Loading...
HomeMy WebLinkAboutPermit D18-0201 - SEATTLE CHILDREN'S HOSPITAL - INTERIOR LANDLORD IMPROVEMENTThis record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. D18-0201 SEATTLE CHILDREN'S HOSPITAL 3355 S 120TH PL UNIT 121 THE ABOVE MENTIONED Page # DIGITAL Code RECORDS PERMIT FILE INCLUDES Exemption (DR) EXEMPTION LOG THE FOLLOWING REDACTED INFORMATION Rr1 Explanatory Description StatutelRule Personal Information — The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As such, individuals' social security numbers are redacted to protect those Social Security Numbers individuals' privacy pursuant to 5 U.S.C. sec. 5 U.S.C. sec. DR1 Generally — 5 U.S.C. sec. 552(a), and are also exempt from disclosure 552(a); RCW 552(a); RCW under section 42.56.070(1) of the Washington 42.56.070(1) 42.56.070(1) State Public Records Act, which exempts under the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit Personal Information — expiration dates, or bank or other financial RCW 29 DR2 Financial Information — RCW 42.56.230(4 5) account numbers, which are exempt from disclosure pursuant to RCW 42.56.230(5), except when disclosure is expressly required by or governed by other law. 42.56.230(5) (7a) Redactions contain information used to prove identity, age, residential address, social security number or other personal information Personal Information — required to apply for a driver's license or RCW DR3 Driver's License. — RCW identicard. 42.56.230 42.56.230 (7a & c) (7c) Any record pertaining to a vehicle license plate, driver's license, or identicard issued under (7a & c) RCW 46.08.066 that, alone or in combination with any other records, may reveal the identity of an individual. Redacted content contains a communication between client and attorney for the purpose of obtaining or providing legal advice exempt from RCW DR4 Attorney -Client Privilege — RCW 5.60.060(2)(a); RCW disclosure pursuant to RCW 5.60.060(2)(a), which protects attorney-client privileged 5.60.060(2)(a); RCW 42.56.070(1) communications, and RCW 42.56.070(1), which protects, under the PRA, information exempt or prohibited from disclosure under another statute. 42.56.070(1) SEATTLE CHILDREN'S HOSPITAL 3355 S 120 PL UNIT 121 D18-0201 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 1023049082 3355 S 120TH PL Unit121 DEVELOPMENT PERMIT Project Name: SEATTLE CHILDREN'S HOSPITAL Permit Number: D18-0201 Issue Date: 9/6/2018 Permit Expires On: 3/5/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: SABEY CORPORATION 12201 TUKWILA INTL BLVD 4TH FL , SEATTLE, WA, 98168 TOM SPADER 12201 TUKWILA INTERNATIONAL BLVD 4TH FLOOR, TUKWILA, WA, 98168-5121 SABEY CONSTRUCTION INC Phone: (206) 277-5271 Phone: (206) 281-4200 12201 TUKWILA INTL BLVD 4TH FLOOR, TUKWILA, WA, 98168-5121 SABEYCI033KM Expiration Date: 1/12/2019 SABEY CORPORATION 12201 TUKWILA INTL BLVD 4TH FL , SEATTLE, WA, 98168 DESCRIPTION OF WORK: INTERIOR LANDLORD IMPROVEMENT OF EXISTING SHELL SPACE (SUITE 121) IN BUILDING 5, INTEGATE EAST CAMPUS. THE WORK INCLUDES NON-BEARING WALLS AND ARCHITECTURAL FINISHES. MECHANICAL, ELECTICAL AND SPRINKLER WILL BE BIDDER DESIGNED. Project Valuation: $276,905.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: IA Electrical Service Provided by: TUKWILA Fees Collected: $5,314.90 Occupancy per IBC: B Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No Volumes: Cut: 0 Fill: 0 Number: 0 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: J.,c44 a J,ca',f,, Date: • /6/1Y This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 20: TO SCHEDULE ALL FIRE INSPECTIONS CALL 206-575-4407. 4: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 1: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 2: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 3: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 5: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1010.1.9) 6: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 7: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 8: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1010.1.9.1) 12: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 10: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 9: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 14: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 13: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 15: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 16: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.11 of the International Building Code. 17: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. 11: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 18: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 19: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 21: ***BUILDING PERMIT CONDITIONS*** 22: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 23: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 'J 0 24: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 25: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterally braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 26: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 27: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 28: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 29: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles shall be ventilated in accordance with the applicable provisions of the International Mechanical Code. 30: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 31: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 32: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 33: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING 0502 LATH/GYPSUM BOARD 0406 SUSPENDED CEILING CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. \.%) 1 S— a� 1 Project No. Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: King Co Assessor's Tax No.: 102304-9082 3355 South 120th Place, Tukwila, WA 98168 Suite Number: 121A Floor: 1 Tenant Name: Seattle Children's Hospital New Tenant: ❑ Yes 0 .. No PROPERTY OWNER Name: Tom Spader Name: International Gateway East LLC City: Tukwila State: WA Zip: 98168 Address: 12201 Tukwila Int'l Blvd Email: toms@sabey.com City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Tom Spader Address: 12201 Tukwila Int'l Blvd City: Tukwila State: WA Zip: 98168 Phone: (206) 281-8700 Fax: (206) 282-9951 Email: toms@sabey.com GENERAL CONTRACTOR INFORMATION Company Name: Sabey Construction Address: 12201 Tukwila Int'l Blvd City: Tukwila State: WA Zip: 98168 Phone: (206) 281-8700 Fax: (206) 282-9951 Contr Reg No.: SABEYCI033KM Exp Date: 12/31/2019 Tukwila Business License No.: BUS -0102122 H:Wpplications\Forms-Applications On Line \2011 Applications\Pennit Application Revised - 8-9-11.docx Revised: August 2011 bh ARCHITECT OF RECORD Name: Sabey Corporation Company Name: Sabey Architecure Company Name: n/a Architect Name: Kara Anderson Address: 12201 Tukwila Int'1 Blvd City: Tukwila State: WA Zip: 98168 Phone: (206) 281-8700 Fax: (206) 282-9951 Email: karaa@sabey State: ENGINEER OF RECORD Name: Sabey Corporation Address: 12201 Tukwila Int'l Blvd Company Name: n/a Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Sabey Corporation Address: 12201 Tukwila Int'l Blvd City: Tukwila State: WA Zip: 98168 Page 1 of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 276,905 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): INTERIOR LANDLORD IMPROVEMENT OF EXISTING SHELL SPACE (SUITE 121) IN BUILDING 5, INTERGATE.EAST CAMPUS. THE WORK INCLUDES NON-BEARING WALLS AND ARCHITECTURAL FINISHES. MECHANICAL, ELECTRICAL AND SPRINKLER WILL BE BIDDER DESIGNED. Will there be new rack storage? ❑ Yes m.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: • Sprinklers m Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable; combustible or hazardous materials in the building? ❑ Yes ill No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC e` Floor 188,298 2,737 IA B 2nd Floor 183,369 IA B 3rd Floor 183,369 IA B Floors thnr Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: • Sprinklers m Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable; combustible or hazardous materials in the building? ❑ Yes ill No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFORMATION — 206-433-0179 Scope of Work (please provide detailed information): n/a Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District 0 ...Tukwila ❑ ...Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate 0 .. Highline ❑ ...Valley View ❑ .. Renton ❑ ...Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: ❑ On-site Septic System — For on-site septic system. provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Infortnation Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way ❑ ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities 0 ...Frontage Improvements El ...Traffic Control 0 ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Geotechnical Report 0 .. Maintenance Agreement(s) ❑ ...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank El .. Curb Cut 0 .. Pavement Cut ❑ .. Looped Fire Line 0 .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size .. WO # ❑ ...Water Only Meter Size WO # ❑ ...Deduct Water Meter Size ❑ ...Sewer Main Extension Public ❑ Private 0 ❑ ...Water Main Extension Public 0 Private 0 FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) 0 ...Water 0 ...Sewer Monthly Service Billing to: Name: 0 ...Sewage Treatment Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip H:\Applications\Forms-Applications On Line \2011 Applications\permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.32 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN Signature: Print Name: OAUTHOR ZED AGENT: Anna Krasinskaya Mailing Address: 12201 Tukwila Int'1 Blvd H: Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Date: 411I11 Day Telephone: (206) 281-8700 Tukwila WA 98168 City State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $3,255.24 D18-0201 Address: 3355 5120TH PL Unit121 Apn: 1023049082 $3,255.24 DEVELOPMENT $3,101.42 PERMIT FEE R000.322.100.00.00 0.00 $3,076.42 WASHINGTON STATE SURCHARGE 13640.237.114 0.00 $25.00 TECHNOLOGY FEE $153.82 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R15340 R000.322.900.04.00 0.00 $153.82 $3,255.24 Date Paid: Thursday, September 06, 2018 Paid By: SABEY CONSTRUCTION INC Pay Method: CHECK 55862 Printed: Thursday, September 06, 2018 10:10 AM 1 of 1 CRSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $2,059.66 D18-0201 Address: Apn: $2,059.66 Credit Card Fee $59.99 Credit Card Fee R000.369.908.00.00 0.00 $59.99 DEVELOPMENT $1,999.67 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R14886 R000.345.830.00.00 0.00 $1,999.67 $2,059.66 Date Paid: Monday, July 09, 2018 Paid By: KARA ANDERSON Pay Method: CREDIT CARD 042116 Printed: Monday, July 09, 2018 1:41 PM 1 of 1 CR SYSTEMS Page 2 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 07/09/2018 01:40:49 PM CREDIT CARD SALE MASTERCARD CARD NUMBER: **********1105 K TRAN AMOUNT: $2,059.66 APPROVAL CD: 042116 RECORD #: 000 CLERK ID: Bill Thank you! Customer Copy https: //classic. convergepay. com/V irtualMerchant/transaction. do?dispatchMethod=printTran... 