Loading...
HomeMy WebLinkAboutPermit D18-0165 - AMC THEATER 16 - 4 KIOSKS AND SIGNSAMC SOUTHCENTER 16 3600 SOUTHCENTER MALL D18-0165 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov DEVELOPMENT PERMIT 9202470010 3600 SOUTHCENTER MALL Project Name: AMC THEATER 16 Permit Number: D18-0165 Issue Date: 7/10/2018 Permit Expires On: 1/6/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD, WA, 92013 HENG LIU PO BOX 53445 , BELLEVUE, WA, 98015 PROGRESSIVE FLOORING SRVCS INC 100 HERITAGE DR, PATASKALA, OH, 43062 PROGRFS855N1 Lender: Name: AMC THEATERS Address: ONE AMC WAY, 11500 ASH ST , LEAWOOD, KS, 66211 Phone: (206) 886-1350 Phone: (614) 868-9005 Expiration Date: 8/20/2019 DESCRIPTION OF WORK: REMOVE 4 SELF-SERVING TICKET KIOSKS/SIGNS, REMOVE COUNTERTOP SECURITY GRILL, SHORTEH TICKET COUNTER, ADD A PARTITION WALL AND A DOOR. Project Valuation: $20,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: IIB Electrical Service Provided by: TUKWILA Fees Collected: $865.97 Occupancy per IBC: A-1 Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: f1 Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 Permit Center Authorized Signature: Date: / 0-1 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulaf g construction or the performance of work. I am authorized to sign and obtain this development permit a d a ee . the conditions attached to this permit. Signature: Print Name: Date:F-7/1071g,2 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 16: TO SCHEDULE ALL FIRE INSPECTIONS CALL 206-575-4407. 9: An approved automatic fire sprinkler extinguishing system is required for this project. (City Ordinance #2436) 10: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 13: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 12: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 11: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 14: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 15: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING 0502 LATH/GYPSUM BOARD CITY OF TUKTA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Pert No. � t Project No. Date Application Accepted: Date Application Expires: 11 —,-S' ' t (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** Site Address: Southcenter Mall Tenant Name: AMC Southcenter 16 King Co Assessor's Tax No.: 920247-0010 Suite Number: 3600 Floor: PROPERTY OWNER Name: Westfield Address: 4905 Old Orchard Center, Suite 060 City: Skokie State: IL Zip: 60077 CONTACT PERSON — person receiving all project communication Name: Same as Architect Architect Name: Heng Liu Company Name: N/A Address: Address: City: Bellevue State: WA City: State: Zip: Phone: Fax: Zip: Email: Fax: Phone: GENERAL CONTRACTOR INFORMATION Company Name: TBD Architect Name: Heng Liu Company Name: N/A Address: PO Box 53445 Address: City: Bellevue State: WA Zip: 98015 Phone: (206) 886-1350 Fax: City: State: Zip: Phone: Fax: Phone: Fax: Contr Reg No.: Email: Exp Date: Tukwila Business License No.: H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh New Tenant: ❑ Yes ARCHITECT OF RECORD Company Name: Pacific Studio Architecture Architect Name: Heng Liu Company Name: N/A Address: PO Box 53445 City: Bellevue State: WA Zip: 98015 Phone: (206) 886-1350 Fax: Address: Email: liu@psa-design.net ENGINEER OF RECORD Name: