Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D18-0301 - EDGEWOOD APARTMENTS - BEAMS AND COLUMNS REPLACEMENT
EDGEWOOD APARTMENTS 3730 S 148T" ST BLDG 1 D18-0301 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 0040000900 Permit Number: D18-0301 3730 S 148TH ST BLDG 1 Project Name: EDGEWOOD APARTMENTS Issue Date: 10/19/2018 Permit Expires On: 4/17/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: EDGEWOOD APARTMENTS LLC 9212 NE 20TH ST, CLYDE HILL, WA, 98004 MOHAMMAD AMINPOUR 3730 S 148TH ST - OFFICE , TUKWILA, WA, 98168 AFFIDAVIT - MOHAMMAD AMINPOUR Phone: (206) 353-7857 Phone: Expiration Date: DESCRIPTION OF WORK: REPAIR AND/OR REPLACE BEAMS AND COLUMNS TO SUPPORT WALKWAYS Project Valuation: $2,000.00 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $257.15 Occupancy per IBC: R-2 Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channelization/Striping: r1 Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: ,/ Land Altering: Volumes: Cut: 0 Fill: 0 Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No, Permit Center Authorized Signature: it r) Date: 10 � I vl I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: /),//121471 -- Rata A-4"t-ck) i'Vtlki Date: a8 --ici—a4ir This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0409 FRAMING CITY OF TUKCA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Per Project No. Date Application Accepted: Date Application Expires: 1 Ell Mai (For ogle use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: Tenant Name: PROPERTY OWNER Name: '1/1©ttoMmad 4$4.,1„ our Name: t,/i dkArt4 wt i h re-v'r City: T��e 14_ State: A Zip: 'Igor /ri Address: 3730 S". Piogit- s Qr -4 Email: ©l>hi H p0 v r a 4 in Ca .ct. i1 it City: --/-4,,, Ia State: w A...- Zip: Ct Vti 4j CONTACT PERSON — person receiving all project communication Name: '1/1©ttoMmad 4$4.,1„ our Address: 3730 s. i qg S‘.eie .� � City: T��e 14_ State: A Zip: 'Igor /ri Phone: ,)3 3 78,51ax: (L( _3) 5(3.2:_ei i 4 7 Email: ©l>hi H p0 v r a 4 in Ca .ct. i1 it GENERAL CONTRACTOR INFORMATION Company Name: Engineer Name: yv, g .3: R• le) S,E. Company Name: City: o,)4( State: A_ Zip: got f l Address: Architect Name: City: State: Zip: Phone: Fax: Phone: Fax: Contr Reg No.: Email: Exp Date: Tukwila Business License No.: H:'Applications\Forms-Applications On Line\2012 Applications'Permit Application Revised - 2-7-12.docx Revised: February 2012 bh King Co Assessor's Tax No.: 00 L/000.077!0 Suite Number: / Floor: New Tenant: ❑ Yes ❑..No ARCHITECT OF RECORD Company Name: SS'S' e ,a j,,, Q r;',t g Engineer Name: yv, g .3: R• le) S,E. Company Name: City: o,)4( State: A_ Zip: got f l Phone:&iS) a 14 1 Fax: (?:43).).4 ) O,- ?Neff) Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Company Name: SS'S' e ,a j,,, Q r;',t g Engineer Name: yv, g .3: R• le) S,E. Address: A (l413 %—it -A -e- ) City: o,)4( State: A_ Zip: got f l Phone:&iS) a 14 1 Fax: (?:43).).4 ) O,- ?Neff) Email: ..‘, f 4,6.-@ SSSf►^S1-1wr, LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATI(,; 206-431-3670 • Valuation of Project (contractor's bid price): $ , etro Existing Building Valuation: $ q/461) 8190 Describe the scope of work (please provide detailed information): pkge s�� �,�L L1( A' Will there be new rack storage? ❑ ....Yes [No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1st Floor ,� „2q t��% rel tr ea pesQ(0 A -s - 3`d Floor Na�- @ f �--- _ /.., ?r Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 2 of 4 PUBLIC WORKS PERMIT INFTION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila 0 ...Water District #125 ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ .. Sewer Use Certificate 0... Highline ❑...Valley View ❑...Renton ❑ ...Sewer Availability Provided 0...Renton 0... Seattle Septic System: ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ .. Civil Plans (Maximum Paper Size — 22" x 34") ❑ .. Technical Information Report (Storm Drainage) 0... Geotechnical Report ❑ .. Bond 0... Insurance 0... Easement(s) 0...Maintenance Agreement(s) Proposed Activities (mark boxes that apply): ❑ .. Right-of-way Use - Nonprofit for less than 72 hours ❑ .. Right-of-way Use - No Disturbance ❑ .. Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way 0 ❑ .. Total Cut cubic yards ❑ .. Total Fill cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities ❑ .. Frontage Improvements ❑ .. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation ❑ .. Traffic Impact Analysis ❑ .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) 0...Right-of-way Use - Profit for less than 72 hours 0...Right-of-way Use — Potential Disturbance 0... Work in Flood Zone 0...Storm Drainage 0...Abandon Septic Tank ❑...Curb Cut 0... Pavement Cut 0...Looped Fire Line Domestic Water ❑ .. Permanent Water Meter Size (I) ❑ .. Temporary Water Meter Size (1) ❑ .. Water Only Meter Size If ❑ .. Sewer Main Extension Public ❑ .. Water Main Extension Public 0... Grease Interceptor ❑... Channelization 0... Trench Excavation ❑... Utility Undergrounding WO # (2) " WO # (3) " WO # WO # (2) " WO # (3) " WO # WO # 0 .. Deduct Water Meter Size " Private 0 Private 0 FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) 0 .. Water 0 .. Sewer 0 .. Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip H:\Applications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 3 of 4 PERMIT APPLICATION NOTES —L Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: /�/,y J/4/494.--- Print Name: f4 e k1 h1t M � (Y' A l'4 e — r Mailing Address: 3730 S, j gam' S e -- H:Wpplications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Day Telephone: City Date: I — .Lo it (20 (I) s-3 78'� 7 (kik ‘IY1 State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT PermitTRAK 1 QUANTITY PAID $257.15 D18-0301 Address: 3730 S 148TH ST BLDG 1 Apn: 0040000900 - $257.15 Credit Card Fee $7.49 Credit Card Fee R000.369.908.00.00 0.00 $7.49 DEVELOPMENT $243.05 PERMIT FEE R000.322.100.00.00 0.00 $132.15 PLAN CHECK FEE R000.345.830.00.00 0.00 $85.90 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $25.00 TECHNOLOGY FEE $6.61 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R15449 R000.322.900.04.00 0.00 $6.61 $257.15 Date Paid: Monday, September 24, 2018 Paid By: EDGEWOOD APARTMENTS LLC Pay Method: CREDIT CARD 04261G Printed: Friday, September 21, 2018 4:38 PM 1 of 1 SYSTEMS ` Page 1 of 2 v1 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA 0017340000802374464500 Date: 09/21/2018 04:38:08 PM CREDIT CARD SALE VISA CARD NUMBER: **********1679 K TRAN AMOUNT: $257.15 APPROVAL CD: 04261G RECORD #: 000 CLERK ID: Rachelle X {CARDHOLDER'S SIGNATURE} I AGREE TO PAY THE ABOVE TOTAL AMOUNT ACCORDING TO THE CARD ISSUER AGREEMENT (MERCHANT AGREEMENT IF CREDIT VOUCHER) Thank you! Merchant Copy https://classic.convergepay.com/VirtualMerchant/transaction.do?dispatchMethod=printTra... 9/21/2018 Page 2 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 09/21/2018 04:38:08 PM CREDIT CARD SALE VISA CARD NUMBER: **********1679 K TRAN AMOUNT: $257.15 APPROVAL CD: 04261G RECORD #: 000 CLERK ID: Rachelle Thank you! Customer Copy https://classic.convergepay.comlVirtualMerchant/transaction.do?dispatchMethod=printTra... 9/21/2018 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: 3130 14/60 Iff Date Called: Specialinstructions: iti Date Wanted: -1-11— a.m. p.m. Requester: Phone No: proved per applicable codes. El Corrections required prior to approval. C I MMENTS: (41 -PRS (4472DILP4\ 0 Inspector: 'tl i fr n REINSPECTION E ' IRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date INSPECTION RECORD Retain a copy with permit INS NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 /t3 o30/ Project: WIG kkoo 49)11271 06 Type of Inspection: ` wJe, Address: �� 1-75c2 6 i gyff''p(/ �� Date Ca ed: Special Instructions:�` �` ;'' Date Wanted: 7s `pa.m. Requester: �JA1//1��'`�rs!'�-1 6 /�, Phone No: 353 -2E5s7 Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Naeaan trftAtt Z0:7 rt - Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. FILE COPY Permit No. b 3G Plan review approval is subject to errors and omissions. Approval of ccnstruction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: Dae: City of Tukwila BUILDING DIVISION i I SER.