Loading...
HomeMy WebLinkAboutPermit D18-0253 - 4018 SOUTH 148TH STREET - HOUSE DEMOLITION4018 DEMOLITION 4018 S 148T" ST D18-0253 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 0040000971 Permit Number: 4018 5 148TH ST Project Name: 4018 DEMOLITION Issue Date: Permit Expires On: D18-0253 11/27/2018 5/26/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: SOHAL MOHINDER SINGH 10650 SE 213TH ST, KENT, WA, 98031 MOHINDER S SOHAL 4018 S 148TH ST, TUKWILA, WA, 98168 OWNER AFFIDAVIT - MOHINDER SINGH N/A - UNDER $5000 Phone: (206) 841-1431 Phone: Expiration Date: DESCRIPTION OF WORK: DEMOLITION OF HOUSE PUBLIC WORKS ACTIVITIES INCLUDE TEMPORARY AND PERMANENT EROSION CONTROL. REFER TO L16-0057 FOR TREE REPLACEMENT- CODE ENF. ce16-0286. Project Valuation: $4,000.00 Type of Fire Protection: Sprinklers: NO Fire Alarm: NO Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $577.77 Occupancy per IBC: R-3 Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 Permit Center Authorized Signature: 0 Date: tr 1 hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: i i M!N,P2,1„ - cry 11,4 - Date: i / — t (I' This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 4: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 5200 EROSION MEASURES 5210 EROSION MEASURES FNL 0101 PRE -CONSTRUCTION 1600 PUBLIC WORKS FINAL CITY OF TUK 44 Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No.1 0"1,q1 Project No. Date Application Accepted: (6 0 Date Application Expires: /1jlO\ I I (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: S -f Tenant Name: v PROPERTY OWNER Name: M.O kI oD . So'14L— Address: 4,0 1pb-g' '/,n �T ' City: r71.1k W? l—fA'`-�State: 1i...A Zip: 1 102 CONTACT PERSON - person receiving all project communication Name: /� 1� �► Pi i IJP �._Cts- --S • 4--- Y' Address:' ^` b .5-0 & c0-13 S 1 -- —_City:_ City: -te..... State: kiZip: Q n 3' 4 -.11 - Phone: C1'q / 0 14I ( 4 l) Fax: c:9_,c,_ 8st ,_ S Email: M O hA'I-- 0__.---041/ } en . C -e... GENERAL CONTRACTOR INFORMATION Company Name: Address: Architect Name: Address: City: State: State: Zip: Zip: Phone: Fax: State: Zip: Contr Reg No.: f Fax: Exp Date: Email: Tukwila Business License No.: • H:\Applications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: ❑ Yes ❑..No ARCHITECT OF RECORD Company Name: INCJ N S2_.__— Architect Name: Address: V r4 City: State: Zip: Phone: Fax: Email: State: ENGINEER OF RECORD Name: Company Name: t� `f; Engineer Name: V r4 Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATION.,,,,,06-431-3670 Valuation of Project (contractor's bid price): $ 461S1) tp Existing Building Valuation: $ Describe the scope of work (please provide detailed information): p L1 coA 2t-r4V�-176 c Will there be new rack storage? ❑ ....Yes ..No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft):r Floor area of principal dwelling: % h 3 D Floor area of accessory dwelling: /4119,r►�% *Provide docume i n that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm 15r None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If 'yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2012 ApplicationsU'ermit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC ls` Floor 10 3 v t�,./ "1 .5___ 2nd Floor 4---10 t-0 S.- 3"' Floor ND(4L Floors thru Basement h101%) Accessory Structure* NV NI 5_ Attached Garage Nl,n1L. Detached Garage 'kJ D..35_, Attached Carport P.-19 �� Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft):r Floor area of principal dwelling: % h 3 D Floor area of accessory dwelling: /4119,r►�% *Provide docume i n that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm 15r None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If 'yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2012 ApplicationsU'ermit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 2 of 4 PUBLIC WORKS PERMIT INFOIATION — 206-433-0179 Scope of Work (please provide detailed information): 1CAD S AP L.1 ATt R. ( S4 iJ .-. — 6LPT L4Tk 4 Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District Et.. Tukwila ...Water District #125 0 .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ .. Sewer Use Certificate Valley View 0 ...Sewer Availability Provided ❑...Highline 0... Renton ❑ ... Renton 0... Seattle Septic System: 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): g.. Civil Plans (Maximum Paper Size — 22" x 34") .. Technical Information Report (Storm Drainage) 0 .. Bond ❑...Insurance 0... Easement(s) Proposed Activities (mark boxes that apply): ❑ .. Right-of-way Use - Nonprofit for less than 72 hours ❑ .. Right-of-way Use - No Disturbance ❑ .. Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way ❑ ❑ .. Total Cut ❑ .. Total Fill cubic yards cubic yards 0... Geotechnical Report 0...Maintenance Agreement(s) ❑ .. Traffic Impact Analysis ❑ .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) D... Right-of-way Use - Profit for less than 72 hours O ...Right-of-way Use — Potential Disturbance O ...Work in Flood Zone 0... Storm Drainage ❑ .. Sanitary Side Sewer 0...Abandon Septic Tank 0...Grease Interceptor ❑ .. Cap or Remove Utilities 0...Curb Cut ❑... Channelization ❑ .. Frontage Improvements 0...Pavement Cut 0...Trench Excavation ❑ .. Traffic Control 0...Looped Fire Line 0...Utility Undergrounding ❑ .. Backflow Prevention - Fire Protection Irrigation Domestic Water O .. Permanent Water Meter Size (1) " WO # (2) " WO # (3) " WO # ❑ .. Temporary Water Meter Size (1) " WO # (2) " WO # (3) " WO # ❑ .. Water Only Meter Size WO # ❑ .. Deduct Water Meter Size " ❑ .. Sewer Main Extension Public ❑ Private ❑ ❑ .. Water Main Extension Public 0 Private 0 FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) 0 .. Water 1=1.. Sewer 0 .. Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H: \ApplicationsWorms-Applications On Line\2012 ApplicationsTermit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 3 of 4 PERMIT APPLICATION NOTES —' tr Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: LAI 0' tr g Print Name: im. - Day Telephone: c o 6 S 41 JLI'j Mailing Address: to C.SV S E 4:x13 -*N ST H:\Applications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh 1<r L4A- g°1 City State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT I QUANTITY PAID $260.25 PermitTRAK D18-0253 Address: 4018 S 148TH ST Apn: 0040000971 $260.25 DEVELOPMENT $10.00 PW CONSTRUCTION PLAN REVIEW R000.345.830.00.00 0.00 $5.00 PW PERMIT ISSUANCE/INSPECTION FEE R000.342.400.00.00 0.00 $5.00 PUBLIC WORKS $250.00 BASE APPLICATION FEE R000.322.100.00.00 0.00 $250.00 TECHNOLOGY FEE $0.25 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R15906 R000.322.900.04.00 0.00 $0.25 $260.25 Date Paid: Tuesday, November 27, 2018 Paid By: MOHINDER S SOHAL Pay Method: CASH Printed: Tuesday, November 27, 2018 12:22 PM 1 of 1 SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $317.52 D18-0253 Address: 4018 S 148TH ST Apn: 0040000971 $317.52 DEVELOPMENT $308.92 PERMIT FEE R000.322.100.00.00 0.00 $172.07 PLAN CHECK FEE R000.345.830.00.00 0.00 $111.85 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $25.00 TECHNOLOGY FEE $8.60 TECHNOLOGY FEE R000.322.900.04.00 0.00 TOTAL FEES PAID BY RECEIPT: R15131 $8.60 $317.52 Date Paid: Thursday, August 09, 2018 Paid By: SOHAL MOHINDER SINGH Pay Method: CHECK 1731 Printed: Thursday, August 09, 2018 3:34 PM 1 of 1 CRWSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 4/Ng D/,,L,04 T of Insp coon: OKI Idol tiAlin- 1/01 Address: Date Called: Special Instructions: R, J �� _ �" r 0/Z017 Date Wanted:: ! 2,' id -0 a.m. p.m. Requester: Phone No: 171 Approved per applicable codes. Corrections required prior to approval. COMMENTS: �31•ti;1 d 1 1 ''-L Inspector: 30 Cly REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit it6 X53 CITY OF TUKWILA BUILDI DIVISIO 6300 Southcenter Blvd., #100, Tukwila. WA 98 88 (206) 431- Permit Inspection Request Line (206) 438-9355 Prr — Project: i itot� D IooLIT Type of In ction: _ .� Address: Apt?? 146r4 kr. Date Called: Special Instructions: op. kJ, ihl.4 ? L ' Date Wanted: t, t9-19 p.m. Requester: iV� ifYit l e Phone�p " �' 3i ❑ Approved per applicable codes. ['Corrections required prior to approval. COMMENTS: — s eet`N {-t it7A4,46. Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. (3 f Itsi c; c _l_, Pit ;•/ EXPIRES: 4/24// 9 1 /7 ✓vI '/ 7 REVIEWED FOR CODE COMPLIANC APPROVED NOV 21 2018 City of Tukwila BUILDING DIVISION] Mx) : o. /4I /NDz viii P-Y7NS/a,1, lip NN7HDOT. � 4) 40 AlfA r' 110 /o 1 r YP �� \4 , I /o'TY!?` el cisme • Sof* 64,,.11. 71411h St 7)1P-oat� PARCEL I 004000971 ADDRESS: 40111S JAM ST TUKWIL*, WA SUN TOTAL AREA ■ 20111 SQ.FT NORTH DRAWN S.0 CHECKED SS ISSUE DATE OS -15.201e TREE • STUMP CONSULTANTS: ARCHITECTURAL a ENGINEERING, SOLUTIONS 3/4'� Nd 9f� IN 71'S xhibit /ii 01 171 4' /co\' Nod 7 replaceme rees ar require . ' lantg more tha 7 trees is at ' . roperty owner's escretion. -NEV 49.6.72-1-m-- VA BI"'-- VA c', N PAAKt E s `l VII T,e �7P 7 APPROVED DE 40 9E-DsfoN NOV 2018 City of Tukwila PUBLIC Works CORRECTION LTR# 1 /'Pie/ T ,V •T 1° . I N7, 4A7Hli RECEIVF") / CITY OF TLS+. tr LA NUV 1 4 'aid /1111X47''" �GOIV /Z 7-414°1). /1 -yo' �/- PERMIT CENTER NOTICE TO CONTRACTOR CONSTRUCTION CONTRACTOR'S RESPONSIBILITY' Before bidding or starting any construction work, you are required to obtain a written asbestos report from the building owner or owner's agent. The report must be based on a survey by an accredited AHERA building inspector unless the building owner assumes materials in the structure are asbestos or has other convincing documents showing asbestos is not present in the work area. A building owner may know asbestos has been removed during prior work or that a new building has been constructed using materials certified to be asbestos free. If you discover suspect asbestos materials, you must report them to the building owner within 24 hours. Asbestos materials may be found in enclosed structures or between other materials, where they are not accessible before. work. State law specifies a minimum $250 per day fine for failure to obtain the asbestos report. This fine can be applied to both the contractor and building owner. Additional fines may be applied if workers are exposed to airborne asbestos. Washington State Department of Labor & Industries regulations & policy with regards to asbestos removal. A Copy of the asbestos report must be made available to the building inspector prior to the first inspection. In addition, if asbestos has been found, confirmation of the completed abatement work must be provided to the building inspector. Inspection scheduling will not be accepted until this documentation is received by the building inspector. Environmental Specialties 4227 S Meridian, STE C, #625 • Puyallup, WA 98373 • (253) 683-1144 ES Reviewed by JLS Asbestos Inspection House 4018 S 148th St Tukwilla, WA 98168 Performed For Mohinder Sohal 24915 104th Ave SE Kent, WA 98030 Consultant Environmental Specialties 4227 S Meridian, Ste C, #625 Puyallup, WA 98373 tLSo2s 3 RECEIVED CITY OF TUKWILA MAY 17 2019 PERMIT CENTER . S Introduction On April 26, 2019 Environmental Specialties inspected this house for asbestos materials. Demolition is planned for this structure. This inspection report includes data that describes the type of materials found, their quantities, where appropriate, and their asbestos content. The report can also be used as a planning aid for all construction, maintenance, abatement and demolition work associated with the structure. Facilities Description