AMC Theaters Address: One AMC Way, 11500 Ash St. Company Name: N/A Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: AMC Theaters Address: One AMC Way, 11500 Ash St. City: Leawood State: KS Zip: 66211 Page 1 of 4 BUILDING PERMIT INFORMATIOl206-431-3670 Valuation of Project (contractor's bid price): $ 20,000 Describe the scope of work (please provide detailed information): Remove 4 self-serving ticket kiosks/signs, remove countertop security grille, shorten ticket counter, add a partition wall and a door. Existing Building Valuation: $ Will there be new rack storage? ❑ Yes E.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to ` Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1't Floor 2nd Floor 3rd Floor 70,825 210 II -B A-1 Floors thru Basement Accessory Structure*` Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFOCATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑ ...Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate ❑ .. Highline ❑...Valley View ❑ .. Renton ❑ ...Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑ ...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours 0 .. Right-of-way Use — Potential Disturbance 0 .. Work in Flood Zone 0 .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut 0 .. Looped Fire Line 13 ❑ .. Grease Interceptor ❑ .. Channelization 0 .. Trench Excavation 0 .. Utility Undergrounding ❑ ...Permanent Water Meter Size... 35 WO # ❑ ...Temporary Water Meter Size .. WO # ❑ ...Water Only Meter Size WO # ❑ ...Deduct Water Meter Size 0 ...Sewer Main Extension Public ❑ Private 0 0 ...Water Main Extension Public ❑ Private 0 FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) 0 ...Water 0 ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip H \Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE? OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature:Date: 05/25/2018 Print Name: Heng Liu Day Telephone: (206) 886-1350 Mailing Address: PO Box 53445 Bellevue WA 98015 City State Zip H:\Applications\Forms-Applications On Line \2011 Applicalions\Permil Application Revised - 8-9-11 .docx Revised: August 2011 bh Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK I ACCOUNT I QUANTITY PAID $536.64 D18-0165 Address: 3600 SOUTHCENTER MALL Apn: 9202470010 $536.64 Credit Card Fee $15.63 Credit Card Fee R000.369.908.00.00 0.00 $15.63 DEVELOPMENT $496.41 PERMIT FEE R000.322.100.00.00 0.00 $491.91 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $24.60 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R14896 R000.322.900.04.00 0.00 $24.60 $536.64 Date Paid: Tuesday, July 10, 2018 Paid By: HENG LIU Pay Method: CREDIT CARD 01147G Printed: Tuesday, July 10, 2018 11:43 AM 1 of 1 CRSYSTEMS CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 07/10/2018 11:42:22 AM CREDIT CARD SALE VISA CARD NUMBER: **********4962 K TRAN AMOUNT: $536.64 APPROVAL CD: 01147G RECORD #: 000 CLERK ID: Bill Thank you! Customer Copy Page 2 of 2 https://classic.convergepay.com/VirtualMerchant/transaction.do?dispatchMethod=printTra... 