7/9/2018 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 ))► 8- 0ao1 JS Project: Sea:- . Ch', U,rf_ s Ty a of Inspec 'on: 1�� � � Address: 3355 S, t 20- ? L . Date Called:( pecial Instructions: S.,. Date Wanted: /o -T I ZO/ a.m� Requester: Phone No: Approved per applicable codes. L! Corrections required prior to approval. COMMENTS: Ape 3a7 I ip rim& - Inspector: Date` d/7//zv /e," REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPEC ON NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 4. Pro'ect: I)_ .e of Ins. •ction: Address: 3333- s. /W Date Called: J Special instructions: Date Wanted: l0— Zi- zo«' a.m` Requester: Phone No: ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: fire Inspector:KO (pg._ j Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit p t 8'-6201. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: Sea ��t ct ��S Ty e of Inspection: �% J 1w..4 * I 1 toy rlstdr�ss= . Date Call d: A.33S5 5 • l ten ; 1121fvs �� Date Wanted:1 . ` zo/r p.nn. `' •• Requester: T- -- Se4-BAY Phone No: /- 2 , -2S5-367 .1 ❑ Approved per applicable codes. Corrections required prior to approval. COMME t-f4411"4.S- sov`/ AkO41 /n /11791? Inspector: OCA Date: aeop_ayi REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Projectt(:� `` 1 t44 r (.7itioafe-AS Szpi Typ f Inspection: vtot i rt. �d ress:�� s,� L Date Called: Special Instructions: +e # /�' ��-'J1�. 1 - C'�LAr f7n Date Wanted: �7 A 9 - o- CAV a.m. p.m. Re uester 1 , 'Isj"3' Phone No: 7/ 0 Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: frvedgi Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 018-020( 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: sexm /4.J Type of Inspection: Errt•4i n�� Address: Z3ss s /zap PL Date Gsum cvs-rte Special Instructions: /✓ll f- /2) DatS Wanted: 9 -1D -7_0r a.m. p.m. Reque t /s, s v ) one No: /-266._2.65-- 3( 71 ® Approved per applicable codes.Corrections required prior to approval. COMMENTS: At /mss .// diet_,,arute_- v 8' o`cr 7f$I4ry, ,41L ,f6,4t-d" Aid,/ L.c4T - Date: -1 r, ZP/ „ ) REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100.. Call to schedule reinspection. 3 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 1-- S-- 16/ PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: - ---k------1.N.,11-Ce C (--- ( J,,,,,, , Type of Inspection: Address:Contact Suite #: 33cc S, 1?�/-1-` Pi_ Person: Special Instructions: Phone No.: > Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: ----- - ti f — ` P Cn n. ,yA4 (A j f t -- 4. ► Ocics4fS Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:` .44 C_3 Date: /0/,,'l/ G Hrs.: % , 0 / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 a INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /66 , PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: Type of Inspection: Address: Suite #: 3JSc , Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: C frt f Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:,44'v. 5 3 Date: 7/2 71/& Hrs.: 1 . 0 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /SC—s—a% rti PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: /%l /; Type of Inspection: R Address:f Suite #: gj �f I Contact Person: , �/j / t� An if V , - Special Instructions: 6eAf ba 0.avt/ Phone No.: Pre -Fire: illi 1,—, ;Approved per applicable codes. Corrections required prior to approval. COMMENTS: - Needs Shift Inspection: / '-`1 I Sprinklers: R F ke&Alarm: \ l j Hood & Duct: �MoAitor: ti; '/ / I i Pre -Fire: illi 1,—, -Permits: _ 7 I` Occupancy Type: /5 1 `A Inspector t,1 ?Z — Date:2.- 5-1/ ' Hrs.: v1 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City,o'f Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attu : ,Address: Company Name: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 SAB EY July 30, 2018 City of Tukwila Attn: Bill Rembo 6300 Southcenter Boulevard Suite #100 Tukwila, WA 98188 RE: Revision Letter #1 DEVELOPMENT Permit Application Number D18-0201 SEATTLE CHILDREN'S HOSPITAL — 3355 S 120 PL — SUITE #121 Dear Mr. Rambo, Below are responses to the corrections letter we received from your office in a letter dated July 20, 2018 for project No. D18-0201. Please note that all corrections to the Architecture sheets concerning this review are clouded and noted as Revision No. 1. The following response is provided concerning the Building Review. 1. The partition wall shown on sheet A-801 has been revised per the comments provided and included as part of the resubmittal. Please see detail #3 — Non -Rated Floor to Ceiling Partition. This concludes our responses to the comments provided. Please review and let us know if you need any additional information. Sincerely, Sabey Architecture Anna Krasinskaya, Assoc. AIA annak@sabey.com CORRECTION RECEIVED CITY OF TUKWILA JUL 31 2018 PERMIT CENTER 12201 Tukwila Int'I Blvd - 4 Floor, Seattle, WA 98168 T 206.281.8700 F 206.282.9951 W sabey.com Data Centers / Real Estate / Technology July 20, 2018 City of Tukwila Department of Community Development TOM SPADER 821 2ND AVE, STE 410 SEATTLE, WA 98101 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D18-0201 SEATTLE CHILDREN'S HOSPITAL - 3355 S 120 PL - SUITE 121 Dear TOM SPADER, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x17 to a preferably maximum size of 24x36; all sheets shall be the same size; larger sizes may be negotiable. "New revised" plan sheets shall be the same size sheets as those previously submitted.) "STAMP AND SIGNATURES" (If applicable) For Engineers: "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient (WAC 196-23-010 & 196-23-020). Architects: "date" only not required (WAC 308-12-081). (BUILDING REVIEW NOTES) 1. Partition walls shall not be tied to a suspended ceiling grid as shown on sheet A-801. All partitions greater than 6 feet in height shall be laterally braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. The connections shall be capable of resisting the seismic forces. The ceiling framing system must not be used to provide lateral support for walls or partitions. Show the wall detail with walls seismically braced independently from the ceiling grid system. (Standard Seismic Applications Guide - IBC Category D, E, F) Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Sincerely, Bill Rambo Permit Technician File No. D18-0201 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0201 DATE: 07/31/18 PROJECT NAME: SEATTLE CHILDREN'S HOSPITAL SITE ADDRESS: 3355 S 120 PL Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: AT AUC Building Division Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ 1 PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 08/02/18 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required n Denied (ie: Zoning Issues) Approved with Conditions (corrections entered in Reviews) DUE DATE: 08/30/18 n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping 0 PW ❑ Staff Initials: 12/18/2013 PERMIT CORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0201 DATE: 07/09/18 PROJECT NAME: SEATTLE CHILDREN'S HOSPITAL SITE ADDRESS: 3355 S 120 PL - SUITE 121 X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division ublic Work iit°—{ PRELIMINARY REVIEW: Not Applicable (no approval/review required) Avi ,8wc. Fire PreventionNI Structural lk \ Planning Division ❑ Permit Coordinator 1111 DATE: 07/10/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required ❑ Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 08/07/18 n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: —7-0)--0—(9 Departments issued corrections: Bldg [ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 0 Q City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: D18-0201 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: Seattle Children's Hospital Project Address: 3355 S 120 P1 Contact Person Mm cj�Q(An Summary of Revision: l bvNap,A V0106' Phone Number: MO RECEIVED CITY OF TUKWILA JUL 3 1 2018 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revisio Received at the City of Tukwila Permit Center by: 11 --Entered in TRAKiT on 7-31-1 C:\Users\bill-r\Desktop\Jtevision Submittal Form.doc Revised: August 2015 SABEY CONSTRUCTION INC (7) Home Fspahol Contact Safety & Health Oft Washington State Department of /Labor & Industries Claims & Insurance Search L&I A -Z index Help Page 1 of 2 My L&I Workplace Rights Trades & Licensing SABEY CONSTRUCTION INC Owner or tradesperson Principals SABEY, DAVID ARTHUR, PRESIDENT SEWELL, PATRICIA ANNE, SECRETARY POOLE, LAURENT D, SECRETARY (End: 01/19/2011) HARMON, JAMES N, TREASURER (End: 01/19/2011) Doing business as SABEY CONSTRUCTION INC WA UBI No. 601 532 164 12201 TUKWILA INT'L BLVD 4TH FLOOR SEATTLE, WA 98168-5121 206-281-4200 KING County Business type Corporation Governing persons SABEY CORPORATION DAVID A SABEY; JOHN D SABEY; PATRICIA SEWELL; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. SABEYCI033KM Effective — expiration 05/14/1997— 01/12/2019 Bond .............. HARTFORD FIRE INSURANCE CO Bond account no. 52BSBCQ3983 Received by L&I 12/20/2004 Insurance ..................... National Fire Ins of Hartford Policy no. 2094061165 Received by L&I Active. Meets current requirements. $12,000.00 Effective date 12/31/2004 Expiration date Until Canceled $1,000,000.00 Effective date Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601532164&LIC=SABEYCI033KM&SAW= 9/6/2018 SABEY CONSTRUCTION INC 03/20/2018 ( ~ 11/01/2016 Expiration date 11/01/2019 Insurance history Savings (in lieu of bond) $6,000.00 Received by L&I Effective date 04/21/1994 Release date Impaired date N/A N/A Savings account ID Lawsuits against the bond or savings ............... No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts .............. No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations .................... No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 331,221-02 Doing business as SABEY CONSTRUCTION Estimated workers reported Quarter 2 of Year 2018 "11 to 20 Workers" L&I account contact TO / JULIE SUR (360)902-4715 - Email: SURJ235@lni.