HomeMy WebLinkAboutPermit D18-0168 - SEGALE PROPERTIES - MEMBRANESEGALE PROPERTIES
300 ANDOVER PARK W
D18-0168
Parcel No:
Address:
0
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
DEVELOPMENT PERMIT
2623049001 Permit Number: D18-0168
300 ANDOVER PARK W COMPLEX Issue Date: 6/1/2018
Permit Expires On: 11/28/2018
Project Name: SEGALE PROPERTIES
Owner:
Name: SEGALE PROPERTIES LLC
Address: PO BOX 88028 , TUKWILA, WA, 98138
Contact Person:
Name: CURTIS CAMPISTEGUY
Address: PO BOX 88028 , TUKWILA, WA, 98138
Contractor:
Name; SEGALE PROPERTIES LLC
Address: PO BOX 88028 , TUKWILA, WA, 98138
License No: SEGALPL902CQ
Lender:
Name: SEGALE PROPERTIES LLC
Address: PO BOX 88028 , TUKWILA, WA, 98138
Phone: (206) 396-2016
Phone: (206) 575-2000
Expiration Date: 5/1/2020
DESCRIPTION OF WORK:
ADD SECOND PLY MEMBRANE OVER EXISTING SINGLE PLY MEMBRANE
Project Valuation: $230,263.00
Type of Fire Protection: Sprinklers:
Fire Alarm:
Type of Construction: VB
Electrical Service Provided by: TUKWILA
Fees Collected: $4,556.42
Occupancy per IBC: M
Water District: TUKWILA
Sewer District: TUKWILA
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
2015
2015
2015
2015
2015
National Electrical Code:
WA Cities Electrical Code:
WAC 296-46B:
WA State Energy Code:
2017
2017
2017
2015
Public Works Activities:
Channelization/Striping:
Curb Cut/Access/Sidewalk:
Fire Loop Hydrant:
Flood Control Zone:
Hauling/Oversize Load:
Land Altering: Volumes: Cut: 0 Fill: 0
Landscape Irrigation:
Sanitary Side Sewer: Number: 0
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter: No
Permit Center Authorized Signature: Date:
1,0214e_
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction: or the performance of work. I am authorized to sign and obtain this
development permit and e to th ondiiti• s attached to this permit.
Signature:
Print Name:
L.,' a'ri-sNj
Date: 6/I /'
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***BUILDING PERMIT CONDITIONS***
2: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
3: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
4: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector based
on satisfactory completion of this requirement.
6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
8: Prior to final inspection for this building permit, a copy of the roof membrane manufacturer's warranty
certificate shall be provided to the building inspector.
9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the City
of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
0 o
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1700 BUILDING FINAL**
0103 PRE-REROOF
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Building Permit No. b( 6 -016g
Project No.
Date Application Accepted:
Date Application Expires:
l� -U-(i3
(For office use only)
CONSTRUCTION PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
King Co Assessor's Tax No.: 2623049001
Site Address: 300 Andover Park W
Tenant Name: Segale Properties LLC
Suite Number:
PROPERTY OWNER
Name: Curtis Campisteguy
Address: P 0 Box 88028
Name: Segale Properties LLC
Phone: Fax:
206-575-2000
City: Tukwila State: WA
Address: P 0 Box 88028
Phone: 206-396-2016 Fax:
Phone: 206-973-5423 Fax:
City: Tukwila State: WA
Zip:
98138
CONTACT PERSON — person receiving all project
communication
Name: Curtis Campisteguy
Address: P 0 Box 88028
Address: P 0 Box 88028
Phone: Fax:
206-575-2000
City: Tukwila State: WA
Zip: 98138
Phone: 206-396-2016 Fax:
Phone: 206-973-5423 Fax:
Email: curtisc@segaleproperties.com
Email: dalek@engineersNW.com
GENERAL CONTRACTOR INFORMATION
Company Name: Segale Properties LLC
Address: P 0 Box 88028
City: Tukwila State: WA Zip: 98138
Phone: Fax:
206-575-2000
Contr Reg No.: SEGALPL902CQ Exp Date: 5-1-2020
Tukwila Business License No.: BUS -0101320
H:\Applications\Fmms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx
Revised: August 2011
bh
Floor:
New Tenant: 0 Yes ..No
ARCHITECT OF RECORD
Company Name: Engineers Northwest Inc., P.S.
Engineer Name: Dale Kaemingk
Company Name:
N/A
City: Seattle State: WA
Architect Name:
Phone: 206-973-5423 Fax:
Email: dalek@engineersNW.com
Address:
City:
State:
Zip:
Phone:
Fax:
Email:
ENGINEER OF RECORD
Company Name: Engineers Northwest Inc., P.S.
Engineer Name: Dale Kaemingk
City: •TUk t,,,,(4/ c State: `4/:I Zip: "1 m
Address: 9725 Third Avenue NE
City: Seattle State: WA
Zip: 98115
Phone: 206-973-5423 Fax:
Email: dalek@engineersNW.com
LENDER/BOND ISSUED (required for projects $5,000 or
greater per RCW 19.27.095)
Name: Self Funded 1C LI 1'e_ ewer -Pt -I-
/
Address: S gl/ 54 is j r�C djl,_ (-
City: •TUk t,,,,(4/ c State: `4/:I Zip: "1 m
Page 1 of 4
BUILDING PERMIT INFORMATION — 206-431-3670
Valuation of Project (contractor's bid price): $ 230,263.00
Describe the scope of work (please provide detailed information):
Add second ply membrane over existing single ply membrane.
Will there be new rack storage? ❑ Yes
Existing Building Valuation: $
®.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard:
Compact: Handicap:
Will there be a change in use? ❑ Yes ❑ No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications\Foims-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx
Revised: August 2011
bh
Page 2 of 4
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
lat Floor
112,251
2'id Floor
3rd Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard:
Compact: Handicap:
Will there be a change in use? ❑ Yes ❑ No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications\Foims-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx
Revised: August 2011
bh
Page 2 of 4
PERMIT APPLICATION NOTES —
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING O7O
Signature:
Print Name:
RIED AGENT:
Curtis J. Campisteguy
Mailing Address: PO Box 88028
H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx
Revised: August 2011
bh
Date: 5-29-2018
Day Telephone: 206-396-2016
Tukwila WA 98138
City State Zip
Page 4 of 4
Cash Register Receipt
City of Tukwila
DESCRIPTIONS ACCOUNT QUANTITY
PermitTRAK
I PAID
$4,556.42
D18-0168 Address: 300 ANDOVER PARK W COMPLEX Apn: 2623049001
$4,556.42
DEVELOPMENT
$4,422.54
PERMIT FEE
R000.322.100.00.00
0.00
$2,677.60
PLAN CHECK FEE
R000.345.830.00.00
0.00
$1,740.44
WASHINGTON STATE SURCHARGE
B640.237.114
0.00
$4.50
TECHNOLOGY FEE
$133.88
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R14611
R000.322.900.04.00
0.00
$133.88
$4,556.42
Date Paid: Wednesday, May 30, 2018
Paid By: SEGALE PROPERTIES LLC
Pay Method: CHECK 645387
Printed: Wednesday, May 30, 2018 11:36 AM 1 of 1
CRWYSTEMS
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
Permit Inspection Request Line (206) 438-9350
Dvi5 oa-
jil
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-
Project:�,.�,,�
.3E6 e(20-Pj11��"3G
Type of Inspection:
-IR r.2 Ai—
Address:Date
3Q19 AN�I/.�t, PAA4A - I/J
Called:
Special Instructions:
0e-0ooe
Date Wanted: c .m,.
3-"l1 -I`? p.m.
Requester:
G.) -r,
Phone No:
'(m 39 (o 2occ'
Approved per applicable codes. El Corrections required prior to approval.
OMMENTS:
as1/4)67,
ARG
Inspector:
Date: ‘10\
n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be ti
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
D1F�-x168'
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project:
e. it_Vl-►
App
of Ins ion:
Pre- e Role
Add:
3CVA0c6iteP4AC
Date Called.
Special Instructions:
‘---PI M
Date Wanted: m.
Requester: S
Phone No: 2o& -34,-2.D/6
/ -
Approved per applicable codes.
orrections required prior to approval.
COMMENTS:
Reoc 1e45 L dJ
L ettitpc n
�
i `
PJekSc (c — Cat l I vs w
P.aar lg ✓�.Qy fes✓
Over Cry,
Inspector: ....01)(-1..a,
Date:/ 7 zy/
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
NWSTRLJCTURAt.
ENGINEERS
Engineers Northwest Inc., P.S.
April 5, 2018
SEGALE PROPERTIES
5811 Segale Park Drive C
Tukwila, WA 98188
Attn: Steve Nelson
r
Re: Segale Retail Center — Tukwila, WA
300 Andover Park West
Roof Membrane Addition
Steve,
LU
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 01 2018
BUILDof Tukwila
NG DIVISION
It is my understanding that you are anticipating a roof repair for Segale Retail Center at
300 Andover Park West, Tukwila, WA. As you know, this building, built in 1993, has a
steel framed roof structure with a single ply roof system.
understand you will be adding a new 60 mil T.P.O. membrane that weighs only about
one pound per square foot.
Section 707.2 of the 2015 International Building Code allows for a 5% increase in the
dead Toad on the roof without requiring modification to the original structural members. As
you are effectively adding very little dead load on the roof, it is my opinion that the
existing roof structure is adequate to support the new roof membrane addition.
Please feel free to call if you have any questions.
Sincerely,
ENGINEERS f .Of7HWEST, INC., P.S.
•. A
Dale KaemingkP.E., S.
Principal
DK:bs
ENW Job No.
CITY OF TUKWILA
MAY 302018
PERMIT CENTER
bt8O(8
Engineers Northwest, Inc., P.S. • Structural Engineers • 9725 Third Avenue NE • Seattle, WA 98115 • 206.973.5423 • fax 206.522.6698
C4RLIHLE:
April 5, 2018
Stafani Christian
Rainbow Federal, Inc.
PO Box 1116
Carnation, WA 98014
Re: Segale Retail
To Whom It May Concern:
flLU
This letter is to acknowledge the UL Fire Classification with the Segale Retail project. The existing Hypalon roof system is
as follows;
Deck:
Insulation:
Membrane:
Steel Deck.
Polyisocyanurate insulation (R-19).
Hypalon membrane mechanically attached to the deck.
The proposed recover includes installing Carlisle's 60 -mil Sure -Weld TPO membrane mechanically attached directly over
the existing Hypalon roof system.
The existing UL Fire Classification will be maintained up to a %2" in 12" slope.
If you have any questions or require additional information, please contact our office.
Sinceerely,
sot fir el7U,ex/'
Brandon M. Maag
Design Analyst
Carlisle SynTec Systems
Cc; S. Silcock — Harper Winn, Inc.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUN 01 2018
1
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
MAY 30 2018
PERMIT CENTER
bt�-oi6e
P.0. Bat 7003 Carsas!e, PA 17013 Pharr:800.470.6832 Fax 717.245.7053 www.cart,le-svrtec.cmn
TRANSMITTAL OF SHOP DRAWINGS, EQUIPMENT DATA, MATERIAL SAMPLES, OR MANUFACTURER'S
CERTIFICATES OF COMPLIANCE
SECTION 1 - REQUEST FOR APPROVAL OF THE FOLLOWING ITEMS (This section
will be initiated by the contractor)
3/29/2018
TRANSMITTAL #: 1
Segale Properties
18205 Andover Park West
Tukwila, WA 98188
FROM:
Rainbow Federal, Inc.
P.O. Box 1116
Carnation, WA 98014
rILE
Project Title & Location: Segale Retail
300 Andover Park West
Tukwila, WA 98188
CHECK ONE:
X THIS IS A NEW TRANSMITTAL
THIS IS A RESUBMITTAL OF
TRANSMITTAL
CONTRACT#:
ITEM
NO.
DESCRIPTION OF ITEM SUBMITTED
MFG. OR CONTR.
CAT., CURVE
DRAWING OR
FRnrl-II IRF Nn
NO. OF
COPIES
CONTRACT REFERENCE
DOCUMENT
SPEC. DRAWING
PARA, NO. SHEET NO.
a.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
b.
c.
d.
e.
f.
FOR
CONTRAC
TOR USE
r .nni
VARIATION
g.
h.
Carlisle Approve Applicator Letter
20 -year Total System Warranty
Letter
1
Sample
1
Sure -Weld TPO Membrane (60 mil for horizontal and 45 mil for vertical)
Data
1
Fasteners and Plates
Data
1
Non -Reinforced Membrane
Data
1
Bonding Adhesive - for vertical applications
Cut Edge Sealant
Data
1
Data
1
TPO Clad Metal - for scupper fabrication
Pipe Boots
Data
1
Data
1
Inside Corners
Outside Corners
T -Joint Covers
REVIEWED FOR
Data
1
CODE COMPLIANCE-.
Cleaner
APPROVED
Data
1
Data
1
Data
1
CITY ROF TUKWIL.A
MAY 30 2018
Water Cut Off Mastic
JUN 01 2018
Data
1
Walkpad
Data
1
PERMIT CENTER
REMARKS:
City of Tukwila
BUILDING fIVISiON
Stefani Christian
NAME AND SIGNATURE OF CONTRACTOR
ENCLOSURES RETURNED (List by Item number)
SECTION 11 - APPROVAL ACTION
NAME, TITLE AND SIGNAT OF APPROVING AU ITY
4rr1M+
C4RLISLE
March 29, 2018
Rainbow Federal, Inc.
P.O. Box 1116
Carnation, WA 98014
Project: Segale Retail
Attn: Steve Nelson,
1
Customer#: 203146
This letter is to confirm that Rainbow Federal, Inc. of Carnation, WA
has been a Carlisle Authorized Applicator in good standing since
1998.
