Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D18-0187 - STONEWAY ROOFING - STORAGE RACKS
STONEWAY ROOFING 581 STRANDER BLVD 018-0187 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov 0223300010 581 STRANDER BLVD Project Name: STONEWAY ROOFING DEVELOPMENT PERMIT Permit Number: Issue Date: Permit Expires On: 018-0187 11/1/2018 4/30/2019 Owner: Name: WESTERN B NORTHWEST WA LLC Address: PO BOX 460169 C/O RYAN, HOUSTON, WA, 77056 Contact Person: Name: MATT PREVOST Phone: (425) 207-0058 Address: 500 SW 16 ST, RENTON, WA, 98057 Contractor: Name: MR RACKS LLC Phone: (425) 207-0058 Address: License No: Lender: Name: Address: 500 SW 16TH ST, RENTON, WA, 98055 MRRACRL924BN STONEWAY ROOFING 581 STRANDER BLVD , TUKWILA, WA, 98188 Expiration Date: 1/17/2020 DESCRIPTION OF WORK: DELIVER AND INSTALL (31) BAYS OF PALLET RACK PER SEISMIC CALCULATIONS AND STAMPED FLOOR PLAN. ANCHOR INSPECTYION INCLUDED. Project Valuation: $8,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $432.95 Occupancy per IBC: S-2 Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: 11-14 I 1— 1— I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit a ree to the conditions attached to this permit. Signature: � (,/26-- -C Date: ` ` / l (2/ 1 Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 20: Per the response to correction letter dated October 19, 2018, no class IV commodities will be stored in the racks. Products stored will be metal and glass. 11: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 8: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 9: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 10: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 12: Maintain fire extinguisher coverage throughout. 14: Clearance between ignition sources, such as light fixtures, heaters and flame -producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 15: Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one-hour fire proofing, (b) sidewall sprinkler at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 13-16.1.4) 16: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.3.1) 17: Flue spaces shall be provided in accordance with International Fire Code Table 3208.3. Required flue spaces shall be maintained. 13: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 18: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 19: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 4046 SI-EPDXY/EXP CONC CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, PVA 98188 http://www.TukwilaWA.gov Building Permit No. Project No. Date Application Accepted: Date Application Expires: (For Office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION I /�,� Q (, r King Co Assessor's Tax No.: (JG. 23 O—ol,10 Site Address: Set L5���� _ r(kit) 0. Suite Number: NI. A- Floor: Tenant Name: 6—r0 I�+� W� t7'C' 1 (O, 5 New Tenant: X. Yes ..No PROPERTY OWNER J" Name: tjas, 4tj $0 b.) ACLL._Address:551 p 11 4 t J I�Zip:C� 1f��) City:.—t1 y . 1l ` State: i Dr CONTACT PERSON — person receiving all project communication Name: r ' Ir fry f t, p4* �/� ' i t f�,-�''� C�� ''" t Address: /(04-v,. 