Loading...
HomeMy WebLinkAboutPermit D18-0364 - TH NAIL BAR & SPA - WAXING STATIONSTH NAIL BAR & SPA 17250 SOUTHCENTER PKWY 140 018-0364 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 290E Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov Parcel No: Address: 7888920020 DEVELOPMENT PERMIT 17250 SOUTHCENTER PKWY Unit140 Project Name: TH NAIL BAR & SPA Permit Number: D18-0364 Issue Date: 3/26/2019 Permit Expires On: 12/30/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: WIG PROPERTIES LLC -SS 4811 134TH PL SE , BELLEVUE, WA, 98006 DANNY CHAU 5028 HIGHLAND DR SE , AUBURN, WA, 98092 Phone: (206) 304-2928 CHAU CONSTRUCTION LLC Phone: 5028 HIGHLAND DR SE , AUBURN, WA, 98092 CHAUCCL844JF Expiration Date: 4/10/2020 Lender: Name: WIG PROPERTIES LLC -SS Address: 4811 134TH PL SE , BELLEVUE, WA, 98006 DESCRIPTION OF WORK: SCOPE OF WORK INCLUDES ADDITION OF NEW WALLS AND DOORS AS SHOWN TO PROVIDE FOR (2) PRIVATE WAXING STATIONS SEPARATION OF AREAS. ALL EXITS AND RESTROOMS ARE EXISTING WITHIN THE SUITE AREA. THE OWNER PROVIDED THE DEMISING WALL, NEW DOUBLE STOREFRONT ENTRY DOORS, WATER HEATER AND ELECTRICAL PANEL RELOCATION UNDER SEPARATE PERMIT. Project Valuation: $45,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $1,666.84 Occupancy per IBC: B Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: / International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load:. Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signat Volumes: Cut: 0 Fill: 0 Number: 0 Date: 7—/..) I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: 7--( z -- This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 5: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterally braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. D 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 13: Signs are not approved as part of this permit. A separate sign permit is required 17: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 14: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 15: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 16: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 18: Maintain fire extinguisher coverage throughout. 19: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1010.1.9) 20: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 21: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 22: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1010.1.9.1) 26: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 23: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 24: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 27: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2437. 29: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 28: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 30: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 31: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.11 of the International Building Code. 32: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. 25: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 33: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 34: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 35: The special inspections for steel elements of buildings and structures shall be required. All welding shall be done by a Washington Association of Building Official Certified welder. 36: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 37: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 5190 BACKFLOW - WATER 5190 BACKFLOW - WATER 1700 BUILDING FINAL** 1700 BUILDING FINAL** 0301 CONCRETE SLAB 0301 CONCRETE SLAB 0301 CONCRETE SLAB 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING 0502 LATH/GYPSUM BOARD c 0406 SUSPENDED CEILING Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 7888920020 Permit Number: 17250 SOUTHCENTER PKWY Unit140 Issue Date: Permit Expires On: Project Name: TH NAIL BAR & SPA D18-0364 3/26/2019 9/22/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: WIG PROPERTIES LLC -SS 4811 134TH PL SE , BELLEVUE, WA, 98006 TOMMY NGUYEN 11856 9TH AVE SW , SEATTLE, WA, 98146 JOHN HUNT CONSTRUCTION LLC 3114 NE 82 ST , SEATTLE, WA, 98115 JOHNHHC920Q4 Lender: Name: WIG PROPERTIES LLC -SS Address: 4811 134TH PL SE , BELLEVUE, WA, 98006 Phone: (206) 427-0101 Phone: (206) 226-7122 Expiration Date: 3/27/2019 DESCRIPTION OF WORK: SCOPE OF WORK INCLUDES ADDITION OF NEW WALLS AND DOORS AS SHOWN TO PROVIDE FOR (2) PRIVATE WAXING STATIONS SEPARATION OF AREAS. ALL EXITS AND RESTROOMS ARE EXISTING WITHIN THE SUITE AREA. THE OWNER PROVIDED THE DEMISING WALL, NEW DOUBLE STOREFRONT ENTRY DOORS, WATER HEATER AND ELECTRICAL PANEL RELOCATION UNDER SEPARATE PERMIT. Project Valuation: $45,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $1,666.84 Occupancy per IBC: B Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: 'T I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: UkLuti imy . V6- 7e Date: 03/Z6/R This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 5: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterally braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 13: Signs are not approved as part of this permit. A separate sign permit is required 17: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B;C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 14: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 15: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 16: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 18: Maintain fire extinguisher coverage throughout. 19: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1010.1.9) 20: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 21: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 22: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1010.1.9.1) 26: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 23: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 24: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 27: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2437. 29: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 28: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 30: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 31: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.11 of the International Building Code. 32: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. 25: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 33: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 34: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 35: The special inspections for steel elements of buildings and structures shall be required. All welding shall be done by a Washington Association of Building Official Certified welder. 36: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 37: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING 4037 SI -CAST -IN-PLACE 4027 SI -COLD -FORM WELD 4046 SI-EPDXY/EXP CONC 4039 SI -SEISMIC RESTIST 4035 SI -SOILS 4004 SI -WELDING 0406 SUSPENDED CEILING CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. 