7/1 0/201 8 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $329.33 D18-0165 Address: 3600 SOUTHCENTER MALL Apn: 9202470010 $329.33 Credit Card Fee $9.59 Credit Card Fee R000 369.908 00.00 0.00 $9.59 DEVELOPMENT $319.74 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R14573 R000.345.830.00.00 0.00 $319.74 $329.33 Date Paid: Friday, May 25, 2018 Paid By: KENG LIU Pay Method: CREDIT CARD 07890G Printed: Friday, May 25, 2018 8:47 AM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 6o a Project: Mc viWc&z - ii Type of Inspection: <4.66,14 74'1- - Address:��//_ 3L7 6d'Cb' er ��L&- I A Date Called: -- Special Instructions: Date Wanted: Z—ZiZol, a. Requester: Phone No: cgiApproved per applicable codes. 0 Corrections required prior to approval. COMMENTS: 7g Inspector: Date 20!, ins ection, fee must REINSPECTION FEE REQUIRED. Prior to nextbe paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit 2v orbs -- PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: � � � C +I� 7y ap Type of Inspection: 43 /'- bi A.4' Ad ress: 3(400 ? 41*-- Date Called: Special Instructions: ✓C eel( PA /..-;, ie # 2O Date Wanted: a.m. Requester: Phone No: ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: )/14 l q " iz p'Z'A.Pre r� LJ -, , n• 44) /;,-(-• AIS L Date: -20/7._ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit Di3 of* PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, T .. - ' • 188 (206) 431-3670 Permit Inspection Request Li Project: Ar4e- xvrll rr&. /b Type of Inspection: Q?xhittA/G .A' i*— Address:``'' 3 4mrrft(�ree__ meta. Date Called: � Special Instruct'ons: �.z.-17.167 � 7 Z53 5�j— 73 /y Date Wanted: �x mV p.m. Requester: 6 Phone No: 6,(t £1-3 e341 ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: 3 4ail4 A No Jam, "-e/1°� m)/ dr joIe,vis OAC • Inspector: La Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: rrt Sei Type o Inspec&on: Address: Mr-4a— Date Called: Special Instructions: Date Wanted: 7 �'� a.m. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: lt)a-ct hee,kid *toe/ di= Inspector: Date: 72_7...7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: /�MC` SQw Type o Inspection: eg Address: 34 ao ., ,rifek-- VW L : • • 1aa 0� Special Instructions: AMC, Sou I-kker-Aer # l& Date W. ted: . "'t - ?Q- p.m. Requester: Phon o: 37-775-/337 ElApproved per applicable codes. COMMENTS: orrections 111101 uired prior t A f fe•-o-td-- royal. Alfg 0 Date: 262- ^ �� REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 12/2/2018 City of Tukwila Department of Community Development HENG LIU PO BOX 53445 BELLEVUE, WA 98015 RE: Permit No. D18-0165 AMC THEATER 16 3600 SOUTHCVENTER MALL Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 1/19/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 1/19/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, actiel e"Ripley Permit Technician File No: D18-0165 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0165 DATE: 05/25/18 PROJECT NAME: AMC SOUTHCENTER 16 SITE ADDRESS: 3600 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: Building Division It liePublic Work 41 4\4 Fire Prevention Structural Planning Division nPermit Coordinator r PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 05/29/18 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved DUE DATE: 06/26/18 ❑ Approved with Conditions ❑ Corrections Required (corrections entered in Reviews) Denied (ie: Zoning Issues) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 PROGRESSIVE FLOORING SRVCNC Home Espanol Contact Safety & Health Claims & Insurance 41111) Washington State