HomeMy WebLinkAboutPermit D18-0164 - SABEY CORPORATION - REROOFSABEY CORPORATION" 3333 S 120 PL EXPIRED 12/23/18 D18-0164 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 1023049079 Permit Number: D18-0164 3333 S 120TH PL BLDG 3 Project Name: SABEY CORPORATION Issue Date: 6/22/2018 Permit Expires On: 12/19/2018 Owner: Name: Address: SABEY CORPORATION 12201 TUKWILA INTL BLVD 4TH FL , SEATTLE, WA, 98168 Contact Person: Name: JEREMY GWIMMER Address: Contractor: Name: Address: License No: Lender: Name: Address: 9420 29 AVE CT SW , LAKEWOOD, WA, 98499 MCDONALD & WETLE ROOFING INC 9420 39TH AVE CT SW , LAKEWOOD, WA, 98499-4412 MCDONWR944DW SABEY CORPORATION 12201 TUKWILA INTL BLVD 4TH FL , SEATTLE, WA, 98168 Phone: (253) 261-8673 Phone: (503) 667-0175 Expiration Date: 3/19/2020 DESCRIPTION OF WORK: TEAR OFF EXISTING BUR ROOF SYSTEM, INSTALL NEW FULLY ADHERED PVC ROOF SYSTEM WITH INSULATION. Project Valuation: $400,000.00 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $7,047.31 Occupancy per IBC: B Water District: 125,TUKWILA Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: fl 0 Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No gli41 Permit Center Authorized Signature: 61 W Date: Ula115 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. 5erf��r Signature: Print Name: Date: q01-9-71� This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: Prior to final inspection for this building permit, a copy of the roof membrane manufacturer's warranty certificate shall be provided to the building inspector. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0103 PRE-REROOF CITY OF TUKA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. 1 g O ((p U -1 Project No. Date Application Accepted: O '( 6 Date Application Expires: t \ �)--M ''( (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 3333 S 120th Place Tenant Name: Sabey Corporation PROPERTY OWNER Name: International Gateway East LLC Address: 12201 Tukwila International Blvd 4th Floor City: Seattle State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Jeremy Gwinner Address: 9420 29th Ave Ct SW City: Lakewood State: WA Zip: 98499 Phone: (253) 261-8673 Fax: (253) 589-9025 Email: jeremyg@mcdonaldwetle.com GENERAL CONTRACTOR INFORMATION Company Name: McDonald Wetle Roofing Inc Address: 9420 39th Ave Ct SW City: Lakewood State: WA Zip: 98499 Phone: (253) 589-8999 Fax: (253) 589-9025 Contr Reg No.: MCDONWR944L Exp Date: 03/19/2020 Tukwila Business License No.: BUS -0994319 H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docz Revised: August 2011 bh King Co Assessor's Tax No.: 1023049079 Suite Number: Floor: New Tenant: ❑ Yes ..No ARCHITECT OF RECORD Name: S.1iot..j Company Name: Architect Name: kl)t31 1,1 „„1) Address: City: m( City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Name: S.1iot..j Company Name: Engineer Name: kl)t31 1,1 „„1) Address: City: m( City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: S.1iot..j (vain+„tb Address: kl)t31 1,1 „„1) -Jr / e(v City: m( State: C/A. Zip: col 64 Page 1 of 4 LBUILDING PERMIT INFORMATIO206-431-3670 aluation of Project (contractor's bid price): $ 400,000 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): Tear-off existing BUR roof system, install new fully adhered PVC roof system with insulation. Will there be new rack storage? ❑ Yes No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Fonns-Applications On Line \2011 Applications\Pertoit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC In Floor 100,000 0 0 0 2nd Floor 3m Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Fonns-Applications On Line \2011 Applications\Pertoit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 06261 PERMIT APPLICATION NOTES — Now )'s'alue of Construction — hi all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR, THORIZE AGENTT. Signature: Date: 05/24/2018 Print Name: Jeremy iwinnef v Day Telephone: (253) 261-8673 Mailing Address: 9420 39th Ave Ct SW Lakewood WA 98499 H:\Applications\Forms-Applications On Line \2011 Applications\Pennit Application Revised - 8-9-11.docx Revised: August 2011 bh City State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT ( QUANTITY PermitTRAK ` PAID $7,047.31 D18-0164 Address: 3333 S 120TH PL BLDG 3 Apn: 1023049079 $7,047.31 DEVELOPMENT $6,840.17 PERMIT FEE R000.322.100.00.00 0.00 $4,142.83 PLAN CHECK FEE R000.345.830.00.00 0.00 $2,692.84 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $207.14 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R14570 R000.322.900.04.00 0.00 $207.14 $7,047.31 Date Paid: Thursday, May 24, 2018 Paid By: MCDONALD & WETLE ROOFING INC Pay Method: CHECK 5857 Printed: Thursday, May 24, 2018 11:31 AM 1 of 1 SYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pc L�� T4petof Inspec ' n: f Address: Date Called: Special Ins ructions_ OW krIAA- gild., -3 Date Wanted: 24 a.m. p.m. Requester: 34 Z/_ 5673 /V Approved per applicable codes. I`(� J Corrections required prior to approval. COMMENTS: Re -- S 180 cmV__ X-Ok, -tr;$ los-14 z-f-Afo-6 oc 3,311 1 JIS � ('/-.