Loading...
HomeMy WebLinkAboutPermit D18-0252 - CRYSTAL RIDGE CONDOMINIUMS / BUILDING A - REROOFCRYSTAL RIDGE CONDOMINIUMS 15315 SUNWOOD BLVD BLDG A EXPIRED 02/20/19 D18-0252 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 1865200000 Permit Number: 15315 SUNWOOD BLVD BLDG A Project Name: CRYSTAL RIDGE CONDOMINIUMS Issue Date: Permit Expires On: D18-0252 8/24/2018 2/20/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: „ WA, ROBERT N JOHNSON 12863 NORTHUP WAY, BELLEVUE, WA, 98005 BLUE STAR ROOF & GUTTERS LLC 12863 NORTHUP WAY, BELLEVUE, WA, 98005 BLUESSR837CH CRYSTAL RIDGE CONDOMINIUMS 15315 SUNWOOD BLVD , TUKWILA, WA, 98188 Phone: (206) 920-1751 Phone: (425) 455-5881 Expiration Date: 2/8/2019 DESCRIPTION OF WORK: REPLACE OLD COMPOSITION ROOFING ON 14 GARAGES. REPLACE TORCH DOWN ROOFING WITH VERIFLEX PVC 80 MIL Project Valuation: $83,000.00 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $2,336.40 Occupancy per IBC: U Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: 01...)-214 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development ;;may and agree i tie conditions attached to this permit. Signat /f V % Date: Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: Prior to final inspection for this building permit, a copy of the roof membrane manufacturer's warranty certificate shall be provided to the building inspector. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0103 PRE-REROOF CITY OF TUKW1i4 Community Develop I, Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Per No. ES _ Project No. Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: AS—3 cj Tenant Name: ( , �� 1�Kiiing Co Assessor's Tax No.: ,rSuite Number: Floor: p-1.4..-Arrm New Tenant: ❑ Yes vt..No PROPERTY OWNER Name: n 4 ehleA R.,e'lirtc.�rooc0 Address: / /��. S�� ��3 City: 7:2( Otze j26 State:/1.C1ii). Zip. perI sd CONTACT PERSON — person receiving all project communication Name: eleeo /v ! ` Address: ;�ffi( 3 d .s, '"�_7 City: ue�%r-ter State: 641 Zip: 2ereas5 Address: /a s6.3 Contr Reg No.: uL v` S� Z i x3p Date: ti e w City: j ,., je_ State: Zip:,..cpad 5 Phone:0106 _ 5-2,0 ./7 x. Email: 1-ULr6F,4, 2%I ed . ,vh67,6„.) , L GENERAL CONTRACTOR INFORMATION Company Name:/��!,� . `�;.k _e/ Jw. Address: ;�ffi( 3 d .s, '"�_7 City: ue�%r-ter State: 641 Zip: 2ereas5 Phone: 4` / w v7 : Contr Reg No.: uL v` S� Z i x3p Date: ti e Tukwila Business License No.: 7 H:'Applications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh ARCHITECT OF RECORD Name: Company Name: `�) �/ / -„,z,,) Architect Name: 3 / Address: /�a� Q SCJ �fsr� State: (,<.,4 Zip:�r,- City: /44.160.4./4, City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Name: Company Name: `�) �/ / -„,z,,) Engineer Name: 3 / Address: /�a� Q SCJ �fsr� State: (,<.,4 Zip:�r,- City: /44.160.4./4, City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: `�) �/ / -„,z,,) Address/ 3 / (S ..rly,.e /�a� Q SCJ �fsr� State: (,<.,4 Zip:�r,- City: /44.160.4./4, Page 1 of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Existing Building Valuation: $ Valuation of Project (contractor's bid price): $ 2g/0-00 -%! Describe the scope of work (please provide detailed information): vv4 'vL pLe Will there be new rack storage? ❑ .... Yes ❑ ..No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm 0. .. None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes 0 No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms-Applications On Line \2012 Applications\Permit Application Revised - 2-7-I2.docx Revised: February 2012 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1' Floor 2nd Floor 3`d Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm 0. .. None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes 0 No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms-Applications On Line \2012 Applications\Permit Application Revised - 2-7-I2.docx Revised: February 2012 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. ,The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 Intemational Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OR AUTHOR )/AGENT: Signature: �i /� 1 Date: CV ��� P Print Name: 04 d f L je #NSD Day Telephone: A016 ! 