Since becoming an Authorized Applicator, Rainbow Federal, Inc. has
installed 97 warranted projects totaling over 5.5mm square feet.
Please feel free to contact me should you have any further questions.
Sincerely,
qac Paeoft
Ryan Paxton
North West District Sales Manager
PJ 6a7C"� far, FA 17013 PT -7n= CC3 4/ 6x.32 Fax 457r53 wrrrca:it:`e-:imec.ct.
CARLISLE )+00/1
6o�N Sou TOTALROOFING SYsrEM Waiii�Y
SERIAL NO.
DATE OF ISSUE:
BUILDING OWNER:
NAME OF BUILDING:
BUILDING ADDRESS:
DATE OF COMPLETION OF THE CARLISLE TOTAL ROOFING SYSTEM:
DATE OF ACCEPTANCE BY CARLISLE:
Carlisle Roofing Systems, Inc., (Carlisle) warrants to the Building Owner (Owner) of the above described building, that; subject to the terms,
conditions, and limitations stated in this warranty, Carlisle will repair any leak in the Carlisle Golden SeaP Total Roofing System (Carlisle Total
Roofing System) installed by a Carlisle Authorized Roofing applicator for a period of20years commencing with the date of Carlisle's acceptance
of the Carlisle Total Roofing System installation. However, in no event shall Carlisle's obligations extend beyond years subsequent to the date
of substantial completion of the Carlisle Total Roofing System. See below for exact date of warranty expiration.
The Carlisle Total Roofing System is defined as the following Carlisle brand materials: Membrane, Flashings, Adhesives and Sealants, Insulation,
Cover Boards, Fasteners, Fastener Plates, Fastening Bars, Metal Work, Insulation Adhesives, and any other Carlisle brand products utilized in this
installation.
TERMS, CONDITIONS, LIMITATIONS
1. Owner shall provide Carlisle with written notice via letter, fax or email within thirty (30) days of the discovery of any leak in the Carlisle Total Roofing System. Owner should send
written notice of a leak to Carlisle's Warranty Services Department at the address set forth at the bottom of this warranty. By so notifying Carlisle, the Owner authorizes Carlisle
or its designee to investigate the cause of the leak. Should the investigation reveal the cause of the leak to be outside the scope of this Warranty, investigation and repair costs
for this service shall be paid by the Owner.
2. If, upon inspection, Carlisle determines that the leak is caused by a defect in the Carlisle Total Roofing System's materials, or workmanship of the Carlisle Authorized Roofing
Applicator in installing the same, Owner's remedies and Carlisle's liability shall be limited to Carlisle's repair of the leak.
3. This warranty shall not be applicable if, upon Carlisle's inspection, Carlisle determines that any of the following has occurred:
(a) The Cadiste Total Roofing System is damaged by natural disasters, including, but not limited to, lightning, fire, insect infestations, earthquake, tornado, hail, hurricanes,
and winds of (3 second) peak gust speeds of mph or higher measured at 10 meters above ground; or
(b) Loss of integrity of the building envelope and, or structure including, but not limited to partial or complete loss of roof decking, wall siding, windows, doors or other
envelope components or from roof damage by wind-blown objects, or.
(c) The Carlisle Total Roofing System is damaged by any intentional or negligent acts, accidents, misuse, abuse, vandalism, civil disobedience, or the like.
(d) Deterioration or failure of building components, including, but not limited to, the roof substrate, walls, mortar, HVAC units, non -Carlisle brand metal work, etc., occurs and
causes a leak, or otherwise damages the Cadiste Total Roofing System; or
(e) Acids, oils, harmful chemicals and the like come in contact with the Carlisle Total Roofing System and cause a leak, or otherwise damage the Carlisle Total Roofing
System.
(t) The Carlisle Total Roofing System encounters leaks or is otherwise damaged by condensation resulting from any condition within the building that may generate moisture.
4. This Warranty shall be null and void if any of the following shall occur.
(a) If, after installation of the Carlisle Total Roofing System by a Carlisle Authorized Roofing Applicator there are any alterations or repairs made on or through the roof or
objects such as, but not limited to, structures, fixtures, solar panels, wind turbines, root gardens or utilities are placed upon or attached to the roof without first obtaining
written authorization from Carlisle; or
(b) Faiture by the Owner to use reasonable care in maintaining the roof, said maintenance to include, but not be limited to, those items listed on Carlisle's Care &
Maintenance Information sheet which accompanies this Warranty.
5. Only Carlisle brand insulation products are covered by this warranty. Carlisle specifically disclaims liability, under any theory of law, for damages sustained by or caused by non -
Carlisle brand insulation products.
6. During the term of this Warranty, Carlisle shall have free access to the roof during regular business hours.
7. Carlisle shall have no obligation under this Warranty white any bills for installation, supplies, service, and warranty charges have not been paid in full to the Carlisle Authorized
Roofing Applicator, Carlisle, or material suppliers.
8. Carlisle's failure at any time to enforce any of the terms or conditions stated herein shall not be construed to be a waiver of such provision.
9. Carlisle shall not be responsible for the cleanliness or discoloration of the Carlisle Total Roofing System caused by environmental conditions including, but not limited to, dirt,
pollutants, or biological agents.
10. Carlisle shall have no liability under any theory of law for any claims, repairs, restoration, or other damages including, but not limited to, consequential or incidental damages
relating, directly or indirectly, to the presence of any irritants, contaminants, vapors, fumes, molds, fungi, bacteria, spores, mycotoxins, or the like in the building or in the air,
land, or water serving the building.
11. This warranty shall be transferable upon a change in ownership of the building when the owner has completed certain procedures including a transfer fee and an inspection of
the Roofing System by a Carlisle representative.
CARLISLE DOES NOT WARRANT PRODUCTS UTILIZED IN THIS INSTALLATION WHICH IT HAS NOT FURNISHED; AND SPECIFICALLY DISCLAIMS
LIABILITY, UNDER ANY THEORY OF LAW, ARISING OUT OF THE INSTALLATION AND PERFORMANCE OF, OR DAMAGES SUSTAINED BY OR CAUSED BY,
PRODUCTS NOT FURNISHED BY CARLISLE OR THE PRIOR EXISTING ROOFING MATERIAL OVER WHICH THE CARLISLE ROOFING SYSTEM HAS BEEN
INSTALLED
THE REMEDIES STATED HEREIN ARE THE SOLE AND EXCLUSIVE REMEDIES FOR FAILURE OF THE CARLISLE TOTAL ROOFING SYSTEM OR ITS
COMPONENTS. THERE ARE NO WARRANTIES EITHER EXPRESSED OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A
PARTICULAR PURPOSE AND MERCHANTABILITY, WHICH EXTEND BEYOND THE FACE HEREOF. CARLISLE SHALL NOT BE LIABLE FOR ANY
INCIDENTAL, CONSEQUENTIAL OR OTHER DAMAGES INCLUDING, BUT NOT LIMITED TO, LOSS OF PROFITS OR DAMAGE TO THE BUILDING OR ITS
CONTENTS UNDER ANY THEORY OF LAW.
BY: Robert H. McNeill
AUTHORIZED SIGNATURE
TITLE: Director. Technical and Warranty Services
This Warranty Expires:
P 0, floc 7000 Gat lcxte PA 1 413 Phone. 800.273,9551 Fax: 717.245 7121 Www carne tesvnti c corn
WA -F0001 Nth)
EXPERIENCE THE CARLISLE DIFFERENCE
Sure-WeldTPO
Reinforced Membrane
Overview
Carlisle's Sure -Weld TPO reinforced membrane is a premium, heat -
weldable, single -ply Thermoplastic polyolefin (TPO) sheet designed for new
roof construction and re -roofing applications. Sure -Weld High Slope (HS)
membrane is formulated with additional flame retardant for higher -slope
fire code approvals. Sure -Weld EXTRA is 80 mils thick for significantly
higher strength and weatherability.
Sure -Weld TPO membranes use advanced polymerization technology
that combines the flexibility of ethylene -propylene (EP) rubber with the
heat weldability of polypropylene. All Sure -Weld TPO membranes include
OctaGuard XT"", an industry-leading, state-of-the-art weathering package.
OctaGuard XT technology enables Sure -Weld TPO to withstand the extreme
weatherability testing that is intended to simulate exposure to severe climates.
Physical properties of the membrane are enhanced by a strong polyester
fabric that is encapsulated between the TPO-based top and bottom plies.
The combination of the fabric and TPO plies provides high breaking and
tearing strength, as well as excellent puncture resistance. The relatively
smooth surface of the membrane produces a total surface fusion weld
that results in a consistent, watertight, monolithic roof assembly. The
membrane is environmentally friendly and safe to install.
Carlisle's standard and HS TPO membranes are available in highly reflective
white, tan, and gray, in both 45 -mil and 60 -mil thicknesses. 80 -mil
Sure -Weld EXTRA (including HS) is also offered in white, gray, and tan colors.
Special color Sure -Weld TPO membranes are also available (see Carlisle's
TPO Color Palette brochure). Carlisle's TPO is offered in 4-, and 6 -ft
perimeter sheets and 8-,10-, and 12 -ft Sure -Weld field sheets. Sure -Weld
HS and special color TPO membranes are available in limited sizes.
Carlisle's tan and white TPO membranes are ENERGY STAR®* -qualified and
California Title 24 compliant and can contribute toward LEED® (Leadership
in Energy and Environmental Design) credits.
CARLISLE
SYNTEC SYSTE
Productivity Boosting Features and Benefits:
Optional APEEL Protective Film
Carlisle's Sure -Weld TPO reinforced membrane is
available with an optional APEEL Protective Film,
saving time and labor by eliminating the need for
roof cleaning upon project completion. Carlisle's
innovative APEEL Protective Film can be left in
place for up to 90 days without affecting the
integrity of the film, guarding the TPO membrane's surface from scuffs
and dirt accumulation during installation. Durable and easy to remove,
APEEL Protective Film improves aesthetics and long-term reflectivity
and is ideal for re -roofing, re-cover, and new construction projects.
OCTRGURRO XT
WEATHERING PACKAGE
Features and Benefits
» Outstanding puncture resistance
» Excellent fire resistant assemblies
» Environmentally friendly and stable formulation
» Excellent resistance to impact and low temperatures
» Excellent chemical resistance to acids, bases and restaurant exhaust
emissions
» UL 2218 Class 4 hail rating
» Exceptional resistance to heat, solar UV, ozone and oxidation
»
Manufactured using a hot -melt extrusion process for complete scrim
encapsulation
» 100% recyclable (see Carlisle's Recyclability Statement)
Enhanced with the OctaGuard XT weathering package
» APEEL Protective Film application guards the TPO membrane's
surface from scuffs and dirt accumulation during installation,
improving the roof system's appearance and long-term performance
• APEEL Protective Film can be left in place for up to 90 days without
degrading due to its excellent heat- and UV -resistance
800-479-6832 1 P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 1 www.cartislesyntec.com
EXPERIENCE THE CARLISLE DIFFERENCE
I
Sure -Weld TPO
Reinforced Membrane
Installation
1. Sure -Weld TPO roofing systems are quick to install, as minimal labor
and few components are required. TPO systems are installed using an
Automatic Heat Welder, making sheet welding fast, clean, consistent,
and easy to learn, while reducing strain on the roofing technician.
2. APEEL Protective Film should be removed from within areas that
are to be heat -welded together. In areas that do not require heat -
welding, the APEEL Protective Film can be left in place for up to
90 days. When the installation of the entire TPO roofing system is
complete, remove and discard the APEEL Protective Film.
3. The Carlisle Mechanically Fastened Roof System installation
starts by fastening the insulation with a minimum of 4 fasteners per
4' by 8' board. The membrane is mechanically fastened to the deck
using HP -X' Fasteners and Piranha Plates" or HP-XTRA Fasteners
and Piranha XTRA Plates. Adjoining sheets of membrane are
overlapped over the fasteners and plates and joined together with a
minimum 1W -wide (4 cm) hot-air weld.
At vertical applications
At horizontal applications
Typical Properties and Characteristics
Physical Property
Tolerance on Nominal Thickness, % ASTM 0751 test method
Thickness Over Scrim, in. (mm)
ASTM 07635 optical method, average of 3 areas
Breaking Strength, Ibf (kN)
ASTM 06878 Requirement 45 -mil
60 -mil
80 -mit EXTRA
+15, -10
0.015 min
(0.380)
220 (976 N)
ASTM D751 grab min
Elongation Break of Reinforcement, %
ASTM 0751 grab method
Tearing Strength, lbf (N)
ASTM 0751 proc.13 8 in. x 8 in.