6t - City: r Stater Zip:9 605' City:14 _ � �� State A- Zipi051 Phone:4 25. ,t`7_6OSCax: 1415 -_,N, -7,s61 j'I 1 ` N,7`'�c c, cd Email: A ln,. L_S i Com GENERAL CONTRACTOR INFORMATION Company Name: j ^ ^ 12.44a LL �'S) Address: O 1(1)44, 3+ City: r Stater Zip:9 605' Phone ZS 2 2✓ A Qs ax:1 f, 5 zo"')d 01 II Contr Reg No.:/G02 --79.0)) 4 Exp Date: 1 17 / q Tukwila Business License No.: 04,3 X019 6 cis" t4tp 'IA / 8 H:IApplications\Fomts-Applications On Line\2011 AppliicationsWermit Application Revised - 8-9-11.docx Revised: August 2011 bh ARCHITECT OF RECORD Company Name: c i ' nt}-i 1j t� }'f� /�, A 'T V Company Name: �" / 4._ Phone::2 3- 8S i "1,3(5' V Architect Name: Email: / Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Company Name: c i ' nt}-i 1j t� }'f� /�, A 'T V Engineer Name J��71 L V ,cOtvv 1 3 Address: 2( 1 2Z ( 7k6.4...k.. 5 C City: ( R _) ,1,- State{ _ ' /1 ZiZip:C) Q 0 W j �/ U Phone::2 3- 8S i "1,3(5' V 1 11/ /� ` Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: j ejc.h..peci `�neo q NJ 9 Address: S3 C '".�-1'� City L A State: LJsfi, Zip�i '31 Page 1 of 4 1 BUILDING PERMIT INFORMATIO1 206-431-3670 Valuation of Project (contractor's bid price): $ e l 0, O 0 Existing Building Valuation: $ /v Describe the scope of work (please provide detailed information): p v L v sC30 6\4,43 of lekti\x- SA)Sfe-01-1 utyJ 'id -do -€.-6 Will there be new rack storage?)7....Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) /04 *For an Accessory dwellin , provideythe following: Lot Area (sq ft): S V"D Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the princiQal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes Compact: Handicap: 3 4 - No If "yes", explain: FIRE PPR, OTECTION/HAZARDOUS MATERIALS: J6 Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other(specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ _ Yes ❑ . o If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 " paper includingeugntitletial SafetyData T`il�� ltee�ts. SEPTIC SYSTEM A h [' d ry\ D On-site Septic System For on-site septic system, provide 2 copies of a current septic design approved by King County Hell'? y Department. H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1stFlo 3� O�� BIDO 2 Floor S, 1 0 (c 3`d Floor 000 .� Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) /04 *For an Accessory dwellin , provideythe following: Lot Area (sq ft): S V"D Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the princiQal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes Compact: Handicap: 3 4 - No If "yes", explain: FIRE PPR, OTECTION/HAZARDOUS MATERIALS: J6 Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other(specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ _ Yes ❑ . o If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 " paper includingeugntitletial SafetyData T`il�� ltee�ts. SEPTIC SYSTEM A h [' d ry\ D On-site Septic System For on-site septic system, provide 2 copies of a current septic design approved by King County Hell'? y Department. H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER ORA ORIZED ENyT� � I �b i �' Signature: " I v y 1 ' • Date: ) Print Name: Vit {) (.QA? a3 ► 12-1 2.41/411- (—Day Telephone: LP 2..S. 2.-07 —60. Mailing Address: 5 b 0 i 6 4.44 1 w' �l W ' , 0 O57 City State Zip H:Wpplications\Fornts-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT PermitTRAK I QUANTITY PAID $432.95 D18-0187 Address: 581 STRANDER BLVD Apn: 0223300010 $432.95 DEVELOPMENT $420.35 PERMIT FEE R000.322.100.00.00 0.00 $252.03 PLAN CHECK FEE R000.345.830.00.00 0.00 $163.82 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $12.60 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R14758 R000.322.900.04.00 0.00 $12.60 $432.95 Date Paid: Wednesday, June 20, 2018 Paid By: MR RACKS Pay Method: CHECK 8148 Printed: Wednesday, June 20, 2018 2:20 PM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION b'e 0107 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: ,,r42‘)/17 -P R L Type of Inspection: s.