-V3ATE I1: REQUIRED FOR: ia chanicaJ C�'L'leCtric aJ plumbing ilMas Piping City of Tukwila B ••�l. ILPIN a DIVISION 4d oo 4SE2'wa00u)O dd E:00 � E -Q_ OFxNUN 0Cc�ON(� o (o EZQ NNU0(z,(S, OHZ(s, 0 Q 44 0 a4 oz OOOa44 up Q.00 46 at 4d HWU) 4.1 E•4 (1) E��,1OE.HxHN c) C) CD u° Ea (jr) (I)Ci) 0 Q 44 �, QO N cfloo H� Nis,�xis,� REVISIONS No changes shall be made to the scope of work without prior approval of ruto.rla Building Division NOTE. Fieviaions will require a new plan submittal and may include additional plan review fees. , C/) 0o o O H co H O x� upa H H w 00 a H<o 0 ��� 0.) WS'0 44 CEHHc0 �v)(�W — — — REVIEWED FOR CODE COMPLIANCE APPROVED OCT 11 2018 utr— City of Tukwila BUILDING DIVISION H z Cid ci) Ct 0•41 ca4 Off"' •r, 73 9 4C1:1)1_91 In W W ECEIVED CITY OF TUKWILA SEP 2 1 2018 PERMIT CENTER DI 0W1 1/ S 146th St 99 I SITE S 148th St X � miIi P2i I REVIEWED FOR CODE COMPLIANCE APPROVED OCT 11 2018 utr— City of Tukwila BUILDING DIVISION H z Cid ci) Ct 0•41 ca4 Off"' •r, 73 9 4C1:1)1_91 In W W ECEIVED CITY OF TUKWILA SEP 2 1 2018 PERMIT CENTER DI 0W1 REVIEWED FOR - CODE COMPLIANCE APPROVED OCT 11 2018 City of Tukwila BUILDING DIVISION WA 98168 •• �—J 714 � O co o (1.) 2 O X .8° Lc!) RECEIVED W riuDlciY OF TUKWILA SEP 2 1 2018 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED OCT 11 2018 City of Tukwila BUILDING DIVISION (I) � am *7..4 .d o0 $o �-' EIVED Itaillf TUKWILA Wan SEP 21 2018 ?ERMiT CENTER CD l J U,a r+ o o C'D 00 0 �, Ct 0-1 o tl Co CD CP t"F co 00 00 W • ki31N331114183d 8102 1 Z d3S V1Inn)Inl dO AJJO O3AI333t1 3RD FL. 2ND FL. IST FL. NOISIAIO ONIalIl8 EI!M)Inllo !O B;0Z 11100 a3AO2Iddtl 33NVIldWO0 3000 110-I 03M31A3a IIII!I111111 10111111111 OD III ED II II ED 111 OD NI OD ELI N I1 II 3RD F 2ND FL IST FL_ I1 I1 IDD III III, III II DO III -1 III II III OD ELI III I1 OD III III II EO OD ED OD II OD 11 OD 111 I ED OD 111 11 111 ED 11 11 11 111 111 III I 11 LEI OD I II EE I II CO OD EAST BLDG - WEST ELEv. 3/32'= 1'-0' ED I III II LEI 111 JI EL II III ED 1 1111 11 I 1 OD 11 III ED EE OD II -I OD 111 11 IST FL. OD II 11 II 111 CO 1 OD ED OD WEST BLDG - WEST ELEv. 3/32'= I'-0' OD III 1111 III II ED III III II III III EE II 111 ED 11 ® ® ® ED II 11 ED III 11 111 11 m I III ED OD II II 1111 111,1]111 m EAST BLDG- SOUTH ELEv. 3/32'= 1111111111 EXIST CMU 3RD FL. 1 1 2ND FL. ® ® i■ - - IST FL. OD II 11 II 111 CO 1 OD ED OD WEST BLDG - WEST ELEv. 3/32'= I'-0' OD III 1111 III II ED III III II III III EE II 111 ED 11 ® ® ® ED II 11 ED III 11 111 11 m I III ED OD II II 1111 111,1]111 m EAST BLDG- SOUTH ELEv. 3/32'= 1111111111 EXIST CMU 1^ Client Edgewood Apartments, LLC Mohammad Aminpour 3730 S 148th St Tukwilla, WA 98168 425-509146 phone fax SSS # I s1809018 Project Identification Edgewood Apartments SSS Engineers 3 WAC 196-23-070 Section Engineering Calculations 1 Calculations (Pages 1 - 3) 2 Repair Details (Pages. S1 - S3) REVIEWED FOR CODE COMPLIANCE APPROVED OCT 11 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA SEP 2 1 2018 PERMIT CENTER 24113 56th Ave W - Mountlake Terrace, WA 98043 - Ph: 425-778-1023 - Fax: 206-260-7490 D��- ool 51 d9a L h: Q f c) 9410.0._ /19 Cht-td1Q. 5f4W - 6' "0&c ' LAM 73r'r__,,' G .= ‘,711 hr.,, 9 L / P PF" = 0,13-7Cj /AiO ;-10 `�/ ) / / O /r�" A) (,= /0/A Yo) F= tot?U - "/` FeRce oA Oti79 pp. 0-4;: /53t07 6,5) /97 (6“1.9x. 3/31)- 0, e/A546,43-)( an') 0.5 kc-fr-in 24 - �- L-1( 5( (7e)Y. ;8yx1eo' O9' X 7�/? 5-x (9 3'3 btilf Vr0!K(66Y Ph:425-778-1023 - www.ssseng.com SOUND STRUCTURAL SOLUTIONS ENGINEERS Jsl�o9.'o116 y/i gi2�o1x3_-- 06) 60w/illy oQ Ft7=3.060 Vii," --/23o re -c,-1 6' =, ,s')4 3 $'6 .53,63m-& 3 Oim-n-C, wow{ PD = 6164) 12(,-; 2x1230 Pot s'- 3 p74 4)7 4 V FPS ill 53 `63/qtAl e7 0.1r 9h J, [ 44 (Q7)ak. Fc,2" .::"; coign_ yovki-7.3.00 Do) - *„.„.. 17 Fes ,,; F C C� _/6s06.;-, fro< -a,? /moo) , GP % ,11-0„,M1 !, t \a /, l3 ; 0, € 7K) zoo ,-, .: 1 p 771941" > z-pfae 5-/;$(-7 j� r' z. yP--ve 4Lx lS ?> c Ph: 425-778-1023 - www.ssseng.com SOUND STRUCTURAL SOLUTIONS 1_ t e10) .4 9.: ENGINEERS _rnigiLnel/c,/ PA -4e* - GAi/i -�►.- �' ° 17L-%" / O ',�1C- � - �= f l 'rc 401- fiLerbi7e Z-11) CAS4 9 5 ', 5 t,. -R Cm3 Frkr I, /» = ), 5 5 j) o (5) 016S r' % 0,667 ' zyap '? 0-4,4 1jZ ne) Ph:425-778-1023 - www.ssseng.com :0461-00,00.9 tp.pg _ Pale, / 71,131z4 Extsr. CONTATION, REffR TO SECTION 2/51 WHERE FIRST FLOOR GathAN HAS WOW wr. WATER PROOFING NAM*Ale OvER a.YWOOP SHEARON& Vy'AL <NAY MAN4 MARS & POST IN WALL, NO TIE ro PREVENT WALKWAY FROM A.L11162 AWAY FROM f5UILPIN& VE. ELEVATION Ph: 425-778-1023 - www.ssseng.com Fi>061/4 1-40,4 lpe/za/8 -r•z:rr.: c.x:.z::�_:z-,::2:;�.—r.:!.:/'x-z:�r�_�'ra-:r:rt;?::r::z_r.�'.�:'.-r.�y:z ADD A34 CLIP FROM BEAM TO WALL PLATE 0 EA. SIDE OF BEAM PJLT'-U' 2X4 641.1)MN rfii. N WALKWAY PDST, TYP. NOTE: SECTION OCCURS WHERE WALKWAY BEAM BEARS ON EXTERIOR WALL SI Ph: 425-778-1023 - www.ssseng.com SOUND STRUCTURAL SOLUTIONS ENGINEERS TO4J2 e-2 1:941e - EXIST. 5"WX7 DEEP GL COLUMN 5"W X 8" DEEP GL BEAM ACE4 POST CAP (CO EA. SIDE NEW 5"WX7 ,Y2ff DEEP GL COLUMN NOTE: SECTION OCCURS WHERE WALKWAY COLUMN HAS ROTTED AT THE LOWER LEVEL OF THE BUILDING. f 2 ; S1) 3/44-43' Ph: 425-778-1023 - wwwssseng.com R . -a Joint & Seam PROSOCO R -Guards Joint & Seam Filler is a gun - grade, crack and joint filler, adhesive and detailing compound that combines the best of silicone and polyurethane properties. This single -component, fiber -reinforced, Silyl-Terminated-Polymer (STP) is easy to gun, spread and tool. Use Joint & Seam Filler to fill openings and create transitions where flexible reinforcement is required to bridge larger gaps and provide continuous support of fluid -applied flashing membranes, waterproofing or air barrier components. Suitable for all climates, Joint & Seam Filler bonds directly to damp or dry surfaces and cures under a variety of weather conditions. It dramatically reduces surface preparation time by eliminating the need for reinforcing tapes at sheathing joints, inside and outside corners. Use Joint & Seam Filler as part of a continuous, building -wide air barrier system, or to prepare surfaces for conventional waterproofing or air barrier components. Joint & Seam Filler may also be used to repair cracks or fill voids after the primary R -Guard air barrier has been applied. ADVANTAGES • Streamlines preparation by eliminating the need for joint reinforcing tapes. • Silane functional polymer provides superior long term adhesion, crack filling and weathering characteristics. • Bonds to most common building materials without priming. • Single component saves time - no mixing. • Bonds and cures in wet weather and on damp substrates. Tolerates rain immediately after application. • May be fully exposed to UVand,, wg,Mr f 12 months. If long • Compatible with mo or air barrier comp Product Data Shee en s.APPROVED OCT 11 2018 Ci of Tukwila •�W isl Filler INDOOR ADVANTAGE GOLD BUILDING MATERIALS • Solvent free. Isocyanate free. Phthalate free. • No shrinkage. No staining. No yellowing. • Breathable - allows damp surfaces to dry. • Will not support mold growth. • Service temperatures from -75°F to 300°F (-59°C to 149°C). • Passes ASTM E84, Standard Test Method for Surface Burning Characteristics of Building Materials. • Illustration depicting the use of PROSOCO R -Guard® products are available at www.prosoco. com by downloading the R -Guard Installation Guidelines. !Mations • Not for use as a liquid flashing membrane. Use R -Guard FastFlash®. • Not for use in place of appropriate through -wall flashing. See R -Guard SS ThruWall product literature. • Not for use below grade or in locations which are continuously immersed in water. REGULATORY COMPLIANCE V0( Compliance R -Guard Joint & Seam Filler is compliant with the US Environmental Protection Agency's AIM VOC regulations. Visit www.prosoco.com/voccompliance to confirm compliance with individual district or state jurisdictions. SAFETY INFORMATION Always read full label and SDS for precautionary instructions before use. Use appropriate safety equipment and job site controls during application and handling. 