Department of Labor & Industries Page 1 of 2 Search L&I A-1, Index help My I &I Workplace Rights Trades & Licensing PROGRESSIVE FLOORING SRVCS INC Owner or tradesperson Principals SOUTH, RICHARD J, PRESIDENT CERVI, NINO A, VICE PRESIDENT CERVI, MIA M, SECRETARY Doing business as PROGRESSIVE FLOORING SRVCS INC WA UBI No. 603 528 684 100 HERITAGE DR PATASKALA, 01-1 43062 614-868-9005 Business type Corporation Governing persons RICHARD A SOUTH MIA M CERVI; NINO A CERVI; License Verify the contractors active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. PROGRFS855N1 Effective — expiration 08/20/2015— 08/20/2019 Bond ................ Nationwide Mutual Ins Co Bond account no. 7900431250 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 08/20/2015 08/18/2015 Expiration date Until Canceled Insurance ...................... NATIONWIDE PROPERTY AND CASUAL $1,000,000.00 Policy no. ACPGLK05712556958 Received by L&I Effective date 05/30/2018 05/20/2018 Expiration date 05/20/2019 Insurance history Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603528684&LIC=PROGRFS855N1&SAW= 7/10/2018 PROGRESSIVE : LOORING SRVcC,tINC Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations Infraction no. NSLOD00847 Issue date 09/09/2015 Violation city PATASKALA Type of violation CONSTRUCTION INFRACTION Description Advertising, offering to do work, submitting a bid or performing work when not registered as a contractor, as required. Satisfied ...................... RC WNUAC 18.27.200(1)(a) RCW Violation amount $500.00 Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 568,050-00 .............................. Doing business as PROGRESSIVE FLOORING SERVICES Estimated workers reported Quarter 1 of Year 2018 "0" Workers L&I account contact T5 / MELISSA VEST (360)902-5613 - Email: VESM235@lni.wa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes ...._............................_.................. No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 Olt Washington State Dept of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603528684&LIC=PROGRFS855N 1 &SAW= 7/10/2018 TENANT IMPROVEMENT 3600 SOUTHCENTER MALL, TUKWILA, WA 98188 GENERAL NOTES 1. ALL WORK SHALL BE PERFORMED AS TO FULLY COMPLY WITH LEGAL, INDUSTRY AND PROJECT -SPECIFIC REQUIREMENTS AND THE FOLLOWING STANDARDS: A. ALL APPLICABLE BUILDING CODES B. ALL APPLICABLE SPECIAL CODES C. THE PROJECT DOCUMENTS AND SPECIFICATIONS D. THE MANUFACTURES STANDARDS AND REQUIREMENTS E. THE LANDLORD'S BUILDING STANDARDS 2. IN USING THIS DOCUMENT FOR BIDDING AND CONSTRUCTION PURPOSES, CONTRACTORS ARE REQUIRED TO REVIEW IN ITS ENTIRETY IN ORDER TO IDENTIFY ALL REQUIREMENTS THAT DIRECTLY OR INDIRECTLY AFFECT THEIR WORK, THE INTENT IS TO INCLUDE ALL LABOR, MATERIALS, PRODUCTS AND SERVICES NECESSARY FOR COMPLETING THE PROJECT AS CALLED FOR BY THIS DOCUMENT. IN CASE OF CONFLICTS OR OMISSIONS, THE CONTRACTOR SHALL EITHER OBTAIN DIRECTION FROM THE OWNER, OR APPLY THE MORE STRINGENT STANDARDS. 3. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF WORK. NOTIFY THE OWNER IF ANY DISCREPANCY IS FOUND. 4. ALL DIMENSIONS OF EXISTING CONDITIONS ARE APPROXIMATE AND ARE SUBJECT TO FIELD VERIFICATIONS. 