Loading...
HomeMy WebLinkAboutPermit D18-0168 - SEGALE PROPERTIES - MEMBRANESEGALE PROPERTIES 300 ANDOVER PARK W D18-0168 Parcel No: Address: 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 2623049001 Permit Number: D18-0168 300 ANDOVER PARK W COMPLEX Issue Date: 6/1/2018 Permit Expires On: 11/28/2018 Project Name: SEGALE PROPERTIES Owner: Name: SEGALE PROPERTIES LLC Address: PO BOX 88028 , TUKWILA, WA, 98138 Contact Person: Name: CURTIS CAMPISTEGUY Address: PO BOX 88028 , TUKWILA, WA, 98138 Contractor: Name; SEGALE PROPERTIES LLC Address: PO BOX 88028 , TUKWILA, WA, 98138 License No: SEGALPL902CQ Lender: Name: SEGALE PROPERTIES LLC Address: PO BOX 88028 , TUKWILA, WA, 98138 Phone: (206) 396-2016 Phone: (206) 575-2000 Expiration Date: 5/1/2020 DESCRIPTION OF WORK: ADD SECOND PLY MEMBRANE OVER EXISTING SINGLE PLY MEMBRANE Project Valuation: $230,263.00 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $4,556.42 Occupancy per IBC: M Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No Permit Center Authorized Signature: Date: 1,0214e_ I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction: or the performance of work. I am authorized to sign and obtain this development permit and e to th ondiiti• s attached to this permit. Signature: Print Name: L.,' a'ri-sNj Date: 6/I /' This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: Prior to final inspection for this building permit, a copy of the roof membrane manufacturer's warranty certificate shall be provided to the building inspector. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 0 o PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0103 PRE-REROOF CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. b( 6 -016g Project No. Date Application Accepted: Date Application Expires: l� -U-(i3 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 2623049001 Site Address: 300 Andover Park W Tenant Name: Segale Properties LLC Suite Number: PROPERTY OWNER Name: Curtis Campisteguy Address: P 0 Box 88028 Name: Segale Properties LLC Phone: Fax: 206-575-2000 City: Tukwila State: WA Address: P 0 Box 88028 Phone: 206-396-2016 Fax: Phone: 206-973-5423 Fax: City: Tukwila State: WA Zip: 98138 CONTACT PERSON — person receiving all project communication Name: Curtis Campisteguy Address: P 0 Box 88028 Address: P 0 Box 88028 Phone: Fax: 206-575-2000 City: Tukwila State: WA Zip: 98138 Phone: 206-396-2016 Fax: Phone: 206-973-5423 Fax: Email: curtisc@segaleproperties.com Email: dalek@engineersNW.com GENERAL CONTRACTOR INFORMATION Company Name: Segale Properties LLC Address: P 0 Box 88028 City: Tukwila State: WA Zip: 98138 Phone: Fax: 206-575-2000 Contr Reg No.: SEGALPL902CQ Exp Date: 5-1-2020 Tukwila Business License No.: BUS -0101320 H:\Applications\Fmms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Floor: New Tenant: 0 Yes ..No ARCHITECT OF RECORD Company Name: Engineers Northwest Inc., P.S. Engineer Name: Dale Kaemingk Company Name: N/A City: Seattle State: WA Architect Name: Phone: 206-973-5423 Fax: Email: dalek@engineersNW.com Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Company Name: Engineers Northwest Inc., P.S. Engineer Name: Dale Kaemingk City: •TUk t,,,,(4/ c State: `4/:I Zip: "1 m Address: 9725 Third Avenue NE City: Seattle State: WA Zip: 98115 Phone: 206-973-5423 Fax: Email: dalek@engineersNW.com LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Self Funded 1C LI 1'e_ ewer -Pt -I- / Address: S gl/ 54 is j r�C djl,_ (- City: •TUk t,,,,(4/ c State: `4/:I Zip: "1 m Page 1 of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 230,263.00 Describe the scope of work (please provide detailed information): Add second ply membrane over existing single ply membrane. Will there be new rack storage? ❑ Yes Existing Building Valuation: $ ®.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Foims-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC lat Floor 112,251 2'id Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Foims-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O7O Signature: Print Name: RIED AGENT: Curtis J. Campisteguy Mailing Address: PO Box 88028 H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Date: 5-29-2018 Day Telephone: 206-396-2016 Tukwila WA 98138 City State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK I PAID $4,556.42 D18-0168 Address: 300 ANDOVER PARK W COMPLEX Apn: 2623049001 $4,556.42 DEVELOPMENT $4,422.54 PERMIT FEE R000.322.100.00.00 0.00 $2,677.60 PLAN CHECK FEE R000.345.830.00.00 0.00 $1,740.44 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $133.88 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R14611 R000.322.900.04.00 0.00 $133.88 $4,556.42 Date Paid: Wednesday, May 30, 2018 Paid By: SEGALE PROPERTIES LLC Pay Method: CHECK 645387 Printed: Wednesday, May 30, 2018 11:36 AM 1 of 1 CRWYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit Permit Inspection Request Line (206) 438-9350 Dvi5 oa- jil PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431- Project:�,.�,,� .3E6 e(20-Pj11��"3G Type of Inspection: -IR r.2 Ai— Address:Date 3Q19 AN�I/.�t, PAA4A - I/J Called: Special Instructions: 0e-0ooe Date Wanted: c .m,. 3-"l1 -I`? p.m. Requester: G.) -r, Phone No: '(m 39 (o 2occ' Approved per applicable codes. El Corrections required prior to approval. OMMENTS: as1/4)67, ARG Inspector: Date: ‘10\ n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be ti paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit D1F�-x168' PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: e. it_Vl-► App of Ins ion: Pre- e Role Add: 3CVA0c6iteP4AC Date Called. Special Instructions: ‘---PI M Date Wanted: m. Requester: S Phone No: 2o& -34,-2.D/6 / - Approved per applicable codes. orrections required prior to approval. COMMENTS: Reoc 1e45 L dJ L ettitpc n � i ` PJekSc (c — Cat l I vs w P.aar lg ✓�.Qy fes✓ Over Cry, Inspector: ....01)(-1..a, Date:/ 7 zy/ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. NWSTRLJCTURAt. ENGINEERS Engineers Northwest Inc., P.S. April 5, 2018 SEGALE PROPERTIES 5811 Segale Park Drive C Tukwila, WA 98188 Attn: Steve Nelson r Re: Segale Retail Center — Tukwila, WA 300 Andover Park West Roof Membrane Addition Steve, LU REVIEWED FOR CODE COMPLIANCE APPROVED JUN 01 2018 BUILDof Tukwila NG DIVISION It is my understanding that you are anticipating a roof repair for Segale Retail Center at 300 Andover Park West, Tukwila, WA. As you know, this building, built in 1993, has a steel framed roof structure with a single ply roof system. understand you will be adding a new 60 mil T.P.O. membrane that weighs only about one pound per square foot. Section 707.2 of the 2015 International Building Code allows for a 5% increase in the dead Toad on the roof without requiring modification to the original structural members. As you are effectively adding very little dead load on the roof, it is my opinion that the existing roof structure is adequate to support the new roof membrane addition. Please feel free to call if you have any questions. Sincerely, ENGINEERS f .Of7HWEST, INC., P.S. •. A Dale KaemingkP.E., S. Principal DK:bs ENW Job No. CITY OF TUKWILA MAY 302018 PERMIT CENTER bt8O(8 Engineers Northwest, Inc., P.S. • Structural Engineers • 9725 Third Avenue NE • Seattle, WA 98115 • 206.973.5423 • fax 206.522.6698 C4RLIHLE: April 5, 2018 Stafani Christian Rainbow Federal, Inc. PO Box 1116 Carnation, WA 98014 Re: Segale Retail To Whom It May Concern: flLU This letter is to acknowledge the UL Fire Classification with the Segale Retail project. The existing Hypalon roof system is as follows; Deck: Insulation: Membrane: Steel Deck. Polyisocyanurate insulation (R-19). Hypalon membrane mechanically attached to the deck. The proposed recover includes installing Carlisle's 60 -mil Sure -Weld TPO membrane mechanically attached directly over the existing Hypalon roof system. The existing UL Fire Classification will be maintained up to a %2" in 12" slope. If you have any questions or require additional information, please contact our office. Sinceerely, sot fir el7U,ex/' Brandon M. Maag Design Analyst Carlisle SynTec Systems Cc; S. Silcock — Harper Winn, Inc. REVIEWED FOR CODE COMPLIANCE APPROVED JUN 01 2018 1 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 30 2018 PERMIT CENTER bt�-oi6e P.0. Bat 7003 Carsas!e, PA 17013 Pharr:800.470.6832 Fax 717.245.7053 www.cart,le-svrtec.cmn TRANSMITTAL OF SHOP DRAWINGS, EQUIPMENT DATA, MATERIAL SAMPLES, OR MANUFACTURER'S CERTIFICATES OF COMPLIANCE SECTION 1 - REQUEST FOR APPROVAL OF THE FOLLOWING ITEMS (This section will be initiated by the contractor) 3/29/2018 TRANSMITTAL #: 1 Segale Properties 18205 Andover Park West Tukwila, WA 98188 FROM: Rainbow Federal, Inc. P.O. Box 1116 Carnation, WA 98014 rILE Project Title & Location: Segale Retail 300 Andover Park West Tukwila, WA 98188 CHECK ONE: X THIS IS A NEW TRANSMITTAL THIS IS A RESUBMITTAL OF TRANSMITTAL CONTRACT#: ITEM NO. DESCRIPTION OF ITEM SUBMITTED MFG. OR CONTR. CAT., CURVE DRAWING OR FRnrl-II IRF Nn NO. OF COPIES CONTRACT REFERENCE DOCUMENT SPEC. DRAWING PARA, NO. SHEET NO. a. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 b. c. d. e. f. FOR CONTRAC TOR USE r .nni VARIATION g. h. Carlisle Approve Applicator Letter 20 -year Total System Warranty Letter 1 Sample 1 Sure -Weld TPO Membrane (60 mil for horizontal and 45 mil for vertical) Data 1 Fasteners and Plates Data 1 Non -Reinforced Membrane Data 1 Bonding Adhesive - for vertical applications Cut Edge Sealant Data 1 Data 1 TPO Clad Metal - for scupper fabrication Pipe Boots Data 1 Data 1 Inside Corners Outside Corners T -Joint Covers REVIEWED FOR Data 1 CODE COMPLIANCE-. Cleaner APPROVED Data 1 Data 1 Data 1 CITY ROF TUKWIL.A MAY 30 2018 Water Cut Off Mastic JUN 01 2018 Data 1 Walkpad Data 1 PERMIT CENTER REMARKS: City of Tukwila BUILDING fIVISiON Stefani Christian NAME AND SIGNATURE OF CONTRACTOR ENCLOSURES RETURNED (List by Item number) SECTION 11 - APPROVAL ACTION NAME, TITLE AND SIGNAT OF APPROVING AU ITY 4rr1M+ C4RLISLE March 29, 2018 Rainbow Federal, Inc. P.O. Box 1116 Carnation, WA 98014 Project: Segale Retail Attn: Steve Nelson, 1 Customer#: 203146 This letter is to confirm that Rainbow Federal, Inc. of Carnation, WA has been a Carlisle Authorized Applicator in good standing since 1998. Since becoming an Authorized Applicator, Rainbow Federal, Inc. has installed 97 warranted projects totaling over 5.5mm square feet. Please feel free to contact me should you have any further questions. Sincerely, qac Paeoft Ryan Paxton North West District Sales Manager PJ 6a7C"� far, FA 17013 PT -7n= CC3 4/ 6x.32 Fax 457r53 wrrrca:it:`e-:imec.ct. CARLISLE )+00/1 6o�N Sou TOTALROOFING SYsrEM Waiii�Y SERIAL NO. DATE OF ISSUE: BUILDING OWNER: NAME OF BUILDING: BUILDING ADDRESS: DATE OF COMPLETION OF THE CARLISLE TOTAL ROOFING SYSTEM: DATE OF ACCEPTANCE BY CARLISLE: Carlisle Roofing Systems, Inc., (Carlisle) warrants to the Building Owner (Owner) of the above described building, that; subject to the terms, conditions, and limitations stated in this warranty, Carlisle will repair any leak in the Carlisle Golden SeaP Total Roofing System (Carlisle Total Roofing System) installed by a Carlisle Authorized Roofing applicator for a period of20years commencing with the date of Carlisle's acceptance of the Carlisle Total Roofing System installation. However, in no event shall Carlisle's obligations extend beyond years subsequent to the date of substantial completion of the Carlisle Total Roofing System. See below for exact date of warranty expiration. The Carlisle Total Roofing System is defined as the following Carlisle brand materials: Membrane, Flashings, Adhesives and Sealants, Insulation, Cover Boards, Fasteners, Fastener Plates, Fastening Bars, Metal Work, Insulation Adhesives, and any other Carlisle brand products utilized in this installation. TERMS, CONDITIONS, LIMITATIONS 1. Owner shall provide Carlisle with written notice via letter, fax or email within thirty (30) days of the discovery of any leak in the Carlisle Total Roofing System. Owner should send written notice of a leak to Carlisle's Warranty Services Department at the address set forth at the bottom of this warranty. By so notifying Carlisle, the Owner authorizes Carlisle or its designee to investigate the cause of the leak. Should the investigation reveal the cause of the leak to be outside the scope of this Warranty, investigation and repair costs for this service shall be paid by the Owner. 