24 -Hour EmergepCEIVED �'��� L A INFOTRAC at 8 - 5- 05 SEP 2 1 2018 PERMIT CENTER 041918 • ©2018 PROSOCO, Inc. • www.prosoco.com t?lS' Z9M Product Data Sheet R -Guard Joint & Seam Filler TYPICAL TECHNICAL DATA FORM SPECIFIC GRAVITY ...................... _........._................................................................ pH WT/GAL ................................................................................................... TOTAL SOLIDS viscous paste, mild odor pale red color 1.40 - 1.50 ...................................................................................................................... not applicable 11.8 lbs 99% VOC CONTENT ............................................................................. FLASH POINT 30 g/L maximum .................................................................................... no data FREEZE POINT ..... .......... . SHELF LIFE no data 1 year in tightly sealed, unopened container Cured Properties Hardness, Shore A Tensile Strength Elongation at Break* Water Vapor Transmission 40-50 70 psi >180% (ASTM D 412) 19 perms @ 20 mils ASTM E96 Corrosive Properties Non -corrosive *Elongation per ASTM D 412 is not a requirement of the Air Barrier Association of America's (ABAA) Acceptance Criteria for Liquid Applied Membranes nor is it a requirement of the International Code Council Evaluation Service's Acceptance Criteria for Water -Resistive Coatings used as Water -Resistive Barriers over exterior Sheathing (ICC -ES AC212). Elongation is not a requirement of the AAMA 714 Specification for Liquid Applied Flashing used to Create a Water -Resistive Seal Around Exterior Wall Openings. There is no data to support that certain levels of elongation must be achieved to perform as a fluid applied WRB or as a fluid applied flashing. Specifications should be based upon performance test results like those required from the referenced organizations. Refer to the R -Guard Joint & Seam Filler Product Test Results document for a complete list of performance test results. PREPARATION To ensure best results, apply to clean surfaces free of contaminants. Chemical residues, surface oxidation, surface coatings or films may adversely affect adhesion. Pressure -treated wood and other contaminated surfaces' should be cleaned with an Isopropyl Alcohol wipe and allowed to flash -off before application of R -Guard products. Concrete must be in place 3-7 days and free of any curing compounds or form release agents before permeable R -Guard products are applied. Mortar joints in CMU construction must have a minimum 3 day cure before being treated with R -Guard products. If considering use on insulated concrete forms, the preferred method for cleaning oxidation is with water and low-pressure cleaning. Protect people, vehicles, property, plants and all other surfaces not intended to receive Joint & Seam Filler. Remove and replace damaged sheathing. Any gaps or joints greater than 1 inch should be structurally repaired or readied for an appropriate transition membrane. In rough openings, and where appropriate, prepare all raw gypsum board edges with R -Guard PorousPrep. Apply to raw gypsum board edges in a thin, uniform coat according to published application instructions. Do not over apply. Allow to dry tack -free before application of R -Guard Joint & Seam Filler or other products. Roofing systems shall be capped and sealed or top of walls protected from water intrusion both before and after air barrier system installation. Water intrusion may interfere with bonding of air barrier waterproofing materials and /or detrimentally impact the performance of such materials. Surface & Air Temperatures Surface and ambient temperatures between 32°F (0°C) and 110°F (43°C) are required for proper curing and drying of material to take place. Hot Weather Conditions/Precautions: When air or surface temperatures exceed 95°F (35°C), apply product to the shady side of structure before daytime air and surface temperatures reach their peak. Hot surfaces may be cooled with a mist of fresh water. Keep containers closed and out of direct sunlight when not in use. Do not apply when substrate temperature exceeds 110°F (43°C) Cold Weather Conditions/Precautions: Product may be applied to frost -free substrates at temperatures below 32°F (0°C). Product will not begin to cure until temperatures reach 32°F (0°C) and remain above freezing. Keeping material stored in a heated environment prior to use and misting applied material with warm, fresh water will help in these conditions. Low Humidity Conditions The process of curing may take longer when lower humidity levels occur. A light misting of fresh water over the treated surface will accelerate curing if necessary. Though Joint & Seam Filler may be applied to damp surfaces and tolerates rain immediately after application, do not apply to surfaces with standing water or frost. Contact PROSOCO if conditions are questionable. Product Data Sheet • Page 2 of 4 • Item #70410 - 041918 • ©2018 PROSOCO, Inc. • www.prosoco.comtibk Product Data Sheet R -Guard Joint & Seam Filler Equipment Apply using a professional caulking gun. Use a DRY joint knife, trowel or spatula to tool and spread the product. Do not use soapy water when tooling or spreading. Storage & Handling Store in a cool, dry place. Keep container tightly closed when not dispensing. Do not open container until preparation work has been completed. Do not alter or mix with other chemicals. When stored at or below 80°F (27°C) R -Guard Joint & Seam Filler has a shelf life of 12 months after the date of manufacture. This shelf life assumes upright storage of factory -sealed containers. Do not double stack pallets. Dispose of unused product and container in accordance with local, state and federal regulations. APPLICATION Read "Preparation" and the Safety Data Sheet before use. Dilution & Mixing Apply as packaged. Do not dilute or alter, or use for applications other than specified. No mixing required. Typical Coverage Rates Coverage varies based on surface texture and irregularities. R -Guard Joint & Seam Filler is sold in 29 -oz tubes and 20 -oz sausages. Estimated coverage includes overlapping 1 -inch on each side of the sheathing joint. Joint width varies from 0 to 0.25 inches. • 60.5-93.5 lineal feet per 29 -oz tube • 38.5-60.5 lineal feet per 20 -oz sausage Application instructions PREPARE Prepare all surfaces as described above under "Preparation." Once preparation is complete, cut open tip of threaded fitting, install nozzle and cut nozzle to desired opening. Filling Joints, Seams and Cracks, Detailing Fastener Heads and Around Penetrations 1. Apply a bead of Joint & Seain Filler to all sheathing joints, seams and cracks, then strike smooth with a DRY tool. Joint widths up to 3/8 inch may be treated without backer rod. Treat joints ranging from 3/8 inch to 1 inch with backer rod before applying Joint & Seam Filler. Joints larger than 1 inch must be structurally improved or addressed with R -Guard SureSpan EX transition extrusion. Detail over wood knots, deep cracks or surface irregularities to complete the surface preparation. 2. Use a DRY joint knife, trowel or spatula to spread the product 1 inch beyond the sheathing seams on each side to a thickness of 20-30 mils. 3. Spot fastener heads and strike with a DRY tool. 4. Allow to skin before installing other waterproofing or air barrier components. Detailing' & Waterproofing Fastener Penetrations (Window & Door Penetrations) 1. Apply a bead of Joint & Seam Filler in each corner of the rough opening and at the sheathing to stud transition, then strike smooth with a DRY tool. Joint widths up to 3/8 inch may be treated without backer rod. Treat joints ranging from 3/8 inch to 1 inch with backer rod before applying Joint & Seam Filler. Joints larger than 1 inch must be structurally improved or addressed with R -Guard SureSpan EX transition extrusion. 