This structure is a wood framed 1100 square foot residential home built in the 1940's. The house had a major addition and cosmetic remodels with several types of floor materials. Wood strip flooring, linoleum, sheet vinyl and carpet cover the floors. Two layers cover the dining, kitchen, and utility areas. The floor in the utility is partially collapsed. Shiplap is the base sheeting on the floors and walls. The building has a concrete block foundation and a short two foot crawlspace. Exterior siding is composition shingle material bonded to a wood fiber board (fir-tex). Vertical cedar board siding covers the sides and back of the house. Interior walls and ceilings are gypsum wallboard with no texture. Some fiberglass batts are in the attic. No wall or underfloor insulation is present. Heat is a forced air gas furnace with metal ducts. Hot water is provided by an electric hot water tank. Plumbing is steel and electrical is an old fuse panel with some old and new wiring. Roofing is composition shingles. Inspection & Sampling Procedures Puget Sound Clean Air Agency (PSCAA) and Labor & Industries regulations require an inspection of all buildings for the presence of asbestos containing materials prior to renovation and/or demolition. Asbestos containing materials are defined as those building materials containing one percent or more of asbestos as verified by laboratory analysis. Asbestos containing materials are sub -divided into three types: surfacing materials, thermal system insulation, and miscellaneous materials. Surfacing materials are defined as those materials that are sprayed -on, troweled -on or otherwise applied to surfaces including, but not limited to, acoustical plaster on ceilings, paints, fireproofing materials on structural members, or other materials on surfaces for decorative purposes. Thermal system insulation indicates material applied to pipes, fittings, boilers, tanks, ducts, or other structural components to prevent heat loss or gain. All other materials are considered to be miscellaneous materials. All surfacing materials, thermal system insulation and flooring installed in structures prior to ES. Reviewed by JLS S 1980 are presumed to contain asbestos unless proven otherwise by a licensed building inspector. The number of samples collected depends on the type of material and its quantity. In order to prove that suspect or presumed surfacing materials do not contain asbestos at least three samples of each homogeneous area are required. Five samples are required for areas greater than 1,000 square feet and seven are required for areas greater than 5,000 square feet. Thermal system insulation requires at least three samples be collected. One sample of each suspect miscellaneous material must also be collected. Each sample was collected and placed into a separate, sealed, plastic bag. They were then individually numbered. When possible, samples were collected from areas or materials that were previously damaged. Sampling equipment was decontaminated after each sample was collected. Once collected, the samples were delivered to an accredited laboratory, accompanied by a chain of custody describing each sample. The samples were then analyzed using Polarized Light Microscopy (PLM) Stain Dispersion technique in accordance with EPA Method 600/R- 93/116. Additional treatment and tests may have been used as required to define a sample's composition. Non -Asbestos Containing Suspect Materials Following is a list of suspect materials that were identified, tested and determined not to contain asbestos or have less than 1% percent asbestos by weight: Material Type Location Quantity Description Gypsum Wallboard Walls & Ceilings 1800 sq/ft Wallboard mud positive in two of three samples, non -asbestos as composite. 9x9 Floor Tiles Kitchen 200 sq/ft Gray plus black asphalt backing 9x9 Floor Tiles Kitchen/dining 200 sq/ft Red plus black asphalt backing 12x12 floor Tiles Entry 12 sq/ft Tank floor tiles by front door Sheet Vinyl Kitchen/dining 300 sq/ft Brown patterned top layer Sheet Vinyl Kitchen/dining 300 sq/ft Red/cream plus black asphalt backing Sheet Vinyl Bath 40 sq/ft Addition, White ES Reviewed by JLS Building Paper Floors & Roof sq/ft 15 lb asphalt building paper Siding Comp & Fiber Board 10000 sq/ft Comp & fiber board siding Wire Jackets Panel 5001n/ft Knob & Tube plus silver/black outer jackets Buss Bar Panel 1 sq/ft Plastic buss fuse holder Asbestos Containing Materials Material Type Location Quantity Description Sheet Vinyl Furnace/utility 8sq/ft Tan patterned top layer of sheet vinyl, remnants and pieces 9x9 inch Floor Tiles Halls 7 Main Bath 100 sq/ft Cream floor tiles Black Mastic Main Bath 40 sq/ft Main Bath black mastic only Fixture Wire 4 light fixtures 8 ln/ft Waxed black and white fixture connection wiring Window putty Window glass 10 units Putty stopped glass in wood frames, covered with plywood ES Reviewed by JLS Conclusion Five asbestos materials were found. The sheet vinyl on top in the utility furnace room contains asbestos. This material only partially covers the floor that is in poor condition. 