Loading...
HomeMy WebLinkAboutPermit D18-0225 - L & R SERVICES - RETAINING WALL REPLACEMENTL & R SERVICES 4712 S 134T" PL D18-0225 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 2616600071 4712 S 134TH PL L & R SERVICES DEVELOPMENT PERMIT Permit Number: D18-0225 Issue Date: 8/23/2018 Permit Expires On: 2/19/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: SCHWEIGER ERIC M 29850 148TH AVE SE , KENT, WA, 98042 ERIC MOE 12805 SHOREWOOD DR SW , BURIEN, WA, 98146 JEM CONTRACTORS INC 12805 SHOREWOOD DR SW , BURIEN, WA, 98146 JEMCOI*984CF ERIC SCHWEIGER Address: 29850 148TH AVE SE , KENT, WA, Phone: (425) 864-0452 Phone: (425) 864-0718 Expiration Date: 2/11/2020 DESCRIPTION OF WORK: REPLACE APPROX 50' OF EXISTING RETAINING WALL. EXISTING CONCRETE RUBBLE WALL HAS FAILED. INSTALL NEW ENGINEERED ECOLOGY BLOCK WALL. Project Valuation: $34,000.00 Type of Fire Protection: Sprinklers: NO Fire Alarm: NO Type of Construction: Electrical Service Provided by: TUKWILA Fees Collected: $1,304.94 Occupancy per IBC: U Water District: 125 Sewer District: VALLEY VIEW,TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No Permit Center Authorized Signature: Date: aV)-3 YO I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permjt ¢n gree to the conditions attached to this permit. Signature: Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 6: Subgrade preparation including drainage, excavation, compaction, and fill requirements shall conform strictly with the recommendations given in the soils report. Special inspection is required. 7: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 8: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 9: Masonry construction shall be special inspected. 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0201 FOOTING 0202 FOOTING DRAINS 0200 FOUNDATION WALL 4022 SI -MASONRY 4035 SI -SOILS CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. Project No. Date Application Accepted: 1 Date Application Expires: 1 12..0. (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 4712 South 134th Street Tukwila wa Tenant Name: L&R Services King Co Assessor's Tax No.: 261660-0071 Suite Number: New Tenant: PROPERTY OWNER Name: Eric Moe Name: Eric Schweiger Address: 12805 Shorewood Dr SW Address: 29850 148th Ave SE City: Burien State: Wa City: Kent State: Wa Zip: CONTACT PERSON — person receiving all project communication Name: Eric Moe Address: 12805 Shorewood Dr SW Address: 12805 Shorewood Dr SW Phone: (425) 864-0452 Fax: City: Burien State: Wa Zip: 98146 Phone: (425) 864-0452 Fax: City: Woodinville State: Wa Email: eric@jemcontractors.com Phone: (425) 488-0599 Fax: GENERAL CONTRACTOR INFORMATION Company Name: JEM Contractors Address: 12805 Shorewood Dr SW City: Burien State: WA Zip: 98146 Phone: (425) 864-0452 Fax: Contr Reg No.: CCJEMCOI*984CF Exp Date: 02/11/2020 Tukwila Business License No.: H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-1I.docx Revised: August 2011 bh Floor: ❑ Yes ARCHITECT OF RECORD Name: Fel t✓ cciv 4 e l () a_ Company Name: Robinson Company Name: Engineer Name: Barbara Gallagher Architect Name: City: Woodinville State: Wa Address: Phone: (425) 488-0599 Fax: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Name: Fel t✓ cciv 4 e l () a_ Company Name: Robinson City: KQ. State: , , a_ Zip: Engineer Name: Barbara Gallagher Address: 17625 130Th Ave NE Suite 102 City: Woodinville State: Wa zip: 98072 Phone: (425) 488-0599 Fax: Email: bgallagher@robinson-noble.com LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Fel t✓ cciv 4 e l () a_ Addressii 85-6 A /v,( SC- City: KQ. State: , , a_ Zip: Page 1 of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 34,000 Existing Building Valuation: $ 659,000 Describe the scope of work (please provide detailed information): Replace approximately 50 feet of existing retaining wall. Existing concrete rubble wall has failed. Install new engineered ecology block wall Will there be new rack storage? ❑ Yes .. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Floor area of accessory dwelling: Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes II No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm VI None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Fonns-Applications On Line\2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC Is' Floor 7,500 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Floor area of accessory dwelling: Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes II No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm VI None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Fonns-Applications On Line\2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFORMATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District m ...Tukwila ❑ ...Water District #125 ❑ ...Water Availability Provided Sewer District m ...Tukwila ❑ ...Sewer Use Certificate ❑ .. Highline ❑ ... Valley View ❑ .. Renton ❑ ... Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): VI ...Civil Plans (Maximum Paper Size — 22" x 34") 0 ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): 0 ...Right-of-way Use - Nonprofit for less than 72 hours m ...Right-of-way Use - No Disturbance 0 ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ...Total Cut 80 cubic yards ❑ ...Total Fill 55 cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ . ❑. ❑. ❑ . z ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑ ...Traffic Impact Analysis ❑ ... Hold Harmless — (SAO) 0... Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours 0 .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage . Abandon Septic Tank . Curb Cut . Pavement Cut . Looped Fire Line O ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public 0 ❑ ...Water Main Extension Public ❑ O .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding WO # WO # WO # ❑ ...Deduct Water Meter Size Private ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Line O ...Water 0 ...Sewer Monthly Service Billing to: Name: Number of Public Fire Hydrant(s) 0 ...Sewage Treatment Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:Wpplications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Date: 7 14/ t Print Name: Eric Moe Day Telephone: (206) 246-1204 Mailing Address: 12805 Shorewood Dr SW H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Burien Wa 98146 City State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ( ACCOUNT I QUANTITY PAID $1,304.94 D18-0225 Address: 4712 S 134TH PL Apn: 2616600071 $1,304.94 DEVELOPMENT $1,267.29 PERMIT FEE R000.322.100.00.00 0.00 $752.90 PLAN CHECK FEE R000.345.830.00.00 0.00 $489.39 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $25.00 TECHNOLOGY FEE $37.65 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R15011 R000.322.900.04.00 0.00 $37.65 $1,304.94 Date Paid: Tuesday, July 24, 2018 Paid By: JEM CONTRACTORS Pay Method: CHECK 11990 Printed: Tuesday, July 24, 2018 12:03 PM 1 of 1 CRWSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 OM -0225 Project: p L R Se v'icitS Type of Inspection Foo+ 4...)\ --Ai ►t1. S Address: % llg 47/2 S. /�y Date Called: �, Special Instructions: Date Wanted: �' 9-9-2- I( a.m� p. . Requester: Phone No: Approved per applicable codes. COMMENTS: jam' - br,4/K's Corrections required prior to approval. %5°76, L.tJFK.E /S 24hts4z1 Aica jaew12,A.Avic Inspector: --/....