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes ........ ............................ No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 07/02/2015 Inspection no. 317936768 Location 2200 M St. NE Quincy, WA 98848 No violations Page 2 of 2 rfn. Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601532164&LIC=SABEYCI033KM&SAW= 9/6/2018 1 2 3 REFERENCE SYMBOLS ABBREVIATIONS PROJECT DIRECTORY DRAWING INDEX BUILDING SECTION INDICATOR X A.XXXX WALL SECTION INDICATOR 1 ENLARGED DETAIL INDICATOR SECTION DETAIL INDICATOR XX EXTERIOR ELEVATION INDICATOR INTERIOR ELEVATION INDICATOR MATCH LINE SEE XXIA-XXX MATCH LINE INDICATOR DRAWING REVISION INDICATOR 0 EXISTING COLUMN GRIDLINE INDICATOR NEW COLUMN GRIDLINE INDICATOR DATUM INDICATOR OR WORK POINT EL XXX.XX SPOT ELEVATION INDICATOR EL. XXX -XX" ROOM NAME XXXX ROOM INDICATOR <E <X XXXXX > EQUIPMENT INDICATOR XXXXX > FIXTURE INDICATOR <F XXXXX > FURNITURE INDICATOR <G XXXXX > GRAPHIC/SIGNAGE INDICATOR MISCELLANEOUS INDICATORS (DOOR) OPENING INDICATOR (F FINISH INDICATOR WINDOW INDICATOR (XX' -XX" AFF CEILING HEIGHT INDICATOR XX XX XX WALL TYPE INDICATOR MATERIAL (PER FINISH LEGEND) FINISH (PER FINISH LEGEND) HEIGHT CEILING HEIGHT/MATERIAL/FINISH INDICATOR KEYNOTE EXISTING TO REMAIN (SHOWN SHADED) EXISTING TO BE DEMOLISHED (SHOWN DASHED) J NEW TYPE OF WORK L- J Q FE FEC LJ FIRE EXTINGUISHERS MOUNTED TO WALL WITH BRACKET IN WALL -MOUNTED CABINET NNW • 0111111111111•1, 11.1•11111.1110 PARTITIONS (NON -RATED PARTITION) (1 -HOUR RATED PARTITION) (2 -HOUR RATED PARTITION) (3 -HOUR RATED PARTITION) (4 -HOUR RATED PARTITION) SMOKE BARRIER SMOKE PARTITION RCP SYMBOLS 1 CEILING -MOUNTED 2'X2' FLUORESCENT LIGHT CEILING -MOUNTED 2'X4' FLUORESCENT LIGHT CEILING -MOUNTED 1'X4' FLUORESCENT LIGHT (HIDDEN) CEILING -MOUNTED STRIP FLUORESCENT LIGHT (EXPOSED) CEILING -MOUNTED STRIP FLUORESCENT LIGHT WALL -MOUNTED 1 T 1 STRIP FLUORESCENT LIGHT 0 O 0> 5 0 6 DOWNLIGHT ACCENT DOWNLIGHT WALL -WASHER DOWNLIGHT SCONCE -TYPE (WALL -MOUNTED) LIGHT CEILING -MOUNTED EXIT LIGHT WALL -MOUNTED EXIT LIGHT STANDARD LIGHT FIXTURES Fo HVAC DIFFUSERS (SIZE AND TYPE PER MECHANICAL DRAWINGS) HVAC RETURNS/EXHAUSTS (SIZE AND TYPE PER MECHANICAL DRAWINGS) CEILING -MOUNTED HVAC ITEMS CEILING -MOUNTED ACCESS PANEL CEILING -MOUNTED FIRE SPRINKLER CEILING -MOUNTED SPEAKER ADDITIONAL ABBREVIATIONS ARE DEFINED IN LEGENDS THROUGHIOUT THE DRAWING SET. AC ASPHALTIC CONCRETE ACC ACCESSIBLE ACP ACOUSTICAL CEILING PANEL ACST ACOUSTICAL AD AREA DRAIN ADDM ADDENDUM ADJ ADJUSTABLE AFF ABOVE FINISHED FLOOR AHU AIR HANDLING UNIT ALT ALTERNATE ALUM ALUMINUM ANOD ANODIZED APPROX APPROXIMATE APT APARTMENT ARCH ARCHITECT, ARCHITECTURAL AUTO AUTOMATIC AV AUDIO VISUAL AWP ACOUSTICAL WALL PANEL(S) BB BD BLDG BLKG BO BOT BRG BRZ BSMT BUR CAB CB CEM CER CG CH CI CJ CIP CL CLG CLO CLR CMU CO COL COMM CONC CONN CONSTR CONT CORR CPT CSWK CTR CU D DBL DEMO DET DF DIA DIAG DIM DIV DMPF DN DR DS DW DWG DWR E EIFS EJ EL ELEC ELEV ENCL EP EQ EQUIP ESCAL EXH EXP EXIST FA FCIO FD FDC FDTN FE FEC FH FHC FIG FIN FLEX FLR FLUOR FO FOIC FP FR FRMG FRT FT FTG FUT FVC FWC FWP GA GALV GEN GFRC GFRG GFRP GL GYP GYP BD H HB HCWD HD HDBD HDW HDWD HM HO HORIZ HR HT HVAC BULLETIN BOARD BOARD BUILDING BLOCKING BOTTOM OF BOTTOM BEARING BRONZE BASEMENT BUILT UP ROOFING CABINET CATCH BASIN CEMENT, CEMENTITIOUS CERAMIC CORNER GUARD COAT HOOK CAST IRON CONTROL JOINT CAST -IN-PLACE CENTERLINE CEILING CLOSET CLEAR CONCRETE MASONRY UNIT CLEAN OUT, CASED OPENING COLUMN COMMUNICATION CONCRETE CONNECTION, CONNECT CONSTRUCTION CONTINUOUS, CONTINUE CORRIDOR CARPET CASEWORK CENTER CUBIC DEEP, DEPTH DOUBLE DEMOLISH, DEMOLITION DETAIL DRINKING FOUNTAIN DIAMETER DIAGONAL, DIAGRAM DIMENSION DIVIDE, DIVISION DAMPPROOF, DAMPPROOFING DOWN DOOR, DRESSING ROOM DOWNSPOUT DISHWASHER DRAWING DRAWER EAST EX 1 ERIOR INSULATION AND FINISH SYSTEM EXPANSION JOINT ELEVATION ELECTRIC, ELECTRICAL ELEVATOR ENCLOSE, ENCLOSURE ELECTRIC PANEL EQUAL EQUIPMENT ESCALATOR EXHAUST EXPANSION, EXPOSED EXISTING FIRE ALARM FURNISHED BY CONTRACTOR/ INSTALLED BY OWNER FLOOR DRAIN FIRE DEPARTMENT CONNECTION FOUNDATION FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FIRE HYDRANT FIRE HOSE CABINET FIGURE FINISH, FINISHED FLEXIBLE FLOOR, FLOORING FLUORESCENT FACE OF, FINISHED OPENING FURNISHED BY OWNER/ INSTALLED BY CONTRACTOR FIRE PROTECTION, FIREPROOF FRAME, FIRE RATED FRAMING FIRE RETARDANT TREATED FOOT, FEET FOOTING FUTURE FIRE HOSE VALVE CABINET FABRIC WALL COVERING FABRIC WRAPPED PANEL(S) GAGE GALVANIZED GENERAL, GENERATOR GLASS -FIBER REINFORCED CONCRETE GLASS -FIBER REINFORCED GYPSUM GLASS -FIBER REINFORCED PLASTIC GLASS GYPSUM GYPSUM BOARD HIGH HOSE BIBB HOLLOW CORE WOOD HAND DRYER HARDBOARD HARDWARE HARDWOOD HOLLOW METAL HOLD OPEN HORIZONTAL HOUR HEIGHT HEATING, VENTILATING, AND AIR CONDITIONING ID INCL INFO INSUL INT IWD JAN JT KIT L LAM LAU LAV LT LTG MAS MATL MAX MECH MED MEMB MEZZ MGT. MFL MFR MH MIN. MISC MO MS MTD MTL MVBL N, NIC NO NOM NTS OC 011 OD OPNG OPP ORD OTS PBD PRCST PD PERP PLAM PLAS PLYWD PNL PL PR PRKG PROP PT PTN R RCP RD REF REF REINF REQD REV RFG RM RO RT S SCWD SCHED SD SECT SG SGL SHT SHTHG SIM SPEC SPKLR SPKR SQ SS SST STC STD STL STOR STRUCT SUSP T T&G TEL TEMP TER THK TO TSTAT TV TYP. UIC UGND UNFIN UON VERT VEST VNR VR VWC W W/ WIO WC WD WH WP WR WT WWF XFMR INSIDE DIAMETER INCLUDE, INCLUDING INFORMATION INSULATE, INSULATION INTERIOR INDIRECT WASTE DRAIN JANITOR JOINT KITCHEN LONG LAMINATE, LAMINATED LAUNDRY LAVATORY LIGHT LIGHTING MASONRY MATERIAL MAXIMUM MECHANICAL MEDIUM MEMBRANE MEZZANINE MANAGEMENT MAXIMUM FORESEEABLE LOSS MANUFACTURE, MANUFACTURE MANHOLE MINIMUM, MINUTE MISCELLANEOUS MASONRY OPENING MOP SINK MOUNTED METAL MOVABLE NORTH NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE ON CENTER OVERHEAD OUTSIDE DIAMETER OPENING OPPOSITE OVERFLOW ROOF DRAIN OPEN TO STRUCTURE ABOVE PARTICLEBOARD PRECAST PLANTER DRAIN PERPENDICULAR PLASTIC LAMINATE PLASTER PLYWOOD PANEL PROPERTY LINE PAIR PARKING PROPERTY PAINT, POINT, PRESSURE TREATED PARTITION RADIUS, RISER REFLECTED CEILING PLAN ROOF DRAIN, ROAD REFER TO, REFERENCE REFRIGERATOR REINFORCED, REINFORCING REQUIRED REVISED, REVISION ROOFING ROOM ROUGH OPENING RIGHT SOUTH, SPANDREL SOLID CORE WOOD SCHEDULE STORM DRAIN SECTION SAFETY GLASS SINGLE SHEET SHEATHING SIMILAR. SPECIFICATION SPRINKLER SPEAKER SQUARE SERVICE SINK STAINLESS STEEL SOUND TRANSMISSION CLASS STANDARD STEEL STORAGE STRUCTURAL SUSPENDED TREAD, TEMPERED TONGUE AND GROOVE TELEPHONE TEMPERATURE, TEMPORARY TERRAllO THICK, THICKNESS TOP OF THERMOSTAT TELEVISION TYPICAL UNDER COUNTER UNDERGROUND UNFINISHED UNLESS OTHERWISE NOTED VERTICAL VESTIBULE VENEER VAPOR RETARDER VINYL WALLCOVERING WEST, WIDE WITH WITHOUT WATER CLOSET, WALLCOVERING WOOD WALL HYDRANT WEATHERPROOF, WATERPROOF, WATERPROOFING, WORK POINT WATER RESISTANT WEIGHT WELDED WIRE FABRIC TRANSFORMER ARCHITECT / DESIGNER: SABEYARCHITECTURE 12201 TUKWILA INT'L BLVD, FOURTH FLOOR SEATTLE, WA 98168 TEL: (206) 281-8700 FAX: (206) 282-9951 ATTN: TOM SPADER EMAIL: TOMS@SABEY.COM BUILDING OWNER: INTERNATIONAL GATEWAY EAST LLC 12201 TUKWILA INTL BLVD, FOURTH FLOOR SEATTLE, WA 98168 TEL: (206) 281-8700. FAX: (206) 282-9951 CONTACT: DEBBIESABEY.COM EMAIL: DEBBIES@SABEY.COM GENERAL CONTRACTOR: SABEY CONSTRUCTION 12201 TUKWILA INT'L BLVD, FOURTH FLOOR SEATTLE, WA 98168 TEL: (206) 281-8700 FAX: (206) 282-9951 CONTACT: JOSH JOHNSON EMAIL: JOSHJ@SABEY.COM PLUMBING ENGINEER: TBD - Design Build by G.C. MECHANICAL ENGINEER: TBD - Design Build by G.C. ELECTRICAL ENGINEER: TBD - Design Build by G.C. FIRE / LIFE SAFETY ENGINEER: TBD.- Design Build by G.C. PLUMBING, MECHANICAL, ELECTRICAL, LIFE SAFETY PERMITS UNDER SEPARATE SUBMITTALS. A-001 A-002 A-003 A-005 A-101 A-102 A-103 A-104 A-601 A-801 COVER SHEET AND PROJECT INFORMATION NOTES AND SPECIFICATIONS SITE PLAN LIFE SAFETY PLAN CONSTRUCTION PLAN REFLECTED CEILING PLAN POWER AND DATA PLAN. FURNITURE PLAN DOOR, DEVICE MOUNTING SCHEDULE AND DETAILS PARTITION TYPES BUILDING ADDRESS VICINITY MAP INTERGATE.EAST, BUILDING 5 3355 S. 120TH PLACE TUKWILA, WA 98168 SCOPE OF WORK INTERIOR LANDLORD IMPROVEMENT OF EXISTING SHELL SPACE (SUITE 121) IN BUILDING 5, INTERGATE.EAST CAMPUS. THE WORK INCLUDES NON-BEARING WALLS AND ARCHITECTURAL FINISHES. MECHANICAL, ELECTRICAL AND SPRINKLER WILL BE BIDDER DESIGNED. _CODE AND BUILDING. INFORMATION PROJECT NAME: SEATTLE CHILDREN'S HOSPITAL TENANT IMPROVEMENT SITE ZONING: MIC/H KING COUNTY ASSESSOR'S PARCEL NUMBERS: 102304-9082 JURISDICTION: CITY OF TUKWILA APPLICABLE CODES: BUILDING CODE: MECHANICAL CODE: PLUMBING CODE: ELECTRICAL CODE: ENERGY CODE: FIRE CODE: FUEL GAS CODE: 2015 INTERNATIONAL BUILDING CODE (WAC 51-50) 2015 INTERNATIONAL MECHANICAL CODE (WAC 51-52) 2015 UNIFORM PLUMBING CODE (WAC 51-56) 2015 INTERNATIONAL ELECTRICAL CODE WITH WASHINGTON STATE AMENDMENTS 2015 WASHINGTON STATE ENERGY CODE (WAC 51-1IC) 2015 INTERNATIONAL FIRE CODE (WAC 51-54A) 2015 INTERNATIONAL FUEL GAS CODE ACCESSIBILITY CODES: WASHINGTON STATE ACCESSIBILITY CODE (WAC 51-50) USE GROUP AND OCCUPANCY: NO CHANGE TO OCCUPANCY GROUP OCCUPANCY: B ( OFFICE) EXISTING TYPE OF CONSTRUCTION: ICC CONSTRUCTION TYPE IA NUMBER OF STORIES: STORIES ABOVE GRADE PLANE: 3 STORIES BELOW GRADE PLANE: 0 SEISMIC DESIGN CATEGORY: D PROPOSED AREA OF REMODEL: 2,737 SF OF PROJECT AREA CORE AND SHELL FIRE RATINGS: AS EXISTING - NO CHANGE REVISIONS No changes shall be mate to the scope of work without prior approval of itikvvga Building Division NOM ovisicris will require �1 a new plan submittal end may i ic.i:,`de additional plan review fees. INTERIOR FINISHES: PER TABLE 803.9 CLASS C FINISHES WITH EXCEPTION OF EXITS WHERE CLASS B IS USED MEANS OF EGRESS: SEE A-005 - LIFE SAFETY PLAN PARKING: NO CHANGE TO PARKING IS PROPOSED IN CONJUNCTION WITH THE PROJECT.PARKING DEMANDS AS A RESULT OF COMMERCIAL TI ARE MET BY EXISTING SITE PARKING FACILITIES. ALL ACCESSIBLE SITE FEATURES AND PARKING STALLS ARE PROVIDED PER THE BUILDING LANDLORD. tit:warn:sit HILI Preserve 'r Mechanic,l, lnc ne,,ls King CotintyC"3 Metro Soull, iiase. Yo0tirh$1j1, Fork,: 'Aparnnents> 3355 South 1201h Place 51 rievard Palk Place i. ?Inept Community,',' Tukwila' Corn etti itty,COMO' IJSG S ApjiLcalion Support Lenlor Sell,ttle ; Urifort Gospel Mission: Mens Gateway Cow:, 6t6Cen14i mYrian Medical A ReitinrIcI1;. (PROPERTY) LEGAL DESCRIPTION LOT 5 BOUNDARY LINE ADJUSTMENT NO 1_02-057 RECORDED UNDER RECORDING NO 20030327900002 AMENDED BY RECORDING NO. 20030725001852, RECORDS OF KING COUNTY, WASHINGTON. Fr SEPARATE PERMIT REQUIRED FOR:, °Chanical Electrical �( mbing Q' as Piping City of Tukwila DUIt„DING DIVISION GENERAL NOTES 1. DO NOT SCALE THE DRAWINGS. Permit Oa 118- O Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: Date: a lc, tx City of Tukwila BUILDING DIVISION 2. VERIFY FIELD CONDITIONS PRIOR TO COMMENCEMENT OF EACH PORTION OF THE WORK. 3. THE CONTRACT DOCUMENTS ARE COMPLEMENTARY, AND WHAT IS REQUIRED BY ONE SHALL BE AS BINDING AS IF REQUIRED BY ALL. THE CONTRACTOR SHALL COORDINATE. ALL PORTIONS OF THE WORK AS DESCRIBED IN THE CONTRACT DOCUMENTS NOTIFY THE ARCHITECT FOR RESOLUTION OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION. 4. DIMENSIONS ARE TO THE STRUCTURAL GRID OR TO FINISH SURFACES, UNLESS OTHERWISE INDICATED. 5. DOORS AND CASED OPENINGS INDICATED NEARBY WALL INTERSECTIONS, SHALL BE LOCATED SO THAT THE EDGE OF THE FINISH OPENING IS SIX INCHES FROM THE FACE OF THE NEARBY WALL UNLESS OTHERWISE INDICATED. ALL OTHER DOORS AND CASED OPENINGS SHALL BE CENTERED BETWEEN ADJACENT WALL INTERSECTIONS. 6. ITEMS INDICATED AS BIDDER DESIGNED SHALL BE DESIGNED AND ENGINEERED BY THE CONTRACTOR AND/OR SUBCONTRACTOR IN COMPLIANCE WITH APPLICABLE LEGAL REQUIREMENTS, INCLUDING COMPREHENSIVE ENGINEERING ANALYSIS BY A QUALIFIED PROFESSIONAL ENGINEER, USING PERFORMANCE AND DESIGN CRITERIA INDICATED. REVIEWED FOR CODE COMPLIANCE ,f,, APPROVED AUG 0 9 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 09 2018 PERMIT CENTER SAB EY Architecture 12201 Tukwila Int' Blvd - 4th Floor Seattle, WA 98168 206.281.8700 sabey.com• SEATTLE CHILDREN'S HOSPITAL OFFICE TI INTERGATE.EAST, BUILDING 5 3355 S 120TH PLACE TUKWILA, WA 98168 MARK I DATE I DESCRIPTION PROGRESS DATE:. 07/09/18 DRAWN BY: CHECKED BY: APPROVED BY: PROJECT NO: AK TS KA Project Number All drawings and written material appearing herein constitute the original and unpublished work of the Sabey Corporation and the same may not be duplicated, used or disclosed without the written consent of the Sabey Corporation. • 1 COVER SHEET AND PROJECT INFORMATION A-001 r i PROJECT NOTES DIVISION I - GENERAL CONDITIONS DIVISION IX - FINISHES H. REFERENCES 1. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM): A. A641 -ZINC-COATED GALVANIZED CARBON STEEL WIRE: B. C635 - METAL SUSPENSION SYSTEMS FOR ACOUSTICAL TILE AND LAY -IN PANEL CEILINGS. C. C645 - NON-LOADBEARING STEEL STUDS RUNNERS AND RIGID FURRING CHANNELS: - INSTALLATION STEELMEMBERS5. D. C745 NSTA LATION OF FRAMING TO RECEIVE SCREW -ATTACHED GYPSUM WALL BOARD; BACKING BOARD, OR WATER-RESISTANT BACKING BOARD. 2. UNDERWRITERS LABORATORIES (UL): STANDARD 2079 - TESTS FOR FIRE RESISTANCE OF BUILDING JOINT ( ) SYSTEMS. 09500 - CEILING SUSPENSION SYSTEMS. 4. FIRE EXTINGUISHERS SHALL BE BY UNDERWRITER'S LABORATORY EXTINGUISHER WITH SQUEEZE -TYPE HANDLE AND FLEXIBLE DISCHARGE GAUGE. FIRE EXTINGUISHERS SHALL BE INSTALLED IN PER BUILDING 6: DESIGN BUILD FIRE PROTECTION DRAWINGS INDICATE: A. LAYOUT, LOCATION, AND SIZE OF SPRINKLER LINES AND HEADS. B. PRESSURE REQUIREMENTS: C. SPRINKLER HEAD SPECIFICATIONS. D. LOCATION OF FIRE PROTECTION RISERS AND WALL HYDRANTS 7. CONTRACTOR PROVIDE INSTALLATION DESIGN DOCUMENTS REVIEW AND APPROVAL PRIOR TO INSTALLATION. VENTILATING15800.-HEATINGAND AIR CONDITIONING 2A-10BC 5 -LB, MULTIPURPOSE HOSE WITH VISIBLE PRESSURE STANDARD REQUIREMENTS, UON. '- TO ARCHITECT AND BUILDING OWNER FOR LABOR AND ACCESSORIES FOR HVAC SYSTEM AS REQUIRED. PERMIT. & REGISTERS. TO ARCHITECT AND OR DAMAGED HVAC GRILLS: MEET THE TENANT'S REQUIREMENTS. AND OPERABLE ELECTRICAL SYSTEM. ON THE POWER AND DATA PLAN. EACH ON DRAWINGS. COORDINATE DATA THE CENTER LINE, UON. DEVICES SHALL BE GANGED UON. PER CODE. "ISOLATED GROUND" OUTLETS SHALL BE BE ORANGE WITH A GREEN DOT FOR "CLEAN CIRCUIT' FIXTURES SHALL ALL COVERPLATES SHALL BE BUILDING THE TELEPHONE SWITCH, DOCUMENTS. USE OF ELECTRICIANS DURING THE AND CONDUIT SHALL BE CONCEALED TO BE PROVIDED BY TENANT'S VENDORS FURNITURE SYSTEMS TO INCLUDE J -BOX LOCATIONS, CONNECTIONS AND DRILL LOCATIONS AND FILL AS REQUIRED LOCATIONS TO BE PREPARED TO SHOWN. SWITCHING AND AS -BUILT DRAWINGS AND WORK SHALL BE COMPLETED IN ELECTRICAL, AND ON PLAN SHALL BE SET TO A THE MINIMUM DIMENSION REQUIRED: SHALL BE FIELD REVIEWED BY THE TO ARCHITECT FOR REVIEW PRIOR TO & DATA DEVICES. REFER TO DESIGN/BUILD FOR EACH DISCIPLINE. OF DEVICES. COORDINATE EXACT WITH INTERIOR ELEVATIONS, WHERE REQUIRED FOR POWER/DATA AND CASEWORK. TO ARCHITECT AND BUILDING OWNER FOR CEILING PLAN. ALL SWITCHES SHALL BE HANDICAPPED CODES AND ALL SWITCHES SHALL BE GANGED UON. DIMENSIONS ARE TO BE LOCATED IN PER DESIGN LAYOUT AND TO MEET PERMIT AS A DESIGN BUILD PROJECT. BY LANDLORD PRIOR TO OR CEILING -HEIGHT PARTITIONS, AND WITH OCCUPANCY SENSORS, PER CODE: TO ARCHITECT AND BUILDING OWNER FOR RECEIVED CITYOFTUKWILA JUL 0 9 201 „........._",.......r....„.. 01010 SUMMARY OF WORK 09250 GYPSUM DRYWALL AND METAL STUDS 1. GENERAL DESCRIPTION OF THE PROJECT: NON-STRUCTURAL INTERIOR TENANT IMPROVEMENT OF A COMERCIAL OFFICE SUITE " 2. WHERE NO BUILDING STANDARDS EXIST FOR MATERIALS CALLED OUT AS BUILDING STANDARD ON THE PLANS, THE CONTRACTOR SHALL SO ADVISE SABEY ARCHITECTURE WITHIN TEN (10) DAYS OF THE CONTRACTOR'S RECEIPT OF THE PLANS SO THAT SABEY ARCHITECTURE MAY MAKE ALTERNATE SELECTIONS: 3. CONTRACTOR SHALL VERIFY ALL REQUIREMENTS OF EXACT SIZE AND QUANTITY OF EQUIPMENT FURNISHED BY THE TENANT, INCLUDING REQUIREMENTS FOR MECHANICAL AND ELECTRICAL SERVICES, AND -I IS RESPONSIBLE FOR ALL ROUGH -IN CONNECTIONS. EACH SUBCONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ADJACENT WORK AND SHALL REPAIR SAID DAMAGE AT THEIR OWN EXPENSE. 4. FIRE/EMERGENCY SYSTEMS INCLUDE, BUT ARE NOT LIMITED TO, SPRINKLER MODIFICATIONS, FIRE EXTINGUISHER PLACEMENT, AUDIBLE ALARMS, SMOKE AND HEAT DETECTORS, STROBES AND EXIT SIGN PLACEMENT. 5. CONTRACTOR SHALL FURNISH SHOP DRAWINGS FOR APPROVAL ON CABINETWORK, MILLWORK AND ANY OTHER SPECIAL ITEMS REQUIRING CUSTOM SHOP FABRICATION WORK: SUBMIT TO ARCHITECT THREE (3) COPIES FOR APPROVAL. 6. MECHANICAL AND ELECTRICAL TO BE DESIGN BUILD UNDER SEPARATE PERMIT. 7. WORK NOT INCLUDED: CONTRACTOR SHALL PROVIDE THE FOLLOWING ITEMS DESCRIBED IN THE SPECIFICATIONS AND SHOWN ON THE PLANS EXCEPT FOR THE ITEMS INDICATED "N.LC.'' (NOT IN CONTRACT); SUCH AS TELEPHONE AND DATA CABLES, OFFICE FURNITURE, EQUIPMENT AND MOBILE KITCHEN APPLIANCES. 8: CONTRACTOR TO PROVIDE ALL FIRE/EMERGENCY SYSTEMS AS REQUIRED BY ALL APPLICABLE CODES: FIRE/EMERGENCY SYSTEMS INCLUDE BUT NOT LIMITED TO SPRINKLER MODIFICATIONS, FIRE EXTINGUISHERS, AUDIBLE ALARMS, STROBES, SPRINKLERS, SMOKE AND HEAT DETECTORS, AND EXIT SIGNS: KEY EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A K Y OR ANY SPECIAL KNOWLEDGE OR EFFORT, AND SHALL BE EQUIPPED WITH PANIC HARDWARE WHERE REQUIRED AND INDICATED. 10. ANY MATERIAL USED IN CONSTRUCTION SHOULD MEET CURRENT FLAME CO DE REGULATIONS. 11. ALL ELECTRICAL, PLUMBING AND MECHANICAL MATERIAL INSTALLATIONS SHALL COMPLY WITH THE BUILDING SHELL STANDARD SPECIFICATIONS. DIVISION II _ SITE WORK 1: INCLUDE NECESSARY MATERIALS, LABOR AND ACCESSORIES FOR THE INSTALLATION OF ALL PARTITIONS AS SHOWN IN THE PLANS. 2. WALL SURFACES MEAN ALL VERTICAL SURFACES INCLUDING COLUMNS WHERE EXPOSED, CONVECTOR RETURNS. OR RADIATOR ENCLOSURES, FASCIAS, PLYWOOD BACKBOARDS ETC. - 3. ALLPARTITION HEADS SHALL MATCHI BUILDING STANDARD UON. 4. WALLS SHOWN ALIGNED WITH BASE BUILDING STRUCTURE SHALL BE FLUSH AND SMOOTH WITH BASE BUILDING STRUCTURE, UON. 5. SEISMIC BRACING: PROVIDE SEISMIC BRACING AS REQUIRED PER THE LATEST BUILDING CODES (NEW CONSTRUCTION ONLY) TO THE PARTITION HEADS AND CEILING GRID. 6: CONTRACTOR SHALL PROVIDE AND LOCATE ACCESS PANELS AS REQUIRED AFTER INSTALLATION OF "REQUIRED. MECHANICAL DUCTS PLUMBING, EAND LECTRICAL WORK. FIRE RATE AS "MIR" 7. ALL DRYWALL TO BE 5/8 TYPE X' UNILESS OTHERWISE NOTED. PROVIDETYPE DRYWALL WHERE . AND BEHIND CERAMIC TILES UON. REQUIRED BY CODE AND AT ALL TOILET ROOMS, , 8. INSTALL CORNER BEADS AT ALL EXTIERNAL CORNERS. INSTALL METAL EDGE TRIM AT AT WHENEVER EDGE OF GYPSUM BOARD WOULD OTHERWISE BE EXPOSED OR SEMI -EXPOSED. - 9. PRIOR TO RECEIVING FINISH ALL SURFACES SHALL BE PROPERLY PREPARED AS REQUIRED TO RECEIVE FINAL FINISHING AS SPECIFIED: ALL PIPES DUCTS CONDUIT OUTLETS SWITCHES ETC. ON BOTH 10. USE ACOUSTICAL SEALANT AROUND, SIDES OF CROSSING/PENETRATING WALLS WITH ACOUSTICAL INSULATION. PENETRATIONS OF FIRE -RATED WALLS SHALL BE PROTECTED BY APPLICABLE FIRE -RATED ASSEMBLIES. 11. NON-STRUCTURAL METAL FRAMING OUTLINE SPECIFIATION: A. SYSTEM DESCRIPTION: 1. SELECT FRAMING SYSTEMS, GAGES, SUPPORTS BRACING AND CONNECTIONS AS NECESSARY TO RESIST THE STRUCTURAL DESIGN LOADS SPECIFIED. 