Loading...
HomeMy WebLinkAboutPermit D18-0302 - SOUTHCENTER COMMUNITY BAPTIST - REMODELSOUTHCENTER COMMUNITY BAPTIST CHURCH 14742 MACADAM RD S EXPIRED 05/25/2019 D18-0302 C w9sz City of Tukwila 2° i8 Parcel No: Address: Project Name: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 7661600211 14742 MACADAM RD S DEVELOPMENT PERMIT Permit Number: D18-0302 Issue Date: 11/14/2018 Permit Expires On: 5/13/2019 SOUTHCENTER COMMUNITY BAPTIST CHURCH Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: TUKWILA BAPTIST CHURCH 14742 MACADAM RD S , TUKWILA, WA, 98188 JEREMY SHORT 5422 16TH AVE SW , SEATTLE, WA, 98106 AFFIDAVIT - JEREMY SHORT SOUTHCENTER COMMUNITY BAPTIST CHURCH 14742 MACADAM RD S , TUKWILA, WA, 98168 Phone: (206) 618-6075 Phone: Expiration Date: DESCRIPTION OF WORK: REMODEL EXISTING RESIDENCE. REPLACE 8 WINDOWS, REPLACE KNOB AND TUBE WIRE, SLATE AND PLASTER WITH 1/2" DRYWALL, REPLACE KITCHEN CABINETS, FLOORING, INTERIOR DOORS, INSTALL INSULATION THROUGHOUT, REPLACE 2 DRAINS IN KITCHEN, SINK DRAIN AND WASHING MACHINE DRAIN. SEE ATTACHMENTS FOR PHOTOS OF NEW INSTALLED WINDOWS. Project Valuation: $14,000.00 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: Electrical Service Provided by: TUKWILA Fees Collected: $657.35 Occupancy per IBC: A-3 Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 l) National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Number: 0 Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No Volumes: Cut: 0 Fill: 0 Permit Center Authorized Signature: Date: 1(-[1-4-fg I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local la r:gulating construction or the performance of work. I am authorized to sign and obtain this development er and agree to t ..nditions attached to this permit. Signatur Print ar'e: Date: // —1(/ — O This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0409 FRAMING 0606 GLAZING 0601 WALL INSULATION CITY OF TUKA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Per "fiit No. Project No. nt Date Application Accepted: Date Application Expires: '7) (For office use mly) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 14742 MacAdam Rd S King Co Assessor's Tax No.: Suite Number: Floor: Tenant Name: Southcenter Community Baptist Church New Tenant: ❑ Yes ..No PROPERTY OWNER Name: Southcenter Community Baptist Church Address: 14742 MacAdam Rd S City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Jeremy Short Address: 5422 16th Ave SW 0414c, Mt, .~ Rd- -5- City: Seattle State: WA zip: 98106 Phone: (206) 618-6075 Fax: Email: nwsoundguy@gmail.com State: GENERAL CONTRACTOR INFORMATION Company Name: Owner Company Name: None 0414c, Mt, .~ Rd- -5- Address: Architect Name: City: State: Zip: Phone: Fax: Phone: Fax: Contr Reg No.: Email: Exp Date: Tukwila Business License No.: H:\Applicatioro\Fornts-Applications On Line\201 1 Applications\Pennit Application Revised - 8-9-1 Ltlocx Revised: August 2011 bh ARCHITECT OF RECORD Name: k Company Name: None 0414c, Mt, .~ Rd- -5- City: City: -41"4w' 1 ti Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Name: k Company Name: None 0414c, Mt, .~ Rd- -5- City: City: -41"4w' 1 ti Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: k Address: /y7 y Z 0414c, Mt, .~ Rd- -5- City: City: -41"4w' 1 ti State: 1✓.4 Zip: ?&.J 4P, Page of 4 BUILDING PERMIT INFORMATIC 206-431-3670 Valuation of Project (contractor's bid price): $ 14,000 Existing Building Valuation: $ 225,000 Describe the scope of work (please provide detailed information): Remodel existing residence, Replace 8 windows, replace knob and tube wire, replace slate and plaster with 1/2" drywall, replace kitchen cabinets, replace flooring, replace interior doors, install insulation troughout, replace 2 drains in kitchen, sink drain and washing machine drain. Will there be new rack storage? ❑ Yes pi.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Lorns-Applications On Line \201 I Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 nn Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC l st Floor 968 968 0 0 2"d Floor 3`d Floor Floors thru Basement 700 0 0 0 Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Lorns-Applications On Line \201 I Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 nn Page 2 of 4 PUBLIC WORKS PERMIT INFcIATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑... Water District #125 0 ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate ❑ .. Highline O ...Valley View ❑ .. Renton ... • Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") 0 ...Technical Information Report (Storm Drainage) 0 ...Bond 0 .