“21) Date:9 _ L'- c/V REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. SEPA ATL PERMIT REQUIRED FOR: ClKlachanical Iectrical Cif/Plumbing c 'Gas Piping City of Tukwila BuluDING DIVISION N REVISIONS No changes shall he made to the scope of work witho+;t prior approval of T,ily :,ila f3u ding Division NOTE: I;cviscr;:, will require a new plan submittal and may include additional plan review fees. --411110 ef I w� • I, I •1 rLANNING APPROVgb/ No changes can be madeto1he plans without approval from Planning Division of D Approved By:_ta rate: FILE COPY Permit No. b [g Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Cop: j d conditions is acknowledged: By: Data: City of Tukwila BUILDING DIVISION 1 0'-0" , s 777- 7 o'A Ultabock Retaining Wall Property Line Drain Pipe No know easements REVIEWED FOR CODE COMPLIANCE APPROVED \ 12k-TCity of Tukwila BUILDING DIVISION AUG 02 2018 CBT EC�' ED F -ND JUL 2018X RMIT CEN •kR SPECIFICATIONS FOR GRAVITY ULTRABLOCK WALL General: 1. The contractor shall have an approved set of plans and specifications on site at all times during the construction of the wall. The wall layout is the responsibility of the contractor. 2. A professional engineer or representative should observe and monitor the construction of the wall. 3 Blocks shall consist of 2.5'x2.5'x5.0' UltraBlocks or equivalent. 4. Blocks shall be placed in accordance with UltraBlock wall specifications and guidelines. Subgrade Preparation: 1. The ground should be prepared by removing surficial unsuitable soil, exposing medium dense or better inorganic, native soils as approved by the geotechnical engineer. 2 The excavation shall be cleaned of all excess material and protected, as necessary, from construction traffic to maintain the integrity of the subgrade. 3 The base of the excavation should be deep enough to satisfy the 5 -foot setback from slope face as shown on the section. Minimum embedment is 12 Inches, Fill Placement: 1 Structural fill should have parameters equal to or better than those stated for the reinforced wall fill with less than 20% passing the number 200 sieve. The geotechnical engineer may allow a higher silt content based on review of the wall design and proposed fill parameters. 2. Soil density tests should be performed as designated by the geotechnical engineer. 3. Fill soils in the wall area shall be compacted to at least 95% of Maximum Dry Density IMDD) as determined by ASTM D- 1557 Maximum Dry Density. 4 The soil shall be placed in relatively uniform horizontal lifts not exceeding 10 or 12 inches in thickness. The lift thickness shall not exceed the manufacturer's recommended depth for the compactive device used on the project. Drainage: 1. A drainage system shall be installed as shown in the typical cross-section detail. The wall drain shall consist of sand and gravel and a 4 -inch perforated pipe place behind the base of the block facing. The sand and gravel blanket should have a minimum width of 12 inches. The perforated pipe should be tightlined to an approved drainage at the low point of the wall. 2. Surface water shall not be allowed to pond in or near the reinforced fill zone during or after construction. Design Parameters: Retained Backfill 31 deg 120 PCF Foundation Soil 40 deg 135 PCF External Stability: Minimum Factor of Safety against Base Sliding = 1.5 Minimum Factor of Safety against Overturning = 2.0 Minimum Factor of Safety against Bearing = 3.0 Inspection: The construction shall be periodically inspected under the direction of an engineer registered in the state of Washington with experience in the design of retaining walls. ECOLOGY BLOCK LAYOUTS FOR ON-SITE RETAINING WALLS 7.5' 1 10' TYPICAL GRAVITY ULTRABLOCK WALL CROSS-SECTION (not to scale) FREE DRAINING SAND & GRAVEL CAP BLOCK (OPTIONAL) ULTRA BLOCK w OR EQUIVALENT z 0 rn uJ O 2 /LOW PERMEABILITY CAP UNDERLAIN BY MIRAFI 140N 3 1 12 1 12" (min) 5' (min) NATIVE UNDISTURBED SOIL OR STRUCTURAL FILL J EXISTING FILL 1=IIIII illl�'ll 4" PERFORATED PIPE REVIEWED FOR CODE COMPLIANCE APPROVED AUG 02 2010 Gity of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 2 4 2018 PERMIT CENTER Note: ROBINSON' NOBLE PM: BAG July 2018 3103-002A Figure 2 Gravity Ultrablock Wall Detail JEM Contractors: Sound Transit Schweiger Property u Project: Location: Designer: Date: Section: Design Method: Design Unit: U Itra Wa l I JEM Sound Transit Schweiger Property