Loading...
HomeMy WebLinkAboutPermit D18-0335 - EC ELECTRIC - STORAGE RACKSEC ELECTRIC 18296 ANDOVER PARK W D18-0335 ^7w"A``�� City of Tukwila Department of Community Development C+ 6300 Southcenter Boulevard, Suite #100 2 Tukwila, Washington 98188 1408 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov Parcel No: Address: DEVELOPMENT PERMIT 3523049018 18296 ANDOVER PARK W Project Name: EC ELECTRIC Permit Number: Issue Date: Permit Expires On: D18-0335 11/1/2018 4/30/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: LIT SSBP COMMON AREAS LLC 1717 MCKINNEY AVE #19 , DALLAS, WA, 75202 MATT PREVOST 500 SW 16 ST, RENTON, WA, 98057 MR RACKS LLC 500 SW 16TH ST, RENTON, WA, 98055 MRRACRL924BN EC ELECTRIC 18296 ANDOVER PKWY, TUKWILA, WA, 98188 Phone: (425) 207-0058 Phone: (425) 207-0058 Expiration Date: 1/17/2020 DESCRIPTION OF WORK: SUPPLY (22) BAYS AND INSTALL PALLET RACK PER SEISMIC CALCUALTIONS WITH SPECIAL ANCHOR INSPECTION INCLUDES. Project Valuation: $7,800.00 Type of Fire Protection: Type of Construction: Electrical Service Provided by: Sprinklers: YES Fire Alarm: Fees Collected: $453.45 Occupancy per IBC: Water District: Sewer District: Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: 11— I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and ree to the g conditions attached to this permit. t Signature: (M�t—C— Date: t 1 1 / (�48) Ir't�r� SLLC Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 8: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 9: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 10: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 12: Maintain fire extinguisher coverage throughout. 14: Clearance between ignition sources, such as light fixtures, heaters and flame -producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 15: Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one-hour fire proofing, (b) sidewall sprinkler at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 13-16.1.4) 16: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.3.1) 17: Flue spaces shall be provided in accordance with International Fire Code Table 3208.3. Required flue spaces shall be maintained. 13: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 18: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 19: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 4046 SI-EPDXY/EXP CONC f CITY OF TUKWILA Community Development Department Public Works Department Project No. Permit Center Building Permit No. 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov .1f) -a335- 10 -1 -( s Date Application Accepted: Date Application Expires: 10 -1 -( (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: / v a9 (o A3V03`)444IL" (A) LeL44z4( Tenant Name: PROPERTY OWNER Name: v+� -I J,- r-1 �,��cI4 AddresssOO 1 1 G_t_ City: neAAAi34-' State: J _ Zip:g605- ` Phone: (4Z5 -lid? -o6 6 t- Address: / 6 ? 