1)1 8- 03 (Q -) Project No. Date Application Accepted: Date Application Expires: f)-IN-I� S'I�t- 9 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 17250 South Center Parkway King Co Assessor's Tax No.: 7888920020 Suite Number: 140 Floor: 1 Tenant Name: NU Spa and Nail Salon PROPERTY OWNER Name: WIG Properties LLC -(David Krueger-conta Address: 4811 134th Place SE City: Bellevue State: WA Zip: 98006 CONTACT PERSON — person receiving all project communication Name: Vicki Somppi Address: 3025 112th Ave NE Suite 110 City: Bellevue State: WA Zip: 98004 Phone: (206) 310-0827 Fax: Email: vickis@workplacearchitecture.com GENERAL CONTRACTOR INFORMATION Company Name: TBD Company Name: Workplace Architecture Company Name: N/A Architect Name: Eric Drivdahl Address: Address: 3025 112th Ave NE Suite 110 City: City: Bellevue State: WA City: State: Zip: Phone: Fax: Phone: Fax: Contr Reg No.: Email: Exp Date: Tukwila Business License No.: H:\Applications\Fonas-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh New Tenant: 0 Yes ❑..No ARCHITECT OF RECORD Name: N/A Company Name: Workplace Architecture Company Name: N/A Architect Name: Eric Drivdahl Address: 3025 112th Ave NE Suite 110 City: City: Bellevue State: WA Zip: 98004 Phone: (206) 310-0827 Fax: Email: eric@ghdarch.com State: ENGINEER OF RECORD Name: N/A V vv -K r As 4 "` Company Name: N/A Address: Engineer Name: City: State: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: N/A V vv -K r As 4 "` Address: City: State: Zip: Page 1 of 4 e BUILDING PERMIT INFORMATION - 206-431-3670 Valuation of Project (contractor's bid price): $ 7l 6-0 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): SCOPE OF WORK INCLUDES ADDITION OF NEW WALLS AND DOORS AS SHOWN TO PROVIDE FOR (2) PRIVATE WAXING STATIONS SEPARATION OF AREAS. ALL EXITS AND RESTROOMS ARE EXISTING WITHIN THE SUITE AREA. THE OWNER PROVIDED THE DEMISING WALL, NEW DOUBLE STOREFRONT ENTRY DOORS, WATER HEATER AND ELECTRICAL PANEL RELOCATION UNDER A SEPARATE PERMIT. Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): 516,516 Floor area of principal dwelling: 229,968 Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 924 Compact: Handicap: Will there be a change in use? 0 Yes No If "yes,,, explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers 0 Automatic Fire Alarm ❑ . None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes El No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line 12011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1'`Ftoor 2,054 0 0 type III B 2" Floor 3'd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): 516,516 Floor area of principal dwelling: 229,968 Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 924 Compact: Handicap: Will there be a change in use? 0 Yes No If "yes,,, explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers 0 Automatic Fire Alarm ❑ . None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes El No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line 12011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFORMATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ...Tukwila ❑... Water District #125 0 ...Water Availability Provided Sewer District 0 ...Tukwila 0 ...Sewer Use Certificate ❑ .. Highline ❑ ... Valley View ❑ .. Renton ❑ ... Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) 0 .. Geotechnical Report ❑...Traffic Impact Analysis ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s) 0 ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way 0 ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ ...Sanitary Side Sewer 0 .. Abandon Septic Tank 0 .. Grease Interceptor ❑ ...Cap or Remove Utilities ❑ .. Curb Cut 0 .. Channelization ❑ ...Frontage Improvements ❑ .. Pavement Cut 0 .. Trench Excavation ❑ ...Traffic Control ❑ .. Looped Fire Line 0 .. Utility Undergrounding 0 ...Backflow Prevention - Fire Protection " Irrigation Domestic Water ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size .. WO # ❑ ...Water Only Meter Size WO # ❑ ...Sewer Main Extension Public 0 Private 0 ❑ ...Water Main Extension Public 0 Private 0 0 ...Deduct Water Meter Size FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water 0 ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: 11/01/2018 Print Name: Vicki Somppi Day Telephone: (206) 310-0827 Mailing Address: 3025 112th Ave NE Suite 110 Bellevue WA 98004 City State Zip H:1Applications\Fmms-Applications On Line 12011 Applications\Pe mit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 4 of 4 Cash Register Receipt City of Tukwila Receipt Number R17253 DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $1,065.84 D18-0364 Address: 17250 SOUTHCENTER PKWY Unit140 Apn: 7888920020 $1,065.84 DEVELOPMENT $1,019.61 ADDITIONAL PLAN REVIEW R000.345.830.00.00 1.00 $70.00 PERMIT FEE R000.322.100.00.00 0.00 $924.61 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $25.00 TECHNOLOGY FEE $46.23 TECHNOLOGY FEE R000.322.900.04.00 0.00 TOTAL FEES PAID BY RECEIPT: R17253 $46.23 $1,065.84 Date Paid: Tuesday, March 26, 2019 Paid By: TOMMY NGUYEN Pay Method: CHECK 1036 Printed: Tuesday, March 26, 2019 3:41 PM 1 of 1 SYSTEMS Receipt Number DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $601.00'' D18-0364 Address: 17250 SOUTHCENTER PKWY 144 Apn: 7888920020 $601.00 DEVELOPMENT $601.00 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R15843 R000.345.830.00.00 0.00 $601.00 $601.00 Date Paid: Wednesday, November 14, 2018 Paid By: TH NAIL BAR & SPA CORP Pay Method: CHECK 1002 Printed: Wednesday, November 14, 2018 2:34 PM 1 of 1 SYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 3 0 Permit Inspection Request Line (206) 438-9350 PERMIT NO. Proje�ct: ` T Mr t94Pk4L, G/L Type of Inspection: bat 40.46 -6.44c_ Address: - / , ' l i LSV 4,ini IQiom/ Date Called: Specia nstructions:Date n �� I� Wanted: a.m. Requester: ak-( Phone No: G oL4 Vtz e) pproved per applicable codes. Corrections required prior to approval. OMMENTS: Inspector: Date: REINS ION FE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD 11, Retain a copy with permit I (1,.)v7 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pr_ oKti: �� �� ' ``m Pitt Ty/pe of Inspec e: &Awl Star/ Address: 4644leL 17ZS0 Sat, / y / Special Instructions: , `DO P /,',‘O ` to Wanted: (n- 6- z)o'/ a,m. p.m. Reque . ice. /. Phone No: 206 ' 2 — ®/o / Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 41,41(46,,e' Inspector: Ki2i(x---4,2_) Dater `6, 00)Q REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Dis 03 Project:\�}�,{ '. i ./A}�t.cw- Type of In�spe'ction: Address: to-.? Z Pk/ Date Called: Special Instructions: 'fit ta ate Wanted: 6-- 26-1q ,, •.. Requester: ---- Phone No: Approved per applicable codes. Corrections required prior to approval. OMMENTS: Inspector: Date: REINSPECTION FE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Dte) 0364 Project: Type of Inspection: Address: 17Zso WI Pig Date Called: Special Instructions: 1 /40 D e Wanted: 4—S"' %9 a.m. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: (v.