2. Use a DRY joint knife, trowel or spatula to tool and spread product 1 inch beyond the seam on each side to a thickness of 20-30 mils. 3. Allow treated surfaces to skin over before installing R -Guard FastFlash®. PROTECT Apply R -Guard Spray Wrap, MVP, Cat 5", Cat 5' Rain Screen or other waterproofing or air barrier component pursuant to manufacturer instructions. TRANSITION Flashing Transitions 1. Fasten R -Guard SS ThruWall or other flashing leg to the vertical wall surface using a bead of Joint & Seam Filler or conventional methods. Fill any voids between the flashing leg and the vertical wall with Joint & Seam Filler. 2. Apply and tool Joint & Seam Filler as needed to direct water from the vertical wall to the face of SS ThruWall or other flashing. 3. Apply and tool Joint & Seam Filler at inside corners to ensure positive drainage. 4. Allow treated surfaces to skin before installing R -Guard FastFlash®. 5. Use Joint & Seam Filler to fill any remaining surface imperfections to provide positive drainage and continuous support of fluid -applied flashing membranes. REPAIR After applying R -Guard Spray Wrap MVP, Cat 51M, Cat 5'' Rain Screen, VB or other waterproofing or air barrier component, Joint & Seam Filler may be used to fill any cracks or voids to achieve a seamless, pinhole and void free coating. Product Data Sheet • Page 3 of 4 • Item #70410 - 041918 • ©2018 PROSOCO, Inc. • www.prosoco.com Product Data Sheet R -Guard Joint & Seam Filler Curing and Drying At 70°F (21 °C) and 50% relative humidity, product skins within 30 minutes and dries in 4 hours. Paintable with most paints after 2 hours. Joint & Seam Filler is moisture curing. Low temperatures and low relative humidity slow dry time. High temperatures and high relative humidity accelerate dry time. Cleanup Clean tools and equipment with mineral spirits or similar solvent immediately after use. Follow all safety precautions. Remove cured Joint & Seam Filler mechanically using a sharp -edged tool. WARRANTY The information and recommendations made are based on our own research and the research of others, and are believed to be accurate. However, no guarantee of their accuracy is made because we cannot cover every possible application of our products, nor anticipate every variation encountered in masonry surfaces, job conditions and methods used. The purchasers shall make their own tests to determine the suitability of such products for a particular purpose. PROSOCO, Inc. warrants this product to be free from defects. Where permitted by law, PROSOCO makes no other warranties with respect to this product, express or implied, including without limitation the implied warranties of merchantability or fitness for particular purpose. The purchaser shall be responsible to make his own tests to determine the suitability of this product for his particular purpose. PROSOCO's liability shall be limited in all events to supplying sufficient product to re -treat the specific areas to which defective product has been applied. Acceptance and use of this product absolves PROSOCO from any other liability, from whatever source, including liability for incidental, consequential or resultant damages whether due to breach of warranty, negligence or strict liability. This warranty may not be modified or extended by representatives of PROSOCO, its distributors or dealers. CUSTOMER CARE Factory personnel are available for product, environment and job -safety assistance with no obligation. Call 800-255-4255 and ask for Customer Care - technical support. Factory -trained representatives are established in principal cities throughout the continental United States. Call Customer Care at 800-255-4255, or visit our web site at www.prosoco.com, for the name of the PROSOCO representative in your area. • EST PRACTICES For best results, spread and tool Joint & Seam Filler while still wet, within 2-3 minutes of gun application. Hot Weather Conditions/Precautions: When air or surface temps exceed 95°F (35°C), apply product to shady side of structure before daytime air and surface temps reach their peak. Hot surfaces may be cooled with a mist of fresh water. Surfaces may be damp but must be free of standing water before application. Keep containers closed and out of direct sunlight when not in use. Do not apply when substrate temp exceeds 110°F (43°C). Cold Weather Conditions/Precautions: Product may be applied to frost -free substrates at temps below 32°F (0°C). Product will not begin to cure until temps reach and remain above 32°F (0°C). Low Humidity Conditions/ Precautions: Curing may take longer when lower humidity levels occur. A light misting of fresh water over the treated surfaces will accelerate curing, if necessary. For Cast -In -Place Concrete Applications, the concrete designated for application must be clean, smooth and free of curing compounds and form release agents. Repair bug holes, honey combing and other imperfections using a suitable cementitious mortar. Remove concrete splashes, over pours, grout or slurry rundown using appropriate mechanical means. Fill and prepare minor imperfections m the concrete surface with R -Guard Joint & Seam Filler. After application, inspect the surface to ensure the coating is applied at the appropriate wet mil thickness, achieving a continuous film and free of pinholes. Treat visible pinholes or breaks in the Min with additional primary air and water barrier coating or R -Guard FastFlash®. Roofing systems shall be capped and sealed or top of walls protected from water intrusion both before and after air barrier system installation. Water intrusion may interfere with bonding of air barrier waterproofing materials and /or detrimentally impact the performance of such materials. PROSOCO R -Guard® Joint & Seam Filler, FastFlash® and AirDam® are recommended for improved performance of R -Guard Spray Wrap MVP, VB, Cat 5" and Cat 5' Rain Screen water -resistive barrier coatings. Illustrations depicting the use of PROSOCO R -Guard' products are available at www.prosoco. com by downloading the R -Guard Installation Guidelines. To schedule field technical support, contact your PROSOCO Technical Customer Care toll- free at 800-255-4255. Field visits by PROSOCO personnel are for the purpose of making technical recommendations only. PROSOCO is not responsible for providing job site supervision or quality control. Proper application is the responsibility of the applicator. Product Data Sheet • Page 4 of 4 • Item #70410 - 041918 • ©2018 PROSOCO, Inc. • www.prosoco.com • .. PRODUCT TEST RESULTS R -Guard Joint & Seam Filler PROSOCO TEST METHOD CRITERIA RESULTS *Tensile Bond 1ASTM C 297 Minimum 15 psi (105 kPa) Pass *Freeze -Thaw ;ICC ES AC212 No cracking, checking, crazing, erosion, Pass delamination or other deleterious effects * No cracking, checking, crazing, erosion, Water Resistance ASTM D 2247 delamination, or other deleterious effects Pass *Water Penetration ASTM E 331 *Structural, Racking, ASTM E 1233A Restrained Environmental ASTM E 72 No cracking of the coating Pass Conditioning & Water ICC -ES AC212 Penetration ASTM E 331 No visible water penetration at sheathing joints as viewed from back of the panel *Weathering ICC -ES AC212 No cracking of the coating; no water AATCC2127 penetration *Air Leakage of Air Barrier ASTM E 2347 < 0.2 L / s•in2 at 75 Pa Assemblies (s 0.04 cfm / ft2 at 1.57 psf) Pass 0.0105 / s•m2 at 75 Pa (0.0021 cfm l ft' at 1.57 psf) *Fire Propagation Characteristics of Exterior Non -load-bearing Wall Assemblies Surface Burning Characteristics NFPA3 285 ASTM E 84 Must resist flame propagation and flame spread Criteria for ICC and NFPA Class A Building Material Flame Spread <_ 25 Smoke Developed <_ 450 Meets Class A Building Material Flame Spread: 15 Smoke Developed: 5 All testing was completed by independent, accredited laboratories. NOTES: 1. International Code Council Evaluation Service Acceptance Criteria 212 2. American Association of Textile