2. If, upon inspection, Carlisle determines that the leak is caused by a defect in the Carlisle Total Roofing System's materials, or workmanship of the Carlisle Authorized Roofing Applicator in installing the same, Owner's remedies and Carlisle's liability shall be limited to Carlisle's repair of the leak. 3. This warranty shall not be applicable if, upon Carlisle's inspection, Carlisle determines that any of the following has occurred: (a) The Cadiste Total Roofing System is damaged by natural disasters, including, but not limited to, lightning, fire, insect infestations, earthquake, tornado, hail, hurricanes, and winds of (3 second) peak gust speeds of mph or higher measured at 10 meters above ground; or (b) Loss of integrity of the building envelope and, or structure including, but not limited to partial or complete loss of roof decking, wall siding, windows, doors or other envelope components or from roof damage by wind-blown objects, or. (c) The Carlisle Total Roofing System is damaged by any intentional or negligent acts, accidents, misuse, abuse, vandalism, civil disobedience, or the like. (d) Deterioration or failure of building components, including, but not limited to, the roof substrate, walls, mortar, HVAC units, non -Carlisle brand metal work, etc., occurs and causes a leak, or otherwise damages the Cadiste Total Roofing System; or (e) Acids, oils, harmful chemicals and the like come in contact with the Carlisle Total Roofing System and cause a leak, or otherwise damage the Carlisle Total Roofing System. (t) The Carlisle Total Roofing System encounters leaks or is otherwise damaged by condensation resulting from any condition within the building that may generate moisture. 4. This Warranty shall be null and void if any of the following shall occur. (a) If, after installation of the Carlisle Total Roofing System by a Carlisle Authorized Roofing Applicator there are any alterations or repairs made on or through the roof or objects such as, but not limited to, structures, fixtures, solar panels, wind turbines, root gardens or utilities are placed upon or attached to the roof without first obtaining written authorization from Carlisle; or (b) Faiture by the Owner to use reasonable care in maintaining the roof, said maintenance to include, but not be limited to, those items listed on Carlisle's Care & Maintenance Information sheet which accompanies this Warranty. 5. Only Carlisle brand insulation products are covered by this warranty. Carlisle specifically disclaims liability, under any theory of law, for damages sustained by or caused by non - Carlisle brand insulation products. 6. During the term of this Warranty, Carlisle shall have free access to the roof during regular business hours. 7. Carlisle shall have no obligation under this Warranty white any bills for installation, supplies, service, and warranty charges have not been paid in full to the Carlisle Authorized Roofing Applicator, Carlisle, or material suppliers. 8. Carlisle's failure at any time to enforce any of the terms or conditions stated herein shall not be construed to be a waiver of such provision. 9. Carlisle shall not be responsible for the cleanliness or discoloration of the Carlisle Total Roofing System caused by environmental conditions including, but not limited to, dirt, pollutants, or biological agents. 10. Carlisle shall have no liability under any theory of law for any claims, repairs, restoration, or other damages including, but not limited to, consequential or incidental damages relating, directly or indirectly, to the presence of any irritants, contaminants, vapors, fumes, molds, fungi, bacteria, spores, mycotoxins, or the like in the building or in the air, land, or water serving the building. 11. This warranty shall be transferable upon a change in ownership of the building when the owner has completed certain procedures including a transfer fee and an inspection of the Roofing System by a Carlisle representative. CARLISLE DOES NOT WARRANT PRODUCTS UTILIZED IN THIS INSTALLATION WHICH IT HAS NOT FURNISHED; AND SPECIFICALLY DISCLAIMS LIABILITY, UNDER ANY THEORY OF LAW, ARISING OUT OF THE INSTALLATION AND PERFORMANCE OF, OR DAMAGES SUSTAINED BY OR CAUSED BY, PRODUCTS NOT FURNISHED BY CARLISLE OR THE PRIOR EXISTING ROOFING MATERIAL OVER WHICH THE CARLISLE ROOFING SYSTEM HAS BEEN INSTALLED THE REMEDIES STATED HEREIN ARE THE SOLE AND EXCLUSIVE REMEDIES FOR FAILURE OF THE CARLISLE TOTAL ROOFING SYSTEM OR ITS COMPONENTS. THERE ARE NO WARRANTIES EITHER EXPRESSED OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY, WHICH EXTEND BEYOND THE FACE HEREOF. CARLISLE SHALL NOT BE LIABLE FOR ANY INCIDENTAL, CONSEQUENTIAL OR OTHER DAMAGES INCLUDING, BUT NOT LIMITED TO, LOSS OF PROFITS OR DAMAGE TO THE BUILDING OR ITS CONTENTS UNDER ANY THEORY OF LAW. BY: Robert H. McNeill AUTHORIZED SIGNATURE TITLE: Director. Technical and Warranty Services This Warranty Expires: P 0, floc 7000 Gat lcxte PA 1 413 Phone. 800.273,9551 Fax: 717.245 7121 Www carne tesvnti c corn WA -F0001 Nth) EXPERIENCE THE CARLISLE DIFFERENCE Sure-WeldTPO Reinforced Membrane Overview Carlisle's Sure -Weld TPO reinforced membrane is a premium, heat - weldable, single -ply Thermoplastic polyolefin (TPO) sheet designed for new roof construction and re -roofing applications. Sure -Weld High Slope (HS) membrane is formulated with additional flame retardant for higher -slope fire code approvals. Sure -Weld EXTRA is 80 mils thick for significantly higher strength and weatherability. Sure -Weld TPO membranes use advanced polymerization technology that combines the flexibility of ethylene -propylene (EP) rubber with the heat weldability of polypropylene. All Sure -Weld TPO membranes include OctaGuard XT"", an industry-leading, state-of-the-art weathering package. OctaGuard XT technology enables Sure -Weld TPO to withstand the extreme weatherability testing that is intended to simulate exposure to severe climates. Physical properties of the membrane are enhanced by a strong polyester fabric that is encapsulated between the TPO-based top and bottom plies. The combination of the fabric and TPO plies provides high breaking and tearing strength, as well as excellent puncture resistance. The relatively smooth surface of the membrane produces a total surface fusion weld that results in a consistent, watertight, monolithic roof assembly. The membrane is environmentally friendly and safe to install. Carlisle's standard and HS TPO membranes are available in highly reflective white, tan, and gray, in both 45 -mil and 60 -mil thicknesses. 80 -mil Sure -Weld EXTRA (including HS) is also offered in white, gray, and tan colors. Special color Sure -Weld TPO membranes are also available (see Carlisle's TPO Color Palette brochure). Carlisle's TPO is offered in 4-, and 6 -ft perimeter sheets and 8-,10-, and 12 -ft Sure -Weld field sheets. Sure -Weld HS and special color TPO membranes are available in limited sizes. Carlisle's tan and white TPO membranes are ENERGY STAR®* -qualified and California Title 24 compliant and can contribute toward LEED® (Leadership in Energy and Environmental Design) credits. CARLISLE SYNTEC SYSTE Productivity Boosting Features and Benefits: Optional APEEL Protective Film Carlisle's Sure -Weld TPO reinforced membrane is available with an optional APEEL Protective Film, saving time and labor by eliminating the need for roof cleaning upon project completion. Carlisle's innovative APEEL Protective Film can be left in place for up to 90 days without affecting the integrity of the film, guarding the TPO membrane's surface from scuffs and dirt accumulation during installation. Durable and easy to remove, APEEL Protective Film improves aesthetics and long-term reflectivity and is ideal for re -roofing, re-cover, and new construction projects. OCTRGURRO XT WEATHERING PACKAGE Features and Benefits » Outstanding puncture resistance » Excellent fire resistant assemblies » Environmentally friendly and stable formulation » Excellent resistance to impact and low temperatures » Excellent chemical resistance to acids, bases and restaurant exhaust emissions » UL 2218 Class 4 hail rating » Exceptional resistance to heat, solar UV, ozone and oxidation » Manufactured using a hot -melt extrusion process for complete scrim encapsulation » 100% recyclable (see Carlisle's Recyclability Statement) Enhanced with the OctaGuard XT weathering package » APEEL Protective Film application guards the TPO membrane's surface from scuffs and dirt accumulation during installation, improving the roof system's appearance and long-term performance • APEEL Protective Film can be left in place for up to 90 days without degrading due to its excellent heat- and UV -resistance 800-479-6832 1 P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 1 www.cartislesyntec.com EXPERIENCE THE CARLISLE DIFFERENCE I Sure -Weld TPO Reinforced Membrane Installation 1. Sure -Weld TPO roofing systems are quick to install, as minimal labor and few components are required. TPO systems are installed using an Automatic Heat Welder, making sheet welding fast, clean, consistent, and easy to learn, while reducing strain on the roofing technician. 2. APEEL Protective Film should be removed from within areas that are to be heat -welded together. In areas that do not require heat - welding, the APEEL Protective Film can be left in place for up to 90 days. When the installation of the entire TPO roofing system is complete, remove and discard the APEEL Protective Film. 3. The Carlisle Mechanically Fastened Roof System installation starts by fastening the insulation with a minimum of 4 fasteners per 4' by 8' board. The membrane is mechanically fastened to the deck using HP -X' Fasteners and Piranha Plates" or HP-XTRA Fasteners and Piranha XTRA Plates. Adjoining sheets of membrane are overlapped over the fasteners and plates and joined together with a minimum 1W -wide (4 cm) hot-air weld. At vertical applications At horizontal applications Typical Properties and Characteristics Physical Property Tolerance on Nominal Thickness, % ASTM 0751 test method Thickness Over Scrim, in. (mm) ASTM 07635 optical method, average of 3 areas Breaking Strength, Ibf (kN) ASTM 06878 Requirement 45 -mil 60 -mil 80 -mit EXTRA +15, -10 0.015 min (0.380) 220 (976 N) ASTM D751 grab min Elongation Break of Reinforcement, % ASTM 0751 grab method Tearing Strength, lbf (N) ASTM 0751 proc.13 8 in. x 8 in. Brittleness Point, °F (°C) ASTM D2137 Linear Dimensional Change, % ASTM 01204, 6 hours at 158°F 15 min 55 (245) min -40 (-40) max ±1 max ± 10 0.018 typical (0.457) 225 (1.0) min 320 (1.4) typical 15 min 25 typical 55 (245) min 130 (578) typical -40 (-40) max -50 (-46) typical ± 1 max -0.2 typical ± 10 ±10 0.024 typical (0.610) 250 (1.1) min 360 (1.6) typical 15 min 25 typical 0.034 typical (0.864) 350 (1.6) min 425 (1.9) typical 15 min 25 typical 55 (245) min 55 (245) min 130 (578) typical 130 (578) typical -40 (-40) max -40 (-40) max -50 (-46) typical -50 (-46) typical -±1 max ± 1 max -0.2 typical -0.2 typical Ozone Resistance, no cracks 7X ASTM D1149, 100 pphm, 168 hrs PASS Water Absorption Resistance, mass % ± 3.0 max ASTM 0471 top surface only 166 hours at 158°F water Factory Seam Strength, Ibf/in (kN/m) ASTM D751 grab method Field Seam Strength, Ibftn (kN/m) ASTM 01876 tested in peel PASS PASS PASS ± 3.0 max 0.90 typical ± 3.0 max 0.90 typical ± 3.0 max 0.90 typical 66 (290) min 66 (290) min 66 (290) min 66 (290) min No requirement 25 (4.4) min 50 (8.8) typical 25 (4.4) min 60 (10.5) typical 40 (7.0) min 70 (12.3) typical Water Vapor Permeance, Perms ASTM E96 proc. B Puncture Resistance, Ibf (kN) FTM 101 C, method 2031 (see supplemental section) �� Properties After Heat Aging __ ASTM 0573, 32 weeks 240°F or 8 weeks @ 275°F No cracking when bent around 3" diameter mandrel Weight Change, % Typical Weights Ib/ftz (kg/m2) No requirement 0.10 max 0.10 max 0.10 max 0.05 typical 0.05 typical 0.05 typical No requirement PASS No cracking ± 1.5 max 250 (1.1) min 300 (1.3) min 400 (1.8) min 325 (1.4) typical 350 (1.6) typical 450 (2.0) typical PASS No cracking 1.0 max PASS No cracking 1.0 max PASS No cracking 1.0 