1 O 1,4„41.3 Up� W Cit : 'IA_ State:co_ zip:cm CONTACT PERSON - person receiving all project communication Name: v+� -I J,- r-1 �,��cI4 AddresssOO 1 1 G_t_ City: neAAAi34-' State: J _ Zip:g605- ` Phone: (4Z5 -lid? -o6 6 Email: /44•041-r 04, , 1` (24,444___s.C-lv/" e GENERAL CONTRACTOR INFORMATION n 'n C4% r' �� Company Name: Ifrt -to L� Address:50o J (j / +10k. S.�- l' City: Yi ✓) State: _ l0 Zile O5 w [ ✓(�.� Phoneti ZS_. G 3-7_005-8 Contr Reg No.:M goce-ln ,2'�xa e: /iifz-oz_o Tukwila Business License No.: 13, i6 _o' 5&ts-- ( - H:\Applications\Forms-Applications On Line\2011 Applications'Permit Application Revised - 8-9-11.docx Revised: August 2011 bh 7. King Co Assessor's Tax No.: 8 /007_1 7_1 w z-0 Suite Number: Floo:( New Tenant: K Yes ❑ ..No ARCHITECT OF RECORD Company Name: ,J / 4 Architect Name: Engineer Name: 25vere 1 L.,v...444, v' � IA . 5 Address: Address:21( Z2, �r I' , ' # City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Company Name: - Q L �� -rotIA_ _c_. --KA Engineer Name: 25vere 1 L.,v...444, v' � IA . 5 L. Address:21( Z2, �r I' , ' # City: �/ Sttatte l �__ Zip -� (�� Phone: Z0/ 67_7363 p f' Email: rj A..._ LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: / e �� /er, Avoiyai City CGS f 14r Stater Page 1 of 4 BUILDING PERMIT INFORMATION -14106-431-3670 00 Valuation of Project (contractor's bid price): $ 7, SDO Existing Building Valuation: $ Describe the scope of work (please provide detailed information): S0Pe' 3 S -p S `1 � I Ir�4�c�^/ci k uvi C- f e.✓t� sustA c ,C ( S w ; �t A &i/tA011 .titiSpee)4-10 MAAG 4-4 Will there be new rack storage? Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: XSprinklers D Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety ata Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\ApplicationsWorns-Applications On Line\2011 Applications\Pernit Application Revised - 8-9-11.docx Revised August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC Floor Ls 145 7fop0 100 - ��, 2nnd Floor 3rd Floor Floors thru Basement Accessory Structure*. Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: XSprinklers D Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety ata Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\ApplicationsWorns-Applications On Line\2011 Applications\Pernit Application Revised - 8-9-11.docx Revised August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES – Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN 12flIORIZE AGENT: Signature: Y✓l (/2`le-otEj U__C_ Date: 11 9/ 1 6 Print Name: IM- P ),3s\-- rM (Li i1'rr(' I (443ay Telephone: 2_a, —6c) —7`( z_q( Mailing Address: 3 O 0 5 3 ( to 't 3*— eP- ,6,J (,ci J , q 3057 City H: Applications'Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11 docx Revised: August 2011 bh State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $453.45 D18-0335 Address: 18296 ANDOVER PARK W Apn: 3523049018 $453.45 DEVELOPMENT $440.85 PERMIT FEE R000.322.100.00.00 0.00 $252.03 PLAN CHECK FEE R000.345.830.00.00 0.00 $163.82 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $25.00 TECHNOLOGY FEE $12.60 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R15665 