�g Inspector. St00 Date 2 — REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 0 t�r/Ft1 r SEP' ' ^ L L. iii d, y i_ �'��'e�Jl IT FIE-QLflh D FOR: Mechanical (� Iectncal (dumbing Lr Gas Piping City of Tukwila BU LFY � DIVISION AtL This set of construction documents shall he kept at the site of work and shall bet \i` Den to inspection by the Building Offici - or a duly authorized representative. City Of Tukwila BUILDING DIVISION N 0 Ca FILE C uFY N6— Olco'4- • Plan review approval is subject to errors and omissions) Approval of construction documents does no: cuthorize the violation of any adopted cede or ordinance. Receipt/ of approved Field Copy an conditions is acknowlcdgoc By: l°1// 4% Date: ria—d—/ii City of Tukwila BUILDING DIVISION FaScr_i{ DEr_y-.i— MATCla REVIEWED FOR CODE COMPLIANCE APPROVED JUN 21 2018 City of Tukwila BUILDING DIVISION a y % T.1 (U G )RE--CE-QED-- CITY OF TUKWILA JUN 122018 PERMIT CENTER CORREiT N DI(6-01k4 LT" This drawing bearing the Scott & From logo is a drawing developed by Scott & From Co., Inc., for its sole use on the listed project and is not to be distributed to and or used by any other party not having a contractual relationship with Scott & From on this project. Scale NTS Date 5-14-18 Material 24 Ga Pre Finished Scott & From Co., Inc. Sheet Metal Contractors 3820 South Junett Tacoma, WA 98409 Tacoma Seattle (253) 473-6644 (206) 878-7824 Field Verify All Measurements Drawn By MR Drawing Number k Project IGE Building 3 Reroof Exx5r t ru Co zry Cr l %�{ �2 5cC'J w/W nstiC2 2ti c .0 lam' A 1l Lel covealic,6 N Eva Roo c-S:nJG- •' i` e • REVIEWED FOR CODE COMPLIANCE APPROVED JUN 21 2018 CitritorTtandla BUILCVa DIVISION This drawing bearing the Scott & From logo is a drawing developed by Scott & From Co., Inc., for its sole use on the listed project and is not to be distributed to and or used by any other party not having a contractual relationship with Scott & From on this project. Scale NTS Date 5-14-18 Material 24 Ga Pre Finished Scott & From Co., Inc. Sheet Metal Contractors 3820 South Junett Tacoma, WA 98409 Tacoma Seattle (253) 473-6644 (206) 878-7824 Field Verify All Measurements Drawn By MR Drawing Number 1 I Project IGE Building 3 Reroof YV I rc 1-t Cy. REVIEWED FOR CODE COMPLIANCE PROVED JUN 21 2018 City of Tukwila BUILDING DIVISION This drawing bearing the Scott & From logo to be distributed to and or used by is a drawing developed by Scott & From Co., Inc., for its sole use any other party not having a contractual relationship with Scott & on the listed project and is not From on this project. Scale NTS Date 5-14-18 Material 24 Ga Pre Finished Scott & From Co., inc. Sheet Metal Contactors 3820 South Junett Tacoma, WA 98409 Tacoma Seattle (253) 473-6644 (206) 878-7824 Field Verify All Measurements Drawn By MR Drawing Number 3 Project IGE Building 3 Reroof AAkAo2. Cj,C• ti vir VII -1 I 0,1% y2. ScSca 614.3 V1`©.C. N ST.01(0_.,,T_ c zvr c o krL lZ. CMU REVIEWED FOR CODE COMPLIANCE APPROVED JUN 21 2018 City of Tukwila BUILDING DIVISION This drawing bearing the Scott & From logo is a drawing developed by Scott & From Co., Inc., for its sole use on the listed project and is not to be distributed to and or used by any other party not having a contractual relationship with Scott & From on this project. Scale NTS Scott & From Co., Inc. Sheet Metal Contractors 3820 South Junett Tacoma, WA 98409 Tacoma Seattle (253) 473-6644 (206) 878-7824 Field Verify All Measurements Drawn By MR Date • 5-14-18 Drawing Number LI _ Material 24 Ga Pre Finished Project IGE Building 3 Reroof Wt�_ t�wNCLST�,.t,, REVIEWED FOR CODE COMPLIANCE - -APPROVED-- JUN 21 2018 City of Tukwila BUILDING DIVISION This drawing bearing the Scott & From logo is a drawing developed by Scott & From Co., Inc., for its sole use to be distributed to and or used by any other party not having a contractual relationship with Scott & on the listed project and is not From on this project. Scale NTS Date 5-14-18 Material 24 Ga Pre Finished Scott & From Co., Inc. Sheet Metal Contractors 3820 South Junett Tacoma, WA 98409 Tacoma Seattle (253) 