=. � /L. Address: sed -2409\ LtIt--- 44-.A Date Called: Special Instructions: ___ i,3&"1- Zola, 9a0/097 Date Wanted: / 2-/7 -/ e, p.m. Requester: /Orr Phone No: -206 697 12-471/ pproved per applicable codes. Corrections required prior to approval. • M M ENTS: NTPC2o-u-e fit Date: l 7 IQ� REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 3-01 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:Type 1--Ctt\e Li ANA4 ------z:) ;VI—. of Inspection: -----Ak--c- [(— Address:) \ Suite #: ,e --'i,��,- Contact Person: Special Instructions: Pre -Fire: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: t,154-41.s([f— kAQ$1( d . i t --- 1" -)t -1.:b tt..e-A-- Arc...4-,f.,‘ I kt KA 0,-- 4/-( 1 Eic,k- -- Nt;YLt[_ 2,IA\ roc- - --- p,‘ 'a IAC k _ i -- t1 c c tLe c r N 0 - Q -Sc) — (' (-Q., - 21 k0. Stec t R. 0., c V.. c Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector..l 13 Date: %Z h Zl 6 Hrs.: /_ c $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Job Title gotigoAti too/a4-TUk0tU, A By I`✓r�`- Subted - % -0 5TEEL. SELEt rtti►6 go0Ceicc. F'7LC Date42ar Job No. /542? Checked IMAt.+ Sts s bCstca oP piacits coilrow Tb 114e IDS T$c See 1204 soI.Z gin Coo& r /5.5, 3 of ASCE 7 !o LJS,4G -nde: AS* M6fo11 V! .0 4if tar . 1.6 fAtiulfl rs ~ 77) The pV tic. . /2/W .xs5)/4 !.44s ! R rActtlrf AcoQ,6-ss fa sl La me sire cols . it* 4.o 772.09Amv. (P -'A cEo) D'/t . 1.17% 9,4 04,411 . & b.0 Lt sytr. (moot.) DIA, Vt. = 6,10 70 13 . 14) le o. 4'i* Pm" P -JL D 1.J is I -8- ,wAx.. Lo pell. pek p "RAO! .M,+ c. BE Sheet / of 3 Co) ,q,4ats iypE A, c, D, i F : 3 boa tis.. £k AAc `,j 706- A : 3000 411 C4)010-) iv" 6 ; 2,200 LAI sR use 1.0 L,J $erii9 Dti.ecrt063.9,.__. REVIEWED Fb COD4 ' Pe C Co AMICL �3 s = C2 f3) 1 2oSk 0 et • 4'Z-3 c US/A6 VT -v. D, I(vo(0. 3t 2.50 $abs Ads 1411,g9 551112 z 5,014 Aim) Glitei11 z 371104 OCT 31 2018' - it - UI DIVISI 1 -mo 04 "or tEAL alt 'ier 0. c 2.0t"-,57 't"' _ 21oz Y - 44 AA R. C,.ht.p. Pz D'15(5.0.74 $- S.44)) 4- OAS ;. 2,01k* 41 yz'4i 4- t orS4-1 taeD6E Ape140X, ('y ip C-ob ) prit, ea -5E. root t o r Sq$e: _ES eft- 1051 1�j71 q1.6.1../".L pL`Ci # ¢Qt'.1 ' VA = 4otohnz 312 t !1 y ha. s��31, � - 2 a,v/ a l ciwz ow 1.4 C.tP i ortu 4J Er 1u S4o3 1 Va. = 12.464 174-/44 VuAt1 n 19,410 o.7.-1 w 1.11 - o. < 604.144 ; ,44,4. JT 1.2.05 ' ' (L404; 7Y(1)e C) Ceti RECEIVED CITY OF TUK ILA I.zo JUN 20 201 1? 4* ettACe. r ECS2.1 - (UN' s� S4.47 a PERMIT CEN ER `1�1 -41147 Job -title Subject Sy 6774 Date /201E Checked Job No. /8Z R. Sheet - of iiA6. 4MC1 P 2.D8it 9.1( 1' z 1• SS t u 5S f /L Ila 11/4°A, )4.44 C- SECT oils : Act t P. Z,BO MMAl. rx - 40' " 4- (let-lr) 7,27 fa is Ave gt = 2.04' - gach vos P Pct'' stm #Sri : 040$4. eoagp. = 8. a!'� 044444 71045 C ) &se pc,driss Atte a4;2:. Vi via Ap F 4, z. cin t$i -- .0k < Allots 4 :, 0.7 A l / ae 1.7$0 S; Atm ptaAre .At X9.i2 x (Z.sf 24a .. o.;qt v O, 7S• ! s ,Z'7 Si: �. t r 0,251S- — 621 C ,6ci3,4C 7z via cvtic. 5toutS or;orm +~ 2500 1.404 A 4) vr s 4 C' ,.. 107 ps; 004-9+4 our /14) t.1 1'10 AdA Fi,/o7 x 4o.s/i2 tr 0.53' 14Y, 9. 531 z p(4)2/2 us/016 ,kur,41, ' /.5© As ..11.7. FIs. / , 4 A& s (24 f S..a ©, p1/4„ 7.cjSS F7': Apt Amara, p !1493 - DJ `? .i1?i4X. Pc ioW rn, f � 12. 114cies iy, c (.v,»iZet e e /070.34 2.50 /2 0.40/ cot. F a , D7Rk M /88 $ i ARk. t4 *MakWiW A //Ei y T r k. T el to L A0..5.%. a 41.1g f 3 - P e,.1 eto Ckfas ' S r17, L. etps • ks-L z Ja z . 3.74, 4.4.444 IL A. 1 vk 341 . AA i 40. 2 W 4 IrezTi 1A) ze Z4 -&d* /Geek► �---- co,tM'R-oC..,t l /tv l U rt. k 3 a 2441 fes' e, )-44/1- o-No is D(7 may., We, i8sR 4/ ,4M . 4 t.tai it j 610 104. 