Loading...
HomeMy WebLinkAboutPermit D18-0277 - KING COUNTY HOUSING AUTHORITY - ELEVATOR CODE COMPLIANCEKING COUNTY HOUSING AUTHORITY 14410 4ISTAVE S BLDG 1 EXPIRED 04/23/2019 D18-0277 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 0040000205 14410 41ST AVE S BLDG 1 KING COUNTY HOUSING AUTHORITY Permit Number: Issue Date: Permit Expires On: D18-0277 10/25/2018 4/23/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: KC HOUSING AUTHORITY 600 ANDOVER PARK W , TUKWILA, WA, 98188 MICHAEL CUADRA 700 ANDOVER PARK W , TUKWILA, WA, 98188 ELTEC SYSTMES LLC 2025 1ST AVE 790, SEATTLE, WA, 98121 ELTECSL023CS KING COUNTY HOUSING AUTHORITY 700 ANDOVER PARK W , TUKWILA, WA, 98188 Phone: (206) 574-1219 Phone: Expiration Date: DESCRIPTION OF WORK: REARRANGE EQUIPMENT IN MACHINE ROOM TO COMPLY WITH ELEVATOR CODE, MISC CUTTING, PATCHING, AND INFILLING TO COMPLY WITH CURRENT ELEVATOR CODE. Project Valuation: $80,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: NO Type of Construction: VA Electrical Service Provided by: TUKWILA Fees Collected: $2,330.65 Occupancy per IBC: R-2 Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: am Water Meter: No Permit Center Authorized Signature: Li Date: iofffY I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: JC0 Date: 102 ( % This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: Insulating materials, where exposed as installed in buildings of any type of construction, shall have a flame spread index of not more than 25 and a smoke development index of not more than 450. Where facings are installed in concealed spaces in buildings of Type III, IV, or V construction, the flame spread and smoke - developed limitations do not apply to facings, that are installed behind and in substantial contact with the unexposed surface of the ceiling, wall or floor finish. 5: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0450 FIRE/SMOKE RESISTANT PEN 0409 FRAMING 0502 LATH/GYPSUM BOARD CITY OF TUK1 A Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Pet No. P1 0' Or' Project No. Date Application Accepted: Date Application Expires: 'v''f'7) v (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 14410 41st Ave S Tenant Name: King County Housing Authority King Co Assessor's Tax No.: 004000-0205 Suite Number: Floor: PROPERTY OWNER Name: Michael Cuadra Name: King County Housing Authority Address: 700 Andover Park W Address: 700 Andover Park W City: Tukwila State: WA City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Michael Cuadra Address: 2025 1st Ave Ste 790 Address: 700 Andover Park W Phone: (206) 405-3371 Fax: City: Tukwila State: WA Zip: 98188 Phone: (206) 574-1219 Fax: City: Seattle State: WA Email: MichaelC@kcha.org Phone: (206) 378-0569 Fax: GENERAL CONTRACTOR INFORMATION Company Name: Eltec Systems LLC Address: 2025 1st Ave Ste 790 City: Seattle State: WA Zip: 98121 Phone: (206) 405-3371 Fax: Contr Reg No.: 601850542 Exp Date: 03/08/2019 Tukwila Business License No.: H:•Applications,Forms-Applications On Line2011 Applications\Permit Application Revised - 8-9-I I .docx Revised: August 2011 bh New Tenant: ❑ Yes ❑✓ .. No ARCHITECT OF RECORD Company Name: SHKS Architects Architect Name: Jonathan Hartung Address: 1050 N 38th St. Cit': Seattle State: WA Zip: 98103 Phone: (206) 675-9151 Fax: Email: levij@shksarchitects.com (levi jette, contact) ENGINEER OF RECORD Name: k11JCp Co4"-)sY ikOuSING AvT110RITV Company Name: Greenbusch Group City: t11y�W%I.R State: WA Zip: 9818f, Engineer Name: Dylan Turner Address: 1900 W Nickerson St City: Seattle State: WA Zip: 98119 Phone: (206) 378-0569 Fax: Email: dylant@greenbusch.com LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: k11JCp Co4"-)sY ikOuSING AvT110RITV Address: City: t11y�W%I.R State: WA Zip: 9818f, Page 1 of 4 I"k BUILDING PERMIT INFORMATIC 206-431-3670 Valuation of Project (contractor's bid price): $ 80,000 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): Rearrange equipment in machine room to comply with elevator code, miscellaneous cutting, patching, and infilling to comply with current elevator code. Will there be new rack storage? ❑ Yes ❑✓ .. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: No Change Compact: No Change Handicap: No Change Will there be a change in use? ❑ Yes No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑✓ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If "yes ; attach list of materials and storage locations, on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: ApplicationsTorms-Applications On Line•201 I Applications\Permit Application Revised - 8-9-11 .docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC lst Floor 6,273 106 0 0 V—A R2 2nd Floor 6,273 14 If 0 0 V—A R2 3`d Floor 6,273 17 If 0 0 V—A R2 Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: No Change Compact: No Change Handicap: No Change Will there be a change in use? ❑ Yes No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑✓ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If "yes ; attach list of materials and storage locations, on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: ApplicationsTorms-Applications On Line•201 I Applications\Permit Application Revised - 8-9-11 .docx Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES - `w Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR prIITHORIZED AGENT: Signature: Print Name: LCV Jerrs Mailing Address: (OS c N. 38"W Sr I-T:`.Applications \Forms -Applications On Line \201 I Applications\Permit Application Revised - 8-9-I I.docx Revised: August 2011 bh Date: 6/51/1 -eq 8 Day Telephone: 2.c4. ^ 4,1-S - 91S I Sl:RT1'L6 City wR 98103 State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $1,442.08 D18-0277 Address: 14410 41ST AVE 5 BLDG 1 Apn: 0040000205 $1,442.08 Credit Card Fee $42.00 Credit Card Fee R000.369.908.00.00 0.00 $42.00 DEVELOPMENT $1,333.72 PERMIT FEE R000.322.100.00.00 0.00 $1,327.22 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $6.50 TECHNOLOGY FEE $66.36 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R15714 R000.322.900.04.00 0.00 $66.36 $1,442.08 Date Paid: Thursday, October 25, 2018 Paid By: MICHAEL CUADRA Pay Method: CREDIT CARD 079426 Printed: Thursday, October 25, 2018 2:52 PM 1 of 1 SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $980.48 D18-0277 Address: 14410 41ST AVE S BLDG 1 Apn: 0040000205 $888.57 Credit Card Fee $25.88 Credit Card Fee R000.369.908.00.00 0.00 $25.88 DEVELOPMENT $862.69 PLAN CHECK FEE R000.345.830.00.00 0.00 $862.69 M18-0113 Address: 14410 41ST AVE S BLDG 1 Apn: 0040000205 $91.91 Credit Card Fee $2.68 Credit Card Fee R000.369.908.00.00 0.00 $2.68 MECHANICAL $89.23 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R15304 R R000.322.102.00.00 0.00 $89.23 $980.48 Date Paid: Friday, August 31, 2018 Paid By: NICHAEL CUADRA Pay Method: CREDIT CARD 096983 Printed: Friday, August 31, 2018 11:05 AM 1 of 1 SYSTEMS c O CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 10/25/2018 02:51:55 PM CREDIT CARD SALE VISA CARD NUMBER: **********8721 K TRAN AMOUNT: $1,442.08 APPROVAL CD: 079426 RECORD #: 000 CLERK ID: Rachelle X {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy Page 1 of 2 http s ://c lassic. convergepay. com/V irtualMerchant/transaction. do?dispatchMethod=printTr... 10/25/2018 F1 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 10/25/2018 02:51:55 PM CREDIT CARD SALE VISA CARD NUMBER: **********8721 K TRAN AMOUNT: $1,442.08 APPROVAL CD: 079426 RECORD #: 000 CLERK ID: Rachelle Thank you! Customer Copy Page 2 of 2 https://classic.convergepay.com/V irtualMerchant/transaction.do?dispatchMethod=printTr... 10/25/2018 Page 1 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 08/31/2018 11:05:25 AM VISA CARD NUMBER: TRAN AMOUNT: APPROVAL CD: RECORD #: CLERK ID: X CREDIT CARD SALE R -E -P -R -I -N -T **********8721 K $980.48 096983 000 Rachelle {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy haps : //c lassic. convergepay. com/V irtualMerchant/transaction. do?di spatchMethod=printTra... 8/31 /2018 Page 2 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 08/31/2018 11:05:25 AM CREDIT CARD SALE R -E -P -R -I -N -T VISA CARD NUMBER: **********8721 K TRAN AMOUNT: $980.48 APPROVAL CD: 096983 RECORD #: 000 CLERK ID: Rachelle Thank you! Customer Copy haps : //clas sic. convergepay .com/VirtualMerchant/transaction.do?dispatchMethod=printTra... 