< ckPofie'C} tt 114 Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit biS 0 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project:Type Oki-- of Inspection: Address: /7tS 7 etAiev. P, Date Called: Sp tial Instructions: ' ` Dat Wanted: 41_14-19' qietAuli p.m. Requester: Phone No: pproved per applicable codes. /COMMENTS: EJCorrections required prior to approval. Cer'A:e" (1471/'vreiz°C9-- Ins pector:',r Date: Lif _ �Z�l REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Cal! to schedule reinspection. Interior Lighting - Space -By -Space Meth 2015 Washington State Energy Code Compliance Forms for Commercial Buildings inclu LTG -INT -SPACE _ _.._ _..... Project Title: NU Spa and Nail Salon Date 11/1/2018 Calculation Area NOTE 9 Q Q Addition - Q Addition stand alone + existing Q Spaces where < 50% of O Spaces where a 50% of Q luminaires are replaced luminaires are replaced For Building Department Use FY;:,: . l LPA Calculation Type Q Standard Q Additional Efficiency Package Option 0 C406.3 Reduced Interior Lighting Power To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA. Refer to C406.3 for additional requirements. Maximum Allowed Lighting Wattage ""E1 Location (plan #, room #) Space Type Height-- 2 Gross Interior Area in ft2 Allowed Watts per ft2 Watts Allowed (watts/ft2 x area) Sales area 11.5 1410 1.270 1791 Total Area Retail Display Lobby Art/Exhibit Display Allowance from LTG -INT -DISPLAY NOTE 8C= 1410 LTG -INT -DISPLAY Allowed Watts Allowance from 1791 Proposed Lighting Wattage NO1t' Location (plan #, room #) Fixture Description NOTE 4, 5, s Number of Watts/ Fixtures Fixture NOTE 7 open spa area LED 2x4 max watts - 62 19 62 drop suspended chandeliers RF/IFWF17 FOR CODE COMPLIANCE 100 DEC' 211IH City of Tukwila Watts Proposed 1178 400 W+epeeaditetai Display Lighting from LTG -INT -DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 1578 Interior Lighting Power Allowance COMPLIES Note 1- List all unique space types per Table C405.4.2(2) that occur in the project scone. Select space type category per from drop down menu. Note 2 - Indicate ceiling height for atriums and soaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f. Note 3 - List all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures. Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamos in the fixture, and ballast type (if included). For track fighting, list the length of the track (in feet) in addition to the fixture, lamo, and ballast information. Note 5 - For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank. Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing in fixture description. Note 7 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaires with screw-in lamps, enterthe manufacturer's listed maximum input wattage of the fixture (not the lamo wattage). For low voltage lighting, enter the wattage of the transfommer. For line voltage track/busway systems, enter the larger of the attached luminaire wattage or 50 watts/lineal foot, or enter the wattage limit of permanent current limiting device. Note 8 - Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. Note 9 - Calculation Area Details: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building lighting systems to demonstrate compliance. Refer to C502.1. b. For alterations and building additions, provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table. If a building addition will comply as combined with the overall existing building lighting systems, include all applicable existing g y , and gross interior areas. CCPV �, E�,�y,!�,� El c. If less than 50% of existing lighting fixtures will be replaced, provide total existing lighting wattage (prior to alteratioi ti s'Vif"'ZG✓�S� Y ILA NUV 14208 x Lijhting Summary 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 LGT-SUM Revised August 2016 Project Info Compliance forms do not require a password to use. Instructional and calculating cells are Project Title: NU Spa and Nail Salon Date 11/1/2018 Applicant Information. Provide contact information for individual who can respond to inquiries about compliance form information provided. For Building Department Use Company Name: Workplace Architecture Company Address: 3025 112th Ave NE Applicant Name: Vicki Somppi write - protected. Applicant Phone: 206-310-0827 FI Applicant Email: vicks@workplacearchitecture.com Project Description 0 Plans Included with lighting complliance forms. New Building Addition 0 Alteration Include PROJ-SUM form (included in envelope forms workbook) Building Additions Refer to Section C502.2.6 for additional requirements. Compliance Method Interior lighting Exterior lighting Lighting systems in addition area comply with all applicable provisions as a stand alone new construction project Lighting systems in addition are combined with existing building lighting systems to demonstrate compliance . ❑ J Addition Is combined with existing: For Interior fighting projects, include new + existing interior lighting fixture wattage in Proposed Lighting Wattage table in LTG -INT -BLD or LTG-iNT-SPACE form. For exterior lighting projects, include new + existing exterior lighting fixture wattage in Proposed Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG -EXT form. Interior Lighting Select Control of combination 50% in fixtures provide compliance conditions. type lighting Refer r A c Mill and Exterior Alterations all Lighting Power and Lighting elements that apply to the scope the retrofit project. If project includes of spaces where less than of the existing fixtures are replaced some spaces, and 50% or more of the are replaced in others, then separate lighting power forms for the two retrofit Spaces undergoing the same of retrofit may be combined into one power compliance form. to Section C503.6 for additional ' •VVE.. - - • REVIEWED FOR • 440 +i:.i r pf�� 1 APPROVED DEC 12 2018 City of Tukwila �: - . ( l a• -Le u the interior or exterior fighting systems and existing space uses and configuration are not changed. a Lighting Power Interior lighting Parking garage Exterior lighting ❑ 50% or more of existing are replaced ./ Less than 50% of existing are replaced ❑ 1=1 Lamp and/or ballast replacement only — existing total wattage not increased ❑ 50% or more replaced - Total lighting power of new + existing LPA per Sections C405.4.2 and C405.5.2. include new + existing Lighting Wattage table in LTG -INT -BLD, LTG -INT -SPACE or Less than 50% replaced - Total lighting power of new + existing total lighting power prior to alteration. Include new + existing -to Wattage table in LTG-iNT-BLD, LTG -INT -SPACE or LTG -EXT 50% threshold applies to number of luminaires for interior .spaces installed wattage for exterior luminaires. 1 ❑ -to -remain fixtures shall comply with total -to -remain fixtures in Proposed LTG -EXT form. -to -remain fixtures shall not exceed the -remain fixtures in the Proposed Lighting form. and parking garages, and total Lighting Controls Interior lighting New wiring installed to serve added Parking garage Exterior lighting ❑ ❑ fixtureand/or fxtures relocated to new circuit(s) New or moved lighting panel 111 M Interior space is reconfigured - ❑ luminaires unchanged or relocated only New wiring or circuit - For interior lighting, provide required manual controls per C405.2.3, occupancy sensor controls per C405.2.1, daylight responsive controls per C405.2.4 and application specific lighting controls per C405.2.5. For exterior lighting, provide required controls per C405.2.7. New or moved panel - Provide all applicable lighting controls as noted for New Wiring and automatic time switch controls per C405.2.2. Reconfigured interior space - Provide all required lighting controls that apply to a new interior space. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured spaces. Change of Space Use ❑ Existing interior lighting systems in areas under -going a change in space use are upgraded to comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2). Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in LTG -INT -BLD or LTG -INT -SPACE form. RECEIVED CiTY OF TUKWILA NUV 14 2018 DCDitAIT f' &i•rr rs Lighting Summary, cont. LGT-S U M 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised August 2016 Project Title: NU Spa and Nail Salon Date 11/1/2018 Interior Lighting System Description Existing lighting to remain for Break area and existing restrooms, extend existing grid thru area removed by landlord from soffit removal. Due to ceiling extension, and new tenant area, new LED lights will be provided in the spa area for 1410 sf Interior Lighting Power Allowance Method 1 Building Area Method a Space -by -space Method Select method used in project. Interior Lighting Controls 1 All C405.2.1 - C405.2.8 Controls 0 C405.2 Exception 5 Luminaire Level Lighting Control (LLLC) Additional Efficiency Package Option C406.4 Enhanced digital lighting controls To comply with C406.4, no less than 90% of the total installed interior lighting power shall comply with the required controls per C406.4. Dwelling Unit Interior Lighting Permanently installed interior lighting fixtures in dwelling units comply with: Q 0 C405.2 thru C405.5 Commercial Lighting Controls and LPA Q C406.3 High Efficacy Lighting 0 Exterior Lighting System Description no changes NT Engineer, 17614 NE 29th St; Redmond, WA 98052 Tel: 425-891-5111 BILE SUBMITTAL PACKAGE TH NAIL BAR AND SPA 12750 SOUTHCENTER PARKWAY, S#136 TUKWILA, WA 98188 CORRECTION BEVStONNOJ 01/31/19 REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 5 2019 City of Tukwila BUILDING DIVISION Ofc-b3(040 RECEIVED CITY OF TUKWILA MAR 2 0 2019 PERMIT CENTER 3/18/19 Rev 1 (Added Lower Ceiling) Project: TH NAIL BAR AND SPA Location: 12750 SOUTHCENTER PARKWAY, S#136 TUKWILA, WA 98188 Date: 01/26/19 Made By: Khoa Nguyen Revision Subject: GENERAL NOTES Sheet #: S1.0 GENERAL STRUCTURAL NOTES 2015 INTERNATION BUILDIN CODE (IBC 2015) CRITERIA 1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, THE INTERNATIONAL BUILDING CODE (IBC)(2015 EDITION). 2. DESIGN LOADING CRITERIA STORE LOAD (UPPER FLOOR) 75 PSF STAIR LIVE LOAD 100 PSF 3. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 4. PRIMARY STRUCTURAL ELEMENTS NOT DIMENSIONED ON THE STRUCTURAL PLANS AND DETAILS SHALL BE LOCATED BY THE ARCHITECTURAL PLANS AND DETAILS. VERTICAL DIMENSION CONTROL IS DEFINED BY THE ARCHITECTURAL WALL SECTIONS, BUILDING SECTIONS, AND PLANS. DETAILING AND SHOP DRAWING PRODUCTION FOR STRUCTURAL ELEMENTS WILL REQUIRE DIMENSIONAL INFORMATION CONTAINED IN BOTH ARCHITECTURAL AND STRUCTURAL DRAWINGS. 5. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS. CONFORM TO ASCE 37-14 "DESIGN LOADS ON STRUCTURES DURING CONSTRUCTION." 6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE CONTRACTORS WORK. THE STRUCTURAL ENGINEER HAS NO OVERALL SUPERVISORY AUTHORITY OR ACTUAL AND/OR DIRECT RESPONSIBILITY FOR THE SPECIFIC WORKING CONDITIONS AT THE SITE AND/OR FOR ANY HAZARDS RESULTING FROM THE ACTIONS OF ANY TRADE CONTRACTOR. THE STRUCTURAL ENGINEER HAS NO DUTY TO INSPECT, SUPERVISE, NOTE, CORRECT, OR REPORT ANY HEALTH OR SAFETY DEFICIENCIES TO THE OWNER, CONTRACTORS, OR OTHER ENTITIES OR PERSONS AT THE PROJECT SITE. 7. CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. ; 8. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARI#OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. 9. ALL STRUCTURAL SYSTEMS WHICH ARE TO BE COMPOSED OF COMPONENTS TO BE FIELD ERECTED SHALL BE SUPERVISED BY THE SUPPLIER DURING MANUFACTURING, DELIVERY, HANDLING, STORAGE AND ERECTION IN ACCORDANCE WITH INSTRUCTIONS PREPARED BY THE SUPPLIER. GEOTECHNICAL 10. ALLOWABLE SOIL PRESSURE ARE REFERENCED FROM RECORD DRAWINGS . IF SOILS ARE FOUND TO BE OTHER THAN SPECIFIED BELOW, NOTIFY THE STRUCTURAL ENGINEER FOR POSSIBLE FOUNDATION REDESIGN. FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED EARTH AT LEAST 18" BELOW ADJACENT FINISHED GRADE. FOOTINGS SHALL BE CENTERED BELOW COLUMNS OR WALLS ABOVE, UNO. • BACKFILL BEHIND ALL RETAINING WALLS WITH FREE DRAINING, GRANULAR FILL AND PROVIDE FOR SUBSURFACE DRAINAGE. ALLbWABLE SOIL PRESSURE 3000 PSF CONCRETE 11. CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AND PLACED IN ACCORDANCE WITH ACI 318 AND ACI 301, INCLUDING TESTING PROCEDURES. CONCRETE SHALL ATTAIN A 28 -DAY STRENGTH OF fc = 3,000 PSI AND MIX SHALL CONTAIN NOT LESS THAN 5-1/2 SACKS OF CEMENT PER CUBIC YARD AND SHALL BE PROPORTIONED TO PRODUCE A SLUMP OF 5" OR LESS. STRUCTURAL DESIGN IS BASED ON A CONCRETE STRENGTH OF fc = 2,500 PSI, THEREFORE NO CONCRETE STRENGTH TESTING REQUIRED. ALL CONCRETE WITH SURFACES EXPOSED TO STANDING WATER SHALL BE AIR -ENTRAINED WITH AN AIR -ENTRAINING AGENT CONFORMING TO ASTM C260, C494, AND C618. TOTAL AIR CONTENT FOR FROST -RESISTANT CONCRETE SHALL BE IN ACCORDANCE WITH ACI 318-11, TABLE 4.4.1. 12. THE MINIMUM AMOUNTS OF CEMENT MAY BE CHANGED IF A CONCRETE PERFORMANCE MIX IS SUBMITTED TO THE STRUCTURAL ENGINEER AND THE BUILDING DEPARTMENT FOR APPROVAL TWO WEEKS PRIOR TO PLACING ANY CONCRETE. THE PERFORMANCE MIX SHALL INCLUDE THE AMOUNTS OF CEMENT, FINE AND COARSE AGGREGATE, WATER AND ADMIXTURES AS WELL AS THE WATER CEMENT RATIO,'SLUMP, CONCRETE YIELD AND SUBSTANTIATING STRENGTH DATA IN ACCORDANCE WITH ACI 318-11 SECTION 5.3. THE USE OF A PERFORMANCE MIX REQUIRES BATCH PLANT INSPECTION, THE COST OF WHICH SHALL BE PAID BY THE GENERAL CONTRACTOR. REVIEW OF MIX SUBMITTALS BY THE ENGINEER OF RECORD INDICATES ONLY THAT INFORMATION PRESENTED CONFORMS GENERALLY WITH CONTRACT DOCUMENTS. CONTRACTOR OR SUPPLIER MAINTAINS FULL RESPONSIBILITY FOR SPECIFIED PERFORMANCE. 13. REINFORCING STEEL SHALL CONFORM TO ASTM A615 (INCLUDING SUPPLEMENT 51), GRADE 60, fy = 60,000 PSI. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A1064. SPIRAL REINFORCEMENT SHALL BE DEFORMED DEFORMED WIRE CONFORMING TO ASTM A615, GRADE 60, fy = 60,000 PSI. 14. DETAILING OF REINFORCING STEEL (INCLUDING HOOKS AND BENDS) SHALL BE IN ACCORDANCE WITH ACI 315-99 AND 318-11. LAP ALL CONTINUOUS REINFORCEMENT #6 AND SMALLER 40 BAR DIAMETERS OR 2'-0" MINIMUM. PROVIDE CORNER BARS AT ALL WALL AND FOOTING INTERSECTIONS. LAP CORNER BARS #5 AND SMALLER 40 BAR DIAMETERS OR 2'-0" MINIMUM. LAPS OF LARGER BARS SHALL BE MADE IN ACCORDANCE WITH ACI 318-11, CLASS B. LAP ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM OF 8" AT SIDES AND ENDS. NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY SO DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. Project: TH NAIL BAR AND SPA Location: 12750 SOUTHCENTER PARKWAY, S#136 TUKWILA, WA 98188 Date: 01/26/19 Made By: Khoa Nguyen Revision Subject: GENERAL NOTES Sheet #: S1.1 15. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS: FOOTINGS AND OTHER UNFORMED SURFACES CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH ;; 3" FORMED SURFACES EXPOSED TO EARTH OR WEATHER (#6 BARS OR LARGER) 2" FORMED SURFACES EXPOSED TO EARTH OR WEATHER (#5 BARS OR SMALLER) 1-1/2" COLUMN TIES OR SPIRALS AND BEAM STIRRUPS 1-1/2" SLABS AND WALLS (INT FACE) GREATER OF BAR DIAMETER PLUS 1/8" OR 3/4" CONCRETE SLAB ON GRADE: 16. THE SLABS -ON -GRADE SHOULD BEAR ON A MINIMUM OF 4 -INCH -THICK, FREE -DRAINING, CLEAN, CRUSHED, GRAVEL BASE (TYPE 22 MATERIAL). A ROBUST VAPOR RETARDER SUCH AS 10 -MIL POLYETHYLENE SHEETING SHALL BE INCLUDED BENEATH THE SLAB TO MINIMIZE TRANSMISSION OF MOISTURE THROUGH THE CONCRETE FLOOR. A MINIMUM, TWO-INCH THICK LAYER OF CLEAN SAND WITH LESS THAN 3 PERCENT FINES MAY BE PLACED ON TOP OF THE POLYETHYLENE SHEETING TO PROTECT THE SHEETING AND TO ENHANCE THE CURING OF THE CONCRETE SLABS. LIGHT GAUGE STEEL STUDS AND JOISTS: 17. COLD -FORMED STEEL FRAMING SHALL CONFORM TO ALL REQUIREMENTS OF THE LATEST EDITION OF THE A.I.S.I SPECIFICATIONS FOR THE "DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS". 18. ALL WELDING SHALL BE IN CONFORMANCE WITH AWS D1.3, "STRUCTURAL WELDING CODE - SHEET STEEL." QUALIFICATION OF WELDERS SHALL BE IN ACCORDANCE WITH AWS D1.1, CHAPTER 5, PART C, "WELDER QUALIFICATION." 