1/12 �, = 2,30 k" r. 9, -is 0120 6/2) 4- =so s 1400 / /3Cfn•+ A0-0 : •'7�t Owls)- WL/ia ia 10.0 k•.' <44c' AJ 12,4,3 ic-4 1 Job TIM Subject Sy 67"k Date 4 Checked 204 Job No. 1 Sheet 3 of 3 r C-01.1.Mt414 : CaLUM) 'era 3.3"o- t3 44 C zrrla,4S 1.yf. /24.J ties 1 46071-i r��,1.Lcco kat 771 A 3: /54-A, ) CO C-3 &I -L. ©tt.) bg+.467,. 70 8 -0" Co 4J S O L 7H At, o,Sti 0.1T5 44. kt,zkor :i cot -0000 44,81"-) iec; fQJ cu()( ?7 F I.13e 4 t x. I-24" ro z 3.34S" Coz Z, INA 0i34 ry% 1•r w f,, o, T ir .00239 v 4 s 12,04- IP3ir 19 g milx 5. 4- a . c - = 5.3S kool m,' ' 12,28 41.24 L" m;o7 4,4 !2, Ji -:.� 6.1 r 30 es'. lit v. 30, 54,k" % oey. 0.7s /MO a G'S4 D.4 + 0.4/ y 19.q! p k. T+emtgv. t>fn. A#frfc; l . ?A 4/51 15 V/V - Nk *4. ,. • Fireproofing Aggregates Shotcrete Concrete Masonry Asphalt Roofing P iling S teel S oils Wood November 13, 2018 File No. 18-819 Building Official City of Tukwila Building Department 6300 Southcenter Blvd. Tukwila, WA 98188 Project: Address: Permit: Stoneway Roofing 581 Strander Blvd. D18-0187 A.Q.R. TESTING LABORATORY, INC. CONSTRUCTION INSPECTION AND MATERIAL TESTING NATIONALLY ACCEPTED LABORATORY REVISED TO REFLECT CORRECT PERMIT NUMBER This is to advise you that special inspections are completed on the above referenced project. The following inspection was required and a copy of our inspection report is attached. 1. Proprietary anchor installation To the best of our knowledge all work inspected conformed to Tukwila Building Department approved plans, specifications, IBC and related codes and/or verbal or written instructions from the Engineer of Record. Sincerely, A.A.R. TESTING LABORATORY, INC. Ki,mber%,,4 vderxow Kimberle Anderson President CC: Mr. Racks -Carey Ferguson,Matt Prevost RECEIVED CITY OF TU KW I LA NOV 13 2018 PERMIT CENTER Tel: (425) 881-5812 Fax (425) 881-5441 • 7126 180th Ave. NE • P.O. Box 2523 • Redmond, WA 98073 Field Report A.A.R. Testing Laboratory, Inc. 7125 180th Ave.N.E., Park 180, Phone 425.881.5812 Fax 425.881. Report #: 77018 Suite C1ti1, Redmond, WA 98652 5441 Client: Mr. Racks 500 S.W. 16th St. Renton, WA 98057 Contact: Carey Ferguson/Matt Prevost Project Number: Permit #: Project Name: Address: City: 18-819 D18 0187 Stoneway Roofing 581 Strander Blvd. Tukwila Inspection Performed: Proprietary Anchors Date: 11/5/2018 Time: Temperature: Anchor bolts for pallet racks, (30) bays total per sheet 1. Verified installation of Simpson Strongbolt 2 anchors, 1/2" x 4 3/4" with 3 1/2" embedment, torqued to 60 ft. lbs. Note: (6) bays of type C call out for (4) anchors per base plate, engineer of record to clarify this. Otherwise all anchors installed per ESR 3037 and per plan. Received letter (on file) from B. Kattula, engineer of record accepting this condition. �iECE{V. r� :tTY OF TUKV.11...A NOV 1 3 2018 PERMIT CENTER Distribution: ❑d Distribute Client ❑ Distribute Contractor ❑ Distribute Engineer ❑ Distribute Owner Distribute Municipality ❑ Distribute Other ❑ Distribute Architect ❑ Distribute Other Inspector: Trow, Michael Reviewed by: Gebhardt, Diane All reports are considered confidential and are the property of the client and A.A.R. Testing Laboratory, Inc. Reproduction except in full without the written consent of A.A.R. Testing is strictly forbidden L nnwood 19020 Hwy 99 Lynnwood, WA 98036 206-632-7820 206-633-1306 Fax Redmond 9001 151st Ave. N.E. Redmond, WA 98052 425-861-0100 425-869-7159 Fax WA Toll Free 800-244.0561 Matt, R:afirgSUppiy This is what we will be stocking on our racks in Tukwila. Metal Roofing. Skylights that comprise of steel frame and glass. Coil Nails. Metal Vents. Metal Flashing