Chemists and. Colorists 3. National Fire Protection Association 4. Southwest Research Institute Report No. 01.17421.01.001 Product Test Data • Page 1 of 1 • Item #70410 — 041918 • ©2018 PROSOCO, Inc. • www.prosoco.coin PRODUCT TEST RESULTS R -Guard Joint & Seam Filler MLLERiEDASpAr-REsisrivE,C PROSOCO ilk TRIM *Tensile Bond ASTM C 297 *Freeze -Thaw ICC -ES AC212 *Water Resistance *Water Penetration :*Structural, Racking, Restrained Environmental Conditioning & Water Penetration Weathering ASTM D 2247 ASTM E 331 ASTM E 1233A ASTM F 72 ICC -ES AC212 ASTM E 331 ICC -ES AC212 AATCC2127 ; penetration TtNGJAS WATER', 1V rEivap Minimum 15 psi (105 kPa) Pass No cracking, cher crazing, erosicm, Pass delaisin.ation or tither deleterious effects No cracking, checking, crazing, erosion, Pass delamthation., or other deleterious effects ry- n n No visible water penetration at sheathing joints Pass as viewed from back of the panel No cracking of the coating Pass No cracking of the coating; no water .t,c• , • , moor ;OF AttAss • ‘,.Air Leakage of Air Barrier ASTM E 2347 0 1,1 sin' at 75 Pa Assemblies 0.04 efrn at 1.57 psf) Pass *Fire Propagation Characteristics of Exterior NEPA285 Non -load-bearing Wall Assemblies Surface Burning Characteristics ASTM E 84 Smoke Developed 450 _ ....... „ .....„......„ Must resist flame propagation and flame spread Criteria fur ICC and NEPA Class A Building Material Flame Spread < 25 All testing was completed by independent. accredited laboratories. NOTES: 1. International Code Council Evaluation Service Acceptance Criteria 212 2. American Association of Textile Chemists arid Colorists 3. National Fire Protection Association 4. Southwest Research institute. Report No. 01.17421.01.001 Pass 0.0105 sm" at 75 Pa (0.0021. cfm ft" at 1.57 psf) Pass' Meets Class A Building Material Flame Spread: 15 Smoke Developed: 5 „ „„... Product Test Data • Page 1 of 1 • Item 070410 041918 • ()2018 PROSOCO, Inc. • www.prosoco.com FastFlash® PROSOCO R -Guard® FastFlash° is a waterproofing, adhesive and detailing compound for air barrier applications that combines the best characteristics of silicone and polyurethane. This single -component, Silyl-Terminated-Polymer (STP) is easy to gun, spread -and -tool, or roller apply to produce a highly durable, seamless, elastomeric flashing membrane. Allows for same day installation of windows, doors and other wall assembly, waterproofing or air barrier components. Suitable for all climates, FastFlash® bonds directly to damp or dry surfaces and cures under a variety of weather conditions. It dramatically reduces surface preparation time by eliminating the need for reinforcing tapes at sheathing joints, inside and outside corners. It simplifies the process of producing watertight details in new or existing construction. Use FastFlash® as part of a continuous, building - wide air barrier system, or to complement conventional waterproofing or air barrier components. Use FastFlash® to adhere, transition and counter -flash R -Guard SS ThruWall or other through -wall sheet flashing. ADVANTAGES • Available in Gun -Grade or Roller -Grade versions. • Streamlines preparation by eliminating the need for joint reinforcing tapes. • Silane functional polymer provides superior long term adhesion, crack bridging and weathering characteristics. • Easy 12-15 wet mil application. • Bonds to most common building materials without priming. • Single component saves time. • Produces a durable, weather -tight seal. • Bonds and cures in wet weather, on damp substrates, and tolerates rain immediately after application. • Will not tear or lose effectiveness when exposed to weather during construction. • May be fully exposed to UV and weather for up to 12 months. If longer, contact for inspection. INDOOR ADVANTAGE GOLD BUILDING MATERIALS • Compatible with most sealants and waterproofing or air barrier components. • Solvent free. Isocyanate free. Phthalate free. • No shrinkage. No staining. No yellowing. • Breathable - allows damp surface to dry. • Will not support mold growth. • Service temperatures: -75 to +300°F (-59 to +149°C). • Illustration depicting the use of PROSOCO R -Guard® products are available at www.prosoco. coin by downloading the R -Guard Installation Guidelines. Limitations • Not for use as a structural sealant. • Not for use in place of appropriate through -wall flashing. See R -Guard SS ThruWall product literature. • Not for use below grade or in locations designed to be continuously immersed in water. REGULATORY COMPL LANCE V0( Compliance R -Guard FastFlash® is compliant with the US Environmental Protectio regulations. Visit www.p to confirm compliance w state regulations. SAFETY INFORMATION Always read full label a instructions before use. equipment and job site c and handling. 24 -Hour Emergency INFOTRAC at 80gzotespe D CITY OF TUKWILA SEP 2 1 2018 PERMIT CENTER ( • Will A 'j�- ., oso . -t c� Foice DMPLiIAN E APPROVED 1• SDS fbqr11`6l!ary se appropriate safety ntrot f }r groalAtion UIL e.ING DIVISION Product Data Sheet • Page 1 of 5 • Item #70400-70405 - 122017 • ©2017 PROSOCO, Inc. • www.prosoco.com DI(‘ • no I } Product Data Sheet R -Guard FastFlash-''' T VPICAI TECHNICAL DATA FastFlash® FORM SPECIFIC GRAVITY pH viscous paste, mild odor red color 1.40 - 1.55 ...................................................................................................................... not applicable WT/GAL ...................................................................... TOTAL SOLIDS 11.75 - 12.5 lbs 99% VOC CONTENT ............................................................................. FLASH POINT 30 g/L maximum .................................................................................... >200° F (>93° C) FREEZE POINT SHELF LIFE not applicable 1 year in tightly sealed, unopened container Cured Properties Hardness, Shore A Tensile Strength Elongation at Break* Water Vapor Transmission 35-45 >150 psi >350% ASTM D 412 21 perms ASTM E 96 Corrosive Properties Non -corrosive *Elongation per ASTM D 412 is not a requirement of the Air Barrier Association of America's (ABAA) Acceptance Criteria for Liquid Applied Membranes nor is it a requirement of the International Code Council Evaluation Service's Acceptance Criteria for Water - Resistive Coatings used as Water -Resistive Barriers over exterior Sheathing (ICC -ES AC212). Elongation is not, a requirement of the AAMA 714 Specification for Liquid Applied'Flashing used to Create a Water - Resistive Seal Around Exterior Wall Openings. There is rio data t� support that certain levels of elongation must be achieved to perform as a fluid applied WRB or as a fluid applied flashing. Specifications should be based upon performance test results like those required from the referenced organizations. Refer to the R -Guard FastFlash® Product Test Results document for a complete list of performance test results. PREPARATION To ensure best results, apply to clean surfaces free of contaminants. Chemical residues, surface oxidation, surface coatings or films may adversely affect adhesion. Pressure -treated wood and other contaminated surfaces should be cleaned with an Isopropyl Alcohol wipe and allowed to flash -off before application of R -Guard products. Concrete must be in place 3-7 days and free of any curing compounds or form release agents before permeable R -Guard products are applied. Mortar joints in CMU construction must have a minimum 3 day cure before being treated with R -Guard products. If considering use on insulated concrete forms, the preferred method for cleaning is with water and low-pressure cleaning. Protect people, vehicles, property, plants and all other surfaces not intended to receive FastFlash®. Remove and replace damaged sheathing. In rough openings, and where appropriate, prepare all raw gypsum board edges with R -Guard PorousPrep. Apply to raw gypsum board edges in a thin, uniform coat according to published application instructions. Do not over apply. Allow to dry tack -free before application of R -Guard