19. STEEL SECTIONS ARE TO BE FORMED FROM STEEL HAVING A MINIMUM 33,000 P51 YIELD POINT (ASTM A 446-83 GRADE A OR ASTM A 570-79 GRADE 33) FOR THICKNESSES OF 0.0172 INCH THROUGH 0.0451 INCH (NO. 18 GAUGE) AND MINIMUM 50,000 PSI YIELD POINT (ASTM A 446-83 GRADE D OR ASTM A 570-79 GRADE 50) FOR THICKNESSES OF 0.0566 INCH (NO. 16 GAUGE) THROUGH 0.1285 INCH (N0.10 GAUGE). GALVANIZED COATING TO COMPLY WITH ASTM A 525-79. 20. FRAMING SHALL BE ERECTED PLUMB, LEVEL, AND SQUARE. BRIDGING AND DIAGONAL TENSION STRAPS SHALL BE USED ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. 21. TEMPORARY BRACING SHALL BE PROVIDED AS REQUIRED UNTIL ERECTION IS COMPLETE AND SAFELY SECURED TO STRUCTURE. 22. MEMBER SIZES SHOWN ON THE DRAWINGS SHALL MEET THE MINIMUM SECTIONAL PROPERTIES PROVIDED ON THE LATEST VERSION OF "SSMA PRODUCT TECHNICAL GUIDE" ANCHORAGE 23. EPDXY-GROUTED ITEMS (THREADED RODS OR REINFORCING BAR) SPECIFIED ON THE DRAWINGS SHALL BE INSTALLED USING "HIT HY200" EPDXY ADHESIVE AS MANUFACTURED BY THE HILTI COMPANY. INSTALL IN STRICT ACCORDANCE WITH ICC -ES REPORT ESR -3187. SUBSTITUTIONS PROPOSED BY THE CONTRACTOR SHALL BE SUBMITTED FOR REVIEW WITH CURRENT ICC REPORTS INDICATING EQUIVALENT OR GREATER LOAD CAPACITIES. SPECIAL INSPECTION OF INSTALLATION IS REQUIRED. RODS SHALL BE ASTM A-36, UNO. 24. HEAVY DUTY THREADED CONCRETE ANCHORS SPECIFIED ON THE DRAWINGS SHALL BE "TITEN HD SCREW ANCHOR" AS MANUFACTURED BY THE SIMPSON STRONG TIE COMPANY. INSTALL IN STRICT ACCORDANCE WITH ICC -ES REPORT ESR -2713, INCLUDING MINIMUM EMBEDMENT AND EDGE DISTANCE REQUIREMENTS. SUBSTITUTIONS PROPOSED BY THE CONTRACTOR SHALL BE SUBMITTED FOR REVIEW WITH ICC REPORTS INDICATING EQUIVALENT OR GREATER LOAD CAPACITIES. 25. EXPANSION BOLTS INTO CONCRETE AND CONCRETE MASONRY UNITS SHALL BE "STRONG -BOLT" ANCHORS AS MANUFACTURED BY THE SIMPSON STRONG TIE COMPANY AND INSTALLED IN STRICT CONFORMANCE TO ICC -ES REPORT ESR -1771, INCLUDING MINIMUM EMBEDMENT REQUIREMENTS. BOLTS INTO CONCRETE MASONRY OR BRICK MASONRY UNITS SHALL BE INTO FULLY GROUTED CELLS. SPECIAL INSPECTION IS REQUIRED FOR ALL EXPANSION BOLT INSTALLATION. 26. DRIVE PINS AND OTHER POWDER -ACTUATED FASTENERS SHALL BE LOW VELOCITY TYPE (PDPWL- 300MG, 0.145' DIAMETER, UNO) AS MANUFACTURED BY THE SIMPSON STRONG TIE COMPANY OR AN APPROVED EQUIVALENT IN STRENGTH AND EMBEDMENT. INSTALL IN STRICT ACCORDANCE WITH ICC -ES REPORT ESR -2138. MINIMUM EMBEDMENT IN CONCRETE SHALL BE 1", UNO. MAINTAIN AT LEAST 3" TO NEAREST CONCRETE EDGE. FINISH SURFACE TRACK BLOCK PIECE TO MATCH WALL STUD CLIP FLANGE AND BEND INSTALL 10' O.C. / FRAMED WALL r*.,% 11#4(1° SCREW 41 ATTACHMENT TAUT FLAT STRAP (NOT REQUIRED IF SHEATHING ON BOTH SIDES OF STUD) Bridging Single Flat Strap With Blocking SCREW ATTACHMENT CLIP ANGLE [LENGTH = 80% OF STUD DEPTH (d)] COLD -ROLLED CHANNEL Bridging Cold -rolled Channel With Clip Angle REQUIRED FASTENERS PER WALL SECTION OR DETAIL END OF TRACKS STUD �� /1..) SELF -DRILLING SCREW 111 ' :aON EACH SIDE 1 Ofr e010.°0° A ° ° BASE TRACK *10* c� 92 SCHEDULE OR SECT. -F WEDGE ANCHOR PER Bottom Track Anchorage Project: Location: TH NAIL BAR AND SPA 12750 SOUTHCENTER PARKWAY, S#136 TUKWILA, WA 98188 Date: 01/26/19 Made By: Khoa Nguyen Revision Subject: Wall Bridging & Bottom Track Details Sheet #: FINISH SURFACE TRACK BLOCK PIECE TO MATCH WALL STUD CLIP FLANGE AND BEND INSTALL 10' O.C. / FRAMED WALL r*.,% 11#4(1° SCREW 41 ATTACHMENT TAUT FLAT STRAP (NOT REQUIRED IF SHEATHING ON BOTH SIDES OF STUD) Bridging Single Flat Strap With Blocking SCREW ATTACHMENT CLIP ANGLE [LENGTH = 80% OF STUD DEPTH (d)] COLD -ROLLED CHANNEL Bridging Cold -rolled Channel With Clip Angle REQUIRED FASTENERS PER WALL SECTION OR DETAIL END OF TRACKS STUD �� /1..) SELF -DRILLING SCREW 111 ' :aON EACH SIDE 1 Ofr e010.°0° A ° ° BASE TRACK *10* c� 92 SCHEDULE OR SECT. -F WEDGE ANCHOR PER Bottom Track Anchorage Project: TH NAIL BAR AND SPA Location: 12750 SOUTHCENTER PARKWAY, S#136 TUKWILA, WA 98188 Date: 01/26/19 Made By: Khoa Nguyen Revision INFILL STUD HEADER TRACKS HEADER MEMBERS Subject: Headers, Sills & Jambs Details Sheet #: SILL INFILL STUD TYPICAL BASE ANCHORAGE ANGLE 440P010. ADDITIONAL ANCHORAGE @ JAMB CRIPPLE STUD 2" . 24" o.c. 2" @ 24" o.c. JAMB CRIPPLE STUD BASE TRACK Window - Header, Sills & Jambs NESTED JAMB SDS @ 16" O.C. ON EA SIDE SDS @ 16" O.C. ON EA SIDE NESTED JAMB NESTED HEADER INFILL STUD SDS @ EA SIDE SDS @ 16" O.C. ON EA SIDE INFILL STUD BOX HEADER (2) SDS @ 16" O.C. ON EA SIDE TOP & BOTTOM INFILL STUD BOX HEADER (2) SDS @ 16" 0.C. ON EA SIDE TOP & BOTTOM E) )EMISING VALL 8. V)FURRED >UT WALL 1 • NEW FOOTING --R'?.€!E - 0 N A V MEZZ BEARNG WALL 7/16" SHEATHING ERGENCY EGRESS MIN, 44" WIDE ;YR. 92 SF. / / / / / / / / ELEV so) WAX NEW FOOTING 105 SF. 9 N 7/16" SHEATHING MEZZ BEARNG WALL / / J / / - F ■ UP (00 JAMB STUD (2)400S200-54 STO"AGE BOX 1 131 SF. DRY WS (E)ELEC. 0 N 14'-0" J0 r II��.: MEZZ NON-BEARNG WALL REST ROOM1 53 SF. 4:-3" s REST JOM2 53 SF. v-1 26.-10„ 3.2 FLOOR PLAN NORTH Project: Location: TH NAIL BAR AND SPA 12750 SOUTHCENTER PARKWAY, S#136 TUKWILA, WA 98188 Date: 01/26/19 Made By: Khoa Nguyen Revision Subject: FLOOR PLAN Sheet #: S2.0 E) )EMISING VALL 8. V)FURRED >UT WALL 1 • NEW FOOTING --R'?.€!E - 0 N A V MEZZ BEARNG WALL 7/16" SHEATHING ERGENCY EGRESS MIN, 44" WIDE ;YR. 92 SF. / / / / / / / / ELEV so) WAX NEW FOOTING 105 SF. 9 N 7/16" SHEATHING MEZZ BEARNG WALL / / J / / - F ■ UP (00 JAMB STUD (2)400S200-54 STO"AGE BOX 1 131 SF. DRY WS (E)ELEC. 0 N 14'-0" J0 r II��.: MEZZ NON-BEARNG WALL REST ROOM1 53 SF. 4:-3" s REST JOM2 53 SF. v-1 26.-10„ 3.2 FLOOR PLAN NORTH MW REF I MEZZ BEARNG WALL BELOW r---7 600$16268 1_6' oc TYP MEZZANINE 242 SF. B1 CO DN 13'-2" MEZZ BEARNG WALL BELOW NOTE: REF SHEETS S4.0 AND S4.1 FOR JOIST/BEAM/POST CONNECTION DETAILS. MEZZ FLOOR PLAN 0 NORTH Project: Location: TH NAIL BAR AND SPA 12750 SOUTHCENTER PARKWAY, S#136 TUKWILA, WA 98188 Date: 01/26/19 Made By: Khoa Nguyen Revision Subject: MEZZ FLOOR PLAN Sheet #: S2.1 MW REF I MEZZ BEARNG WALL BELOW r---7 600$16268 1_6' oc TYP MEZZANINE 242 SF. B1 CO DN 13'-2" MEZZ BEARNG WALL BELOW NOTE: REF SHEETS S4.0 AND S4.1 FOR JOIST/BEAM/POST CONNECTION DETAILS. MEZZ FLOOR PLAN 0 NORTH 0 0' 4'-9" 17'-5" 4'-9" (E) 28K STEEL JOIST, TYP. 3 4 (2)362S200-43 TYP 8 LOCATIONS AS SHOWN. 2'-5 12'-7" 2'-5" o' N 1 I N 362S162-43 @ 24" oc, TYP. INDICATES (2)362S200-43 w/ BRACE, 4 LOCATIONS TOTAL I RADIUS ITRACK362T150-43 @ 24" oc, REF DETAIL ON S4.2, TYP CEILING FRAMING PLAN NORTH Project: Location: TH NAIL BAR AND SPA 12750 SOUTHCENTER PARKWAY, S#136 TUKWILA, WA 98188 Date: 01/26/19 Made By: Khoa Nguyen Revision Subject: CEILING FRAMING PLAN Sheet #: S2.2 0 0' 4'-9" 17'-5" 4'-9" (E) 28K STEEL JOIST, TYP. 3 4 (2)362S200-43 TYP 8 LOCATIONS AS SHOWN. 