9x9 inch vinyl asbestos tiles cover the floors in the addition hall, main bathroom hall and the main bathroom. The black mastic in the main bathroom on the bottom of the tiles also contains asbestos. Fixture wire connection wiring in four light fixtures contains asbestos. This material is waxed. Window putty on the 10 wood frame windows contains asbestos. Wallboard mud was found to contain asbestos in two of three samples tested. This material can be considered as a composite and non -asbestos as a unit. Consult Washington WRD 23.30 for further information and required contractor responses. Should any additional suspect materials be found it is recommended that a certified inspector determine whether the materials contain asbestos. Puget Sound Clean Air Agency and Washington DOSH regulations require that all asbestos containing materials be properly handled during demolition and renovation and that a survey of the asbestos containing materials be provided to all contractors and posted at the site to prevent potential accidental asbestos exposure. Inspector Endorsement Rix F. 54 Inspector: Certified AHERA Building Inspector, Inspector # 172402 Attachments: Sketch, EMC Laboratory Analysis ES Reviewed by JLS Asbestos Sampling Location EHouse,40i X S 148th St, Tukwilla, Page , o COMPANY NAME: Address: CONTACT: Phone/Fax: Email: Now Accepting: CHAIN OF CUSTODY EMC Labs, Inc. 9830 S. 5150 St., Ste B-109 Phoenix, AZ 85044 (480) 940-5294 Fax (480) 893-1726 Environmental Specialties 4227 S Meridian, Ste C, #625 Puyallup, WA 98373 Robert Simons 253-683-1144 rscrosi@hotmail.com VISA — MASTERCARD COMPLETE ITEMS 1-4: (Failure to complete any items ma BILL TO: TAT: Rec' d: MAY 01 P.M' EMC USE ONLY (If Different Location) Environmental Specialties 4227 S Meridian, Ste C, #625 Puyallup, WA 98373 Price Quoted: $ / Sample $ / Layers e a delay in processing or analyzing your samples) 1. TURNAROUND TIME: [Same Day Rush] 1'-2 D. s] [3-4-5 Days] [6-10 Days] ****Prior confirmation of turnaround time is required **""Additional charges for rush analysis (please call marketing department for pricing details) ****Laboratory analysis may be subject t . ff credit terms are not met 2. TYPE OF ANALYSIS: [Bu it -PCM] [Lead] [Point Count] [Fungi.. AOC, W -C, Bulk, Swab, Tape] DISPOSAL INSTRUCTIONS: sllt,f samples at EMC] / [Return samples to me at my expense] at preference, EMC Ivf// dfsoose ofsamp/es D days from ana/ysis.l 4. Project P.O. Number: Name: ProjectNumber: I( ca /'/V7141 EMC SAMPLE # CLIENT AMPLE it DATE & TIME SAMPLED %1 LOCATION/MATERIAL TYPE Co6 — 4,ttki4,44, my Ss:mples Accepted Yes-/ No N AIR SAMPLE ON INFO / COMMENTS OFF FLOW RATE i G� (/O� J[ A. — s/c, cd -d ge..- - N a� 3 / 1.(i //U !1 — tJ tC 1I4r N �J/ 1 �l ` .�r 1ot��'p-%1 1-Ztt /!/o N /5(,f�-, /(�� -/ Y . - (9 Ptill f S -_/ea I1 N �j e7X G- /2,ed t 6 find e Y N �'--'T-'-- "' Lam►) .— !/1 Y N 8 q °1 ,6'1/-- gim - 691.46.114 �Sir q IvQ, My &/A 9X4 Ci'"eot•-rrp/A,.k. .77/ "' Cvea.._ /i(rS/ /VCl h eafti dxeQ e.. kiwee ,f JZX .l a-0ce Fr _ tT:.�.-/V y Y N Y N Y N Y N Y N �j --- [ 0 /0 14. D 1 I 12— 13 met $� 447 "i, �"LXl Y N 19 /J ' rafeheLkir, (,9 SPECIAL INSTRUCTIONS: Sample Collector: (Print) «/ p Relinquished by: Relinquished by: Relinquished by: 14.4... iF;J v b (Signature].1Ls�u� Date/Tim Received by: Iwru...re a Date/Time: / Date/Time:9f 1 ( °Iteceived by. --Date/Tim Date/Time Received by: Date/Time:__ •"* In the event of any dispute between the above parties for these services or otherwise, parties agree that jurisdiction and venue will be in Phoenix, Arizona and prevailing party will be entitled to attorney's fees and court costs. Page CHAIN OF CUSTODY EMC Labs, Inc. 9830 S. 51° St., Ste B-109 Phoenix, AZ 85044 (480) 940-5294 Fax (480) 893-1726 COMPANY NAME: Environmental Specialties Address: CONTACT: Phone/Fax: Email: 4227 S Meridian, Ste C, #625 Puyallup, WA 98373 Robert Simons 253-683-1144 rscrosihotmail.com Now Accepting: VISA — MASTERCARD BILL TO: LAB#: TAT: Rec'd: EMC USE ONLY (tf Different Location) Environmental Specialties 4227 S Meridian, Ste C, #625 Puyallup, WA 98373 Price Quoted: $ / Sample $ / Layers COMPLETE ITEMS 1-4: (Failure to complete any items maycaus a delay in processing or analyzing your samples) 1. TURNAROUND TIME: [Same Day Rush] ****Prior confirmation of turnaround time is required ****Additional charges for rush analysis (please call marketing department for pricing details) ****Laboratory analysis may be subject t4elayrffesredit terms are not met [3-4-5 Days]. [6-10 Days] 2. TYPE OF ANALYSIS: 3. DISPOSAL INSTRUCTIO Bulk -PL -[,4'r-PCM] [Lead] [Point Count] [Fungi: AOC, W -C, Bulk, Swab, Tape] iso of samples at EMC] / [Return samples to me at my expense] dt indica a preference, EMC will dispose of samples 30 dans from analysis.) 4. Project P.O. Number: Name: r.. .� ProjectNumber: 149 / !f . / f%� EMC SAMPLE # CLIENT SAMPLE # DATE & TIME SAMPLED LOCATION/MATERIAL TYPE Samples Accepted Yes / No AIR SAMPLE INFO / COMMENTS ON OFF FLOW RATE 1 (/' Jt' . 4Ir` �f 4( IX'i.e t e / Ne_ ink -1f I N N /I(7 /'7 25 `( O we (CI ! q to0"4-0(04)1"C - Ve.A:klifs0_ N Y N Y N Y N Y N Y N Y N Y N -- Y N Y N Y N Y N SPECIAL INSTRUCTIONS: Sample Collector: (Prin,) % /G��J1vt*6z-s-ra (Signature) Relinquished by: i/Y. (1' re, c4,0 Date/Time:/ 7r Received by71)461'-•C """ Date/Time:F/ ti Relinquished by: 7'Ctr,w,.rub Date/Time:5 cy)►� eceived by;,_ )/ Date/Tim `.. Relinquished by: Date/Time Received by: Date/Time:_ ^* In the event of any dispute between the above parties for these services or otherwise, parties agree that jurisdiction and venue will be in Phoenix, Arizona and prevailing party will be entitled to attorney's fees and court costs. EMC LABS, INC. Laboratory Report 9830 S. 51st Street, Suite B109, Phoenix, AZ 85044 0219419 Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726 Bulk Asbestos Analysis by Polarized Light Microscopy NVLAP#101926-0 Client: ENVIRONMENTAL SPECIALTIES Job# / P.O. #: Address: 4227 MERIDIAN S. STE C #625 Date Received: 05/01/2019 PUYALLUP, WA 98373 Date Analyzed: 05/03/2019 Collected: 04/26/2019 Date Reported: 05/03/2019 Project Name: SOHAL - 4018 S. 148TH EPA Method: EPA 600/R-93/116 Address: Submitted By: ROBERT SIMONS Collected By: Lab ID Sample Layer Name / Asbestos Asbestos Type Non -Asbestos Client ID Location Sample Description Detected (%) Constituents 0219419-001 BACK