5. DO NOT MEASURE DRAWINGS TO OBTAIN DIMENSIONS, WRITTEN DIMENSIONS GOVERN. ALL DIMENSIONS SHOWN ARE TO: - FACE OF EXISTING FINISHES - FACE OF FRAMING OR SHEATH INC - FACE OF CONCRETE OR MASONRY WALLS - CENTERLINE OF COLUMNS - CENTERLINE OF WINDOWS OR DOORS 6. IN USING THIS DOCUMENT, THE FOLLOWING RULES APPLY: A. WRITTEN DIMENSIONS GOVERN. B. SPECIFIC NOTES AND DETAILS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND STANDARD DETAILS. C. WORK NOT SPECIFICALLY SHOWN SHALL BE THE SAME AS THOSE SHOWN AND SPECIFIED. D. "NIC" IS FOR REFERENCE ONLY AND THE RESPONSIBILITY OF THE CONTRACTOR SHALL NOT BE LIMITED FOR PROTECTION OR COORDINATION BY THIS DESIGNATION. THIS DOCUMENT IS INTENDED TO REPRESENT ONLY THE FINISHED CONSTRUCTION. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR MEANS, METHODS, SEQUENCES AND PROCEDURES DURING CONSTRUCTION, AND SHALL INDEMNIFY TO THE FULLEST EXTEND ALLOWED BY LAW THE PROJECT TEAM FROM AGAINST ALL RELATED CLAIMS AND LIABILITIES. THIS DOCUMENT IS INTENDED FOR CONSTRUCTION IN STANDARD LEVEL OF QUALITY AND DETAIL. ERRORS AND OMISSIONS ARE EXPECTED AND CONTRACTORS SHALL REVIEW PLANS CAREFULLY AND NOTIFY THE PROJECT TEAM FOR ANY SUCH ERROR AND OMISSION. 10. NO DEVIATION FROM THE REQUIREMENTS OF THIS DOCUMENT ARE ALLOWED WITHOUT EXPRESS AUTHORIZATION FROM THE OWNER. THE CONTRACTOR ASSUMES FULL RESPONSIBILITY OF SUCH DEVIATION. 11. SUBSTITUTION REQUEST WILL ONLY BE CONSIDERED IF THE PROPOSED SUBSTITUTION CONSTITUTES AN EQUAL OR IMPROVED QUALITY TO THE OWNER, AND IN NO EVENT THAT THE OWNER IS REQUIRED TO AUTHORIZE ANY SUBSTITUTION. 12. AT THE CONCLUSION OF THE CONSTRUCTION, THE CONTRACTOR SHALL PROVIDE A WRITTEN CERTIFICATION THAT THE CONSTRUCTION HAS BEEN PERFORMED IN COMPLIANCE WITH THE APPROVED PROJECT PLANS AND SPECIFICATIONS, AS THE BUILDING OFFICIAL MAY REQUIRE OR THE OWNER MAY REQUEST. JOBSITE NOTES 1. THE CONTRACT SHALL MINIMIZE CONSTRUCTION NOISE TO THE ADJACENT TENANTS OR BUSINESSES AND PROVIDE THEM WITH PROPERLY NOTICE PRIOR TO WORK. 2. THE CONTRACTOR, AT THIS OWN EXPENSES, SHALL KEEP THE PROJECT AND SURROUNDING AREA FREE FROM DUST AND DEBRIS. THE WORK SHALL BE IN CONFORMANCE WITH THE CLEAN AIR AND WATER STANDARDS AND REGULATIONS. 3. THE CONTRACTOR SHALL PROPERLY DISPOSE DEBRIS AND WATERS FROM THE PROJECT SITE AND NOTIFY BUILDING AUTHORITY OF THE DISPOSAL SITE. 4. NO HAZARDOUS MATERIALS SHALL BE USED OR STORED WITHIN THE BUILDING WHICH DOES NOT COMPLY WITH THE LOCAL FIRE AUTHORITY AND OTHER REQUIREMENTS. 5. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE OCCUPANTS AND WORKERS AT ALL TIMES. THE CONTRACTOR SHALL PROVIDE PEDESTRIAN PROTECTION WHERE REQUIRED PER STATE AND LOCAL CODES. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE BUILDING AND THE SITE WHILE JOB IS IN PROGRESS AND UNTIL THE JOB IS COMPLETED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CLOCKING OFF SUPPLY AND RETURN AIR GRILLES, DIFFUSERS AND DUCTS TO KEEP DUST FROM ENTERING INTO BUILDING AIR DISTRIBUTION SYSTEMS. 9. WHERE ELECTRICAL, MECHANICAL AND/OR PLUMBING ITEMS, SUCH AS LIGHT FIXTURES, PLUMBING FIXTURES, DUCTS, PIPES, ETC. ARE TO PENETRATE BUILDING STRUCTURES, IT'S REQUIRED THAT AN APPROPRIATE OPENING OR CLEARANCE BE FURNISHED. THE CONTRACTOR SHALL COORDINATE THE INSTALLATION OF THESE ITEMS WITH CONSTRUCTION DOCUMENTS PRIOR TO WORK AND NOTIFY PROJECT TEAM OF ANY CONFLICT. 