2'-5 12'-7" 2'-5" o' N 1 I N 362S162-43 @ 24" oc, TYP. INDICATES (2)362S200-43 w/ BRACE, 4 LOCATIONS TOTAL I RADIUS ITRACK362T150-43 @ 24" oc, REF DETAIL ON S4.2, TYP CEILING FRAMING PLAN NORTH 01, ROOF MEZZ REF ARCH RIM TRACK 600T200-68 CONT w/ #8 SCREW TO EA JOIST TOP AND BOTTOM 16" SHEATHING w/ ETF PINS AGS -100 @ 6" oc ALL EDGES AND 9" oc FILLER AREA WHERE SHOWN ON PLAN SAWCUT (E) SLAB TO INSTALL NEW FOOTING ON COMPACTED SOIL. WATER PROOFING BY CONTRACTOR SOG 0.0 II II II II II I Y I 14GA SLIP -TRACK w/ (2) 0.145" DIA PAF TO EA OVERHEAD TRUSS 600S162-43 at 16" o.c NON-BEARING WALL 600T125-43 w/ (2) #8 SCREWS TO EA JOIST (E) ROOF JOIST 4 USG STRUCTURAL PANEL SUBFLOOR O 0 — -- `–JOIST PER PLAN, JOIST SHALL BE PLACED TO 600T125-68 LINE UP WITH THE STUD WALL w/#8 SCREW TO BELOW STUD EA SIDE 600S162-54 at 16" o.c BEARING WALL 600T125-54 w/ 1/4" DIA HILTI HUS EZ SCREW TO CONCRETE @ 16" oc, 1 1/4" EMBED #5 @ 12" oc (3)#4 CONT (E) SLAB MEZZ SECTION - BEARING WALL Project: Location: TH NAIL BAR AND SPA 12750 SOUTHCENTER PARKWAY, S#136 TUKWILA, WA 98188 Date: 01/26/19 Made By: Khoa Nguyen Revision Subject: MEZZ SECTION Sheet #: S3.0 01, ROOF MEZZ REF ARCH RIM TRACK 600T200-68 CONT w/ #8 SCREW TO EA JOIST TOP AND BOTTOM 16" SHEATHING w/ ETF PINS AGS -100 @ 6" oc ALL EDGES AND 9" oc FILLER AREA WHERE SHOWN ON PLAN SAWCUT (E) SLAB TO INSTALL NEW FOOTING ON COMPACTED SOIL. WATER PROOFING BY CONTRACTOR SOG 0.0 II II II II II I Y I 14GA SLIP -TRACK w/ (2) 0.145" DIA PAF TO EA OVERHEAD TRUSS 600S162-43 at 16" o.c NON-BEARING WALL 600T125-43 w/ (2) #8 SCREWS TO EA JOIST (E) ROOF JOIST 4 USG STRUCTURAL PANEL SUBFLOOR O 0 — -- `–JOIST PER PLAN, JOIST SHALL BE PLACED TO 600T125-68 LINE UP WITH THE STUD WALL w/#8 SCREW TO BELOW STUD EA SIDE 600S162-54 at 16" o.c BEARING WALL 600T125-54 w/ 1/4" DIA HILTI HUS EZ SCREW TO CONCRETE @ 16" oc, 1 1/4" EMBED #5 @ 12" oc (3)#4 CONT (E) SLAB MEZZ SECTION - BEARING WALL ROOF 362T125-43 w/ (2)0.145 DIA PAF TO JOIST BOT CHORD MEZZ REF ARCH SHEATHING w/ ETF PINS AGS -100 @ 6" oc ALL EDGES AND 9" oc FILLER AREA WHERE SHOWN ON PLAN 4 SOG 0.0 362S162-43 @ 48" oc 14GA SUP -TRACK w/ (2) #8 SCREWS TO OVERHEAD STUD 600S162-43 at 16" o.c NON-BEARING WALL 6007125-43 w/ (2)#8 SCREWS TO BLOCKING 16GA CLIP 4"X4" W/ (3) #8 SCREWS TO BRACE, AND (2) 0.145" DIA PAF TO JOIST TOP CHORD (E) ROOF JOIST BLOCKING TO MATCH JOIST SIZE AND GAUGE P@ 16"oc " USG STRUCTURAL PANEL SUBFLOOR 6007125-43 600S162-43 at 16" o.c NON-BEARING WALL JOIST PER PLAN, 600T125-43 w/ 0.145" DIA PAF @ 16"o.c. TO CONCRETE, 14" EMBED (E) SLAB MEZZ SECTION - NON BEARING WALL Project: Location: TH NAIL BAR AND SPA 12750 SOUTHCENTER PARKWAY, S#136 TUKWILA, WA 98188 Date: 01/26/19 Made By: Khoa Nguyen Revision Subject: MEZZ SECTION Sheet #: S3.1 ROOF 362T125-43 w/ (2)0.145 DIA PAF TO JOIST BOT CHORD MEZZ REF ARCH SHEATHING w/ ETF PINS AGS -100 @ 6" oc ALL EDGES AND 9" oc FILLER AREA WHERE SHOWN ON PLAN 4 SOG 0.0 362S162-43 @ 48" oc 14GA SUP -TRACK w/ (2) #8 SCREWS TO OVERHEAD STUD 600S162-43 at 16" o.c NON-BEARING WALL 6007125-43 w/ (2)#8 SCREWS TO BLOCKING 16GA CLIP 4"X4" W/ (3) #8 SCREWS TO BRACE, AND (2) 0.145" DIA PAF TO JOIST TOP CHORD (E) ROOF JOIST BLOCKING TO MATCH JOIST SIZE AND GAUGE P@ 16"oc " USG STRUCTURAL PANEL SUBFLOOR 6007125-43 600S162-43 at 16" o.c NON-BEARING WALL JOIST PER PLAN, 600T125-43 w/ 0.145" DIA PAF @ 16"o.c. TO CONCRETE, 14" EMBED (E) SLAB MEZZ SECTION - NON BEARING WALL ROOF (E) CONC WALL MEZZ REF ARCH RIM TRACK 600T200-68 CONT w/ #8 SCREW TO EA JOIST TOP AND BOTTOM, (2) i" DIA HILTI HUS EZ SCREWS TO CONC PANEL @ 16" oc .e a, v V'e e4 de . (E) ROOF JOIST a" USG STRUCTURAL PANEL SUBFLOOR JOIST PER PLAN, 16GA CLIP 2"x2" x 0'-5" w/ (3) #8 SCREWS TO JOIST, AND (2)'a" DIA HILTI HUS EZ SCREWS TO CONC MEZZ SECTION - BEARING WALL Project: Location: TH NAIL BAR AND SPA 12750 SOUTHCENTER PARKWAY, S#136 TUKWILA, WA 98188 Date: 01/26/19 Made By: Khoa Nguyen Revision Subject: MEZZ SECTION Sheet#: S3.2 ROOF (E) CONC WALL MEZZ REF ARCH RIM TRACK 600T200-68 CONT w/ #8 SCREW TO EA JOIST TOP AND BOTTOM, (2) i" DIA HILTI HUS EZ SCREWS TO CONC PANEL @ 16" oc .e a, v V'e e4 de . (E) ROOF JOIST a" USG STRUCTURAL PANEL SUBFLOOR JOIST PER PLAN, 16GA CLIP 2"x2" x 0'-5" w/ (3) #8 SCREWS TO JOIST, AND (2)'a" DIA HILTI HUS EZ SCREWS TO CONC MEZZ SECTION - BEARING WALL Project: TH NAIL BAR AND SPA Location: 12750 SOUTHCENTER PARKWAY, S#136 TUKWILA, WA 98188 Date: 01/26/19 Made By: Khoa Nguyen Revision Subject: CEILING FRAMING SECTION Sheet #: S3.3 CEILING FRAMING SECTION o 8 27 0I- m w gOw w 030) WO I7 F Project: Location: TH NAIL BAR AND SPA 12750 SOUTHCENTER PARKWAY, S#136 TUKWILA, WA 98188 Date: 01/26/19 Made By: Khoa Nguyen Revision Subject: CEILING FRAMING ELEVATION Sheet#: S3.4 o 8 27 0I- m w gOw w 030) WO I7 F 362S162.4 wow 0 u 3 Q Q 00 00 . § W O CEILING FRAMING ELEVATION 1.+ i L 1 m Q 2 w O L + V g K d8 v //J 362S162.4 wow 0 u 3 Q Q 00 00 . § W O CEILING FRAMING ELEVATION Project: Location: TH NAIL BAR AND SPA 12750 SOUTHCENTER PARKWAY, S#136 TUKWILA, WA 98188 Date: 01/26/19 Made By: Khoa Nguyen Revision Subject: CEILING FRAMING SECTION Sheet #: S3.5 Project: Location: TH NAIL BAR AND SPA 12750 SOUTHCENTER PARKWAY, S#136 TUKWILA, WA 98188 Date: 01/26/19 Made By: Khoa Nguyen Revision Subject: CEILING FRAMING SECTION Sheet #: S3.6 4 ROOF 12'-0" AFF 10'-0" AFF 362T150-43 w/ (2)0.145 DIA PAF TO JOIST, TYP. TRUSS BRACE SIM TO DETAIL 22/S1 E 3625162-43 CONT (2)362S200-43 BOX C` 362S162-43 @24" oc 362S162-43 @24" oc--/ (2) #8 SCREWS 362T125-43 CONT W/ (2) #8 SCREWS TO (E) WALL @ 24" OC. (E) DEMISING WALL '-0" MAX HALF PIPE CEILING REF DETAIL 81S2 1 CEILING FRAMING ELEVATION 8 S3 7(E) ROOF J01 T Project: Location: TH NAIL BAR AND SPA 12750 SOUTHCENTER PARKWAY, S#136 TUKWILA, WA 98188 Date: 01/26/19 Made By: Khoa Nguyen Revision Subject: CEILING FRAMING PLAN Sheet #: 4 ROOF 12'-0" AFF 10'-0" AFF 362T150-43 w/ (2)0.145 DIA PAF TO JOIST, TYP. TRUSS BRACE SIM TO DETAIL 22/S1 E 3625162-43 CONT (2)362S200-43 BOX C` 362S162-43 @24" oc 362S162-43 @24" oc--/ (2) #8 SCREWS 362T125-43 CONT W/ (2) #8 SCREWS TO (E) WALL @ 24" OC. (E) DEMISING WALL '-0" MAX HALF PIPE CEILING REF DETAIL 81S2 1 CEILING FRAMING ELEVATION 8 S3 7(E) ROOF J01 T ROOF �i 12'-0" AFF 1 (E) ROOF JOIN 7 16GA CLIP 2"X4" W/ (3) #8 SCREWS TO STUD, AND (2) 1/4" DIA SCREW ANCHOR TO JOIST BOTTOM CHORD 3625162-43 @24" oc (2)#8 SCREWS 362S162-43 @24" oc 362T125-43 CONT W/ (2) #8 SCREWS TO (E) WALL @ 24" OC.. (E) DEMISING WALL CEILING FRAMING ELEVATION10 S3 Project: Location: TH NAIL BAR AND SPA 12750 SOUTHCENTER PARKWAY, S#136 TUKWILA, WA 98188 Date: 01/26/19 Made By: Khoa Nguyen Revision Subject: CEILING FRAMING PLAN Sheet #: ROOF �i 12'-0" AFF 1 (E) ROOF JOIN 7 16GA CLIP 2"X4" W/ (3) #8 SCREWS TO STUD, AND (2) 1/4" DIA SCREW ANCHOR TO JOIST BOTTOM CHORD 3625162-43 @24" oc (2)#8 SCREWS 362S162-43 @24" oc 362T125-43 CONT W/ (2) #8 SCREWS TO (E) WALL @ 24" OC.. (E) DEMISING WALL CEILING FRAMING ELEVATION10 S3 TYP JAMB STUD POST DETAIL TRACK TRACK 14GA CLIP 5"x4.5"EACH SIDE w/ (8) #10 SCREWS TO POST, (4) #10 SCREWS TO BEAM 4005200-54 BOXED POST REF PLAN 1/4" GAP MAX SCREW OPTION REF ARCH MEZZ BOXED BEAM REF PLAN B1 BEAM TO POST DETAIL 146A CLIP 5"x4.5"EACH SIDE w/ (10) #10 SCREWS TO POST, (5) #10 SCREWS TO BEAM (2) 6005300-54 BOXED POST REF PLAN 1/4" GAP MAX SCREW OPTION REF ARCH MEZZ B2 BOXED BEAM REF PLAN B2 BEAM TO POST DETAIL Project: Location: TH NAIL BAR AND SPA 12750 SOUTHCENTER PARKWAY, S#136 TUKWILA, WA 98188 Date: 01/26/19 Made By: Khoa Nguyen Revision Subject: DETAILS Sheet #: S4.0 TYP JAMB STUD POST DETAIL TRACK TRACK 14GA CLIP 5"x4.5"EACH SIDE w/ (8) #10 SCREWS TO POST, (4) #10 SCREWS TO BEAM 4005200-54 BOXED POST REF PLAN 1/4" GAP MAX SCREW OPTION REF ARCH MEZZ BOXED BEAM REF PLAN B1 BEAM TO POST DETAIL 146A CLIP 5"x4.5"EACH SIDE w/ (10) #10 SCREWS TO POST, (5) #10 SCREWS TO BEAM (2) 6005300-54 BOXED POST REF PLAN 1/4" GAP MAX SCREW OPTION REF ARCH MEZZ B2 BOXED BEAM REF PLAN B2 BEAM TO POST DETAIL ROOF 362S200-43 EA SIDE OF VERT DROP, TYP AT EA (E) JOIST 16GA CLIP 2"X4" W/ (3) #8 SCREWS TO STUD, AND (2) i" DIA HILTI KH -EZ SCREWS TO CONC PANEL 12'-0" AFF 4 /(E) ROOF JOIST (E) CONC PANEL a L •e • 0 . 