8/31 /2018 Memorandum To: Levi Jette Address: SHKS Architects 1050 N 38`h St Seattle WA, 98103 Project: KCHA Elevator Upgrades Riverton Terrace 01710-2018-01 Date: From: Swenson Say Faget STRUCTURAL ENGINEERING 2124 Third Ave, Suite 100 Seattle, WA 98121 O 206.443.6212 934 Broadway, Suite 100 Tacoma, WA 98402 O 253.284.9470 ssfengineers.com June29,2015 Aaron Lie ber'REVIEWED FOR Staff Eng nCODE COMPLIANCE APPROVED Project Information OCT 2 4 2018 A -J 12.12. City of Tukwila _BUJ' nihn_11-1111c1(14 It is our opinion that special inspection and doweling of rebar are not required for the installation of the new elevator jack. The elevator jack is supported by two vertical channels from the manufacturer that span to bear on the slab on grade. As the area required to be removed is minimal, additional reinforcement, doweling, and accompanying special inspection are not expected to be required. Aaron Lieberman Staff Engineer D 206.956.3746 O 206.443.6212 SWENSON SAY FAGET STRUCTURAL ENGINEERING 2124 Third Avenue, Suite 100, Seattle, WA 98121 ssfengineers.com CORRECTION LTR# RECEIVED CITY OF TUKWILA bi8 0177 OCT 11 2018 PERMIT CENTER 3MTM Fire Protection Products 3MTM Fire Barrier Moldable Putty+ Intumescent firesfop putty that remains moldable for easy re-enterability. 3M'" Fire Barrier Moldable Putty+ is a one -part, ready -to -use firestop designed for wall openings, electrical outlet boxes, cable, conduit and pipes which penetrate fire -rated construction. When properly applied, 3M'" Fire Barrier Moldable Putty+ helps control the spread of fire, smoke and toxic gases through fire -resistive walls and floors. Ti& 3MTM Fire Barrier Moldable Putty+ When used in a through penetration firestop application the 3M"" Fire Barrier Moldable Putty+ intumesces in the annular space to completely surround the penetrant helping to prevent the spread of fire, smoke and toxic gas before, during and after exposure to a fire. The halogen - free, solvent -free formula is non -corrosive and is safe for sensitive electrical equipment. 3M"" Fire Barrier Moldable Putty+ meets ASTM E 814 (UL 1479) requirements for up to a 4 -hour fire -rated system. In addition, these products help reduce sound transmission (STC -Rating of 52 when tested in STC 53 -Rated wall assembly). Features and Benefits • Hand -moldable for easy application (no special tools or damming required) • Low VOC, minimal odor • Easily re -enterable for retrofit applications • Will not dry out or crumble • Formulated without asbestos • Formulated without solvents and halogens • Provides draft and cold smoke seal (L -Rating) • Red color widely recognized as a firestop • Helps reduce sound transmission 3M Building and Commercial Services Division 3M Center Building 223-2N-21 St. Paul, MN 55144-1000 800-328-1687 www.3M.com/firestop 3M" Fire Barrier Moldable Putty Pads MPP+ are typically used as a wall opening protective material to meet building requirements, for protection of membrane penetrations made by listed steel or non-metallic electrical boxes. Ordering Information Product 3M'" Fire Barrier Moldable Putty Pads MPP+ (nom. 1/10" thick) 3M'" Fire Barrier Moldable Putty Stix MP+ 3M'" Fire Barrer Moldable Putty Pads MPP+ o.QSS/Pie LISTED WALL OPENING PROTECTNE FILL VOID OR CAVIry FILL, VOW, OR CAVITY MATERIAL FIRE RESISTANCE MATF_RIALS FOR USE M THROUGH -PENETRATION CLASSFICATION SEE UL ARE goGg FIRESTOP SYSTEMS RESISTANCE DIRECTORY SEE UL RTE RESISTANCE DIRECTORY 9069 I 9069 Size 3M" Fire Barrier Moldable Putty Stix MP+ are typically used to seal gaps between cables in multiple penetrations and to firestop cable bundles, insulated pipe, electrical conduit, metal pipe and other through penetrations. 4" x 8" 7"x7" 9-1/2" x 9-1/2" 1.4"dia. xll" 1.4"dia. x6" (Retail) UPC Units/Box 000-51115-16508-5 000-51115-16509-2 000-51115-16510-8 000-51115-16526-9 10 20 20 10 000-51115-16561-0 12 APPROVED SUBJECT TO THE CONDITIONS OF APPROVAL ASA WALLA FLOOR PENETRATION FIRESTOP WHEN INSTALLED AS DESCRIBED IN THE CURRENT EDITION OF THE FMRC APPROVAL GUIDE 3M Fire Barrier Moldable Putty Stix MP+ usTEU FIRESTOP SYSTEMS SEE INTERTFJ( DIRECTORY Important Notice to User: Technical Information: The technical information, recommendations and other statements contained in this document are based upon tests or experience that 3M believes are reliable, but the accuracy or completeness of such information is not guaranteed. Product Use: Many factors beyond 3M's control and uniquely within user's knowledge and control can affect the use and performance of a 3M product in a particular application. Given the variety of factors that can affect the use and performance of a 3M product, user is solely responsible for evaluating the 3M product and determining whether it is fit for a particular purpose and suitable for user's method of appication. Warranty and Limited Remedy: 3M warrants that each 3M Fire Protection Product will be free from defects in material and manufacture for 90 days from the date of purchase from 3M's authorized distributor. 3M MAKES NO OTHER EXPRESS OR IMPLIED WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If a 3M product does not conform to this warranty, the sole and exclusive remedy is, at 3M's option, replacement of the 3M product or refund of the purchase price. Limitation of Liability: Except where prohibited by law, 3M will not be liable for any loss or damage arising from the 3M product, whether direct, indirect, special, incidental or consequential, regardless of the legal theory asserted. © 3M 2012. All rights reserved. 3M is a trademark of 3M. Used under license in Canada. All Printed in U.S.A. 98-0400-5063-9 REV B Please recycle. other trademarks are the property of their respective owners. co V E L fC a O LL C CL 0 0 .- � C. _O ice+ Q Cr. i) O Cal "Hands down, l would _c use this over an I've used before," The larger the application opening, the greater the time and money savings. c O y 27 -0 O CD � L O E a) a E• _ w O Cable Bundles Conduit Banks Electrical Contractor. J 0) C6 Li e • 0 0 0 O O 9 O 0) C c O O a 0 CD x C6 CD Q o • OQ c CI) a) } con oU o c 0 o' o Q) • c� 0 all C6 C o .5 C 2u.' .� (J) Q o C @ C O E O O • O v; g'- (— C an o U o C a O oG 7:3 vi y ccs -a—_° -c Q.) O O co 0 VJ -�, N o '_ n o 0 0 0)- U L. C CD 1O �' c...0 C '75ll> c z? C 6) Q O O `1 QJ U 05)= = Q C6 U _c)c ad iZ ccs 0 0at .= O CO O U O i a CZ CZ o • .o CZ v 0 .Q o • Q) J CZ Q L rte„ y0 CZ 4O CI) Y. M _ell O cII ) C a 0 0 0.) 0 `te d, Q W 0 0 .0- ;? - F• 0 o- o c a) a O ^_ :=-.0 LL 8 O O C 0 ca (n O N V U Q. -O 0 . '6 c V) � T'"' C • GO v; -- a.) Q. O C1' ax, 0 C O 1 -G O O_ 2, all C) y Q. 5 2 73o .0 O 2 c_ CJ O ersaC5 C O -O all Cr) O 0 • CG C p _ U = a) n C all .� 8 C ca CI, Cr, 0 O - O • (L` N ll = i O O ad ad Ordering Information 3M" FIP 1 -Step Firestop Foam Product Number: FIP 1 -Step Description: Firestop Foam Unit: Cartridge Billing UPC Number: 000-51115-54925-0 Quantity: 1 Price Unit: Each *lull Building and Commercial Services Division 3M Center Building 223-2N-21 St. Paul, MN 55144-1000 1-800-328-1687 www.3M.com/firestopfoam HandyMax® HMS-G4C2 Product Number: HMS-G4C2 Description: Manual Gun Billing UPC Number: 000-51115-54927-4 Quantity: 1 Price Unit Each 3MTM FIP 1 -Step Firestop Foam. It's about time. PowerMax® HPS-4C2 Product Number: HPS-4C2 Description: Battery -Powered Gun Billing UPC Number: 000-51115-54928-1 Quantity: 1 Price Unit: Each Description: Battery Billing UPC Number: 000-51115-54930-4 Quantity: 1 Price Unit: Each Visit www.3M.com/firestopfoam for technical information, UL Listed systems, training information and more, or call 1-800-328-1687. Please recycle. Printed in U.S.A. © 3M 2013. All rights reserved. 3M is a trademark of 3M. PowerMax and HandyMax are registered trademarks of Soraton SA. 98-0213-4665-9 3/1/2019 City of Tukwila Department of Community Development MICHAEL CUADRA 700 ANDOVER PARK W TUKWILA, WA 98188 RE: Permit No. D18-0277 KING COUNTY HOUSING AUTHORITY 14410 41ST AVE S Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 4/23/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 4/23/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: D18-0277 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Department of Community Development September 20, 2018 MICHAEL CUADRA 700 ANDOVER PARK W TUKWILA, WA 98188 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D18-0277 KING COUNTY HOUSING AUTHORITY - 14410 41ST AVE S Dear MICHAEL CUADRA, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x17 to a preferably maximum size of 24x36; all sheets shall be the same size; larger sizes may be negotiable. "New revised" plan sheets shall be the same size sheets as those previously submitted.) "STAMP AND SIGNATURES" (If applicable) For Engineers: "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient (WAC 196-23-010 & 196-23-020). Architects: "date" only not required (WAC 308-12-081). (BUILDING REVIEW NOTES) 1. The plan indicates replacing the elevator jack and filling in with 3000 lb. grout. Provide the required special inspections by an engineer and details of the concrete repairs to include doweling into existing slab and soils test. Special inspections required shall be indicated on the plan sheet. Include engineer's calculations. Refer to STAMP AND SIGNATURES note above. 