max 0.23 (1.1) 0.29 (1.4) 0.40 (2.0) Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. ISure -Weld TPO Reinforced Membrane 4. The Carlisle Fully Adhered Roofing System installation begins by fastening the insulation at the required density necessary to meet the appropriate warranty or wind load requirement. The substrate and membrane are then coated with an appropriate Sure -Weld TPO bonding adhesive and the membrane is rolled into place. Review Carlisle specifications and details for complete installation information. Precautions » Sunglasses that filter out ultraviolet light are strongly recommended, as tan and white surfaces are highly reflective. Roofing technicians should dress appropriately and wear sunscreen. » Surfaces may become slippery due to frost and ice buildup. Exercise caution during cold conditions to prevent falls. » Care must be exercised when working close to a roof edge when the surrounding area is snow-covered, as the roof edge may not be clearly visible. » Use proper stacking procedures to ensure sufficient stability of the rolls. Exercise caution when walking on wet membrane. Membranes may be slippery when wet. » Store membrane in the original undisturbed plastic wrap in a cool, shaded area and cover with Tight -colored, breathable, waterproof tarpaulins. Membrane that has been exposed to the weather must be prepared with Weathered Membrane Cleaner prior to hot-air welding. » Take care not to stand or place heavy objects on the edge of folded - over membrane, as this could cause a hard crease in the membrane. • Maximum sustained temperature not to exceed 160°F (71°C) for TPO membrane. u Do not use razor blades or other sharp tools to cut the APEEL Protective Film while it is still adhered to the TPO membrane as damage to the underlying membrane may occur. Pull the protective film away from the membrane prior to cutting. » Remove APEEL Protective Film by pulling towards the center of the roof. Do not remove the film by pulling towards the roof edge. » A static electric charge may develop when removing APEEL Protective Film from the surface of the membrane sheet. To avoid the possibility of ignition, lids must be closed on any flammable products and a fire extinguisher should be readily available. » Color membranes will 'fade' aver time mainly due to The ultraviolet portion of sunlight Since most roof surfaces are exposed to variable sunlight, some areas will be more susceptible to color changes caused by UV fading. Warranties for color membranes do not cover fading of colors. G4RL/SLOE SYNTEC SYSTEMS EXTREME Testing for Severe Climates ASTM Standard 06878 is the material specification for Thermoplastic Polyolefin -Based Sheet Roofing. It covers material property requirements for TPO roof sheeting and includes initial and aged properties after heat and xenon -arc exposure. As stated in the scope of the standard, "the tests and property limits used to characterize the sheet are values intended to ensure minimum quality for the intended purpose." Carlisle's goal is to produce TPO that delivers maximum performance for the intended purpose of roofing membranes. Maximum performance requires the membrane to far exceed the requirements of ASTM D6878. Heat Aging accelerates the oxidation rate that roughly doubles for each 18°F (10°C) increase in roof membrane temperature. Oxidation (reaction with oxygen) is one of the primary chemical degradation mechanisms of roofing materials. Carlisle Testing — Heat Aging ASTM TEST 240°F ASTM Requirement Sure -Weld Requirement 32 weeks** >128 weeks **Heat exposure comparable to 3,120 weeks (60 years) at 185°F for 8 hours/day. » Test specimen is a 2" by 6" piece of 45 -mil membrane unbacked, placed in circulating hot-air oven. » Criterion — no visible cracks after bending aged test specimen around 3" -diameter mandrel. Xenon -arc exposes the membrane samples to the combined effect of UV, visible and infrared radiation as well as ozone, heat and water spray to greatly accelerate the effects of outdoor weathering. The radiation dose is measured in kilojoules per square meter (kJ/m2) at 340 nm machine UV wavelength. The irradiance power of the xenon -arc Lamp is measured in watts per square meter (W/m2). Carlisle Testing — Xenon -Arc ASTM TEST Sure -Weld Requirements a� ASTM 06878 45 -mil 60 -mil 80 -mil i Requirement Id/m2 at 340 nm I 10,080 >40,000 >50,000 >60,000 » Test specimen is a 2.75" by 5.5" piece of membrane, unbacked, weathering side facing arc Tamp. » Criterion — no visible cracks when viewed under 7x magnification while wrapped around 3" -diameter mandrel. 800-479-6832 1 P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 i www.carlislesyntec.com EXPERIENCE THE CARLISLE DIFFERENCE Sure -Weld TPO Reinforced Membrane Q -Trac testing combines accelerated weathering with real-world conditions using an array of ten mirrors to reflect and concentrate full spectrum sunlight onto membrane test specimens. The Q -Trac device automatically tracks the sun's path from morning to night. Also, it adjusts to compensate for seasonal changes in the sun's altitude. Eight years in Q -Trac testing is equal to 40 years of real-world exposure. Carlisle requires its Sure -Weld TPO membranes to pass the equivalent of 40 years of exposure in the Q -Trac. Carlisle Testing - Q -Trac ASTM D6878 Requirement Sure -Weld Requirement ASTM TEST N/A N/A Equivalent of 40 years of exposure Environmental Cycling subjects the membrane to repeated cycles of heat aging, hot-water immersion, and xenon -arc exposure. u ASTM requirement - none » Carlisle EXTREME test*: - 10 days heat aging at 240°F (116°C) followed by - 5 days water immersion at 158°F (70°C) followed by - 5,040 kJ/m2 (2000 hours at 0.70 W/m2 irradiance) xenon -arc exposure *Test specimen is 2.75" by 5.5" piece of membrane with edges sealed. *Criterion - after 3 complete cycles, test specimens shall remain flexible and not have any cracking under 10x magnification while wrapped around a 3" -diameter mandrel. Supplemental Approvals, Statements and Characteristics: 1. Sure -Weld TPO meets or exceeds the requirements of ASTM D6878 Standard Specification for Thermoplastic Polyolefin -Based Sheet Roofing. 2. Radiative Properties for ENERGY STAR, Cool Roof Rating Council (CRRC) and LEED. 3. Sure -Weld TPO membranes conform to requirements of the US E.P.A. Toxic Leachate Test (40 CFR part 136) performed by an independent analytical laboratory. 4. Sure -Weld TPO was tested for dynamic puncture resistance per ASTM 05635-04 using the most recently modified impact head. 45 -mil was watertight after an impact energy of 12.5 J (9.2 ft-lbf) and 60 -mil was watertight after 22.5 J (16.6 ft-lbf). 80 -mil EXTRA was watertight after an impact energy of 30.0 J (22.1 ft-lbf). 5. NSF -P151 Certification for rainwater catchment system components. - Plant 91/White Only IMINONINIMMINE SYNTEC SYSTEMS Radiative Properties for ENERGY STAR*, and LEED Solar Reflectance Index (SRI) is calculated per ASTM E1980. The SRI is a measure of the roof's ability to reject solar heat, as shown by a small temperature rise. It is defined so that a standard black (reflectance 0.05. emittance 0.90) is 0 and a standard white (reflectance 0.80, emittance 0.90) is 100. Materials with the highest SRI values are the coolest choices for roofing. Due to the way SRI is defined, particularly hot materials can even take slightly negative values and particularly cool materials can even exceed 100. `ENERGY STAR recommends that using the Roof Savings Calculator (rsc.ornt.gov), which factors in both heating and cooling costs, to determine whether a cool roof will be an energy efficient choice for your geographic climate and building type. LEED Information Pre -consumer Recycled Content 10% Post -consumer Recycled Content 0% Manufacturing Location Senatobia, MS Tooele, UT Carlisle, PA Solar Reflectance Index (SRI) 99 (white) 86 (tan) t CRC 800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com Carlisle, Sure -Weld, OctaGuard XT, APEEL, Piranha Plates and RP -x are trademarks of Carlisle. ENERGY STAR Is a registered trademark awned by the U.S. Government. 'ENERGY STAR qualification is only valid in the U.S. LEED is a registered trademark of the U.S. Green Building Councg. 01.12.18 0 2018 Carlisle. REPRINT CODE: 600515 Sure -Weld TPO Reinforced Membrane Product Data Sheet" Test Method White TPO Tan TPO Gray TPO ENERGY STAR - Initial solar reflectance Solar Spectrum Reflectometer 0.79 0.71 N/A ENERGY STAR - Initial solar reflectance after 3 years Solar Spectrum Reflectometer (uncleaned) 0.70 0.64 N/A CRRC - Initial solar reflectance ASTM C1549 0.79 0.71 0.46 CRRC - Solar reflectance after 3 years ASTM C1549 (uncleaned) 0.70 0.64 0.43 CRRC - Initial thermal emittance ASTM C1371 0.90 0.86 0.89 CRRC - Thermal emittance after 3 years ASTM C1371 (uncleaned) 0.86 0.87 0.88 LEED-Thermal emittance PASS 0.90 0.86 0.85 SRI - Initial (Solar Reflectance Index) 99 86 53 SRI - 3 year aged (Solar Reflectance Index) 85 77 48 Solar Reflectance Index (SRI) is calculated per ASTM E1980. The SRI is a measure of the roof's ability to reject solar heat, as shown by a small temperature rise. It is defined so that a standard black (reflectance 0.05. emittance 0.90) is 0 and a standard white (reflectance 0.80, emittance 0.90) is 100. Materials with the highest SRI values are the coolest choices for roofing. Due to the way SRI is defined, particularly hot materials can even take slightly negative values and particularly cool materials can even exceed 100. `ENERGY STAR recommends that using the Roof Savings Calculator (rsc.ornt.gov), which factors in both heating and cooling costs, to determine whether a cool roof will be an energy efficient choice for your geographic climate and building type. LEED Information Pre -consumer Recycled Content 10% Post -consumer Recycled Content 0% Manufacturing Location Senatobia, MS Tooele, UT Carlisle, PA Solar Reflectance Index (SRI) 99 (white) 86 (tan) t CRC 800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com Carlisle, Sure -Weld, OctaGuard XT, APEEL, Piranha Plates and RP -x are trademarks of Carlisle. ENERGY STAR Is a registered trademark awned by the U.S. Government. 'ENERGY STAR qualification is only valid in the U.S. LEED is a registered trademark of the U.S. Green Building Councg. 01.12.18 0 2018 Carlisle. REPRINT CODE: 600515 Sure -Weld TPO Reinforced Membrane Product Data Sheet" Product Data FASTENERS lit PLATES Carlisle SynTec Systems offers an array of fasteners and plates to complement our roofing systems. From pre -assembled choices for EPDM installations to Purlin fasteners for Metal Retrofit Systems and Piranha plates for Sure -Weld® options, our mission continues to be to provide all components necessary for the application of a long-lasting and secure single -ply roofing system from Carlisle. EPDM Sf Sure -Seale & Sure -White® EPDM Sure -Weld TPO Sure -Flex'" PVC HP FASTENER CD -10 Applicable to steel, 22 -gauge and heavier, CDX plywood and wood plank deck types. Can be used to secure Sure -Tough membranes, RUSS and insulation. Longer fastener sizes available as special order. Sizes Available: 1Y.", 2"-15" (1" Increments) Size & Quantity Per Box: 2"— 6":1,000; 7"-12": 500;13"-15": 250 1'Y4":1000 �EPDh� SWi Pa Applicable for concrete decks. Used to secure Sure -Seal, Sure -Weld and Sure -Flex membranes and for insulation securement. Sizes Available: 2"— 6" (1" Increments) 7"-12" (1" Increments) Size & Quantity Per Box: 2"— 8": 500; 9"-12": 250 HP -X FASTENER*' & HP-XTRA FASTENER Sf� Size & Quantity Per Box: 500 (2" — 6"), 250 (7" — 8") A 415 diameter fastener applicable to steel, wood and CDX plywood. Can be used to secure Sure -Seal, Sure -Weld and Sure -Flex membranes. Sizes Available: 2"-8" (1" Increments) 10"-16" (2" Increments) Size & Quantity Per Box: 2"— 4": 1,000; 5"-12": 500;14"-16": 250 HP-XTRA FASTENER Also Available (Not shown) A 421 diameter fastener applicable to steel, wood and CDX plywood decks. Sizes Available: 2" —8" (1" increments) Expedence the Carlisle Difference lirin-o? INSULFAST"M SURE -TITS® A 412 diameter fastener applicable to wood decks and steel, 22 -gauge and heavier, decks. Used only for insulation attachment. Sizes Available: 2"— 8" (1" Increments) 1%",, 2Y." 3"— 8" (1" Increments) Size & Quantity Per Box: 2"— 8":1,000 HD 14-10 A 0.33" diameter fastener applicable to steel, 22 -gauge and heavier. Can be used for Sure - Tough membrane securement in mechanically attached systems. Sizes Available: 2"-8" (1" Increments) Size & Quantity Per Box: 2", 3": 500; 4"— 8": 250 fPDM SSW 001 St j A 414 diameter fastener used for Sure -Tough, Sure -Weld and Sure -Flex membrane securement into wood and concrete decks. Also applicable to insulation securement into steel, wood and concrete decks. Sizes Available: 2"-12" (1" Increments) 14"— 24" (2" Increments) Size & Quantity Per Box: 2"— 4":1,000; 5" 11": 500; 12"— 24": 250 GYPTEC FASTENER & PLATE EPI# SW goo' rsr 800-479-6832 • P.O. Box 7000 • Carlisle, PA 17013 • Fax: 717-245-7053 • www.carlislesyntec.com Applicable to cementitious wood fiber, lightweight concrete and gypsum decks. Can be used to secure Sure -Tough, Sure -Weld and Sure -Flex membranes and insulation. Sizes Available: 2'h"-10" ('h" increments) Size & Quantity Per Box: 2h"— 7": 500; 7%z"-10": 250 GYPTEC PLATE Sizes Available: 2" Metal membrane plate 3" Metal insulation plate Quantity Per Box: 1,000 svNTHC srsrsnr„ Product Data FASTENERS & PLATES ASAP WITH POLYMER PLATE A pre -assembled #112 diameter fastener and plastic insulation plate applicable to steel and wood decks. Used to secure insulation only. Longer fastener sizes available as special order. Sizes Available: 3"— 12" (1" Increments) Size & Quantity Per Box: 2'A"— 8": 250; 9"-12": 200 HP PRE -ASSEMBLED Pre -assembled HP Fastener and Polymer seam plate applicable to steel, wood and CDX plywood decks. Used to secure Sure -Tough membranes. Sizes Available: 21/4", 3"-12" (1" Increments) Size & Quantity Per Box: 21/4", 3", 31/4', 33/a": 450; 4", 5": 400; 6": 350; 7", 8": 300; 9": 250; 10"— 12": 200 HP POLYMER SEAM PLATE Along with the HP Fastener, used to mechanically fasten reinforced Sure -Tough membrane and RUSS over steel decks. Sizes Available: 2" diameter Quantity Per Box: 1,000 HP-XTRA POLYMER SEAM PLATE Also Available (Not shown) For use with HP-XfRA Fastener to secure Sure -Tough membranes to steel decks. Sizes Available: 23/8" diameter Quantity Per Box: 1,000 SEAM FASTENING PLATE Applicable with HP, HD 14-10 and CD -10 fasteners to mechanically attach reinforced Sure -Tough membrane (excluding steel decks) and RUSS (except when used with mechanically fastened EPDM to steel decks). Sizes Available: 2" diameter Quantity Per Box: 1,000 Experience the Carlisle Difference HP -X ASAP A pre -assembled HP -X Fastener and Piranha PlateTM applicable to steel, wood and CDX plywood decks. Used to secure Sure -Weld and Sure -Hex membranes. Sizes Available: 2"-10" (1" Increments) 12"-16" (2" Increments) Size & Quantity Per Box: 2"— 9": 250;10"-12": 200;14"-16":150 RHINOBOND® PLATE PIRANHA PLATE 3" -round, specially coated plates used with HP -X Fasteners and the RhinoBond induction welding system. Available in TPO and PVC versions. Sizes Available: 3" diameter Quantity Per Box: 500/carton SW Sf Along with the appropriate fastener, used to secure Sure -Weld and Sure -Flex membranes to steel, concrete and wood decks. Sizes Available: 23/a" diameter Quantity Per Box: 1,000 HP-XTRA PIRANHA PLATE Also Available (Not shown) For use with HP-XTRA Fastener to secure Sure -Weld and Sure -Flex membranes to steel and wood decks. Sizes Available: 23/e" diameter Quantity Per Box: 1,000 INSULATION FASTENING PLATE 800-479-6832 • P.O. Box 7000 • Carlisle, PA 17013 • Fax: 717-245-7053 • www.carlislesyntec.com Carlisle, Sura -Seal, Sure -Weld, ReeceBACK Sure -Rex, Sure -White, HP -X Fastener, lnsulFAST, Sure -Tito and RUSS are trademarks of Carlisle. f#rinoeond is a registered trademark of CMG, Inc. REPRMr REQUEST CODE: 600269 - Fasteners & Plates Product Data Sheet - 02.19.13 ® 2013 Carlisle. Applicable with InsulFast, HP, CD -10 and HD 14-10 fasteners. Used for Insulation securement only on steel, wood and concrete decks. Sizes Available: 3" diameter Quantity Per Box: 1,000 SYNTEC SYSTEMS EXPERIENCE THE CARLISLE DIFFERENCE ISure -Weld' TPO Non -Reinforced Flashing Overview Carlisle's Sure -Weld TPO Non -Reinforced Flashing is a 60 -mil thermoplastic polyolefin (TP0)-based membrane available in 12" and 24" by 50' rolls. When the use of prefabricated accessories is not feasible, this product can be used to create inside and outside corners, field -fabricated pipe flashings, sealant pockets, and scuppers. Standard colors are white, tan, and gray. Features and Benefits • New and improved TPO Flashing provides 35% more flexibility, making it easier to field -fabricate details » Compounded with the same OctaGuard XT'" weathering package as Carlisle's Sure -Weld TPO membranes for maximum longevity » Superior weldability allows for consistent, high-quality seams in penetrations and other critical roof areas » Available in white, gray, and tan colors to match Carlisle's Sure -Weld TPO membranes Installation 1. TPO Flashing is used to flash various roofing system details and penetrations. The specific installation method will vary based on the situation. 2. Use a lower temperature setting on the heat welder than when welding reinforced TPO membrane. Typically, a setting of "6" on a scale of "10" is appropriate for welding TPO Flashing. HtmsS t :4RLISLi SYNTEC SYSTEMS 3. Use the edge of the roller to crease the flashing into any membrane step -offs for a proper seal. Review Carlisle specifications and details for complete installation information. Precautions » Review the applicable Safety Data Sheet for complete safety information prior to use. Sunglasses that filter out ultraviolet Tight are strongly recommended, as tan and white surfaces are highly reflective. Roofing technicians should dress appropriately and wear sunscreen. » Store TPO Flashing in a cool, shaded area and cover with light-colored, breathable, waterproof tarpaulins. TPO Flashing that has been exposed to the weather for approximately 7 days or longer must be prepared with Weathered Membrane Cleaner prior to hot air welding. Typical Properties and Characteristics Properties ASTM Test Method Specification Tolerance on nominal thickness, % D 412 plus 15/ minus 10 Weight, lb/ft2 (kg/m2), typical 0.30 (1.5) Tensile strength, min., psi (Mpa) 0 412 Die C 1200 (8.3) Elongation, ultimate, min., % D 412 Die C 600 Tear strength, min., Ibf/in (kN/m) D 624 Die C 250 (43.8) Ozone resistance, 168h @ 100 pphm, 50% ext. D 1149 No Cracks Heat aging: 28 days at 240°F (116°C) Tensile strength, min., psi (MPa) Elongation, ultimate, min., % Tear strength, min., Ibf/in (kN/m) Linear dimensional change, max. % D 573 D 412 D 412 D 624 D 1204 1000 (6.9) 500 200 (35.0) ±4 Resistance to Xenon -arc weathering Xenon -Arc, 10,080 kJ/m2 total radiant Exposure, visual condition at 10X G 155 0.70 W/m2 80°C B.P.T. No Cracks Typical properties and characteristics are based on samples tested and are not guaranteed for all samples o1 this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. LEED Information Pre -consumer Recycled Content 0% Post -consumer Recycled Content 0% Manufacturing Location Greenville, IL Solar Reflectance Index (SRI) N/A 800-479-6832 1 P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com Carlisle and OctaGuard XT are trademarks of Carlisle. Suro-Weld is a registered trademark of Carlisle. LEER is a registered trademark of the. U.S. Green Building Council. 10.06.15 C! 2015 Carlisle. REPRINT CODE 605089 - "Sure -Weld "IPO Non -Reinforced Flashing Product Data Sheat" EXPERIENCE THE CARLISLE DIFFERENCE I Sure-WeId° TPO Bonding Adhesive Overview Carlisle's Sure -Weld TPO Bonding Adhesive is a high-strength solvent - based contact adhesive that allows bonding of TPO membrane to various porous and non -porous substrates. Features and Benefits Solvent -based bonding adhesive that allows for quick drying A Can be roller -applied with medium nap roller A Provides excellent adhesion to various substrates Coverage Rate 60 ft2 (5.6 m2) per gallon finished surface. Coverage rates are average and may vary due to conditions on the jobsite. Porous surfaces and substrates may require more bonding adhesive than the typical coverage rate. Mixing Stir thoroughly until ail settled pigments are dispersed and the adhesive is uniform in color. Minimum 5 minutes stirring is recommended. Application 1. The surface, on or against which adhesive is to be applied, shall be clean, smooth, dry, free of fins, sharp edges, loose and foreign materials, oil and grease. Depressions greater than 1/4" (6 mm) should be feathered, using epoxy, mortar or other approved patching material. AM sharp projections shall be removed by sweeping, blowing or vacuum cleaning. liton 2. After thorough stirring (minimum 5 minutes), apply TPO Bonding Adhesive to substrate and membrane using a 9" (23 mm) medium nap roller. Application shall be continuous and uniform, avoiding globs or puddles. An open time of 5 to 50 minutes, based on drying conditions is recommended before assembly. TPO Bonding Adhesive must be allowed to dry until it does not string or stick to a dry finger touch. Any coated area which has been exposed to rain should be allowed to dry and then recoated. Do not apply adhesive to splice areas to be hot-air welded. 3. Roil the membrane onto the adhesive -coated substrate while avoiding wrinkles. Immediately brush down the bonded portion of the sheet with a soft -bristle push broom or a clean dry roller applicator to achieve maximum contact. Review current Carlisle specifications and details for specific application requirements. Precautions » Review the applicable Material Safety Data Sheet for complete safety information prior to use. A TPO Bonding Adhesive is EXTREMELY FLAMMABLE — it contains solvents that are dangerous fire and explosion hazards when exposed to heat, flame or sparks. Do not smoke while applying. Do not use in a confined or unventilated area. Vapors are heavier than air and may travel along ground or may be moved by ventilation and ignited by pilot lights, other flames, sparks, heaters, smoking, electrical motors, static discharge or other ignition sources at locations distant from material handling point and flashback. All containers should be grounded when material is transferred from one container to another. A red caution label is required when shipping. A fire extinguisher should be available. In case of fire, use water spray, foam, dry chemical or carbon dioxide. Do not use a solid stream of water because it can scatter and spread the fire. 3 Avoid breathing vapors. Keep container closed when not in use. Use with adequate ventilation. If inhaled, remove to fresh air. If not breathing, perform artificial respiration. If breathing is difficult, give oxygen. Call a physician immediately. During application, efforts must be made to prevent fumes from entering the building via air ventilation ducts. Do not place open containers or mix adhesive near fresh air intake units. When possible, shut down or seal off the closest units. b If swallowed, DO NOT INDUCE VOMITING. Call a physician immediately. n Avoid contact with eyes. Safety glasses or goggles are recommended. If splashed in eyes, immediately flush eyes with plenty of clean water for at least 15 minutes. Contact a physician immediately. 800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com EXPERIENCE THE CARLISLE DIFFERENCE ISure -Weld TPO Bonding Adhesive » Avoid contact with skin. Wash hands thoroughly after handling. In case of contact with skin, thoroughly wash affected area with soap and water. Contact physician if irritation persists. Note: Permeation -resistant gloves (that meet ANSI/ISEA 105-2005) are recommended to be wom when using this product to protect hands from irritating ingredients. Do not thin TPO Bonding Adhesive. Thinning will affect performance. Excessively thick or gelled material should be discarded. » Jobsite storage in excess of 90°F (32°C) may affect product shelf life. Should the TPO Bonding Adhesive be stored at temperatures lower than 60°F {15°C), restore to room temperature prior to use. Opened containers of TPO Bonding Adhesive should be used within 48 hours. Adhesives will begin to thicken after this point, making it difficult, and eventually impossible, to control applied thickness. In hot weather, do not leave sealed containers on roof for prolonged periods of time. In cold weather, keep material at room temperature until ready to use. Stir adhesive occasionally while using. Adhesive must be allowed to dry thoroughly. If membrane is mated with the substrate prior to the adhesive being dry, blistering will occur and not subside over time. » KEEP OUT OF THE REACH OF CHILDREN. 