16GA CLIP 2"X4 REF DETAIL 8,E (3) 1/4" DIA SCREW ANCHOR 10 JOIST BOTTOM CHORD TYP. 362S162-43 CONT w/ (2)i" DIA HILTI KH -EZ SCREWS TO CONC PANEL @ 24" OC 362S162-43 CONT \ @24" oc w/ (2)#8 TO EA VERT DROP 3 \3625162-43 24"c REF DETAIL 8/S2 362S162-43 DROP @24" oc TYP AT EA (E) JOIST 3625162-33 BLOCKING @ 48" oc L_ 10'-0" AFF CEILING FRAMING ELEVATION Project: Location: TH NAIL BAR AND SPA 12750 SOUTHCENTER PARKWAY, S#136 TUKWILA, WA 98188 Date: 01/26/19 Made By: Khoa Nguyen Revision Subject: CEILING FRAMING PLAN Sheet #: ROOF 362S200-43 EA SIDE OF VERT DROP, TYP AT EA (E) JOIST 16GA CLIP 2"X4" W/ (3) #8 SCREWS TO STUD, AND (2) i" DIA HILTI KH -EZ SCREWS TO CONC PANEL 12'-0" AFF 4 /(E) ROOF JOIST (E) CONC PANEL a L •e • 0 . 16GA CLIP 2"X4 REF DETAIL 8,E (3) 1/4" DIA SCREW ANCHOR 10 JOIST BOTTOM CHORD TYP. 362S162-43 CONT w/ (2)i" DIA HILTI KH -EZ SCREWS TO CONC PANEL @ 24" OC 362S162-43 CONT \ @24" oc w/ (2)#8 TO EA VERT DROP 3 \3625162-43 24"c REF DETAIL 8/S2 362S162-43 DROP @24" oc TYP AT EA (E) JOIST 3625162-33 BLOCKING @ 48" oc L_ 10'-0" AFF CEILING FRAMING ELEVATION 12'-0" AFF 10'-0" AFF 362S162-43 @24" oc (2)#8 SCREWS 362T125-43 CONT W/ (2) #8 SCREWS TO WALL @ 24" OC. (E) PARTITION WALL CEILING FRAMING ELEVATION 14 S3 Project: Location: TH NAIL BAR AND SPA 12750 SOUTHCENTER PARKWAY, S#136 TUKWILA, WA 98188 Date: 01/26/19 Made By: Khoa Nguyen Revision Subject: CEILING FRAMING PLAN Sheet* 12'-0" AFF 10'-0" AFF 362S162-43 @24" oc (2)#8 SCREWS 362T125-43 CONT W/ (2) #8 SCREWS TO WALL @ 24" OC. (E) PARTITION WALL CEILING FRAMING ELEVATION 14 S3 HOT WATER & COLD WATER INSULATE WITH FIBERGLASS BATTS NOT FOAM INSULATION BLOCK SADDLE BETWEEN HEATER AND WALL 2/3 HEIGHT OF WATER HEATER UNIONS OR FLEX. CONNECTOR SPILL FULL SIZE TEMPERATURE & PRESSURE RELIEF TO OUTSIDE GAS COCK 1/3 HEIGHT OF WATER HEATER #8 SCREW POSITIVELY ATTACHED TO METAL STUD WALL. TYPICAL AT 1/3 AND 2/3 HEIGHT OF HEATER 1 3/8" X 16 GAUGE STRAP, MIN. 2" RIGID INSULATION UNION TYP. OR FLEX. CONNECTOR NOTE: USE 3 STRAPS ON 75 GALLON AND GREATER SIZES WATER HEATER STRAPS Project: Location: TH NAIL BAR AND SPA 12750 SOUTHCENTER PARKWAY, S#136 TUKWILA, WA 98188 Date: 01/26/19 Made By: Khoa Nguyen Revision Subject: CEILING FRAMING PLAN Sheet #: HOT WATER & COLD WATER INSULATE WITH FIBERGLASS BATTS NOT FOAM INSULATION BLOCK SADDLE BETWEEN HEATER AND WALL 2/3 HEIGHT OF WATER HEATER UNIONS OR FLEX. CONNECTOR SPILL FULL SIZE TEMPERATURE & PRESSURE RELIEF TO OUTSIDE GAS COCK 1/3 HEIGHT OF WATER HEATER #8 SCREW POSITIVELY ATTACHED TO METAL STUD WALL. TYPICAL AT 1/3 AND 2/3 HEIGHT OF HEATER 1 3/8" X 16 GAUGE STRAP, MIN. 2" RIGID INSULATION UNION TYP. OR FLEX. CONNECTOR NOTE: USE 3 STRAPS ON 75 GALLON AND GREATER SIZES WATER HEATER STRAPS BOXED BEAM SCHEDULE Project: Location: TH NAIL BAR AND SPA 12750 SOUTHCENTER PARKWAY, S#136 TUKWILA, WA 98188 Date: 01/26/19 Made By: Khoa Nguyen Revision Subject: DETAILS Sheet #: S4.1 BOXED BEAM SCHEDULE MARK SIZE WELD "A" 51 (2) 6005200-54 2 - 12 B2 (2) 6005300-68 3 - 12 BOXED BEAM, REF SCHED TYP 1/8 16GA CLIP 2 1/2" x 2 1/2" x 0'-5" w/ (3) *10 SCREWS EA LEG BOXED BEAM REF PLAN REF ARCH MEZZ JOIST REF PLAN 600T125-54 CANT w/ (3) #10 SCREWS TO BOXED @ 1b"oc BEAM TO JOIST CONNECTION 14GA CLIP 2 1/2" x 2 1/2" x 0'-6" EACH SIDE w/ (4) #10 SCREWS EA LEG, TYP REF ARCH MEZZ BEAM TO BEAM CONNECTION BEAM CONNECTION DETAIL STRAP WITH (1) #1 0— 1 6 SCREW AT EACH END OF EACH TRACK LEG SECTION TYPICAL TRACK CUT AND BEND TO FORM RADIUS NOTES: 1) CUT AND BEND TRACK AT MIDPOINT BETWEEN STUDS. 2) STUDS NOT SHOWN FOR CLARITY. 3) NO STUD SHALL OCCUR WITHIN 4" OF A CUT. RADIUS TRACK DETAIL Project: Location: TH NAIL BAR AND SPA 12750 SOUTHCENTER PARKWAY, S#136 TUKWILA, WA 98188 Date: 01/26/19 Made By: Khoa Nguyen Revision Subject: CEILING FRAMING PLAN Sheet #: S4.2 STRAP WITH (1) #1 0— 1 6 SCREW AT EACH END OF EACH TRACK LEG SECTION TYPICAL TRACK CUT AND BEND TO FORM RADIUS NOTES: 1) CUT AND BEND TRACK AT MIDPOINT BETWEEN STUDS. 2) STUDS NOT SHOWN FOR CLARITY. 3) NO STUD SHALL OCCUR WITHIN 4" OF A CUT. RADIUS TRACK DETAIL SCAFCO Steel Stud Mfg. 2007 North American Specification [AISI S100] ASD DATE: 1/26/2019 MEZZ JOIST SECTION DESIGNATION: 600S162-68 [50] Single Input Properties: Web Height = Top Flange = Bottom Flange = Stiffening Lip = Punchout Width = Floor Solver Design Data - Simple Span Joist Span 10.00 ft Dead Load = 15.0 psf Live Load = 75.0 psf 6.000 in 1.625 in 1.625 in 0.500 in 1.500 in Design Thickness = Inside Corner Radius = Yield Point, Fy = Fy With Cold -Work, Fya = Punchout Length = Joist Spacing 16.0 in Check Flexure Mmax = 1500 Ft -Lb <= Ma = 3289 Ft -Lb & Ma(distortional) = 2975 Ft -Lb K -phi for Distortional Buckling = 0 Ib*in/in Check Deflection Total Load Defl Limit: L/360 Total Load Defl. = 0.260 in Live Load Defl Limit: L/400 Live Load Defl. = 0.216 in Total Load Defl. Ratio = L/462 Live Load Defl. Ratio = L/555 Check Web Crippling Web Crippling capacity not reduced for punchouts near ends of member Rmax = 600 Ib End Bearing Length = 1.00 in Ra = 914 Ib >= Rmax, stiffeners not required Check Shear Vmax = 600 Ib Shear capacity not reduced for punchouts near ends of member Va = 5350 Ib >= Vmax 0.0713 in 0.1070 in 50.0 ksi 56.6 ksi 4.000 in SCAFCO Steel Stud Mfg. 2007 North American Specification [AISI S100] ASD DATE: 1/27/2019 MEZZ BEAM B1 SECTION DESIGNATION: 600S200-54 [50] (2) Boxed Input Properties: Web Height = Top Flange = Bottom Flange = Stiffening Lip = Punchout Width = Header/Beam Solver Design Data Header/Beam Span 6.00 ft Dead Load = 60.0 Ib/ft Live Load = 270.0 Ib/ft 6.000 in 2.000 in 2.000 in 0.625 in 1.500 in - Simple Span Check Flexure Input Flexural Bracing: None Cb = 1.14 lyy (Box) = 3.150 inA4 J (Box) = 6.289 in^4 Lu = 944.0 in Mmax = 1485 Ft -Lb <= Ma = 5066 Ft -Lb Check Deflection Deflection Limit: L/360 Maximum Deflection = 0.049 in Design Thickness = Inside Corner Radius = Yield Point, Fy = Fy With Cold -Work, Fya = Punchout Length = Deflection Limit L/360 DL Multiplied by 1.00 for Strength Checks LL Multiplied by 1.00 for Strength Checks Deflection Ratio = L/1465 Check Shear Vmax = 990 Ib (Including Flexural Load Multiplier) Shear capacity not reduced for punchouts near ends of member Va = 5646 Ib >= Vmax Check Web Crippling Rmax = 990 Ib (Including Flexural Load Multiplier) Web Crippling capacity not reduced for punchouts near ends of member End Bearing Length = 1.00 in Ra = 1198 Ib >= Rmax, stiffeners not required 0.0566 in 0.0849 in 50.0 ksi 50.0 ksi 4.000 in SCAFCO Steel Stud Mfg. 2007 North American Specification [AISI S100] ASD DATE: 1/27/2019 MEZZ BEAM B2 SECTION DESIGNATION: 600S300-68 [50] (2) Boxed Input Properties: Web Height = Top Flange = Bottom Flange = Stiffening Lip = Punchout Width = 6.000 in 3.000 in 3.000 in 0.625 in 1.500 in Header/Beam Solver Design Data - Simple Span Header/Beam Span 12.00 ft Dead Load = 42.0 Ib/ft Live Load = 206.0 Ib/ft Check Flexure Input Flexural Bracing: None Cb = 1.14 lyy (Box) = 9.750 inA4 J (Box) = 14.858 in^4 Lu = 1582.7 in Mmax = 4464 Ft -Lb <= Ma = 7216 Ft -Lb Check Deflection Deflection Limit: L/360 Maximum Deflection = 0.374 in Design Thickness = Inside Corner Radius = Yield Point, Fy = Fy With Cold -Work, Fya = Punchout Length = Deflection Limit L/360 DL Multiplied by 1.00 for Strength Checks LL Multiplied by 1.00 for Strength Checks Deflection Ratio = L/385 Check Shear Vmax = 1488 Ib (Including Flexural Load Multiplier) Shear capacity not reduced for punchouts