10. THE CONTRACTOR SHALL LOCATE AND PROVIDE ACCESS DOORS/PANELS IN WALLS AND CEILINGS AS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SPRINKLER SYSTEMS. THESE LOCATIONS SHALL BE MARKED ON THE PLANS FOR ARCHITECT'S APPROVAL PRIOR TO WORK. 11. ALL PENETRATION AT RATED CONSTRUCTION SHALL BE PROTECTED TO MAINTAIN THE RATING. 12. ALL NEW CONSTRUCTION MATERIALS SHALL BE QUALITY MATERIALS OF 100% ASBESTOS FREE. 13. INTERIOR WALLS AND CEILINGS SHALL BE INSTALLED IN ACCORDANCE WITH STATE AND LOCAL CODES, INCLUDING REQUIREMENTS FOR FLAME SPREAD AND SMOKE DENSITY RATING FOR FINISH MATERIALS. 14. THE CONTRACTOR IS RESPONSIBLE FOR THE GENERAL CLEANING OF THE JOBSITE, INCLUDING EXTERIOR AND INTERIOR OF THE BUILDING, THE PATH OF TRAVEL TO THE JOBSITE, PARKING LOTS, ELEVATORS, LOBBIES, AND CORRIDORS, AFTER PROJECT COMPLETION. PROPERTY INFORMATION PARCEL NUMBER: 920247-0010 LEGAL DESCRIPTION: WEA SOUTHCENTER LLC BSIP PER BSIP REC VOL 256 PGS 1-9 WHICH REPLACES BSIP REC VOL 249 PGS 77-84 (AKA PARCEL A TUKWILA BSIP #L10-032 REC #20101021000765) SITE ADDRESS: SOUTHCENTER MALL POSTAL CITY: TUKWILA, WA 98188 CURRENT USE: SHOPPING MALL PROPERTY OWNER: WESTFIELD SHOPPING CENTER SCOPE OF WORK 1. REMOVE 4 SELF-SERVICE TICKET KIOSKS WITH SIGNS. 2. REMOVE COUNTERTOP SECURITY GRILLE SYSTEM. 3. SHORTEN SERVICE COUNTER WITH A 40" PASS THROUGH. 4. ADD 6' X 8' PARTITION WALL WITH A 3' X 7' DOOR. CODE REGULATIONS WASHINGTON STATE BUILDING CODE, WHICH INCLUDES THE FOLLOWING WITH WASHINGTON STATE AMENDMENTS: - 2015 INTERNATIONAL BUILDING CODE - 2015 INTERNATIONAL MECHANICAL CODE - 2015 INTERNATIONAL FIRE CODE - 2015 INTERNATIONAL FUEL GAS CODE - 2015 UNIFORM PLUMBING CODE - 2017 NATIONAL ELECTRIC CODE WASHINGTON STATE ENERGY CODE WASHINGTON STATE INDOOR AIR QUALITY CODE PROJECT TEAM LANDLORD: WESTFIELD 4905 OLD ORCHARD CENTER, SUITE 060, SKOKIE, IL 60077 TEL. 847-779-4832 TENANT: AMC SOUTHCENTER 16 3600 SOUTHCENTER MALL, TUKWILA, WA 98188 TEL. 206-214-0180 ARCHITECT: PACIFIC STUDIO ARCHITECTURE, LLC PO BOX 53445, BELLEVUE, WA 98015 TEL. 206-886-1350 SHEET INDEX A1.1 PROJECT INFO l SITE PLAN A1.2 REFERENCE OVERALL FLOOR PLAN A2.1 FLOOR PLAN/ ELEVATIONS / DETAILS OTHER SUBMITTALS THE CITY OF TUKWILA MAY REQUIRE MECHANICAL, ELECTRICAL, PLUMBING, FIRE PROTECTION AND OTHER PERMITS AND THESE PERMITS WILL BE SUBMITTED SEPARATELY. BUILDING SUMMARY THE PROJECT AREA IS LOCATED ON THE THIRD FLOOR OF A FOUR STORY BUILDING. THE BUILDING AREA OF THE THIRD FLOOR IS 70,825 SF AND THE PROJECT AREA IS APPROXIMATELY 210 SF. TYPE OF CONSTRUCTION: II -B FULLY SPRINKLED OCCUPANCY GROUP: A-1 (MOTION PICTURE THEATERS) VICINITY MAP SCALE: NO SCALE REVISIONS No changes shall h' made to the scope of work without prior approval of Tukw^ !a Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees 1 TUKWILA PKWY Vir 11, i•iiii'iiiiiiiiiii' ii°•000°O°O°i•�� •e•°°•sOs° At- °°°°4 • • PROJECT AREA STRANDER BLVD NORTH SITE PLAN erN SCALE: NO SCALE411 8- DI AMC SOUTHCENTER TENANT IMPROVEMENT 3600 SOUTHCENTER MALL TUKWILA, WA 98188 I SEPARATE PERMIT REQUIRED FOR: I.