FastFlash® or other products. Any gaps or joints greater than 1 inch should be structurally repaired or readied for R -Guard SureSpan EX transition extrusion. Ensure positive drainage at all rough openings. Roofing systems should be capped and sealed or top of walls protected from water intrusion both before and after air barrier system installation. Water intrusion may interfere with bonding of air barrier waterproofing materials and/or detrimentally impact the performance of such materials. Surface & Air Temperatures Surface and ambient temperatures between 32°F (0°C) and 110°F (43°C) are required for proper curing and drying of material to take place. Hot Weather Conditions/Precautions: When air or surface temperatures exceed 95°F (35°C), apply product to the shady side of structure before daytime air and surface temperatures reach their peak. Hot surfaces may be cooled with a mist of fresh water. Keep containers closed and out of direct sunlight when not in use. Do not apply when substrate temperature exceeds 110°F (43°C). Cold Weather Conditions/Precautions: Product may be applied to frost -free substrates at temperatures below 32°F (0°C). Product will not begin to cure until temperatures reach 32°F (0°C) and remain above freezing. Keeping material stored in a heated environment prior to use and misting applied material with warm, fresh water will help in these conditions. Low Humidity Conditions/Precautions: The process of curing may take longer when lower humidity levels occur. A light misting of fresh water over the treated surface will accelerate curing if necessary. Product Data Sheet • Page 2 of 5 • Item #70400-70405 - 122017 • ©2017 PROSOCO, Inc. • www.prosoco.comTh' Product Data Sheet R -Guard FastFlash® Though FastFlash® may be applied to damp surfaces and tolerates rain immediately after application, do not apply to surfaces with standing water or frost. Contact PROSOCO if conditions are questionable. Equipment Reference the Gun -Grade or Roller -Grade Application Instructions for specific recommendations of appropriate equipment. Storage & Handling Store in a cool, dry place. Keep container tightly closed when not dispensing. Do not open container until preparation work has been completed. Do not alter or mix with other chemicals. When stored at or below 80°F (27°C) R -Guard FastFlash° has a shelf life of 12 months after the date of manufacture. This shelf life assumes upright storage of factory - sealed containers. Do not double stack pallets. Dispose of unused product and container in accordance with local, state and federal regulations. APPLICATION GUN -GRADE FASTFLASH Read "Preparation" and the Safety Data Sheet before use. Equipment Apply Gun -Grade FastFlash® using a professional caulking gun and spread with a DRY joint knife, trowel, or spatula. Do not use soapy water or solvent to help with the tooling process or to slick the surface profile. Dilution & Mixing Apply as packaged. Do not dilute or alter, or use for applications other than specified. No mixing required. Typical Coverage hates Coverage varies based on surface texture and irregularities. Gun -Grade R -Guard FastFlash° is sold in 29 oz tubes and 20 oz sausages. • 22-28 sq.ft. per 29 -oz tube applied at 12-15 mils • 15-17 sq.ft. per 20 -oz sausage applied at 12-15 mils Gun -Grade FastFlash Application Instructions Filling Joints, Seams and Cracks, Detailing Fastener Heads and Around Penetrations 1. Apply a bead of FastFlash® to all sheathing joints, seams and cracks and strike smooth with a DRY tool. Joint widths up to 1/4 inch may be treated with FastFlash'® without backer rod. Treat joints raining from 3/8 to 1 inch with backer rod and R -Guard Joint & Seam Filler. Joints larger than 1 inch must be structurally improved or addressed with R -Guard SureSpan EX transition extrusion. Detail over wood knots, deep cracks or surface irregularities to complete the surface preparation 2. Use a DRY joint knife, trowel or spatula to tool and spread the product beyond the sheathing seams on each side to a thickness of 12-15 mils. 3. Spot fastener heads and strike with a DRY tool. 4. Allow to skin before installing other waterproofing or air barrier components. Detailing & Waterproofing Rough Openings (Window and Door Penetrations) 1. Apply a bead of FastFlash° in each corner of the rough opening and at the sheathing -to - stud transition, then strike smooth with a DRY tool. Joint widths up to 1/4 inch may be treated with FastFlash'® and no backer rod. Treat joints ranging from 3/8 inch to 1 inch with backer rod and R -Guard Joint & Seam Filler. Joints larger than 1 inch must be structurally improved or addressed with R -Guard SureSpan EX transition extrusion. 2. Apply FastFlash° over the exterior inside framing of the rough opening and onto the exterior vertical wall surface 4-6 inches to create a 12-15 mil thick monolithic, pinhole - free flashing surface. NOTE When using with existing sheet weather resistive barriers, extend FastFlash® 8-10 inches over the face of the exterior wall to ensure positive drainage. 3. Allow treated surfaces to skin before installing windows, doors and other wall assembly, components. 4. Proceed to application of primary air and water barrier coating. NOTE: Gun -Grade FastFlash® may be used to detail joints, seams and cracks at 3/8 inch width or less; however, R -Guard Joint & Seam Filler is more commonly used for these applications. PROTECT Apply R -Guard Spray Wrap MVP, VB, Cat 5-, Cat 5T" Rain Screen or other waterproofing or air barrier component pursuant to manufacturer instructions. TRANSITION Flashing Transitions 1. Apply a minimum 3/8 -inch bead to the top edge of R -Guard SS ThruWall or other flashing leg and strike with a DRY joint knife or caulking tool. 2. Apply and spread additional FastFlash® to create a monolithic "cap flash" flashing membrane that extends 2 inches (51 mm) up the vertical face of the exterior wall and down over the fastener heads of the SS ThruWall Termination Bar. This "liquid termination bar" helps secure the flashing and ensures positive drainage from the wall surface to the flashing. Product Data Sheet • Page 3 of 5 • Item #70400-70405 — 120207 • ©2017 PROSOCO, Inc. • www.prosoco.com Product Data Sheet R -Guard FastFlash® REPAIR After applying R -Guard Spray Wrap MVP, Cat 5-, Cat 5'" Rain Screen, VB or other waterproofing or air barrier component, FastFlash® may be used to fill any cracks or voids to achieve a seamless, pinhole and void free coating. APPLICATION ROLLER -GRADE FASTFLASII Read "Preparation" and the Safety Data Sheet before use. Equipment Apply Roller -Grade version with a professional paint roller with a 3/8 -inch nap. Do not use soapy water or solvent to help with tooling or to slick the surface profile. Dilution & Mixing Apply as packaged. Do not dilute or alter, or use for applications other than specified. Using a low -speed drill and paddle, mix well from top to bottom and side-to-side for a minimum of 3 minutes before use. Avoid mixing air into the product. Once opened, product should be used immediately. Typical Coverage Rates Coverage varies based on surface texture and irregularities. Roller -Grade FastFlash® is sold in 2 -gallon pails. • 50-100 sq.ft. (5-9 sq.m.) per gallon applied at 12-15 mils Roller -Grade FastFlash' Application Instructions Filling Joints, Seams and Cracks Roller -Grade FastFlash® is not for use in filling joints, seams and cracks. Reference Application Instructions for Gun -Grade FastFlash® in this document. Detailing & Waterproofing Rough Openings (Window and Door Penetrations) 1. Apply a bead of Gun -Grade FastFlash® in each corner of the rough opening and at the sheathing - to -stud transition, then strike smooth with a DRY tool. Joint widths up to 1/4 inch may be treated with Gun -Grade FastFlash® and no backer rod. Treat joints ranging from 3/8 inch to 1 inch with backer rod and R -Guard Joint & Seam Filler. Joints larger than 1 inch must be structurally improved or addressed with R -Guard SureSpan EX transition extrusion. 