BEDRM ADD LAYER 1 1 Gypsum Wallboard, White/ Brown/ Off White No None Detected Cellulose Fiber Gypsum Mica Quartz Carbonates LAYER 2 Yes Chrysotile 2% Cellulose Fiber Texture/ Paint, White/ Off White Carbonates Mica Quartz Binder/Filler LAYER 3 Yes Chrysotile 2% Cellulose Fiber Texture/ Paint, Lt. Green/ Off Carbonates White Mica Quartz Perlite Binder/Filler 12% 88% 2% 96% <1% 97% 0219419-002 KITCHEN 2 LAYER 1 Gypsum Wallboard, White/ Brown/ Off White LAYER 2 Texture, White/ Off White No None Detected Cellulose Fiber Fibrous Glass Gypsum Mica Quartz Carbonates Yes Chrysotile 2% Cellulose Fiber Carbonates Mica Quartz Binder/Filler 10% 2% 88% 2% 96% Page 1 of 7 EMC LABS, INC. Laboratory Report 9830 S. 51st Street, Suite B109, Phoenix, AZ 85044 0219419 Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726 Bulk Asbestos Analysis by Polarized Light Microscopy NVLAP#101926-0 Client: ENVIRONMENTAL SPECIALTIES Job# / P.O. #: Address: 4227 MERIDIAN S. STE C #625 Date Received: 05/01/2019 PUYALLUP, WA 98373 Date Analyzed: 05/03/2019 Collected: 04/26/2019 Date Reported: 05/03/2019 Project Name: SOHAL - 4018 S. 148TH EPA Method: EPA 600/R-93/116 Address: Submitted By: ROBERT SIMONS Collected By: Lab ID Sample Layer Name / Asbestos Asbestos Type Non -Asbestos Client ID Location Sample Description Detected (%) Constituents 0219419-003 BACK UTILITY ADD LAYER 1 3 Gypsum Wallboard, White/ Brown/ Off White LAYER 2 Textured Paint, White/ Off White/ Blue Note: Layer is mainly Paint - little Texture present No None Detected No None Detected Cellulose Fiber 12% Gypsum Mica Quartz Carbonates 88% Carbonates Quartz Perlite Binder/Filler 100% 0219419-004 KIT DINING LAYER 1 4 Sheet Vinyl, Tan/ Red LAYER 2 Mastic, Brown Note: Very small amount of mastic No None Detected No None Detected Cellulose Fiber 15% Fibrous Glass 5% Carbonates Quartz Binder/Filler 80% Cellulose Fiber 5% Fibrous Glass <1% Carbonates Quartz Gypsum Binder/Filler 94% Page 2 of 7 EMC LABS, INC. Laboratory Report 9830 S. 51st Street, Suite B109, Phoenix, AZ 85044 0219419 Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726 Bulk Asbestos Analysis by Polarized Light Microscopy NVLAP#101926-0 Client: ENVIRONMENTAL SPECIALTIES Job# / P.O. #: Address: 4227 MERIDIAN S. STE C #625 Date Received: 05/01/2019 PUYALLUP, WA 98373 Date Analyzed: 05/03/2019 Collected: 04/26/2019 Date Reported: 05/03/2019 Project Name: SOHAL - 4018 S. 148TH EPA Method: EPA 600/R-93/116 Address: Submitted By: ROBERT SIMONS Collected By: Lab ID Sample Layer Name / Asbestos Asbestos Type Non -Asbestos Client ID Location Sample Description Detected (%) Constituents 0219419-005 5 LAYER 1 9"x9" Floor Tile, Gray/ Black LAYER 2 Mastic, Black LAYER 3 Mastic, Yellow No None Detected No None Detected No None Detected Cellulose Fiber 15% Synthetic Fiber 5% Carbonates Gypsum Quartz Binder/Filler 80% Cellulose Fiber 4% Synthetic Fiber <1% Carbonates Gypsum Quartz Binder/Filler 95% Cellulose Fiber 3% Synthetic Fiber <1% Carbonates Gypsum Quartz Binder/Filler 96% 0219419-006 6 LAYER 1 No None Detected 9"x9" Floor Tile, Red/ Black LAYER 2 Mastic, Black No None Detected Cellulose Fiber 15% Synthetic Fiber 5% Carbonates Gypsum Quartz Binder/Filler 80% Cellulose Fiber 4% Synthetic Fiber <1% Carbonates Gypsum Quartz Binder/Filler 95% Page 3 of 7 EMC LABS, INC. Laboratory Report 9830 S. 51st Street, Suite B109, Phoenix, AZ 85044 0219419 Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726 Bulk Asbestos Analysis by Polarized Light Microscopy NVLAP#101926-0 Client: ENVIRONMENTAL SPECIALTIES Job# / P.O. #: Address: 4227 MERIDIAN S. STE C #625 Date Received: 05/01/2019 PUYALLUP, WA 98373 Date Analyzed: 05/03/2019 Collected: 04/26/2019 Date Reported: 05/03/2019 Project Name: SOHAL - 4018 S. 148TH EPA Method: EPA 600/R-93/116 Address: Submitted By: ROBERT SIMONS Collected By: Lab ID Sample Layer Name / Asbestos Asbestos Type Non -Asbestos Client ID Location Sample Description Detected (%) Constituents 0219419-007 UTILITY FURNACE LAYER 1 7 Sheet Vinyl, Tan LAYER 2 Residual Floor Mastic, Black Yes Chrysotile 20% Yes Chrysotile 5% Gypsum Quartz Binder/Filler Carbonates Quartz Binder/Filler 80% 95% 0219419-008 BOTH BATH HALLS LAYER 1 Yes Chrysotile 8 9"x9" Tile, Black LAYER 2 Mastic, Gray No None Detected 3% Carbonates Quartz Binder/Filler Cellulose Fiber Synthetic Fiber Carbonates Quartz Gypsum Binder/Filler 97% 1% <1% 98% 0219419-009 MA BATH 9 LAYER 1 9"x9" Tile, Off White LAYER 2 Mastic, Black Note: Difficult to separate adjacent layer Yes Chrysotile 8% Carbonates Gypsum Quartz Binder/Filler 92% Yes Chrysotile <1% Cellulose Fiber 2% Carbonates Gypsum Quartz Binder/Filler 97% Page 4 of 7 EMC LABS, INC. Laboratory Report 9830 S. 51st Street, Suite B109, Phoenix, AZ 85044 0219419 Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726 Bulk Asbestos Analysis by Polarized Light Microscopy NVLAP#101926-0 Client: ENVIRONMENTAL SPECIALTIES Job# / P.O. #: Address: 4227 MERIDIAN S. STE C #625 Date Received: 05/01/2019 PUYALLUP, WA 98373 Date Analyzed: 05/03/2019 Collected: 04/26/2019 Date Reported: 05/03/2019 Project Name: SOHAL - 4018 S. 148TH EPA Method: EPA 600/R-93/116 Address: Submitted By: ROBERT SIMONS Collected By: Lab ID Sample Layer Name / Asbestos Asbestos Type Non -Asbestos Client ID Location Sample Description Detected (%) Constituents 0219419-010 LAYER 1 No None Detected 10 Sheet Vinyl, Red/ Black/ Gray LAYER 2 Mastic, Brown No None Detected Cellulose Fiber Synthetic Fiber Carbonates Quartz Binder/Filler Cellulose Fiber Synthetic Fiber Gypsum Quartz Carbonates Binder/Filler 15% 5% 80% 3% <1% 96% 0219419-011 BATH ADD LAYER 1 11 Sheet Vinyl, Beige/ Gray LAYER 2 Mastic, Brown/ Black Note: Unable to separate adjacent layers No None Detected No None Detected