Brittleness Point, °F (°C)
ASTM D2137
Linear Dimensional Change, %
ASTM 01204, 6 hours at 158°F
15 min
55 (245) min
-40 (-40) max
±1 max
± 10
0.018 typical
(0.457)
225 (1.0) min
320 (1.4) typical
15 min
25 typical
55 (245) min
130 (578) typical
-40 (-40) max
-50 (-46) typical
± 1 max
-0.2 typical
± 10
±10
0.024 typical
(0.610)
250 (1.1) min
360 (1.6) typical
15 min
25 typical
0.034 typical
(0.864)
350 (1.6) min
425 (1.9) typical
15 min
25 typical
55 (245) min 55 (245) min
130 (578) typical 130 (578) typical
-40 (-40) max -40 (-40) max
-50 (-46) typical -50 (-46) typical
-±1 max ± 1 max
-0.2 typical -0.2 typical
Ozone Resistance, no cracks 7X ASTM D1149, 100 pphm, 168 hrs PASS
Water Absorption Resistance, mass % ± 3.0 max
ASTM 0471 top surface only 166 hours at 158°F water
Factory Seam Strength, Ibf/in (kN/m) ASTM D751 grab method
Field Seam Strength, Ibftn (kN/m)
ASTM 01876 tested in peel
PASS
PASS PASS
± 3.0 max
0.90 typical
± 3.0 max
0.90 typical
± 3.0 max
0.90 typical
66 (290) min
66 (290) min
66 (290) min 66 (290) min
No requirement
25 (4.4) min
50 (8.8) typical
25 (4.4) min
60 (10.5) typical
40 (7.0) min
70 (12.3) typical
Water Vapor Permeance, Perms
ASTM E96 proc. B
Puncture Resistance, Ibf (kN)
FTM 101 C, method 2031 (see supplemental section) ��
Properties After Heat Aging __
ASTM 0573, 32 weeks 240°F or 8 weeks @ 275°F
No cracking when bent around 3" diameter mandrel
Weight Change, %
Typical Weights Ib/ftz (kg/m2)
No requirement
0.10 max 0.10 max
0.10 max
0.05 typical 0.05 typical 0.05 typical
No requirement
PASS
No cracking
± 1.5 max
250 (1.1) min 300 (1.3) min 400 (1.8) min
325 (1.4) typical 350 (1.6) typical 450 (2.0) typical
PASS
No cracking
1.0 max
PASS
No cracking
1.0 max
PASS
No cracking
1.0 max
0.23 (1.1) 0.29 (1.4) 0.40 (2.0)
Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the
specification range for any particular property of this product.
ISure -Weld TPO
Reinforced Membrane
4. The Carlisle Fully Adhered Roofing System installation begins by
fastening the insulation at the required density necessary to meet
the appropriate warranty or wind load requirement. The substrate
and membrane are then coated with an appropriate Sure -Weld TPO
bonding adhesive and the membrane is rolled into place.
Review Carlisle specifications and details for complete installation
information.
Precautions
» Sunglasses that filter out ultraviolet light are strongly recommended, as
tan and white surfaces are highly reflective. Roofing technicians should
dress appropriately and wear sunscreen.
» Surfaces may become slippery due to frost and ice buildup. Exercise
caution during cold conditions to prevent falls.
» Care must be exercised when working close to a roof edge when
the surrounding area is snow-covered, as the roof edge may not be
clearly visible.
» Use proper stacking procedures to ensure sufficient stability of the rolls.
Exercise caution when walking on wet membrane. Membranes may be
slippery when wet.
» Store membrane in the original undisturbed plastic wrap in a cool,
shaded area and cover with Tight -colored, breathable, waterproof
tarpaulins. Membrane that has been exposed to the weather must be
prepared with Weathered Membrane Cleaner prior to hot-air welding.
» Take care not to stand or place heavy objects on the edge of folded -
over membrane, as this could cause a hard crease in the membrane.
• Maximum sustained temperature not to exceed 160°F (71°C) for TPO
membrane.
u Do not use razor blades or other sharp tools to cut the APEEL Protective
Film while it is still adhered to the TPO membrane as damage to the
underlying membrane may occur. Pull the protective film away from the
membrane prior to cutting.
» Remove APEEL Protective Film by pulling towards the center of the
roof. Do not remove the film by pulling towards the roof edge.
» A static electric charge may develop when removing APEEL Protective
Film from the surface of the membrane sheet. To avoid the possibility
of ignition, lids must be closed on any flammable products and a fire
extinguisher should be readily available.
» Color membranes will 'fade' aver time mainly due to The ultraviolet
portion of sunlight Since most roof surfaces are exposed to variable
sunlight, some areas will be more susceptible to color changes caused by
UV fading. Warranties for color membranes do not cover fading of colors.
G4RL/SLOE
SYNTEC SYSTEMS
EXTREME Testing for Severe Climates
ASTM Standard 06878 is the material specification for Thermoplastic
Polyolefin -Based Sheet Roofing. It covers material property requirements
for TPO roof sheeting and includes initial and aged properties after heat
and xenon -arc exposure. As stated in the scope of the standard, "the tests
and property limits used to characterize the sheet are values intended to
ensure minimum quality for the intended purpose." Carlisle's goal is to
produce TPO that delivers maximum performance for the intended purpose
of roofing membranes. Maximum performance requires the membrane to
far exceed the requirements of ASTM D6878.
Heat Aging accelerates the oxidation rate that roughly doubles for each
18°F (10°C) increase in roof membrane temperature. Oxidation (reaction
with oxygen) is one of the primary chemical degradation mechanisms of
roofing materials.
Carlisle Testing — Heat Aging
ASTM TEST
240°F
ASTM Requirement Sure -Weld Requirement
32 weeks**
>128 weeks
**Heat exposure comparable to 3,120 weeks (60 years) at 185°F for 8 hours/day.
» Test specimen is a 2" by 6" piece of 45 -mil membrane unbacked,
placed in circulating hot-air oven.
» Criterion — no visible cracks after bending aged test specimen around
3" -diameter mandrel.
Xenon -arc exposes the membrane samples to the combined effect of UV,
visible and infrared radiation as well as ozone, heat and water spray to
greatly accelerate the effects of outdoor weathering. The radiation dose is
measured in kilojoules per square meter (kJ/m2) at 340 nm machine UV
wavelength. The irradiance power of the xenon -arc Lamp is measured in
watts per square meter (W/m2).
Carlisle Testing — Xenon -Arc
ASTM TEST
Sure -Weld Requirements a�
ASTM 06878 45 -mil 60 -mil 80 -mil
i Requirement
Id/m2 at 340 nm I 10,080 >40,000 >50,000 >60,000
» Test specimen is a 2.75" by 5.5" piece of membrane, unbacked,
weathering side facing arc Tamp.
» Criterion — no visible cracks when viewed under 7x magnification while
wrapped around 3" -diameter mandrel.
800-479-6832 1 P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 i www.carlislesyntec.com
EXPERIENCE THE CARLISLE DIFFERENCE
Sure -Weld TPO
Reinforced Membrane
Q -Trac testing combines accelerated weathering with real-world conditions
using an array of ten mirrors to reflect and concentrate full spectrum
sunlight onto membrane test specimens. The Q -Trac device automatically
tracks the sun's path from morning to night. Also, it adjusts to compensate
for seasonal changes in the sun's altitude. Eight years in Q -Trac testing is
equal to 40 years of real-world exposure. Carlisle requires its Sure -Weld
TPO membranes to pass the equivalent of 40 years of exposure in the Q -Trac.
Carlisle Testing - Q -Trac
ASTM D6878 Requirement Sure -Weld Requirement
ASTM TEST
N/A
N/A
Equivalent of 40 years
of exposure
Environmental Cycling subjects the membrane to repeated cycles of heat
aging, hot-water immersion, and xenon -arc exposure.
u ASTM requirement - none
» Carlisle EXTREME test*:
- 10 days heat aging at 240°F (116°C) followed by
- 5 days water immersion at 158°F (70°C) followed by
- 5,040 kJ/m2 (2000 hours at 0.70 W/m2 irradiance) xenon -arc
exposure
*Test specimen is 2.75" by 5.5" piece of membrane with edges sealed.
*Criterion - after 3 complete cycles, test specimens shall remain
flexible and not have any cracking under 10x magnification while
wrapped around a 3" -diameter mandrel.
Supplemental Approvals, Statements
and Characteristics:
1. Sure -Weld TPO meets or exceeds the requirements of ASTM D6878
Standard Specification for Thermoplastic Polyolefin -Based Sheet
Roofing.
2. Radiative Properties for ENERGY STAR, Cool Roof Rating Council
(CRRC) and LEED.
3. Sure -Weld TPO membranes conform to requirements of the US
E.P.A. Toxic Leachate Test (40 CFR part 136) performed by an
independent analytical laboratory.
4. Sure -Weld TPO was tested for dynamic puncture resistance per
ASTM 05635-04 using the most recently modified impact head. 45 -mil
was watertight after an impact energy of 12.5 J (9.2 ft-lbf) and
60 -mil was watertight after 22.5 J (16.6 ft-lbf). 80 -mil EXTRA was
watertight after an impact energy of 30.0 J (22.1 ft-lbf).
5. NSF -P151 Certification for rainwater catchment system components.
- Plant 91/White Only
IMINONINIMMINE
SYNTEC SYSTEMS
Radiative Properties for
ENERGY STAR*, and LEED
Solar Reflectance Index (SRI) is calculated per ASTM E1980. The SRI is a measure of the
roof's ability to reject solar heat, as shown by a small temperature rise. It is defined so that
a standard black (reflectance 0.05. emittance 0.90) is 0 and a standard white (reflectance
0.80, emittance 0.90) is 100. Materials with the highest SRI values are the coolest choices
for roofing. Due to the way SRI is defined, particularly hot materials can even take slightly
negative values and particularly cool materials can even exceed 100.
`ENERGY STAR recommends that using the Roof Savings Calculator (rsc.ornt.gov), which
factors in both heating and cooling costs, to determine whether a cool roof will be an energy
efficient choice for your geographic climate and building type.
LEED Information
Pre -consumer Recycled Content
10%
Post -consumer Recycled Content
0%
Manufacturing Location
Senatobia, MS
Tooele, UT
Carlisle, PA
Solar Reflectance Index (SRI)
99 (white) 86 (tan)
t CRC
800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com
Carlisle, Sure -Weld, OctaGuard XT, APEEL, Piranha Plates and RP -x are trademarks of Carlisle.
ENERGY STAR Is a registered trademark awned by the U.S. Government. 'ENERGY STAR qualification is only valid in the U.S.
LEED is a registered trademark of the U.S. Green Building Councg.
01.12.18 0 2018 Carlisle.
REPRINT CODE: 600515 Sure -Weld TPO Reinforced Membrane Product Data Sheet"
Test Method
White
TPO
Tan
TPO
Gray
TPO
ENERGY STAR - Initial solar
reflectance
Solar Spectrum
Reflectometer
0.79
0.71
N/A
ENERGY STAR - Initial solar
reflectance after 3 years
Solar Spectrum
Reflectometer
(uncleaned)
0.70
0.64
N/A
CRRC - Initial solar
reflectance
ASTM C1549
0.79
0.71
0.46
CRRC - Solar reflectance
after 3 years
ASTM C1549
(uncleaned)
0.70
0.64
0.43
CRRC - Initial thermal
emittance
ASTM C1371
0.90
0.86
0.89
CRRC - Thermal emittance
after 3 years
ASTM C1371
(uncleaned)
0.86
0.87
0.88
LEED-Thermal emittance
PASS
0.90
0.86
0.85
SRI - Initial
(Solar Reflectance Index)
99
86
53
SRI - 3 year aged
(Solar Reflectance Index)
85
77
48
Solar Reflectance Index (SRI) is calculated per ASTM E1980. The SRI is a measure of the
roof's ability to reject solar heat, as shown by a small temperature rise. It is defined so that
a standard black (reflectance 0.05. emittance 0.90) is 0 and a standard white (reflectance
0.80, emittance 0.90) is 100. Materials with the highest SRI values are the coolest choices
for roofing. Due to the way SRI is defined, particularly hot materials can even take slightly
negative values and particularly cool materials can even exceed 100.
`ENERGY STAR recommends that using the Roof Savings Calculator (rsc.ornt.gov), which
factors in both heating and cooling costs, to determine whether a cool roof will be an energy
efficient choice for your geographic climate and building type.
LEED Information
Pre -consumer Recycled Content
10%
Post -consumer Recycled Content
0%
Manufacturing Location
Senatobia, MS
Tooele, UT
Carlisle, PA
Solar Reflectance Index (SRI)
99 (white) 86 (tan)
t CRC
800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com
Carlisle, Sure -Weld, OctaGuard XT, APEEL, Piranha Plates and RP -x are trademarks of Carlisle.
ENERGY STAR Is a registered trademark awned by the U.S. Government. 'ENERGY STAR qualification is only valid in the U.S.
LEED is a registered trademark of the U.S. Green Building Councg.
01.12.18 0 2018 Carlisle.
REPRINT CODE: 600515 Sure -Weld TPO Reinforced Membrane Product Data Sheet"
Product Data
FASTENERS lit PLATES
Carlisle SynTec Systems offers an array of fasteners and plates to
complement our roofing systems. From pre -assembled choices for
EPDM installations to Purlin fasteners for Metal Retrofit Systems and
Piranha plates for Sure -Weld® options, our mission continues to be to
provide all components necessary for the application of a long-lasting
and secure single -ply roofing system from Carlisle.
EPDM
Sf
Sure -Seale & Sure -White® EPDM
Sure -Weld TPO
Sure -Flex'" PVC
HP FASTENER
CD -10
Applicable to steel, 22 -gauge and heavier, CDX
plywood and wood plank deck types. Can be used
to secure Sure -Tough membranes, RUSS and
insulation. Longer fastener sizes available
as special order.
Sizes Available:
1Y.", 2"-15" (1" Increments)
Size & Quantity Per Box:
2"— 6":1,000; 7"-12": 500;13"-15": 250
1'Y4":1000
�EPDh�
SWi
Pa
Applicable for concrete decks. Used to secure
Sure -Seal, Sure -Weld and Sure -Flex membranes
and for insulation securement.
Sizes Available:
2"— 6" (1" Increments)
7"-12" (1" Increments)
Size & Quantity Per Box:
2"— 8": 500; 9"-12": 250
HP -X FASTENER*' & HP-XTRA FASTENER
Sf�
Size & Quantity Per Box:
500 (2" — 6"), 250 (7" — 8")
A 415 diameter fastener applicable to steel,
wood and CDX plywood. Can be used to secure
Sure -Seal, Sure -Weld and Sure -Flex membranes.