2. Where the Key Note #22 refers to packing the sealing the door frame with sealant and rockwool, provide specific details showing depth and thickness of the insulation and specifications for sealing with fire putty including type of sealant. 3. Provide specifications for sealing pipe penetrations and repairs to panels removed in the firewall to the elevator shaft. Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 In order to better expedite your resubmittal, a'Revision Submittal Sheet' must accompanytvery resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206)433-7165. Sincerely, (-11411) Rachelle Ripley Permit Technician File No. D18-0277 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 9E2!':]i PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0277 DATE: 10/11/18 PROJECT NAME: KING COUNTY HOUSING AUTHORITY SITE ADDRESS: 14410 41 AVE S Original Plan Submittal X Response to Correction Letter # 1 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: too Building Division Public Works Fire Prevention Structural Planning Division nPermit Coordinator n PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 10/16/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/13/18 Approved Corrections Required Approved with Conditions n ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0277 DATE: 09/05/18 PROJECT NAME: KING COUNTY HOUSING AUTHORITY SITE ADDRESS: 14410 41ST AVE S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: AT Co,v Sa Building Division III PI Public Works kvi 0/4. Fire Prevention 111 Structural 111 Ok/ 61111 Planning Division II Permit Coordinator n PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: 09/06/18 Structural Review Required DATE: El APPROVALS OR CORRECTIONS: Approved Corrections Required El (corrections entered in Reviews) DUE DATE: Approved with Conditions Denied (ie: Zoning Issues) 10/04/18 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: '116 Bldg Fire 0 Ping 0 PW ❑ Staff Initials: r- 1 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 10/4/2018 D18-0277 Plan Check/Permit Number: ❑ Response to Incomplete Letter # ® Response to Correction Letter # _1_ ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # RECEIVED CITY OF TUKWILA OCT 1 1 2018 PERMIT CENTER Project Name: KING COUNTY HOUSING AUTHORITY Project Address: 14410 41ST AVE S Levi Jetta Contact Person: Phone Number: 206-224-3317 Summary of Revision: 1. See attached letter from the structural engineer regarding the scope of work at the elevator jack replacement and slab repair. The work's limited scope requires no reinforcement or special inspections. 2. Please see additional detail 3/A2.2. Per IEBC 703.1, an alteration level 1 must maintain the level of fire protection provided. The work at the door is not a code required improvement, only a consultant recommended imrpovement. 3. See keynotes 4, 5, and 25 on sheet A2.1, edited to clarify that infill is to match existing wall being infilled. Pipe penetrations to be sealed per existing detail 3/M0.1, specified with either 3M fire barrier rated Foam FIP 1 -step, 3M fire barrier moldable putty, or an approved equal. See attached cut sheets. Sheet Number(s): A2.1, A2.2 "Cloud" or highlight all areas of revision including date of revisit Received at the City of Tukwila Permit Center by: Entered in TRAKiT on 10--((--c0 W.1Pcrmit Center (Brenda)\Formstpermit Center Documents (Word)'Rcvision Submittal Form doc Revised August 2015 Hoine Espanol Contact. Safety & Health Claims & Insurance Washington State Department of Labor & Industries Search L&I A -Z Index Help My L&1 Workplace Rights Trades & Licensing ELTEC SYSTEMS LLC Owner or tradesperson Principals FERGUSON, GORDON WAYNE, PARTNER/MEMBER TAPLIN, DANIEL SHERMAN, PARTNER/MEMBER STEWART, DAVID, AGENT Doing business as ELTEC SYSTEMS LLC WA UBI No. 601 850 542 2025 1ST AVE STE 790 SEATTLE, WA 98121 206-405-3371 KING County Business type Limited Liability Company Governing persons GORDON WAYNE FERGUSON DANIEL S TAPLIN; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. ELTECSL023C3 Effective — expiration 02/23/1998— 03/08/2019 Bond Developers Surety & Indem Co Bond account no. 510064C $12,000.00 Received by L&I Effective date 03/06/2015 01/25/2010 Expiration date Until Canceled Insurance Great American Alliance Insura $1,000,000.00 Policy no. GLP132434900 Received by L&I Effective date 02/28/2018 03/01/2017 Expiration date 03/01/2019 Insurance history Help us improve Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 953,216-00 Doing business as ELTEC SYSTEMS LLC Estimated workers reported Quarter 2 of Year 2018 "Greater than 100 Workers" L&I account contact T5 / MARVIN GREEN (360)902-4967 - Email: GRMB235©Ini.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. © Washington State Dept. of Labor & Industries. Use of this site is subject to ttie laws of the state of Washington. Help us improve ABBREVIATIONS L (E) A.B. ABV AC ACT ACU ADJ AFF ALT ALUM APPROX BLDG BLW B.O. CB CBB CEM CJ CL CLG CLR CO COL CONC COND CONT CPT CT DBL DEMO DF DIA DIFF DIM DISP DN DR DS DTL DW E EA ECS EF EJ EL ELEC ELEV EMERG EQ EXP FBP FD FE FF FH FIN FLR F.O. FOIC F010 FR FS AND ANGLE AT DIAMETER POUND OR NUMBER EXISTING CENTERLINE ANCHOR BOLT ABOVE AIR CONDITIONING ACOUSTIC CEILING TILE AIR CONDITION UNIT ADJUSTABLE ABOVE FINISHED FLOOR ALTERNATE ALUMINUM APPROXIMATELY BUILDING BELOW BOTTOM OF CATCH BASIN CEMENT BACKER BOARD CEMENT CONTROL JOINT CENTERLINE CEILING CLEAR CLEAN OUT COLUMN CONCRETE CONDITION CONTINUOUS CARPET CERAMIC TILE DOUBLE DEMOLISH DRINKING FOUNTAIN DIAMETER DIFFUSER DIMENSION DISPENSER DOWN DOOR DOWNSPOUT DETAIL DISHWASHER EAST EACH EXTERIOR COMPOSITE SIDING EXHAUST FAN EXPANSION JOINT ELEVATION ELECTRICAL ELEVATOR EMERGENCY EQUAL EXPANSION FIBER BOARD PANEL FLOOR DRAIN FIRE EXTINGUISHER FINISH FLOOR FIRE HYDRANT FINISH FLOOR FACE OF FURNISHED BY OWNER, INSTALL BY CONTRACTOR FURNISHED BY OWNER INSTALL BY OWNER FIRE RESISTANT FLOOR SINK MATERIAL SYMBOLS BATT INSULATION EARTH MASONRY GA GALV GB GL GLB GND GR GRT'D GWB HB HC HCMU HDWD HDWE HT HM HR HORIZ I.D. INSUL INT JAN JT KIT LAB LAM LAV LKR LOC LT LVL M MATL MAX MC MECH MEMB MFR MIN MIR MISC MH MO MTD MTL MULL N NA NIC NOM NTS NR OA OBS O.C. O.D. OFF OPNG OPP PC PL PLAS PLY P.LAM PNT POC PR PSL PT PTN 0 p e ch p0�OXTOp N/1/1/1/1NN/ /1/1/NON /NON N/ /1/1/1/\/1/1/1/ /1/1/1/1/1/1/1/ /1/1/1/1/1/1/1/ /1/1/1/1/1/1/1/ 0 010101 N 10 GAUGE GALVANIZED GRAB BAR GLASS GLU-LAM BEAM GROUND GRADE GROUTED GYPSUM WALL BOARD HOSE BIBB HANDICAP HOLLOW CLAY MASONRY UNIT HARDWOOD HARDWARE HEIGHT HOLLOW METAL HOUR HORIZONTAL INSIDE DIAMETER INSULATION INTERIOR JANITOR JOINT KITCHEN LABORATORY LAMINATE LAVATORY LOCKER LOCATE LIGHT LAMINATED VENEER LUMBER MEN'S MATERIAL MAXIMUM MEDICINE CABINET MECHANICAL MEMBRANE MANUFACTURER MINIMUM MIRROR MISCELLANEOUS MANHOLE MASONRY OPENING MOUNTED METAL MULLION NORTH NOT APPLICABLE NOT IN CONTRACT NOMINAL NOT TO SCALE NOT RATED OVERALL OBSCURE ON CENTER OUTSIDE DIAMETER OFFICE OPENING OPPOSITE PRECAST CONCRETE PLATE PLASTER PLYWOOD PLASTIC LAMINATE PAINT POINT OF CONNECTION PAIR PARALLEL STRAND LUMBER PRESSURE TREATED PARTITION CONCRETE GRAVEL PLYWOOD QT R or RAD RB RCP RD REF REFR REINF RELOC REQ'D RES RM RO RV RL S SA SC SCHED SECT SG SHT SIM SPEC SQ S.S. STA STD STL STN STOR STRUCT SOG SUSP SYM T, TMP T&G TEL TER THK T.O. TS TV TYP UL UNO VCT VERT VEST VIF VTR W W/ WC WD WF W/O WOM WM WP WR WSCT WT • .w.w... 1 i~$ g. •r r., . APR 23 2Q QUARRY TILE RADIUS RESILIENT BASE REFLECTED CEILING PLAN ROOF DRAIN REFERENCE REFRIGERATOR REINFORCED RELOCATE REQUIRED RESILIENT ROOM ROUGH OPENING ROOF VENT RAIN WATER LEADER SOUTH SMOKE ALARM SOLID CORE SCHEDULE SECTION SAFETY GLASS SHEET SIMILAR SPECIFICATION SQUARE STAINLESS STEEL STATION STANDARD STEEL STAIN STORAGE STRUCTURE SLAB ON GRADE SUSPENDED SYMMETRICAL TEMPERED TONGUE & GROOVE TELEPHONE TERRAllO THICK TOP OF TUBE STEEL TELEVISION TYPICAL UNDERWRITERS' LABORATORIES UNLESS NOTED OTHERWISE VINYL COMPOSITION TILE VERTICAL VESTIBULE VERIFY IN FIELD VENT THRU ROOF WEST WITH WATER CLOSET WOOD WIDE FLANGE WITHOUT WALK OFF MAT WOMEN'S WATERPROOFING WATER RESISTANT WAINSCOT WEIGHT RIGID INSULATION WOOD STEEL DRAFTING SYMBOLS ROOM NAME 101 NAME 41, ELEVATION XXX T.O. XXX -R - - DESCRIPTION TJ� WALL SECTION BLDG SECTION EXTERIOR ELEVATION INTERIOR ELEVATION DETAIL NORTH ARROW GRID HEAD ROOM TAG WINDOW TAG WALL TAG DOOR TAG KEY NOTE ELEVATION NOTE SPOT ELEVATION CENTERLINE PROPERTY LINE FLOOR TRANSITION REVISION BREAKLINE DIMENSION POINT DETAIL BORDER VICINITY MAP Bryn Mawr -Skyway 8128th S 144th St slam 155th St Tukwila `Family: Fun Center &.,. Seattle -Tacoma international Airport Crowne Plaza Seattle Airport 81%681M SeaTac Or GENERAL NOTES -•ss OriIiia sjnamst s 180th St ' 167 IKEA Renton Home Furnishings PROJECT LOCATION: 14410 41ST AVE S TUKWILA, WA 98169 1. CONTRACTOR SHALL VERIFY CONDITIONS AND DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. NOTIFY THE ARCHITECT OF ANY CONDITIONS INCONSISTENT WITH THE INTENT OF THE DRAWINGS PRIOR TO STARTING OR CONTINUING WORK IN THE AREA CONCERNED. CODE: 1. ALL WORK SHALL CONFORM TO APPLICABLE CODES AND LOCAL BUILDING REQUIREMENTS, WHICH INCLUDE THE MOST CURRENT EDITIONS OF THE INTERNATIONAL BUILDING CODE WITH LOCAL AMENDMENTS, INTERNATIONAL MECHANICAL CODE (IMC), NATIONAL ELECTRICAL CODE (NEC), INTERNATIONAL FIRE CODE (IFC), AND WASHINGTON STATE ENERGY CODE (WEC). 