473-6644 (206) 878-7824 Field Verify All Measurements Drawn By MR Drawing Number Jf Project IGE Building 3 Reroof E .5rxiv& to ttit NEL 3 N w HEAD RA5 E 5a.t� r'1t:T��L MA 4_k5.5.v RC 6 20 C &trait/ (-HAT clam Vrei.e I t E i� Co ©• c - - - -It 4115- BU DIA/G— t3PF R 1 I!, 7.2 RTB S DTn1 (COD2. To 0I'TIC 6xt.s`C'liPC7) RSD C:,ry.rT n1 j' MCFAL ‘Aiteku, F, i')reS c�Ji Ct' REVIE D F'OR COOECO PLIAN E APP OVED JUN 21 2018 City of Tukwila BUILDING DIVISION This drawing bearing the Scott & From logo is a drawing developed by Scott & From Co., Inc., for its sole use on the listed project and is not to be distributed to and or used by any other party not having a contractual relationship with Scott & From on this project. Scale NTS Date 5-14-18 Material 24 Ga Pre Finished Scott & From Co., Inc. Sheet Metal Contractors 3820 South Junett Tacoma, WA 98409 Tacoma Seattle (253) 473-6644 (206) 878-7824 Field Verify All Measurements Drawn By MR Drawing Number b Project IGE Building 3 Reroof PVC- CLis,D C.o AT1O PAETI L SCARP C R- F V. REVIEWED FOR CODE COMPLIANCE —APPROVED— JUN 21 2018 City of Tukwila BUILDING DIVISION This drawing bearing the Scott & From logo is a drawing developed by Scott & From Co., inc., for its sole use to be distributed to and or used by any other party not having a contractual relationship with Scott & on the listed project and is not From on this project. Scale NTS Date 5-14-18 Material Scott & From Co., Inc. Sheet Metal Contractors 3820 South Junett Tacoma, WA 98409 Tacoma Seattle (253) 473-6644 (206) 878-7824 Field Verify All Measurements Drawn By MR Drawing Number 7 Project IGE Buildinq 3 Reroof 5" �a 1 U rvl h 7T—" 22. GA GI LV` ..__cotUTI.A1I AtJ5CLE i "......,.., 7.2c.1 `/z c 651{ERl F, r...i tviA4. tk i y P C. L _C._?�'1.� REVIEWED FOR CODE COMPLIANCE APPROVED JUN 21 2018 City of Tukwila BUILDING DIVISION This drawing bearing the Scott & From logo is a drawing developed by Scott & From Co., Inc., for its sole use on the listed project and is not to be distributed to and or used by any other party not having a contractual relationship with Scott & From on this project. Scale NTS Date 4-24-18 Material 24 Ga Pre Finished Scott & From -Co., Ince Sheet Metal Contractors 3820 South Junett Tacoma, WA 98409 Tacoma Seattle (253) 473-6644 (206) 878-7824 Field Verify All Measurements Drawn By MR Drawing Number 1 Project IGE Building 3 Reroof THE NRCA ROOFING MANUAL COPING • 24 GA. GALVANIZED STEEL • 22 GA. GALVANIZED STEEL CLEAT • CONTINUOUS FRONT FACE CLEAT AND GASKETED BACK FACE FASTENER ANSI/SPRI ES -1 TESTED RESISTANCE • . e UL -1A 8/1/12 OUTWARD UPWARD 190 LBS./SQ. FT. 310 LBS./SQ. FT. CONSTRUCTION DETAIL SM 2 5" MAX 135' 8„ MAX 24 GAUGE (0.024" THICK) GALVANIZED STEEL CONFORMING TO ASTM A653 3. 4 3" .1» 2 22 GAUGE (0.030" THICK) GALVANIZED STEEL CONFORMING TO ASTM A653 FABRICATION 14" CONTINUOUS CLEAT 1 1/4" LONG GALVANIZED STEEL ROOFING NAIL AT 6" O.C. CONTINUOUSLY HAND CRIMP HEM OVER CLEAT INSTALLATION COPING 1 1/2" LONG GALVANIZED STEEL HEX HEAD SCREW WITH WASHER AT 18" O.C. REVIEWED FOR CODE COMPLIANCE APPROVED JUN21 2013 City of Tukwila BUILDING DIVISION SAI1rBEY NORTHWEST ROOF CONSULTANTS, INC. FEEL INSTRUCTION TO BIDDERS To be considered, bids must be made in accordance with these instructions and specifications. 1. Receipt of Bids Sabey IGE 3 3333 South 120th Place Bids are to be mailed or hand delivered and must be received on or before: By end of work November 6, 2017 Bids submitted to: Sabey Corporation 12201 Tukwila Int'l Blvd. Fourth Floor Seattle, WA 98168 Ken Stickley (kens@sabey.com) REVIEWED FOR CODE COMPLIANCE APPROVED JUN 21 2018 City of Tukwila BUILDING DIVISION Bids must include a current letter from manufacturer stating contractor is approved to install the specified roofing and provide the 20 -year NDL Warranty 2. Inquiries All inquiries regarding the instructions or specifications are to be directed to: Ken Stickley Sabey Corporation Phone: 206 277 5230 RECEIVED CITY OF TUKWILA MAY 2 4 2018 PERMIT CENTER Page 12 3. Eligibility for Bid Submission 1. The bidder shall visit the site of work, and fully inform themselves as to all the existing conditions and limitations. 2. A bidder must be legally licensed to operate under applicable Washington state laws. 3. Although no performance bond is required for this job, the bidder must be bondable. 4. Bids may be submitted on the bidder's standard company bid form. 4. Successful Bidder Requirements 1. Prior to any work being performed, the successful bidder must provide the owner certificates of insurance for the following: Workers Compensation Comprehensive general liability naming owner as additional insured, covering bodily injuries, death and property damage with limits, as required by owner, from any one occurrence. 