H -Shield panel is loosely laid on the roof deck. Butt edges and stagger joints of adjacent panels. Install the roof covering according to the manufacturer's specifications. WARNINGS AND LIMITATIONS Insulation must be protected from open flame and kept dry at all times. Install only as much insulation as can be covered the same day by completed roof covering material. Hunter Panels will not be responsible for specific building and roof design by others, for deficiencies in construction or workmanship, for dangerous conditions on the job site or for improper storage and handling. Technical specifications shown in this literature are intended to be used as general guidelines only and are subject to change without notice. For more information refer to the Storage and Handling Technical Bulletin at www.hpanels.com, or refer to PIMA Technical Bulletin No. 109: Storage & Handling Recommendations for Polyiso Roof Insulation at www.polyiso.org. INSTALLATION Mechanically Attached Single -Ply Systems Each H -Shield panel must be secured to the roof deck. Butt edges and stagger joints of adjacent panels. Install the roof covering according to the manufacturer's specifications. Fully Adhered Single -Ply Each H -Shield panel must be secured to the roof deck. Maximum 4'x4'(1220mm x 1220mm) panels of H -Shield may be adhered to a prepared concrete deck or subsequent layers of insulation with a full mopping of hot steep asphalt, insulation adhesive or cold applied mastic. Butt edges and stagger joints of adjacent panels. Install the roof covering according to the manufacturer's specifications. Built Up, Coal Tar And Modified Bitumen Systems (APP, SBS) Each H -Shield panel must be secured to the roof deck. Maximum 4'x4' (1220mm x 1220mm) panels of H -Shield may be adhered to a prepared concrete deck or subsequent layers of insulation with a full mopping of hot steep asphalt, insulation adhesive or cold applied mastic. Butt edges and stagger joints of adjacent panels. Install the roof covering according to the manufacturer's specifications. R-30.0, two layers of 2.6" H -Shield with Single -Ply membrane To achieve optimal thermal performance, Hunter Panels recommends installation of a multi -layered system with staggered joints. HUN+ E R Energy Smart Polyiso HUNTERPANELS.COM 15 FRANKLIN STREET, PORTLAND, ME 04101 • 888.746.1114 • FAX: 877.775.1769 PIMAQualityMark" The Certified LTTR-value k•PIMA POLYISOCYANURATE INSULATION MANUFACTURERS ASSOCIATION NEW YORI( • ILLINOIS • FLORIDA • TEXAS • UTAH • PENNSYLVANIA • WASHINGTON 1116 POLYGLASS Owners Name: Saint Thomas Church 12 Year (10 Year Non -Coated)* LIMITED ROOFING MATERIAL WARRANTY ('Warranyisself-executed Winter) Owner's Complete Address: 4415 S 140th St, Tukwila, WA 98168 Building Name: Saint Thomas Church Roof Building Complete Address: 4415 S 140th StLTrtkwile, WA 98168 Roofing Contractor Name: Washington Best Finishes, LLC Roofing Contractor Complete Address: 3702 West Valley Hwy. N. Suite 104 Auburn, WA 98001 Roofing Contractor Phone: 208 856 5286 Polyglass Registered Contractor # (as applicable): Polygtass Product(s) Used: Polyglass Polyflex App 4-0 Smooth Other Roofing Products Used: Project Size: Squw. Fest Completion Date: TERMS AND CONDITIONS: Definitions:-Polyglass” shall mean Polyglassa U.S.A, Ina 1111 W. Newport Canter dive; Deerfield Beach, FL 33442. 