11111111111111111111111111111111111 CARLISLE SYNTEC SYSTEMS Typical Properties and Characteristics Base Synthetic rubber Color Yellow Solids 20% Flash Point -4°F (-20°C) closed cup Brookfield Viscosity 2600 centipoises Average Net Weight 7.1 lbs/gal (3.2 kg) Packaging 5 -gal pail Shelf Life 1 year Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. LEED Information Pre -consumer Recycled Content 0% Post -consumer Recycled Content 0% Manufacturing Location Carlisle, PA VOC Content 670 g/L 800-479-6832 1 P.O. Box 7000 I Carlisle, PA 17013 1 Fax: 717-245-7053 I www.carlislesyntec.com Carlisle and Sure -Weld are trademarks at Carlisle. LEED is a registered trademark of the U.S. Green Building Council, 01.13.14 ® 2014 Carlisle. REPRINT 000E:605925 -'Sure-Weld Bending Adhesive Product Data Sheet' EXPERIENCE THE CARLISLE DIFFERENCE (Sure -Weld TPO Cut -Edge Sealant Overview Carlisle's TPO Cut -Edge Sealant is a medium solids content, free-flowing, polymeric material designed to be used for sealing cut edges of Sure -Weld TPO Reinforced Membrane. It is available in clear for use with various colors of TPO membrane. Garlisle TPO Cut -Edge Sealant is used to seal cut edges of TPO Membrane, providing a waterproof barrier where scrim reinforcement is exposed. Features and Benefits » Provides excellent sealing of exposed fabric at cut membrane edges » Squeeze -bottle packaging allows easy, no -mess application » Available in clear for use with various colors of Sure -Weld TPO membrane kti ggig4 SYNTEC SYSTEMS Coverage Rate Approximately 225' — 275' (70 — 85 m) per 16 -oz. bottle when applied with '/s" (3 mm) bead. Approximately 115' —140' (35 — 45 mm) per 8 -oz. bottle when applied with 1/s" (3 mm) bead. » Application 1. All surfaces to be sealed with TPO Cut -Edge Sealant must be clean, dry and free from oil, grease, dirt and other foreign materials. 2. Apply a'/a" (3 mm) bead of TPO Cut -Edge Sealant from the plastic squeeze bottle to seal cut edges of reinforced TPO membrane. Do not apply TPO Cut -Edge Sealant on vertical surfaces. 3. Sealant should be tack -free in 2 hours and fully cured in 24 hours depending on weather conditions and application thickness. Review Carlisle specifications and details for complete installation information. Precautions 800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com EXPERIENCE THE CARLISLE DIFFERENCE ISure -Weld TPO Cut -Edge Sealant Review the applicable Material Safety Data Sheet for complete safety information. TPO Cut -Edge Sealant is FLAMMABLE — it contains solvents that are dangerous fire and explosion hazards when exposed to heat, flame or spark. Do not smoke while applying. Do not use in a confined area or unventilated area. Vapors are heavier than air and may travel along the ground to a distant ignition source and flashback. » Avoid breathing vapors. Keep container closed when not in use. Use with adequate ventilation. If inhaled, remove to fresh air. If not breathing, perform artificial respiration. If breathing is difficult, give oxygen. Call a physician immediately. » If swallowed, DO NOT INDUCE VOMITING. Cali a physician immediately. » Avoid contact with eyes. Safety glasses or goggles are recommended. If splashed in eyes, immediately flush eyes with plenty of water for at least 15 minutes. Contact a physician immediately. Avoid contact with skin. Permeation -resistant gloves (that meet ANSI/ ISEA 105-2005) recommended. Wash thoroughly after handling. In case of contact with skin, thoroughly wash affected area with soap and water. » Jobsite storage temperatures in excess of 90°F (32°C) may affect product shelf life. Should the TPO Cut -Edge Sealant be stored at temperatures below 60°F (15°C), restore to room temperature prior to use. » KEEP OUT OF THE REACH OF CHILDREN 02.14.14 ® 2014 Garllste, REPRINT CODE: 604821- Sure -Weld Cut -Edge Product Data Sheet' CARLISLE SYNTEC SYSTEMS Typical Properties and Characteristics Base Synthetic Rubber Color Clear Solids 14% Viscosity 3,500 cps Flash Point 39°F (4°C) Net Weight Gallon 7.4 Ibs (3.3 kg) Resistance to: Ozone Excellent UV Excellent Water Excellent Packaging Eight 16 -oz. bottles/carton (3.8 L) or two 8 -oz. bottles (1.9 L) Shelf Life 1 year Typical properties and cha acteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. LEED Information Pre -consumer Recycled Content 0% Post -consumer Recycled Content Manufacturing Location Rockland, MA VOC Content 750 g/L 800-479-6832 1 P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 1 www.carfistesyntec.com Carlisle and Sure -Weld are trademarks of Carlisle. LEED is a registered trademark of the U.S. Breen Building Council. EXPERIENCE THE CARLISLE DIFFERENCE I Sure-WeId TPO Coated Metal Overview Sure -Weld TPO Coated Metal is a 24 -gauge (0.6 mm) galvanized steel sheet that is coated with a layer of .035" non -reinforced TPO flashing. TPO membrane may be welded directly to the coated metal, eliminating the need to strip in the metal with a separate piece of TPO Pressure -Sensitive Coverstrip. The sheet is cut to the appropriate width and used to fabricate metal drip edges or other roof perimeter edging profiles. The metal is available in 4' by 10' (1.2 m by 3.1 m) sheets and comes packaged 10 or 25 sheets per pallet. Carlisle's TPO Coated Metal is part of Carlisle's comprehensive TPO accessory offering that meets the stringent quality tolerances required to be included in a Carlisle warranted roofing system. Features and Benefits Allows direct welding of TPO membrane to the metal, eliminating the need to strip in edging with additional TPO Pressure -Sensitive Coverstrip. » Easy to cut and form for creating a variety of edge sizes and profiles. Ran -4* SYNTEC SYSTEMS Installation 1. Install TPO Coated Metal with 1/13" to /4" (3-6 mm) between adjoining sections. 2. Install 2" -wide (5 cm) duct tape over joints in TPO Coated Metal. 3. Heat -weld 6" -wide (15.5 cm) piece of TPO non -reinforced flashing over joint. 4. Position TPO reinforced membrane and heat -weld to the TPO Coated Metal with a minimum 11/2" (4 cm) weld. Review Carlisle specifications and details for complete installation information. Precautions Store coated metal in a cool, shaded area and cover with light-colored, breathable, waterproof tarpaulins. TPO Coated Metal that has been exposed to the weather must be prepared with Weathered Membrane Cleaner prior to hot-air welding. Typical Properties and Characteristics Sheet Size 4' by 10' (1.2 m by 3.0 m) Weight 1.1 Ib/ft2 (5.4 kg/m1) Color Gray, Tan and White Flashing Thickness 0.035" (0.9 mm) nominal Steel Thickness 0.024" (0.6 mm) nominal (24 gauge) Steel Type Hot Dipped Galvanized Steel -- G90 Conforms to ASTM A653 Packaging 10 or 25 sheets per pallet Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. LEED Information Pre -consumer Recycled Content 09'0 Post -consumer Recycled Content 0% Manufacturing Location Franklin Park, IL Solar Reflectance Index (SRI) N/A 800-479-6832 I P.O. Box 7000 1 Carlisle. PA 17013 I Fax: 717-245-7053 I www.cartislesyntec.com Carlisle and Sure -Weld aro trademarks of Carlisle. LEED is a registered trademark of the U.S. Green Building Council. 02.26.16 C 2016 Carlisle.. REPRINT CODE: 604820 - "Sure -Weld TPO Coated Metal Product Data Sheet" EXPERIENCE THE CARLISLE DIFFERENCE Sure-WeId TPO Pipe Seals Overview Let Carlisle simplify your next Sure -Weld TPO installation with TPO Molded Pipe Seals. TPO Pipe Seals are injection -molded, pre -formed flashings for pipes 3/4" (19.0 mm) to 8" (203.2 mm) in diameter. TPO Pipe Seals are packaged in boxes of eight and come with universal stainless steel clamping rings. Carlisle's TPO Molded Pipe Seals are part of the Certified Fabricated Accessory (CFA) program. Certified Fabricated Accessories are the only factory -fabricated TPO accessories that meet the stringent quality tolerances required to be included in a Carlisle warranted roofing system, Features and Benefits » Provides a reliable method of waterproofing round pipe penetrations Provides a substantial labor savings compared to field fabricating from non -reinforced flashing » Provides more consistent appearance than field -fabricated pipe flashings » Double -ribbed cutting guide provides easier, smoother and straighter cuts » Rib design also keeps the clamp in the proper position for the life of the roofing system Productivity Boosting Features and Benefits: » Up to 60% labor savings compared to traditional field fabrication Quick and simple installation with no stretching required » Provides a consistent, finished appearance CARLISLE SYNTEG SYSTEMS Certified Fabricated Accessory Installation 1. Cut pipe seal between the two raised "ribs" to the desired diameter as illustrated on the flange of the pipe seal. (Do not cut off both raised "ribs".) 2. Pull TPO Pipe Seal over pipe until base flange is in contact with the membrane. (Application of heat to the top portion of the TPO Pipe Seal may be necessary to allow installation over the pipe.) 3. Mark pipe around the top of the TPO Pipe Seal. 4. Pull TPO Pipe Seal upwards on pipe until mark on the pipe is visible. 5. Install Water Cut-off Mastic below mark which indicates the top of the installed TPO Pipe Seal. 6. Pull TPO Pipe Seal back down over pipe and into position. 7. Heat weld the TPO Pipe Seal base flange to deck membrane (the hand -welder temperature setting should be between 5 and 6). 8. Install a stainless steel universal clamping ring to provide constant compression of the sealant. Review Carlisle specifications and details for complete installation information. Precautions » Remove all lead and other flashing. » Temperature of pipe must not exceed 160°F (71 °C). » When used with mechanically fastened membrane, install a minimum of four fastening plates around pipe penetrations. Position fastening plates around the penetration so the plates are covered by the pipe seal flange. A minimum 1W -wide weld must be maintained around the outer edge of the flange beyond the plates. If fastening plates cannot be installed in a manner to allow a minimum 11/2" weld, the plates must be placed outside the TPO Pipe Seal flange and covered with a reinforced TPO overlay. • Store pre -molded pipe seals in a cool, shaded area and cover with light- colored, breathable, waterproof tarpaulins. TPO Pipe Seals or membrane that has been exposed to the weather prior to use must be prepared with Weathered Membrane Cleaner prior to hot-air welding. 800-479-6832 1 P.O. Box 7000 I Garlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com EXPERIENCE THE CARLISLE DIFFERENCE ISure -Weld TPO Pipe Seals Typical Properties and Characteristics Sizes Packaging 3/" to 8" 0.0. pipe (19.0 to 203.2 mm) 8/box Weight (each) 0.63 lbs (0.3 kg) Material ; Injection -molded TPO Color f White, gray and tan Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. CARLISLE SYNTEC 01'6 TE LEED Information Pre -consumer Recycled Content i 0% Post -consumer Recycled Content ! 0% Manufacturing Location I Bloomingdale, IL Solar Reflectance Index (SRI) N/A Please use the chart below to cross-reference your pipe size with the proper step to cut as shown. Copper Tubing (C.T.S.) Nominal tube size i 3b" 1" vie Pipe 0.0. - T ' .881.13 1.38 Step of boot used 1 T~_ 1 1 Ph" 1.63 11 2" 2'h" 3" 4" 5" 6" 8" 2.13 2.63 3.13 4.13 2 2 3 4 5.13 6.13 N/A 6 N/A 5 Schedule 40 / 80 Steel Pipe - PVC Standard - Polyethylene Pipe IPS Nominal tube size 3/40 Pipe O.D. _ 1.05 Step of boot used 1 1" 1t/a" 1.32 1.66 1 1'/ 1'h" 1.90 1'h 2" 2.38 2 2t/z" 3" 4" 5" 6" 8" 2,88 3.50 4.50 5.56 6.63 8.63 3 3 4 5 6 8 Cast Iron Pipe Nominal tube size Pipe 0.0. Pit Class A & Spun 100-250 2" 3" 4" 6" 8" 2.50 3.96 Step of boot used 1 2 4 4.80 6.90 5 6 9.50 N/A 2" N/A N/A 3" Pit Class 8, C & D 4" 6" 5.00 7.10 4 5 6 3.96 8" 9.30 N/A Sewer - Soil Pipe PVC Plastic SDR 35 & 41 - Cast Iron Soil Pipe no hub - service weight & extra heavy Nominal tube size 4" 4" 4" 4" 6" _Pipe 0:0. 