Sizes Available:
2"-8" (1" Increments)
10"-16" (2" Increments)
Size & Quantity Per Box:
2"— 4": 1,000; 5"-12": 500;14"-16": 250
HP-XTRA FASTENER
Also Available (Not shown)
A 421 diameter fastener applicable to steel, wood
and CDX plywood decks.
Sizes Available:
2" —8" (1" increments)
Expedence the Carlisle Difference
lirin-o?
INSULFAST"M
SURE -TITS®
A 412 diameter fastener applicable to wood
decks and steel, 22 -gauge and heavier, decks.
Used only for insulation attachment.
Sizes Available:
2"— 8" (1" Increments)
1%",, 2Y." 3"— 8" (1" Increments)
Size & Quantity Per Box:
2"— 8":1,000
HD 14-10
A 0.33" diameter fastener applicable to steel,
22 -gauge and heavier. Can be used for Sure -
Tough membrane securement in mechanically
attached systems.
Sizes Available:
2"-8" (1" Increments)
Size & Quantity Per Box:
2", 3": 500; 4"— 8": 250
fPDM
SSW
001
St j
A 414 diameter fastener used for Sure -Tough,
Sure -Weld and Sure -Flex membrane securement
into wood and concrete decks. Also applicable
to insulation securement into steel, wood and
concrete decks.
Sizes Available:
2"-12" (1" Increments)
14"— 24" (2" Increments)
Size & Quantity Per Box:
2"— 4":1,000; 5" 11": 500; 12"— 24": 250
GYPTEC FASTENER & PLATE
EPI#
SW
goo'
rsr
800-479-6832 • P.O. Box 7000 • Carlisle, PA 17013 • Fax: 717-245-7053 • www.carlislesyntec.com
Applicable to cementitious wood fiber,
lightweight concrete and gypsum decks. Can
be used to secure Sure -Tough, Sure -Weld and
Sure -Flex membranes and insulation.
Sizes Available:
2'h"-10" ('h" increments)
Size & Quantity Per Box:
2h"— 7": 500; 7%z"-10": 250
GYPTEC PLATE
Sizes Available:
2" Metal membrane plate
3" Metal insulation plate
Quantity Per Box: 1,000
svNTHC srsrsnr„
Product Data
FASTENERS & PLATES
ASAP WITH POLYMER PLATE
A pre -assembled #112 diameter fastener and
plastic insulation plate applicable to steel and
wood decks. Used to secure insulation only.
Longer fastener sizes available as special order.
Sizes Available:
3"— 12" (1" Increments)
Size & Quantity Per Box:
2'A"— 8": 250; 9"-12": 200
HP PRE -ASSEMBLED
Pre -assembled HP Fastener and Polymer seam
plate applicable to steel, wood and CDX plywood
decks. Used to secure Sure -Tough membranes.
Sizes Available:
21/4", 3"-12" (1" Increments)
Size & Quantity Per Box:
21/4", 3", 31/4', 33/a": 450; 4", 5": 400; 6": 350;
7", 8": 300; 9": 250; 10"— 12": 200
HP POLYMER SEAM PLATE
Along with the HP Fastener, used to mechanically
fasten reinforced Sure -Tough membrane and
RUSS over steel decks.
Sizes Available:
2" diameter
Quantity Per Box: 1,000
HP-XTRA POLYMER SEAM PLATE
Also Available (Not shown)
For use with HP-XfRA Fastener to secure Sure -Tough
membranes to steel decks.
Sizes Available:
23/8" diameter
Quantity Per Box: 1,000
SEAM FASTENING PLATE
Applicable with HP, HD 14-10 and CD -10 fasteners
to mechanically attach reinforced Sure -Tough
membrane (excluding steel decks) and RUSS
(except when used with mechanically fastened
EPDM to steel decks).
Sizes Available:
2" diameter
Quantity Per Box: 1,000
Experience the Carlisle Difference
HP -X ASAP
A pre -assembled HP -X Fastener and Piranha
PlateTM applicable to steel, wood and CDX
plywood decks. Used to secure Sure -Weld and
Sure -Hex membranes.
Sizes Available:
2"-10" (1" Increments)
12"-16" (2" Increments)
Size & Quantity Per Box:
2"— 9": 250;10"-12": 200;14"-16":150
RHINOBOND® PLATE
PIRANHA PLATE
3" -round, specially coated plates used with HP -X
Fasteners and the RhinoBond induction welding
system. Available in TPO and PVC versions.
Sizes Available:
3" diameter
Quantity Per Box: 500/carton
SW
Sf
Along with the appropriate fastener, used to
secure Sure -Weld and Sure -Flex membranes
to steel, concrete and wood decks.
Sizes Available:
23/a" diameter
Quantity Per Box: 1,000
HP-XTRA PIRANHA PLATE
Also Available (Not shown)
For use with HP-XTRA Fastener to secure Sure -Weld
and Sure -Flex membranes to steel and wood decks.
Sizes Available:
23/e" diameter
Quantity Per Box: 1,000
INSULATION FASTENING PLATE
800-479-6832 • P.O. Box 7000 • Carlisle, PA 17013 • Fax: 717-245-7053 • www.carlislesyntec.com
Carlisle, Sura -Seal, Sure -Weld, ReeceBACK Sure -Rex, Sure -White, HP -X Fastener, lnsulFAST, Sure -Tito and RUSS are trademarks of Carlisle.
f#rinoeond is a registered trademark of CMG, Inc.
REPRMr REQUEST CODE: 600269 - Fasteners & Plates Product Data Sheet - 02.19.13 ® 2013 Carlisle.
Applicable with InsulFast, HP, CD -10 and HD
14-10 fasteners. Used for Insulation securement
only on steel, wood and concrete decks.
Sizes Available:
3" diameter
Quantity Per Box: 1,000
SYNTEC SYSTEMS
EXPERIENCE THE CARLISLE DIFFERENCE
ISure -Weld' TPO
Non -Reinforced Flashing
Overview
Carlisle's Sure -Weld TPO Non -Reinforced Flashing is a 60 -mil
thermoplastic polyolefin (TP0)-based membrane available in 12" and 24"
by 50' rolls. When the use of prefabricated accessories is not feasible, this
product can be used to create inside and outside corners, field -fabricated
pipe flashings, sealant pockets, and scuppers. Standard colors are white,
tan, and gray.
Features and Benefits
• New and improved TPO Flashing provides 35% more flexibility, making
it easier to field -fabricate details
» Compounded with the same OctaGuard XT'" weathering package as
Carlisle's Sure -Weld TPO membranes for maximum longevity
» Superior weldability allows for consistent, high-quality seams in
penetrations and other critical roof areas
» Available in white, gray, and tan colors to match Carlisle's Sure -Weld
TPO membranes
Installation
1. TPO Flashing is used to flash various roofing system details and
penetrations. The specific installation method will vary based on the
situation.
2. Use a lower temperature setting on the heat welder than when
welding reinforced TPO membrane. Typically, a setting of "6" on a
scale of "10" is appropriate for welding TPO Flashing.
HtmsS
t :4RLISLi
SYNTEC SYSTEMS
3. Use the edge of the roller to crease the flashing into any membrane
step -offs for a proper seal.
Review Carlisle specifications and details for complete installation
information.
Precautions
» Review the applicable Safety Data Sheet for complete safety
information prior to use.
Sunglasses that filter out ultraviolet Tight are strongly recommended, as
tan and white surfaces are highly reflective. Roofing technicians should
dress appropriately and wear sunscreen.
» Store TPO Flashing in a cool, shaded area and cover with light-colored,
breathable, waterproof tarpaulins. TPO Flashing that has been exposed
to the weather for approximately 7 days or longer must be prepared
with Weathered Membrane Cleaner prior to hot air welding.
Typical Properties and Characteristics
Properties
ASTM Test
Method
Specification
Tolerance on nominal thickness, %
D 412
plus 15/ minus 10
Weight, lb/ft2 (kg/m2), typical
0.30 (1.5)
Tensile strength, min., psi (Mpa)
0 412 Die C
1200 (8.3)
Elongation, ultimate, min., %
D 412 Die C
600
Tear strength, min., Ibf/in (kN/m)
D 624 Die C
250 (43.8)
Ozone resistance, 168h @ 100 pphm,
50% ext.
D 1149
No Cracks
Heat aging: 28 days at 240°F (116°C)
Tensile strength, min., psi (MPa)
Elongation, ultimate, min., %
Tear strength, min., Ibf/in (kN/m)
Linear dimensional change, max. %
D 573
D 412
D 412
D 624
D 1204
1000 (6.9)
500
200 (35.0)
±4
Resistance to Xenon -arc weathering
Xenon -Arc, 10,080 kJ/m2 total radiant
Exposure, visual condition at 10X
G 155
0.70 W/m2
80°C B.P.T.
No Cracks
Typical properties and characteristics are based on samples tested and are not guaranteed
for all samples o1 this product. This data and information is intended as a guide and does not
reflect the specification range for any particular property of this product.
LEED Information
Pre -consumer Recycled Content
0%
Post -consumer Recycled Content
0%
Manufacturing Location
Greenville, IL
Solar Reflectance Index (SRI)
N/A
800-479-6832 1 P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com
Carlisle and OctaGuard XT are trademarks of Carlisle. Suro-Weld is a registered trademark of Carlisle.
LEER is a registered trademark of the. U.S. Green Building Council.
10.06.15 C! 2015 Carlisle.
REPRINT CODE 605089 - "Sure -Weld "IPO Non -Reinforced Flashing Product Data Sheat"
EXPERIENCE THE CARLISLE DIFFERENCE
I
Sure-WeId° TPO
Bonding Adhesive
Overview
Carlisle's Sure -Weld TPO Bonding Adhesive is a high-strength solvent -
based contact adhesive that allows bonding of TPO membrane to various
porous and non -porous substrates.
Features and Benefits
Solvent -based bonding adhesive that allows for quick drying
A Can be roller -applied with medium nap roller
A Provides excellent adhesion to various substrates
Coverage Rate
60 ft2 (5.6 m2) per gallon finished surface. Coverage rates are average and
may vary due to conditions on the jobsite. Porous surfaces and substrates
may require more bonding adhesive than the typical coverage rate.
Mixing
Stir thoroughly until ail settled pigments are dispersed and the adhesive
is uniform in color. Minimum 5 minutes stirring is recommended.
Application
1. The surface, on or against which adhesive is to be applied, shall
be clean, smooth, dry, free of fins, sharp edges, loose and foreign
materials, oil and grease. Depressions greater than 1/4" (6 mm)
should be feathered, using epoxy, mortar or other approved patching
material. AM sharp projections shall be removed by sweeping,
blowing or vacuum cleaning.
liton
2. After thorough stirring (minimum 5 minutes), apply TPO Bonding
Adhesive to substrate and membrane using a 9" (23 mm) medium
nap roller. Application shall be continuous and uniform, avoiding
globs or puddles. An open time of 5 to 50 minutes, based on drying
conditions is recommended before assembly. TPO Bonding Adhesive
must be allowed to dry until it does not string or stick to a dry finger
touch. Any coated area which has been exposed to rain should be
allowed to dry and then recoated. Do not apply adhesive to splice
areas to be hot-air welded.
3. Roil the membrane onto the adhesive -coated substrate while
avoiding wrinkles. Immediately brush down the bonded portion
of the sheet with a soft -bristle push broom or a clean dry roller
applicator to achieve maximum contact.
Review current Carlisle specifications and details for specific application
requirements.
Precautions
» Review the applicable Material Safety Data Sheet for complete safety
information prior to use.
A TPO Bonding Adhesive is EXTREMELY FLAMMABLE — it contains
solvents that are dangerous fire and explosion hazards when exposed
to heat, flame or sparks. Do not smoke while applying. Do not use in
a confined or unventilated area. Vapors are heavier than air and may
travel along ground or may be moved by ventilation and ignited by pilot
lights, other flames, sparks, heaters, smoking, electrical motors, static
discharge or other ignition sources at locations distant from material
handling point and flashback. All containers should be grounded
when material is transferred from one container to another. A red
caution label is required when shipping. A fire extinguisher should
be available. In case of fire, use water spray, foam, dry chemical or
carbon dioxide. Do not use a solid stream of water because it can
scatter and spread the fire.
3 Avoid breathing vapors. Keep container closed when not in use.
Use with adequate ventilation. If inhaled, remove to fresh air. If not
breathing, perform artificial respiration. If breathing is difficult, give
oxygen. Call a physician immediately. During application, efforts must
be made to prevent fumes from entering the building via air ventilation
ducts. Do not place open containers or mix adhesive near fresh air
intake units. When possible, shut down or seal off the closest units.
b If swallowed, DO NOT INDUCE VOMITING. Call a physician immediately.
n Avoid contact with eyes. Safety glasses or goggles are recommended.
If splashed in eyes, immediately flush eyes with plenty of clean water
for at least 15 minutes. Contact a physician immediately.
800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com
EXPERIENCE THE CARLISLE DIFFERENCE
ISure -Weld TPO
Bonding Adhesive
» Avoid contact with skin. Wash hands thoroughly after handling. In case
of contact with skin, thoroughly wash affected area with soap and
water. Contact physician if irritation persists.
Note: Permeation -resistant gloves (that meet ANSI/ISEA 105-2005)
are recommended to be wom when using this product to protect hands
from irritating ingredients.
Do not thin TPO Bonding Adhesive. Thinning will affect performance.
Excessively thick or gelled material should be discarded.
» Jobsite storage in excess of 90°F (32°C) may affect product shelf life.
Should the TPO Bonding Adhesive be stored at temperatures lower than
60°F {15°C), restore to room temperature prior to use.
Opened containers of TPO Bonding Adhesive should be used within
48 hours. Adhesives will begin to thicken after this point, making it
difficult, and eventually impossible, to control applied thickness. In hot
weather, do not leave sealed containers on roof for prolonged periods
of time. In cold weather, keep material at room temperature until ready
to use. Stir adhesive occasionally while using.