�E' echanicai • (2 Electrical C�.'PIumbing L`� Gas Piping C ty of Tukwila I~ iVISi0N raL %>i:til Y Permit No. D15 -DVA Flan review az :lrod 13 subjoct to errors and omissions. Approval of const► uct:on documonts does not authorize the violation of any adopt!. d code or ordinance. Receipt o' approved Field Cop; 4nditidns is acknowledged: RECEIVED CITY OF TUKWILA_ MAY 252E10 PERMIT CENTER— By: Date: -7 9-c City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED JUN 11 2018 RP' City of Tukwila BUILDING DIVISION PACIFIC STUDIO ARCHITECTURE LLC 14015 SE 61ST PL BELLEVUE, WA 98006 206-886-1350 HENG LIU, ARCHITECT WA STATE # 9283 i7 REGISTERED .,RCHITECT HENG QIAN LIU STATE OF WASHINGTON DATE 04/10/18 05/16/18 05/25/18 DESCRIPTION PRELIMINARY REVIEW LANDLORD REVIEW PERMIT SUBMITTAL 5 2018 -AMC PM: HQL A1.1 (TYP) (TYP) (TYP) 1 Ir 299 SEATS A 5 EXIT /:%.%••••,.................., QJfiirlit t� +�i�r5i■i■i■i■i5tioko�� *" .....41.4.1.pAir° ,111i!•i■i■i■,10,01111 �.' �� -z-,114,iii.:- ® �• � �. +moi.• �... - - ..I 220 SEATS AUDITORIUM #11 220 SEATS yy—��71C�—t[71 0-71 ICy�—t!�71Cyy��71 �� Mix Mai hCiM AO OA 11,11. . 1, ,�......, ,1111i NAI i■i■i■i■i■i■i■i■i■i■i■i■i■i■i■i■i r.w.w w w.w,wiw.ww-waw w-.w�w�ww w� i■i■i■i■i■i■i■i■i11i■UUi■i■i■i11i■i■i■i11i■i ,011•111/1,1010 ...WNW NIP WI 111,11101411110111014r, I l i l l f I 1 I I I 1 I 14 I 1 fi�r�r•1:1tk/'s1110•,r t , l I If' FIL:11111 .111 :MU A A 1.1111111111111111111,110,-,.�... A#13E)I'FD i■i111I i■i■i■1 s�r��wiwr�r -imam �w111111,rre i■i■i■i■i■i■i■i■i■i■i■i■i■i■i■i■i■i■i■i■i■i■i■i rlOW 1WW., 4M OW IMO OW IOW Iwr:OWOW.OW1 WO lnlliw 11111 OW MONO i■i■i■7i■i MAI l ARM' w.r.A Nowt. :,o•w OW OW WWI i■i■i11i■i■i■jUi•i■i■i■i■i■i■i■i i■i■i■i■11111 W rill AEA i■i■i■ N1.1111■i■WO i■i i■i■i■i■i■i■i■i■i■i■i■i■i■i■i■i■i■i■i■i■i 111•111 NM/ MI I ell ..n..MIEN. w waw w .1.1•111 OMNI i11i1111111i11illi1111i11i1111111i1111i•i iUi0iIiUiS!IiIiRi i i i i i i Ai 1 i i i i i i i■i i■i i i WOMEN- IC OMEN 11:17III`JI "---,11, SECURE STORAGE Mtn 17%(/ L/1.....-'1,,,' •j L: `JL' "J CONCESSICiI .a o la :JINN - eLe3-1618414os n 1111 LOSET I ,00000 n SUP RAMP1:13 A #14 EXIT 0 y\\ O\\ O\\ •% 4\1 011 •\ 0a O1\ o\l 4A OA OM X111 X111 1 OA OM 11110 al all 60 all al all ID alt 61 all all 5) 1 ill •0 all II MI sii sl a,) I1 ait ■Ir ai al all ID ai 11 ?a11 sir O 1 II00 OW OH 5I 5,; !ill 44 aI 44 *l1 491 1110 EXIT STAIR 318 ROTUNDA CORRIDOR LOBBY CORRIDOR ROTUNDA r-----US_®®m®®®®MEIN 1 • 1 1/* 1/* 1/ IG` I* 0,41l4 //ij l4 i(s tlir tis fir (15 Ili /lir IA lta VII 115 tai Ilii rra (5 Ili Ilii Ili la II! (15 115 15 00 11. 11• M■ 110 115 110 Is 0 11* ll!! N_! 110 110 w0 10 110 0 00 10 110 11!I! l\0 %0 110 a0 1\0 10 SA IL 309A 1 Ir�l�1�,lEalr� EXIT. STAIR A #7ENT. -- -- —lhlm ow um mIwI�1-1 I—I-- -- w — um mei �,■.■.■.1111.1111■.■■.1111.■■11■^■•■.■►■i■1■!■!Ili co 111.11111111111111 NM NMI= MI NOM MIMI MI MI 1/01 MI IN NO MN MAN 0011111111=1 M.= 1111.1?■!■!■!■!■!■?■!■!11!■?■!■!11!11!■!■1111■!■!■!■111111!>• 11111.0101111101111111.111111111118111101800.011110 0111111111111111111.1. _ce—M Iall= MI M— 11111111111 h--- .111111,0111 Ai 11111 IMAM �i■'■,■■■■'■11■'■11■■■f■l■■■1I■'■' ■■1M 111111111=1 !...�..MIN Y[ ins— __•_, V[. wn�•ow no = 11!11111!11!11! MIM !U!.1111N111!11! MI !/I?■!■ S!M A #15 ENT. (TYP) �t fi.0 Aviv 401 PP:air r„ 111!11!11!