4.22 4.38 4.30 4.62 6.28 Step of boot used 4 4 4 4 6 6" 6" 6" 8" 8" 6.30 6.30 6.62 8.40 8.38 8.38 6 6 6 8 8 8 8" 8" 8.75 8 Conduit EMT Nominal tube size y4" 1" 1'/4" 1'k" 2" 21/2" 3" 31/2" Pipe 0.D. .922 1.16 1.51 1.74 2.19 2.88 3.50_ R 4.00 Step of boot used 1 1 1 11/2 2 �3 � �3 4 4" 4.50 4 Conduit IMC Nominal a/4 tube size " 1" 11/4" 1'/z" 2" 214" 3" 3' " _ Pipe 0.0. _ 1.02 1.29 1.63 1.88 2.36 2.85 3.47 3.97 Step of boot used 1 1 11/2 11/2 2 3 3 4 4" 4.46 4 Conduit Rigid Nominal tube size '/i" 1" 11/4" 11/2" 2" 23/2" 3" 31/2" 4" 5" Pipe 0.0. 1 1.05 1.32 1.66 1.90 2.37 2.87 3.5 4 4.5 Step of boot used 1 1 1 11/2 11/2 2 A 3 3 4 4 12,120.17 2014 Carlisle. REPRINT CODE: 604453 - "Sure -Weld TPD Pipe Seals Product Data Sheet" 5.56 5 800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com Carlisle and Sure -Weld are trademarks of Carlisle. t.EED is a registered trademark of the U.S. Green Building Council. EXPERIENCE THE CARLISLE DIFFERENCE I Sure-WeId TPO Inside Corners Overview Let Carlisle simplify your next Sure -Weld TPO installation with prefabricated Inside Corners. TPO Inside Corners are pre -molded and are used for flashing inside corners on a variety of details. Installation is fast and easy with no cutting or stretching required. Carlisle's TPO Inside Corners are part of the Certified Fabricated Accessory (CFA) program. Certified Fabricated Accessories are the only factory - fabricated TPO accessories that meet the stringent quality tolerances required to be included in a Carlisle warranted roofing system. Features and Benefits A Forms easily into "out -of -square" comers that are not exactly 90° A Provides substantial labor savings compared to field fabricating the flashing detail from non -reinforced flashing A More consistent appearance than inside corners field -fabricated from flashing 03.03.14 O 2014 Carlisle. REPAINT CODE: 602105 -'Inside Comers Product Data Sheet" SYNTEC SYSTEMS Certified Fabricated Accessory Installation 1. Position the TPO Inside Corner into the building corner, begin welding at the innermost corner point and work away from the corner. 2. Use a lower temperature setting on the heat welder than when welding reinforced TPO membrane. (Typically a setting of 6 on a scale of 10 is appropriate for welding TPO Inside Corners). 3. Use the edge of the roller to crease the corner flashing into any membrane step-off to create a proper seal. 4. Probe all welded edges of the corner only once the material has completely cooled to ensure watertight performance. Review Carlisle specifications and details for complete installation information. Precautions A Store TPO Inside Corners in a cool, shaded area and cover with light- colored, breathable, waterproof tarpaulins. TPO Inside Corners or TPO membrane that has been exposed to the weather prior to use must be prepared with Weathered Membrane Cleaner before hot air welding. Typical Properties and Characteristics Thickness 0.060" (1.5 mm) Packaging 12/bag Color White, Gray, Tan Material Injection molded Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. LEED Information Pre -consumer Recycled Content 0% Post -consumer Recycled Content 0% Manufacturing Location Bloomingdale, IL Solar Reflectance Index (SRI) N/A 800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com Carlisle and Sure -Weld are trademarks of Carlisle. LEED is a registered trademark of the U.S. Green Building Council.. EXPERIENCE THE CARLISLE DIFFERENCE I Sure-WeId TPO Outside Corners Overview Let Carlisle simplify your next Sure -Weld TPO installation with prefabricated Outside Corners. Sure -Weld TPO Outside Corners are pre - molded and are used for flashing outside comers on a variety of details. Installation is fast and easy with no cutting or stretching required. Carlisle's Sure -Weld TPO Outside Corners are part of the Certified Fabricated Accessory (CFA) program. Certified Fabricated Accessories are the only factory -fabricated TPO accessories that meet the stringent quality tolerances required to be included in a Carlisle warranted roofing system. Features and Benefits » Provide a substantial labor savings compared to field fabricating from non -reinforced flashing » Pre -stretched, multi -wave design allows wrapping outside comers that are out of square and not exactly 90 degrees » More consistent appearance than outside corners field fabricated from flashing Installation 1. Place the center point of the Sure -Weld TPO Outside Corner over the outside intersection of the corner. 2, Begin welding at the innermost center point and work away from the center by first welding the vertical portion of the flashing. 3. Use a lower temperature setting on the heat welder than when welding reinforced TPO membrane. (Typically a setting of 6 on a scale of 10 is appropriate for welding TPO Outside Corners). SYNTEC SYSTEMS Certified Fabricated Accessory 4. Use the edge of the roller to crease the corner flashing into any membrane step-off to create a proper seal. 5. Probe all welded edges of the corner only once the material has completely cooled to ensure watertight performance. Review Carlisle specifications and details for complete installation information. Precautions Store TPO Outside Corners in a cool, shaded area and cover with light- colored, breathable, waterproof tarpaulins. TPO Outside Corners or TPO membrane that has been exposed to the weather prior to use must be prepared with Weathered Membrane Cleaner before hot-air welding. Typical Properties and Characteristics Thickness 0.060" (1.5 mm) Packaging 12 per bag Color White, Gray, Tan Material Injection -molded TPO Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. LEED Information Pre -consumer Recycled Content 0% Post -consumer Recycled Content 0% Manufacturing Location Bloomingdale, IL Solar Reflectance Index (SRI) N/A 800-479-6832 1 P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec,com Carlisle and Sure -Weld are trademarks 51 Carlisle. LEEO is a registered trademark of the U.S. Green Building Council. 0920.13 Cr 2013 Carlisle. REPRINT CODE: 604459 - "Sure -Weld TPO Outside Comers Product Data Sheet' EXPERIENCE THE CARLISLE DIFFERENCE I Sure -Weld' TPO IT -Joint Covers Overview Let Carlisle simplify your next Sure -Weld TPO installation with molded T -Joint Covers. Sure -Weld TPO T -Joint Covers are used to seal step -offs at splice intersections. installation is mandatory on all 60- and 80 -mil TPO systems and on 45 -mil systems where step -offs have not been properly sealed. Sure -Weld TPO T -Joint Covers consist of 60 -mil non -reinforced TPO formed into a perfect 4.5" -diameter circle and packaged 100 parts per carton. Available in white, tan and gray. Carlisle's Sure -Weld TPO T -Joint Covers are part of the Certified Fabricated Accessory (CFA) program. Certified Fabricated Accessories are the only factory -fabricated TPO accessories that meet the stringent quality tolerances required to be included in a Carlisle warranted roofing system. Features and Benefits • Every T -Joint cover is a perfect 4.5" diameter circle • More consistent appearance than hand -cut flashing N Provides substantial labor savings compared to field -cut flashing m Seals channels at splice intersections created by seam step -offs 06.11.13 ® 2013 Carlisle. REPRINT CODE: 604458 - "Sure -Weld T -Joint Covers Product Data Sheet° CARLISLE Certified Fabricated Accessory Installation SYNTEC SYSTEMS 1. If membrane has been exposed to the weather, clean splice intersection area with Weathered Membrane Cleaner. 2. Use a lower temperature setting on the hand heat welder than that used for welding reinforced TPO membrane. (Typically a setting of "6" on a scale of "10" is appropriate for welding TPO T -Joint Covers.) 3. Center the T -Joint Cover over the splice intersection, begin welding at the center point and work towards the outside. Use the edge of the roller to crease the T -Joint cover into membrane step -offs to achieve a proper seal. 4. Using a probe, check all splices for voids and cold welds only once the T -Joint Cover has completely cooled. Make any needed repairs. Review Carlisle specifications and details for complete installation information. Precautions The TPO T -Joint Cover is not intended to overlay fasteners and plates as this requires the use of reinforced membrane. Store T -Joint Covers in a cool, shaded area and cover with light- colored, breathable, waterproof tarpaulins. T -Joint Covers that have been exposed to the weather must be prepared with Weathered Membrane Cleaner before hot-air welding. Typical Properties and Characteristics Size Thickness 4.5" (114 mm) 0.060" (1.5 mm) Packaging 100 per box Weight (per box) ! 3.5 lbs. (1.6 kg) Material I Non -Reinforced TPO Color White. Gray, Tan Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. 800-479-6832 1 P.O. Box 7000 I Carlisle, PA 17013 1 Fax: 717-245-7053 I www.cariislesyntec.com Carlisle and Sure -Weld are trademarks of Carlisle. EXPERIENCE THE CARLISLE DIFFERENCE SYNTEC SYSTEMS Weathered Membrane Cleaner Overview Let Carlisle simplify your next EPDM or TPO installation with Weathered Membrane Cleaner. Weathered Membrane Cleaner is used to clean both new and in-service Sure -Seal', Sure -White® and Sure -Tough® EPDM membranes and Sure -Weld's TPO membrane prior to the seaming process. It helps to loosen and remove dirt and other contaminants from the surface of the EPDM and TPO membranes and leaves a suitable surface for welding or the subsequent application of primer. Weathered Membrane Cleaner should be used when preparing EPDM membranes for application of primer, adhesives, SecurTAPE'", Factory -Applied Tape'" (FAT) and flashing. Do not use Weathered Membrane Cleaner on PVC membranes—instead use PVC Membrane Cleaner. Features and Benefits » Easily removes dirt and other contaminants from EPDM and TPO membranes » Prepares EPDM membrane for application of primer, adhesives and tape » Prepares aged or contaminated TPO membrane for welding Coverage Rate Coverage rate depends on the age of the membrane and the amount of dirt/debris on the surface. Assume 400 ft2 (37 m2) (one surface) per gallon. Application EPDM 1. Remove as much loose material as possible from the membrane surface where the adhesive or pressure -sensitive product will be applied by brooming or wiping the area with a dry rag. Extreme conditions of accumulated dirt may require a low sudsing detergent and water cleaning (rinse area thoroughly with CLEAN water and allow to dry). 2. Saturate a clean HP Splice Wipe (or equivalent) with Weathered Membrane Cleaner. SCRUB the area in a circular motion. Continue to clean the area, changing wipes frequently, until the surface is a consistent color with no streaking. Additional cleaning is required at factory seams (scrub parallel to the seam). Allow to dry. 3. Apply primer according to product instructions and/or roofing system specification. TPO Weathered Membrane Cleaner may be used to remove construction dirt or to prepare aged TPO membrane prior to welding. New TPO: 1. Saturate a clean HP Splice Wipe (or equivalent) with Weathered Membrane Cleaner. 2. Wipe the area to be cleaned until the membrane is a consistent color with no streaking and allow to dry. 3. Weld the cleaned material together with an appropriate hot-air welder. Welding Aged Material: 1. Using a Primer Pad and Weathered Membrane Cleaner, scrub the area to be welded. (The cleaner will become white with membrane residue during this step of the procedure.) 2. Clean all residue from the area to be welded with an HP Splice Wipe (or equivalent). Allow to dry. 3. Weld the cleaned material together with an appropriate hot-air welder. Review Carlisle specifications and details for complete application information. 