2. Apply Roller -Grade FastFlash` over the exterior inside framing of the rough opening and onto the exterior vertical wall surface 4-6 inches to create a 12-15 mil thick monolithic, pinhole - free flashing surface. NOTE When using with existing sheet weather resistive barriers, extend FastFlash® 8-10 inches over the face of the exterior wall to ensure positive drainage. 3. Allow treated surfaces to skin before installing windows, doors and other wall assembly, components. 4. Proceed to application of primary air and water barrier coating. NOTE: Gun -Grade FastFlash® may be used to detail joints, seams and cracks at 3/8 inch width or less; however, R -Guard Joint & Seam Filler is more commonly used for these applications. PROTECT Apply PROSOCO R -Guard® Spray Wrap MVP, VB, Cat 5T", Cat 5" Rain Screen or other waterproofing or air barrier component pursuant to manufacturer instructions. TRANSITION Flashing Transitions 1. Apply a minimum 3/8 -inch bead of Gun -Grade FastFlash'® to the top edge of R -Guard SS ThruWall or other flashing leg. Strike with a DRY joint knife or caulking tool. 2. Apply Roller -Grade FastFlash® to create a monolithic "cap flash" flashing membrane that extends 2 inches (51 mm) up the vertical face of the exterior wall and down over the fastener heads of the SS ThruWall Termination Bar. This "liquid termination bar" helps secure the flashing and ensures positive drainage from the wall surface to the flashing. REPAIR After applying R -Guard Spray Wrap MVP, Cat 5'", Cat 5'"` Rain Screen, VB or other waterproofing or air barrier component, FastFlash® may be used to fill any cracks or voids to achieve a seamless, pinhole and void free coating. CURING & DRYING At 70°F (21°C) and 50% relative humidity, product skins within 30-60 minutes and dries in 4-6 hours. Best practice is to use the entire pail of Roller -Grade FastFlash® once opened. Keep containers closed and out of direct sunlight when not in use. If product skins between applications, remove skin and re -mix product before applying as recommended. FastFlash® is moisture curing. Low temperatures and low relative humidity slow dry time. High temperatures and high relative humidity accelerates dry time. Product Data Sheet • Page 4 of 5 • Item #70400-70405 — 122017 • ©2017 PROSOCO, Inc. • www.prosoco.com Product Data Sheet R -Guard FastFlash® Cleanup Clean tools and equipment with mineral spirits or similar solvent immediately after use. Follow all safety precautions. Remove cured FastFlash° mechanically using a sharp -edged tool. WARRANTY The information and recommendations made are based on our own research and the research of others, and are believed to be accurate. However, no guarantee of their accuracy is made because we cannot cover every possible application of our products, nor anticipate every variation encountered in masonry surfaces, job conditions and methods used. The purchasers shall make their own tests to determine the suitability of such products for a particular purpose. PROSOCO, Inc. warrants this product to be free from defects. Where permitted by law, PROSOCO makes no other warranties with respect to this product, express or implied, including without limitation the implied warranties of merchantability or fitness for particular purpose. The purchaser shall be responsible to make his own tests to determine the suitability of this product for his particular purpose. PROSOCO's liability shall be limited in all events to supplying sufficient product to re -treat the specific areas to which defective product has been applied. Acceptance and use of this product absolves PROSOCO from any other liability, from whatever source, including liability for incidental, consequential or resultant damages whether due to breach of warranty, negligence or strict liability. This warranty may not be modified or extended by representatives of PROSOCO, its distributors or dealers. CUSTOMER CARE Factory personnel are available for product, environment and job -safety assistance with no obligation. Call 800-255-4255 and ask for Customer Care - technical support. Factory -trained representatives are established in principal cities throughout the continental United States. Call Customer Care at 800-255-4255, or visit our web site at www.prosoco.com, for the name of the PROSOCO representative in your area. BEST PRACTICES Roofing systems should be capped and sealed or top of walls protected from water intrusion both before and after air barrier system installation. Water intrusion may interfere with bonding of air barrier waterproofing materials and/or detrimentally impact the performance of such materials. For best results, spread/tool Gun -Grade FastFlash° while still wet, within 2-3 minutes of gun application. Hot Weather Conditions/Precautions When air/ surface temps exceed 95°F (35°C), apply product to the shady side of structure before daytime air and surface temps reach their peak. Hot surfaces may be cooled with a mist of fresh water. Keep containers closed and out of direct sunlight when not in use. Do not apply when temp exceeds 110°F (43°C). Cold Weather Conditions/Precautions: May be applied to frost -free substrates at temps below 32°F (0°C). Product will not begin to cure until temps reach 32°F (0°C) and remain above freezing. Low Humidity Conditions/Precautions: Curing may take longer when lower humidity levels occur. A light misting of fresh water over the treated surface will accelerate curing, if necessary. Gun -Grade FastFlash® may be used to adhere and gasket mechanically fastened building components. For Cast -In -Place Concrete Applications, the concrete designated for application must be clean, smooth and free of curing compounds and form release agents. Repair bug holes, honey combing and other imperfections using a suitable cementitious mortar. Remove concrete splashes, over pours, grout or slurry rundown using appropriate mechanical means. Fill and prepare minor imperfections in the concrete surface with R -Guard Joint & Seam Filler. After product application, inspect the surface to ensure the coating is applied at the appropriate wet mil thickness, achieving a continuous film and free of pinholes. Treat visible pinholes or breaks in the film with additional primary air and water barrier coating or R -Guard FastFlash°. PROSOCO R -Guard® Joint & Seam Filler, FastFlash° and AirDam® are recommended for improved performance of all R -Guard air- and water -resistive barrier coatings. Use Gun -Grade FastFlash° after the primary R -Guard air barrier has been applied to repair cracks or fill voids. Illustration depicting the use of PROSOCO R -Guard® products are available at www.prosoco.com by downloading the R -Guard Installation Guidelines. To schedule field technical support, contact your PROSOCO Technical Customer Care toll- free at 800-255-4255. Field visits by PROSOCO personnel are for the purpose of making technical recommendations only. PROSOCO is not responsible for providing job site supervision or quality control. Proper application is the responsibility of the applicator. Product Data Sheet • Page 5 of 5 • Item #70400-70405 - 122017 • ©2017 PROSOCO, Inc. • www.prosoco.com PRODUCT TEST RESULTS R -Guard FastFlash® RFZOSOCC) TEST METHOD Adhesive Strength to Substrates ASTM C 794 (RITERIA 5 pli RESULTS Pass Water Penetration Around Nails Modified ASTM D 1970 Shall pass 31 mm (1.2 in) of water AAMA 711 Section 5.3 Pass Accelerated 17V Aging Peel Adhesion Appearance ASTM G 154, UVA cycle 1 ASTM C 794, Visual 5 pli Pass Elevated Temperature Exposure, Level 3=176° F for 7 days AAMA 711 ASTM C 794 5 pli Pass Thermal Cycling (10 cycles) Peel Adhesion AAMA 711 ASTM C 794 5 pli Pass Crack Bridging ASTM C 1305 Water holdout of 550 millimeters for 24 hours with 1/8 -inch crack after Pass cycling per ASTM C 1305 for 10 cycles. Water Immersion AAMA 711 ASTM C 794 5 pli Pass Water Vapor Permeability ASTM E 96 Wet Cup Minimum of 10 perms at manufacturer's recommended application thickness Pass - 21 perms Damp Surfaces *Tensile Bond ASTM C 794 -411111,0114Mtr RaosiggillgrAA 4111#31119:. 