2 v 17 r/ Mailing Address:/0V6 3 /,V /f U/D i)4 9/Oi S / / City State Zip H:Wpplications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 4 of 4 ' PUBLIC WORKS PERMIT INFORMATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila 0 ...Water District #125 ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ .. Sewer Use Certificate ❑ ...Valley View ❑ ...Sewer Availability Provided ❑... Highline ❑... Renton 0... Renton 0... Seattle Septic System: ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ .. Civil Plans (Maximum Paper Size — 22" x 34") ❑ .. Technical Information Report (Storm Drainage) ❑ .. Bond 0... Insurance 0... Easement(s) Proposed Activities (mark boxes that apply): ❑ .. Right-of-way Use - Nonprofit for less than 72 hours ❑ .. Right-of-way Use - No Disturbance ❑ .. Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way 0 ❑ .. Total Cut cubic yards ❑ .. Total Fill cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities ❑ .. Frontage Improvements ❑ .. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Permanent Water Meter Size (1) ❑ .. Temporary Water Meter Size (1) ❑ .. Water Only Meter Size ❑ . ❑. ❑ . 0... Geotechnical Report 0...Maintenance Agreement(s) ❑ .. Traffic Impact Analysis ❑ .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) 0...Right-of-way Use - Profit for less than 72 hours 0...Right-of-way Use — Potential Disturbance 0...Work in Flood Zone 0... Storm Drainage .. Abandon Septic Tank .. Curb Cut .. Pavement Cut . Looped Fire Line 0.. ❑ .. Sewer Main Extension Public 0 .. Water Main Extension Public 91 WO # WO # WO # Private 0 Private 0 ❑... Grease Interceptor 0... Channelization 0...Trench Excavation 0... Utility Undergrounding (2) " WO # (3) " WO # (2) " WO # (3) " WO # 0 .. Deduct Water Meter Size " FINANCE INFORMATION Fire Line Size at Property Line 0 .. Water 0 .. Sewer ❑ .. Sewage Treatment Monthly Service Billing to: Name: Number of Public Fire Hydrant(s) Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip H: Applications\Forms-Applications On Line\2012 Applications\Penmit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 3 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT I QUANTITY PermitTRAK PAID $2,336.40 D18-0252 Address: 15315 SUNWOOD BLVD BLDG A Apn: 1865200000 $2,336.40 DEVELOPMENT $2,268.42 PERMIT FEE R000.322.100.00.00 0.00 $1,359.65 PLAN CHECK FEE R000.345.830.00.00 0.00 $883.77 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $25.00 TECHNOLOGY FEE $67.98 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R15125 R000.322.900.04.00 0,00 $67.98 , $2,336.40 Date Paid: Thursday, August 09, 2018 Paid By: BLUE STAR ROOF & GUTTERS Pay Method: CHECK 1631 Printed: Thursday, August 09, 2018 11:36 AM 1 of 1 SYSTEMS No changes shaVheImad ile to thR 4G�AP, of work without P,r,or approval of Tui pita Guik,i g Division NOTE`rs:ti: .:.r, tai rare a new plan end may trate adational t rteview fees. FILE COPY Permit No. 11 g- 0 2— Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Fipy and conti • 1s is acknowledged: Data: I : City of Tukwila BUILDING DIVISION /SEPARATE PE MIT 1 F; =QUI; ED FOR: i211/44ponanical 'tcctrica) Itumbing s Piping C:./ of Tukwila Et,"' r"' ° DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED AUG 14 2018 Cityof Tukwila BUILING DIVISION RECEIVED CITY OF TUKWILA AUG 0 9 2018 PERMIT CENTER 4/ NMINA1'EDASPI1S.LiSHINGLE5 •,- AUG 0 9 2018 • INIESieggiliglielniESIgkanialsoq.,, BUILDING PRODUCTS FREDERICK PDF.js viewer 1 VERSIFLEX Page 1 of 16 REVIEWED -FOR CODE COMPLIANCE RECEIVED CITY OF TUKWIL„ AUG 0 9 2018 PERMIT CENTER 'Roofing O.Z52 https://www.versico.com/js/PDF/web/viewer.html?file=/h misc.ashx%3ftype%3dviewpdf... 