Adhesive must be allowed to dry thoroughly. If membrane is mated
with the substrate prior to the adhesive being dry, blistering will occur
and not subside over time.
» KEEP OUT OF THE REACH OF CHILDREN.
11111111111111111111111111111111111
CARLISLE
SYNTEC SYSTEMS
Typical Properties and Characteristics
Base
Synthetic rubber
Color
Yellow
Solids
20%
Flash Point
-4°F (-20°C) closed cup
Brookfield Viscosity
2600 centipoises
Average Net Weight
7.1 lbs/gal (3.2 kg)
Packaging
5 -gal pail
Shelf Life
1 year
Typical properties and characteristics are based on samples tested and are not guaranteed
for all samples of this product. This data and information is intended as a guide and does not
reflect the specification range for any particular property of this product.
LEED Information
Pre -consumer Recycled Content 0%
Post -consumer Recycled Content 0%
Manufacturing Location
Carlisle, PA
VOC Content
670 g/L
800-479-6832 1 P.O. Box 7000 I Carlisle, PA 17013 1 Fax: 717-245-7053 I www.carlislesyntec.com
Carlisle and Sure -Weld are trademarks at Carlisle.
LEED is a registered trademark of the U.S. Green Building Council,
01.13.14 ® 2014 Carlisle.
REPRINT 000E:605925 -'Sure-Weld Bending Adhesive Product Data Sheet'
EXPERIENCE THE CARLISLE DIFFERENCE
(Sure -Weld TPO
Cut -Edge Sealant
Overview
Carlisle's TPO Cut -Edge Sealant is a medium solids content, free-flowing,
polymeric material designed to be used for sealing cut edges of Sure -Weld
TPO Reinforced Membrane. It is available in clear for use with various
colors of TPO membrane.
Garlisle TPO Cut -Edge Sealant is used to seal cut edges of TPO Membrane,
providing a waterproof barrier where scrim reinforcement is exposed.
Features and Benefits
» Provides excellent sealing of exposed fabric at cut
membrane edges
» Squeeze -bottle packaging allows easy, no -mess application
» Available in clear for use with various colors of Sure -Weld
TPO membrane
kti
ggig4
SYNTEC SYSTEMS
Coverage Rate
Approximately 225' — 275' (70 — 85 m) per 16 -oz. bottle when applied with
'/s" (3 mm) bead. Approximately 115' —140' (35 — 45 mm) per 8 -oz. bottle
when applied with 1/s" (3 mm) bead.
»
Application
1. All surfaces to be sealed with TPO Cut -Edge Sealant must be clean,
dry and free from oil, grease, dirt and other foreign materials.
2. Apply a'/a" (3 mm) bead of TPO Cut -Edge Sealant from the plastic
squeeze bottle to seal cut edges of reinforced TPO membrane. Do
not apply TPO Cut -Edge Sealant on vertical surfaces.
3. Sealant should be tack -free in 2 hours and fully cured in 24 hours
depending on weather conditions and application thickness.
Review Carlisle specifications and details for complete installation
information.
Precautions
800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com
EXPERIENCE THE CARLISLE DIFFERENCE
ISure -Weld TPO
Cut -Edge Sealant
Review the applicable Material Safety Data Sheet for complete safety
information.
TPO Cut -Edge Sealant is FLAMMABLE — it contains solvents that are
dangerous fire and explosion hazards when exposed to heat, flame or
spark. Do not smoke while applying. Do not use in a confined area or
unventilated area. Vapors are heavier than air and may travel along the
ground to a distant ignition source and flashback.
» Avoid breathing vapors. Keep container closed when not in use.
Use with adequate ventilation. If inhaled, remove to fresh air. If not
breathing, perform artificial respiration. If breathing is difficult, give
oxygen. Call a physician immediately.
» If swallowed, DO NOT INDUCE VOMITING. Cali a physician immediately.
» Avoid contact with eyes. Safety glasses or goggles are recommended.
If splashed in eyes, immediately flush eyes with plenty of water for at
least 15 minutes. Contact a physician immediately.
Avoid contact with skin. Permeation -resistant gloves (that meet ANSI/
ISEA 105-2005) recommended. Wash thoroughly after handling. In
case of contact with skin, thoroughly wash affected area with soap
and water.
»
Jobsite storage temperatures in excess of 90°F (32°C) may affect
product shelf life. Should the TPO Cut -Edge Sealant be stored at
temperatures below 60°F (15°C), restore to room temperature prior
to use.
» KEEP OUT OF THE REACH OF CHILDREN
02.14.14 ® 2014 Garllste,
REPRINT CODE: 604821- Sure -Weld Cut -Edge Product Data Sheet'
CARLISLE
SYNTEC SYSTEMS
Typical Properties and Characteristics
Base
Synthetic Rubber
Color
Clear
Solids
14%
Viscosity
3,500 cps
Flash Point
39°F (4°C)
Net Weight Gallon
7.4 Ibs (3.3 kg)
Resistance to:
Ozone
Excellent
UV
Excellent
Water
Excellent
Packaging
Eight 16 -oz. bottles/carton (3.8 L)
or two 8 -oz. bottles (1.9 L)
Shelf Life
1 year
Typical properties and cha acteristics are based on samples tested and are not guaranteed
for all samples of this product. This data and information is intended as a guide and does not
reflect the specification range for any particular property of this product.
LEED Information
Pre -consumer Recycled Content
0%
Post -consumer Recycled Content
Manufacturing Location
Rockland, MA
VOC Content
750 g/L
800-479-6832 1 P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 1 www.carfistesyntec.com
Carlisle and Sure -Weld are trademarks of Carlisle.
LEED is a registered trademark of the U.S. Breen Building Council.
EXPERIENCE THE CARLISLE DIFFERENCE
I
Sure-WeId TPO
Coated Metal
Overview
Sure -Weld TPO Coated Metal is a 24 -gauge (0.6 mm) galvanized steel
sheet that is coated with a layer of .035" non -reinforced TPO flashing. TPO
membrane may be welded directly to the coated metal, eliminating the
need to strip in the metal with a separate piece of TPO Pressure -Sensitive
Coverstrip. The sheet is cut to the appropriate width and used to fabricate
metal drip edges or other roof perimeter edging profiles. The metal is
available in 4' by 10' (1.2 m by 3.1 m) sheets and comes packaged 10 or 25
sheets per pallet.
Carlisle's TPO Coated Metal is part of Carlisle's comprehensive TPO
accessory offering that meets the stringent quality tolerances required to
be included in a Carlisle warranted roofing system.
Features and Benefits
Allows direct welding of TPO membrane to the metal, eliminating
the need to strip in edging with additional TPO Pressure -Sensitive
Coverstrip.
» Easy to cut and form for creating a variety of edge sizes and profiles.
Ran -4*
SYNTEC SYSTEMS
Installation
1. Install TPO Coated Metal with 1/13" to /4" (3-6 mm)
between adjoining sections.
2. Install 2" -wide (5 cm) duct tape over joints in TPO Coated Metal.
3. Heat -weld 6" -wide (15.5 cm) piece of TPO non -reinforced flashing
over joint.
4. Position TPO reinforced membrane and heat -weld to the TPO Coated
Metal with a minimum 11/2" (4 cm) weld.
Review Carlisle specifications and details for complete installation
information.
Precautions
Store coated metal in a cool, shaded area and cover with light-colored,
breathable, waterproof tarpaulins. TPO Coated Metal that has been
exposed to the weather must be prepared with Weathered Membrane
Cleaner prior to hot-air welding.
Typical Properties and Characteristics
Sheet Size
4' by 10' (1.2 m by 3.0 m)
Weight
1.1 Ib/ft2 (5.4 kg/m1)
Color
Gray, Tan and White
Flashing Thickness
0.035" (0.9 mm) nominal
Steel Thickness
0.024" (0.6 mm) nominal (24 gauge)
Steel Type
Hot Dipped Galvanized Steel -- G90
Conforms to ASTM A653
Packaging
10 or 25 sheets per pallet
Typical properties and characteristics are based on samples tested and are not guaranteed
for all samples of this product. This data and information is intended as a guide and does not
reflect the specification range for any particular property of this product.
LEED Information
Pre -consumer Recycled Content
09'0
Post -consumer Recycled Content
0%
Manufacturing Location
Franklin Park, IL
Solar Reflectance Index (SRI)
N/A
800-479-6832 I P.O. Box 7000 1 Carlisle. PA 17013 I Fax: 717-245-7053 I www.cartislesyntec.com
Carlisle and Sure -Weld aro trademarks of Carlisle.
LEED is a registered trademark of the U.S. Green Building Council.
02.26.16 C 2016 Carlisle..
REPRINT CODE: 604820 - "Sure -Weld TPO Coated Metal Product Data Sheet"
EXPERIENCE THE CARLISLE DIFFERENCE
Sure-WeId TPO
Pipe Seals
Overview
Let Carlisle simplify your next Sure -Weld TPO installation with TPO Molded
Pipe Seals. TPO Pipe Seals are injection -molded, pre -formed flashings
for pipes 3/4" (19.0 mm) to 8" (203.2 mm) in diameter. TPO Pipe Seals
are packaged in boxes of eight and come with universal stainless steel
clamping rings.
Carlisle's TPO Molded Pipe Seals are part of the Certified Fabricated
Accessory (CFA) program. Certified Fabricated Accessories are the
only factory -fabricated TPO accessories that meet the stringent quality
tolerances required to be included in a Carlisle warranted roofing system,
Features and Benefits
»
Provides a reliable method of waterproofing round pipe penetrations
Provides a substantial labor savings compared to field fabricating from
non -reinforced flashing
» Provides more consistent appearance than field -fabricated pipe flashings
» Double -ribbed cutting guide provides easier, smoother and straighter cuts
» Rib design also keeps the clamp in the proper position for the life of the
roofing system
Productivity Boosting Features and Benefits:
» Up to 60% labor savings compared to traditional
field fabrication
Quick and simple installation with no
stretching required
» Provides a consistent, finished appearance
CARLISLE
SYNTEG SYSTEMS
Certified
Fabricated
Accessory
Installation
1. Cut pipe seal between the two raised "ribs" to the desired diameter
as illustrated on the flange of the pipe seal. (Do not cut off both
raised "ribs".)
2. Pull TPO Pipe Seal over pipe until base flange is in contact with the
membrane. (Application of heat to the top portion of the TPO Pipe
Seal may be necessary to allow installation over the pipe.)
3. Mark pipe around the top of the TPO Pipe Seal.
4. Pull TPO Pipe Seal upwards on pipe until mark on the pipe is visible.
5. Install Water Cut-off Mastic below mark which indicates the top of
the installed TPO Pipe Seal.
6. Pull TPO Pipe Seal back down over pipe and into position.
7. Heat weld the TPO Pipe Seal base flange to deck membrane (the
hand -welder temperature setting should be between 5 and 6).
8. Install a stainless steel universal clamping ring to provide constant
compression of the sealant.
Review Carlisle specifications and details for complete installation
information.
Precautions
» Remove all lead and other flashing.
» Temperature of pipe must not exceed 160°F (71 °C).
» When used with mechanically fastened membrane, install a minimum
of four fastening plates around pipe penetrations. Position fastening
plates around the penetration so the plates are covered by the pipe
seal flange. A minimum 1W -wide weld must be maintained around the
outer edge of the flange beyond the plates. If fastening plates cannot
be installed in a manner to allow a minimum 11/2" weld, the plates
must be placed outside the TPO Pipe Seal flange and covered with a
reinforced TPO overlay.
• Store pre -molded pipe seals in a cool, shaded area and cover with light-
colored, breathable, waterproof tarpaulins. TPO Pipe Seals or membrane
that has been exposed to the weather prior to use must be prepared
with Weathered Membrane Cleaner prior to hot-air welding.
800-479-6832 1 P.O. Box 7000 I Garlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com
EXPERIENCE THE CARLISLE DIFFERENCE
ISure -Weld TPO
Pipe Seals
Typical Properties and Characteristics
Sizes
Packaging
3/" to 8" 0.0. pipe (19.0 to 203.2 mm)
8/box
Weight (each) 0.63 lbs (0.3 kg)
Material ; Injection -molded TPO
Color f White, gray and tan
Typical properties and characteristics are based on samples tested and are not guaranteed
for all samples of this product. This data and information is intended as a guide and does not
reflect the specification range for any particular property of this product.
CARLISLE
SYNTEC 01'6 TE
LEED Information
Pre -consumer Recycled Content i 0%
Post -consumer Recycled Content ! 0%
Manufacturing Location I Bloomingdale, IL
Solar Reflectance Index (SRI)
N/A
Please use the chart below to cross-reference your pipe size with the proper step to cut as shown.
Copper Tubing (C.T.S.)
Nominal tube size i 3b" 1" vie
Pipe 0.0. - T ' .881.13 1.38
Step of boot used 1 T~_ 1 1
Ph"
1.63
11
2"
2'h"
3"
4"
5"
6"
8"
2.13 2.63 3.13 4.13
2
2
3
4
5.13 6.13 N/A
6 N/A
5
Schedule 40 / 80 Steel Pipe - PVC Standard - Polyethylene Pipe IPS
Nominal tube size 3/40
Pipe O.D. _ 1.05
Step of boot used 1
1" 1t/a"
1.32 1.66
1 1'/
1'h"
1.90
1'h
2"
2.38
2
2t/z" 3" 4"
5"
6"
8"
2,88 3.50 4.50 5.56 6.63 8.63
3 3
4 5 6
8
Cast Iron Pipe
Nominal tube size
Pipe 0.0.