2. Insofar as possible, the successful bidder will employ such methods or means in his work that will not cause any interruptions of or interference with, the building use. 3. The contractor must comply with all Federal, State, City, and County laws and regulations that are applicable to the work being performed. 5. Specifications 1. Product Handling, Storage, and Delivery 1. Deliver materials to the project site in manufacturer's unopened, sealed containers or unopened packages, with the manufacturer's labels intact. 2. Deliver sufficient quantity of materials to allow continuity of work. 3. Store materials in weather protected environment, clear of the ground and moisture. 2. Job Conditions .PL_;1 ' 11 Begin', and continue, roof installation when weather conditions are within acceptable limits according to the manufacturer's installation instruction§. 1r' i Page 13 2. Restore to original condition or replace work or materials damaged during handling of roofing materials. 3. Protect paving and building walls. 4. Protect other work from spillage of roofing materials, and prevent materials from entering and clogging drains. 5. Replace or restore other work which is soiled or damaged by performance of the roofing and associated work. 6. Proceed only when installer is willing to guarantee the work as required, without additional reservations or restrictions. 7. Coordinate with other trades to make provisions for installation of their products which are a part of the roofing system and responsibility for coordinating installation of such items shall be an obligation under this section. 6. Scope of Work This is a Factory Mutual insured roof replacement. All roofing and sheet metal work must adhere to factory mutual requirements as per the attached Factory Mutual Plan Review. Specified material is Carlisle Sure -Flex PVC or Duro-Last. Roof system must be approved by Factory Mutual including all components of the system. It is the contractor's responsibility to insure all work is approved by and installed per Factory Mutual requirements. 1. Provide portable toilets for roofing crews. 2. Any subcontractors under roofing contractor must be union. Tear off and reroof: 1) Tear off all roofing and sheet metal and dispose of legally. 2) Remove all abandoned curbs and pipes and infill deck to match existing. Owner will identify. 3) Inspect the deck and replace any bad plywood. Include fifty sheets of plywood replacement in bid. If less than fifty sheets used credit owner at line item unit price. Provide unit price per sheet of plywood for replacement cost with the roof proposal. 4) Provide time and material rates with proposal for any additional work. Page 14 5) Build new parapet walls. Height of wall to be a minimum of 8 inches above the finished roof height. Wall to be fabricated from 2X6 standard or better, and half inch plywood. Top of wall to slope to interior. Walls will have to be fabricated to satisfy FM Standards. Carlisle Securedge 3000XT or 3000 on Securedge 300 Edgebox are acceptable for parapet construction. 6) Install 1/2 inch Dens -Deck or approved equal. 7) Over the 1/2 inch Dens -Deck install one layer of Carlisle 725TR self -adhering air/vapor barrier using Carlisle's most current details. 8) Install tapered insulation crickets to provide positive flow to drains. 9) Install two layers of Carlisle 4X8 Insulbase Polyiso 3.1 inch (R5.7 per 1 inch) 10) Install one-layer'/2 inch secureshield HD plus (R2.5). Mechanically attach through all layers of insulation as per FM requirements. 11) Install Carlisle 60 mil Sure flex PVC Gray, fully adhered to insulation with Carlisle Low VOC PVC Bonding Adhesive at a minimum rate of 1.55 gallons per square as recommended by the manufacturer. 12) Install base flashings as per manufacturer's most current instructions. 13) Install roof flashings in accordance with FM Global Property Loss Prevention Data Sheet I-49, Perimeter Flashing. 14) Install prepainted sheet metal flashings at perimeter of building as per FM requirements. Color to be selected by owner. Provide flashing down exterior of building past the existing paint line. Match metal to the adjacent building to the east. 15) Install new thru wall scuppers as per the manufacturer's requirements. 16) Clean up area upon completion. 