8/3/2018 PDF.js viewer "ow VERSICO ROOFING SYSTEMS 401-44146, Page 2 of 16 r , BUILDING 03V13-D-4.ri AliW>01"r \roo https://www.versico.com/ js/PDF/web/viewer.html?file=/h_misc.ashx%3ftype%3dviewpdf... 8/3/2018 PDF.js viewer Page 3 of 16 ��I VERSIFLEX PVC ROOFING SYSTEMS Why Choose PVC? PVC (polyvinyl chloride) single -ply membranes have been around for nearly 50 years, since the first in Europe in the 1960s. Since then, PVC membranes have quickly gained popularity in the roofing it for the past 30 years have become recognized as a sustainable alternative for low -slope roofing s PVC is now Installed on thousands of rooftops across the world and is known for its durability and r damage caused by water, fire and puncture. WHY CHOOSE VERSIFLEX PV With decades of experience in the single -ply roofing Industry, Versico strives to provide the highest quality, longest -lasting and most efficient roofing products in the Industry. You can rest assured that Versico's VersiFlex PVC membranes will perform to the highest standards with a durability that Is backed by Industry- leading warranty coverage. Versico also offers the industry's broadest range of PVC products, so that you can find the Ideal solution for your rooftop. The VersiFlex line of products includes: • Polyester- and fiberglass -reinforced membranes for use on mechanically attached and fully adhered applications • Elvaloy° KEE HP -enhanced membranes for Increased chemical resistance • 10 -foot -wide membranes for fewer seams • Fleece -backed membranes for increased puncture resistance and durability Energy Efficiency & Sustainability As energy costs continue to rise. so does the need for energy-efficient roofing systems. Versico's white, hinhly raflactiva VarslFiax PVC mamhrnnas cnn With Inherently high reflectivity, white Versi membranes are ENERGY STAR° qualified, C Roof Rating Council (CRRC) rated, compll( California's Title 24 and can also contribut+ LEED° credit requirements. Strength & Durability Composed of three layers - a PVC polyme ply, a strong polyester or flberglass-relnforc scrim and a tough thermoplastic PVC -con top ply - VersiFlex PVC is specifically desigi long-term performance. Because of Its en! durability, VersiFlex PVC Is also highly resist( and chemicals Including acids, bases, rest and grease, offers Increased wind resistan has surpassed Factory Mutual's 1-90 wind u classification, one of the most stringent sta the Industry. VersiFlex also resists damage 1 caused by roof traffic and construction, er your rooftop remains In Ideal condition thr+ the construction process. Code Approvals With enhanced wind uplift resistance and •I1+/' n-le•I Y%+ d -.I- nrn,% .-%r; n+l IAC We're/Oro., 0'.IP" me https://www.versico.com/_js/PDF/web/viewer.html?file=/h misc.ashx%3ftype%3dviewpdf... 8/3/2018 PDF.js viewer significantly lower operating costs by reducing air- conditioning usage, minimizing the urban heat Island effect and also helping to slow the formation of smog -forming pollutants. Page 4 of 16 iviuiuw a 1.1 iu1tJt,ivnam.a, boimrl A r vI I is meet or exceed the requirements of ASTM VersiFlex membranes are UL and FM apprc meet the requirements of Miami -Dade an( Building Code. https://www.versico.com/_js/PDF/web/viewer.html?file=/h misc.ashx%3ftype%3dviewpdf... 