Pit Class A & Spun 100-250
2" 3" 4" 6"
8"
2.50
3.96
Step of boot used
1 2
4
4.80 6.90
5 6
9.50
N/A
2"
N/A
N/A
3"
Pit Class 8, C & D
4" 6"
5.00 7.10
4 5 6
3.96
8"
9.30
N/A
Sewer - Soil Pipe
PVC Plastic SDR 35 & 41 - Cast Iron Soil Pipe no hub - service weight & extra heavy
Nominal tube size 4" 4" 4" 4" 6"
_Pipe 0:0. 4.22 4.38 4.30 4.62 6.28
Step of boot used 4 4 4 4 6
6" 6" 6" 8" 8"
6.30 6.30 6.62 8.40 8.38 8.38
6 6 6 8 8 8
8" 8"
8.75
8
Conduit EMT
Nominal tube size y4" 1" 1'/4" 1'k" 2" 21/2" 3" 31/2"
Pipe 0.D. .922 1.16 1.51 1.74 2.19 2.88 3.50_ R
4.00
Step of boot used 1 1 1 11/2 2 �3 � �3 4
4"
4.50
4
Conduit IMC
Nominal a/4
tube size " 1" 11/4" 1'/z" 2" 214" 3" 3' "
_
Pipe 0.0. _ 1.02 1.29 1.63 1.88 2.36 2.85 3.47 3.97
Step of boot used 1 1 11/2 11/2 2 3 3 4
4"
4.46
4
Conduit Rigid
Nominal tube size '/i" 1" 11/4" 11/2" 2" 23/2" 3" 31/2" 4"
5"
Pipe 0.0. 1 1.05 1.32 1.66 1.90 2.37 2.87 3.5 4 4.5
Step of boot used 1 1 1 11/2 11/2 2 A 3 3 4 4
12,120.17 2014 Carlisle.
REPRINT CODE: 604453 - "Sure -Weld TPD Pipe Seals Product Data Sheet"
5.56
5
800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com
Carlisle and Sure -Weld are trademarks of Carlisle.
t.EED is a registered trademark of the U.S. Green Building Council.
EXPERIENCE THE CARLISLE DIFFERENCE
I
Sure-WeId TPO
Inside Corners
Overview
Let Carlisle simplify your next Sure -Weld TPO installation with
prefabricated Inside Corners. TPO Inside Corners are pre -molded and are
used for flashing inside corners on a variety of details. Installation is fast
and easy with no cutting or stretching required.
Carlisle's TPO Inside Corners are part of the Certified Fabricated Accessory
(CFA) program. Certified Fabricated Accessories are the only factory -
fabricated TPO accessories that meet the stringent quality tolerances
required to be included in a Carlisle warranted roofing system.
Features and Benefits
A Forms easily into "out -of -square" comers that are not exactly 90°
A Provides substantial labor savings compared to field fabricating the
flashing detail from non -reinforced flashing
A More consistent appearance than inside corners field -fabricated
from flashing
03.03.14 O 2014 Carlisle.
REPAINT CODE: 602105 -'Inside Comers Product Data Sheet"
SYNTEC SYSTEMS
Certified
Fabricated
Accessory
Installation
1. Position the TPO Inside Corner into the building corner, begin
welding at the innermost corner point and work away from the
corner.
2. Use a lower temperature setting on the heat welder than when
welding reinforced TPO membrane. (Typically a setting of 6 on a
scale of 10 is appropriate for welding TPO Inside Corners).
3. Use the edge of the roller to crease the corner flashing into any
membrane step-off to create a proper seal.
4. Probe all welded edges of the corner only once the material has
completely cooled to ensure watertight performance.
Review Carlisle specifications and details for complete installation
information.
Precautions
A Store TPO Inside Corners in a cool, shaded area and cover with light-
colored, breathable, waterproof tarpaulins. TPO Inside Corners or TPO
membrane that has been exposed to the weather prior to use must be
prepared with Weathered Membrane Cleaner before hot air welding.
Typical Properties and Characteristics
Thickness
0.060" (1.5 mm)
Packaging
12/bag
Color
White, Gray, Tan
Material Injection molded
Typical properties and characteristics are based on samples tested and are not guaranteed
for all samples of this product. This data and information is intended as a guide and does not
reflect the specification range for any particular property of this product.
LEED Information
Pre -consumer Recycled Content
0%
Post -consumer Recycled Content
0%
Manufacturing Location
Bloomingdale, IL
Solar Reflectance Index (SRI)
N/A
800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com
Carlisle and Sure -Weld are trademarks of Carlisle.
LEED is a registered trademark of the U.S. Green Building Council..
EXPERIENCE THE CARLISLE DIFFERENCE
I
Sure-WeId TPO
Outside Corners
Overview
Let Carlisle simplify your next Sure -Weld TPO installation with
prefabricated Outside Corners. Sure -Weld TPO Outside Corners are pre -
molded and are used for flashing outside comers on a variety of details.
Installation is fast and easy with no cutting or stretching required.
Carlisle's Sure -Weld TPO Outside Corners are part of the Certified
Fabricated Accessory (CFA) program. Certified Fabricated Accessories are
the only factory -fabricated TPO accessories that meet the stringent quality
tolerances required to be included in a Carlisle warranted roofing system.
Features and Benefits
» Provide a substantial labor savings compared to field fabricating from
non -reinforced flashing
» Pre -stretched, multi -wave design allows wrapping outside comers that
are out of square and not exactly 90 degrees
» More consistent appearance than outside corners field fabricated
from flashing
Installation
1. Place the center point of the Sure -Weld TPO Outside Corner over the
outside intersection of the corner.
2, Begin welding at the innermost center point and work away from the
center by first welding the vertical portion of the flashing.
3. Use a lower temperature setting on the heat welder than when
welding reinforced TPO membrane. (Typically a setting of 6
on a scale of 10 is appropriate for welding TPO Outside Corners).
SYNTEC SYSTEMS
Certified
Fabricated
Accessory
4. Use the edge of the roller to crease the corner flashing into any
membrane step-off to create a proper seal.
5. Probe all welded edges of the corner only once the material has
completely cooled to ensure watertight performance.
Review Carlisle specifications and details for complete installation
information.
Precautions
Store TPO Outside Corners in a cool, shaded area and cover with light-
colored, breathable, waterproof tarpaulins. TPO Outside Corners or TPO
membrane that has been exposed to the weather prior to use must be
prepared with Weathered Membrane Cleaner before hot-air welding.
Typical Properties and Characteristics
Thickness
0.060" (1.5 mm)
Packaging
12 per bag
Color
White, Gray, Tan
Material Injection -molded TPO
Typical properties and characteristics are based on samples tested and are not guaranteed
for all samples of this product. This data and information is intended as a guide and does not
reflect the specification range for any particular property of this product.
LEED Information
Pre -consumer Recycled Content 0%
Post -consumer Recycled Content 0%
Manufacturing Location Bloomingdale, IL
Solar Reflectance Index (SRI) N/A
800-479-6832 1 P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec,com
Carlisle and Sure -Weld are trademarks 51 Carlisle.
LEEO is a registered trademark of the U.S. Green Building Council.
0920.13 Cr 2013 Carlisle.
REPRINT CODE: 604459 - "Sure -Weld TPO Outside Comers Product Data Sheet'
EXPERIENCE THE CARLISLE DIFFERENCE
I
Sure -Weld' TPO
IT -Joint Covers
Overview
Let Carlisle simplify your next Sure -Weld TPO installation with molded
T -Joint Covers. Sure -Weld TPO T -Joint Covers are used to seal step -offs
at splice intersections. installation is mandatory on all 60- and 80 -mil TPO
systems and on 45 -mil systems where step -offs have not been properly
sealed. Sure -Weld TPO T -Joint Covers consist of 60 -mil non -reinforced
TPO formed into a perfect 4.5" -diameter circle and packaged 100 parts per
carton. Available in white, tan and gray.
Carlisle's Sure -Weld TPO T -Joint Covers are part of the Certified Fabricated
Accessory (CFA) program. Certified Fabricated Accessories are the
only factory -fabricated TPO accessories that meet the stringent quality
tolerances required to be included in a Carlisle warranted roofing system.
Features and Benefits
• Every T -Joint cover is a perfect 4.5" diameter circle
• More consistent appearance than hand -cut flashing
N Provides substantial labor savings compared to field -cut flashing
m Seals channels at splice intersections created by seam step -offs
06.11.13 ® 2013 Carlisle.
REPRINT CODE: 604458 - "Sure -Weld T -Joint Covers Product Data Sheet°
CARLISLE
Certified
Fabricated
Accessory
Installation
SYNTEC SYSTEMS
1. If membrane has been exposed to the weather, clean splice
intersection area with Weathered Membrane Cleaner.
2. Use a lower temperature setting on the hand heat welder than that
used for welding reinforced TPO membrane. (Typically a setting of "6"
on a scale of "10" is appropriate for welding TPO T -Joint Covers.)
3. Center the T -Joint Cover over the splice intersection, begin welding
at the center point and work towards the outside. Use the edge of the
roller to crease the T -Joint cover into membrane step -offs to achieve
a proper seal.
4. Using a probe, check all splices for voids and cold welds only once the
T -Joint Cover has completely cooled. Make any needed repairs.
Review Carlisle specifications and details for complete installation
information.
Precautions
The TPO T -Joint Cover is not intended to overlay fasteners and plates
as this requires the use of reinforced membrane.
Store T -Joint Covers in a cool, shaded area and cover with light-
colored, breathable, waterproof tarpaulins. T -Joint Covers that have
been exposed to the weather must be prepared with Weathered
Membrane Cleaner before hot-air welding.
Typical Properties and Characteristics
Size
Thickness
4.5" (114 mm)
0.060" (1.5 mm)
Packaging 100 per box
Weight (per box) ! 3.5 lbs. (1.6 kg)
Material I Non -Reinforced TPO
Color White. Gray, Tan
Typical properties and characteristics are based on samples tested and are not guaranteed
for all samples of this product. This data and information is intended as a guide and does not
reflect the specification range for any particular property of this product.
800-479-6832 1 P.O. Box 7000 I Carlisle, PA 17013 1 Fax: 717-245-7053 I www.cariislesyntec.com
Carlisle and Sure -Weld are trademarks of Carlisle.
EXPERIENCE THE CARLISLE DIFFERENCE
SYNTEC SYSTEMS
Weathered Membrane Cleaner
Overview
Let Carlisle simplify your next EPDM or TPO installation with Weathered
Membrane Cleaner. Weathered Membrane Cleaner is used to clean both
new and in-service Sure -Seal', Sure -White® and Sure -Tough® EPDM
membranes and Sure -Weld's TPO membrane prior to the seaming process.
It helps to loosen and remove dirt and other contaminants from the surface
of the EPDM and TPO membranes and leaves a suitable surface for welding
or the subsequent application of primer. Weathered Membrane Cleaner
should be used when preparing EPDM membranes for application of primer,
adhesives, SecurTAPE'", Factory -Applied Tape'" (FAT) and flashing. Do not
use Weathered Membrane Cleaner on PVC membranes—instead use PVC
Membrane Cleaner.
Features and Benefits
» Easily removes dirt and other contaminants from EPDM and TPO
membranes
» Prepares EPDM membrane for application of primer, adhesives and tape
» Prepares aged or contaminated TPO membrane for welding
Coverage Rate
Coverage rate depends on the age of the membrane and the amount of
dirt/debris on the surface. Assume 400 ft2 (37 m2) (one surface) per
gallon.
Application
EPDM
1. Remove as much loose material as possible from the membrane
surface where the adhesive or pressure -sensitive product will be
applied by brooming or wiping the area with a dry rag. Extreme
conditions of accumulated dirt may require a low sudsing detergent
and water cleaning (rinse area thoroughly with CLEAN water and
allow to dry).
2. Saturate a clean HP Splice Wipe (or equivalent) with Weathered
Membrane Cleaner. SCRUB the area in a circular motion. Continue
to clean the area, changing wipes frequently, until the surface is a
consistent color with no streaking. Additional cleaning is required at
factory seams (scrub parallel to the seam). Allow to dry.
3. Apply primer according to product instructions and/or roofing
system specification.
TPO
Weathered Membrane Cleaner may be used to remove construction dirt
or to prepare aged TPO membrane prior to welding.
New TPO:
1. Saturate a clean HP Splice Wipe (or equivalent) with Weathered
Membrane Cleaner.
2. Wipe the area to be cleaned until the membrane is a consistent
color with no streaking and allow to dry.
3. Weld the cleaned material together with an appropriate hot-air
welder.
Welding Aged Material:
1. Using a Primer Pad and Weathered Membrane Cleaner, scrub the
area to be welded. (The cleaner will become white with membrane
residue during this step of the procedure.)
2. Clean all residue from the area to be welded with an HP Splice Wipe
(or equivalent). Allow to dry.
3. Weld the cleaned material together with an appropriate hot-air
welder.
Review Carlisle specifications and details for complete application
information.
800-479-6832 I P.O. Box 7000 1 Carlisle, PA 17013 I Fax: 717-245-7053 1 www.carlislesyntec.com
EXPERIENCE THE CARLISLE DIFFERENCE
Weathered Membrane Cleaner
Precautions
» Review the applicable Material Safety Data Sheet for complete safety
information prior to use.
» Weathered Membrane Cleaner is EXTREMELY FLAMMABLE. This
product contains materials that are fire and explosion hazards when
exposed to heat, flame or sparks. Store and use away from all sources
of heat, flame or sparks. Do not smoke while applying. Do not use in
a confined or unventilated area. Vapors are heavier than air and may
travel along ground to a distant ignition source and flash back. A red
caution label is required when shipping.
» During application, efforts must be made to prevent fumes from
entering the building via air ventilation ducts. Do not place open
containers or mix adhesive near fresh -air intake units. When possible,
shut down or seal off the closest units.