17) Provide a total system 20 -year NDL warranty at completion of job. Alternate 1: Install Guardian Absorbinator Horizontal Lifeline system as per Guardian specifications. Use anchors that are a minimum of 8 inches above the finished roof. Plan Review Ken Stickley KenS@sabey.com Sabey Corporation Intergate East 12201 Tukwila International Blvd. Tukwila, WA., 98168 AFMM Member of the FM Global Group Index-Rec No: 078811.33-07 Account No: 23-33578 Date of Review: 5/31/2017 Review No: 250848 Plans Submitted By: Ken Stickley, Sabey Corporation, KenS@sabey.com Subject: Intergate East — Building 3 — Roofing Submittal Executive Summary: This submittal is in accordance with FM Global Standards subject to the installation recommendations noted below. Scope of Review: This confirms the receipt and review of: • Checklist For Roofing System • Email Correspondence — Roof Pullout Test dated March 29, 2017. The submittal details the re -roof of Building 3 at Intergate East. The new roof system will be installed on the existing wood roof deck. Fastener pullout test data has been completed with an average pull out resistance of 249 lbs. per fastener. The new roof system will consist of a Carlisle Sure -Flex PVC membrane fully adhered to two layers of Carlisle Insulbase insulation. The insulations will be mechanically fastened to the existing wood roof decking with Carlisle Insulfast fasteners. A Carlisle VapAir 725 vapor retarder will be provided beneath the insulation. The roof system is modeled from FM Global RoofNav Assemblies 343627-0-0 and 325911-0-0. The above is our understanding based on this and previous submittals. Please advise us if any of the above is inaccurate. Review Comments: 1. Ensure that the roof membrane is fully adhered to the roof system insulation layer with Carlisle Low VOC PVC Bonding Adhesive at a minimum application rate of 1.55 gallons per square. 2. Secure the roof insulation to the wood roof deck with eight (8) fasteners per 4 ft. by 8 ft. insulation board in the field and perimeter of the roof. 3. Secure the roof insulation to the wood roof deck with ten (10) fasteners per 4 ft. by 8 ft. insulation board in the corners of the roof. The roof corners are classified as an area that is 12 ft. by 12 ft. This report has been developed for insurance underwriting purposes. It is provided to you for informational purposes only to reduce the possibility of loss to insured property by bringing to your attention certain potential hazards or conditions. Life, safety, or health issues are not addressed. You must make the decision whether to take any action. The company undertakes no duty to you or any other party by providing this report or the activities on which it is based. The liability of the company is limited to that contained in its insurance policies. Page 2 of 2 Recommendations to Reduce Hazards during Installation: 4. Strictly manage and take proper precautions for hot work: a. Avoid hot work of any kind when possible. b. If there is a practical and safer way to do the job without hot work, use the alternative method. c. If hot work is unavoidable, use the FM Global Hot Work Permit System. Using the Hot Work Permit System and taking the precautions it requires prevents hot work fires. 5. Inspect the existing roof decking prior to beginning the roof installation. Damaged sections of the existing roof decking should be repaired or replaced prior to the installation of the new roof system. This review is for property insurance purposes only in accordance with FM Global standards and guidelines. Nothing should be inferred from this review regarding compliance with any rules, regulations or requirements of government agencies, state or local codes or any other jurisdictional authority. We are retaining the copy of your submitted plans for our files. Sincerely, Pete Vickers, P.E. Engineering Specialist ENGSanFranciscoPlanReview@fmglobal.com (925) 287-4336 Loss Prevention Resources: FM Global Property Loss Prevention Data Sheets (http://www.fmglobaldatasheets.com) FM Global Loss Prevention Training(https://fmglobaltraining.skillport.com) Approval Guide (http://www.approvalguide.com) RoofNav (http://roofnay.fmglobal.com) Distribution: Ken Stickley, Sabey Corporation, KenS@sabey.com Rod Butler, Sabey Corporation, RodB@sabey.com Richard Aasland, AFM, richard.aasland@affiliatedfm.com Ed Evatt, FM Global, Edward.evatt@finglobal.com Pete Vickers, FM Global, peter.vickers@finglobal.com This report has been developed for insurance underwriting purposes. It is provided to you for informational purposes only to reduce the possibility of loss to insured property by