2. MECHANICAL, ELECTRICAL AND PLUMBING PERMITS TO BE APPLIED FOR UNDER SEPARATE APPLICATION BY CONTRACTOR. 3. PER IEBC 503.1, ALL WORK IS CLASSIFIED AS AN ALTERATION LEVEL 1 REMOVAL OR REPLACEMENT OF EXISTING MATERIALS, ELEMENTS, EQUIPMENT, OR FIXTURES USING NEW MATERIALS, ELEMENTS, EQUIPMENT, OR FIXTURES THAT SERVE THE SAME PURPOSE. PER IEBC 701.2, AN EXISTING BUILDING SHALL NOT BE ALTERED SUCH THAT THE BUILDING BECOMES LESS SAFE THAN ITS EXISTING CONDITION. DEMOLITION: 1. WHERE ITEMS ARE INDICATED ON PLANS TO BE DEMOLISHED, IT SHALL MEAN THE COMPLETE REMOVAL AND DISPOSAL OF THE ITEM INDICATED UNLESS OTHERWISE NOTED. CONTRACTOR IS RESPONSIBLE FOR REVIEW OF THE HAZARDOUS MATERIALS ABATEMENT, ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR CUTTING AND PATCHING WORK. DIMENSIONS: 1. DO NOT SCALE DRAWINGS. 2. VERIFY DIMENSIONS SHOWN ON DRAWINGS. USE ONLY DIMENSIONS INDICATED. PRIOR TO STARTING OR CONTINUING WORK, NOTIFY ARCHITECT OF DISCREPANCIES OR CONDITIONS INCONSISTENT WITH THE INTENT OF THE CONSTRUCTION DOCUMENTS. 3. DIMENSIONS ARE TO FACE OF CONCRETE, FACE OF MASONRY, OR FACE OF STUD, UNLESS OTHERWISE NOTED. 4. FINISHED SURFACE OF INFILL OR EXTENSIONS OF EXISTING PARTITIONS SHALL ALIGN WITH ADJACENT EXISTING SURFACES UNLESS OTHERWISE NOTED. 5. VERTICAL DIMENSIONS ARE MEASURED FROM STRUCTURAL SLAB, TOP OF STEEL OR TOP OF SHEATHING, UNLESS NOTED OTHERWISE. COORDINATION: 1. COORDINATE ALL OPERATIONS WITH OWNER, SUCH AS AREAS USED FOR MATERIAL STORAGE, ACCESS TO AND FROM THE SITE, TIMING OF WORK AND REQUIREMENTS OF NOISE ORDINANCE. INSTALL DUST AND NOISE BARRIERS AS REQUIRED TO PROTECT EXISTING ADJACENT BUILDINGS AND OCCUPANTS AND TO MAINTAIN AN ENVIRONMENT SUITABLE TO PERMIT CONTINUED OCCUPANCY OF SUBJECT AND ADJACENT BUILDINGS. 2. VERIFY LOCATIONS OF EXISTING UTILITIES. CAP, MARK AND PROTECT AS NECESSARY TO COMPLETE THE WORK. 3. PIPING, CONDUITS, DUCTS, ETC. SHALL BE CONCEALED IN WALLS, CHASES, ABOVE SUSPENDED CEILINGS, BELOW FLOORS OR BE FURRED -IN IN ROOMS WITH EXISTING CEILINGS, UNLESS OTHERWISE NOTED. DO NOT CONCEAL PIPING, CONDUITS, DUCTS, ETC. IN ELECTRICAL, MECHANICAL, AND COMMUNICATION ROOMS. 4. COORDINATE ANY FIRE ALARM AND SECURITY ALARM DISCONNECTS AT COMMON AREA DOORS WITH OWNER. 5. COORDINATE AND PROVIDE REQUIRED PENETRATIONS AND PATCHING WITH INDIVIDUAL SUBCONTRACTORS TO SUIT NEW WORK. 6. "REMOVE" MEANS TO COMPLETELY AND PERMANENTLY REMOVE FROM THE PROJECT. ,APs r 3 204 S E. PA , i L. I i •7I I , r'. iFIED FOR: t�1 ��chanicai [dlcctrical umbing E2 Cas Piping City of Tukwila DiViSION SOUTH 144TH STREET SOUTH 146TH STREET FILE COPY Permit °'o. P1'6' 611 Plan review approval is subj ct to errors and omicsions. Approval of co istruct:o n dmmicnts Geos I Gi u: ionize the violation of any adopted co ',a or ordirianca. I `cco!pt of approved Field Copy and condi io os is acl�t �o vledged: By: Date: le, in 5/19t City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work with(!.! prior approval of Tukwila Building Division N3TE: Revisions will require a new plan submittal and may include additional Flan review tec;s SHKSARCHITECTS PROJECT INFORMATION PROJECT OWNER: KING COUNTY HOUSING AUTHORITY PROJECT MANAGER: LISA HAWKINS TEL: 206.574.1167 EMAIL: lisaha@kcha.org PROJECT ADDRESS: 14410 41ST AVE S TUKWILA, WA 98188 SCOPE DESCRIPTION: MODERNIZE (1) HYDRAULIC ELEVATOR, REARRANGE EQUIPMENT IN MACHINE ROOM TO COMPLY WITH ELEVATOR CODE, ADD MINOR ELECTRICAL IMPROVEMENTS TO BRING ELEVATOR POWER UP TO CURRENT CODE, AND MISCELLANEOUS CUTTING AND PATCHING. THERE ARE NO CODE UPGRADES WITH THIS ELEVATOR MODERNIZATION SUCH AS INCREASING FIRE RATINGS OR OTHER GENERAL WORK. DESIGN TEAM ARCHITECT: SHKS ARCHITECTS 1050 NORTH 38TH ST SEATTLE, WA 98103 TEL: 206.675.9151 CONTACT: LEVI JETTE EMAIL: levij@shksarchitects.com STRUCTURAL ENGINEER: SWENSON SAY FAGET 1200 WESTLAKE AVE N SUITE 509 SEATTLE, WA 98109 TEL: 206.9 6.3736 CONTACT: ANE KANYER EMAIL: zkanyer@ssfengineers.com ZONING ANALYSIS PARCEL NUMBER: 004000-0205 MECHANICAL ENGINEER: GREENBUSCH GROUP 1900 W NICKERSON ST SEATTLE, WA 98119 TEL: 206.378.0569 x112 CONTACT: DYLAN TURNER EMAIL: dylant@greenbusch.com ELECTRICAL ENGINEER: TRAVIS FITZMAURICE & ASSOCIATES 1200 WESTLAKE AVE N SUITE 509 SEATTLE, WA 98109 TEL: 206.413.5013 CONTACT: ROCXY JUAN EMAIL: rocxy@travisfitzmaurice.com LEGAL DESCRIPTION: ADAMS HOME TRS LOT 1 OF AMENDED TUKWILA SP #L06-091 REC 20090219900002 SD SP DAF - E 3 FT OF LOT 15 TGW LOT 16 BLK 2 OF SD PLAT LESS POR FOR RD PER DEED REC# 20160331001818 LOT AREA: 22750 SF / .52 ACRES ZONE: HDR CURRENT USE: MULTI -FAMILY CONSTRUCTION: WOOD FRAME, SPRINKLED YEAR BUILT: 1969 (E) BLDG AREA: 18,819 SF GROSS / 13,059 SF NET STORIES: 3 PARKING QUANTITY: NO CHANGE REQUIRED SETBACKS: NO CHANGE APPLICABLE CODES 2015 INTERNATIONAL RESIDENTIAL CODE 2015 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL EXISTING BUILDING CODE 2015 INTERNATIONAL MECHANICAL CODE 2015 INTERNATIONAL ENERGY CONSERVATION CODE, RESIDENTIAL 11, COMMERCIAL, WITH WASHINGTON STATE AMENDMENTS 2015 UNIFORM PLUMBING CODE 2015 INTERNATIONAL FIRE CODE 2015 INTERNATIONAL FUEL GAS CODE ALL CODES ADOPTED AND AMENDED BY THE BUILDING CODE COUNCIL IN CHAPTER 51 1050 N.38th St. - Seattle, WA 98103 - PH: 206.675.9151 - www.shksarchitects.com 5158 REGISTERED ARC ITECT JONATHAN H. HA STATE 'OF WASHI Ar';Zi f 29,r, CODE ii-Oi V E t7 F O iR sr DE CO'PLIANCE W APPROVED SHEET INDEX T1.0 COVER SHEET A2.1 FLOOR PLANS & WALL TYPES A2.2 FLOOR PLANS & DETAILS A2.3 INTERIOR ELEVATIONS M1.0 ABBREVS., LEGEND, DRAWING INDEX, GENERAL NOTES, HP LOAD CALCULATION, SCEHDULES AND MECHANICAL DETAILS MD2.1 ELEVATOR LANDING AND MACHINE ROOM MECHANICAL DEMOLITION FLOOR PLANS MD2.2 ELEVATOR LANDING AND ROOF MECHANICAL DEMOLITION FLOOR PLANS M2.1 ELEVATOR LANDING AND MACHINE ROOM MECHANICAL FLOOR PLANS EVD2.1 ELEVATOR LANDING AND ROOF ELEVATOR DEMOLITION FLOOR PLANS EVD2.2 ELEVATOR LANDING AND ROOF ELEVATOR DEMOLITION FLOOR PLANS EV2.1 ELEVATOR LANDING AND MACHINE ROOM ELEVATOR FLOOR PLANS EV2.2 ELEVATOR LANDING AND ROOF ELEVATOR FLOOR PLANS EV2.3 ELEVATOR DIAGRAMS E1.0 LEGENDS, SCHEDULES & DETAILS - ELECTRICAL ED2.0 DEMOLITION FLOOR PLAN - ELECTRICAL E2.0 FLOOR PLANS - ELECTRICAL OCT 24 2018 City of Tukwila BUILDING DIVISION i King County Housing Authority KCHA RIVERTON TERRACE 11 ELEVATORS PERMIT SET 14410 41ST AVE S - TUKWILA, WA 98169 Drawn by: Checked: Date: Scale: - Revisions: No. Date LJ AH 8/27/2018 As indicated Remarks RECEIVED CITY OF TUKWILA AUG 31 2018 - PERMIT CENTER COVER SHEET = T1.0 10/4/2018 4:31:24 PM KEYNOTE LEGEND MARK 1 2 6 9 11 12 13 14 15 16 KEYNOTE TEXT SAND SMOOTH, CLEAN, PREP, AND PAINT (E) ELEVATOR DOORS AND FRAMES PATCH AND REPAIR GWB 6" AROUND EACH HALL FIXTURE CUT AND PATCH (E) CHAIR RAIL TO ACCOMODATE HALL STATIONS DEMO (E) LOUVER, INFILL (E) 14" W x 30" H OPENING TO MATCH ADJACENT WALL AND MAINTAIN THE EXISTING LEVEL OF FIRE PROTECTION DEMO (E) LOUVER, INFILL (E) 14" W x 30" H OPENING TO MATCH ADJACENT WALL AND MAINTAIN THE EXISTING LEVEL OF FIRE PROTECTION AND INSTALL CHAIR RAIL TO MATCH AND FIT ADJACENT DEMO (E) 9" x 12" CEILING VENT, INFILL (E) OPENING HEAT PUMP ON SLEEPERS, EXTERIOR, REFER TO MECHANICAL WALL MOUNT HEAT PUMP, INTERIOR, REFER TO MECHANICAL REFRIGERANT LINES, CUT AND PATCH AT ALL PENETRATIONS, REFER TO MECHANICAL ROUTE REFRIGERANT LINES ABOVE (E) DROP CEILING THERMOSTAT, REFER TO MECHANICAL HYDRAULIC POWER UNIT, REFER TO ELEVATOR CONTROLLER, REFER TO ELEVATOR KEYNOTE LEGEND MARK KEYNOTE TEXT 17 LIGHT SWITCH, REFER TO ELECTRICAL 18 DISCONNECT, REFER TO ELECTRICAL 19 LIGHT FIXTURE, REFER TO ELECTRICAL 20 DEMO (E) ELEVATOR JACK, REPAIR (E) VAPOR BARRIER BELOW SLAB AND INSTALL ELEVATOR JACK. INFILL (E) SLAB WITH 3000 PSI NON -SHRINK GROUT, REFER TO ELEVATOR 22 PACK ELEVATOR