5 pli Pass ASTM C 297 Minimum 15 psi (105 kPa) *Freeze -Thaw ICC -ES AC212 No cracking, checking, crazing, erosion, delamination or other deleterious effects Pass Pass *Water Resistance *Water Penetration *Weathering ASTM D 2247 ASTM E 331 ICC -ES AC212 AATCC2 127 *Air Leakage of Air Barrier Assemblies ASTM E 2357 No cracking, checking. crazing, erosion, delamination or other deleterious effects No visible water penetration at sheathing joints as viewed from back i Pass of the panel. No cracking of the coating: no water Pass Pass penetration. 7,..litZregaq 5. 0.2 L / s:m2 at 75 Pa (5 0.04 cfm / ft2 at 1.57 psf) Surface Burning Characteristics ASTM E 84 Criteria for ICC and NFPA Class A Building Material: Flame Spread 5. 25 Smoke Developed 5 450 Pass: 0.0105 L / som2 at 75 Pa (0.0021 cfm / ft2 at 1.57 psf) Meets Class A Building Material Flame Spread: 15 Smoke Developed: 10 Surface Burning Characteristics of Building Materials and Assemblies (Canada) CAN/ULC S102-10 N/A Flame Spread Rating: 5 Smoke Developed Classification: 25 All testing was completed by independent, accredited laboratories. Test results are applicable to both gun -grade and roller -grade versions of R -Guard FastFlash'. NOTES: 1. International Code Council Evaluation Service Acceptance Criteria 212 2. American Association of Textile Chemists and Colorists Product Test Data • Page 1 of 1 • Item #70400-70405 - 122017 • ©2017 PROSOCO, Inc. • www.prosoco.com PRODUCT TEST RESULTS R -Guard FastFlash® RF OSOCO Adhesive Strength to Substrates Water Penetration Around Nails Accelerated UV Aging Peel Adhesion Appearance Elevated Temperature Exposure, Level 3=176' F for 7 days Thermal Cycling (10 cycles) P-. Peel Adhesion Crack Bridging Water Immersion Water Vapor Permeability Damp Surfaces ASTM C 794 Modified ASTM D 1970 AAMA 711 Section 5.3 ASTM G 154, UVA cycle 1 ASTM C 794, Visual AAMA 711 ASTM C 794 AAMA 711 ASTM C 794 ASTM C 1305 AAMA 711 ASTM C 794 ASTM E 98 Wet Cup ASTM C 794 5 pli Shall pass 31 nun (1.2 in) of water ?5p1i 5p1 Pass Pass Pass Pass Water holdout of 550 millimeters fbr 24 hours with 1/8 -inch crack after Pass cycling per ASTM C 1305 for 10 cycles. ', z5pli i Minimum of 1.0 perms at manufacturer's recommended application thickness z5ph Pass Pass - 21 perms Pass�-.- ,*Tensile Bond *Freeze -Thaw *Water Resistance *Water Penetration *Weathering ASTM C 297 ICC -ES AC212 ASTM D 2247 1ASTME331 ICC -ES AC212 AATCC' 127 Minimum 15 psi (105 kPa) No cracking, checking crazing erosion, delamination or other deleterious effects No cracking, checking crazing erosion, delamination or other deleterious effects No visible water penetration at sheathing joints as viewed from back of the panel. No cracking of the coating: no water penetration. Pass Pass Pass Pass *Air Leakage of Air Barrier Assemblies ASTM E 2357 <0.2.L/s.n2at75Pa (< 0.04 cfm / ft' at 1.57 psf) Surface Burning Characteristics ASTM E 84 Surface Burning Characteristics i of Building Materials and Assemblies (Canada) CAN/UI,C S102-10 Criteria for ICC and NEPA Class A I Building Material: Flame Spread < 25 I Smoke Developed s 450 N/A All testing was completed by independent, accredited 'abort ries. Test results are applicable to both gun -prude and roller- to NOTES: 1. International Code Council Evaluation Service Acceptance Criteria 212 2. American Association of Textile Chemists and Colorists Pass: 0.0105 L / s -m2 at 75 Pa (0.0021 cfm / ft2 at 1.57 psf) Meets Class A Building Material ; Flame Spread: 15 Smoke Developed: 10 Flame Spread Rating: 5 Smoke Developed Classification: 25 .ersions of R -Guard FastFlash' Product Test Data • Page 1 of 1 • Item #70400-70405 122017 • 112017 PROSOCO, Inc. • www.pros0co.com EXHIBIT A EDGEWOOD APARTMENTS 3730 South 148th Street Tukwila, WA 98168 (206) 246-3269 September 17, 2018 r Lav All the following repairs and replacements are in kind with the existing. There are about 60 columns and 100 beams that are connected to these columns to support the walkways on the premises. About 4-5 of these beam -column connections have developed dry -rot and need to be fixed. The columns are being repaired at these locations and the beams are being replaced. The structural engineering calculations for the repair of these beams and columns are enclosed. The beams and columns will be repaired/replaced according to accompanying drawings. Also there are some fascia boards at and around these beam -column locations that are cracked and delapidated that are also being repaired/replaced at the same time. REVIEWED FOR CODE COMPLIANCE APPROVED OCT 11 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA SEP 2 1 2018 PERMIT CENTER 5/31/2019 0 O City of Tukwila Department of Community Development MOHAMMAD AMINPOUR 3730 S 148TH ST - OFFICE TUKWILA, WA 98168 RE: Permit No. D18-0301 EDGEWOOD APARTMENTS 3730 S 148TH ST Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 7/24/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 7/24/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sinnerely, t ndace Nichols Permit Technician File No: D18-0301 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT CORD COP? e) PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0301 DATE: 09/25/18 PROJECT NAME: EDGEWOOD APARTMENTS SITE ADDRESS: 37300 S 148TH ST X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: --)Jo Building Division 11 Public Works Fire Prevention Structural El Planning Division El ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 09/27/18 Not Applicable ❑ Structural Review Required (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: 10/25/18 ❑ Approved with Conditions Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 c CITY OF TUKWILA Department of Community Development 630o Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-3670 FAX (206) 431-3665 E-mail: tukplanOci.tukwila.wa.us Permit Center/Building Division 206 431-3670 Public Works Department 206 433-0179 Planning Division 206 431-3670 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION STATE OF WASHINGTON) ) ss. COUNTY OF KING ) Vi Lw!M641 A»it'& [please pname , states as follows: PERMIT NO: 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.09,3 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number _13, and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. Signed aid sworn to before me this NOTARY PUBLIC in and for the State of Washington Residing at County Name as commissioned: �S �FLti (�f i �- { l My commission expires: �o- n rao19 18.27.090 Exemptions. The registration provisions of this 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile/manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW who shall warranty service and repairs under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed O chapter do not apply to: by a registered contractor; 11. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile/manufactured home dealer or manufacturer who subcontracts the installation, set-up, or repair work to actively registered contractors. This exemption only applies to the installation, set-up, or repair of the mobile/manufactured homes that were manufactured or sold by the mobile/manufactured home dealer or manufacturer; 18. An entity who holds aValieelectrical contractor's license under chapter'i9:283RCWtthat employs a certified journeyman electrician; a certified residential specialty electrician, or an`electrica ' rain'eEtneetingthe requirements of:chapter'i9.28" RCW to perform plumbing work that is incidentally, directly,'-ansd iitnecliately appropriate to thelikkjiAigd repla&einentof a household appliance or other small household utilization equipment that requires limited elect-ric'pdwer�and Hinted waste and/or water conncctioi>s. A.n clecttical trainee must be supervised by a certified electrician while performing plumbing work. • Per Washington State Department of Labor and Industries lessee has been interpreted to be equivalent to owner for purposes of exemptions.