2. PARTITION FRAMING SHALL CONFORM TO THE WIDTHS INDICATED UNLESS APPROVED OTHERWISE. PROVIDE HEAVIER GAGES AND DECREASED STUD SPACING AS NECESSARY TO MEET THE STRUCTURAL REQUIREMENTS. 3: STRUCTURAL REQUIREMENTS: A. DESIGN LOADS: 5 POUNDS PER SQUIARE FOOT UNIFORM LIVE LOAD PLUS DEAD LOADS: B. DEFLECTION REQUIREMENTS: MAXIMUM OF 1/240 THE SPAN. C. SELECT FRAMING MEMBERS BASED ON THE MANUFACTURER'S PUBLISHED SPAN TABLES: B. CODE REQUIREMENTS: 1. PROVIDE ASSEMBLIES MEETING THE HOURLY FIRE RATINGS INDICATED AND SPECIFIED. ASSEMBLIES SHALL HAVE BEEN TESTED IN ACCORDANCE VVITH ASTM E119, AND SHALL BE APPROVED BY THE LOCAL JURISDICTIONAL CODE AUTHORITIES. COORDINATE INSTALLATION OF OTHER MATERIALS THAT ARE A PART OF EACH ASSEMBLY. 2. FIRERATED CONSTRUCTION JOINT ASSEMBLIES AT PARTITION HEADS SHALL HAVE BEEN SUCCESSFULLY . I N J TESTED IN ACCORDANCE WITH THE DYNAMIC REQUIREMENTS OF UL 2079, INCLUDING HOSE STREAM TEST, TO MEET THE HOURLY FIRE RATINGS OF THE CONSTRUCTION BEING SEALED. C. MATERIALS: 1. LIGHT GAGE METAL FRAMING: ASTM C645; GALVANIZED; PROVIDE "C" SHAPED STUDS, U SHAPED RUNNERS, HAT SHAPED FURRING CHANNELS, AND OTHER SIZES AND SHAPES AS INDICATED; MINIMUM 20 GAGE. 2. FIRE RATED PARTITION HEAD SYSTEMS:1. A. RUNNER: "FIRE TRAK" BY FIRE TRAK CORPORATION, KIMBALL MN (612-398-7800): B. MINERAL WOOL PACKING MATERIAL AND VOID FILL MATERIAL PER UL RATED ASSEMBLIES FOR DYNAMIC WALL HEAD CONDITIONS AS DETAILED IN THE DRAWINGS. F - �, SCREWS: SELF TAPPING; LOW PROFILE HEAD. 4. OTHER FRAMING MATERIALS: FURNISH IN ACCORDANCE WITH ASTM C754: D. J PARTITION FRAMING: 1. RUNNERS: A. SECURE FLOOR RUNNERS WITH FASTENERS AT MAXIMUM 24 INCHES 0.C. AT CONCRETE FLOORS, USE POWDER DRIVEN FASTENERS OR DRILLED IN CONCRETE ANCHORS. VERIFY LOCATION OF TENDONS AND CONDUIT WHICH MAY BE EMBEDDED IN CONCRETE FLOORS. B. WHERE WALLS ARE INDICATED AS NOT BEING CONTINUOUS TO STRUCTURE ABOVE, ATTACH TOP RUNNER TO ACOUSTICAL CEILING GRID WITH SCREWS AT 24 INCHES ON CENTER. PROVIDE SPACER STRIP BETWEEN RUNNER AND CEILING SUSPENSION SYSTEM TO ALLOW TEGULAR OR REVEAL EDGE ACOUSTICAL PANELS TO CLEAR PARTITION. C. INSTALL FIRE RATED PARTITION HEAD SYSTEMS IN ACCORDANCE WITH THE UL ASSEMBLIES INDICATED ON THE DRAWINGS TO MEET THE SPECIFIED FIRE RATING REQUIREMENTS. D. PROVIDE 2 INCH EXTENDED LEG OVEERHEAD TRACK AT FULL HEIGHT PARTITIONS SUBJECT TO STRUCTURAL DEFLECTION. 2: UNLESS INDICATED OTHERWISE, INSTALL STUDS VERTICALLY AT 16" ON CENTER, AND NOT MORE THAN 2 INCHES FROM ABUTTING CONSTRUCTION, AT EACH SIDE OF OPENINGS, AND AT CORNERS. 3. BRACE PARTITION FRAMING SYSTEM AND MAKE RIGID. PROVIDE DIAGONAL STUD BRACING AT 8 FT ON CENTER AT ALL FRAMING THAT DOES NOT EXTEND TO STRUCTURE: 4. INSTALL DOUBLE STUDS CONTINUOUS FROM FLOOR TO TOP TRACK AT THE JAMB OF EACH DOORFRAME AND CASED OPENING. STUDS SHALL HAVE THE SAME GAGE AS THE ADJACENT STUDS; BUT IN NO CASE LESS THAN 20 -GAGE. 5. PROVIDE MINIMUM 20 GAGE STUDS AT ALL PARTITIONS SUPPORTING CASEWORK OR COUNTER TOPS. 6. COORDINATE ERECTION OF STUD SYSTEM WITH REQUIREMENTS OF DOOR AND RELITE FRAMES, FIRE EXTINGUISHER CABINETS, AND OTHER CONSTRUCTION WITHIN MOUNTED PARTITION CONSTRUCTION. 7. COORDINATE THE INSTALLATION OF FRAMING WITH THE GYPSUM BOARD INSTALLER TO ENSURE SUPPORT AT ALL BOARD EDGES. 8. AT NON -LOAD BEARING FULL HEIGHT PARTITIONS SUBJECT TO COMPRESSION CAUSED BY OVERHEAD STRUCTURAL DEFLECTION, CUT STUDS 1/2 INCH SHORT FROM FULL HEIGHT: DO NOT RIGIDLY CONNECT STUD TO TOP RUNNER. 9. STUD BRIDGING: A. AT INTERIOR PARTITIONS GREATER THAN 4 FEET IN LENGTH, AND WITH RIGID FACING MATERIAL ON ONE STUD FLANGE ONLY, PROVIDE 3/4" BRIDGING CHANNELS IN HORIZONTAL ROWS AT A MAXIMUM OF 5'-0" ON CENTER FOR THE FULL HEIGHT OF THE PARTITION.: B. INTERIOR FULL HEIGHT PARTITIONS (STUDS EXTENDING FROM THE FLOOR TO THE STRUCTURE ABOVE) WITH RIGID FACING MATERIAL STOPPINIG 3'-0" OR MORE BELOW TOP OF STUDS: PROVIDE ONE ROW 3/4" BRIDGING CHANNEL HORIZONTALLY AT TERMINATION OF GYPSUM BOARD MATERIAL, AND ONE ADDITIONAL ROW FOR EACH 5'-0" OF EXPOSED STUDS. C. INSTALL STUD BRIDGING CHANNELS IN LONG LENGTHS, WIRE TYING AND LAPPING THE JOINTS A MINIMUM OF 12." ATTACH BRIDGING CHANNEL TO EACH STUD AS SHOWN IN MANUFACTURER'S PRINTED INSTRUCTIONS. E. CEILING AND SOFFIT FRAMING: PRO\/IDE METAL STUD FRAMING. IN THE CONFIGURATIONS INDICATED. F. BACKING: 1: PROVIDE STEEL BACKING, UNLESS INDICATED OTHERWISE, FOR THE SUPPORT OF WALL MOUNTED ITEMS. 2. UNLESS INDICATED OTHERWISE, STEEL BACKING SHALL CONSIST OF MINIMUM 4 INCH WIDE 16 GAGE STEEL PLATE SCREWED RIGIDLY TO THE STUDS. PROVIDE BACKING WITH RETURNED EDGES AT DOOR STOP LOCATIONS. PROVIDE 12 GAGE BACKING PLATES AT HANDRAILS: 3. FIRE RETARDANT TREATED WOOD BACKING MAY BE USED AT THE CONTRACTOR'S OPTION. ALL FIRE RETARDANT TREATED WOOD MATERIALS SHALL BEAR A UL "FR -S" LABEL, OR A LABEL FROM AN APPROVED INSPECTION AGENCY CERTIFYING THAT THE MATERIAL MEETS THE REQUIREMENTS OF AWPA C-20 TYPE A FOR LUMBER AND AWPA C-27 TYPE A FOR P LYWOOD. G. INSTALLATION TOLERANCES: 1. INSTALL MEMBERS TO PROVIDE SURFACE PLANE WITH MAXIMUM VARIATION OF 1/8 INCH IN 10 FEET IN ANY DIRECTION. 2. LOCATE ASSEMBLIES WITHIN 1/4 INCH OF REQUIRED LOCATIONS. 1: PROVIDE NEW CEILING TILE, CEILING GRID AND ALL ACCESSORIES AS REQUIRED TO INSTALL SUSPENDED ACOUSTICAL CEILINGS AS INDICATED ON DRAWINGS. 2. PROVIDE SEISMIC BRACING AS REQUIRED BY CODE AT NEW CEILING WORK ONLY. 3: COORDINATE WORK WITH OTHER TRADES HAVING WORK IN THE CEILING AND THETELEPHONEABL CABLE COMPANIES WHEREVER THEIR RESPECTIVE WORK IS CONTIGUOUS. 4. PROVIDE CUTOUTS AND OTHER SPECIAL PROVISIONS IN ACOUSTICAL WORK AS REQUIRED FOR LIGHTING FIXTURES REGISTERS DIFFUSERS SPRINKLERS AND OTHER INSERTED ITEMS. ALL CUTOUTS SHALL BE CENTEREDW HI 5 . WITHIN T 6. ALL MATERIALS SHALL HAVE CLASS 1 FLAME SPREAD RATING AND BE INSTALLED IN ACCORDANCE WITH F SPECIFICATIOND MANUFACTURERS S AND CODES. 7. ALL JOINTS IN THE TILE FILED SHALL BE SQUARE, LEVEL AND PERFECTLY ALIGNED WITH EACH OTHER. 8. INSTALLED SUSPENDED CEILINGS TO BE LEVEL WITHIN A TOLERANCE OF 1/8„ IN 12'-0". ANCHOR AS REQUIRED., 09530 - ACOUSTICAL TREATMENT 1. PROVIDE BUILDING STANDARD HVAC SYSTEM WITH ALL MATERIALS, COMPLETE OPERATION OF SYSTEM. CONTRACTOR TO BALANCE 2. DESIGN OF MECHANICAL TO BE PREPARED UNDER A SEPARATE 3. DESIGN BUILD MECHANICAL ENGINEERING DRAWINGS INDICATE: A. DUCTS, AIR MOVEMENT REQUIREMENTS, & SIZES OF GRILLES 4. CONTRACTOR PROVIDE INSTALLATION DESIGN DOCUMENTS = BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION: 5. HVAC CONTRACTOR TO CLEAN, REPAIR OR REPLACE SOILED DIVISION XVI - ELECTRICAL 16000 - ELECTRICAL AND TELECOMMUNICATIONS 1. REUSE EXISTING ELECTRICAL AND DATA AS APPROPRIATE TO 2. PROVIDE ALL WORK, EQUIPMENT AND LABOR FOR A COMPLETE PROVIDE ELECTRICAL OUTLETS PER POWER AND DATA PLAN. 3. PROVIDE MUD RING FOR DATA COM COMMUNICATION AS SHOWN MUD RING TO HAVE A MINIMUM NUMBER OF WIRE PULLS AS INDICATED CABLE CONFIGURATION WITH THE TENANT. 4: ALL OUTLETS AND MUDRINGS TO BE LOCATED AT 15" AFF TO 5. WHERE MULTIPLE DEVISES OCCUR IN A SINGLE LOCATIONS, ALL 6. GFI CIRCUITS TO BE LOCATED 24" FROM FAUCET CENTERLINE, 7. ALL WIRING DEVICES: SHALL BE BUILDING STANDARD EXCEPT: ORANGE, "HOSPITAL GRADE ISOLATED GROUND" OUTLETS SHALL "EMERGENCY" OUTLETS SHALL BE RED, AND "DEDICATED" OUTLETS BE GRAY (UNLESS BUILDING STANDARD DICTATES OTHERWISE). STANDARD FINISH, UON. 8. PROVIDE SEPARATE CIRCUITS FOR TENANT'S EQUIPMENT (INCLUDING COPIERS, COMPUTERS, ETC.) WHEN NOTED ON THE CONSTRUCTION 9: COORDINATE SCHEDULE WITH FURNITURE VENDOR FOR THE OF TENANT'S NEW FURNITURE: 10. ALL ELECTRICAL WIRING, TELEPHONE AND COMPUTER CABLING, IN FLOORS, WALLS, OR CEILINGS. CABLING FOR VOICE AND DATA AND SHALL BE COORDINATED BY THE BUILDING MANAGER. 11. THE CONTRACTOR IS TO COORDINATE WITH THE OWNER SUPPLIED BUT NOT LIMITED TO: ELECTRICAL AND DATA WIRING LOCATIONS, WALL MOUNTED REQUIREMENTS. THE CONTRACTOR IS TO VERIFY EXISTING ABANDONED CORE WITH MATERIAL TO MEET CURRENT FLAME SPREAD REGULATIONS. RECEIVE NEW FLOOR: FINISH AS REQUIRED. 13. ARCHITECTURAL DRAWINGS INDICATE LOCATION ONLY OF DEVICES CIRCUITING SHALL BE INDICATED ON SEPARATE ELECTRICAL ENGINEERING SHALL MEET OWNER'S GUIDELINES. 14. ALL TELEPHONE, ELECTRICAL, COMMUNICATION AND SECURITY ACCORDANCE WITH ALL APPLICABLE CODES. 15. DRAWINGS INDICATE ALL DIMENSIONS TO CENTERLINE OF TELEPHONE, COMMUNICATION COVERPLATE. OUTLETS SHOWN GROUPED TOGETHER MINIMUM DIMENSION BETWEEN EACH DEVICE. 16. BACK-TO-BACK OUTLETS ARE NOT PERMITTED. OFFSET OUTLETS 17. LOCATION OF ALL WALL MOUNTED POWER AND DATA DEVICES TENANT BEFORE INSTALLATION. 18. ELECTRICAL ENGINEER TO PROVIDE DESIGN/BUILD PACKAGE INSTALLATION. 19. THE LAYOUT DIAGRAMS COORDINATE LOCATION OF POWER DOCUMENTS FOR. SCOPE, TECHNICAL LAYOUT AND SPECIFICATIONS 20. ARCHITECTS DOCUMENTS INDICATE LOCATION AND RELATIONSHIP LOCATION WITH FURNITURE VENDOR. 21. COORDINATE POWER/DATA & LIGHT FIXTURE MOUNTING LOCATIONS FINISHES & CASEWORK. 22. PROVIDE EXTENSION RINGS AND MOUNTING ACCESSORIES DEVICES AND LIGHT FIXTURES. COORDINATE WITH INTERIOR FINISHES 23. CONTRACTOR PROVIDE INSTALLATION DESIGN DOCUMENTS REVIEW AND APPROVAL PRIOR TO INSTALLATION. 16500 -LIGHTING 1. PROVIDE ACOUSTICAL INSULATION BETWEEN FRAMING STUDS AND EXTENDING TWO FEET ON EACH SIDE OF PARTITION HEAD ABOVE CEILINGS FOR ALL WALLS NOTED PER PLANS. 2. NEW DEMISING WALL CONSTRUCTION TO HAVE SOUND BATT INSULATION BETWEEN FRAMING STUDS AND TWO FEET OF INSULATION ON EITHER SIDE OF THE PARTITION HEAD ABOVE CEILING GRID. - 09650 - RESILIENT FLOORING 1. PROVIDE VCT SHEET LINOLEUM SHEET VINYL AND RUBBER BASE AS INDICATED IN DRAWINGS. COLOR AND MANUFACTURER PER FINISH SCHEDULE: 2. PROVIDE RUBBER -REDUCING STRIPS IN COLOR TO MATCH SPECIFIED BASE. REDUCING STRIPS TO OCCUR AT ALL AREAS OF FLOOR MATERIAL TRANSITION. 3. BASE TO BE INSTALLED IN LONGEST AVAILABLE LENGTH WITH NO PIECE LESS THAN 12". NO JOINTS AT OUTSIDE CORNERS OR WITHIN 6" OF CORNERS. 