DOOR FRAME WITH ROCK WOOL AND SEAL WITH FIRE PUTTY ON HOISTWAY SIDE TAPE AND FINISH DAMAGED GWB IN HOISTWAY DEMO (E) LOUVERS, INFILL (E) 14" W x 30" H OPENING AT WALL TO MATCH ADJACENT WALL AND MAINTAIN THE EXISTING LEVEL OF FIRE PROTECTION, INSTALL WOOD PANEL TO MATCH (E) CABINET AT CASEWORK 26 DEMO (E) 48" x 481" PLYWOOD SHEET BEHIND (E) CONTROLLER 27 CONCEAL VERTICAL REFRIGERANT LINES IN WALL CAVITY 28 ENCLOSE VERTICAL WATER LINES 29 REPLACE MISSING BASE MOULDING DOOR SCHEDULE MARK SIZE DOOR FRAME/TRIM FIRE RATING HW GROUP REMARKS W H TYPE MATERIAL FINISH MATERIAL FINISH 101 3' - 0" 6' - 8" 1 MTL PNT MTL PNT 60 MIN 1 UNIT LOBBY - 7'-8"CLG HT E3 (E) MAILBOXES + CV cD ED z UNIT FIRST FLOOR PLAN APR 2813 (E) HOSITWAY 1 HR RATED, VIF, PER IEBC 704.1 ALTERATIONS SHALL BE DONE IN A MANNER THAT MAINTAINS THE LEVEL OF FIRE PROTECTION PROVIDED E2 1/4" = 1'-0" WALL TYPE El ti EQ (E) 8" CIP WALL, VIF • 8" CONCRETE / EQ E2 cU w cL LU II MACHINE ROOM RCP 1/4" = 11-0" ti (E) 2x4 WOOD FRAMED EXTERIOR WALL, VIF • LAP SIDING • 5/81" T&G SIDING • 1/21" GWB • 2x4 WOOD FRAMING @ 16"0.C. • 5/8" GWB Zo N RR E3 (E) 2x4 WOOD FRAMED INTERIOR WALL, VIF • GWB • 2x4 WOOD FRAMING @ 16" O.C. • GWB • TPO ROOFING MEMBRANE @ EXTERIOR 10'-0"+/- • 9'-5"+/- 4 2 -HR RATED SHAFT WALL, PER UL U415 • (2) LAYERS 1/2" GWB • 2 1/2" C -H STL STUD, 25 GA @ 24" O.C. • 11" GYP LINER PANEL LU co Q MAINTENANCE ELEC LEGEND (E) WALL WALL 2 HR RATED, VIF 0 1 HR RATED, VIF EQUIP (E) HOSITWAY 1 HR RATED, VIF, PER IEBC 704.1 ALTERATIONS SHALL BE DONE IN A MANNER THAT MAINTAINS THE LEVEL OF FIRE PROTECTION PROVIDED 7'-81"+/- 10'-11/211+/- 0 0 LAUNDRY 14' - 7 1/2" +/- E3 27' - 4" +/- COMMUNITY ROOM --- 7' - 0" CLG HT (E) 61" CLEAR ABOVE DROP CEILING PAINT T 0) SO E3 MACHINE 7'-91/2"CLG HT PAINT LOBBY -S- 7' -1 1/2" CLG HT APR 23 2W. BASEMENT 1/4" = 11-0" E2 U 22' -6"+/- RR FEV! VVED FOR E MPLIANCE APPROVED OCT gF X2018 City of Tukwila BUILDING DIVISION b19 0 PAINT 8 CORRECTION LTR# RECEIVED CITY OF TUKWILA OCT 11 2018 PERMIT CENTER 0i7 16 SHKSARCHITECTS El 1050 N.38th St. Seattle, WA 98103 PH: 206.675.9151 www.shksarchitects.com 5158 REGISTERED ARC ITECT JONATHAN H. HA STATF 'OF WASHI King County Housing Authority KCHA RIVERTON TERRACE II ELEVATORS PERMIT SET 14410 41ST AVE S — TUKWILA, WA 98169 Drawn by:. Checked: Date: Scale: — Revisions: No. Date _ 1 10/4/2018 LJ AH 8/27/2018 As indicated Remarks Permit Revision FLOOR PLANS & - WALL TYPES = A2.1 2 10/4/2018 4:31:24 PM KEYNOTE LEGEND MARK KEYNOTE TEXT 1 SAND SMOOTH, CLEAN, PREP, AND PAINT (E) ELEVATOR DOORS AND FRAMES 2 PATCH AND REPAIR GWB 6" AROUND EACH HALL FIXTURE 3 CUT AND PATCH (E) CHAIR RAIL TO ACCOMODATE HALL STATIONS 22 PACK ELEVATOR DOOR FRAME WITH ROCK WOOL AND SEAL WITH FIRE PUTTY ON HOISTWAY SIDE 24 INFILL (E) 12" W x 18" H HOISTWAY VENT OPENING, REPAIR AND PATCH TO MATCH (E) TPO ROOFING ti • (E) GWB COMPLETELY FILL OPENING WITH FIRE -BARRIER RATED SEALANT, MIN THICKNESS 1/2" FILL (E) MTL ELEVATOR DOOR JAMB COMPLETELY WITH NON- COMBUSTIBLE SEMI-RIGID INSULATION NOTE: ELEVATOR DOOR HEAD SHOWN FOR REFERENCE, ELEVATOR DOOR JAMB DETAIL SIM IMPROVEMENT AT ELEVATOR DOOR HEAD (E) ROOF ANCHOR (E) PENTHOUSE VENT, ABANDONED T E3 (E) HOSITWAY 1 HR RATED, VIF, PER IEBC 704.1 ALTERATIONS SHALL BE DONE IN A MANNER THAT MAINTAINS THE LEVEL OF FIRE PROTECTION PROVIDED UNIT LOBBY -$-7'-6"CLGHT CID UNIT O • AR 2821Ia SECOND FLOOR PLAN 7 (E) STAIRS SHKSARCHITECTS RECEIVED CITY OF TUKWILA OCT 11 2018 PERMIT CENTER `JIEVVED FOR CODE COMPLIANCE APPROVED OCT 242018 City of Tukwila BUILDING DIVISION 0 4 8 16 (I) Zeri E21 1050 N.38th St, Seattle, WA 98103 PH: 206.675.9151 www.shksarchitects.com 5158 REGISTERED ARC TECT /9 JONATHAN 11. HA STATE OF WASHI King County Housing Authority KCHA RIVERTON TERRACE II ELEVATORS PERMIT SET 14410 41ST AVE S - TUKWILA, WA 98169 Drawn by:. Checked: Date: Scale: — Revisions: No. Date LJ AH 8/27/2018 As indicated Remarks 1 10/4/2018 Permit Revision FLOOR PLANS & DETAILS = A2.2 8129/2018 9:08:07 AM ,PR 2 3 20 0,1 8' -1"+/ - EQ EQ EQ CAR INTERIOR — RCP 3/4" = 1'-0" 14 GA ELEVATOR WALL 3/4" LAMINATE WALL PANEL PIANO HINGE \ 3.. 7\ FIXED EDGE (2) LAYERS 3/4" PLYWOOD, LAMINATE FINISH 22;222 »2222222»2;»] 222�»»»»»»> 10" L4X2X1/4 CONTINUOUS ANGLE PAN HEAD SCREW, MAX 18" 0.C. BLOCKING BENCH ATTACHMENT DETAIL 3" = 1-0" QSECOND FLOOR INTERIOR ELEVATION Q FIRST FLOOR INTERIOR ELEVATION 3/4" = 1'-0" 8 3/4" = 1-0" HALL LANTERN 1—o— ADA JAMB PLATES ♦ L • POSITION INDICATOR, CALL BUTTONS, AND FIRE SIGNAGE PAINT DOORS] AND JAMBS MEASURED TO RAISED CHARACTER BASELINE (E) HARD LID CLG (E) SOFFIT (E) WD RAIL (E) WD BASE APR 23211T LED LIGHT, TYP, 1 VM \ 1, O CAR OPERATING . + REF ELECTRICAL O CAR EXHAUST FAN, \ \ / // /// REF ELEVATOR + o ti PANELS I � HANDRAIL I L S.S. PAN CEILING O i i ,- O \ 11 O a co CAR INTERIOR — RCP 3/4" = 1'-0" 14 GA ELEVATOR WALL 3/4" LAMINATE WALL PANEL PIANO HINGE \ 3.. 7\ FIXED EDGE (2) LAYERS 3/4" PLYWOOD, LAMINATE FINISH 22;222 »2222222»2;»] 222�»»»»»»> 10" L4X2X1/4 CONTINUOUS ANGLE PAN HEAD SCREW, MAX 18" 0.C. BLOCKING BENCH ATTACHMENT DETAIL 3" = 1-0" QSECOND FLOOR INTERIOR ELEVATION Q FIRST FLOOR INTERIOR ELEVATION 3/4" = 1'-0" 8 3/4" = 1-0" HALL LANTERN 1—o— ADA JAMB PLATES ♦ L • POSITION INDICATOR, CALL BUTTONS, AND FIRE SIGNAGE PAINT DOORS] AND JAMBS MEASURED TO RAISED CHARACTER BASELINE (E) HARD LID CLG (E) SOFFIT (E) WD RAIL (E) WD BASE APR 23211T CAR INTERIOR — FRONT ELEVATION -I 3/4" = 1'-0" 10" + co (E) SIGNAGE r` ca co (E) HARD LID CLG HALL LANTERN FIRE DEPT KEY BOX ADA JAMB PLATES INTERCOM (E) THERMOSTAT (E) HAND SANITIZER DISPENSER POSITION INDICATOR, CALL BUTTONS, AND FIRE SIGNAGE PAINT DOORS" AND JAMBS SHKSARCHITECTS 8 -1 +/- i. — r \ \I BUILT-IN BENCH,' OPERABLE PVC FLOOR / / / 1' - 5" at, i 1 f CAR OPERATING STATION � \ \ / // /// \ / / / + o ti PANELS I � HANDRAIL I ( M I I I I CAR INTERIOR — FRONT ELEVATION -I 3/4" = 1'-0" 10" + co (E) SIGNAGE r` ca co (E) HARD LID CLG HALL LANTERN FIRE DEPT KEY BOX ADA JAMB PLATES INTERCOM (E) THERMOSTAT (E) HAND SANITIZER DISPENSER POSITION INDICATOR, CALL BUTTONS, AND FIRE SIGNAGE PAINT DOORS" AND JAMBS SHKSARCHITECTS 8 -1 +/- i. — r \ \I BUILT-IN BENCH,' OPERABLE PVC FLOOR / / / 1' - 5" M C2CAR INTERIOR — PLAN 3/4" = 1'-0" at, i 1 o F— � \ \ / // /// \ / / / \) / PANELS I � HANDRAIL I ( M M C2CAR INTERIOR — PLAN 3/4" = 1'-0" CARIINTERIOR — SIDE ELEVATION (E) DROP CLG - (E) SIGNAGE i i (E) WD RAIL (E) WD BASE i + 0 APR 2 at, i o F— � I / I / PANELS I � HANDRAIL I ( M I I I I BUILT-IN BENCH, OPERABLE / 1 // I 1 \\(/ co I I \ LI L EQ 1 REY?iEVVE`D i _011 EQ EQ EQ CODE COMPLIANCE / dk CARIINTERIOR — SIDE ELEVATION (E) DROP CLG - (E) SIGNAGE i i (E) WD RAIL (E) WD BASE i + 0 APR 2 CAR1I NTERIOR — REAR ELEVATION + ti ,,, i__ at, i PANELS HANDRAIL � / n I \ I I I BUILT-IN BENCH, OPERABLE ( M I I I I co (E) DROP CLG EQ L EQ 1 CAR1I NTERIOR — REAR ELEVATION + ti ,,, i__ at, i � / n I \ HALL LANTERN (E) DROP CLG REY?iEVVE`D i _011 CODE COMPLIANCE FIRE DEPT KEY BOX APPROVED --.— ADA JAMB PLATES MEASURED TO RAISED CHARACTER BASELINE 1 1 OCT 2 4 2018 City of Tukwil POSITION INDICATOR, BUILDING DIVISION 42" AFF fe CALL BUTTONS, AND FIRE SIGNAGE + N V x m (E) WD RAIL 7-- PAINT DOORS" AND JAMBS co (E) WD BASE BASEMENT INTERIOR ELEVATION 3/4" = 1'-0" 1050 N.38th St. Seattle, WA 98103 — PH: 206.675.9151 - www.shksarchitects.com 5158 REGISTERED ARC ITECT JONATHAN H. HA STATE OF WASHI King County Housing Authority KCHA RIVERTON TERRACE 11 ELEVATORS PERMIT SET 14410 41ST AVE S — TUKWILA, WA 98169 Drawn by: LJ Checked: AH Date: 8/27/2018 Scale: As indicated — Revisions: _ No. Date Remarks RECEIVED - CI -I -Y OF TUKWILA - AUG 31 2018 _ PERMIT CENTER INTERIOR ELEVATIONS = A2.3 ABBREVIATIONS LEGEND DRAWING INDEX AC ACU AD AFF APPROX ARCH ASHRAE BDD BFF BTUH CD CFM CIRC CO COND CONT COORD COTG CW DEG DIA DIM DN DWG E EA ELEV, EL EAT EG ESP EWT EXIST EXH EXP F FCO FD FDC FLA FPM FT G GA GAL GALV GPM GWB HP HVAC HW HWC HWR HWS ID IE IN KW LAT LWT MAX MBH MCA MFG MIN M TG NC NIC NFPA NG NO NTS OA OAT OC OBD ORD OS&Y PH POC PSI RA RL RD REF REQD RG RPM RPBP RS SA SD SHT SP SPD SPEC TDH TPD TSP TYP V VD VTR W WB W/ WC WCO WG WH WHA AIR CONDITIONING AIR CONDITIONING UNIT ACCESS DOOR ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BACKDRAFT DAMPER BELOW FINISHED FLOOR BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CLEAN OUT CONDENSATE CONTINUATION COORDINATE CLEAN OUT TO GRADE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING, EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXISTING EXHAUST EXPANSION FAHRENHEIT FLOOR CLEANOUT FIRE DAMPER, FLOOR DRAIN FIRE DEPARTMENT CONNECTION FULL LOAD AMPS FEET PER MINUTE FOOT, FEET NATURAL GAS GAUGE GALLONS GALVANIZED GALLONS