R000.322.900.04.00 0.00 $12.60 $453.45 Date Paid: Friday, October 19, 2018 Paid By: MR RACKS Pay Method: CHECK 8425 Printed: Friday, October 19, 2018 9:28 AM 1 of 1 YSTEMS DIS--03Z5- 6300 Ig=0.335 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION C (206) 431-36 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 Project: En G C-- ''L'CC/ iG Typee of Insp ction: teCt /;N,4 -L Address: 18 Z94 ,q/ - t-ic rJ P, Date Called: Special Instructions: J lC,`�/Ds Date Wanted: zy -zi--2Z a.m. p.m. Requester: Phone No: pproved per applicable codes. El Corrections required prior to approval. COMM TS: G(li4- InsPectorjZ2 AVA 1172/),-Ai-ci Date:s7z' ` 247 1-1 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit Di - c PERMIT NUMBERS CITY OF TUKWILA FIRE' DEPARTMENT 206-575-4407 Project: Z -Y)0. -C-) (IOC Type of Inspection: / - 44,,,.., Address: Suite #:� �'�/�j Contact Person: / Special Instructions: r 14100 rf- Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS:n—FA /7..-, i' ir--S /,$,,L-? %/ lef,e;dei 504 Sprinklers: Fire Alarm: /Iej (vil'i .q us/- /74=a-7- / hi." ,4ye i' t a i-` r 14100 rf- Occupancy Type: ?A 6-9re sc /7 iL -Ss 1 -- Al( (o r r e r l ° c -i-, 5 ,rt l' e GF,/4 _ Add 0 &t7 .77-e 5 C '1l (' 1 z"c,c) Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: 'fr5 --7/ Date: /2/c/ /t Hrs.: G� $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:! CC %2e- Cye-AZ'g- Type of'spection: Address: Suite #: /6 2 96 ieW) Contact Person: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: ----- �� i /V / //v r Occupancy Type: roti ,. g5 ropA1-7772 i 7` ...5., Lz s 01 /N .5744.1. — (1/-i( (7L . Goo /0 A, k -1414 (z/ -97z /vice (Za 6) 7/.3 - /6 S s- Arc,, ii,,,z Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: . ,1;tel 3 Date: /// / Hrs.: / 0 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip:: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Job Title EC Cir-cr/2/C—17#k1/441MA By enL Date 10— 2oI? Job No./4 3 Subject /2001—F°49/6, 5 -76 -Et cu .& 07-1) piAck.s Checked Sheet / of 3 4)ALq3l: i besfaa op Ow comirdevysi 7D 7I 2015 ZZDq, 'lift: WIZ temx C,t?tk SEC. /5.5,3 op Act 7 -it) tisido4 we , D 1 e7M D ; kisr v. bi trr rt' , Z, via) FActuri is r )r Oft to TD ri post. o, ci C2/3}6 xSJVA Sr 1.42 . T & ilf)DitErts E 7Wtt.ny qr.= LD FA. 5tra cLecs V. g Iko I4S dF 0314 1464)) 0, i sai Gc}s , g = to.o Lc cr, (Mme* 2)1,, V ws w 00.07. P4. P 4 V 4- , 2 k» tam 1.7 pax. r2 4C&. Lo AV peg peg Le pez- AEtz eAktts SWC C4) gates �9Ei 4 i ' cwt VIEWED FOR CODE COMPLIANC APPROVED OCT 31 2018 V,46- Lot) ILEAxtE FR 044 D64° WTukwila Pg6 USE 1. C t Al Stint >gat:L1NG DIVISIO 111./.05V, 4crts -Trfpe A (swim Los= 1z/ }-fit = ;(1ttaellevet a. f Sgt * 3 2.104 = m.ggG t e 21. )4 13Q.%4`r :.**v.:5 . oa 5Pt g 2.1060 k 1sidc, , : Zo 4 T 44IN aAfrilf2 c 64.--.r4-4k)x 3.15 t. zt V - 4177410{, Limp dA) 7PP Levet or.)LH 0. 