4. PATCH, LEVEL AND PREPARE SUB FLOORING WITH CEMENTITOUS UNDERLAY PER MANUFACTURER'S WRITTEN INSTRUCTIONS IN AREAS TO RECEIVE NEW FLOORING. MAX. ALLOWABLE TOLERANCE = 1/4" OVER 10'. U COMPLETION ALL 5. PON COMP ET ON A WORK SHALL BE CLEANED AND ALL SPOTS OF ADHESIVE AND SURFACE REMOVED: CONTRACTOR SHALLFLOOR WAXINSTALLATION 6. GENERAL APPLY F OOR TO NEW FLOORING AREAS PER MANUFACTURERS SPECIFICATION UON. 09680 - CARPET 02050 - DEMOLITION 1. FURNISH ALL LABOR MATERIALS AND EQUIPMENT AS REQUIRED TO COMPLETE THE DEMOLITION AND REMOVAL OF ALL ITEMS LOCATED IN THE CONSTRUCTION AREAS. UPON COMPLETION OF ALL DEMOLITION WORK, ALL AREAS SHALL BE LEFT BROOM CLEAN. 2. DEMOLITION OF TELEPHONES, ELECTRICAL, VOICE/DATA AND PANELS ARE TO BE REMOVED BACK TO ORIGINATING SOURCE. DEMOLITION OF CORES AND RELATED CABELING TO BE REMOVED FROM TENANT SPACES BELOW. 3. DURING THE REMOVAL OF ANY ENVIRONMENTALLY HAZARDOUS MATERIALS, PROTECTION GUIDELINES. SHOULD BE STRICTLY FOLLOWED BY CODE OR LOCAL GOVERNING AUTHORITY. 4. ALL EXISTING CONSTRUCTION ITEMS THAT INTERFERE WITH THE CONSTRUCTION PER THE PRICING PLAN SHALL BE REMOVED, RELOCATED, OR KEPT FLUSH IN CEILING, WALL, OR FLOOR AS REQUIRED. 5. ALL DAMAGED AREAS SHALL BE PATCHED AS REQUIRED AND FINISHED TO MATCH EXISTING ADJACENT AREAS OR AS SPECIFIED TO PROVIDE A "LIKE -NEW FINISH". 6. CONTRACTOR SHALL PROVIDE PLASTIC SHEETING OR OTHER APPROPRIATE BARRIER TO CONTROL DUST AND DEBRIS SUCH THAT IT DOES NOT AFFECT AREAS OUTSIDE THE AREA OF WORK. DIVISION VI - ARCHITECTURAL CARPENTRY AND CASEWORK PROVIDE COMMERCIAL GRADE CARPET AS INDICATED IN DRAWINGS. 2. CARPET TO BE INSTALLED AS INDICATED IN DRAWINGS. : 3. PREPARE SUB FLOOR WITH LIGHT WEIGHT CONCRETE UNDERLAY WHERE REQUIRED TO PROVIDE APPROVED SUBSTRATE. MAX. ALLOWABLE TOLERANCE _ OVER12. S OLERANC 1/4 10. 4. PROVIDE SEAMING DIAGRAMS FOR ARCHITECTS REVIEW. - 09900 -PAINTING AND S', AIN 06100 -ROUGH CARPENTRY 1. ROUGH CARPENTRY TO INCLUDE ANY WOOD STUDS, FURRING, BLOCKING, ROUGH FRAMING, WOOD CURBS, BUCKS BACKING FIXTURE FRAMING, EQUIPMENT SUPPORTS, ETC. AS DETAILED. NAILERS 06200 - FINISH CARPENTRY 1. FINISH CARPENTRY TO INCLUDE INSTALLATION OF ALL FIXTURES AND ASSOCIATED TRIMS, HARDWARE AND NOSINGS. 2. PROVIDE INTERIOR DOOR AND SIDELIGHT FRAMES AS SCHEDULED. 06400 - ARCHITECTURAL WOODWORK AND CASEWORK 1. UNLESS OTHERWISE NOTED, PRIME ALL GWB WALL SURFACES AND PAINT WITH MINIMUM OF TWO (2) FINISH COATS OF BENJAMIN MOORE EGGSHELL FINISH LATEX PAINT OR APPROVED EQUAL: PROVIDE FOR NUMBER OF PAINT COLORS AS INDICATED N DRAWINGS. 2. FINISH DOORS, DOOR FRAMES, AND SIDELIGHT FRAMES AS INDICATED IN DRAWINGS. A) PAINTED WOODWORK TO BE FINISHED WITH ONE (1) COAT PRIMER AND TWO (2) FINISH COATS. B) SEALED WOODWORK TO BE STAINED PER FINISH SCHEDULE AND SEALED WITH A COMMERCIAL GRADE CLEAR SATIN VARNISH. 3. PAINT FOR THE LIGHT SURFACES TO CONFORM TO THE REQUIREMENTS OF THE "ARCHITECTURAL "CUSTOM" SPECIFICATIONS MANUAL"(AVNs) FOR PAINT SYSTEMS. LATEX PAINT: AWS SYSTEM 3-B USTOM (2 COAT) GRADE LIGHT COLOR PAINT FINISH ON GYPSUM BOARD SURFACES. 4. PAINT FOR THE DARK SURFACES TO CONFORM TO THE REQUIREMENTS FOR THE "ARCHITECTURAL SPECIFICATIONS MANUAL" (AWS) FOR PAINT SYSTEMS. LATEX PAINT: AWS SYSTEM 3-B "CUSTOM (2 COAT) GRADE DEEP TONE PAINT FINISH ON GYPSUM BOARD SURFACES. - 5. UPON COMPLETION OF WORK, REMOVE EXCESS PAINT, STAIN, VARNISH, ADHESIVE, CAULK, ETC. FROM ALL OTHER SURFACES THAT WERE NOT SPECIFIED TO RECEIVE SAME. 6. TOUCH-UP AND PATCH SURFACES AS REQUIRED AFTER THE COMPLETION OF. WORK BY OTHER TRADES: 7. WHERE COLUMNS OCCUR INAREAS SCHEDULED TO BE FINISHED THEY SHALL RECEIVE THE SAME FINISH AS THE ROOM UON. ' DIVISION XII -FURNISHINGS 1. CABINET CONSTRUCTION: COMPLY WITH THE A.W.I. ARCHITECTURAL WOODWORK QUALITY STANDARDS FOR CUSTOM GRADE WORK. CABINETS SHALL BE FLUSH CONSTRUCTION. PROVIDE PARTICLE BOARD MED. DENSITY WEIGHING <40 LB./CU. FT. " THICK. 3. CABINET HARDWARE: EXTENSION DRAWER GLIDES, STAINLESS STEEL CABINET PULLS, US32D FINISH, AND CONCEALED DOOR HINGES, SHELF HARDWARE AND OTHER REQUIRED ITEMS, UON IN ELEVATIONS / DETAILS. 4. PLASTIC LAMINATE: HIGH-PRESSURE DECORATIVE LAMINATE SELECTED FROM WILSONART, NEVAMAR, PIONITE, AND FORMICA. LAMINATE TO BEGENERAL-PURPOSE GRADE .050" HORIZONTAL AND .030" VERTICAL. 5. INTERIOR CABINET SURFACES AND SHELVES TO BE OF PREFINISHED BOARD WITH POLYESTER OVERLAY. 6. SHELF EDGING TO BE VINYL. DIVISION VIII - DOORS AND WINDOWS 08210 - WOOD DOORS 1. PROVIDE AND INSTALL INTERIOR SUITE DOORS AS INDICATED ON DRAWINGS. 2. DOOR SCHEDULE SPECIFIES FINISH (BOTH SIDES OF DOOR) AND FRAME UNLESS OTHERWISE NOTED. 3. DOORS SHALL BE PRE -MACHINED FOR HARDWARE PER HARDWARE SCHEDULE. 4. PROVIDE SHOP DRAWING SUBMITTALS FOR ARCHITECT REVIEW. 08710 - FINISH HARDWARE 12500 - WINDOW TREATMENT 1. ALL PERIMETER GLAZING TO RECEIVE BLINDS AS INDICATED IN DRAWINGS. COORDINATE WITH BUILDING MANAGEMENT. 2. ALL INTERIOR RELITES TO RECEIVE 1" MINI -BLINDS WHERE INDICATED IN DRAWINGS. 3. PROVIDE SAMPLE AND CUT SHEET TO ARCHITECT FOR REVIEW. DIVISION XV - MECHANICAL 1. LOCATION OF SWITCHES SHALL BE SHOWN ON THE REFLECTED MOUNTED AT A MAXIMUM HEIGHT OF 48" A.F.F. TO MEET THE LATEST REGULATIONS. 2. WHERE MULTIPLE SWITCHES OCCUR IN A SINGLE LOCATION, 3. DOWN LIGHTS SHOWN IN THE CENTER OF CEILING TILE WITHOUT THE CENTER OF CEILING TILE, UON. 4. REUSE ALL EXISTING B/S FLUORESCENT FIXTURES AS NEEDED LOCAL ENERGY CODE COMPLIANCE. 5: DESIGN OF ELECTRICAL TO BE PREPARED UNDER A SEPARATE PERMIT DRAWINGS TO BE REVIEWED AND APPROVED IN WRITING COMMENCEMENT OF WORK. 6. ALL OFFICE AREAS LESS THAN 300 SQ. FT. ENCLOSED BY WALLS ALL MEETING AND CONFERENCE ROOMS, SHALL BE EQUIPPED 7. DESIGN BUILD ELECTRICAL ENGINEERING DRAWINGS INDICATE:. A. CIRCUITING AND WIRING OF LIGHT FIXTURES, AND SWITCHES. B. LIFE SAFETY EQUIPMENT. C. LOCATION OF REQUIRED EMERGENCY LIGHT FIXTURES: D. LIGHT FIXTURE SPECIFICATIONS 8. CONTRACTOR PROVIDE INSTALLATION DESIGN DOCUMENTS REVIEW AND APPROVAL PRIOR TO INSTALLATION.. R ‘:\ 1 11 6 � 1. FINISH AND SPECIALTY HARDWARE INCLUDES ALL ACCESSORIES, TOOLS; AND FASTENERS REQUIRED FOR HARDWARE INSTALLATION AND MAINTENANCE. ITEMS NOT SPECIFICALLY MENTIONED, BUT NECESSARY TO COMPLETE THE WORK, SHALL BE FURNISHED MATCHING IN QUALITY AND FINISH OF SPECIFIED IN SIMILAR LOCATIONS. 2. PROVIDE ALL HARDWARE AS SPECIFIED PER THE HARDWARE SCHEDULE. 3. ALL LOCK SETS SHALL CONFORM TO THE BUILDING'S GRAND MASTER KEYING SYSTEMS. PROVIDE TWO (2) KEYS FOR EACH LOCK AND TWO (2) MASTER KEYS FOR THE SUITE. ALL KEYS TO BE TAGGED WITH ROOM NUMBERS. 4SUBMIT HARDWARE SCHEDULE WITH CATALOGUE CUT SHEETS FOR ARCHITECT REVIEW. 5. ALL DOORS SHALL HAVE A MINIMUM OF 1-1/2 PAIR OF BUTT HINGES, ONE LATCHSET OR LOCK SET, AND MEET A.D.A. REQUIREMENTS. ONE DOOR STOP TO Q 6. ALL HARDWARE SHALL BE COMMERCIAL GRADE. 7. PROVIDE CLOSERS PER HARDWARE SCHEDULE. 08810 - GLASS 15400 - PLUMBING 1. PROVIDE SUPPLY, WASTE AND VENT LINES, VALVES, FITTINGS, ETC. REQUIRED FOR KITCHEN SINKS, DISHWASHER, REFRIGERATOR, AIR CONDITIONING UNIT(S), VENDING MACHINES, COFFEE MAKER, WATER HEATERS, ETC. 2. ALL FIXTURE INSTALLATIONS SHALL CONFORM TO THE AMERICAN WITH DISABILITIES ACT. 3. PROVIDE NEW PLUMBING FIXTURES AS SPECIFIED PER DRAWINGS. 4. PROVIDE HOT AND COLD WATER TO SINKS/DISHWASHERS. 5. ALL NEW WATER HEATERS ARE 0 BE INSTALLED WITH DRIP PAN. 6.ALL PLUMBING FIXTURES TO ARE TO BE INSTALLED TO MEET CURRENT GOVERNING LOCAL AND FEDERAL CODES. 7. CONTRACTOR PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INCTALLATION. 15500 - FIRE PROTECTION 1. ALL GLASS AT SIDELIGHTS AND DOORS SHALL BE 1/4" TEMPERED SAFETY GLAZING, UON. WILL BE SUBJECT TO FEDERAL GLAZING STANDARDS. GLAZING 2. THIS PROJECT CONTAINS GLAZING THAT IL SUBCONTRACTOR SHALL BE RESPONSIBLE FOR ADHERENCE TO THE REQUIREMENTS: IF GLAZING SUBCONTRACTOR FINDS ANYTHING IN THE DOCUMENTS NOT IN COMPLIANCE WITH THE STANDARD, THEY SHALL BRING DISCREPANCIES TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. 1. FIRE PROTECTION SYSTEM PER BUILDING STANDARD AND LOCAL REGULATIONS AND ORDINANCES. 2. PROVIDE ALL EMERGENCY LIGHTING, EXIT SIGNS, FIRE ALARM SPEAKERS, STROBES AND BELLS AS REQUIRED BY CODE. DESIGN AND INSTALL THE SAME IN COMPLIANCE WITH THE AMERICANS WITH DISABILITIES ACT: - 3: PROVIDE SPRINKLERS, FIRE RATED DOORS AND FRAMES, FIRE EXTINGUISHERS, ETC. AS REQUIRED BY APPLICABLE LOCAL CODES AND LAWS. SfreB EY Architecture 12201 Tukwila Int' Blvd - 4th Floor Seattle, WA 98168 206.281.8700 •sabey.com EARA M. ANDERSON STATE OF WASHINGTON SEATTLE CHILDREN'S HOSPITAL OFFICE TI INTERGATE.EAST, BUILDING 5 3355 S 120TH PLACE TUKWILA, WA 98168 REVIEWED FOR CODE COMPLIANCE APPROVED. AUG 0 9 2018 City of Tukwila BUILDING DIVISION MARK I DATE DESCRIPTION PROGRESS DATE: 07/09/18 DRAWN BY: AK CHECKED BY: TS APPROVED BY: KA PROJECT NO: Project Number AH drawings and written material appearing herein. constitute the original and unpublished work of the Sabey Corporation and the same may not be duplicated, used or disclosed without the written consent of the Sabey Corporation. NOTES AND SPECIFICATIONS A-002 OD 10 / ///////////////////////////////////////////////////////��� / / / / / / / / / /////// CINTERGATE.EAST, BUI 1"=40'-0 /\ 0 //A1 o / / / ///////////////////i / 0 BUILDING 5 3355 S. 120TH PL 0 a.. a a.. a.... ti.... x...011, �-... CLQ LDING 5 SITE PLAN Coco c_palio0112 (112C° / 0 o 00 0 0 o°o 0 0' / 00 0 0 0 0 0 0 0P;; 0 • n-\\ ////// //////////,C////7/////// 00 0 I C) • • • -0- � — 1 C0 X X 1)1 VACATED 35TH AVENUE AREA OF WORK ON THE FIRST FLOOR o REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 9 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 092018. PERMIT CENTER SAB EY Architecture 12201 Tukwila Int' Blvd - 4th Floor Seattle, WA 98168 206.281.8700 sabey.com SEATTLE CHILDREN'S HOSPITAL OFFICE TI INTERGATE.EAST, BUILDING 5 3355 S 120TH PLACE TUKWILA, WA 98168 MARK I DATE I DESCRIPTION PROGRESS DATE: 07/09/18 DRAWN BY: CHECKED BY: APPROVED BY: AK TS KA PROJECT NO Project Number • All drawings and written material appearing herein constitute the original and unpublished work of the Sabey Corporation and the same may not be duplicated, used or disclosed without the written consent of the Sabey Corporation. SITE PLAN A-003 .. 