Lead Flashing THANK YOU BEN OLSON STONEWAY ROOFING SUPPLY ASSISTANT MANAGER 581 STRANDER BLVD TUKWILA, WA 98188 OFFICE 253-395-3500 FAX 253-395-3480 tfltr 0i9; Kent 22051 68th Ave. S. Kent, WA 98032 253-395-3500 253-395-3480 Fax Tacoma 10801 A St S. — Suite 0 Tacoma, WA 98444 253-203-2122 253-203-2126 Fax Web Site stonewayroofing.com COF3REC IO,"`J LTR# RECEIVED CITY OF TUKWILA. OCT 1 9 2018 'ERMIT CENTER 11/1/2018 City of Tukwila Department of Community Development MATT PREVOST 500 SW 16 ST RENTON, WA 98057 RE: Permit Application No. D18-0187 STONEWAY ROOFING 581 STRANDER BLVD Dear MATT PREVOST, Allan Ekberg, Mayor Jack Pace, Director In reviewing our current application files, it appears that your permit applied for on 6/20/2018, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of UNDER REVIEW and is due to expire on 12/20/2018. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is complete for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that we do not receive your written request for extension or request is denied, your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely; Bill Rambo Permit Technician File No: D18-0187 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 July 03, 2018 City of Tukwila Department of Community Development MATT PREVOST 500 SW 16 ST RENTON, WA 98057 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D18-0187 STONEWAY ROOFING - 581 STRANDER BLVD Dear MATT PREVOST, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: FIRE DEPARTMENT: Al Metzler at 206-971-8718 if you have questions regarding these comments. • Per NFPA 13, 2016 edition; The maximum storage height for single row rack storage of Class IV commodities with a ceiling sprinkler density of .29/3000 is 12 ft. The submitted plans indicate a maximum storage height of 20 ft. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. Sincerely, Bill Rambo Permit Technician File No. D18-0187 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 q'ERMITCOORDCOPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0187 DATE: 10/19/18 PROJECT NAME: STONEWAY ROOFING SITE ADDRESS: 581 STRANDER BLVD Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: Building Division ❑ Public Works ❑ A-141 AwC 1O iS Fire Prevention Structural Planning Division nPermit Coordinator n PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 10/23/18 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required ❑ Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 11/20/18 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire D Ping 0 PW 0 Staff Initials: 12/18/2013 PERMIT COORD COPY Q PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0187 DATE: 06/20/18 PROJECT NAME: STONEWAY ROOFING SITE ADDRESS: 581 STRANDER BLVD X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: 4WC (0L -7-{e Building Division Public Works s At" Cot+12 Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 06/21/18 Structural Review Required REVIEWER'S INITIALS: DATE: 11111111 n APPROVALS OR CORRECTIONS: DUE DATE: 07/19/18 Approved Approved with Conditions ❑ Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ®I Ping ❑ PW ❑ Staff Initials: _e_ 12/18/2013 R City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: )0 f 1 6 Plan Check/Permit Number: V ( @ - ()I E2,--7 D Response to Incomplete Letter # Response to Correction Letter # 3(Jk-`-j '6g4:)l El Revision # after Permit is Issued I ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: 1e -(A) fao aF V1 &.) Project Address: 5 S l ei — u116 Contact Person: ✓ Tr �� Q� � p c -t— _ Phone Number: — (pc) ) 2 1 