PER MINUTE GYPSUM WALL BOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HOT WATER RETURN HOT WATER SUPPLY INDIRECT DRAIN, INSIDE DIAMETER INVERT ELEVATION INCH KILOWATT (1000 WATTS) LEAVING AIR TEMPERATURE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MANUFACTURER MINIMUM MOUNTING NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER OVERFLOW ROOF DRAIN OUTSIDE STEM AND YOLK PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR RAIN LEADER, REFRIGERANT LIQUID ROOF DRAIN REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE REDUCED PRESSURE BACKFLOW PREVENTER REFRIGERANT STEAM SUPPLY AIR STORM DRAIN SHEET STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER CLOSET WALL CLEAN OUT WATER GAUGE WALL HYDRANT WATER HAMMER ARRESTER NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED 6/4/2018 6:07:40 PM SYMBOL ABBR OR XX. 0 XxY XXX + DN 11" I UP I + UP f S-54- + DN VD RA/EA RG -�-' SA SA -"'I- 01-1- RA/EA I` 1 SD >CI EQUIP ID# EA DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DUCT OFFSET DOWN IN FLOW DIRECTION DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION MO.1 ABBREVS., LEGEND, DRAWING INDEX, GENERAL NOTES, HP LOAD CALCULATION, SCHEDULES AND MECHANICAL DETAILS MD2.1 ELEVATOR LANDING AND MACHINE ROOM MECHANICAL DEMOLITION FLOOR PLANS MD2.2 ELEVATOR LANDING AND ROOF MECHANICAL DEMOLITION PLANS M2.1 ELEVATOR LANDING AND MACHINE ROOM MECHANICAL FLOOR PLANS EVD2.1 ELEVATOR LANDING AND MACHINE ROOM ELEVATOR DEMOLITION FLOOR PLANS EVD2.2 ELEVATOR LANDING AND ROOF ELEVATOR DEMOLITION PLANS EV2.1 ELEVATOR LANDING AND MACHINE ROOM ELEVATOR FLOOR PLANS EV2.2 ELEVATOR LANDING AND ROOF ELEVATOR PLANS EV2.3 ELEVATOR DIAGRAMS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE ENGINEER. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. INSULATION SHALL MEET WASHINGTON STATE ENERGY CODE (WSEC). 5. PENETRATIONS THROUGHOUT 2 -HOUR FIRE RATED WALLS, PARTITIONS, CEILINGS A ROOF ASSEMBLIES SHALL RECEIVE 2 -HOUR FIRE STOP RATED UL APPROVED SEAL FROM INSIDE AND WEATHER RESISTANT SEALANT FROM OUTSIDE. AIR DISCHARGE FAN RS & RL TO INDOOR UNIT, HP -1 SERVICE PANEL RS & RL, MAKE FLEXIBLE BY SECURING WITH PIPE CLAMP OVER INSULATION TRANSPORTING HANDLE PROVIDE PVC VANDAL 4 RESISTANT COVER FOR ABOVE GROUND RS & RL NEOPRENE VIBRATION ISOLATORS 6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 7. PROVIDE ALL REQUIRED EQUIPMENT GUARDS AND STRUCTURAL SUPPORT AS RECOMMENDED BY EQUIPMENT MANUFACTURERS TO SUPPORT EQUIPMENT AND TO ASSURE SYSTEM PERFORMANCE AND SAFE OPERATION. COORDINATE PRIOR TO INSTALLATION. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, -ACCESS VALVES AND DAMPER OPERATORS. ;, • 6vii NIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. BUILDING AND RE IS DESIGNED TO SUPPORT EQUIPMENT, BUT NOT DETAILED TO ACCOMMODATE EACH AVAILABLE EQUIPMENT CONFIGURATION OR MANUFACTURER. (.1 � COCONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WIN TURNING VANES SWITCH OR THERMOSTAT EQUIPMENT LOCATION 0 D 0 RS RL C RS RL C PIPE/DUCT ELBOW DOWN PIPE/DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT REFRIGERANT SUCTION PIPING REFRIGERANT LIQUID PIPING CONDENSATE PIPING ROOM CALL OUT 9. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. SPR 2 8 26: HP LOAD CALCULATION ELEVATOR MOTOR = 25HP HOURLY DUTY CYCLE = 12% WATTS PER MOTOR HP = 746 WATTS SENSIBLE/TOTAL COOLING RATIO = 69% SENSIBLE HEAT GAIN = 25HP x 746W/HP x 12% x 3.413(BTU/H)/W = 7.638 BTU/H SENSIBLE GROSS TOTAL COOLING LOAD = 7,638(BTU/H)/69% = 11.070 BTU/H TOTAL HP -1 TOTAL COOLING PROVIDED = 18.000 BTU/H TOTAL HP -1 Illllu 11 11 —1 ��11�11�1 II 11111 11 _I�1�m�1111r 11IIIL1 I�1IJLI�1 11at-11, j I II HEAT PUMP OUTDOOR UNIT, HP -1 PVC SLEEPERS GRADE HP -1 OUTDOOR UNIT INSTALLATION DETAIL SCALE: NTS REFRIGERANT LIQUID AND SUCTION LINES TO OUTDOOR UNIT SACK HP -1 INDOOR UNIT, WALL MOUNTED FRONT PUMP CONDENSATE DRAIN LINE, TERMINATE 6" ABOVE EXTERIOR GRADE I 2 HP -1 INDOOR UNIT INSTALLATION DETAIL SCALE: NTS • cc11cc11ttctcc11ccc4,,,,„l 111111111111 FIRE RATED SEALANT (MIN. 3 HR RATED) ESCUTCHEON, 24 GA GI WHERE EXPOSED WITHIN FINISHED ENVIRONMENT PIPE PIPE THROUGH WALL DETAIL ® SCALE: NTS HEAT PUMP UNIT SCHEDULE MARK CFM EXT. STATIC PRES. COOLING NOMINAL BTUH HEATING NOMINAL BTUH SEER WEIGHT, LBS. ELECTRICAL DESCRIPTION MCA MOCP VOLT PHASE HP -1 700 0.0" 18,000 INDOOR 19,000 INDOOR 15.3 29 1 20 208/ 230 1 MITSUBISHI PKA-A18HA4 OR ACCEPTED EQUAL, WALL -MOUNTED INDOOR UNIT, WITH REFRIGERANT LINE KIT, CONDENSATE PUMP AND WALL - MOUNTED THERMOSTAT. OUTDOOR OUTDOOR 15.3 91 13 208/ 230 1 PUZ-A18NHA4 OR ACCEPTED EQUAL. PROVIDE 3-1/4" X 3-1/4" PVC SLEEPERS, MITSUBISHI DSD -400N OR ACCEPTED EQUAL. NOTES: 1. ECONOMIZER NOT REQUIRED PER WSEC PART C403.3, EXCEPTION 3. AP23 EOfatVEDFaT CODE COMPLIANCE APPROVED OCT 2 4 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 31 2018 PERMIT CENTER SEPARATE PERMIT AND APPROVAL REQUIRED SHKSARCHITECTS 1050 N.38th St. Seattle, WA 98103 PH: 206.675.9151 www.shksarchitects.com THE GREENBUSCH GROUP, INC. King County Housing Authority KCHA RIVERTON TERRACE II ELEVATORS PERMIT SET 14410 41ST AVE S TUKWILA, WA 98169 Drawn by: Checked: Date: Scale: Revisions: No. Date DR RF 8/272018 1/4" = 11-0" Remarks ABBREVS., LEGEND, DRAWING INDEX, GENERAL NOTES, HP LOAD CALCULATION, SCHEDULES AND MECHANICAL DETAILS M0.1 6/4/2018 6:07:40 PM SHEET NOTES: 1. THE DEMOLITION DRAWINGS ARE DIAGRAMMATIC IN NATURE. CONTRACTOR IS RESPONSIBLE FOR COMPLETE REMOVAL OF INDICATED SYSTEMS & ASSOCIATED APPURTENANCES UNIT FLAG NOTES: REMOVE EXISTING LOUVER, INFILL, PATCH, AND PAINT WALL TO MATCH SURROUNDING WALL. CUT AND CAP EXTRANEOUS PIPE THAT PROTRUDES INTO ELEVATOR PIT AND PATCH WALL. REMOVE UNRELATED CONDUIT AND JUNCTION BOX IN THE PIT AND PATCH WALL. REMOVE EXISTING SPRINKLER HEAD AND PIPING, CAP PIPING AS SHOWN AT THE MACHINE ROOM AND REROUTE SPRINKLER LINE TO PIT, AS SHOWN ON M2.1. UNIT LOBBY (E) MAILBOXES (E) LOUVER FIRST FLOOR PLAN 1/4" = 1'-0" (E) STAIRS ti RR MAINTENANCE ELEC LAUNDRY APR 2 8-201g, • REMOVE EXHAUST FAN, CAP DUCT, PATCH AND INFILL. MACHINE (E) EXTRANEOUS PIPE (E) SPRINKLER LINE LOBBY (E) JUNCTION BOX KITCHEN BASEMENT 1/4" = 1'-0" COMMUNITY ROOM (E) LOUVER RR OFFICE 0 4 (E) STAIRS CODE COMPLIANCE APPROVED OCT 242018 City of Tukwila BUILDING DIVISION '( OF TUKWILA — AUG 31 2018 SHKSARCHITECTS 1050 N.38th St. Seattle, WA 98103 PH: 206.675.9151 www.shksarchitects.com PERMIT CENTER SEPARATE PERMIT AND APPROVAL REQUIRED 8 16 THE GREENBUSCH GROUP, INC. King County Housing Authority KCHA RIVERTON TERRACE II ELEVATORS PERMIT SET 14410 41ST AVE S TUKWILA, WA 98169 Drawn by: Checked: Date: Scale: Revisions: No. Date DR RF 8/272018 1/4" = 1'-0" Remarks ELEVATO R LANDING AND MACHINE ROOM MECHANICAL DEMOLITION FLOOR PLANS CD MD2.1 SHEET NOTES: FLAG NOTES: 1. THE DEMOLITION DRAWINGS ARE DIAGRAMMATIC IN NATURE. CONTRACTOR IS RESPONSIBLE FOR COMPLETE REMOVAL OF INDICATED SYSTEMS & ASSOCIATED APPURTENANCES 6/4/2018 6:07:40 PM REMOVE EXISTING LOUVER, INFILL, PATCH, AND PAINT WALL TO MATCH SURROUNDING WALL. REtv1OVE EXISTING VENT, CAP ROOF CURB. O E) LOUVER SHKSARCHITECTS An 2 8 28'0 UNIT LOBBY NO MECHANICAL DEMOLITION WORK IN THIS LEVEL UNIT SECOND FLOOR PLAN 1/4" = 1'-0" (E) STAIRS REVIEVVED FOP. CODE COMPLIANCE APPROVED OCT 2 4 2013 City of Tukwila BUILDING DIVISION 1050 N.38th St. Seattle, WA 98103 PH: 206.675.9151 www.shksarchitects.com _.?:.IV£::L3 CITY OF TUKWILA AUG 31 2018 RERMF 7 CENTER SEPARATE PERMIT AND APPROVAL REQUIRED THE GREENBUSCH GROUP, INC. King County Housing Authority KCHA RIVERTON TERRACE II ELEVATORS PERMIT SET 14410 41ST AVE S TUKWILA, WA 98169 Drawn by: DR Checked: RF Date: 8/272018 Scale: 1/4" = 1'-0" Revisions: No. Date Remarks ELEVATOR LANDING AND ROOF MECHANICAL DEMOLITION PLANS W MD2.2 6/4/2018 6:07:40 PM DRAWING NOTES: 1. PROVIDE CUTTING AND PATCHING AS SPECIFIED AND AS REQUIRED TO INSTALL NEW PIPING AND EQUIPMENT. UNIT FLAG NOTES: (E) MAILBOXES LOBBY NO MECHANICAL WORK THIS LEVEL CUT AND PATCH WALL AS REQUIRED TO INSTALL HP -1 REFRIGERANT PIPING. COORDINATE LOCATION OF HP -1 INDOOR UNIT WITH THE ELEVATOR CONTRACTOR AND KCHA CONSTRUCTION MANAGER PRIOR TO WALL CUTTING. INSTALL HP -1 INDOOR UNIT IN ELEVATOR MACHINE ROOM. ROUTE RL/RS ABOVE THE CEILING TILES TO THE HP -1 OUTDOOR UNIT MOUNTED OUTDOORS. PROVIDE PVC CONTAINMENT FOR ALL EXPOSED REFRIGERANT AND CONDENSATE PIPING. PAINT TO MATCH EXISTING WALL COLOR. PUMP CONDENSATE TO EXTERIOR. TERMINATE 6" ABOVE GRADE. COORDINATE FINAL HP -1 OUTDOOR UNIT LOCATION WITH KCHA CONSTRUCTION MANAGER. UNIT FIRST FLOOR PLAN 1/4" =1'-0" (E) STAIRS • LOCATE HP -1 OUTDOOR UNIT ON SLEEPERS. REFER TO EQUIPMENT SCHEDULE AND ARCHITECTURAL DOCUMENTS.. MOUNT SIDE—WALL SPRINKLER NOT MORE THAN 2' ABOVE