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way ❑ . Non Right-of-way 0 ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities 0 ...Frontage Improvements 0 ...Traffic Control 0 ...Backflow Prevention - Fire Protection Irrigation Domestic Water 0 .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑...Traffic Impact Analysis ❑... Hold Harmless — (SAO) ❑ ... Hold Harmless — (ROW) 0 .. Right-of-way Use - Profit for less than 72 hours 0 .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone 0 .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut 0 .. Looped Fire Line ❑ ...Permanent Water Meter Size... WO # 0 ...Temporary Water Meter Size .. WO # ❑ ...Water Only Meter Size WO # ❑ ...Sewer Main Extension Public ❑ Private ❑ ❑ ...Water Main Extension Public 0 Private 0 ❑ .. Grease Interceptor 0 .. Channelization 0 .. Trench Excavation 0 .. Utility Undergrounding ❑...Deduct Water Meter Size FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) 0 ...Water 0 ...Sewer Monthly Service Billing to: Name: 0 ...Sewage Treatment Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip H:\Applications\forms-Applications On Linc\2011 Applications\Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Page 3 of 4 ArA PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O E ' OR AUTHO r I rZ GE Signature: Date: 09/24/2018 Print Nater my Short Day Telephone: (206) 618-6075 Mailing Address: 5422 16th Ave SW H:\Applications\Forms-Applications On Line \201 1 Applications \Permit Application Revised - 8-9-I1.docx Revised: August 2011 bh Seattle WA 98106 City State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $657.35 D18-0302 Address: 14742 MACADAM RD 5 Apn: 7661600211 $657.35 DEVELOPMENT $638.75 PERMIT FEE R000.322.100.00.00 0.00 $371.97 PLAN CHECK FEE R000.345.830.00.00 0.00 $241.78 WASHINGTON STATE SURCHARGE 6640.237.114 0.00 $25.00 TECHNOLOGY FEE $18.60 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R15451 R000.322.900.04.00 0.00 $18.60 $657.35 Date Paid: Monday, September 24, 2018 Paid By: SOUTHCENTER COMMUNITY BAPTIST Pay Method: CHECK 12958 Printed: Monday, September 24, 2018 9:17 AM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 DIS e2-30z— Project: 3QL Project: vi,Xi ceAcit(t,S-r Type of Inspection: T- 0 Address: e4711 *Awl fill- S• Date Called: Special Instructions: Date Wanted: 41-26 Q, 1 8 p.m. Requester: Phone No: ❑ Approved per applicable codes. COMMENTS: Corrections require • • r to approval. r '7'Ot fitJS t( c,a✓cc� ndev25 2S dscs"J XJ—aceMffek is C. Inspector: Date: Visio/20e REINSPECTION FEE REQUIRED. Prior to next inspec. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION !)k8 0302, 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: I aArrdfL 4 w A,tyar Type of Inspection: c> i /E i at7ZiL- Address: /y9//i ,4AC Oen t?o .S - Date lied: Special Instructions: Date Wanted: 1/Zl-e a.m. Requester: Phone No: Approved per applicable codes. IXICorrections required prior to approval. COMMENTS: /A3*(4: ` Gr A/o� JO /0 a vek-m-Gde.r. ow_c_ gi\LI, Inspector: ".... REINSPECTION FEE REQUIRED. Prior to next insy4ction, fie must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 4/1/2019 w 0 0 y� City of Tukwila ° Department of Community Development JEREMY SHORT 5422 I6TH AVE SW SEATTLE, WA 98106 RE: Permit No. D 18-0302 SOUTHCENTER COMMUNITY BAPTIST CHURCH 14742 MACADAM RD S Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 5/25/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If itis determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 5/25/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, 0✓itC Ka dace Nichols Permit Technician File No: D18-0302 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 r:PERMiT COORD COPY o PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0302 DATE: 09/26/18 PROJECT NAME: SOUTHCENTER COMMUNITY BAPTIST CHURCH SITE ADDRESS: 14742 MACADAM RD S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: A-wc, bunging Division 335 OP -62_74 Atik q1/4)-7-16 Fire Prevention C21 Structural vs �9-P Planning Division l D -).do -(o ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: Not Applicable ri (no approval/review required) REVIEWER'S INITIALS: DATE: 09/27/18 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Notation: 0 DUE DATE: Approved with Conditions Denied (ie: Zoning Issues) 10/25/18 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg D Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-367o FAX (206) 431-3665 E-mail: tukplan@ ci.tukwila.wa.us Permit Center/Building Division 206 431-3670 Public Works Department 206 433-0179 Planning Division 206 431-367o AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION STATE OF WASHINGTON) COUNTY OF KING ss. er ��'" .S�oC`)— , states as follows: [please print name] PERMIT NO: l - C3 302 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number(5 , and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. , t er/0,��$ I understand that I may be waiving certain rights that I, :: t otherwise have under state law in any decision to engage an unregistered contractor to perform const on work. \\�.\\\\"\\1itt R\E A W,e:stb 0 S- r • .. N i i i i1 �i A4/B$_\o Z //// "7,s, 1''„'529.21= � WAS ‘4.4 \!\. er's Agent* Signed and sworn to before me this day of /O11eGiv6e 4c , 20 / . Nb1 Y PUBLIC in and for the State of Washington Residing at r/9 , County Name as commissioned: /'(ZU4 `L T9-(„vh My commission expires: 0 5Iae /aa r-, 18.27.090 Exemptions. The registration provisions of this chapter do not apply to: 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile/manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW who shall warranty service and repairs under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile/manufactured home dealer or manufacturer who subcontracts the installation, set-up, or repair work to actively registered contractors. This exemption only applies to the installation, set-up, or repair of the mobile/manufactured homes that were manufactured or sold by the mobile/manufactured home dealer or manufacturer; 18. An entity who holds a electrical contractor's license under chapter 19.28 RCW,that employs a certified journeyman electrician,a certified residential specialty electrician, or an electrical trainee meeting the requirements of chapter,19.28,RCW to perform plumbing work that is incidentally, directly, and immediately appropriate to the like -in-kind replacement of a household appliance or other small household utilization equipment that requires limited electric power and limited waste and/or water connections. An electrical trainee must be supervised by a certified electrician while performing plumbing work. • Per Washington State Department of Labor and industries lessee has been interpreted to be equivalent to owner for purposes of exemptions. Description of Work to be completed. All work to be completed on Main Floor Only No framing work to be completed other than replace any broken or damaged boards. 1. Replace 8 windows as indicated on Plans 2. Remove Slate and Plaster install R-13 insolation in outside walls 3. Install 1/2" Drywall, Tape, Sand and texture 4. Replace Kitchen Cabinets 5. Replace Floors 6. Replaced 4 Interior Doors 7. Replace 2 drains lines and manifold vents in attic above kitchen 8. Replace knob and tube wiring with 12 gauge romex 9. Blow in insulation in attic Index P000 — Index/Description of Project P001 — Site Plan P002 — Main Floor P003 — Basement P004 - Elevation m# 212W Southcenter Community Baptist Church House PLANNING APPROVED No changes can be made to these plans without approval from the Planning Division of DOD Bri M q Date l6# -N' PE_Ti SIT 1.17,2Uci17D FOR: IJ v�^.riian�c ''!vctncal' Cif F tubing Cas Piping C ;y of Tukwlta i gi .TIG DIVISION 14742 Macadam Rd S. Tukwila, WA 98168 REVISIONS Na changes shalt be made to the scope of work without prior approval of + 1-71.0+--,'':i E�ildin tC%: f, g Division v.:ions will require a new plan sub mi tat and may inc'ude adrtional plan review fes, FILE COPY Permit No. br $-- 030 2 Pian review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field .py and co di ns is acknowledged: By: Dat I/ —(L/ —)r City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED OCT 2920113 City of Tukwila BUILDING DIVISION MAY 21.20 D RECEIVED CITY OF TUKWILA SEP 2 4 2018 PERMIT CENTER Drawing # SCBC P000 Index Date 8/31/2018 496.1' Nflail "IBJ (212010. • �.1 T ' li 4) z II D, Lc 0.1 X V) W 0 0 1 Milt.r.r. w.r SITE PLAN 1/16.1" 11_10" fel-.'