Summary of Revision:�a-- (ZQ)5 O J embr0J v4- 1 f 4 (- i'( ✓' pow, iraarei.k_ RECEIVED CITY OF wn_A. OCT 19 2C",3 PERMIT CES P k Sheet Number(s): "Cloud" or highlight all areas of revision including of revis' n Received at the City of Tukwila Permit Center by: &—Entered in TRAKiT on L 0 W:\Fermit Center \Templates\Forms\Revision Submittal Form doc Revised: August 2015 MR RACKS LLC Home Espanol Contact. Safety & Health Claims & Insurance Washington State Department of Labor & Industries Page 1 of 2 Search L&I A -Z Index Help My L&1 Workplace Rights Trades & Licensing MR RACKS LLC Owner or tradesperson Principals Ferguson, Carey Scott, PARTNER/MEMBER Ferguson, Julie Lynn, PARTNER/MEMBER Ferguson, Carey Scott, AGENT GONSER, BRETT, PARTNER/MEMBER (End: 04/30/2013) MCLENDON, ROBERT, PARTNER/MEMBER (End: 04/30/2013) Doing business as MR RACKS LLC WA UBI No. 602 779 014 500 SW 16TH ST RENTON, WA 98057 425-207-0058 KING County Business type Limited Liability Company Governing persons CAREY FERGUSON JULIE FERGUSON; License Verify the contractors active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. MRRACRL924BN Effective — expiration 01/03/2008— 01/17/2020 Bond AMERICAN CONTRACTORS INDEM CO Bond account no. 100031015 $12,000.00 Received by L&I Effective date 01/03/2008 12/20/2007 Expiration date Until Canceled Insurance Ohio Security Ins Co $1,000,000.00 Policy no. BKS 54574031 Received by L&I Effective date 05/06/2018 06/29/2017 Expiration date Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602779014&LIC=MRRACRL924BN&SAW= 11/1/2018 King County The Information Included on this map has been compiled by King County staff from a variety of sources and is subject to change without notice. King County makes no representat Ions or warrant les, express or implied, as to accuracy, completeness, timeliness, or rights to the use of such Information. This document Is not intended for use as a survey product. King County shall not be liable for any general, special, Indirect , Incidental, or consequential damages Including, but not limited to, lost revenues or lost profits resulting from the use or misuse of the Information contained on this map. Any sale of this map or information on this map is prohibited except by written permission of King County. Date: 6/19/2018 f REVISIONS No Chendes sham be made to the scope of work witho:. i prior approval of Tukwila Building Division .�+.�, q.., ` ��"�,�; ,� y;�v,7_,;;,ra Will require a new pian suUmittat and may include additional plan review fees. KING COUNTY PARCEL NUMBER : 022330-0010 LEGAL DESCRIPTION: ANDOVER INDUSTRIAL PARK #4 LESS UP RR OPER R/W Analysis and Design of Racks Conform to the 2105 IBC Sec 2209, The 2012 RMI Code & Sec 15.5.3 Of ASCE 7-10 FILE COPY Permit No. 1 r P Plan review approval is subject to errors and omissions. COSE T F WT RK. Approval of construction documents does not authorize the violation of any adopted coda or ordinance. Receipt of approved Field Co y d conditions is acknowledged: D E LIVER AND INSTALL (31) BAYS OF PALLET By: Date: RACK PER SEISMIC CALCULATIONS AND STAMPED FLOOR PLAN. SPECIAL ANCHOR INSPECTION INCLUDED. City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE .. APPROVED OCT 31 2018 AT of Tu la BUILDING DIVISION PERMIT E:; :-'IED FOR: L ' cchanical 2/Electrical Crumbing W' as Piping Cily of Tukwila SlP.r'1NG DIVISION RECEIVED CITY OF TU KWILA JUN 20 2018 PERMIT CENTER b18oI8? 6a 03 NC O� Q 52 a z dip 0.1L8:01 yy 4go.e.6N46Wtz wa ,:::. c, z i Co) 2- , c4 64 ilmel ; ......% Col to 024 Z.. 44 CO c3 Cn lig zPit w Cattl) c9 c.,el 6:) a ori E..