» Avoid breathing vapors. Keep container closed when not in use.
Use with adequate ventilation. If inhaled, remove to fresh air. If not
breathing, perform artificial respiration. If breathing is difficult, give
oxygen. Call a physician immediately.
» If swallowed, DO NOT INDUCE VOMITING. Call a physician immediately.
• Avoid contact with eyes. Safety glasses or goggles are recommended.
If splashed in eyes, immediately flush eyes with plenty of water for at
least 15 minutes. Contact a physician immediately.
» Avoid contact with skin. Wash hands thoroughly after handling. In case
of contact with skin, thoroughly wash affected area with soap and
water.
Note: Permeation -resistant gloves (that meet ANSI/ISEA 105-2005)
are recommended to be worn when using this product to protect hands
from irritating ingredients.
» KEEP OUT OF THE REACH OF CHILDREN.
SYNTEC SYSTEMS
Typical Properties and Characteristics
Color
Solids
Flash Point
Boiling Point
Clear
0%
65°F (18°C)
260°F (127°C
Packaging 5-gailon (18.9 -liter) closed -top pail
2 x 1 -gallon (3.8 -liter) closed -top pail
Typical properties and characteristics are based on samples tested and are not guaranteed
for all samples of this product. This data and information is intended as a guide and does not
reflect the specification range for any particular property of this product.
LEED Information
Pre -consumer Recycled Content
0%
Post -consumer Recycled Content
0%
Manufacturing Location
Carlisle, PA
VOC Content*
755 grams/liter
'This product is exempt from VOC regulations.
800-479-6832 I P.O. fax 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlisiesyntec.com
09.23.13 2073 Carlisle. Carlisle. Sure -Seal, Sure -Tough, Sure -While, Sure -Weld, SecurTape and Factory -Applied Tape (FAT) are trademarks of Carlisle.
REPRINT CODE: 503626 - "Weathered Membrane Cleaner Product Bata Sheer
LEED is a registered trademark of the U.S. Green Building Council.
EXPERIENCE THE CARLISLE DIFFERENCE
Water Cut -Off Mastic
Overview
Let Carlisle simplify your next membrane installation with its Water Cut -Off
Mastic. Water Cut -Off Mastic is a one -component, low -viscosity, self -
wetting, butyl -blend mastic designed to be used in conjunction with roofing
and waterproofing systems. Itis primarily used as a sealing agent between
various membranes and applicable when membrane is being terminated
using a compression -type seal.
Water Cut -Off Mastic is an extremely tacky material and will remain as
such when used with compression -type terminations.
SYNTEC SYSTEMS
Application
1. All surfaces to be sealed with Water Cut -Off Mastic must be free of
moisture, oil, dirt and other foreign materials. Water Cut -Off Mastic
cannot be used on insulation.
2. Apply a'' /i" (13 mm) bead of Water Cut -Off Mastic between the
substrate and the edge of the membrane.
3. Apply appropriate termination material and secure to provide
constant compression for the Water Cut -Off Mastic.
Review Carlisle specifications and details for complete application
information.
Precautions
» Review the applicable Material Safety Data Sheet for complete safety
information prior to use.
» Water Cut -Off Mastic is FLAMMABLE — contains solvents that are
dangerous fire and explosion hazards when exposed to heat, flame or
sparks. Store and use away from all sources of heat, flame or sparks.
Do not smoke while applying. Do not use in a confined or unventilated
area. Vapors are heavier than air and may travel along ground to a
distant ignition source and flash back.
» Avoid breathing vapors. Keep container closed when not in use.
Use with adequate ventilation, If inhaled, remove to fresh air. If not
breathing, perform artificial respiration. If breathing is difficult, give
oxygen. Call a physician immediately.
If swallowed, DO NOT INDUCE VOMITING. Call a physician immediately.
Avoid contact with eyes. Safety glasses or goggles are recommended.
If splashed in eyes, immediately flush eyes with plenty of clean water
for at least 15 minutes. Contact a physician immediately.
Features and Benefits 3,
Extremely tacky
» Provides a durable compression -type seal between various membranes
and parapet wall constructions
Coverage Rate
10 linear feet per tube at the recommended application rate of a 1/2" bead.
b Avoid contact with skin. Wash hands thoroughly after handling. In case
of contact with skin, thoroughly wash affected area with soap and
water.
Note: Permeation -resistant gloves (that meet ANSI/ISEA 105-2005)
are recommended to be worn when using this product to protect hands
from irritating ingredients.
800-479-6832 1 P.O. Box 7000 1 Carlisle, PA 17013 I Fax: 717-245-7053 1 www.carlislesyntec.com
EXPERIENCE THE CARLISLE DIFFERENCE
Water Cut -Off Mastic
Typical Properties and Characteristics
Color
Gray
Solids
80%
Flash Point
40 F (4 C) Closed Cup
Service Temperature
-40 F to 200 F (-40 C to 93 C)
Specific Gravity
1.29
Cold Weather Flexibility
Excellent
Average Brookfield Viscosity
1,320,000 cps
Packaging
25 tubes/carton
Clean up
Weathered Membrane Cleaner
Average net weight/carton
28 lbs (13 kg)
Shelf life
1 year, unopened container
Typical properties and characteristics are based on samples tested and are not guaranteed
for all samples of this product. This data and information is intended as a guide and does not
reflect the specification range for any particular property of this product.
LEED Information
Pre -consumer Recycled Content
0%
Post -consumer Recycled Content
0%
Manufacturing Location
Carlisle, PA
VOC Content
250 g1L
11.21.13 0 2013 Cerlisle.
REPRINT CODE: 603622 - "Water Cut -Off Mastic Product Data Sheet'
SYNTEC
YSTEA4S
800-479-6832 I P.O. Box 7000 1 Carlisle, PA 17013 1 Fax: 717-245-7053 1 www.carlislesyntec.com
Carlisle and Sure -Seal are trademarks of Carlisle.
LEED is a registered trademark of the U.S. Green Building Council.
EXPERIENCE THE CARLISLE DIFFERENCE
ISure -Weld` TPO
Walkway Rolls
1
Overview
Carlisle's Sure -Weld heat -weldable Walkway Roll is designed to protect
the Sure -Weld TPO membrane in areas exposed to repetitive foot traffic
and other hazards. Walkways must be installed at all traffic concentration
points (i.e, roof hatches, access doors, rooftop ladders, etc.) regardless of
traffic frequency. Walkways must also be installed if regular maintenance
(once a month or more) is necessary to service rooftop equipment.
Carlisle Sure -Weld Walkway Rolls are part of the Certified Fabricated
Accessory (GFA) program. Certified Fabricated Accessories are the
only factory -fabricated TPO accessories that meet the stringent quality
tolerances required to be included in a Carlisle warranted roofing system.
Features and Benefits
Increased slip resistance created with a diamond plate tread pattern
• Walkway edges are trimmed in safety yellow to better define the
designated traffic flow
» The yellow edges are smooth without tread Tugs for easier welding
» Superior weathering package for long term performance
Stocked in white, tan and gray, special colors available (minimum
quantities apply)
Installation
1. Use Weathered Membrane Cleaner to prepare the membrane to be
welded to the walkway material.
2. Position the walkway material. Cut the Walkway Rolls into maximum 10'
lengths and position with a minimum 1" gap between adjacent pieces
to allow for water drainage. Cut the walkway so a 4" minimum gap is
created over any field splices. Since the attachment of the walkway to
the membrane is permanent, this will allow access to the field seams.
01.19.18 0 2018 Carlisle.
REPRINT CODE: 600322- "TPO Walkway Rolls Product Data Sheet"
.4evv� is •
G4RLISLE
SYNTEC SYSTEMS
Certified
Fabricated
Accessory
3. Using an automated welder, weld all four sides of the walkway
material to the membrane. Typically the same speed and
temperature settings will be used for this procedure as for welding
membrane to membrane. A test weld is always recommended prior to
performing welds to the installed membrane. A hand held welder may
be utilized, however, productivity will be decreased.
Review Cadr`sle specifications and details for complete installation information.
Precautions
» Walkway Rolls are a maintenance item and are not covered under the
Carlisle membrane systems warranty.
» This product is to be used as a walkway only and is not designed as a
perimeter warning line or a substitute for ballast. Walkway rolls cannot
be installed within 10' (3m) of the roof perimeter.
» Allow the walkway to relax and warm up in the sun prior to welding
in place.
» When possible, weld the walkway rolls when the ambient temperature
is above 60°F (16° C) to help prevent wrinkles.
Typical Properties
Physical Property
and Characteristics
Test Method Typical Properties
Minimum Maximum
Dimensional Conformance
Thickness, M. (mm)
ASTM D412 0.160 (4.06) 0.180 (4.5)
Density, lbs./ft3; (gr/cm';)
ASTM D792 80.5 (1.29) 84.3 (1.35)
Tensile Strength, psi (MPa)
ASTM 0638 600 (4.1)
Tear Strength, ibf/in (kN/m)
ASTM D624 100 (17.5)
Sizes
34" wide x 50' long
Packaging
9 per skid, each roll individually bagged
Weight (each)
97 lbs.
Thickness
80 -mil at bottom of tread, 80 -mil at yellow
welding edge, 170 -mil overall
Color
White, gray and tan
Typical properties and characteristics are based on samples tested and are not guaranteed
for all samples of this product. This data and Information is Intended as a guide and does not
reflect the specification range for any particular property of this product.
LEED Information
Pre -consumer Recycled Content 10%
Post -consumer Recycled Content 0%
Manufacturing Location
Greenville, IL
800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com
cadtsle and Suro•Wele are trademarks of Gal -lisle.
LEEO is a registered trademark of the U.S. Green Building Council.
CARLISLE
GOLDEN SEAL TOTAL ROOFING SYSTEM WARRANTY
SERIAL NO. 10178056 971
BUILDING OWNER: SEGALE PROPERTIES
NAME OF BUILDING: SEGALE RETAIL - #932
BUILDING ADDRESS: 300 ANDOVER PARK WEST, TUKWILA, WA
DATE OF COMPLETION OF THE CARLISLE TOTAL ROOFING SYSTEM: 01/07/2019
DATE OF ACCEPTANCE BY CARLISLE: 03/28/2019
DATE OF ISSUE: March 28, 2019
oqoic
CMD1252428
Carlisle Roiling Systems, Inc., (Carlisle) warrants to the Building Owner (Owner) of the above described building, that; subject to the terms,
conditions, and limitations stated in this warranty, Carlisle will repair any leak in the Carlisle Golden Seafr"Total Roofing System (Carlisle Total
Roofing System) installed by a Carlisle Authorized Roofing applicator for a period of 20 years commencing with the date of Carlisle's acceptance
of the Carlisle Total Roofing System installation. However, in no event shall Carlisle's obligations extend beyond 20.5 years subsequent to the date
of substantial completion of the Carlisle Total Roofing System. See below for exact date of warranty expiration.
The Carlisle Total Roofing System is defined as the following Carlisle brand materials: Membrane, Flashings, Adhesives and Sealants, Insulation,
Cover Boards, Fasteners, Fastener Plates, Fastening Bars, Insulation Adhesives, and any other Carlisle brand products utilized in this installation.
TERMS, CONDITIONS, LIMITATIONS
1. Owner shall provide Carlisle with written notice via letter, fax or email within thirty (30) days of the discovery of any leak in the Cadisle Total Roofing System. Owner should send written notice of a leak to
Carlisle's Warranty Services Department at the address set forth at the bottom of this warranty. By so notifying Carlisle, the Owner authorizes Carlisle or its designee to investigate the cause of the leak.
Should the investigation reveal the cause of the leak to be outside the scope of this Warranty, investigation and repair costs for this service shall be paid by the Owner.
2. If, upon inspection, Carlisle determines that the leak is caused by a defect in the Carlisle Total Roofing System's materials, or workmanship of the Carlisle Authorized Roofing Applicator in installing the
same, Owners remedies and Carlisle's liability shall be limited to Carlisle's repair of the leak.
3. This warranty shall not be applicable if, upon Carlisle's inspection, Carlisle determines that any of the following has occurred:
(a) The Carlisle Total Roofing System is damaged by natural disasters, including, but not limited to, lightning, fire, insect infestations, earthquake, tornado, hail, hurricanes, and winds of (3 second)
peak gust speeds of fifty-five mph or higher measured at 10 meters above ground; or
(b) Loss of integrity of the building envelope and, or structure including, but not limited to partial or complete loss of roof deddng, wall siring, windows, doors or other envelope components or from
roof damage by wind-blown objects, or:
(c) The Carlisle Total Roofing System is damaged by any intentional or negligent acts, accidents, misuse, abuse, vandalism, civil disobedience, or the like.
(d) Deterioration or failure of building components, including, but not limited to, the roof substrate, walls, mortar, HVAC units, non -Carlisle brand metal work, etc., occurs and causes a leak, or
otherwise damages the Carlisle Total Roofing System; or
(e) Adds, oils, harmful chemicals and the like come in contact with the Carlisle Total Roofing System and cause a leak, or otherwise damage the Carlisle Total Roofing System.
(f) The Carlisle Total Roofing System encounters leaks or is otherwise damaged by condensation resulting from any condition within the building that may generate moisture.
4. This Warranty shall be null and void if any of the following shall occur.
(a) If, after installation of the Carlisle Total Roofing System by a Carlisle Authorized Roofing Applicator there are any alterations or repairs made on or through the roof or objects such as, but not
limited to, structures, fixtures, solar panels, wind turbines, roof gardens or utilities are placed upon or attached to the roof without first obtaining written authorization from Carlisle; or
(b) Failure by the Owner to use reasonable care in maintaining the roof, said maintenance to include, but not be limited to, those items listed on Carlisle's Care 8 Maintenance Information sheet
which accompanies this Warranty. -
5. Only Carlisle brand insulation products are covered by this warranty. Carlisle specifically disclaims liability, under any theory of law, for damages sustained by or caused by non -Carlisle brand insulation
products.