■!11111t11100'/ A ; 7 EXIT A #8 ENT 1 1 111 1 11 11 11 11 1 1 ,:-.1141014,140,11114184,,--. vial alai 1• Is In I5 le 1! I5 I■ (TYP) A #16 ENT. A #15 EXIT ®®®MEIN (TYP OF 4) PROJECT AREA (TYP) Ji IL RECEIVED CIT` OF TUKWILA REFERENCE FLOOR PLAN SCALE: NO SCALE NORTH -MAY 25 2018. PERMIT CENTE DISCLAIMER THE OVERALL FLOOR PLAN WAS CREATED BY USING "RECORD DRAWING" FROM THE ORIGINAL BUILDING DESIGN DOCUMENTS. PACIFIC STUDIO ARCHITECT WAS NOT THE ORIGINAL BUILDING DESIGN ARCHITECT AND DID NOT VERIFY THE ACCURACY OF THIS DOCUMENT. R AMC SOUTHCENTER TENANT IMPROVEMENT 3600 SOUTHCENTER MALL TUKWILA, WA 98188 REVIEWED FOR CODE COMPLIANCE APPROVED JUN 11 2018 City of Tukwila BUILDING DIVISION PACIFIC STUDIO ARCHITECTURE LLC 14015 SE 61ST PL BELLEVUE, WA 98006 206-886-1350 HENG LIU, ARCHITECT WA STATE # 9283 REGISTERED cRCHITECT HENG QIAN LIU STATE OF WASHINGTON DATE 04/10/18 05/16/18 05/25/18 DESCRIPTION PRELIMINARY REVIEW LANDLORD REVIEW PERMIT SUBMITTAL 2018 -AMC PM: HQL A1.2 AUDITORIUM (EXIST.) JWAK MOW' 1;XX L --J REMOVE EXISTING ABOS AND SIGN ON WALL, PATCH / REPAIR WALL AND BASE WITH MATCHING MATERIALS AS NEEDED, TYP. OF (4) CUT AND REMOVE EXISTING COUNTER NEW TILE FINISH MATCH & LEVEL WITH EXISTING PROVIDE END PANEL FINISH MATCH EXISTING PLEXIGLASS BOX OFFICE (EXISTING) RELOCATE EXISTING SWITCHES AND CONTROLS FROM BOX OFFICE TO GUEST SERVICES NEW DOOR REMOVE EXISTING SECURITY GRILLE AND TRACK, PATCH / REPAIR CEILING AS NEEDED GUEST SERVICES (EXISTING) MALL SPACE (EXISTING) INFILL WALL MATCH EXISTING AT SIDES OF THE GRILLE BOX OFFICE FLOOR PLAN SCALE: 1/4" = 1'-0" r I L r 7 L J ///A REMOVE EXISTING TICKET SIGN ON WALL, PATCH AND REPAIR WALLAS NEEDED REMOVE EXISTING ABOS, TYP. OF (4) BOX OFFICE ELEVATION r-- SCALE: 1/4" =11-0" r L 1 J INFILL GRILLE POCKET WITH NEW WALL MATCH EXISTING, TYP. BOTH SIDES BO XO (EXISTI FFICE NG) S 1 NEW TILE BASE MATCH EXISTING, TYP. CUT AND REMOVE 40" WIDE EXISTING COUNTER, PROVIDE PLEXIGLASS END PANEL MATCH EXISTING E GUEST RVICE EXISTING) S n \ v RELOCATE EXISTING SWITCHES AND CONTROLS ON THIS WALL NEW 3'0" X 613" STEEL DOOR IN KNOCK DOWN FRAME WITH KEY PAD PASSAGE KNOB SET NEW WALL AND BASE MATCH EXISTING LINE OF EXISTING / NEW WALLS DOOR HARDWARE (3) HINGES (1) KNOB SET (1) DOOR STOP (1) OVERHEAD CLOSER DOOR NOTE 1. DOOR HANDLES, PULLS OR KNOBS SHALL BE INSTALLED AT 40" ABOVE THE FINISHED FLOOR. ALL OTHER OPERABLE PARTS OF DOOR HARDWARE SUCH AS DEADBOLTS, KEYHOLES, ETC. ARE TO BE CENTERED BETWEEN 34" AND 44" ABOVE FINISHED FLOOR. 2. DOOR FRAMES TO BE FACTORY FINISHED. PARTIAL ELEVATION SCALE: 1/4" = 1'-0" LEGEND EXIST. WALL TO REMAIN EXIST. WALL TO REMOVE NEW WALL A EXIST. DOOR TO REMAIN NEW DOOR NEW TILE FINISH MATCH EXISTING MALL FLOOR TILE GROUT SCHLUTER TRANSITION STRIP EXISTING CARPET IN BOX OFFICE EXISTING CONC. FLOOR reA1111111111111111111111111111111111111111 • • A DETAILS 4 SCALE: 6" = 1'-0" EXIST. GWB CEILING DOUBLE TRACK TO ALLOW VERTICAL MOVEMENT 5/8" GYP. BD. OVER 3 5/8" METAL STUDS @16" O.C. FASTEN RUNNER TO EXIST. CONC. FLOOR 4" RUBBER BASE, TYP. BOTH SIDES TO MATCH EXIST. EXIST. CONC. FLOOR DETAIL SCALE: 2" = 1'-0" RECEIVED CITY OF TUKWILA MAY 252018 PERMIT CENTER OWS AMC SOUTHCENTER TENANT IMPROVEMENT 3600 SOUTHCENTER MALL TUKWILA, WA 98188 REVIEWED FOR CODE COMPLIANCE APPROVED JUN 11 2018 City of Tukwila BUILDING DIVISION PACIFIC STUDIO ARCHITECTURE LLC 14015 SE 61ST PL BELLEVUE, WA 98006 206-886-1350 HENG LIU, ARCHITECT WA STATE # 9283 REGISTERED .(RCHITECT HENG QIAN LIU STATE OF WASHINGTON DATE 04/10/18 05/16/18 05/25/18 DESCRIPTION PRELIMINARY REVIEW LANDLORD REVIEW PERMIT SUBMITTAL 2018 -AMC PM: HQL A2.1