PIT FLOOR. COORDINATE SPRINKLER LOCATION AND PIPE ROUTING WITH ELEVATOR CONTRACTOR. An 2 t3 a3 RR LU CD CC 1 - MAINTENANCE ELEC SEE SHKSARCHITECTS 2 APR 23 2O LAUNDRY KITCHEN ROUTE REFRIGERANT— INSIDE WALL, EXIT THE WALL WITHIN .44 12" OF THE OUTDOOR UNIT COMMUNITY ROOM 6 SEE 8 a x P.O.0 LOBBY MACHINE FIRS, R�, C RR OFFICE I i E i y t t E'D FOR e CODE COMPLIANCE • ,.jPROV . D OCT 2 4 2313 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 31 2018 PERMJlU CENTER SEPARATE PERMIT AND APPROVAL !RED 1050 N.38th St. Seattle, WA 98103 PH: 206.675.9151 www.shksarchitects.com BASEMENT 1/4" = 1'-0" 4 16 THE GREENBUSCH GROUP, INC. King County Housing Authority KCHA RIVERTON TERRACE II ELEVATORS PERMIT SET 14410 41ST AVE S TUKWILA, WA 98169 Drawn by: Checked: Date: Scale: Revisions: No. Date DR RF 8/272018 1/4" = 1'-0" Remarks ELEVATOR LANDING AND MACHINE ROOM MECHANICAL FLOOR PLANS M2.1 6/4/2018 6:07:40 PM GENERAL DEMOLITION NOTES: 1. THE DEMOLITION SHOWN DOES NOT ATTEMPT TO COVER ALL ITEMS WHICH MUST BE REMOVED OR REPLACED AS PART OF THE ELEVATOR MODERNIZATION. CONTRACTOR IS NOT RELIEVED FROM PROVIDING ALL DEMOLITION SERVICES REQUIRED TO COMPLETE THE SCOPE SPECIFIED IN THE CONTRACT DOCUMENTS. UNIT FLAG NOTES: REMOVE EXISTING SHUTOFF VALVE, RUPTURE VALVE AND ASSOCIATED LENGTH OF PIPE TO ALLOW INSTALLATION OF NEW SHUT OFF VALVE AND RUPTURE VALVE. REMOVE EXISTING POWER UNIT & ASSOCIATED CONTROLLER. REMOVE EXISTING HYDRAULIC LINES ALONG WITH THE EXISTING SHUTOFF VALVE AND MUFFLER. REMOVE EXISTING INGROUND JACK ASSEMBLY COMPLETE. DEMOLISH SURROUNDING SLAB AS REQUIRED FOR REMOVAL. REMOVE EXISTING HALL LANTERNS AND FIXTURES. LOBBY (E) MAILBOXES VESTIBULE UNIT FIRST FLOOR PLAN 1/4" = 1'-0" (E) STAIRS ti RR LU CC0 MAINTENANCE ELEC APR 2 3 leg LAUNDRY CONTROLLER (E) JACK LOBBY KITCHEN COMMUNITY ROOM SHKSARCHITECTS 1050 N.38th St, Seattle, WA 98103 PH: 206.675.9151 www.shksarchitects.com RR OFFICE (E) STAIRS • CODE COMPLIANCE n nR I INCE APPROVi 7 OCT 2 4 2U13 City of Tukwila BUILDING DIVISION REt; E1\"E CITY OF TUKWILA AUG 31 2013 PERMIT CENTER THE GREENBUSCH GROUP, INC. King County Housing Authority KCHA RIVERTON TERRACE II ELEVATORS PERMIT SET 14410 41ST AVE S TUKWILA, WA 98169 Drawn by: Checked: Date: Scale: Revisions: No. Date DR RF 8/272018 ..... _ _..... 1/4" =1'-0" Remarks ELEVATOR LANDING AND MACHINE ROOM ELEVATOR DEMOLITION FLOOR PLANS EVD2.1 SHEET NOTES: 1. THE DEMOLITION DRAWINGS ARE DIAGRAMMATIC IN NATURE. CONTRACTOR IS RESPONSIBLE FOR COMPLETE REMOVAL OF INDICATED SYSTEMS & ASSOCIATED APPURTENANCES 6/4/2018 6:07:40 PM FLAG NOTES: REMOVE EXISTING HALL LANTERNS AND FIXTURES. APa . 3.26113! NO ELEVATOR DEMOLITION WORK IN THIS LEVEL )ROOF 1/4" = 1'-0" AP? 2 3; OZ. SHKSARCHITECTS UNIT UNIT LOBBY SECOND FLOOR PLAN 1/4" = 1'-0" (E) STAIRS CODE. CCv.OJANCE • r i4a0 E OCT 242013 City of Tukwila BUILDING DIVISION 1050 N.38th St. Seattle, WA 98103 PH: 206.675.9151 www.shksarchitects.com E ECE1VE0 C ITS, OF TUKWiLA AUG 31 2018 PEFIMIT CENTER 8 16 THE GREENBUSCH GROUP, INC. King County Housing Authority KCHA RIVERTON TERRACE II ELEVATORS PERMIT SET 14410 41ST AVE S TUKWILA, WA 98169 Drawn by: Checked: Date: Scale: Revisions: No. Date DR RF 8/272018 1/4" = Remarks ELEVATOR LANDING AND ROOF ELEVATOR DEMOLITION PLANS EVD2.2 6/4/2018 6:07:40 PM SHEET NOTES: 1. PROVIDE CUTTING AND PATCHING AS SPECIFIED AND AS REQUIRED TO INSTALL NEW PIPING AND EQUIPMENT. UNIT FIRST FLOOR PLAN VESTIBULE (E) MAILBOXES LOBBY 4>>> UNIT FLAG NOTES: PROVIDE NEW SURFACE MOUNTED HALL CALL BUTTONS. PROVIDE NEW SURFACE MOUNTED HALL LANTERNS. PROVIDE NEW SUBMERSIBLE POWER UNIT AND SOLID STATE MICROPROCESSOR BASED CONTROLS. HALL BUTTON FIXTURES AT EACH FLOOR SHALL BE PROVIDED WITH INTEGRAL POSITION INDICATORS. NEW SHUTOFF VALVE MOUNTED IN VERTICAL. PROVIDE NEW SHUTOFF VALVE AND RUPTURE VALVE. CUT AND PATCH WALL AS REQUIRED TO INSTALL NEW HYDRAULIC LINE. PROVIDE NEW DOUBLE BOTTOM JACK ASSEMBLY. REPLACE SURROUNDING SLAB AS NECESSARY. (E) STAIRS An (c6 1/4" = 1'-0" RR w CD CC 0 cip MAINTENANCE ELEC (N) HP -1 (BY MECHANICAL) LAUNDRY LIGHT SWITCH, DISCONNECT (BY ELECTRICAL) LOCATE WITHIN 24 INCHES OF THE CONTROL ROOM DOOR STRIKE SIDE (NIEC) PROVIDE PIT ACCESS LADDER AND LIGHT SWITCH (NIEC). LOBBY KITCHEN BASEMENT 1/4" = COMMUNITY ROOM ONTROLLE C RR OFFICE 0 SHKSARCHITECTS 1050 N.38th St. Seattle, WA 98103 PH: 206.675.9151 www.shksarchitects.com REV iEVj -�L.� FOR i a E�w r CODE CCI.'ds:. LlANCE APPROVLD OCT 2 4 2013 City of Tukwila BUILDING DIVISION ENE o UP/ OF. TUKWILA 16 AUG 31 2018 PERMIT CENTER THE GREENBUSCH GROUP, INC. King County Housing Authority KCHA RIVERTON TERRACE II ELEVATORS PERMIT SET 14410 41ST AVE S TUKWILA, WA 98169 Drawn by: Checked: Date: Scale: Revisions: No. Date DR RF 8/272018 1/4" = 1'-O" Remarks ELEVATOR LANDING AND MACHINE ROOM ELEVATOR FLOOR PLANS EV2.1 SHEET NOTES: 1. PROVIDE CUTTING AND PATCHING AS SPECIFIED AND AS REQUIRED TO INSTALL NEW PIPING AND EQUIPMENT. 6/4/2018 6:07:40 PM FLAG NOTES: PROVIDE NEW SURFACE MOUNTED HALL CALL BUTTONS. PROVIDE NEW SURFACE MOUNTED HALL LANTERNS. HALL BUTTON FIXTURES AT EACH FLOOR SHALL BE PROVIDED WITH INTEGRAL POSITION INDICATORS. L_J NO ELEVATOR WORK IN THIS LEVEL ROOF. 1/4" = APR 2 3 2010 UNIT LOBBY >>> UNIT SECOND FLOOR PLAN 1/4" = 1'-0" 4 (E) STAIRS 8 SHKSARCHITECTS 1050 N.38th St. Seattle, WA 98103 PH: 206.675.9151 www.shksarchitects.com REVL COD CC ,t:.;Li/ CE • OCT 242313 City of Tukwila BUILDING DIVISION• fr.CE1v c {..f CITY OF TUKWILA AUG 31 2018 PERMIT CENTER 16 THE GREENBUSCH GROUP, INC. King County Housing Authority KCHA RIVERTON TERRACE II ELEVATORS PERMIT SET 14410 41ST AVE S TUKWILA, WA 98169 Drawn by: Checked: Date: Scale: Revisions: No. Date DR RF 8/272018 1/4" = 1'-0 Remarks ELEVATOR LANDING AND ROOF ELEVATOR PLANS CD EV2.2 SHEET NOTES: 1. PROVIDE CUTTING AND PATCHING AS SPECIFIED AND AS REQUIRED TO INSTALL NEW PIPING AND EQUIPMENT. FLAG NOTES: 6/4/2018 6:07:40 PM PROVIDE NEW POSITION INDICATORS INTEGRATED WITHIN HALL FIXTURES AT EACH LANDING EXISTING JACK TO BE REMOVED AND REPLACED WITH NEW DOUBLE BOTTOM JACK. PROVIDE SHUT—OFF VALVES AND SEISMIC SAFETY VALVE. SPRING BUFFERS AND CHANNEL, PROVIDE NEW GUIDE RAILS EXISTING TO REMAIN. PROVIDE RAIL BACKING OR FISH PLATES AS REQUIRED TO MEET THE ELEVATOR SAFETY CODE. FIELD VERIFY AND PROVIDE QUANTITY REQUIRED. ELEVATOR CAR FRAME AND PLATFORM EXISTING TO REMAIN. FINISHES AS SPECIFIED . PROVIDE NEW HANDRAILS. PROVIDE NEW HALL LANTERNS PROVIDE CAR EXHAUST FAN. PROVIDE CAR OPERATING PANEL WITH TELEPHONE, INTERCOM EMERGENCY LIGHT AND LED POSITION, DIRECTION INDICATORS, AND KEYSWITCH OVERRIDE. PROVIDE CAR LED LIGHTING. PROVIDE CAR TOP OPERATING STATION. PROVIDE NEW TRAVELING CABLES. PROVIDE TERMINAL LIMIT SWITCHES. PROVIDE ADA JAMB PLATES. PROVIDE HALL BUTTONS TO MEET ACCESSIBILITY REQUIREMENTS. PROVIDE NEW TOE GUARD. FASCIA PLATES EXISTING TO REMAIN. LANDING SILLS ARE EXISTING TO REMAIN. PROVIDE NEW CLOSED LOOP DOOR OPERATOR. PROVIDE DUST COVER PROVIDE DOOR EDGE PROTECTION DEVICE. PROVIDE FIRE SIGNAGE AT EACH LANDING PROHIBITING USE OF ELEVATOR,DURING FIRE. SIGNAGE MAY BE INCORPORTATED INTO HALL STATIONS. PROVIDE NEW ROLLER GUIDES. PROVIDE CAR TOP HATCH WITH ALARM. PROVIDE CAR TOP HAND RAILS AS REQUIRED BY WAC 296-96-23117 (VERIFY) PATCH ALL EXISTING AND CREATED HOLES IN THE HOISTWAY. PROVIDE NEW INTERCOM AT FIRST FLOOR LOBBY. PROVIDE NEW FIRE DEPARTMENT KEY BOX AT FIRST FLOOR LOBBY. PROVIDE NEW SLAB AS REQUIRED DURING JACK REPLACEMENT. HOISTWAYS ENTRANCES REPAINTED (BY OTHERS). PROVIDE NEW CODE COMPLIANT PIT LADDER. PROVIDE HOISTWAY ACCESS KEYSWITCHES AT TERMINAL LANDINGS. 15 ROOF 21 22 TYP 19 LEVEL 3 18 LEVEL 2 LEVEL 1 2 a.w 0 20 33 DIAGRAMMATIC HOISTWAY SECTION TYP 1_ tiro •��:' 14 TYP TO ELEVATOR MACHINE ROOM APR 23 2134 34 16 TYPICAL ELEVATOR LOBBY SCALE: NTS (TYPICAL) 13 CAR FRONT ELEVATION CAR FLOOR PLAN CAR SIDE ELEVATION TYP TYP f TYP NOTE: REFER ARCHITECTURAL FOR ADDITIONAL LOCATION INFORMATION SHKSARCHITECTS CAR REAR ELEVATION o 0 *►IIIIM_ 0 < 0 I CAR RCP CAR SIDE ELEVATION ?..1A/ CODS. Ca7JYA.N€AC° C . APPk3VLD OCT 242013 City of Tukwila BUILDING DIVISION RECEIVF-D. CITY OF TUKWILA AUG 31 2018 PERMIT CENTER 1050 N.38th St. Seattle, WA 98103 PH: 206.675.9151 www.shksarchitects.com THE GREENBUSCH GROUP, INC. King County Housing Authority KCHA RIVERTON TERRACE II ELEVATORS PERMIT SET 14410 41ST AVE S TUKWILA, WA 98169 Drawn by: Checked: Date: Scale: Revisions: No. Date DR RF 8/272018 1/4" = 11-0" ELEVATOR DIAGRAMS Remarks EV2.3 120VOLT TRIPS SHUNT TRIP WHEN IN ALARM. DETECTORS DO NOT CONNECT TO FA SYSTEM LIGHTING FIXTURE SCHEDULE TYPE LAMP MANUFACTURER CATALOG DESCRIPTION EM LED 32W 4000K EP LED 32W 4000K L3 LED 9W 3000K DAYBRITE DW-P-E-35L-4-UNV DAYBRITE DW-P-E-35L-4-UNV PRESCOLITE CDL4-7L3OKA-WH ELEVATOR MACHINE ROOM LIGHT. SURFACE CEILING MOUNTED ENCLOSED INDUSTRIAL. ELEVATOR PIT LIGHT. SURFACE WALL MOUNTED ENCLOSED INDUSTRIAL VAPORTIGHT. 