800-479-6832 I P.O. Box 7000 1 Carlisle, PA 17013 I Fax: 717-245-7053 1 www.carlislesyntec.com EXPERIENCE THE CARLISLE DIFFERENCE Weathered Membrane Cleaner Precautions » Review the applicable Material Safety Data Sheet for complete safety information prior to use. » Weathered Membrane Cleaner is EXTREMELY FLAMMABLE. This product contains materials that are fire and explosion hazards when exposed to heat, flame or sparks. Store and use away from all sources of heat, flame or sparks. Do not smoke while applying. Do not use in a confined or unventilated area. Vapors are heavier than air and may travel along ground to a distant ignition source and flash back. A red caution label is required when shipping. » During application, efforts must be made to prevent fumes from entering the building via air ventilation ducts. Do not place open containers or mix adhesive near fresh -air intake units. When possible, shut down or seal off the closest units. » Avoid breathing vapors. Keep container closed when not in use. Use with adequate ventilation. If inhaled, remove to fresh air. If not breathing, perform artificial respiration. If breathing is difficult, give oxygen. Call a physician immediately. » If swallowed, DO NOT INDUCE VOMITING. Call a physician immediately. • Avoid contact with eyes. Safety glasses or goggles are recommended. If splashed in eyes, immediately flush eyes with plenty of water for at least 15 minutes. Contact a physician immediately. » Avoid contact with skin. Wash hands thoroughly after handling. In case of contact with skin, thoroughly wash affected area with soap and water. Note: Permeation -resistant gloves (that meet ANSI/ISEA 105-2005) are recommended to be worn when using this product to protect hands from irritating ingredients. » KEEP OUT OF THE REACH OF CHILDREN. SYNTEC SYSTEMS Typical Properties and Characteristics Color Solids Flash Point Boiling Point Clear 0% 65°F (18°C) 260°F (127°C Packaging 5-gailon (18.9 -liter) closed -top pail 2 x 1 -gallon (3.8 -liter) closed -top pail Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. LEED Information Pre -consumer Recycled Content 0% Post -consumer Recycled Content 0% Manufacturing Location Carlisle, PA VOC Content* 755 grams/liter 'This product is exempt from VOC regulations. 800-479-6832 I P.O. fax 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlisiesyntec.com 09.23.13 2073 Carlisle. Carlisle. Sure -Seal, Sure -Tough, Sure -While, Sure -Weld, SecurTape and Factory -Applied Tape (FAT) are trademarks of Carlisle. REPRINT CODE: 503626 - "Weathered Membrane Cleaner Product Bata Sheer LEED is a registered trademark of the U.S. Green Building Council. EXPERIENCE THE CARLISLE DIFFERENCE Water Cut -Off Mastic Overview Let Carlisle simplify your next membrane installation with its Water Cut -Off Mastic. Water Cut -Off Mastic is a one -component, low -viscosity, self - wetting, butyl -blend mastic designed to be used in conjunction with roofing and waterproofing systems. Itis primarily used as a sealing agent between various membranes and applicable when membrane is being terminated using a compression -type seal. Water Cut -Off Mastic is an extremely tacky material and will remain as such when used with compression -type terminations. SYNTEC SYSTEMS Application 1. All surfaces to be sealed with Water Cut -Off Mastic must be free of moisture, oil, dirt and other foreign materials. Water Cut -Off Mastic cannot be used on insulation. 2. Apply a'' /i" (13 mm) bead of Water Cut -Off Mastic between the substrate and the edge of the membrane. 3. Apply appropriate termination material and secure to provide constant compression for the Water Cut -Off Mastic. Review Carlisle specifications and details for complete application information. Precautions » Review the applicable Material Safety Data Sheet for complete safety information prior to use. » Water Cut -Off Mastic is FLAMMABLE — contains solvents that are dangerous fire and explosion hazards when exposed to heat, flame or sparks. Store and use away from all sources of heat, flame or sparks. Do not smoke while applying. Do not use in a confined or unventilated area. Vapors are heavier than air and may travel along ground to a distant ignition source and flash back. » Avoid breathing vapors. Keep container closed when not in use. Use with adequate ventilation, If inhaled, remove to fresh air. If not breathing, perform artificial respiration. If breathing is difficult, give oxygen. Call a physician immediately. If swallowed, DO NOT INDUCE VOMITING. Call a physician immediately. Avoid contact with eyes. Safety glasses or goggles are recommended. If splashed in eyes, immediately flush eyes with plenty of clean water for at least 15 minutes. Contact a physician immediately. Features and Benefits 3, Extremely tacky » Provides a durable compression -type seal between various membranes and parapet wall constructions Coverage Rate 10 linear feet per tube at the recommended application rate of a 1/2" bead. b Avoid contact with skin. Wash hands thoroughly after handling. In case of contact with skin, thoroughly wash affected area with soap and water. Note: Permeation -resistant gloves (that meet ANSI/ISEA 105-2005) are recommended to be worn when using this product to protect hands from irritating ingredients. 800-479-6832 1 P.O. Box 7000 1 Carlisle, PA 17013 I Fax: 717-245-7053 1 www.carlislesyntec.com EXPERIENCE THE CARLISLE DIFFERENCE Water Cut -Off Mastic Typical Properties and Characteristics Color Gray Solids 80% Flash Point 40 F (4 C) Closed Cup Service Temperature -40 F to 200 F (-40 C to 93 C) Specific Gravity 1.29 Cold Weather Flexibility Excellent Average Brookfield Viscosity 1,320,000 cps Packaging 25 tubes/carton Clean up Weathered Membrane Cleaner Average net weight/carton 28 lbs (13 kg) Shelf life 1 year, unopened container Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. LEED Information Pre -consumer Recycled Content 0% Post -consumer Recycled Content 0% Manufacturing Location Carlisle, PA VOC Content 250 g1L 11.21.13 0 2013 Cerlisle. REPRINT CODE: 603622 - "Water Cut -Off Mastic Product Data Sheet' SYNTEC YSTEA4S 800-479-6832 I P.O. Box 7000 1 Carlisle, PA 17013 1 Fax: 717-245-7053 1 www.carlislesyntec.com Carlisle and Sure -Seal are trademarks of Carlisle. LEED is a registered trademark of the U.S. Green Building Council. EXPERIENCE THE CARLISLE DIFFERENCE ISure -Weld` TPO Walkway Rolls 1 Overview Carlisle's Sure -Weld heat -weldable Walkway Roll is designed to protect the Sure -Weld TPO membrane in areas exposed to repetitive foot traffic and other hazards. Walkways must be installed at all traffic concentration points (i.e, roof hatches, access doors, rooftop ladders, etc.) regardless of traffic frequency. Walkways must also be installed if regular maintenance (once a month or more) is necessary to service rooftop equipment. Carlisle Sure -Weld Walkway Rolls are part of the Certified Fabricated Accessory (GFA) program. Certified Fabricated Accessories are the only factory -fabricated TPO accessories that meet the stringent quality tolerances required to be included in a Carlisle warranted roofing system. Features and Benefits Increased slip resistance created with a diamond plate tread pattern • Walkway edges are trimmed in safety yellow to better define the designated traffic flow » The yellow edges are smooth without tread Tugs for easier welding » Superior weathering package for long term performance Stocked in white, tan and gray, special colors available (minimum quantities apply) Installation 1. Use Weathered Membrane Cleaner to prepare the membrane to be welded to the walkway material. 2. Position the walkway material. Cut the Walkway Rolls into maximum 10' lengths and position with a minimum 1" gap between adjacent pieces to allow for water drainage. Cut the walkway so a 4" minimum gap is created over any field splices. Since the attachment of the walkway to the membrane is permanent, this will allow access to the field seams. 01.19.18 0 2018 Carlisle. REPRINT CODE: 600322- "TPO Walkway Rolls Product Data Sheet" .4evv� is • G4RLISLE SYNTEC SYSTEMS Certified Fabricated Accessory 3. Using an automated welder, weld all four sides of the walkway material to the membrane. Typically the same speed and temperature settings will be used for this procedure as for welding membrane to membrane. A test weld is always recommended prior to performing welds to the installed membrane. A hand held welder may be utilized, however, productivity will be decreased. Review Cadr`sle specifications and details for complete installation information. Precautions » Walkway Rolls are a maintenance item and are not covered under the Carlisle membrane systems warranty. » This product is to be used as a walkway only and is not designed as a perimeter warning line or a substitute for ballast. Walkway rolls cannot be installed within 10' (3m) of the roof perimeter. » Allow the walkway to relax and warm up in the sun prior to welding in place. » When possible, weld the walkway rolls when the ambient temperature is above 60°F (16° C) to help prevent wrinkles. Typical Properties Physical Property and Characteristics Test Method Typical Properties Minimum Maximum Dimensional Conformance Thickness, M. (mm) ASTM D412 0.160 (4.06) 0.180 (4.5) Density, lbs./ft3; (gr/cm';) ASTM D792 80.5 (1.29) 84.3 (1.35) Tensile Strength, psi (MPa) ASTM 0638 600 (4.1) Tear Strength, ibf/in (kN/m) ASTM D624 100 (17.5) Sizes 34" wide x 50' long Packaging 9 per skid, each roll individually bagged Weight (each) 97 lbs. Thickness 80 -mil at bottom of tread, 80 -mil at yellow welding edge, 170 -mil overall Color White, gray and tan Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and Information is Intended as a guide and does not reflect the specification range for any particular property of this product. LEED Information Pre -consumer Recycled Content 10% Post -consumer Recycled Content 0% Manufacturing Location Greenville, IL 800-479-6832 I P.O. Box 7000 I Carlisle, PA 17013 I Fax: 717-245-7053 I www.carlislesyntec.com cadtsle and Suro•Wele are trademarks of Gal -lisle. LEEO is a registered trademark of the U.S. Green Building Council. CARLISLE GOLDEN SEAL TOTAL ROOFING SYSTEM WARRANTY SERIAL NO. 10178056 971 BUILDING OWNER: SEGALE PROPERTIES NAME OF BUILDING: SEGALE RETAIL - #932 BUILDING ADDRESS: 300 ANDOVER PARK WEST, TUKWILA, WA DATE OF COMPLETION OF THE CARLISLE TOTAL ROOFING SYSTEM: 01/07/2019 DATE OF ACCEPTANCE BY CARLISLE: 03/28/2019 DATE OF ISSUE: March 28, 2019 oqoic CMD1252428 Carlisle Roiling Systems, Inc., (Carlisle) warrants to the Building Owner (Owner) of the above described building, that; subject to the terms, conditions, and limitations stated in this warranty, Carlisle will repair any leak in the Carlisle Golden Seafr"Total Roofing System (Carlisle Total Roofing System) installed by a Carlisle Authorized Roofing applicator for a period of 20 years commencing with the date of Carlisle's acceptance of the Carlisle Total Roofing System installation. However, in no event shall Carlisle's obligations extend beyond 20.5 years subsequent to the date of substantial completion of the Carlisle Total Roofing System. See below for exact date of warranty expiration. The Carlisle Total Roofing System is defined as the following Carlisle brand materials: Membrane, Flashings, Adhesives and Sealants, Insulation, Cover Boards, Fasteners, Fastener Plates, Fastening Bars, Insulation Adhesives, and any other Carlisle brand products utilized in this installation. TERMS, CONDITIONS, LIMITATIONS 1. Owner shall provide Carlisle with written notice via letter, fax or email within thirty (30) days of the discovery of any leak in the Cadisle Total Roofing System. Owner should send written notice of a leak to Carlisle's Warranty Services Department at the address set forth at the bottom of this warranty. By so notifying Carlisle, the Owner authorizes Carlisle or its designee to investigate the cause of the leak. Should the investigation reveal the cause of the leak to be outside the scope of this Warranty, investigation and repair costs for this service shall be paid by the Owner. 