4 10 SEATTLE CHILDREN'S OFFICE SPACE e PARTIAL FIRST FLOOR LIFE SAFETY PLAN 118" =1-0" LIFE SAFETY LEGEND. INDICATES PATH OF TRAVEL — INDICATES PATH OF TRAVEL TRAVEL DISTANCE START POINT COMMON PATH OF TRAVEL INTERSECTION XXXX XXX XX EXIT AND LOAD OCCUPANCY FLOOR AREA (SF) OCCUPANT LOAD LOAD FACTOR PER IBC 100412 EXISTING EXIT SIGN NEW EXIT SIGN OT EXIT SIGN WITH DIRECTIONAL ARROW ®N. OCCUPANCY CALCULATIONS B -OFFICE 2,737 SF/ 100 SF PER OCCUPANT = 27 OCCUPANTS AREA NOT IN SCOPE TOTAL TENANT IMPROVEMENT SQUARE FOOTAGE TOTAL OCCUPANCY NUMBER OF EXITS REQUIRED NUMBER OF EXITS PROVIDED OCCUPANT LOAD PER EXIT REQUIRED EXIT WIDTH EXIT DOOR WIDTH PROVIDED 2,737 SF 27 OCCUPANTS 1- 1 27 27x.15=4" 3'-0" (32" CLEAR) CODE ANALYSIS TYPE OF CONSTRUCTION: TYPE IA, FULLY SPRINKLERED OCCUPANCY CLASSIFICATION: B OCCUPANCY (BUSINESS) EXITING REQUIREMENTS: OCCUPANT LOAD FACTOR (2015 IBC TABLE 1004.1.2) BUSINESS AREAS: 100 GROSS EGRESS WIDTH PER OCCUPANT: USE (SPRINKLERED) STAIRWAYS (INCH!OCCUPANT) OTHER EGRESS COMPONENTS (INCH/OCCUPANT) B OCCUPANCY 0.2 0.15 TRAVEL DISTANCES: 1. MAXIMUM ALLOWED DEAD END CORRIDOR LENGTH: 50'-0" (IBC 1020.4, EXEMPTION 2) 2. MAXIMUM ALLOWED COMMON PATH OF EGRESS TRAVEL :100'-0" (IBC TABLE 1006.2.1) 3. MAXIMUM ALLOWED EXIT ACCESS TRAVEL DISTANCE: 250'-0" (IBC TABLE 1017.2) REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 9 2018 City of Tukwila BUILDING DIVISION RECEIVED - CITY OF TU i�WILA JUL 092018 PERMIT CENTER SAB EY Architecture 12201 Tukwila Int' Blvd - 4th Floor Seattle, WA 98168 - 206.281.8700 sabey.com SEATTLE. - CHILDREN'S HOSPITAL OFFICE TI INTERGATE.EAST, BUILDING 5 3355 S '120TH PLACE TUKWILA, WA 98168 MARK I DATE I DESCRIPTION PROGRESS DATE: 07/09/18 DRAWN BY: AK CHECKED BY: - TS APPROVED BY: - • KA PROJECT NO: Project Number tkr All drawings and written material appearing herein constitute the original and unpublished work of the Sabey Corporation and the same may not be duplicated, used or disclosed without the written consent of the Sabey Corporation. LIFE SAFETY PLAN A-005 1- -2 3 4 5 6 7 8 10 F DICWORK 01 125 SF CPT -2) IDF 02 68 SF `</ ‘;•7-/ • \ // • / / / 7 • -----NOWORK (F OFFICE 04 1363 SF CPT -1 ) 2 a 35 - 4" "•• ALIGN .:711 FIRST FLOOR CONSTRUCTION PLAN 1/8" = 1-0" NOC 05 710 SF (F CPT -1) EXISTING SUITE 121 06 ALIGN 7 /7. „./ \ \ / \\// 7</ ,, '7 7,;/ 7 / ‘•••7„ / • , \ • . , . 2s. ,==- /7 '- / ‘\ 7-•-• . / . 7' '\ 77/ \ \Y / / \/ ,'. ' '/ -0,3 / \ / / •, ,/ \\ ..,,,,/ \\ / \ .' V\ / ›K / \ , z'' 777/ / , \/ N‘ //X ' 7/77 / / / \ '' </ ' /.\' \/ 7 ' ‘1 /( 7- /7< / ./ /1.77 \71..."7 ' ••••. \ \ • /•••./ \ , /77, / \‘,/ co LL 7' \ /7 - s ," -,. • \ • A / 77\ \ / /.. / "\\ / ""y/-", \ >( 7<22 \/: /><` \ \ 7\ 7\ ;< / / \ ' , "/ / / 7/ , / \ 7‹ • \ \/< \' , / /\‘ \>„<, >`"/„... • s/ ' , \ , / / \,/ \ \ . \ / \\ / / x , /•\ / )<, Y ' •,/ / //' / x , / /7 , 7' , z ' / / • •/ /". 7/ / \ "„ , •"..\•,./ • •\/ 7( • .1\7' ."/ \ / \ \ • "/ / • \ / . / // / \\ • -•„, 7.„ . \_„/ \ 0 7./ \-/ \ / \- 7. • • 7 7\/ „/ \ • /, \‘„, / /C "\ \\ / v \/ \ \< / \ \ \ / • \\\ /z \ \ / / \ /77<7 „ \, \ / -- . \<2/cK /.„/ /\ //7 // „‹\ „ • ;</ \ • ' 2`: 77 /7 \' • / • <"" .\\' \,"y, / ••••• / 7' \\ • \‚7/7,7 / \ / s,/ /7/ ," . \ \ 7/ ',/7,• / \ / 77 7- • , \// ' ,‘>/ \ </ \ N \ \ / \ . • /77/"7<2 7-7 /7<7,„/- /27,7 ‘7, \ /' FLOOR PLAN NOTES: 1. REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS. 2, GENERAL CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF WORK 3. ALL INTERIOR PARTITION, PENETRATIONS, AND OTHER OPENINGS IN THE BUILDING SHELL SHALL BE SEALED, GASKETED, OR WEATHER STRIPPED AS REQUIRED TO MEET PARTITION RATINGS. 4. WHERE PARTITION LAYOUT INTERSECTS EXISTING SHELL/CORE GYPSUM BOARD, REMOVE EXISTING CORNER BEADS AND OTHER ACCESSORIES, ALIGN FACE OF PARTITIONS, TAPE & SAND SMOOTH FOR NEW FINISH. 5. PROVIDE PARTITION ANCHOR BRACKETS FOR ALL CASEWORK FIXTURES, EQUIPMENT, & DEVICES MOUNTED ON OR ATTACHED TO PARTITIONS. 6. ALL WOOD USED IN INTERIOR FRAMING IS TO BE FIRE-RETARDENT TREATED WOOD. 7. UON, ALL PARTITIONS A 2 a 8. DOORS AND CASED OPENINGS WITHOUT DIMENSIONS OR DETAILS ARE TO BE LOCATED 6” FROM ADJACENT WALL OR MATCH EXISTING SUITE STANDARD. 9. FOR TYPICAL DEVICE MOUNTING HEIGHTS, SEE 3 / A-601 FLOOR PLAN KEYNOTES: EXISTING CARPET TO BE CLEANED. NEW ELECTRICAL PANEL LOCATION. NEW BUILDING STANDARD DOORS AND HARDWARE NEW PAINT THROUGHOUT, AS INDICATED. ALL WALLS P-1 UNLESS NOTED. DEMO EXISTING WALLS AND DOOR. DEMO EXISTING DOOR AND INFILL AT EXISTING OPENING - MATCH EXISTING MTL. STUD/ GWB WALL ASSEMBLY. REUSE EXISTING FURNITURE - SEE FURNITURE PLAN FOR LAYOUT. SAWCUT FOR POWER TO CONFERENCE TABLE FROM COLUMN. COORDINATE EXACT LOCATION WITH TENANT. PROVIDE NEW 2" CONDUIT TO SDC -42. CONFIRM EXACT REQUIREMENTS WITH TENANT. DEMO EXISTING WALL AND DOOR PROVIDE NEW TRANSITION STRIP AT EDGE OF CARPET. RELOCATE EXISTING FURNITURE THROUGHOUT AND SALVAGE FOR REUSE IN SCH TENANT IMPROVEMENT. REMOVE SIDE LITE AND INFILL TO MATCH EXISTING WALL. EXISTING CARPET TO REMAIN. MAINTAIN CLEARANCE TO PROVIDE ACCESS TO UTILIDOOR. PROVIDE 8" METAL STRAPPING AS NEEDED TO SUPPORT TENANT'S WALL MOUNTED MONITORS. FINISH LEGEND RB -1 RUBBER BASE MANUFACTURER: JOHNSONITE PRODUCT: TRADITIONAL TOE, 41/2" COLOR NUMBER: 63 COLOR NAME: BURNT UMBER CPT -1 CARPET MANUFACTURER: PRODUCT: COLOR NUMBER: COLOR NAME: MILLIKEN COLOR FIELD COL 170-154 CLOUDBURST REMARKS: PLANK CPT -2 CARPET MANUFACTURER: MILLIKEN PRODUCT: COLOR FIELD COLOR NUMBER: COL 170 COLOR NAME: BLUE HEAVEN REMARKS: PLANK DEMOLITION LEGEND: P-1 PAINT MANUFACTURER: COLOR NUMBER: COLOR NAME: FINISH: P-2 PAINT MANUFACTURER: COLOR NUMBER: COLOR NAME: FINISH: P-3 PAINT MANUFACTURER: COLOR NUMBER: COLOR NAME: FINISH: PAINT MANUFACTURER: COLOR NUMBER: COLOR NAME: FINISH: NEW CONSTRUCTION (SHOWN SOLID) EXISTING TO REMAIN (SHOWN SHADED) EXISTING TO BE DEMOLISHED L / (SHOWN DASHED) 41;e4.#44 AREA NOT iN SCOPE. SHERIN WILLIAMS SW7100 ARCADE WHITE EGGSHELL SHERIN WILLIAMS • SW7024 FUNCTIONAL GRAY. - EGGSHELL SHERIN WILLIAMS SW6237 DARK KNIGHT EGGSHELL SHERIN WILLIAMS SW6917 NERVY HUE EGGSHELL REVIEWED CODE COMPLIANCE APPROVED AUG 0 9 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA- JUL 0 9 2018 PERMIT CENTER SAB Architecture 12201 Tukwila Int' Blvd - 4th Floor Seattle, WA 98168 206.281.8700 sabey.com l'Ackti9 SEATTLE CHILDRENS HOSPITAL OFFICE Ti INTERGATE.EAST, BUILDING 5 3355 S 120TH PLACE TUKWILA, WA 98168 MARK I DATE I DESCRIPTION PROGRESS DATE: 07/09/18 DRAWN BY: AK CHECKED BY: TS APPROVED BY: KA PROJECT NO: Project Number All drawings and written material appearing herein constitute the original and unpublished work of the Sabey Corporation and the same may not be duplicated, used or disclosed. - without the written consent of the Sabey Corporation. CONSTRUCTION PLAN Aff=101 •1 F D B A 2 3 4 5 6 7 8 9 10 1 HI 111 LI •••••••••••••••••••••••••••*••• I• AC —1 Jt. •IE = El 1,,•••••••,••••••••• 11 *I ,T = •1 I ir 41E __I 4IC 111 low ....0112.1111 u FIRST FLOOR REFLECTED CEILING PLAN 118 = 1-0" RCP NOTES:• 1. REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS. 2. UON, ALL CEILINGS TO REMAIN. 3. NOT USED. 4. NOT USED. 5. EXIT SIGNS NOTED FOR REFERENCE ON LIFE SAEFTY SHEET. 6. NOT USED. 7. MECHANICAL SYSTEM IS BIDDER -DESIGNED. SUBMIT PLANS TO ARCHITECT FOR COORDINATION OF CEILING DEVICE LOCATIONS. 8. SPRINKLER QUANTITY AND LOCATIONS TO BE BIDDER -DESIGNED. SUBMIT PLANS TO ARCHITECT FOR COORDINATION OF CEILING DEVICE LOCATIONS. 9. ARCHITECTURAL REFLECTED CEILING PLANS INDICATE TYPE AND LOCATION OF LIGHT FIXTURES REFER TO DESIGN BUILD ELECTRICAL DRAWINGS AND DESIGN BUILD LIFE SAFETY FOR COMPLETE REFLECTED CEILING PLAN DESIGN. 10. LIGHT SWITCHES ARE SHOWN FOR LOCATION AND DESIGN INTENT ONLY. REFER TO ELECTRICAL DESIGN BUILD FOR SPECIFIC LOCATION AND SWITCHING DIAGRAMS. 11. UNLESS NOTED OTHERWISE, MULTIPLE SWITCH'S IN A SINGLE LOCATION SHALL BE GANGED IN A SINGLE BOX AND COVERED WITH A SINGLE COVERPLATE, 12. CLEAN, REPAIR OR REPLACE AS REQUIRED ALL EXISTING SUSPENDED CEILING GRID AND TILES EXISTING TO REMAIN. 13. HVAC CONTRACTOR TO CLEAN ALL EXISTING SUPPLY/RETURN GRILLS PRIOR TO COMPLETION OF PROJECT. 14. ELECTRICAL SUB -CONTRACTOR IS RESPONSIBLE FOR CONFIRMING THE COUNTS OF EXISTING FIXTURES. RCP KEY NOTES: VERIFY AND RELOCATE HVAC SYSTEM, SPRINKLERS AND LIFE SAFETY AS NEEDED PROVIDE NEW SUSPENDED LED LIGHT FIXTURE: CLAREO Q, FIXTURE AT 8AFF VERIFY LIGHT SWITCHING AS NEEDED REMOVE AND RELOCATE ALL EXISTING LIGHTING AS NEEDED RCP LEGND: u 1 1 NEW 314" X 4' SUSPENDED LED LIGHT FIXTURE, CLAREO Q EXISTING 2 X 12 PENDANT LIGHT FIXTURE TO BE RELOCATED OR REMOVED EXISTING 2 X 12 PENDANT LIGHT FIXTURE TO REMAIN 2 X 12 PENDANT LIGHT FIXTURE (RELOCATED) EXISTING 2 X 4 LIGHT FIXTURE TO BE RELOCATED OR REMOVED EXISTING 2 X 4 LIGHT FIXTURE TO REMAIN 2 X 4 LIGHT FIXTURE (RELOCATED) SWITCH 2,0 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 09 2016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 09 2018 PERMIT CENTER SA -B Architecture 12201 Tukwila Int' Blvd - 4th Floor Seattle, WA 98168 206.281.8700 sabey.com 6194 REGISTERED ARCHITECT SARA M. ANDERSON STATE OF WASHINGTON SEATTLE • CHILDREN'S HOSPITAL OFFICE TI INTERGATE.EAST, BUILDING 5 3355 S 120TH PLACE TUKWILA, WA 98168 MARK I DATE I DESCRIPTION PROGRESS DATE: 07/09/18 DRAWN BY: AK CHECKED BY: TS APPROVED BY: • KA PROJECT NO: Project Number All drawings and written material appearing herein constitute the original and unpublished work of the Sabey Corporation and the same may not be duplicated, used or disclosed without the written consent of the Sabey Corporation. REFLECTED CEILING PLAN. A=102 • 'is SAB EY Architecture POWER AND DATA LEGEND: DUPLEX DATA OUTLET DUPLEX ELECTRICAL OUTLET DUPLEX DEDICATED OUTLET DUPLEX DEDICATED OUTLET, ISOLATED GROUND FOURPLEX ELECTRICAL OUTLET CONTROLLED DUPLEX ELECTRICAL OUTLET 12201 Tukwila Int' Blvd - 4th Floor Seattle, WA 98168 206.281.8700 sabey.com (PC CONTROLLED DUPLEX DEDICATED OUTLET CONTROLLED FOURPLEX ELECTRICAL OUTLET ® FLOOR BOX WITH FOURPLEX ELECTRICAL OUTLET FLOOR BOX WITH FOURPLEX ELECTRICAL OUTLET AND DATA DUPLEX POWER AND DATA PLAN NOTES: 1. CONTRACTOR TO LOCATE ALL POWER AND DATA OUTLET LOCATIONS. COORDINATE EXACT LOCATION WITH TENANT. 2. PROVIDE CODE MINIMUM OUTLETS IN CORRIDORS. 