� • L -4 r12 o � O o to 1/4 z 1 0. W O w v) 0 1W ®O 0 V) ftfl 1- DRAWN BY: MTP SCS 3/16" = 1' DATE: 6-19-2018 DRAWING NO: CHECKED BY: SHEET NO. 1 0P 2 SHEET a . • ' 4 4,4 4 .4 . 4 • 4 , 04. • 4. .• 4. di • .• 4 44, 4 . a • , • 4' . • 4 4. 4 • • • • • '4. 4 4 44 -04 -444. dlyti Iwo tom ',74ftkr„,17 "41 tsIt'7 200. NOTES: 1. ALL PALLET RACK POSITIONED TO LEAVE A 6" FLUE SPACE MINIMUM ON ALL SIDES WHEN LOADED. 2. SHELF SUPPORTS ARE WIRE DECK - NO SOLID SHELVES 3. WAREHOUSE AREA IS APPROXIMATELY 34,000 SQ. FT. • a ' 4, a a 4 4 4 . • • ' . ' a •4 ' 4.; 4.. .4 4 • . • , . 4 4 :. . 4. • ....1 . .. a 41 ' 4 4 - 41 • 4 .4 ' , .. 4 '.4 (2 '•4 .. A t' < 0 , .•. 0 •• 4 ' 4 .* • ‘1. , a 94. • ' . • .0 .4 4 ,t; 4 .: , A • 4 4 . [ . a . 4 • . • 4 • 41' 4 . .' . .0 :1 "1 •• 4 . • ' .1 4 4 • • ; 4 "1 4'.4. .4 4 , • 4 •• ..1 4 . • A 'if A .44 4 .. 4. 4,.4 4 . a 4 .A ..• ..< 4: . . .1. 4 ' 1 4 ' • 0 4 • a •• . • 4 ' • .'.. 4. a • 4. • . , 4 4 ',4 1 • 4 •.../ 4114 4 . . 41 . .44'44 .< , a 'a 4 • 4 . . .`i ' 4 4 • • : • A .. . '41 .. a • . • 4 • , 4 , < 4 . 4 • .4 • 4 • 4• .' 4 • < • '' ' 4 4 [ 0 • " • • . • •• • .. .44 . 4 • .d. • '411. • *1 A '*. 44 . 4 . .4 : ' • 4 .. • • • • 4 '4 . A 4 A 4 •• 4 ' 4 ' • 4 4 4 . . 4 ..• • .. 1. . . A •• ' • • 4'. 4 • ' <I . . 4 ..413.. . 4 4 . 4 • • 41 / • a 4 . < , . 4 . < 4.4 . • 4 * 4' A. .a . 4 4. .11 ' ei ' A .4 < 4 ,ti 4' . • ' 4 '4' . • 44 4 ... 4 . 41 . ... • . • , 41 4 .4 a • ' a 4 .• 4 . a . 4.. 4 • 4 4 ad 4, 4 , , 4. .• , • A. 4. • . " • A d, . . • . A •4' 4. 4 A 4: 4 . • Ad ' ; 4‹ 0 • 4 4 .14 4 '44 . , 4 • • : '41 • • . • . • .4 . 4 • 4. 4:7.'4 • • 4 4 4 • 4 ' 9 . , • a 4.: 1'' 4 A 4. 4 • ' zi A . 4 . . . .. I .. •• a .4 . 4 . • • a : 4 . a , • a. 4 ' A. • 4 , 4 44, • ' 4 4 4 • a • 4 Ai • 4 < • 4 4 : , • 4 • . • • itY • ' '4. 4' • ‹. 4 4 • . 44 • • • 4' . • 4* 41,1 • ; . • .• • • . . . • • • ;41 4. 44. . • 4 .4 • . ' 4. • . 4 a • 4 4 44, 4 • • 4 • • 0 , A' , • .4 . ,4,4 ' 4 • ,41 A . .4 4 • '44 • A 441 4 . 4 cf. .• • . • .4 0•4 L-173 LJ 48"X 1081 ® 48" X 1081 ® 48" X 108" v.r 0 1®36" X 99" ®36" X 99" ®36" X 99" }©36" X 99"1®36" X 99" 036" X 991036" X 99"( )(:) 44" X 1061© 44" X 106"©44"X 1;T64'r=' X 106" 7. r. 1 0 44" X 1201 0 44" X 1201 0 44" X 1201 0 44" X 1201 44" X 120 LJ 4.%* 1 7 REVIEWED FOR CODE COMPLIANCE APPROVED OCT 31 2018 City of Tukwila BUILDING DIVISION _jRECEIVED 14(Ru OF TUKWILA JUN 20 2018 PERMIT CENTER rrl **k 03 44. OM aw w gR OgNieg 00:00 oPmierAg2 40.00VEM g 6nca MEAnn DRAWN BY: MTP SCALE: 1/8" = r -o" DATE: 6-14-2018 DRAWING NO: CHECKED BY: SHEET NO. 1 072 SHEETS BEAM DETAIL RACK TYPE "A"-108" -- "G" 106" 11/2" 1 14GA11/4" 17- 6" o oo r # VRJ 0 \ BEAM DETAIL RACK TYPE "A"-108" -- "G" 106" 11/2" 1 14GA11/4" 17- 6" !I'3 0 0 Q # L 0 0 \ 16' BRACING CONNECTION DETAIL ANCHOR DETAIL Z' OR 3" ANCHORS RACK DETAILS SCALE: NTS SIDE 9' FRONT RACK TYPE "A" 8' 3' SIDE ASTM A572 0R50 BEAM DETAIL RACK TYPE "B" - 99" 375 R 0000 J CO c-) Z I 1/8" 2" TYP. AS NOTED 140A THK r-1/4" REF. 0 0 ❑ ❑ r '1 7/011 3" .531 SQUARE L -}„_Rl/8" COLUMN DETAIL COLUMN DETAIL RACK TYPE "D"- "E" - "F" RACK TYPE "B" - "G" 6" BEAM SECTION 14 (3a. THIO. ASTM A572 GR50 BEAM DETAIL RACK TYPE "C" -9'P" -144" .375 R Qooil/ dc0 14 GA 3" c cCD, cz 2" TYP. 1--1/8" AS TED 1/4" REF. .531 SQUARE 5/8" DIA. -1/8 2 HOLES-�- 1/2" THK1� L 1/2"i 4 1/4" 3/16" 12 3/4" 6 1/2"--1 3" 6" 3" 1 3/16" V1 1/2" BASE PLATE DETAIL RACK TYPE "A" FRONT RACK TYPE "B" CK ELEVATIONS SCALE: NTS 20' 8' A/3' -6"A/ 1 5/8" BRACKET ASSY: I ---AS YOTED.1 6" 1u 0 r 0 \ .375 R D D C oo c0 c0 2" TYP. AS NOTED -1/4" REF. 3" 1 -1/8" 11 