2. If, upon inspection, Carlisle determines that the leak is caused by a defect in the Carlisle Total Roofing System's materials, or workmanship of the Carlisle Authorized Roofing Applicator in installing the same, Owners remedies and Carlisle's liability shall be limited to Carlisle's repair of the leak. 3. This warranty shall not be applicable if, upon Carlisle's inspection, Carlisle determines that any of the following has occurred: (a) The Carlisle Total Roofing System is damaged by natural disasters, including, but not limited to, lightning, fire, insect infestations, earthquake, tornado, hail, hurricanes, and winds of (3 second) peak gust speeds of fifty-five mph or higher measured at 10 meters above ground; or (b) Loss of integrity of the building envelope and, or structure including, but not limited to partial or complete loss of roof deddng, wall siring, windows, doors or other envelope components or from roof damage by wind-blown objects, or: (c) The Carlisle Total Roofing System is damaged by any intentional or negligent acts, accidents, misuse, abuse, vandalism, civil disobedience, or the like. (d) Deterioration or failure of building components, including, but not limited to, the roof substrate, walls, mortar, HVAC units, non -Carlisle brand metal work, etc., occurs and causes a leak, or otherwise damages the Carlisle Total Roofing System; or (e) Adds, oils, harmful chemicals and the like come in contact with the Carlisle Total Roofing System and cause a leak, or otherwise damage the Carlisle Total Roofing System. (f) The Carlisle Total Roofing System encounters leaks or is otherwise damaged by condensation resulting from any condition within the building that may generate moisture. 4. This Warranty shall be null and void if any of the following shall occur. (a) If, after installation of the Carlisle Total Roofing System by a Carlisle Authorized Roofing Applicator there are any alterations or repairs made on or through the roof or objects such as, but not limited to, structures, fixtures, solar panels, wind turbines, roof gardens or utilities are placed upon or attached to the roof without first obtaining written authorization from Carlisle; or (b) Failure by the Owner to use reasonable care in maintaining the roof, said maintenance to include, but not be limited to, those items listed on Carlisle's Care 8 Maintenance Information sheet which accompanies this Warranty. - 5. Only Carlisle brand insulation products are covered by this warranty. Carlisle specifically disclaims liability, under any theory of law, for damages sustained by or caused by non -Carlisle brand insulation products. 6. During the term of this Warranty, Carlisle shall have free access to the roof during regular business hours. 7. Carlisle shall have no obligation under this Warranty while any bills for installation, supplies, service, and warranty charges have not been paid in full to the Carlisle Authddzed Roofing Applicator, Carlisle, or material suppliers. 8. Carlisle's failure at any time to enforce any of the terms or conditions stated herein shall not be construed to be a waiver of such provision. 9. Carlisle shall not be responsible for the cleaniness or discoloration of Carlisle Total Roofing System caused by environmental conditions including, but not limited to, dirt, pollutants or biological agents. 10. Carlisle shall have no liability under any theory of law for any claims, repairs, restoration, or other damages including, but not limited to, consequential or incidental damages relating, directly or indirectly, to the presence of any irritants, contaminants, vapors, fumes, molds, fungi, bacteria, spores, mycotoxins, or the like in the building or in the air, land, or water serving the building. 11. This warranty shall be transferable upon a change in ownership of the building when the owner has completed certain procedures including a transfer fee and an inspection of the Roofing System by a Carlisle representative. CARLISLE DOES NOT WARRANT PRODUCTS UTILIZED IN THIS INSTALLATION WHICH IT HAS NOT FURNISHED; AND SPECIFICALLY DISCLAIMS LIABILITY, UNDER ANY THEORY OF LAW, ARISING OUT OF THE INSTALLATION AND PERFORMANCE OF, OR DAMAGES SUSTAINED BY OR CAUSED BY, PRODUCTS NOT FURNISHED BY CARLISLE OR THE PRIOR EXISTING ROOFING MATERIAL OVER WHICH THE CARLISLE ROOFING SYSTEM HAS BEEN INSTALLED. THE REMEDIES STATED HEREIN ARE THE SOLE AND EXCLUSIVE REMEDIES FOR FAILURE OF THE CARLISLE TOTAL ROOFING SYSTEM OR ITS COMPONENTS. THERE ARE NO WARRANTIES EITHER EXPRESSED OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY, WHICH EXTEND BEYOND THE FACE HEREOF. CARLISLE SHALL NOT BE LIABLE FOR ANY INCIDENTAL, CONSEQUENTIAL OR OTHER DAMAGES INCLUDING, BUT NOT LIMITED TO, LOSS OF PROFITS OR DAMAGE TO THE BUILDING OR ITS CONTENTS UNDER ANY THEORY OF LAW. SEE ENCLOSED REFLECTIVITY ADDENDUM FOR FURTHER TERMS, CONDITIONS, AND LIMITATIONS. BY: Mark J. Long AUTHORIZED SIGNATURE TITLE: Director, Technical and Warranty Services This Warranty Expires: March 27, 2039 RECEIVED CITY OF TUKWILA MAY 162019 Ii I' P.O. Box 7000 Carlisle, PA 17013 Phone: 800.233.0551 Fax: 717,245.7121 www.carlistesyntec.com F0001 (3/18) r SERIAL NO. 10178056 971 NAME OF BUILDING: SEGALE RETAIL - #932 BUILDING ADDRESS: 300 ANDOVER PARK WEST, TUKWILA, WA DATE OF ISSUE: March 28, 2019 REFLECTIVITY PERFORMANCE AMENDMENT Subject to all of the warranty terms of the Carlisle System Warranty, Carlisle warrants that the Carlisle brand white Sure -Weld (TPO) membrane utilized in this installation will meet the "Energy Star" reflectivity rating of .65 when originally installed and a .50 reflectivity rating thereafter for a total period of ten (10) years from the date of installation. During this ten (10) year amendment period, the roof must positively drain and be free of pollutants, grease, oil, and the like. The owner must follow all membrane deaning recommendations made by Carlisle in the care and maintenance sheet, which accompanies this warranty. Any change in the use of this building, which adversely affects the deanliness of the membrane, will nullify this amendment. In order to make a daim under this warranty amendment, the Owner must thoroughly dean the membrane and send a representative sample to Carlisle. If, upon inspection by Carlisle, the membrane reveals a reflectivity rating below the warranted level, Carlisle will attempt to restore the membrane to its warranted reflectivity rating. Should Carlisle be unable to restore the warranted reflectivity rating, Carlisle's liability and Owner's remedy is limited to a credit to be applied towards the purchase of a new membrane; the value of that credit being determined by Carlisle based upon the number of remaining months of this warranty amendment used to pro -rate at the current price for the membrane. The maximum pro -rated value of the credit shall not exceed the original purchase price of the membrane. P.O. Box 7000 Carlisle, PA 17013 Phone: 800.233.0551 Fax: 717.245.7121 www.carlislesynlec.com WA -F0023 (05/13) 5/2/2019 City of Tukwila Department of Community Development CURTIS CAMPISTEGUY PO BOX 88028 TUKWILA, WA 98138 RE: Permit No. D18-0168 SEGALE PROPERTIES 300 ANDOVER PARK W Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 6/4/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 6/4/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sin erely, of K6ndace Nichols Permit Technician File No: D18-0168 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director December 2, 2018 Curtis Campisteguy PO Box 88028 Tukwila, WA 98138 RE: Request for Extension #1 Permit Number D18-0168 Dear Ms. Campisteguy, This letter is in response to your written request for reopening expired Permit D18-0168. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit through June 4, 2019. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, Pp)19 V Rachelle Ripley Permit Technician File: Permit No. D18-0168 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov SCEGALE PROPERTIES A LIMITED LIABILITY COMPANY COMMERCIAL INDUSTRIAL November 28, 2018 Bill Rambo Permit Technician City of Tukwila 6300 Southcenter Blvd #100 Tukwila, WA 98188 Re: Permit #D18-0168 Dear Bill, AGRICULTURAL NATURAL RESOURCES Please accept this letter as written request for a 180 -day extension for permit D18-0168. Due to inclement weather, the project has had to be postponed multiple times. We expect the project to be completed by the end of December. We appreciate your assistance in this matter. Please contact me with any questions. Sincerely, SEGALE PROP IES Curtis Campisteguy Request for Extension # Current Expiration Date: 41 I D Extension Request: W Approved for / f I days Denied (provide explanation) Signature "nitials __ RECEIVED CITY OF TUKWILA NOV 2 8 2018 PERMIT CENTER PO BOX 8 8 0 2 8 • TUKWILA, WA 9 8 1 3 8 • 5 8 1 1 SEGALE PARK DRIVE C • TUKWILA, WA 9 8 1 8 8 P 2 0 6. 5 7 5. 2 0 0 0 • F 2 0 6. 5 7 5. 1 8 3 7 • www.segaleproperties.com 11/1/2018 City of Tukwila Department of Community Development CURTIS CAMPISTEGUY PO BOX 88028 TUKWILA, WA 98138 RE: Permit No. D18-0168 SEGALE PROPERTIES 300 ANDOVER PARK W Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 12/4/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 12/4/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: D18-0168 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORS COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0168 DATE: 05/30/18 PROJECT NAME: SEGALE PROPERTIES SITE ADDRESS: 300 ANDOVER PARK W X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: L 5-31--c€ 1 Building Division Public Works n A11,4- 3H6 Fire Prevention Planning Division Structural nPermit Coordinator n PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 05/31/18 Structural Review Required REVIEWER'S INITIALS: DATE: El APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) DUE DATE: 06/28/18 Approved with Conditions 71 Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 SEGAI_; PROPERITIES LLC Home Espanol Contact Safety & Health Claims & Insurance C4iiWashington State Department of Labor & Industries Page 1 of 2 Search L&I A-7, Index Heip My L&I Workplace Rights Trade & Licensing SEGALE PROPERITIES LLC Owner or tradesperson Principals SEGALE, MARIO A, PARTNER/MEMBER SEGALE, MARIO A, AGENT Doing business as SEG))_E PROPERITIES LLC WA UBI No. 602 0^3 533 PO BOX 88028 TUKWILA, WA 98138-2028 206-575-2000 KING County Business type Limited Liability Company Governing persons LISA M ATKINS TINA A COVEY; DEVELOPMENT METRO LAND; TERESA NADEAU; NITA L SEGALE; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no, SEGALPL902CQ Effective — expiration 02/18:2010— 05/01/2020 Bond SAFFDO INS CO OF AM Bond account no. 6115'46 $12,000.00 Received by L&I Effective date 03/28.7002 02/18/2010 Expiration date Until Canceled Insurance Alaska National Insurance Co $1,000,000.00 Policy no. 18DLS31006 Received by L&I Effective date 03/30/2018 04/01/2018 Expiration date 04/01/2019 Insurance history Help us improve haps://s ;cure.lni.wa.gov/verify/Detail.aspx?UBI=602023533&LIC=SEGALPL902CQ&SAW= 6/1/2018 S:\Facilities\Retail Center\Building\Facilities\Drawings\Cad\Retail Center\932 ReRoof Permit.dwg, 5/29/2018 11:19:32 AM, Canon iPF780 30'-0" —f— 35'-0" —1 410'-3" ,f<5N^, 0 �ti 0' f-0. be PARCEL NO.: 262304 9001 ROOF AREA: 125,744 SQUARE FEET EXISTING ROOF SYSTEM: METAL DECKING R -I9 RIGID INSULATION JP STEVENS "HI -TUFF" SINGLE -PLY ROOF MEMBRANE ROOF ACCESS NEW ROOF SYSTEM: 60 MIL TPO SINGLE -PLY MEMBRANE MECHANICALLY ATTACHED OVER EXISTING ROOF SYSTEM. 4" DENS DECK INSTALLED WHERE SLOPE EXCEEDS i" PER 12". ROOF RATING: EXISTING CLASS "A" CLASSIFICATION TO BE MAINTAINED WITH NEW MEMBRANE INSTALLATION. 11C 7.5 TON 11B 12.5 TON 11A 12.5 TON 10C 7.5 TON 10B 12.5 TON 10A 12.5 TON SKYLIGHTS I®! 9C 7.5 TON 9B 12.5 TON 9A 12.5 TON 0 8C RAISE CURBS ON EXISTING HVAC 6C 7.5 TON UNITS WHERE REQUIRED 12.5 TON 8B 7B 6B 12.5 TON 12.5 TON 12.5 TON 8A 12.5 TON ROOF PLAN 470'-0" 7A 12.5 TON IA 6A 12.5 TON 79'-114 5B 7.5 TON 5A 7.5 TON VI El ROOF ACCESS 4B 7.5 TON 4A 12.5 TON FILE COPY Permit No. Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy : • d . re s is acknowledged: r'y By: Date: 6 City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the Scoop of wo.rI< without prior approval of Tzi!o.vila Building Division. ,sb, t°!OTE: R visions will require a new plan submittal and may include additional plan reviewfees, 12.5 TON " TE PERMIT illED FOR: h. I,4:achanical 1/1•Ctectrlcai firPtumbing Midas Piping City of Tukwila DUILDING DIVISION A05 SEGALE RETAIL CENTER VICINITY MAP NTS REVIEWED FOR CODE COMPLIANCE APP aOVLD JUN 012010 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 302018 PERMIT CENTER 168 PROPERTIES 300 Andover Park West PROJECT NUMBER: X 0' co co co^ .coOs to c0 a— D N n r- ! Q in co J ! O co � � X Q * LL * U O J uJ O Y � N ~ * a� m 0 111 CO J aj co < Z O LIJ O U)� CO W O W a_ 101. 1- DRAWING NUMBER: SHEET: f OF: 1 WWW.SEGALEPROPERTIES. COM c0 0 cV ] r i 0