4.1ot? I " T / 37 s 4 \/ 34-3 4tfrot 44k z , ce np . ,75 (2,504,4- 4.s0)+P,15 = 5.701 2- +ick,, 4- /4 s t m tso i,) se -1 Oen Ark caq•S C 1/2, C- ) peg- 00156 FATE tin r 33bt) 4 peg. - es emit -3o3-7 tot' spec/AL s p 7' t &i 4 tin , 3Y4, h 341 h4.=s try t �et OLI/JC9 0 0 1, 4 CV/411n . xjty ` 7:.1 s 242 i V. .0 t1 141°1 , Iil cktiUtt 4. t414W4 a 0 -So - - O.i7 as 6.4'7 —,0 4!. zo 6440/440 e #444. VI -11. 0,7% 4 IDiA6..4mee _sCC S) +C om. =- DiAtd 61.4CE P 1.34-4=',' P.'7 P , 1.61k t41I.p near RECEVVED CITY OF TUKWIL OCT 1 9 2018 PERMIT CENTER Job Tdke Sub act By'7R Date /0- 201g Job No. Ik4 3 Checked Sheet w fAta. 614461 f4 1 /2 o I 10K !'L- - ier/o/us ; 4e r , 2& L rz , 40s1;0 *Av.. (kilt-) t- i1.4D. = 1e O) fig 7 7,z54' 'I ra lz A e4fk s 2.o2 - groi 7 D.75 - OA G PLAt 546 etc ,,u, tc' .: 5.70 k gh-s pc,41: is ist24 5 ;. n ~ 4p 4o .14-2 -q2 r P.11.3 — e Asti. = .7K . f .Ira (cam /3 pt.r m = 19,111,5.(2,5-f/2 8.447 kV" 642, is 5i 27 .*i /20/1.0. z: = t9.3i s" — Q < krunt. s= 3% `r 7»t16dc C JCI 54 »ri,sef- 2,rb0 fig". L) s7.4436 hto / 7 x 6Q.sa /fz = 0.531 t =1.41 p, 31 rt. p (4)4%2 L116, ' ,4 txop /. sd s = Job Title By 1 •fit Date 10— ►1 ' Job No. it 3 Checked Sheet 3 o€ 3 C-49/..tbstikii I AO 3494 C-S�cirl1Ps to)ni 344 « 711M Ate .132 :..q39 T& 1.74:$04 rort 31/484 cos ?AID 14c.4 At SSS! "`y t4 .5$1 k3 rl t.1 5'rc .V00 sr.. 0,014 14.4P 4g1.5 =41" Fa 2 i a (4 s) n�. i "fi :. 4,01 1.41 m t.22 g 47.11 4-riot♦♦110.2 .4 pt 7 3d 14 S. s y 0..37 '' 6.3r % x.12- —at < 1.0 4/61= 0.44 .- GPS /.Q 5/2/2019 City of Tukwila Department of Community Development MATT PREVOST 500 SW 16 ST RENTON, WA 98057 RE: Permit No. D18-0335 EC ELECTRIC 18296 ANDOVER PKWY Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 6/4/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 6/4/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Kandace Nichols Permit Technician File No: D18-0335 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Field Report Report #: 77014 A.A.R. Testing Laboratory, Inc. 7126 180th Ave.N.E., Park 180, Suite C101, Redmond, WA 98052 _Phone 425.881.5812 Fax 425.881.5441 Client: Mr. Racks 500 S.W. 16th St. Renton, WA 98057 Contact: Carey Ferguson/Matt Prevost Project Number: 18-818 Permit #: D18 0335 Project Name: EC Electric Address: 18296 Andover Park W. City: Tukwila Inspection Performed: Proprietary Anchors Date: 11/7/2018 Time: Temperature: Anchor bolts for pallet racks total 22 bays. Verified installation of Simpson SB2 anchors 1/2" by 4 3/4" with 3 1/2" embed, torqued to 60 ft./lbs. All installed per ESR 3037 and per plan. RECEIVED CITY OF TUKWILA NOV 13 2018 PERMIT CENTER Distribution: Distribute Client ❑ Distribute Contractor ❑ Distribute Engineer ❑ Distribute Owner • Distribute Municipality ❑ Distribute Other ❑ Distribute Architect ❑ Distribute Other Inspector: Trow, Michael Reviewed by: Gebhardt, Diane All reports are considered confidential and are the property of the client and A.A.R. Testing Laboratory, Inc. Reproduction except in full without the written consent of A.A.R. Testing is strictly forbidden COCA CON PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0335 DATE: 10/19/18 PROJECT NAME: EC ELECTRIC SITE ADDRESS: 18296 ANDOVER PKWY X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: 1)V -J AV01? 