8/3/2018 PDF.js viewer Page 5 of 16 FRS vs. Polyester Scrim Reinforcement PVC membranes with polyester or fiberglass reinforcement have both been used with great success in roofing over the past 40 years. Due to its greater tensile and tear strength, Polyester reinforced membrane can be used In either adhered or mechanically fastened systems, while fiberglass reinforced products are limited to adhered applications. Both reinforcements provide excellent dimensional stability, durability but only the polyester contributes to superior puncture, breaking, and tear resistance. Warranty Options 50 -mil 60 -mil 80 -mil 10 -Year X X Long -Term Protection Each detail of a VersiFlex PVC roofing system Is addressed by Verslco to ensure the long-term 1 mind customers crave. Due to the excellent lot dependability of Versico's VersiFlex PVC and K membranes, 5 -30 -year No Dollar Limit warrant is available and can be supplemented with ac puncture coverage. VersiFlex PVC and VersiFlex FRS PVC Membranes 15 -Year 20 -Year 25 -Year 30 -Year X X X 10 -Year X X VersiFlex-E KEE HP Membran 15 -Year X X 20 -Year 25 -Year X X X https://www.versico.com/,js/PDF/web/viewer.html?file=/h misc.ashx%3ftype%3dviewpdf... 8/3/2018 PDF.js viewer Page 6 of 16 https://www.versico.com/_js/PDF/web/viewer.html?file=/h misc.ashx%3ftype%3dviewpdf... 8/3/2018 PDF j s viewer Page 7 of 16 The Benefits of Elvaloy Historically PVC membranes have been formulated using liquid plasticizers that make the p more flexible. Over time these plasticizers can migrate out of the membrane, reducing flexibility effort to find a more stable plasticizer that also offers increased durability and permanence, as better Tong -term performance, the chemists at DuPont developed a Ketone Ethylene Este plasticizer they have branded Elvaloy. KEE, or Eivaioy, which has a high molecular weight mc extremely stable and durable even under the harshest conditions. Versico goes one step beyond KEE and uses the KEE HP made by DuPont. The KEE HP Is a "High Perforn KEE and Is an extension of the standard KEE. The "High Performance" KEE has a higher molecular and greatly increases chemical resistance, low temperature flexibility and weldability over the sk KEE. PVC membranes enhanced with Elvaloy KEE offer building owners a number of distinct adva over PVC membranes with traditional liquid plasticizers. The largest benefits include: Resistance to Migration Low-grade liquid plasticizers of the past were problematic, migrating from the membrane over time and reducing flexibility. Elvaloy KEE HP is a solid plasticizer with the highest molecular weight of any Elvaloy—it does not migrate from the membrane, keeping it weldable and pliable throughout a roof system's entire service life. High Performance, Even Under Duress Elvaloy KEE HP Is a durable plasticizer that roof's resistance to harmful chemicals and it can handle the heavy-duty challenges c rain, harsh chemicals, Industrial pollutants, and even Jet fuel. These chemicals can ex plasticizers out of standard PVC membrana to premature degradation. Elvaloy-enhani membranes are more resistant to the effec chemicals, making them the Ideal choice exposed to the harshest environments. Protection from the Elements For proven durability against severe weatr conditions, there's nothing like PVC memb enhanced with Elvaloy KEE HP. It remains fl' most extreme weather conditions and Its r( toughness provides Increased resistance tc and tearing. KEE HP -enhanced PVC also p enhanced protection against UV degradc Easy Repairs Because it remains more flexible than tradl plasticizers over time, Elvaloy KEE HP-enhar membranes are able to be re -welded with after installation if repairs need to be mad( Optimal Formulation In a study performed on PVC membrane € with Elvaloy KEE HP It was determined that direct correlation between the window of https://www.versico.com/_js/PDF/web/viewer.html?file=/h misc.ashx%3ftype%3dviewpdf... 8/3/2018 PDF.js viewer Page 8 of 16 of PVC and the amount of Elvaloy within tt Elvaloy content increases within~PVC mem window to produce a good, solid weld de Cost is also affected as the price of PVC rr dramatically Increases when excessive arr Elvaloy polymer are Incorporated Into the https://www.versico.com/_js/PDF/web/viewer.html?file=/h misc.ashx%3ftype%3dviewpdf... 