bringing to your attention certain potential hazards or conditions. Life, safety, or health issues are not addressed. You must make the decision whether to take any action. The company undertakes no duty to you or any other party by providing this report or the activities on which it is based. The liability of the company is limited to that contained in its insurance policies. NORTHWEST ROOF CONSULTANTS, INC. October 30, 2017 Sabey IGE 3 3333 1120th Place Addendum 1 Install sheet metal expansion joint as per SMCNA details at roof to wall where roof ties onto south wall. Provide line item cost to install sheet metal cladding to wall at south end of roof. Cladding to match existing and tie in at existing flashing. At joint on north section of roof between existing Firestone TPO membrane and BUR build separation curb per manufacturers details. Separation curb to be 15 feet south of existing TPO/BUR joint. Replace existing roof spec with the following: 6. Scope of Work This is a Factory Mutual insured roof replacement. All roofing and sheet metal work must adhere to factory mutual requirements as per the attached Factory Mutual Plan Review. Specified material is Carlisle Sure -Flex PVC or Duro-Last. Roof system must be approved by Factory Mutual including all components of the system. It is the contractor's responsibility to insure all work is approved by and installed per Factory Mutual requirements. 1. Provide portable toilets for roofing crews. 2. Any subcontractors under roofing contractor must be union. Tear off and reroof: 1) Tear off all roofing and sheet metal and dispose of legally. 2) Remove all abandoned curbs and pipes and infill deck to match existing. Owner will identify. 3) Inspect the deck and replace any bad plywood. Include fifty sheets of plywood replacement in bid. If less than fifty sheets used credit owner at line item unit price. Provide unit price per sheet of plywood for replacement cost with the roof proposal. 4) Provide time and material rates with proposal for any additional work. NORT!WEST ROOF CONSULTANTS, INC. 8680 Wayne Dr, Hayden Idaho 83835 (208) 772-8424 ph; (208) 772-8278 fax bcengineers STRUCTURAL -FORENSIC 5) Build new parapet walls. Height of wall to be a minimum of 8 inches above the finished roof height. Wall to be fabricated from 2X6 standard or better, and half inch plywood. Top of wall to slope to interior. Walls will have to be fabricated to satisfy FM Standards. Carlisle Securedge 3000XT or 3000 on Securedge 300 Edgebox are acceptable for parapet construction. 6) Install '/a inch Dens -Deck or approved equal. Fastening as per FM requirements. 8) Install tapered insulation crickets to provide positive flow to drains as per manufacturers requirements. 11) Install Carlisle 60 mil Sure flex PVC Gray, fully adhered to insulation with Carlisle Low VOC PVC Bonding Adhesive at a minimum rate of 1.55 gallons per square as recommended by the manufacturer. 12) Install base flashings as per manufacturer's most current instructions. 13) Install roof flashings in accordance with FM Global Property Loss Prevention Data Sheet I-49, Perimeter Flashing. 14) Install prepainted sheet metal flashings at perimeter of building as per FM requirements. Color to be selected by owner. Provide flashing down exterior of parapet to match existing. Match existing gauge of sheet metal flashings. 15) Install new thru wall scuppers as per the manufacturer's requirements. 16) Clean up area upon completion. 17) Provide a total system 20 -year NDL warranty at completion of job. This revised specification is being reviewed by FM. Owner will provide FM Nav number. Owner is reviewing the possibility of adding to the existing structure to increase weight requirements. Provide line item added cost to install original insulated specification. NORTHWEST ROOF CONSULTANTS, INC. 8680 Wayne Dr, Hayden Idaho 83835 (208) 772-8424 ph; (208) 772-8278 fax bcengineers STRUCTURAL -FORENSIC 1 Duro -Last PVC Roof System IFI CORREiTION 0v6, RECEIVED CITY OF TUKWILA JUN1 22018 PERMIT CENTER OP / / OP ODE COMPLIANCE APPROVED JUN 21 23;3 City of Tukwila UILDING DIVISION OP / i Duro-Tuff Light Gray 60 -Mil fully adhered Duro-Last WB II Water based adhesive #15 9" long fasteners and plates 1/4" Duro-Guard Securock Gypsum-Fibe 3.k3 Duro-Guard Poly - Iso insulation 3-3li 3.ti Duro-Guard Poly - Iso insulation / Duro-Last vapor barrier 4 / / self -adhered / #15 2" long fasteners / �eTfi**eTip►*e*e+e*+***ye+e*++='re�eT*******y*TTiiei�•iei*ieieieieieieieieieieiiiiiiiViiieNip" iei ?