146 Building Division Public Works M 1O N€ Fire Prevention Planning Division Structural nPermit Coordinator n PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 10/23/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required nApproved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 11/20/18 n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW D Staff Initials: 12/18/2013 MR RACKS LLC Washington State Department of Labor & industries Home Espanol Contact Safety & Health Claims & Insurance cJ Page 1 of 2 A-% Index I felp My L.&l Workplace Rights Trades & Licensing MR RACKS LLC Owner or tradesperson Principals Ferguson, Carey Scott, PARTNER/MEMBER Ferguson, Julie Lynn, PARTNER/MEMBER Ferguson, Carey Scott, AGENT GONSER, BRETT, PARTNER/MEMBER (End: 04/30/2013) MCLENDON, ROBERT, PARTNER/MEMBER (End: 04/30/2013) Doing business as MR RACKS LLC WA UBI No. 602 779 014 500 SW 16TH ST RENTON, WA 98057 425-207-0058 KING County Business type Limited Liability Company Governing persons CAREY FERGUSON JULIE FERGUSON; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. MRRACRL924BN Effective — expiration 01/03/2008— 01/17/2020 Bond AMERICAN CONTRACTORS INDEM CO Bond account no. 100031015 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 01/03/2008 12/20/2007 Expiration date Until Canceled Insurance Ohio Security Ins Co $1,000,000.00 Policy no. BKS 54574031 Received by L&I Effective date 05/06/2018 06/29/2017 Expiration date Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602779014&LIC=MRRACRL924BN&SAW= 11/1/2018 King County 0010 �t,►it►'f The Information Included on this map has been complied by King County staff from a variety of sources and Is subject to change without notice. King County mattes no representat ions or warrant les, express or Implied, as to accuracy, completeness, llmeliness, or rights to the use of such information. Thls document Is not Intended for use as a survey product. King County shall not be liable for any general, special, Indirect , Incldental, or consequential damages including, but not limited to, lost revenues or lost profits resulting from the use or misuse of the information contained on this map. Any sale of this map or information on this map Is prohibited except by written permission of King County. Date: 10/19/2018 NOTES: 1. ALL PALLET RACK POSITIONED TO LEAVE A 6" FLUE SPACE MINIMUM ON ALL SIDES WHEN LOADED. 2. SHELF SUPPORTS ARE WIRE DECK - NO SOLID SHELVES 3. WAREHOUSE AREA IS APPROXIMATELY 000 SQ. FT. SEPARATE PERMIT 1 r :QUI^ED FOR: LtYP ^cchanical L��," -lcctrical P �I, jiumbing E Cas P pkig Gay of Tukwila LD'ItIG DIVISION Analysis and Design of Racks Conform to the 2015 IBC SEC 2209. The 2012 RMI Code and Section 15.5.3 of ASCE 7-10 Using the ASD Method: V=.67-C.s-I.p-Ws. Ip=1.0 Facility is not open to the public. King County Tax Parcel Number 8700210020 legal Description: TUKWILA BSIP 1,17 REVISIONS No changes shall be rnade to the scope of work without prior approval of T'l olvila Building Division Revis:cns will require a new plan submittal and may include additional plan review fees. 0011 Scope of Work: Supply and Install (22) Bays of Pallet Rack. Special inspection of wedge anchors included. FILE COPY Permit No. .'19.)