6. During the term of this Warranty, Carlisle shall have free access to the roof during regular business hours.
7. Carlisle shall have no obligation under this Warranty while any bills for installation, supplies, service, and warranty charges have not been paid in full to the Carlisle Authddzed Roofing Applicator,
Carlisle, or material suppliers.
8. Carlisle's failure at any time to enforce any of the terms or conditions stated herein shall not be construed to be a waiver of such provision.
9. Carlisle shall not be responsible for the cleaniness or discoloration of Carlisle Total Roofing System caused by environmental conditions including, but not limited to, dirt,
pollutants or biological agents.
10. Carlisle shall have no liability under any theory of law for any claims, repairs, restoration, or other damages including, but not limited to, consequential or incidental damages relating, directly or
indirectly, to the presence of any irritants, contaminants, vapors, fumes, molds, fungi, bacteria, spores, mycotoxins, or the like in the building or in the air, land, or water serving the building.
11. This warranty shall be transferable upon a change in ownership of the building when the owner has completed certain procedures including a transfer fee and an inspection of the Roofing System by a
Carlisle representative.
CARLISLE DOES NOT WARRANT PRODUCTS UTILIZED IN THIS INSTALLATION WHICH IT HAS NOT FURNISHED; AND SPECIFICALLY DISCLAIMS LIABILITY,
UNDER ANY THEORY OF LAW, ARISING OUT OF THE INSTALLATION AND PERFORMANCE OF, OR DAMAGES SUSTAINED BY OR CAUSED BY, PRODUCTS
NOT FURNISHED BY CARLISLE OR THE PRIOR EXISTING ROOFING MATERIAL OVER WHICH THE CARLISLE ROOFING SYSTEM HAS BEEN INSTALLED.
THE REMEDIES STATED HEREIN ARE THE SOLE AND EXCLUSIVE REMEDIES FOR FAILURE OF THE CARLISLE TOTAL ROOFING SYSTEM OR ITS
COMPONENTS. THERE ARE NO WARRANTIES EITHER EXPRESSED OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR
PURPOSE AND MERCHANTABILITY, WHICH EXTEND BEYOND THE FACE HEREOF. CARLISLE SHALL NOT BE LIABLE FOR ANY INCIDENTAL,
CONSEQUENTIAL OR OTHER DAMAGES INCLUDING, BUT NOT LIMITED TO, LOSS OF PROFITS OR DAMAGE TO THE BUILDING OR ITS CONTENTS UNDER
ANY THEORY OF LAW.
SEE ENCLOSED REFLECTIVITY ADDENDUM FOR FURTHER TERMS, CONDITIONS, AND LIMITATIONS.
BY: Mark J. Long
AUTHORIZED SIGNATURE
TITLE: Director, Technical and Warranty Services
This Warranty Expires: March 27, 2039
RECEIVED
CITY OF TUKWILA
MAY 162019
Ii I'
P.O. Box 7000 Carlisle, PA 17013 Phone: 800.233.0551 Fax: 717,245.7121 www.carlistesyntec.com
F0001 (3/18)
r
SERIAL NO. 10178056 971
NAME OF BUILDING: SEGALE RETAIL - #932
BUILDING ADDRESS: 300 ANDOVER PARK WEST, TUKWILA, WA
DATE OF ISSUE: March 28, 2019
REFLECTIVITY PERFORMANCE AMENDMENT
Subject to all of the warranty terms of the Carlisle System Warranty, Carlisle warrants
that the Carlisle brand white Sure -Weld (TPO) membrane utilized in this installation will
meet the "Energy Star" reflectivity rating of .65 when originally installed and a .50
reflectivity rating thereafter for a total period of ten (10) years from the date of
installation. During this ten (10) year amendment period, the roof must positively drain
and be free of pollutants, grease, oil, and the like. The owner must follow all membrane
deaning recommendations made by Carlisle in the care and maintenance sheet, which
accompanies this warranty. Any change in the use of this building, which adversely
affects the deanliness of the membrane, will nullify this amendment.
In order to make a daim under this warranty amendment, the Owner must thoroughly
dean the membrane and send a representative sample to Carlisle. If, upon inspection by
Carlisle, the membrane reveals a reflectivity rating below the warranted level, Carlisle will
attempt to restore the membrane to its warranted reflectivity rating. Should Carlisle be
unable to restore the warranted reflectivity rating, Carlisle's liability and Owner's remedy
is limited to a credit to be applied towards the purchase of a new membrane; the value of
that credit being determined by Carlisle based upon the number of remaining months of
this warranty amendment used to pro -rate at the current price for the membrane. The
maximum pro -rated value of the credit shall not exceed the original purchase price of the
membrane.
P.O. Box 7000 Carlisle, PA 17013 Phone: 800.233.0551 Fax: 717.245.7121 www.carlislesynlec.com
WA -F0023 (05/13)
5/2/2019
City of Tukwila
Department of Community Development
CURTIS CAMPISTEGUY
PO BOX 88028
TUKWILA, WA 98138
RE: Permit No. D18-0168
SEGALE PROPERTIES
300 ANDOVER PARK W
Dear Permit Holder:
Allan Ekberg, Mayor
Jack Pace, Director
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric
Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null
and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if
the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180
days. Your permit will expire on 6/4/2019.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each
inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire.
Address your extension request to the Building Official and state your reason(s) for the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 6/4/2019, your permit will become null and void
and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sin
erely,
of
K6ndace Nichols
Permit Technician
File No: D18-0168
6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
City of Tukwila
Allan Ekberg, Mayor
Department of Community Development - Jack Pace, Director
December 2, 2018
Curtis Campisteguy
PO Box 88028
Tukwila, WA 98138
RE: Request for Extension #1
Permit Number D18-0168
Dear Ms. Campisteguy,
This letter is in response to your written request for reopening expired Permit D18-0168. The Building
Official, Jerry Hight, has reviewed your letter and considered your request to extend the above
referenced permit. It has been determined that the City of Tukwila Building Division will be granting an
extension to the permit through June 4, 2019.
If you should have any questions, please contact our office at (206) 431-3670.
Sincerely,
Pp)19
V
Rachelle Ripley
Permit Technician
File: Permit No. D18-0168
Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov
SCEGALE PROPERTIES
A LIMITED LIABILITY COMPANY
COMMERCIAL INDUSTRIAL
November 28, 2018
Bill Rambo
Permit Technician
City of Tukwila
6300 Southcenter Blvd #100
Tukwila, WA 98188
Re: Permit #D18-0168
Dear Bill,
AGRICULTURAL NATURAL RESOURCES
Please accept this letter as written request for a 180 -day extension for permit D18-0168.
Due to inclement weather, the project has had to be postponed multiple times. We expect
the project to be completed by the end of December.
We appreciate your assistance in this matter. Please contact me with any questions.
Sincerely,
SEGALE PROP IES
Curtis Campisteguy
Request for Extension #
Current Expiration Date: 41 I D
Extension Request:
W Approved for / f I days
Denied (provide explanation)
Signature "nitials __
RECEIVED
CITY OF TUKWILA
NOV 2 8 2018
PERMIT CENTER
PO BOX 8 8 0 2 8 • TUKWILA, WA 9 8 1 3 8 • 5 8 1 1 SEGALE PARK DRIVE C • TUKWILA, WA 9 8 1 8 8
P 2 0 6. 5 7 5. 2 0 0 0 • F 2 0 6. 5 7 5. 1 8 3 7 • www.segaleproperties.com
11/1/2018
City of Tukwila
Department of Community Development
CURTIS CAMPISTEGUY
PO BOX 88028
TUKWILA, WA 98138
RE: Permit No. D18-0168
SEGALE PROPERTIES
300 ANDOVER PARK W
Dear Permit Holder:
Allan Ekberg, Mayor
Jack Pace, Director
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric
Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null
and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if
the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180
days. Your permit will expire on 12/4/2018.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each
inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire.
Address your extension request to the Building Official and state your reason(s) for the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 12/4/2018, your permit will become null and void
and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Bill Rambo
Permit Technician
File No: D18-0168
6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
PERMIT COORS COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: D18-0168 DATE: 05/30/18
PROJECT NAME: SEGALE PROPERTIES
SITE ADDRESS: 300 ANDOVER PARK W
X Original Plan Submittal
Response to Correction Letter #
Revision # before Permit Issued
Revision # after Permit Issued
DEPARTMENTS:
L 5-31--c€
1
Building Division
Public Works
n
A11,4- 3H6
Fire Prevention Planning Division
Structural
nPermit Coordinator
n
PRELIMINARY REVIEW:
Not Applicable n
(no approval/review required)
DATE: 05/31/18
Structural Review Required
REVIEWER'S INITIALS: DATE:
El
APPROVALS OR CORRECTIONS:
Approved
Corrections Required
(corrections entered in Reviews)
DUE DATE: 06/28/18
Approved with Conditions 71
Denied
(ie: Zoning Issues)
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
12/18/2013
SEGAI_; PROPERITIES LLC
Home Espanol Contact
Safety & Health Claims & Insurance
C4iiWashington State Department of
Labor & Industries
Page 1 of 2
Search L&I
A-7, Index Heip My L&I
Workplace Rights Trade & Licensing
SEGALE PROPERITIES LLC
Owner or tradesperson
Principals
SEGALE, MARIO A, PARTNER/MEMBER
SEGALE, MARIO A, AGENT
Doing business as
SEG))_E PROPERITIES LLC
WA UBI No.
602 0^3 533
PO BOX 88028
TUKWILA, WA 98138-2028
206-575-2000
KING County
Business type
Limited Liability Company
Governing persons
LISA
M
ATKINS
TINA A COVEY;
DEVELOPMENT METRO LAND;
TERESA NADEAU;
NITA L SEGALE;
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
Meets current requirements.
License specialties
GENERAL
License no,
SEGALPL902CQ
Effective — expiration
02/18:2010— 05/01/2020
Bond
SAFFDO INS CO OF AM
Bond account no.
6115'46
$12,000.00
Received by L&I Effective date
03/28.7002 02/18/2010
Expiration date
Until Canceled
Insurance
Alaska National Insurance Co $1,000,000.00
Policy no.
18DLS31006
Received by L&I Effective date
03/30/2018 04/01/2018
Expiration date
04/01/2019
Insurance history
Help us improve
haps://s ;cure.lni.wa.gov/verify/Detail.aspx?UBI=602023533&LIC=SEGALPL902CQ&SAW= 6/1/2018
S:\Facilities\Retail Center\Building\Facilities\Drawings\Cad\Retail Center\932 ReRoof Permit.dwg, 5/29/2018 11:19:32 AM, Canon iPF780
30'-0" —f— 35'-0" —1
410'-3"
,f<5N^,
0 �ti
0'
f-0.
be
PARCEL NO.: 262304 9001
ROOF AREA:
125,744 SQUARE FEET
EXISTING ROOF SYSTEM:
METAL DECKING
R -I9 RIGID INSULATION
JP STEVENS "HI -TUFF" SINGLE -PLY ROOF MEMBRANE
ROOF ACCESS
NEW ROOF SYSTEM:
60 MIL TPO SINGLE -PLY MEMBRANE MECHANICALLY ATTACHED OVER EXISTING ROOF SYSTEM.
4" DENS DECK INSTALLED WHERE SLOPE EXCEEDS i" PER 12".
ROOF RATING:
EXISTING CLASS "A" CLASSIFICATION TO BE MAINTAINED WITH NEW MEMBRANE INSTALLATION.
11C
7.5 TON
11B
12.5 TON
11A
12.5 TON
10C
7.5 TON
10B
12.5 TON
10A
12.5 TON
SKYLIGHTS
I®!
9C
7.5 TON
9B
12.5 TON
9A
12.5 TON
0
8C RAISE CURBS ON EXISTING HVAC 6C
7.5 TON UNITS WHERE REQUIRED 12.5 TON
8B 7B 6B
12.5 TON 12.5 TON 12.5 TON
8A
12.5 TON
ROOF PLAN
470'-0"
7A
12.5 TON
IA
6A
12.5 TON
79'-114
5B
7.5 TON
5A
7.5 TON
VI El
ROOF ACCESS
4B
7.5 TON
4A
12.5 TON
FILE COPY
Permit No.
Plan review approval is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Field Copy : • d . re s is acknowledged:
r'y
By:
Date: 6
City of Tukwila
BUILDING DIVISION
REVISIONS
No changes shall be made to the Scoop
of wo.rI< without prior approval of
Tzi!o.vila Building Division.
,sb, t°!OTE: R visions will require a new plan submittal
and may include additional plan reviewfees,
12.5
TON
" TE PERMIT
illED FOR:
h. I,4:achanical
1/1•Ctectrlcai
firPtumbing
Midas Piping
City of Tukwila
DUILDING DIVISION
A05
SEGALE RETAIL CENTER
VICINITY MAP
NTS
REVIEWED FOR
CODE COMPLIANCE
APP aOVLD
JUN 012010
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
MAY 302018
PERMIT CENTER
168
PROPERTIES
300 Andover Park West
PROJECT NUMBER:
X
0'
co
co
co^
.coOs to
c0 a—
D
N n r-
! Q in
co J
! O
co
� � X
Q * LL
*
U
O
J uJ O
Y � N
~
* a�
m 0
111
CO J aj
co < Z
O
LIJ
O U)�
CO W
O W
a_ 101. 1-
DRAWING NUMBER:
SHEET: f OF: 1
WWW.SEGALEPROPERTIES. COM
c0
0
cV
] r i
0