'Owner' shall mean the original patty titled above as Owner's Name whose building the Polyglots roof membrane product Is installed. Polygtass warrants; the Polyglass product to be free from manufacturing detests which effects the ability of the membrane to perform in a watertight manner (herein considered defective) for the period of Twelve (12) years from the date of original installation of the roofing membrane for all Mineral Surfaced, Polyreffece, and Fibered Aluminum and Aa 4lc coated membranes. FiReen (15) years for Emu(sion/Fbered Aluminum or £mltaIoniAaylie coated. Smooth surfaced membranes with or without Non•Frbered Aluminum coating will be limited to Ten (10) years. This warranty s for the sole benefit of Owner described above ("Owner'} and is not transferrable or assignable. Warranty must be completed in its entirety and registered wsT Polyglots to become in effect othervlse the Polyglass membrane shall have warranty protection as provided by its Product Liability Coverage on packaging. A legible copy of this Warranty and proof of purchase must be registered with Polyglaas USA, Inc. Atm: Warranty Department 1111 W. Newport Center Drive; Deerfield Beach, FL 33422 wtttin 90 days of the original date of purchase. Should Polyglot membrane be deemed defective by Polyglass, as described above,. Polyglass shall exercise the option to repair or replace such defective materials, excluding any associated tabor to perform these tasks. Potygtass' maximum lathy, under any circumstances, shag not exceed the cost of the defective membrane at time of Balm; excluding afi installation related labor costs; costs of flashing, metal work, or other materials not supplied or furnished by Polygram. This sum shall be pro -rated at year Two (2) of its term, reduced by 1112; (1/15) for 15 Year (1/10) for 10 year, remaining in the warranty period and further reduced by any cost previously incurred by Polygram for the repair or replacement of any Paiygless materials under this warranty. My such repot or replacement to remedy leakage shall be owlets SOLE AND EXCLUSIVE REMEDY against Polyglots. M terns and cond5ons under this warranty will be governed under Florida Law. Polyglass shall have no obligation basad upon the following exclusions under this warranty: 1) Damage by natural disasters, inckiding but not tinted to Lightning. Hall, strong winds exceeding 9 on the aeaufort Scale, Floods, Hurricanes, Tornadoes, wind launched debris, Earthquakes or similar acts of god or natural causes; 2) Damage by willful or negligent acts, Fire, Vandalism, mother Moues; 3) Damage by use of materials not furnished by Polygram; 4) Owner or lessee fads to comply with Polyglots Roof Mentenance Warranty Guidelines. Polyglass Roof Makdenance Warranty Guidelines is available at: wwwkAdvolasa.us 5) Damage by structural fanure. including, without latdtation, settling or shifting of the building, Of movement, crating, or deflection of the roof deck. roof substrate, roof insulation, bulking design or construction, inadequate attic ventilation; 4) Damage by any chemical condition not disclosed to Polygram, or traffic or storage of mandate or infilration of condensation or moisture In, through or around the walls, toping, building structure of the underlying or surrounding areas: 5) Afteratons or repairs made on or through the roof or objects (inducing, without limitation, machines, structures, fixtures, or utilities) are placed on the roof without prior written authorization of Polyglass; 8) Metal work or other materials not furnished by Polyglots and used M the rooting system resuking in Maks; 7) Poor workmanship in the original application of materials as determined in Polygiass' sole judgment; 8) Failure to utilize Polyglass' latest instructions end recommendations as to installation procedures; 9) Damage resulting from lade of positive, proper or adequate drainage: 10) Loss in part or M whole of granule or other surfacing; 11) Damage or injury arising in any way from an actual or alleged &chergs or release of any pollutant or waste, environmental or airborne contaminates; - 12) Damage or injury arising In any way from teatingraampling of the membrane, design and consulting errors or omissions. 13) Failure to register this warranty within DO days of purchase to Polygtass. 