8/3/2018 PDF j s viewer Page 9 of 16 Accessories Most rooftops have hundreds of penetrations. Flashing these obstructions can be time consuming and labor intensive, adding not only time but also cost to your roofing protects. Not to mention that these pipes, curbs and other penetrations can cause severe leakage problems if not flashed properly. Versico provides dozens of prefabricated, standard - order, in -stock accessories, as well as many custom - order accessories, to waterproof even the most difficult and unique penetrations. No matter what kind of Intricate detail is present on your rooftop, Versico has an accessory to meet your needs. All Versico PVC accessories are fabricated using the KEE HP formulation for reduced smoke during the welding process and enhanced performance at these critical transition areas. All Versico PVC accessories carry a CFA (C Fabricated Accessory) stamp of approval, know they are manufactured to the highe standards. Verslco's CFA -approved access save labor, time and installation cost whilk to maintain the watertight performance a VersiFlex PVC roofing system. Certified Fabricated Accessory https://www.versico.com/_js/PDF/web/viewer.html?file=/h misc.ashx%3ftype%3dviewpdf... 8/3/2018 PDF.js viewer Page 10 of 16 https://www.versico.com/js/PDF/web/viewer.html?file=/h misc.ashx%3ftype%3dviewpdf... 8/3/2018 PDF.js viewer VersiFlex Membranes Page 11 of 16 Versico offers a wider variety of PVC and KEE HP membranes than any other manufacture PVC and KEE HP membranes are Ideal for fully adhered and mechanically attached c and are available in a variety of thicknesses, ranging from 50 to 80 mils, and various color option white, gray and tan. VersiFlex PVC VersiFlex PVC is a three -layer polyester -reinforced membrane that is specially designed for long-term performance. Features and Benefits • Long-term resistance to solar UV, ozone and oxidation • Sustainable, recyclable and energy efficient; can contribute toward LEED° credit requirements • Wide window of weidabiiity provides easy installation VersiFlex FRS PVC VersiFlex FRS PVC utilizes a fiberglass -reinforced scrim that is fully encapsulated and designed only for fully adhered applications In all climates, especially those with extreme temperature fluctuations. Features and Benefits • Enhanced puncture resistance • Low water vapor permeance and water absorption • Excellent low temperature Impact resistance in cold climates VersiFlex E KEE HP Membrane with Elvaloy' VersiFlex-E KEE HP Is manufactured using DuPont"' Eivaloy KEE HP, a resin modifier that provides permanent flexibility, improved UV resistance and long-term weathering performance. Eivaloy also eliminates the need for a lacquer coating, which over time will weather away and lose its resistance to dirt and microbial growth. Enhanced strength and durability make VersiFlex-E KEE HP Ideal for applications in which the roofing membrane may be exposed to harsh chemicals and conditions such as acid rain, grease, air-conditioning coolants and intense sunlight. https://www.versico.com/js/PDF/web/viewer.html?file=/h misc.ashx%3ftype%3dviewpdf... 8/3/2018 PDF.js viewer Features and Benefits • Excellent long-term weldabllity • increased cold weather flexibility • Easier repairs, modifications and maintenance on roof systems Page 12 of 16 https://www.versico.com/j s/PDF/web/viewer.html?file=/h_misc.ashx%3ftype%3dviewpdf... 8/3/2018 PDF j s viewer Page 13 of 16 VersiFleeces FRS PVC VerslFleece FRS PVC Is reinforced with a fibE and enhanced with fleece, creating a very durable and versatile sheet that Is ideal for or new construction projects. Versico's VersiFlex PVC formulation delivers weatherability, flexibility and toughness, ar fiberglass reinforcing scrim provides additic dimensional stability to the sheet. In additk providing a built -In separation layer for roui decks or existing asphaltic -based roofing s' fleece backing enhances the membrane': resistance. https://www.versico.com/_js/PDF/web/viewer.html?file=/h misc.ashx%3ftype%3dviewpdf... 