Tukwila BGallagher 7/18/2018 Section 3 AASHTO_LRFD 2012 Ultrabiock Seismic Acc: 0.440 SOIL PARAMETERS Retained Soil: Foundation Soil: Leveling Pad: GEOMETRY Design Height: Wall Batter/Tilt: Embedment: Leveling Pad Depth: Slope Angle: Slope Length: Slope Toe Offset: cp coh y 31 deg 0 psf 120 pcf 40 deg 0 psf 135 pcf 40 deg 0 psf 140 pcf Crushed Stone 7.40 ft 0.0/ 0.00 deg 0.00 ft 0.49 ft 18.5 deg 20.0 ft 0.O ft Live Load: 0 psf Live Load Offset: 0.00 ft Live Load Width: 0 ft Dead Load: 0 psf Dead Load Offset: 0.0 ft Dead Load Width: 0 ft Leveling Pad Width: 5.91 ft Toe Slope Angle: 26.50 Toe Slope Length: 4.99 Toe Slope Bench: 0.00 z to - o2 U' CO PERMIT CENTER Note: Calculations and quantities are for PRELIMINARY ANALYTICAL USE ONLY and MUST NOT be used for final design or construction without the independent review, verification, and approval by a qualified professional engineer. UltraWall 5.0.18138 Pana 1 2/7/2019 City of Tukwila Department of Community Development ERIC MOE 12805 SHOREWOOD DR SW BURIEN, WA 98146 RE: Permit No. D18-0225 L & R SERVICES 4712 S 134TH PL Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 3/3/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 3/3/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Jazzel Salzar Permit Technician File No: D18-0225 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 pPERMIT CORD COPY c PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0225 DATE: 07/24/18 PROJECT NAME: L & R SERVICES SITE ADDRESS: 4712 S 134TH ST X Original Plan Submittal Revision # before Permit Issued Revision # after Permit Issued Response to Correction Letter # DEPARTMENTS: Building Division /OM AP Public Works AM AM - 1 - Fire Prevention IEJ Structural Planning Division Permit Coordinator -31-0 1 PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: 07/26/18 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Corrections Required ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: DUE DATE: 08/23/18 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 JEM CONTRACTORS INC CWashington State Department of Labor & industries Home Espanol Contact Safety & Health Claims & Insurance Search L&I Page 1 of 2 A-7, index Help My L&1 Workplace Rights Trades & Licensing JEM CONTRACTORS INC Owner or tradesperson Principals MOE (MILES), JENNIFER TRACY, PRESIDENT MOE, ERIC CARL, VICE PRESIDENT SCHLEMLEIN, GARTH, AGENT SHINN, MIKE, SECRETARY (End: 04/27/2007) Doing business as JEM CONTRACTORS INC WA UBI No. 602 160 486 12805 SHOREWOOD DR SW BURIEN, WA 98146 425-864-0718 KING County Business type Corporation Governing persons ERIC CARL MOE JENNIFER TRACY MOE; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. JEMCOI*984CF Effective — expiration 02/06/2002— 02/11/2020 Bond ............... Hanover Insurance Company, The Bond account no. 1005580 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 05/15/2012 05/26/2012 Expiration date Until Canceled Insurance ............................ Ohio Security Ins Co $1,000,000.00 Policy no. BKS54805221 Received by L&I Effective date 05/23/2018 07/07/2018 Expiration date Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602160486&LIC=JEMCOI*984CF&SAW= 8/23/2018 JEM CONTRACTORS INC 0 07/07/2019 0 Insurance history. Savings ...._..............._.. No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&l Tax debts No L&l tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts L&I Account ID 878.329-01 Doing business as JEM CONTRACTORS INC Estimated workers reported Quarter 2 of Year 2018 "7 to 10 Workers" L&I account contact TO / JULIE SUR (360)902-4715 - Email: SURJ235@Ini.wa.gov Track this contractor 0 Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor .Strikes ................................. ................... No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 et Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602160486&LIC=JEMCOI*984CF&SAW= 8/23/2018