14) Protective coating or other surfacing material not covered by these warranty coverages. Coverage is limited to membrane compound and mat reinforcement. In addition to kerns 1-16 above, owner agroea by registration of this warranty that Poygtass shall have no responsibility whatsoever ler bo0y injuy to any person or damage to the structure or its contents throaty or inthrecty arising out of any defects in is roof membrane or arty other consequential or incidental damages or attorneys fees. Polygram' sof* rsponsiblkty is the repair or replacement of defective membrane that is directly related to leakage. This warranty does not hndude the cost of removal of existing materials, or the cost of labor to repair or replace the defective membrane and/or overburden installed to the Polyglots membrane. Conditions related to items 1-15 above, with the exception on items 8,12 & 18 shalt result in Immediate termination of this warranty in its entirety without further notification from Polygtass. Claim Procedure: Polyglots shell have no obligation under this warranty unless Owner shall have promptly notified Pofyglass M writing *brig with attached Proof of Purchase to Polyglass by registered or certified mel. Direct all claims to Polyglass, U.S.A, Inc. 1111 W. Newport Center Drive, Deerfield Beach, Florida 33442, ATTN; Warranty Department Any claim shwa provide a copy of warranty and detailed Information of the leakage and aneged refect. Polygram must receive such notice within ten (to) days after discovery of the clamed defeat failure to notify will result in voiding of this warranty. Polyglass mimosa the right to request retained samples from the roof to be provided at Owner's expense and submitted to Polyglass for analysts In lieu of any site review or 111-servk. materials. Owner shag provide Polygtass, and its agents and employees, free, safe and reasonable access to en roof dumng regular business nous during the tern of the warranty. Owner shell be responsible for all costs related to safe and reasonable access to investigate Maim. Failure to comply well result in voiding of this warranty. Polyglass' good -faith determination of the source of leakage, damage, or alleged defect to the roof shell be exclusive and banding to owner. Painless' forlorn at any time to enforce any of the terms and conditions of this warranty stall not be construed es a waiver of such provisions. Polyglass reserves the nght to discontinue or modify any of its products and shall not be liable to Owner as a result of any such discontinuance or modification. This constitutes your entire express warranty for the produce or system of products purchased. To the extent permitted by law, all other warranties, whether express or implied, including, but not limited to the implied warranties of MERCHANTABILITY and FITNESS FOR A PARTICULAR PURPOSE are EXCLUDED. ANY IMPLIED WARRANTIES ARISING BY OPERATION OF LAW ARE LIMITED 114 DURATION TO THE TERM OF THIS WARRANTY. POLYGLASS WILL NOT PAY OR 88 LIABLE UNDER ANY CIRCUMSTANCES FOR INCIDENTAL. CONSEQUENTIAL, SPECIAL OR EXEMPLARY DAMAGES. OR FOR LAST PROFITS OR BUSINESS INTERRUPTION LOSS. YET, SOME STATES 00 NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, OR THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. No implied warranty can be modified by any course of dealing, course of perfomance or usage of trade. This warranty gives you specific legal rights and you may also have other rights which vary from Web stab. NO REPRESENTATION, PROMISE. AFFIRMATION OR STATEMENT BY ANY EMPLOYEE OR AGENT OF POLYGLASS WILL BE ENFORCEABLE AGAINST POLYGLASS UNLESS IT IS SPECIFICALLY INCLUDED IN THIS WARRANTY. POLYGLASS' AGENTS HAVE NO AUTHORITY TO ONE WARRANTIES BEYOND THOSE PROVIDED IN THS WARRANTYALL RIGHTS AND DUTIES ARISING UNDER THIS WARRANTY SHALL BE GOVERNED BY FLORIDA LAW. Warranty presented and desernonsd as incarnates or inaccurate shag be considered null and void. By Including the signature below, I confirm that I have ad and *knowledge the above Terms and Conditions of this warranty. Ot res $ (Mature ate Due to document atm