OA THK. 1.0 ❑ ❑ ❑ .531 SQUARE 7/8" 3" COLUMN DETAIL RACK TYPE "A" 5/8" DIA. -12 1/2" 4 HOLES BASE PLATE DETAIL RACK TYPE "B" and "E" COL 3"x 1 8' 1 DOUG E /8" to 8' HIGH J- SIDE FRONT RACK TYPE "C" BASE PLATE DETAIL RACK TYPE "C" 12' SIDE 12' 1/8'1 2 3/4" /8 BEAM SECTION 14 GATHK ASTM A572 0850 BEAM DETAIL RACK TYPE "E" and "F" • 120" R1/8" --I F--314" TYR 5/8" DIA. 2 HOLES 3/8" THK. 1/2" ,t .375 R 00011oc�o oocdoC9 2" TYP. AS NOTED 3" 1 1/8" 1/8" 13 GA THK 7/8" 3" COLUMN DETAIL RACK TYPE "C" 3/16" P 1 1/2" BASE PLATE DETAIL RACK TYPE "D" and "F" 5/8" DIA. 2 HOLES H3' -8"H 12' FRONT RACK TYPE "D" SIDE 3/4" TYP. BASE PLATE DETAIL RACK TYPE "G" 10' FRONT RACK TYPE "E" STRUCTURAL NOTES: 1. RACKS ARE MANUFACTURED BY SPACERAK OF LODI, CA OR EQUAL 2. MINIMUM YIELD (Fy) AND ULTIMATE (Fu) STEEL STRENGTHS FOR SELECTIVE RACKS SHALL BE AS FOLLOWS (a) BEAMS AND COLUMNS Fy=50ksi Fu=65ksi. (b) BRACING STRUTS Fy=36ksi Fu=58ksi. (c) BASE PLATES FY=36ksi Fu=S8ksi. 3. MAXIMUM RACK LOAD PER LEVEL PER PAIR OF BEAMS SHALL BE: TYPE A -C -D -E -F=3,600 LBS. TYPE B = 3,000 LBS. TYPE G = 2,200 LBS. 4. CONCRETE SLAB IS GIVEN AS 5 1/2" THICK WITH fc'=2,500 psi. 5. ALLOWABLE SOIL BEARING PRESSURE IS GIVEN AS 1,500 psf FOR GRAVITY LOADS. 6. TIE -DOWN ANCHORS SHALL BE SIMPSON STRONG BOLT II WEDGE ANCHORS. TYPE A USE TWO (2) 1/2'00 X 4 3/4" ANCHORS WITH A 3 1/2" EMBEDMENT PER BASEPLATE. TYPE B - D- E - F USE TWO (2) 1/2"0 X 4 3/4" ANCHORS WITH A 3 1/2" EMBEDMENT PER BASEPLATE. TYPE C USE FOUR (4) 1/2"0 X 4 3/4" ANCHORS WITH A 3 1/2" EMBEDMENT PER BASEPLATE. TYPE G USE ONE (1) 1/2"0 X 4 3/4" ANCHORS WITH A 3 1/2" EMBEDMENT PER BASEPLATE. PERIODIC SPECIAL INSPECTION IS REQUIRED AND SHALL BE COMPLETED PER ICC ESR -3037. 7. POST LOAD SIGNS NOT LESS THAN 50 SQUARE INCHES IN AREA SPECIFYING THE DESIGN CAPACITY AT CONSPICUOUS LOCATIONS. 8. IF ANY DISCREPANCY OCCURS, CONTACT THE ENGINEER FOR CLARIFICATION. 9. ANALYSIS AND DESIGN OF RACK CONFORMS TO THE 2015 IBC SEC 2209, THE 2012 RMI CODE, AND SEC. 15.5.3 OF SEI/ASCE 7-10 USING THE ASD METHOD WHERE: V = 0.67 Cs Ip Ws AND Ip= 1.0 (RESTRICTED AREA - NO PUBLIC ALLOWED) Ss=1.445 Cs = 2.5 Ca /R AND Ca = 0.3853 FOR THE GIVEN ADDRESS AND SITE CLASS D S1 0.538 R = 4.0 TRANSVERSE (BRACED) DIR. R = 6.0 LONGITUDINAL (MOMENT) DIR. Fa 1.0 10. PROJECT HAS NO FIELD WELDING, ALL WELDING IS COMPLETED IN THE SHOP BY LICENSED WELDERS 11. THERE ARE NO SHOP DRAWINGS FOR THIS PROJECT. THIS DRAWING SHALL SERVE AS THE PROJECT SHOP DRAWINGS. FIRE PROTECTION NOTES: 1. DESIGN DENSITY OF SPRINKLER SYSTEM: .29 GPM OVER 3,000 SQUARE FEET. FOR STORAGE OF CLASS I - IV COMMODITIES TO A HEIGHT OF 22'6'. PER WSRB REPORT FILE # 46-2633D/NS. DATED: DEC. 1st 1993. 2. TEMPERATURE RATING OF SPRINKLER HEADS: 286 ° HEADS 3. TYPE OF PRODUCT: CLASS IV 3203.5 SHINGLES ASPHALT ON STANDARD WOOD PALLETS. 4. TOP OF STORED PRODUCT NOT TO EXCEED : 20' 0" 5. APPROXIMATE CEILING HEIGHT: 28'6" .... 26'8" TO TRUSSES EXITING NOTES: 1. EXTERIOR DOORS ARE 3' SWING TYPE WITH LOCKING KNOB WHICH REQUIRES NO SPECIAL KNOWLEDGE OR EFFORT TO OPEN. 2. EXTERIOR EXIT DOORS TO BE MARKED PER APPLICABLE CODE 12' Te2 SIDE r 10' REVIEWED FOR CODE COMPLIANCE APPROVED OCT' 31 2018 City of Tukwila BUILDING DIVISION FRONT RACK TYPE "F" 12' SIDE I 8'-10" FRONT o, t RACK TYPE "G" 18 0187 RECEIVED CITY OF TUKWILA JUN 20 2018 PERMIT CENTER cq D3 0 co oa 1zz a c4,44NLAR gl6N0h Mnra GIN gi 54) i"nz4o al-cr(4) - t-) � U cmc w, Z O rn (, 4-9 co a Z el CV CLkj tT O Q 114 00 O J 0 D D ® L V)r9F-t DRAWN BY: MTP SCALE: AS SHOWN DATE: 6-14-2018 DRAWING NO: CHECKED BY SHEET NO. 2 OF 2 SHFBTS