*-- 0 333— Plan review approval is subject to errors and omissions. A^proval of construction documents does not authorize the violation cf any adopted code or ordinance. Receipt of approved Field Cop and co ditions is acknowledged: By: Date: City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED OCT 31. 2018 City of Tukwila kwila BUILDING DIVISION j9;o35s RECEIVED CITY OF TUKWILA OCT 19 2018 PERMIT CENTER b b •- o aa O 03 F41. CLCIN a W �,s eisJrWrw u oE • H O CJ cz CAI 114 U DRAIN BY: MTP SCALE: 3/16" = DATE 10-19-2018 DRAWING NO: CHECKED BY: SHEET NO. 1 OF 1 SHEETS NOTES: 1. ALL PALLET RACK POSITIONED TO LEAVE A 6" FLUE SPACE MINIMUM ON ALL SIDES WHEN LOADED. 2. SHELF SUPPORTS ARE WIRE DECK - NO SOLID SHELVES 3. WAREHOUSE AREA IS APPROXIMATELY 7,000 SQ. FT. LIGHTE EXIT . IGN WIT EEGENC LIGHTS 119'-t" 48" X 144' REVIEWED FOR CODE COMPLIANCE APPROVED OCT 31 2018 DRAWN BY: MTP SCALE: 1 /8" = 1'-0" DATE 10-15-2018 DRAWING NO: CHBCKCD BY: RECEIVED CITY OF TUKWILA OCT 1 9 2018 PERMIT CENTER LEXIT TE EXIT IN ITi i EME NOTES: 1. ALL PALLET RACK POSITIONED TO LEAVE A 6" FLUE SPACE MINIMUM ON ALL SIDES WHEN LOADED. 2. SHELF SUPPORTS ARE WIRE DECK - NO SOLID SHELVES 3. WAREHOUSE AREA IS APPROXIMATELY 7,000 SQ. FT. GE `: CY FLO*tLIGI i TS LIGHTING IT EMERGENCY BJATTERY IACKUPEMERGENCY B 00 16'-9" OFFICE AND BATHROOMS 119'-2" .11:348" X 144" 15'-6" 15'-6" roc) 14'-62" in 00 4= 6.0 102'-5" REVIEVI CODE CO APPR OCT 3 IED FOR NPLIANCE OVED 1 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 192016 -aERIVIll CENTER fht 03 b C© omiR c°4 0 .Q0E 9100 hogogOM gqgPyVA Ohgd IIR co it, 4 c4 z , U 5' ,... c. c., E...4 4 )`-'d ...N DI 14, cv ...., 4 zr_ 4., N. ON w DI -4 W Q g 0 w �c, ) k• O o�� U E" 4ip coo � Z' U o L. tam 0. CD co I— CD co .�+y+ ' 0) o H •V caw 41) CO _ La 01 CJS �U wF-- DRAWN BY: MTP SCALE: 1/8" = —0» DATE 10-15-2018 DRAWING NO: CHECKED BY: SHEEP NO. 1 OF 1 SOF UPRIGHT COLUMN 12' � 4' -{ SIDE DETAIL ALL RACK TYPES RACK ELEVATIONS SCALE: 1/2" = 1' MIN. 1" (TYP.) //v BRACING CONNECTION DETAIL ALL RACK TYPES DIAGONAL BRACE (TYP.) 1/8" HORIZINTAL BRACE TYP.) RACK DETAILS SCALE: 3" = 1' 375 RCi 3" c0 c0(0 C CD 2" TYP. AS NOTED 1/4" REF. ❑ ❑ ❑ ilot ❑ .531 SQUARE 1 i 12' TOP OF STORED NOT TO EXCEED 16'0' TALL FRONT ALL RACK TYPES 1/8" 14GA THK. 7/8" -T 3" -R1/8" TYP. COLUMN DETAIL ALL RACK TYPES 1 1/2" -h --L1 14 GA 14 GA 1 1/4" COLUMN STRUT 3/8" or 10 Ga. THK 4-3/4" T 2 1/2" 5" 2 1/2" 1 -2 1/2"4 1" (TYP) El% STRUCTURAL NOTES: 1. RACKS ARE MANUFACTURED BY SPACERAK OF LODI, CA OR EQUAL 2. MINIMUM YIELD (Fy) AND ULTIMATE (Fu) STEEL STRENGTHS FOR SELECTIVE RACKS SHALL BE AS FOLLOWS: (a) BEAMS AND COLUMNS Fy=50ksi Fu=65ksi. (b) BRACING STRUTS Fy=36ksi Fu=58ksi. (c) BASE PLATES FY=36ksi Fu=58ksi. 3. TYPE "A" RACK MAXIMUM RACK LOAD PER LEVEL PER PAIR OF BEAMS SHALL BE 3,000 LBS TYPE "B" RACK MAXIMUM RACK LOAD PER LEVEL PER PAIR OF BEAMS SHALL BE 1,800 LBS 4. CONCRETE SLAB IS GIVEN AS 5 1/2" THICK WITH fc'=2,500 psi. 5. ALLOWABLE SOIL BEARING PRESSURE IS GIVEN AS 1,500 psf FOR GRAVITY LOADS. 