*e*e�eeee*e4.e*epee*pe*e*eee*e*eeee.'";:eee*e*e*e*e*e*e*eee*eeeeeee*eeeee4.gee+eeeeeei�eeeeieeeeei�e%'Oeei*OOOOeeeee00eee e4ei and plates %" Duro-Guard Securock Gypsum -Fiber Existing Wood Roof Deck McDonald & Wetle Roof System Description Sabey IGE 3 SIZE FSCM NO DWG NO REV SCALE 1:128 SHEET 3 OF 3 6 roof drains 3" pipe existing roof area (NIC) 1T P 1SUITE 100 ® 31,094SF Deck has - ructural slope NO WORK 12 MONTHS RESERVATION COLO 3 11,567 SF AVAILABLE COLO 1 15,728 SF TE ANT G CO°O2 12,65 SF SUITE 110 AVAILABLE SUITE 160 3,084 SF SUITE 180 Through -wall scupper 3"x6.5" UPS SUITE 1E3 2.322 SF COLO 4 AVAILABLE 3464 SF AVAILABLE OFFICE S311 SF FLOOR PLAN SCALE: 1(64" =1%0" 32' 64' 128' FIELD Through -wall scupper 3"x6.5" REVISIONS: Roof Replacement IGE-Building 3, Suite 110 6 180 Cricket profile 4.5" 6.5" REVIEWED FOR CODE COMPLIANCE APPROVED JUN 21 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 1 2 2018 PERMIT CENTER CORRECTION LTR# 1 P5- OUeL4 DATE: SCALE: 1164" 1' - 0" DRAWN: 11/1/2018 City of Tukwila Department of Community Development JEREMY GWIMMER 9420 29 AVE CT SW LAKEWOOD, WA 98499 RE: Permit No. D18-0164 SABEY CORPORATION 3333 S 120 PL Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 12/23/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 12/23/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: D18-0164 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 June 01, 2018 City of Tukwila Department of Community Development JEREMY GWIMMER 9420 29 AVE CT SW LAKEWOOD, WA 98499 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D18-0164 SABEY CORPORATION - 3333 S 120 PL Dear JEREMY GWIMMER, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x17 to a preferably maximum size of24x36; all sheets shall be the same size; larger sizes may be negotiable. "New revised" plan sheets shall be the same size sheets as those previously submitted.) "STAMP AND SIGNATURES" (If applicable) For Engineers: "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient (WAC 196-23-010 & 196-23-020). Architects: "date" only not required (WAC 308-12-081). (BUILDING REVIEW NOTES) 1. The roofing permit and plan indicates additional structural upgrades, new parapet walls, smoke hatch replacement, removal of under roof framing, seismic upgrades etc. For clarification indicate if an additional permit shall be provided with the specific documentation for the Landlord Scope of Work. Please specify if roof and structural work is combined by one contractor or if roofing shall be separate permit and contractor. Additional information plan details and documents with some clarification of all work shall be required to include plan details and specifications for all additional construction to this roof permit and or other permits. * Provide manufacturers specifications for the Carlisle Securedge 3000XT or what ever parapet materials proposed be installed with specific parapet construction details. * Provide specifications for flashings and scuppers and show scuppers sized for the design rain fall for this area. Identify on the roof plan where the scuppers are located and show roof slopes to scuppers and roof drains. * Provide roofing manufacturers specifications and installation information. * Provide engineered structural upgrade and alteration plans with details. * If the work is only intended for re -roof, only provide specific information and details for that work. Please clarify. 2. Landlord scope of work proposal is to remove 2 layers of GWB and framing. Verify this does not cause the building construction less hazardous or unprotected as previously built. Provide an analysis by a design professional or engineer to show areas affected and identify the use of those areas. Specify the building type of construction. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 0 3. All documentation produced by a design professional or engineer shall have stamp with signature on each plan sheet and documents. Engineer shall have stamp, signature and date of signature on all plan sheets and front of calculations. See General Notes above. Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. Sincerely, "D-zkP Bill Rambo Permit Technician File No. D18-0164 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 q'ERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0164 DATE: 06/15/18 PROJECT NAME: SABEY INTERGATE EAST BUILDING 3 SITE ADDRESS: 3333 S 120TH PL Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: PO MO 4/le Building Division Public Works Fire Prevention Structural n Planning Division Permit Coordinator n PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 06/19/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01/17/18 Approved ❑ Approved with Conditions n Corrections Required n Denied n (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping 0 PW 0 Staff Initials: 12/18/2013 c:PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0164 DATE: 05/24/18 ION Revision # before Permit Issued Revision # after Permit Issued PROJECT NAME: SABEY CORPORAT SITE ADDRESS: 3333 S 120 PL X Original Plan Submittal Response to Correction Letter # DEPARTMENTS: Building Division Public Works /N` AO' Fire Prevention II Structural Planning Division Permit Coordinator so PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 05/29/18 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 06/26/18 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: L-1-0 Departments issued corrections: Bldg 4, Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 Date: City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. d/�1 /fay ❑ Response to Incomplete Letter # Plan Check/Permit Number: ® Response to Correction Letter # 1 D18-0164 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # RECEIVED CITY OF TUKWILA JUN 122018 PERMIT CENTER Project Name: Sabey Intergate East Building 3 Project Address: 3333 S 120th PI Tukwila WA Contact Person: Jeremy Gwinner Phone Number: (253) 261-8673 Summary of Revision: -Updated plans with scupper and drain information -Clarification: Permit to cover re -roof and roof related sheet metal only. Structural work to be done by other contractor under separate permit -Attached submittals from sheet metal contractor including drawings of coping, flashing, and scuppers -Clarification: Mailing address is 9420 39th Ave Ct SW. not 29th Ave Ct SW. -Included system description detail with all layers of new roof system Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision p Received at the City of Tukwila Permit Center by:�/' "�'Wt \01(147) ❑ Entered in TRAKiT on W:1Permit Center\Templates\Forrts\Revision Submittal Formdoc Revised. August 2015 MCDONALD & WETLE ROOFINGGC Home Espanol Contact Safety & Health Claims & Insurance CWashington State Department of A Labor & Industries Search L&I Page 1 of 3 A -Z Index Help My Workplace Rights Trades & Licensing MCDONALD & WETLE ROOFING INC Owner or tradesperson Principals HAMBELTON, MARK D, CHIEF EXECUTIVE OFFICER HENRY, JEROMY, CHIEF EXECUTIVE OFFICER STARBUCK, GEORGE, CHIEF EXECUTIVE OFFICER CORCORAN, DANIEL J, CHIEF EXECUTIVE OFFICER NATIONALREGISTERED AGENTS INC, AGENT (End: 02/17/2016) BOLT, ROBERT E, PRESIDENT (End: 02/18/2010) HENDERSON, KENNETH W, VICE PRESIDENT (End: 02/18/2010) HENDERSON, KENNETH W, PRESIDENT (End: 02/18/2014) Doing business as MCDONALD & WETLE ROOFING INC WA UBI No. 602 576 757 9420 39TH AVE CT SW LAKEWOOD, WA 98499 503-667-0175 PIERCE County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ..................................................................... Meets current requirements. License specialties GENERAL License no. MCDONWR944DW Effective — expiration 03/16/2006— 03/19/2020 Bond .............. WESTERN SURETY CO Bond account no. 929491191 $12,000.00 Received by L&I Effective date 03/25/2010 03/02/2010 Expiration date Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602576757&LIC=MCDONWR944DW&SAW= 6/22/2018 MCDONALD & WETLE ROOFING INC Insurance ........................_ Continental Insurance Co Policy no. 5095022340 Until Canceled $1,000,000.00 Received by L&I Effective date 11/20/2017 11/24/2016 Expiration date 11/24/2018 Insurance history Savings ............. No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the tusiness has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 109,222-00 Doing business as MCDONALD & WETLE ROOFING INC Estimated workers reported Quarter 1 of Year 2018 "7 to 10 Workers" L&I account contact T1 / JAN BENTLEY (360)902-4652 - Email: STR0235@Ini.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes ........ ................... No strikes have been issued against this contractor. Contractors not ahowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 10/08/2015 Inspection no. 317938077 Location 23600 Marine Vicw Dr. S Des Moines, WA 98198 Inspection results date 07/01/2013 Inspection no. 316772045 Location 8825 Rainier Ave S Seattle, WA 98118 No violations No violations Page 2 of 3 Help us improve ©Washington State Dept. of Labor & industries. Use of this site is subject to the laws of the state of Washington. https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602576757&LIC=MCDONWR944DW&SAW= 6/22/2018