print and submit on INN, Ar x711• Iliad paper or n 1 papas 012014Urt?w15SE a. To Who Concern: WASHINGTON B8TFINISHESy LLC 3702 West Valley Hwy. H. Suite *104 Auburn, WA 98001 Tel 206 856 5286 fax 253 737 4629 From: Israel Alvarez Project: Saint Thomas Church Location: 4415 S 140th St, Tukwila, WA 98168 Warranty of Workmanship Washington Best Finishes, LLC, confirmed the warranty of workmanship for a period of five years for the roof Installation in the project of: Saint Thomas Church located at 4415 S 140th St, Tukwila, WA 98168. This warranty started on July 25, 2016. %sra0 Pte" Israel Alvarez President Washington Best Finishes, LLC 3702 West Valley Hwy. N. Suite #104 Auburn, WA 98002 c , Fk. 7 d vt (4, gt. )),4 kit 1.1 74.) A Co le c-71 e -P -4- 11 4.7 i / 44" tifect• *7p/7 t, 1-4 /-4 v LA_ 5Iik1y A C )-V -Z 2 k+ w -2 (7 2 o 5--- - - — REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 O2018 City of Tukwila BUILDING DIVISION et- R_- R Li I i441ttt-Li" 5 11 ',di CORRECTION LTR# RECEIVED CITY OF TUKW1LA JUN (17 2018 PERMIT CENTER L1,0 Lk, fr• ‘1,‘ IA 9 1't 6 11^4- o /1 14- 45 it A , .0 ,‹ 1-T ti c404, R 2-6.53 ; Ree.s A 14-• ill 2- v „ �, Zoi5-- d 1-4-? NC'd t 1 l h _4 vl C ‘ ca 1-4 l< G c tt / REVIEW"v.D FOR CODE COMPLIANCE- APPROVED JUN 20 2018 City of Tukwila - BUILDING DIVISION All products will be purchased from Allied Building Products, Kent 253 872-4400. Joe Bischoff will be happy to work with all of us to identify their products that meet the overall objectives for the multiply layers that are to be added on top of the roof deck. They are very pleased to be working with Israel on this project OK let's see if I got this right. Layers from the top down are: 1. Tri -Built Fibered Aluminum exterior Coating meets ASTM D-2824, Type III 2. PolyGlass - Polyflex or Tri -Built APP smooth by PolyGlass, polyester reinforced APP modified bitumen roofing product. 160 mil thick. Torch down. ASTM D 6222 Type I 3. Panobase 515 by Markey Roofing Products, 50 mil thick base sheet for torch down asphalt roofs, ASTM D 4601 Type II. Qualifies as a vapor barrier. (nailed down) 4. / inch thick DensDeck roofing board, a gypsum board. This board is fire rating. http://www.buildgp.com/roofboard densdeck 5. 2 inch thick H -Shield Insulation board (4 ft. x 8 ft. R-11.4 Polyisocyanurate Rigid). ASTM C 1289 Type II Class 1, grade 2 or 3. This is a closed cell foam panel. - 5'J & 4 o w i 1 h A 6. Over the existing bare plywood roof deck. 4-0 rko pi-ovr w,„ REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 0 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA i -SAY 0 k 2018 PERMIT CENTER MW2- U31N20 11W�13d Map dataF P '8 go tote ft 0 0 (13 w 0 O_ G) 0 0 co m N 5/3/2018 Google Maps o ,;gIe Maps REVISIONS No changes shell he made to the scope ^'f W.C,4 ,,sithout prior approval of OtAcling Division. will require a new plan submittal rr:. y'nc ude additional plan review tees. r.. FILE C ;SPY Permit No. sb tS' 614Z. - Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt Thpy and conditions is acknowledged: 1. C11a_/ ��K �-seg - �- -� Y r J h..( 3-1 S ° a rov_p https://www.google.com/maps/@47.476332,-122.2770922, 78m/data=!3m1 ! 1 e3 Map data ©2018 Google 20 ft bL8Ol'I2. City of Tukwila JILDING DIVISION T. RTE PERMIT I-,EQUIRED FOR: l 1 echanical 2/Electrical (g/Plumbing i1BGas Piping City of Tukwila Buil DING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 0 22,3 City of Tukwila BUILDING DIV!3ION CORREC' ION LTR# RECEIVED CITY OF T UK` ILA JUN 0.7 2018 PERMIT CENTER 11/1/2018 City of Tukwila Department of Community Development OREN HADALLER 19238 39TH AVE S SEATAC, WA 98188 RE: Permit No. D18-0142 ST THOMAS CATHOLIC CHURCH 4415 S 140TH ST BLDG 1 Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 12/18/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 12/18/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: D18-0142 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 /'1 June 01, 2018 City of Tukwila Department of Community Development OREN HADALLER 19238 39TH AVE S SEATAC, WA 98188 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D18-0142 ST THOMAS CATHOLIC CHURCH - 4415 S 140TH ST BLDG 1 Dear OREN HADALLER, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x17 to a preferably maximum size of 24x36; all sheets shall be the same size; larger sizes may be negotiable. "New revised" plan sheets shall be the same size sheets as those previously submitted.) (BUILDING REVIEW NOTES) 1. The scope of work indicates installation of R11.4 insulation. Washington State Energy Code requires R-38 for flat or sloped frame roofs. Please verify to insure the roof shall meet energy code requirements for a total of R-38. Adjust as necessary in the scope of work provided. Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. Sincerely, RrAi Bill Rambo Permit Technician File No. D18-0142 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 IDERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0142 DATE: 06/07/18 PROJECT NAME: ST THOMAS CATHOLIC CHURCH SITE ADDRESS: 4415 S 140 ST Original Plan Submittal X Response to Correction Letter # 1 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: kr ASG (9449 Building Division II Fire Prevention Public Works U Structural n Planning Division nPermit Coordinator n • PRELIMINARY REVIEW: Not Applicable ri (no approval/review required) DATE: 06/12/18 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required n Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 07/10/18 0 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 CPERMIT CORD COPY C PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0142 DATE: 05/07/18 PROJECT NAME: ST. THOMAS CATHOLIC CHURCH SITE ADDRESS: 4415 S 140TH ST X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: HO A -V1 Acus. 5%) -SN' Fire Prevention Building Division Public Works Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 05/08/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: 06/05/18 ❑ Approved with Conditions Corrections Required (corrections entered in Reviews) Notation: Denied (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: Permit Center Use Only (0+18 ` � � � ,/w CORRECTION LETTER MAILED: � Departments issued corrections: Bldg Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. � X1201 Date: Plan Check/Permit Number: D18-0142 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: St Thomas Catholic Church Project Address: 4415 S 140 St Contact Person: P. -e a j4 /7-4' 'P Summary of Revision: RECEIVED CITY OF TUKWILA JUN 072018 PERMIT CENTER Phone Number: Z D 3/ 2 3 5 y // 2- Co re e..H.e�. 5 t1 s 14--t "-1‘1) Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in TRAKiT on Q�o/U7�6 C:\Users\bill-r\Desktop\Revision Submittal Form.doc Revised: August 2015 WASHINGTON BEST FINISHES I T r ._J Eiome Espanol Contact Safety & Health Claims & Insurance C) Washington State Department of Labor & Industries Search L&I Page 1 of 2 .A -Z Index Help My I,&I Workplace Rights Trades & Licensing WASHINGTON BEST FINISHES LLC Owner or tradesperson Principals ALVAREZ, ISRAEL, PARTNER/MEMBER Doing business as WASHINGTON BEST FINISHES LLC WA UBI No. 602 991 980 3702 West Valley Hwy. N. Suite #104 AUBURN, WA 98001 206-856-5286 KING County Business type Limited Liability Company [License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. WASHIBF890NK Effective — expiration 08/12/2011— 08/12/2019 Bond ........... State Farm Fire & Cas Co Bond account no. 98GD91018 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 08/12/2011 09/01/2010 Expiration date Until Canceled Insurance Nationwide Mutual Ins Co Policy no. ACPGL02565675462 $1,000,000.00 Received by L&I Effective date 05/07/2018 05/29/2018 Expiration date 05/29/2019 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602991980&LIC=WASHIBF890NK&SAW= 6/20/2018 Help us improve