6. 'I'lE-DOWN ANCHORS SHALL BE SIMPSON STRONG BOLT II WEDGE ANCHORS. TYPE "A" USE TWO (2) 1/2"0 X 4-3/4" ANCHORS WITH A 3 2" EMBEDMENT PER BASEPLATE. TYPE "B" USE ONE (1) 1/2"0 X 4-3/4" ANCHORS WITH A 3 2" EMBEDMENT PER BASEPLATE. PERIODIC SPECIAL INSPECTION IS REQUIRED AND SHALL BE COMPLETED PER ICC ESR -3037. 7. POST LOAD SIGNS NOT LESS THAN 50 SQUARE INCHES IN AREA SPECIFYING THE DESIGN CAPACITY AT CONSPICUOUS LOCATIONS. 8. IF ANY DISCREPANCY OCCURS, CONTACT THE ENGINEER FOR CLARIFICATION. 9. ANALYSIS AND DESIGN OF RACK CONFORMS TO THE 2015 IBC SEC 2209, THE 2012 RMI CODE, AND SEC. 15.5.3 OF SEI/ASCE 7-10 USING THE ASD METHOD WHERE: V = 0.67 Cs Ip Ws AND Ip= 1.0 (RESTRICTED AREA - NO PUBLIC ALLOWED) 1.423 Cs = 2.5 Ca /R AND Ca = 0.3795 FOR THE GIVEN ADDRESS AND SITE CLASS D S1 0.531 R = 4.0 TRANSVERSE (BRACED) DIR. R = 6.0 LONGITUDINAL (MOMENT) DIR. Fa= 1.0 10. PROJECT HAS NO FIELD WELDING, ALL WELDING IS COMPLETED IN THE SHOP BY LICENSED WELDERS 11. THERE ARE NO SHOP DRAWINGS FOR THIS PROJECT. THIS DRAWING SHALL SERVE AS THE PROJECT SHOP DRAWINGS. FIRE PROTECTION NOTES: 1. DESIGN DENSITY OF SPRINKLER SYSTEM: .39 GPM OVER 5,600 SQUARE FEET (per WSRB 46-3348 Report ) 2. TEMPERATURE RATING OF SPRINKLER HEADS: 160° F. (per WSRB 46-3348 Report ) 3. TYPE OF PRODUCT: ELECTRICAL SUPPLIES. METAL COUPLERS, FITTINGS, OUTLET BOXES, RECEPTACLES, SWITCHES. METAL LIGHT FIXTURES. PVC CONNECTORS, ELBOWS AND BOXES. ON STANDARD WOOD PALLETS. NON ENCAPSULATED. SPOOL WIRE STORED SEPARATELY NOT TO EXCEED 5' HIGH. PVC CONDUIT STORED OUTSIDE. 4. TOP OF STORED PRODUCT NOT TO EXCEED : 16' 0" 5. APPROXIMATE CEILING HEIGHT: 28'11" .... 26'5" TO TRUSSES EXITING NOTES: 1. EXTERIOR DOORS ARE 3' SWING TYPE WITH LOCKING KNOB WHICH REQUIRES NO SPECIAL KNOWLEDGE OR EFFORT TO OPEN. 2. EXTERIOR EXIT DOORS TO BE MARKED PER APPLICABLE CODE 3/16" V 5/8" 0 HOLE (TYP) 3/8" THICK 3/16" BASE PLATE DETAII, TYPE "A" FLOOR ANCHOR DETAIL SEE NOTES FOR SPECS 5/8" DIA. 2 HOLES 1I BRACKET ASSY. AS NOTED 0 TYP.,1/8'1 BEAM SECTION 16 GA TI -K. ,...&1/2 -8 ASTM A572 GR50 BEAM DETAIL ALL RACK TYPES BASE PLATE DETAIL TYPE "B" 2 3/4" /8 18" 5" 1/8" V REVIEWED FOR CODE COMPLIANCE APPROVED 0C1312018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWII.,A i OCT 1 9 2018 V.63 5 3ER1011 C,I.:,4l'Ej-'s w tt om a411044 $1/L00 opitzgc48L iHHih o OCH co 0 Z C:3 eN1 c%2 02 to CA Erb W "44ej z . r� �w a L.� 0 U 500 SW khl A A ��J gl!" 0 : 1; C31- .mow IT. La 00 = 8 C) <X DRAWN BY: MTP SCALA': AS SHOWN DATE 10-15-2018 DRAWING NO: CHECKED BY: SHEET NO. 2 OF 3 SHEETS