4" RECESSED ELEVATOR CAB LIGHT. ALL COLORS, FINISHES, ETC. ARE BY ARCHITECT FROM MANUFACTURER'S STANDARD OPTIONS. 120 VOLT DEDICATED CIRCUIT PROVIDE LABEL ON ELEVATOR DISCONNECT "SHUNT TRIP POWER CIRCUIT XXX" INDICATOR LIGHT ON WHEN POWER IS AVAILABLE FAILURE OF LAMP DOES NOT REMOVE POWER FROM HEAT DETECTOR DEDICATED LIGHT CCT 7 MACHINE ROOM ikPiZ S VIT 24V DC PANEL ELEV LOCATION MOUNTING AIC FED FROM CCT NO. ELEV MACH ROOM SURFACE 10,000 EXISTING PANEL CCT DESCRIPTION BRKR VOLTS 240 /120 AMPS 50 MAIN BREAKER GROUND BUS LOAD 1 CCT 1 PHASE 3 WIRE CCT DESCRIPTION KVA I NO. BRKR LOAD KVA I 20/ 3 20/ 5 20/ 7 20/ 9 20/ 11 20/ CONNECTED LOAD KVA CAB LTS & EF LTS & RECEPTS PIT LTS & REC DAMPER RECEPTS RECEPTS 0.15 0.24 0.24 0.20 0.18 0.18 2 4 68 I0 12 DEMAND FACTOR 20/1 SPACE 20/1 SPACE 20/2 HP -I OUTDOOR 20/1 SHUNT -TRIP 20/I SPACE DEMAND LOAD 0.00 0.00 3.74 0.00 0.10 0.00 KVA AMPS LIGHTS RECEPTACLES HEATING LARGEST MOTOR OTHER MOTORS MISCELLANEOUS KITCH. APPLIANCES • 24V DC CAB LIGHTING DISCONNECT . -SIGNAL FROM SHAFT OR MACHINE ROOM INITIATES RECALL TO "RECALL" OR "ALTERNATE FLOOR". ALL CONTROLS BY ELEVATOR INSTALLER. SHAFT UPPER LEVEL ELEVATOR LOBBY MAIN LEVEL ELEVATOR LOBBY 0.18 0.72 0.00 3.74 0.30 0.10 0.00 CIRCUIT BREAKER FOR ELEVATOR LIGHTING CIRCUIT ELEVATOR DETAIL NTS `- ELEVATOR CONTROLLER ALL RECEPTACLES IN ROOM GFI TYPE ELEVATOR ELEVATOR LIGHTS SHUNT TRIP FUSED DISCONNECT INCOMING LINE NOTES: PIT 1. DETAIL SHOWS LOWER LEVEL AND TOP LEVEL. INTERIM LEVELS NOT SHOWN. REFER TO FLOOR PLANS FOR WORK AT INTERIM LEVELS. PIT RECEPTACLE AND LIGHT ON DEDICATED CIRCUIT. GFI RECEPTACLE 5.04 25% 00% 00% 25% 00% 00% 00% 0.23 0.72 0,00 4.68 0.30 0.10 0.00 0.95 3.00 0.00 19.48 1.25 0.42 0.00 6.02 25.09 MAIN SWITCH 1500, 240/120V,10,3W r I � TO UTILITY -r------1----I 0 LEGEND CONDUIT CONCEALED IN CEILING OR WALLS 3/4" CONDUIT. TICK MARKS INDICATE NUMBER OF #12 WIRES. NO TICK MARKS EQUALS 2#12. GROUND WIRE NOT SHOWN. PROVIDE GROUND WIRE IN ALL 120V AND ABOVE CIRCUITS. HOME RUN TO DESTINATION INDICATED. SURFACE MOUNTED LIGHT FIXTURE 0 RECESSED LIGHT FIXTURE J. XOX 01 0 FA GFI WALL MOUNTED LIGHT FIXTURE WALL SWITCH WALL SWITCH WITH INTEGRAL OCCUPANCY SENSOR XXXX = LIGHTING FIXTURE TYPE DESIGNATOR, SEE LIGHT FIXTURE SCHEDULE DUPLEX RECEPTACLE DUPLEX RECEPTACLE GFI TYPE WEATHERPROOF DUPLEX RECEPTACLE (GFI TYPE) EQUIPMENT CONNECTION MOTOR CONNECTION DISCONNECT SWITCH FUSED DISCONNECT SWITCH JUNCTION BOX DATA OUTLET, 2-RJ45 JACKS, ELEVATOR COMMUNICATION LINES SMOKE DETECTOR HEAT DETECTOR FIRE ALARM RELAY FIRE ALARM STROBE GROUND FAULT CIRCUIT INTERRUPTER WP WEATHERPROOF rzIM FIRE ALARM SYSTEM CIRCUITRY AS REQUIRED BY MANUFACTURER. ROUTE IN METALLIC RACEWAY WHERE IN WALLS, ABOVE NON-ACCCESSIBLE CEILINGS OR EXPOSED. COMMUNICATION RACEWAY, 3/4"EMT MINIMUM. PROVIDE (2)CAT6 CABLES TO DESTINATION INDICATED 480V PANEL 208V PANEL EXIST DEVICE AS INDICATED REMOVE EXISTING FEEDER AND INSTALL NEW AS NOTED. 2" 4#3/0, 1#6GND / , 1.25"-4#3, 1#8GND ELEVATOR MAIN DISCONNECT SWITCH 200/3 yy I --1 100/2 100/2 400/2 100/3 -.vim TO 120V SOURCE SHUNT (PNL ELV) TRIP ELEVATOR CONTROLLER 4 L PARTIAL ONE -LINE G NTS LEVATOR REMOVE PARALLEL FEEDERS AND SUB -BREAKERS PROVIDE SWITCH -GEAR BLANKS PNL L2 100A, 240/120V -10-3W I 100/2-1 n 150/2 EX PNL L1 400A, 240/120V -10-3W 400/2 I ' I I I I L J 1"-3#6, 1#8 GND PNL ELV SHKSARCHITECTS APR 2 3 20i . CODE CC PI 1/ CE Ari ' '1(aVLD OCT 2 4 2013 City of Tukwila BUILDING DIVISION C£T'( OF TUKWILA AUG 31 2018 PERMIT CENTER SEPARATE PERMIT AND APPROVAL REQUIRE'; 1050 N.38th St. Seattle, WA 98103 PH: 206.675.9151 www.shksarchitects.com FITZMAURICE - & ASSOCIATES 1200 Westlake Ave. N., Suite 509 - p 206.285.7228 Elecincal Engineers Seattle, WA 98109 (206.285-7294 King County Housing Authority KCHA RIVERTON TERRACE II ELEVATORS PERMIT SET 14410 41ST AVE S - TUKWILA, WA 98169 Drawn by: Checked: Date: Scale: - Revisions: _ No. Date PM RJ 8/27/2018 As indicated Remarks - LEGENDS, SCHEDULES & _ DETAILS - - ELECTRICAL E0.1 UNIT LOBBY DEMO EX EXHAUST FAN AND RECEPTACLE DEMO LIGHTS IN CAB UNIT VESTIBULE FIRST FLOOR PLAN - ELECTRICAL A CMACHINE ROOM CEILING - ELECTRICAL Q' 1/4" = 1'-0" 1/4" =1'-0" DEMOLITION NOTES 1. EXISTING PLANS DO NOT INDICATE COMPLETE EXISTING WIRING CONDITIONS. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO START OF WORK. 2. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY IN FIELD THE EXISTING CONDITIONS, LOCATIONS AND SIZES OF EQUIPMENT AND ASSOCIATED APPARATUS BEING DEMOLISHED PRIOR TO COMMENCEMENT OF WORK 3. BEFORE ANY WIRING IS CUT, CONTRACTOR SHALL VERIFY USAGE OF WIIUNG TO BE CUT TO ASSURE THAT SERVICES REQUIRED ARE NOT DISCONTINUED TO OTHER PARTS OF THE FACILITY. PROVIDE ADDITIONAL WIIUNG, RACEWAYS, DEVICES AND OTHER ACCESSORIES TO ENSURE CONTINUITY OF SERVICE TO OTHER PARTS OF INSTALLATION TO REMAIN IN SERVICE. 4. PROTECT EXISTING RACEWAYS, WIRING AND CABLES TO REMAIN IN SERVICE AND WILL BE RE -USED. PROVIDE REQUIRED SUPPORT AS NEEDED. 5. REMOVE ALL EXISTING CONDUITS, CONDUCTORS, BOXES AND ASSOCIATED EQUIPMENT NO LONGER REQUIRED AS A RESULT OF THIS CONTRACT AND DISPOSE LEGALLY. NO ABANDONED IN PLACE EXISTING EQUIPMENT AND OTHER MATERIALS THAT ARE NO LONGER IN USE AS A RESULT OF THIS CONTRACT. 6. REMOVE ALL EXISTING ELECTRICAL INSTALLATIONS AND EQUIPMENT INDICATED TO BE REMOVED OR NO LONGER REQUIRED. PROVIDE COVER PLATE FOR BLANK OUTLETS AND JUNCTION BOXES. PLUG ALL HOLES ON BOXES AND CABINIETS TO REMAIN. 7. DELIVER ALL SALVAGEABLE MATERIAL AS DETERMINED BY OWNER. AT NO ADDITIONAL COST TO OWNER, PACK MATERIAL IN BOXES. COIL ALL CABLES AND TIE. CONTRACTOR TO LEGALLY DISPOSE ALL MATERIALS NO LONGER REQUIRED. FLAG NOTES: REMOVE PARALLEL FEEDERS AND (2) SUB -BREAKERS. PROVIDE (2) BLANKS COVER PLATES. MAIN SWITCHBOARD & METER CENTER FUSED 150A -3P FEE DS EXIST ELEVATOR EX PNL L2 EX PNL L1 RR EX COMM BOARD J --, — J EX FACP in ELEC APR 2 3 2010 DEMO ELEVATOR MAIN SWITCH DEMO EXIST ELEVATOR CONNECTION LAUNDRY DE 0 CAM LIGHT DISC DEMO CONTROLLER LOBBY DEMO FIXTURES IN PIT KITCHEN i (E) HARD LID ABOVE I BASEMENT PLAN - ELECTRICAL 1/4" = 1'-0" COMMUNITY ROOM / (E) 6" CLEAR ABOVE DROP CEILING RR OFFICE -- (E) STAIRS SHKSARCHITECTS 1 CODEs CC:. ,I . c. CE OCT 24C;.3 City of Tt faetfila BUILDING DIVISION IWE!:: wit OF TUKWILA AU6 31 2018 :sE :e�llI CENTER SEPARATE PERMIT AND APPROVAL REQUIRED 1050 N.38th St. Seattle, WA 98103 PH: 206.675.9151 www.shksarchitects.com & ASSOCIATES 1200 Westlake Ave. N., Suite 509 p 206.285.7228 FITZMAURICE Electrical Engineers Seattle, WA 98109 f206-285.7294 King County Housing Authority KCHA RIVERTON TERRACE II ELEVATORS PERMIT SET 14410 41ST AVE S TUKWILA, WA 98169 Drawn by: Checked: Date: Scale: - Revisions: No. Date PM RJ 8/27/2018 As indicated Remarks -- DEMOLITION FLOOR PLANS - ELECTRICAL ED2.0 UNIT LOBBY PROVIDE CAB EXHAUST FAN 1000W, 120V PROVIDE NEW LIGHTS IN CAB NEW LED FIXTURE TO FACP ELEV-3 MACHINE ROOM CEILING - ELECTRICAL TOP OF ELEV. CAB UNIT FIRST FLOOR PLAN - ELECTRICAL A sl 1/4" = 1'-0" AP7 .3 2010 MAIN SWITCHBOARD FUSED 150A -3P FEE METER CENTER S EXIST ELEVATOR EX PNL L2 EXPNL L1 RR EX COMM BOARD EX FACP ELEC SHUNT -TRIP DISCONNECT WITH INTEGRAL EPO BUTTON NO MORE THAN 2' FROM STRIKE SIDE DOOR FLAG NOTES: EXISTING SMOKE DETECTOR TO REMAIN. PROGRAM FACP FOR RECALL FUNCTION OF ELEVATOR. POWERED AT HP -1 OUTDOOR UNIT. FIRE ALARM RELAYS. CONNECT TO ELEVATOR CONTROLLER FOR ELEVATOR RECALL AND FIRE HAT FUNCTIONS HEAT DETECTOR, DUAL OUTPUT. PROVIDE CONNECTION TO FACP AND CONNECTION TO ELEVATOR SHUNT - TRIP. SYSTEM SENSOR OR APPROVED EQUAL. AP 2328 1/2" C, 4#12 & 1#12 GND TO HP -1 OUTDOOR UNIT HP -1 INDOOR MCA: 1 A, 240V�� LAUNDRY NEW ELEVATOR 25HP, 240V. MACHINE TO COMM BOARD NEW CAB LIGHT DISC PNL ELEV ELEVATOR PIT LOBBY KITCHEN �f (E) HARD LID ABOVE ELV-6,8 Ar HP -1 OUTDOOR MCA: 13A, 240V SLIDING WP BASEMENT PLAN - ELECTRICAL 1/4" =1'-0" COMMUNITY ROOM (E) 6" CLEAR ABOVE DROP CEILING 7 SLIDING RR OFFICE (E) STAIRS SHKSARCHITECTS ONTROLLER C: OCT 24 23 City of Tukwila BUILDING DIVISION RE:CEN E0 CITY OF TUKWILA, AUG 31 2018 PERMIT CENTER SEPARATE PERMIT AND APPROVAL REQUIRED 1050 N.38th St. Seattle, WA 98103 PH: 206.675.9151 www.shksarchitects.com — & ASSOCIATES 1200 Westlake Ave. 14., Suite 509 — p 206.285.7228 FITZMAURICE Electric al.Engineers3 Seattle, WA 98109 f206.285.7294 King County Housing Authority KCHA RIVERTON TERRACE II ELEVATORS PERMIT SET 14410 41ST AVE S — TUKWILA, WA 98169 Drawn by: Checked: Date: Scale: — Revisions: — No. Date PM RJ 8/27/2018 As indicated Remarks FLOOR PLANS - ELECTRICAL E2.0