.5.13' '''14 OTTc1,1 OF SLOPE L_GAL DESCRIPTION: N 1/2 OF TRACT 12, SEATTLE LAND CQ'S 5 ACRE TRACTS ACCORnING To FLAT THEREOF F E ORDE.t IN '/QL. 6 OF PLATS Fa 9,0 R.EC F KING C 't1NTY, lASi°. LYING EAST OF COUNTy ROAD. .AREA 50,146 8.F.; 1. 4` ACRES 111 cri TiOc1 z Southcenter Community Baptist Church House 14742 Macadam Rd S. Tukwila, WA 98168 REVIEWED FOR CODE COMPLIANCE APPROVED OCT 29 2018 City of Tukwila BUILDING DIVISION MAY 21:20i0 RECEIVED CITY OF TUKWILA SEP 24 2018 PERMIT CENTER Drawing # SCBC P001 Site Plan Date 8/31/2018 36'834" 4' 7" 32' 1'/:" 6" 4' 1" 11' 1 1/2" 11'6" 5' 534" 4' 3:" Covered Patio m min Cr) 0 1 (.0 Kitchen 11'3"x19'6" 00 00 iia Dining Room 11'3" x 12'5" 2 1201 Bedroom 2 9'10"x11'10 Office/Study 9' 9" x 9' 4" 0 o o x m o Family Room 13'4"x18' 11.5" Bedroom 1 9'9"x14'7" C D E m m 7-1 1-4 m Typical 2x4, Siding Exterior Wall, Cedar Shaker Siding 7/16 Plywood Sheathing 2x4 Studs @ 16" O.C. Q,_/5' i att Insulation 6 L #30 Felt V.B 1/2" Drywall Taped & Sanded F 10'1031" 6'1134" 8' 3" 10'734" 36' 8 3:" Main Floor Plan Scale 1/4" = 1' Typical 2x4, Wall 1/2" Drywall Taped & Sanded 2x4 Studs @ 16" O.C. All replacement Windows Low E Glass with a U -Factor of .30 Alt Replacement windows will be sealed with Window and Door Sealing Tape as well as Caulking and foam insulation around gaps Door Schedule Window Schedule Main Floor Letter Width Height Type Material Existing or Replacement A 44 in. 37 in Sliding Wood Existing B 36 in. 24 in. Sliding Vinyl Replacement C 36 in. 48 in. Single Hung Vinyl Replacement D 36 in. 36 in. Sliding Vinyl Vinyl Existing Existing E 24 in. 48 in. Single Hung F 30 in. 48 in. Single Hung Vinyl Existing G 24 in. 48 in. Single Hung Vinyl Replacement H 36 in. 48 in. Single Hung Vinyl Replacement 1 24 in. 48 in. Single Hung Vinyl Replacement J 48 in. 48 in. Sliding Vinyl Replacement K 48 in. 48 in. Sliding Vinyl Replacement L 72 in. 36 in. Sliding Vinyl Replacement M 60 in. 36 in. Sliding Vinyl Replacement All replacement Windows Low E Glass with a U -Factor of .30 Alt Replacement windows will be sealed with Window and Door Sealing Tape as well as Caulking and foam insulation around gaps Door Schedule Vla m Floor Number Width Het • ht T ®±- Panel Thickness 1 36 in. 80 in. Sin le Exterior 1.5 in. 2 36 in. 80 in. Sin • le Exterior 1.5 in. 3 60 in. 80 in. Double Exterior 1.5 in. 4 32 in. 80 in. Sin • le Interior 1.5 in. 5 32 in. 80 in. Sin le Interior 1.5 in. 6 32 in. 80 in. Single Interior 1.5 in. 7 30 in, 80 in. Sin le lnterior 1.5 in. 8 24 in. 80 in. Pocket Interior 1.5 in. Coves Southcenter Community Baptist Church House 14742 Macadam Rd S. Tukwila, WA 98168 MO 2 1.260, REVIEWED FOR CODE COMPLIANCE APPROVED OCT 2 9 2018 City of Tukwila BUILDING DIVISION RECEIVED crr OF TUKWILA SEP 2 '¢ 2018 PERMIT CENTER Drawing # SCBC P002 Main Floor Date 8/31/2018 36'8W 3' 6" 6' 11" 5' 1" 16' 1h" 5' 1" Crawl space opening Furn ace (h----� I B 12' 10" 18' 5' 8'34" 36' 834" Basement Floor Plan Scale 1/4" = 1' Typical 6" Thick Concrete Basement Wall Typical 2x4, Wall 1/2" Drywall Taped & Sanded 2x4 Studs @ 16" O.C. Window schedule Basement Floor Letter Width Height Type Swing Material Wood Existing or Replacement Existing Existing A 30 in. 16 in. B 30 in. 16 in. Sliding Metal C 30 in. 16 in. Sliding Metal Existing D 30 in. 16 in. Sliding Metal Existing Number 1 2 Width 36 in. 30 in. tiKf 1:21310 Height 80 in. 80 in. Type Single Sliding Single Interior No Changes to Basement Panel Thickness 1.5 in. 1.5 in. Southcenter Community Baptist Church House 14742 Macadam Rd S. Tukwila, WA 98168 MAY 280 REVIEWED FOR CODE COMPLIANCE APPROVED OCT 292018 City of Tukwila BUILDING DIVISION RECEIVED cm' OF TUKWILA SEP 2 "1 2018 . ERMIT CENTER Drawing # SCBC P003 Basement Floor Date 8/31/2018 South Elevation Scale %" =1 foot Asphalt Shingles North Elevation Scale %" =1 foot Asphalt Shingles East Elevation Scale %" =1 foot °r 2120i13, Asphalt Shingles West Elevation Scale %" =1 foot Southcenter Community Baptist Church House 14742 Macadam Rd S. Tukwila, WA 98168 MAY 2'c20;C REVIEWED FOR CODE COMPLIANCE APPROVED OCT 292018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILAA SEP 2 4 2018 PERMIT CENTER Drawing # SCBC P004 Elevation View Date 8/31/2018