3. FOR TYPICAL DEVICE MOUNTING HEIGHTS, SEE 3 / A-601 POWER AND DATA KEYNOTES: PROVIDE NEW DATA AND POWER OUTLETS THROUGHOUT PROVIDE NEW POWER/ DATA POLES. COORDINATE EXACT LOCATION WITH TENANT. NEW IDE RACK PROVIDED BY TENANT. COORDINATE ELECTRICAL REQUIREMENTS WITH TENANT. PROVIDE NEW FLOOR BOX IN THE CONFERENCE ROOM NEW ELECTRICAL PANEL NEW CARD READER INTERGATE.EAST, BUILDING 5 3355 S 120TH PLACE TUKWILA, WA 98168 / • / /;j �/ / / FIRST FLOOR POWER AND DATA PLAN 1 118,, 1,_0 )20 RECEIVED CITY OF TUKWILA JUL 0 9 2018 PERMIT CENTER MARK I DATE I DESCRIPTION PROGRESS DATE: 07/09/18 DRAWN BY: AK CHECKED BY: TS APPROVED BY: ' KA PROJECT NO: Project Number All drawings and written material appearing herein constitute the original and unpublished work of the Sabey Corporation and the same may not be duplicated, used or disclosed without the written consent of the Sabey Corporation. POWER AND DATA PLAN A-1 03 : %iv 1 FURNITURE AND EQUIPMENT` NOTES: 1. THIS PLAN IS FOR INFORMATION ONLY. FURNITURE AND EQUIPMENT KEYNOTES: OREUSE EXISTING FURNITURE. COORDINATE WITH TENANT. OAREA FOR NOC FURNITURE. CONFERENCE TABLE AND CHAIRS PROVIDED BY TENANT FIRST FLOOR FURNITURE PLAN REVIEWED FOR CODE COMPLIANCE APPROVED City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA ShBEY Architecture 12201 Tukwila Int' Blvd - 4th Floor Seattle, WA 98168 206.281.8700 sabey.com SEATTLE CHILDREN'S HOSPITAL.. OFFICE TI INTERGATE.EAST, BUILDING 5 3355 S 120TH PLACE TUKWILA, WA 98168 MARK I DATE I DESCRIPTION PROGRESS DATE: 07/09/18 DRAWN BY: CHECKED BY: APPROVED BY: AK TS KA PROJECT NO: Project Number All drawings and written material appearing herein constitute the original and unpublished work of the Sabey Corporation and the same may not be duplicated, used or disclosed without the written consent of the Sabey Corporation. FURNITURE PLAN A-104 F B A 10' CV DOOR LEAF PARTITION -TYPE VARIES BEVEL AT LATCH EDGE HOLLOW METAL A FRAME HOLLOW METAL FRAME DOOR OPENING SCHEDULE OPENING DOOR FRAME DETAILS REMARKS NO ROOM NAME HDWE SET, SIZE W H FIRE RTG TYPE CONFIG FIN TYPE CONFIG FIN HEAD JAMB(S) SILL 1 OFFICE 01 3'-0 7'-0" HM F PAINT HM PAINT 2/A-601 1/ A-601 PROVIDE CARD READER 2 NOC 02 3'-0" 7'-0" HM F PAINT HM 1 PAINT 2/A-601 1/ A-601: 3 EXISTING SUITE 121 01 3'-0" 7' 0" HM F PAINT HM 1 PAINT 2/A-601 1/A-601' DOOR HARDWARE GROUPS HW01 1/2" PR BUTTS CORRIDOR LOCK W/ REMOVABLE CORES DOOR STOP DOOR SILENCERS NAME PLATES: LANDLORD STANDARD SIGN PLATES AT ADA REQUIRED HEIGHT DOOR PULLS TO BE ADA COMPLIANT - LANDLORD STANDARD HARDWARE HWO3 1/2" PR BUTTS PASSAGE LOCKSET DOOR STOP F (FLUSH) V1 (VISON LITE W/ TEMPERED GLASS) V2 (VISON LITE' NI TEMPERED GLASS) SF (MEDIUM STILE STOREFRONT) *ALL DOOR PULLS TO BE ADA COMPLIANT *ALL DOORS ALONG EXIT PATH TO RECEIVE PANIC HARDWARE DOOR CONFIGURATION LEGEND FRAME CONFIGURATION LEGEND CV DOOR LEAF PARTITION-TYPE VARIES HOLLOW METAL FRAME HOLLOW METAL FRAME DOOR HEAD WALL END OR EDGE (WHERE OCCURS) DOOR FRAME OR WINDOW FRAME FIRE ALARM THERMOSTAT OR TEMPERATURE SENSOR NOTES: 1. USE THIS DETAIL TO LOCATE DEVICES THAT ARE INDICATED ON THE DRAWINGS BUT NOT LOCATED BY DIMENSION, OR TO LOCATE REQUIRED DEVICES THAT ARE NOT INDICATED ON THE DRAWING. 2. ALIGN MULTIPLE DEVICES HORIZONTALLY ANDIOR VERTICALLY AS DETAILED. WALL SEGMENT 2'-0" WIDE OR LESS I-� WALL END OR EDGE (WHERE OCCURS) TELEPHONES, DOOR SWITCHES, DOOR CONTROLLERS, FIRE ALARM PULL SWITCHES, LIGHT SWITCHES AND SIMILAR ITEMS (THE INTENT IS TO ALIGN TOPS OF ALL ITEMS WHILE ALLOWING ALL OPERABLE PARTS TO BE LESS THAN 4'-0" AFF) ELECTRICALRECEPTACLES- SINGLE, GANGED, OR SEPARATED BY 2" 3. ITEMS OTHER THAN ELECTRICAL RECEPTACLES SHALL BE MOUNTED NEAR DOORWAYS OR INTERSECTING WALLS AS DETAILED SO AS NOT TO INTERFERE WITH THE PLACEMENT OF ART OR FURNITURE -- EXCEPT THAT WHERE THE WALL SEGMENT IS LESS THAN 2'-0" WIDE, CENTER THE DEVICES AS DETAILED. WINDOW, DC OR OR "FEATURE" THAT SEPARATES JVALL` INTO SEW E \ITS ODEVICE MOUNTING GUIDELINES112"1'0 0 REVIEWED FOR CODE COMPLIANCE APPROVED City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 0 9 2018 PERMIT CENTER SAB Architecture 12201 Tukwila Int' Blvd - 4th Floor Seattle, WA 98168 206.281.8700 sabey.com SEATTLE CHILDREN'S. HOSPITAL OFFICE TI INTERGATE.EAST, BUILDING 5 3355 S 120TH PLACE TUKWILA, WA 98168 MARK I DATE I DESCRIPTION PROGRESS DATE: • 07/09/18 DRAWN BY: CHECKED BY: APPROVED BY: AK TS KA PROJECT NO: Project Number All drawings and written material appearing herein constitute the original and unpublished work of the Sabey Corporation and the same may not be duplicated, used or disclosed without the written consent of the Sabey Corporation. DOOR, DEVICE MOUNTING SCHEDULE AND DETAILS. A-60.1 10 J FRAMING, INSULATION AND FINISH MATERIALS (OR MASONRY) TO DECK ABOVE L_J NON -FIRE RATED FULL -HEIGHT PARTITION FRAMING, INSULATION, AND FINISH MATERIALS TO UNDERSIDE OF CEILING .A-801 NON -FIRE RATED PARTITION BRACED AT CEILING PARTITION/WALL CONFIGURATION NO SCALE 5/8" GYPSUM BOARD EACH SIDE METAL STUDS INSULATION IF NOTED 21/2" METAL STUDS 3 5/8" METAL STUDS 6" METAL STUDS PARTITION 3" =1'-0" FP aF II ®U THE PARTITION -TYPE DESIGNATION OR WALL -TYPE DESIGNATION ISA THREE -UNIT CODE THAT INDICATES THE CONFIGURATION, CONSTRUCTION AND INSULATION OF THE PARTITION AS FOLLOWS: INSULATION (PER THIS DETAIL, BELOW) CONSTRUCTION OF PARTITION/WALL VERTICAL CONFIGURATION OF PARTITION/WALL PARTITIONMIALL SYMBOLOGY INSULATIDN DESIGNATION NO INSULATION BATT ACOUSTICAL INSULATION BATT THERMAL INSULATION NOTES: 1. SEE SPECIFICATION FOR STUD SPACING AND GAGE. 2. WHERE FIRE AND/OR SOUND RATINGS ARE INDICATED, THE GYPSUM BOARD REQUIRED SHALL BE CONTINUOUS BEHIND ABUTTING NONRATED PARTITIONS SO THAT FIRE ANC/OR ACOUSTIC PERFORMANCE IS NOT COMPROMISED. P3 PART sk TYPE LEGEND NO S METAL STUDS (PER ICC ES REPORT ESR -3064P),. MAXIMUM HEIGHT 20'-0" - FINISH MATERIALS VARY (MAXIMUM WEIGHT EQUAL TO 2 LAYERS GYPSUM BOARD EACH SIDE PLUS APPLIED FINISHES) FASTENERS: AT PLYWOOD FLOOR (MINIMUM 3/4" CDX): PROVIDE (2) NO 8 X 1" WOOD SCREWS AT 24" MAXIMUM OC STAGGERED FOR 1 LAYER GYPSUM BOARD EACH SIDE, 16" MAXIMIM OC STAGGERED FOR 2 LAYERS GYPSUM BOARD EACH SIDE AT CIP CONCRETE AND POST -TENSIONED CONCRETE FLOOR: PROVIDE HILTI X -U. 0.157" DIAMETER POWDER -ACTUATED FASTENERS, EMBED 3/4" PER ESR -2269. 24" MAXIMUM OC STAGGERED FOR 1 LAYER GYPSUM BOARD EACH SIDE, 16" MAXIMUM OC STAGGERED FOR 2 LAYERS GYPSUM BOARD EACH SIDE , PTN-TO-FLR CONNECTION FOR SEISMIC SITUATIONS 3" =1'-0" FLUTED METAL DECK (20 GAGE MINIMUM) WITH OR WITHOUT CONCRETE. TYPICAL THROUGHOUT THIS DETAIL GENERAL NOTES: 20 GAGE MINIMUM DEEP LEG TRACK OR SLOTTED TRACK TO ALLOW 3/4" DEFLECTION. MAINTAIN DEFLECTION CAPACITY AND FIRE -RATING AT ALL STRUCTURAL MEMBERS STUDS CUT 3/4" SHORT TO ALLOW 3/4" DEFLECTION AT TOP OF FINISH MATERIALS (WHERE OCCURS) PROVIDE 3/4" CLEAR SPACE TO ALLOW 3/4" DEFLECTION. DO NOT SCREW FINISH MATERIALS INTO TOP TRACK - FASTEN INTO STUDS ONLY APPLY OR PATCH FIREPROOFING (WHERE FIREPROOFING IS REQUIRED) AFTER INSTALLATION OF TRACK OR STRAPS AT PARTITIONS WITH ACOUSTICAL INSULATION, INSTALL GYPSUM BOARD 2" SHORT TO ACCOMMODATE LARGER ACOUSTICAL SEALANT JOINT NEEDED TO ACHIEVE 3/4" DEFLECTION ACOUSTICAL SEALANT AND BOND BREAKER TAPE CASING BEAD, TYP ACOUSTICAL PARTITION, TYP SEISMIC DESIGN CATEGORYAAND B: STEEL -ONLY DECK: NO 8 SCREWS AT 16" OC OR STEEL AND CONCRETE DECK: HILTI X -U 0.157" DIAMETER POWDER -ACTUATED FMENERS AT. 24" OC, EMBED 314" PER ESR -2269 SEISMIC DESIGN CATEGORY C, D, E, AND F: STEEL -ONLY DECK: NO 10 SCREWS AT 12" OC' OR STEEL AND CONCRETE DECK: HILTI X -U 0.157" DIAMETER POWDER -ACTUATED FASTENERS AT 18" OC, EMBED 3/4" PER ESR -2269 NON -ACOUSTICAL PARTITION, TYP OPARTITION PERPENDICULAR TO FLUTES (B) PARTITION OFFSET AND PARALLEL TO FLUTES CASING BEAD WHERE EXPOSED TO VIEW, TYPICAL 4" WIDE PLATE (20 GAGE MINIMUM) AT 48" MAXIMUM OC, WHERE NECESSARY FOR PARTITION ATTACHMENT FASTEN TRACK TO PLATE WITH (3) NO 8 SCREWS AT 48" MAXIMUM OC FASTEN PLATE TO STEEL -ONLY DECK WITH (2) NO 8 SCREWS EACH END OF PLATE OR TO STEEL AND CONCRETE DECK WITH (2) HILTI X -U 0.157" DIAMETER POWDER -ACTUATED FASTENERS, EMBED 3/4", MIN 4" SPACING PER ESR -2269 PARTITION BETWEEN PARALLEL FLUTES INTERSECTION OF NON RATED PARTITIONS WITH FLUTED METAL DECK ABOVE 4 BOTTCM OF STRUCTURE PROUDE ENCAPSULATED ACOUSTICAL BATT EXTENDING 24" EACH SIDE OF PARTITION. 1 /4" PP416 - 2"X2"X12" MIN. LEG AT STRUCTURE ATTACH IN/ (2) 1/41'0 TITEN HD SCREW OR (2) 1/4"o EXPANSION BOLTS. PROVIDE 1-5/8" MIN. EMBEDMENT. Ae) PLENUM HEIGHT OF 5-0" OR LESS 2 1/2"x25 GA METAL STUD BRACING 0 8'-0" OC TO STRUCTURE DIRECTION ALTERNATE. PARTITIONS PERPENDICULAR TO PARTITION ACT AS BRACE PLENUM OF 5'-0" TO 10'-0" SHALL USE NESTED OR BACK TO BACK 3-1/2".25 GA. STEEL STUDS. ABOVE 1O'-0" OR PLENUM. CONTACT ARCHITECT FOR ADDMONAL INFORMATION. MAX PARTITION WEIGHT 15Ibs./P.S.F. SUSPENDED CEILING AS SCHEDULED 3/8" CONT. FOAM SOUND ISOLATION TAPE TAPEABLE MET. TOP TRACK ATTACHED TO BRACING W/2 SELF -TAPPING SM. SCREWS ® 48"oc, AND 3/4" PIPE SLEEVES PROVIDE BATT INSULATION IN CAVITY. 2 1/2" X.25 GA (18 MILS) METAL STUDS ® 24" OC, TO 10'-7" MAX.. HEIGHT. NOTE: CEILING IN AREAS OF THIS DETAIL ARE. 8'-3". 1 LAYER 5/8" TYPE "X" GYP. BD. EA. SIDE OF METAL STUDS ATTACHED W/ #6 SCREWS CO 12" OC MAX. POWDER DRIVEN FASTENER 0 24" OC METAL RUNNER TRACK SEALANT CONCRETE SLAB NON -RATED FLOOR TO CEILING PARTITION 3" = 1-0" CbRRE TION L7R#...�. ' JUL 31 1018 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 9 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA. Dl8- ozoj Sri Architecture 12201 Tukwila Int' Blvd - 4th Floor Seattle, WA 98168 206.281.8700 sabey.com 6194 RIICGISTERED ARCHITECT t • RANA M. ANDERSON STATE OF ION SEATTLE CHILDREN'S HOSPITAL OFFICE TI INTERGATE.EAST, BUILDING 5 3355 S 120TH PLACE TUKWILA, WA 98168 1 . 07/30/18 Permit Revisions MARK .j DATE i DESCRIPTION PROGRESS DATE: 07/30/18 DRAWN BY: CHECKED BY: APPROVED BY: PROJECT NO: AK TS KA Project Number All drawings and written material appearing herein constitute the original and unpublished work of the Sabey Corporation and the same may not be duplicated, used or disclosed without the written consent of the Sabey Corporation. PARTITION TYPES A-801