8/3/2018 PDF.js viewer Page 14 of 16 , Features and Benefits • Superior wind uplift resistance do to the between fleece and adhesive • Wide window of weldability • Fleece reinforcement adds toughness, c and enhanced puncture resistance https://www.versico.com/_j s/PDF/web/viewer.html?file=/h_misc.ashx%3ftype%3dviewpdf... 8/3/2018 PDF j s viewer Page 15 of 16 1 https://www.versico.com/_js/PDF/web/viewer.html?file=/h misc.ashx%3ftype%3dviewpdf... 8/3/2018 PDF.js viewer Page 16 of 16 semrio VERSICO ROOFING SYSTEMS A SINGLE SOURCE FOR SINGLE -PLY ROOFING 800.992.7663 • www.versico.com 02017 Versico. Prirded in U.S.A. Verslco, VersiRex, VersRleece and Ra Varsloo logo are registered lodernarks o Wake EVER( REPRINT REQUEST CODE: 802488 "VersiHex Brochure' 04 18.18 trademark owned by the US Government. UM is a regisfored trademark 01 the U S 0 https://www.versico.com/_js/PDF/web/viewer.html?file=/h misc.ashx%3ftype%3dviewpdf... 8/3/2018 1/2/2019 City of Tukwila Department of Community Development ROBERT N JOHNSON 12863 NORTHUP WAY BELLEVUE, WA 98005 RE: Permit No. D18-0252 CRYSTAL RIDGE CONDOMINIUMS 15315 SUNWOOD BLVD Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 2/20/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 2/20/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: D18-0252 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0252 DATE: 08/09/18 PROJECT NAME: CRYSTAL RIDGE CONDOMINIUMS SITE ADDRESS: 15315 SUNWOOD BLVD X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: AT 41,0 C -14- le Building Division I Public Works C A-ro\ /4k g,14--tg Fire Prevention Planning Division Structural ❑ Permit Coordinator n ■ PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 08/14/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09/11/18 Approved Corrections Required ❑ Approved with Conditions n Denied n [xi (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVI.EWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW ❑ Staff Initials: 12/18/2013 BLUE STAR ROOF & GUTTERS 1''5 Home Espaiiol Contact Safety & Health Claims & Insurance Washington State Department of I, Labor & Industries Search L&I Page 1 of 2 A -Z index Help My L&I Workplace Rights Trades & Licensing BLUE STAR ROOF & GUTTERS LLC Owner or tradesperson Principals JOHNSON, ROBERT NEIL, PARTNER/MEMBER Doing business as BLUE STAR ROOF & GUTTERS LLC WA UBI No. 604 079 620 12863 NORTHUP WAY BELLEVUE, WA 98005 425-455-5881 KING County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties ROOFING License no. BLUESSR837CH Effective — expiration 02/08/2017— 02/08/2019 Bond Wesco Insurance Co Bond account no. 46WB083258 $6,000.00 Received by L&I Effective date 02/08/2017 02/06/2017 Expiration date Until Canceled Insurance ................._...__. Rockingham Casualty Company $1,000,000.00 Policy no. RWAG20177600 Received by L&I Effective date 02/02/2018 02/03/2017 Expiration date 02/03/2019 Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts ......... No L&I tax debts are recorded for this contractor license during the previous 6 year period, u some debts may be recorded by other agencies. License Violations .......... _........................................ No license violations during the previous 6 year period. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=604079620&LIC=BLUESSR837CH&SAW= 8/24/2018 BLUE STAR ROOF & GUTTERS IdLC Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 488,436-02 .............................. Doing business as BLUE STAR ROOF & GUTTERS Estimated workers reported N/A L&I account contact T5 / MELISSA VEST (360)902-5613 - Email: VESM235@Ini.wa.gov Account is closed. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes .................................................... No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=604079620&LIC=BLUESSR837CH&SAW= 8/24/2018