Cellulose Fiber Fibrous Glass Carbonates Gypsum Quartz Binder/Filler Cellulose Fiber Synthetic Fiber Carbonates Gypsum Quartz Binder/Filler 17% 3% 80% 5% 2% 93% 0219419-012 ENTRY 12 LAYER 1 No None Detected 12"x12" VFT, Gray LAYER 2 Mastic, Clear No None Detected Carbonates Quartz Binder/Filler 100% Cellulose Fiber 3% Synthetic Fiber 1% Carbonates Quartz Gypsum Binder/Filler 96% Page 5 of 7 EMC LABS, INC. Laboratory Report 9830 S. 51st Street, Suite B109, Phoenix, AZ 85044 0219419 Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726 Bulk Asbestos Analysis by Polarized Light Microscopy NVLAP#101926-0 Client: ENVIRONMENTAL SPECIALTIES Job# / P.O. #: Address: 4227 MERIDIAN S. STE C #625 Date Received: 05/01/2019 PUYALLUP, WA 98373 Date Analyzed: 05/03/2019 Collected: 04/26/2019 Date Reported: 05/03/2019 Project Name: SOHAL - 4018 S. 148TH EPA Method: EPA 600/R-93/116 Address: Submitted By: ROBERT SIMONS Collected By: Lab ID Sample Layer Name / Asbestos Asbestos Type Non -Asbestos Client ID Location Sample Description Detected (%) Constituents 0219419-013 Asphalt Paper, Black No None Detected Cellulose Fiber 13 Carbonates Gypsum Binder/Filler 65% 35% 0219419-014 14 LAYER 1 No None Detected Siding, Black/ Gray LAYER 2 No None Detected Fiber Board, Brown Cellulose Fiber Carbonates Quartz Binder/Filler Cellulose Fiber Carbonates Gypsum Binder/Filler <1% 99% 98% 2% 0219419-015 Wire Jacket, Black/ Gray No None Detected Cellulose Fiber 15 Carbonates Quartz Binder/Filler 40% 60% 0219419-016 16 Wire Insulation, Gray Yes Chrysotile 85% Amosite 5% Carbonates Gypsum Binder/Filler 10% 0219419-017 Wire Insulation, Black No None Detected Cellulose Fiber 17 Carbonates Gypsum Binder/Filler 85% 15% 0219419-018 Wire Buss, Black No None Detected Cellulose Fiber 18 Carbonates Quartz Binder/Filler 3% 97% Page 6 of 7 EMC LABS, INC. Laboratory Report .9830 S. 51st Street, Suite B109, Phoenix, AZ 85044 0219419 Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726 Bulk Asbestos Analysis by Polarized Light Microscopy NVLAP#101926-0 Client: ENVIRONMENTAL SPECIALTIES Job# / P.O. #: Address: 4227 MERIDIAN S. STE C #625 Date Received: 05/01/2019 PUYALLUP, WA 98373 Date Analyzed: 05/03/2019 Collected: 04/26/2019 Date Reported: 05/03/2019 Project Name: SOHAL - 4018 S. 148TH EPA Method: EPA 600/R-93/116 Address: Submitted By: ROBERT SIMONS Collected By: Lab ID Sample Layer Name / Asbestos Asbestos Type Non -Asbestos Client ID Location Sample Description Detected (%) Constituents 0219419-019 19 Window Putty, Gray/ White/ Turquoise Yes Chrysotile 2% Carbonates Quartz Binder/Filler 98% Analyst - Dustin White Signatory - Lab Director - Kurt Kettler Distinctly stratified, easily separable layers of samples are analyzed as subsamples of the whole and are reported separately for each discernible layer. All analyses are derived from calibrated visual estimate and measured in area percent unless otherwise noted. The report applies to the standards or procedures identified and to the sample(s) tested. The test results are not necessarily indicated or representative of the qualities of the lot from which the sample was taken or of apparently identical or similar products, nor do they represent an ongoing quality assurance program unless so noted. These reports are for the exclusive use of the addressed client and that they will not be reproduced wholly or in part for advertising or other purposes over our signature or in connection with our name without special written permission. The report shall not be reproduced except in full, without written approval by our laboratory. The samples not destroyed in testing are retained a maximum of thirty days. The laboratory measurement of uncertainty for the test method is approximately less than 1 by area percent. Accredited by the National Institute of Standards and Technology, Voluntary Laboratory Accreditation Program for selected test method for asbestos. The accreditation or any reports generated by this laboratory in no way constitutes or implies product certification, approval, or endorsement by the National Institute of Standards and Technology. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Polarized Light Microscopy may not be consistently reliable in detecting asbestos in floor coverings and similar non -friable organically bound materials. Page 7 of 7 • rw • •' •�- '.I_.#. .1 ,CA 12/3/2019 0 C y� City of Tukwila p r a° Department of CommunityDevelopment 3 MOHINDER S SOHAL 10650 SE 213TH ST KENT, WA 98031 RE: Permit No. D18-0253 4018 DEMOLITION 4018 S 148TH ST Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 1/26/2020. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 1/26/2020, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: D18-0253 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 �vJILAh, gsyZ City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director May 23, 2019 Mohinder Singh Sohal 24915 104th Ave SE Kent, WA 98030 RE: Request for Extension #1 Permit Number D18-0253 Dear Mr. Sohal, This letter is in response to your written request for an extension to Permit D 18-0253. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit through November 26, 2019. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, R-oa Bill Rambo Permit Technician File: Permit No. D18-0253 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov DATED: May 15th , 2019 Mohinder Singh Sohal 24915 104th Ave SE, Kent WA -98030 Kind Attn : Mr. Jim Toole. City of Tukwila Department of community development 6300 Southcenter Blvd, Suite 100 Tukwila WA -98188 Sub: Extension of time for demolition permit issued on November 27th , 2018 Expiring on 05/26/2019 RE: Permit no D18-0253 property address: 4018 S 148th St , Dear Mr. Jim Toole I am in receipt of your letter dated May 9th, 2019 regarding demolition permit expiring. I with contact f environmental specialist for asbestos inspection and remedies, copy of environmental specialist attached for your references. Now a am in contact with abetment people who can clean the asbestos as early as possible. Sir, I need extension of time to complete city code formalities for final inspection to demolish this structure. I request you to please grant me a month until June 26th ,2019 to finish this job. I shall be thankful for this favor. Thanking You Mohin Request for Extensio: # 1 Current Expiration Date: 5"2-ti Iq Extension Request: yApproved for ( d days Denied (provide explanation) Signature nitials RECEIVED CITY OF TUKWILA MAY 17 2019 PERMIT CENTER 4/1/2019 C!) City of Tukwila Department of Community Development MOHINDER S SOHAL 4018 S 148TH ST TUKWILA, WA 98168 RE: Permit No. D18-0253 4018 DEMOLITION 4018 S 148TH ST Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 5/26/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 5/26/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, 4/b(Ak-i/cet ) Kandace Nichols Permit Technician File No: D18-0253 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 August 24, 2018 City of Tukwila Department of Community Development MOHINDER S SOHAL 4018 S 148TH ST TUKWILA, WA 98168 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D 18-0253 4018 DEMOLITION - 4018 S 148TH ST Dear MOHINDER S SOHAL, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: PLANNING DEPARTMENT: MAX BAKER at (206)-431-3683 if you have questions regarding these comments. • 1) Provide site plan showing location of house on property. 2) If trees are to be removed as part of demolition, indicate location(s) on property and the size of each tree to be removed. PW DEPARTMENT: Joanna Spencer at 206-431-2440 if you have questions regarding these comments. • 1) Please submit a site plan showing house location on the lot. 2) Applicant shall contact Valley View Sewer District at 206 242-3236 to obtain a Sewer Capping permit and submit copy of this permit to Public Works. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. Sincerely, Bill Rambo Permit Technician File No. D18-0253 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Joanna Spencer From: Jim Toole Sent: Wednesday, August 15, 2018 10:16 AM To: Joanna Spencer; Minnie Dhaliwal Subject: RE: SFR 4018 DEMO @ 4018 S 148th St D18-0253 Attachments: CE16-0080_NOVO_5-29-18.pdf; 7-24-18 (2).JPG; 7-24-18 (1).JPG Good Morning. Per the issued Notice of Violation and Order, the property owner has until November 5, 2018 to replant these trees. If the task is not completed by this date, he will be assessed $250 per day for this violation. We assess the property owner for thirty days. I have recently found that when the property owner is assessed, he will bring the property into compliance. I have attached two photographs of the house in question. Also, this house has become a nuisance and blight to the neighborhood. In the recent past police and fire have been called to this property. If there is anything else I can help with, please let me know. Thank you. Jim Toole Code Enforcement Officer P 206-431-3676 E-mail: jim.toole@tukwilawa.gov Department of Community Development 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 www.tukwilawa.gov The City of opportunity, the community of choice. **My incoming and outgoing email messages are subject to public disclosure requirements per RCW 42.56 * * In every walk with nature one receives far more than he seeks. John Muir From: Joanna Spencer Sent: Wednesday, August 15, 2018 10:03 AM To: Minnie Dhaliwal <Minnie.Dhaliwal@TukwilaWA.gov> Cc: Jim Toole <Jim.Toole@TukwilaWA.gov>; Joanna Spencer <Joanna.Spencer@TukwilaWA.gov> Subject: SFR 4018 DEMO @ 4018 S 148th St D18-0253 Hi Minnie, They have submitted a demo permit application D18-0253 without a site plan, they only included a floor plan. There are also two Tree Cut permits 116-0057 aeattlien58 plus code enf. CE16-0286. If we approve this Demo, what kind of assurance we have that the replacement trees will be planted. They had also a D16-0286 demo permit for the garage which has expired. 1 Dig -02-53 (gE1F:P4:,c oNL Y) 1? JOANNA SPENCER c Development Engineer Tukwila Public Works 6300 Southcenter Blvd, Suite 100, Tukwila, WA 98188-2544 Phone: 206 431-2440 Fax: 206 431-3665 2 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0253 PROJECT NAME: 4018 DEMOLITION SITE ADDRESS: 4018 S 148 ST Original Plan Submittal X Response to Correction Letter # 1 DATE: 11/14/18 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division fMl& kii\\66 Public Works Fire Prevention Structural El M' 111214 P1 nning Division nPermit Coordinator 141 PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 11/15/18 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required n Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 12/13/18 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire D Ping ❑ PW ❑ Staff Initials: 12/18/2013 YERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0253 PROJECT NAME: 4018 DEMOLITION SITE ADDRESS: 4018 S 148TH ST X Original Plan Submittal Response to Correction Letter # Revision # Revision # DATE: 08/14/18 before Permit Issued after Permit Issued DEPARTMENTS: ,1-s c 8-1\s--( Building Division �s Coves Public Works AtA 8-a0-16 we 5\0-01�� Fire Prevention Planning Division I Structural ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: 08/16/18 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 09/13/18 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: C3 --)--1-1---k Departments issued corrections: Bldg 0 Fire ❑ Ping� PW Staff Initials: Iket 12/18/2013 Date: c o City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: D18-0253 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # .�, after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: 4018 Demolition Project Address: 4018 S 148 St Contact Person: i(\e\ o k s c fntr-V2._ Summary of Revision: Phone Number: (27.Z.0 4 3111 1 L1 1) in 1L S (fi c7, SSi...i(i-AM11-1'50 A. RECEIVED CITY OF TUKWILA. Sheet Number(s): PERMIT CENTER "Cloud" or highlight'all areas of revision including date of revi 'ot.--....., c" Received at the City of Tukwila Permit Center by: c1` _- Entered in TRAKiT on l 1-1''1 C:\Users\bill-r\Desktop\Revision Submittal Form.doc Revised: August 2015 OUTSIDE INSIDE REPAIRS DEPOSIT $ ..' PHONE: 206-242-3236 SIDE SEWER PERMIT VALLEY VIEW SEWER DISTRICT 3460 South 148th Street, Suite 100 • Seattle, Washington EASEMENT No. RECEIPT No. DATE OWNER CONTRACTOR: HOUSE ADDRESS `" " t, - BASEMENT: YES NO NAME SUB -DIVISION LOT No. BLK. No. Permit has been granted �- Ic. - Approved by Permits not valid unles 7signed by district representa we. Expiration Date 8- 16 -19 Inspector's Report Test Report WATER 0 CORRECTION LTR# 1 Roof, Downspouts, Building Footing Drains, any Ground Water Drains, etc., are not allowed to be hooked into the sewer under this permit. ALL PLUMBING OUTLETS WILL BE CONNECTED TO THE SEWER. This permit is granted subject to the conditions set forth on the District's Application For Permit and is subject to all stipulations of the District's Side Sewer Resolution as amended and which are by this reference incorporated herein as though set forth in full. Inspector "CAUTION" NO BUILDING ON SEWER EASEMENTS CALL FOR INSPECTION AT 242-3236 • DEWATER DITCH BEFORE INSPECTION • DISTRICT INSPECTION BEFORE BACKFILL • TEST SIDE SEWER BEFORE AND DURING INSPECTION RECEIVED CITY OF TUKWILA NUV 14 2018 PERMIT CENTER SEPTIC TANK The King County Health Department Uniform Plumbing Code requires septic tanks to be completely pumped and filled with earth, sand, gravel, concrete or other approved material. SAFETY The Contractor shall comply with the Washington Industrial Safety and Health Act (RAW 49.17) and Safety and Health Standards such as Safety Standards for Construction Work (Chapter 296-155 WAC), General Safety and Health Standards (Chapter 296-24 WAC), General Occupational Health Standards (Chapter 296-22 WAC) am ny oder appropriate safety and health codes. OUTSIDE INSIDE REPAIRS DEPOSIT $ APPLICATION FOR SIDE SEW R PERMIT 00L/ (D0 N/ PERMIT 4024 EASEMENT No, CARD No. DATE 9- /--- `3 2 OWNER 54c'+�C�7c�, Zflct{ YO i& ADDRESS i& 6 NS �k- NAME SUB -DIVISION CONTRACTOR 6eikiP L / BASEMENT: YES NO LOT No. BLK. No, SCALE DISTRICT APPROVAL BY rid[ vsi-^ DATE 4 - / - 93 TEST RESULTS 0 - O , / / 7 I HEREBY CERTIFY THAT THE ABOVE CONNECTION HAS BEEN MADE AS SHOWN, PRIOR TO BACKFILL BY DATE 4 -/- 93 O c� CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-367o FAX (206) 431-3665 E-mail: tukplan@ ci.tukwila.wa.us Permit Center/Building Division 206 431-367o Public Works Department 206 433-0179 Planning Division 206 431-3670 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION STATE OF WASHINGTON) ) ss. COUNTY OF KING ) n1 off i fbE2 /7 /4 C. , states as follows: [please print name] PERMIT NO: 1)\ 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under numbersiirrd5 and will therefore / not be performed by a registered contractor. e; 1' '� 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. Owner Ow ' 's Agents Signed and sworn to before me this i 1 day of R\JoofOr NOTARY I1UB�.I1C in end for t F e State of Washington Residing at Name as commissioned: Coun I'6 P1CY My commission expires: \ 170?- 18.27.090 Exemptions. The(( tration provisions of this chapter do not appl\ by a registered contractor; 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile/manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW who shall warranty service and repairs under chapter 46.7o RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is Less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed 11. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile/manufactured home dealer or manufacturer who subcontracts the installation, set-up, or repair work to actively registered contractors. This exemption only applies to the installation, set-up, or repair of the mobile/manufactured homes that were manufactured or sold by the mobile/manufactured home dealer or manufacturer; 18. An entity who holds a valid electrical contractor's license under chapter 19.28 RCW that employs a certified journeyman electrician, a certified residential specialty electrician, or an electrical trainee meeting the requirements of chapter 19.28 RCW to perform plumbing work that is incidentally, directly, and immediately appropriate to the like -in-kind replacement of a household appliance or other small household utilization equipment that requires limited electric power and limited waste and/or water connections. An electrical trainee must be supervised by a certified electrician while performing plumbing work. • Per Washington State Department of Labor and Industries lessee has been interpreted to be equivalent to owner for purposes of exemptions. FILE C`' TY PV6s/ t 2 Approval Gi tho v obt: C; r of approved Edo' Ey: Date: t1 iyci BUILDING DIVISION I Pfo than:- . NOT, . f:^.... _ r.'i;l t..:.: r;' r . r (' r a:.rn•t . 1 • • ILZ 1 Yr .• i\. 1. NJ :.".:.nical r ptng • 19T 2 - O O co W m� c0 "4:r ri a- - O b ri 017 0 N 1 GROUND FLOOR PLAN 1 �RfwVIE<<'iEt, FOR CODE COMPLIANCE : APPROVED • NOV 21 2C18 r% L�tti City of Tukwila BUILDING DIVISION C:' • A't�: (7 �tt�a�. l',�.if �d GJi:t PERMIT CENTER SHEET NO. 1- 0 w 0 ct d FILE NAME J w t7 Z O w N M N r•- 004000971 P $5 - Digo