near ends of member Va = 10701 Ib >= Vmax Check Web Crippling Rmax = 1488 Ib (Including Flexural Load Multiplier) Web Crippling capacity not reduced for punchouts near ends of member End Bearing Length = 1.00 in Ra = 1829 Ib >= Rmax, stiffeners not required 0.0713 in 0.1070 in 50.0 ksi 50.0 ksi 4.000 in SCAFCO Steel Stud Mfg. 2007 North American Specification [AISI S100] ASD DATE: 1/27/2019 MEZZ LOAD BEARING WALLS SECTION DESIGNATION: 600S162-54 [50] Single Input Properties: Web Height = Top Flange = Bottom Flange = Stiffening Lip = Punchout Width = Wall Solver Design Data - Simple Span Wall Height 10.00 ft Lateral Pressure 5.00 psf Stud Spacing 16.0 in 6.000 in 1.625 in 1.625 in 0.500 in 1.500 in Check Flexure Load Multiplier for Flexural Strength = 1.00 Input Flexural Bracing: None Fe = 13.3 ksi Fy = 50.0 ksi Fc = 13.3 ksi Sc = 0.953 inA3 Sf = 0.953 inA3 Mmax = 83 Ft -Lb <= Ma = 631 Ft -Lb Design Thickness = Inside Corner Radius = Yield Point, Fy = Fy With Cold -Work, Fya = Punchout Length = Deflection Limit L/240 Axial Load 550 Ib Cb = 1.14 Check Deflection Deflection Limit: L/240 Load Multiplier for Deflection = 1.00 Maximum Deflection = 0.018 in 0.0566 in 0.0849 in 50.0 ksi 55.3 ksi 4.000 in Fe <= 0.56 Fy Mn = 1054 Ft -Lb Deflection Ratio = L/6751 Check Shear Vmax = 33 Ib (Including Flexural Load Multiplier) Shear capacity not reduced for punchouts near ends of member Va = 2823 Ib >= Vmax Check Web Crippling Rmax = 33 Ib (Including Flexural Load Multiplier) Web Crippling capacity not reduced for punchouts near ends of member End Bearing Length = 1.00 in Ra = 599 Ib >= Rmax, stiffeners not required Check Axial Interactions P = 550 Ib (Including Axial Load Multiplier) Axial Loads Multiplied by 1.00 for Interaction Checks Max unbraced length, KyLy and KtLt = 120.0 in Allowable Pure Axial Load, Pa = 1417 Ib : Axial Load Ratio, P/Pa = 0.388 K -phi for Distortional Buckling = 0 Ib*in/in Check Equation C5.2.1-1 Cmx = 1.00 Pcr = 57834 Ib Alpha = 0.982 Equation C5.2.1-1 = 0.523 Maximum Interaction = 0.523 <=1.0 Max KL/r = 211 Check Equation C5.2.1-2 Pao = 8521 Ib Equation C5.2.1-2 = 0.197 2001 North American Specification w/2004 Supplement ASD DATE: 1/31/2019 Half Pipe Track SECTION DESIGNATION: 362T150-43 Single INPUT PROPERTIES: Web Height = Top Flange = Bottom Flange = 3.786 in 1.500 in 1.500 in Ceiling Solver Design Data - Simple Span Joist Span 6.00 ft Joist Spacing 24.0 in Dead Load = 8.0 psf Live Load = 5.0 psf Steel Thickness = 0.0451 in Inside Corner Radius = 0.0712 in Yield Stress, Fy = 33.0 ksi Fy With Cold -Work, Fya = 33.0 ksi Deflection Limit L/360 DL Multiplied by 1.00 for Strength Checks LL Multiplied by 1.00 for Strength Checks Check Flexure Input Flexural Bracing: None Cb = 1.14 Me = 606 Ft -Lb My = 945 Ft -Lb Mc = 595 Ft -Lb Sc/Sf = 0.80 Mmax = 117 Ft -Lb <= Ma = 286 Ft -Lb Check Deflection Deflection Limit: L/360 Maximum Deflection = 0.045 in Deflection Ratio = L/1609 Check Shear Vmax = 78 Ib (Including Flexural Load Multiplier) Shear capacity not reduced for punchouts near ends of member Va = 1739 Ib >= Vmax Check Web Crippling Rmax = 78 Ib (Including Flexural Load Multiplier) Web Crippling capacity not reduced for punchouts near ends of member End Bearing Length = 1.00 in Ra = 208 Ib >= Rmax, stiffeners not required 0.56 My < Me < 2.78 My 2001 North American Specification w/2004 Supplement ASD DATE: 1/31/2019 Half Pipe - Box Beam SECTION DESIGNATION: 3625200-43 (2) Boxed INPUT PROPERTIES: Web Height = Top Flange = Bottom Flange = Stiffening Lip = Punchout Width = Header/Beam Solver Design Data Header/Beam Span 8.00 ft Dead Load = 100.0 Ib/ft Live Load = 30.0 psf 3.625 in 2.000 in 2.000 in 0.625 in 1.500 in - Simple Span Check Flexure Input Flexural Bracing: None Cb = 1.14 lyy (Box) = 1.699 inA4 J (Box) = 2.400 inA4 Lu = 1556.8 in Mmax = 1040 Ft -Lb <= Ma = 1405 Ft -Lb Check Deflection Deflection Limit: L/360 Maximum Deflection = 0.243 in Steel Thickness = 0.0451 in Inside Corner Radius = 0.0712 in Yield Stress, Fy = 33.0 ksi Fy With Cold -Work, Fya = 33.0 ksi Punchout Length = 4.000 in Deflection Limit L/360 DL Multiplied by 1.00 for Strength Checks LL Multiplied by 1.00 for Strength Checks Deflection Ratio = L/395 Check Shear Vmax = 520 Ib (Including Flexural Load Multiplier) Shear capacity not reduced for punchouts near ends of member Va = 3478 Ib >= Vmax Check Web Crippling Rmax = 520 Ib (Including Flexural Load Multiplier) Web Crippling capacity not reduced for punchouts near ends of member End Bearing Length = 1.00 in Ra = 553 Ib >= Rmax, stiffeners not required Screw Capacities Table Notes 1. Capacities based on AISI S100 Section E4. 2. When connecting materials of different steel thicknesses or tensile strengths, use the lowest values. Tabulated values assume two sheets of equal thickness are connected. 3. Capacities are based on Allowable Strength Design (ASD) and include safety factor of 3.0. 4. Where multiple fasteners are used, screws are assumed to have a center -to -center spacing of at least 3 times the nominal diameter (d). 5. Screws are assumed to have a center -of -screw to edge -of -steel dimension of at least 1.5 times the nominal diameter (d) of the screw. 6. Pull-out capacity is based on the lesser of pull-out capacity in sheet closest to screw tip or tension strength of screw. 7. Pull -over capacity is based on the lesser of pull -over capacity for sheet closest to screw header or tension strength of screw. 8. Values are for pure shear or tension loads. See AISI Section E4.5 for combined shear and pull -over. 9. Screw Shear (Pss), tension (Pts), diameter, and head diameter are from CFSEI Tech Note (F701-12). 10. Screw shear strength is the average value, and tension strength is the lowest value listed in CFSEI Tech Note (F701-12). 11. Higher values for screw strength (Pss, Pts), may be obtained by specifying screws from a specific manufacturer. Thickness Design (Mils) Thickness Fy Yield (ksi) Fu Tensile (ksi) Allowable #6 Screw (Pss = 643 lbs, Pts = 419 lbs) 0.138" dia, 0.272" Head Screw Connection #8 Screw (Pss= 1278 lbs, Pts = 586 lbs) 0.164" dia, 0.272' Head Capacity (lbs) #10 Screw (Pss= 1644 lbs, Pts =1158 lbs) 0.190" dia, 0.34V Head #12 Screw (Pss= 2330 lbs, Pts = 2325 lbs) 0.21V dia, 0.340" Head Y." Screw (Pss= 3048 lbs, Pts = 3201 lbs) 0.250" dia, 0.409' Head Fy Fu Fillet Shear Pull -Out Pull -Over Shear Pull -Out Pull -Over Shear Pull -Out Pull -Over Shear Pull -Out Pull -Over Shear Pull -Out Pull -Over 18 0.0188 33 33 44 24 84 48 29 84 52 33 105 55 38 105 60 44 127 27 0.0283 33 33 82 37 127 89 43 127 96 50 159 102 57 159 110 66 191 30 0.0312 33 33 95 40 140 103 48 140 111 55 175 118 63 175 127 73 211 33 0.0346 33 45 151 61 140 164 72 195 177 84 265 188 95 265 203 110 318 43 0.0451 33 45 214 79 140 244 94 195 263 109 345 280 124 345 302 144 415 54 0.0566 33 45 214 100 140 344 118 195 370 137 386 394 156 433 424 180 521 68 0.0713 33 45 214 125 140 426 149 195 523 173 386 557 196 545 600 227 656 97 0.1017 33 45 214 140 140 426 195 195 548 246 386 777 280 775 1,016 324 936 118 0.1242 33 45 214 140 140 426 195 195 548 301 386 777 342 775 1,016 396 1,067 54 0.0566 50 65 214 140 140 426 171 195 534 198 386 569 225 625 613 261 752 68 0.0713 50 65 214 140 140 426 195 195 548 249 386 777 284 775 866 328 948 97 0.1017 50 65 214 140 140 426 195 195 548 356 386 777 405 775 1,016 468 1,067 118 0.1242 50 65 214 140 140 426 195 195 548 386 386 777 494 775 1,016 572 1,067 Weld Capacities Table Notes 1. Capacities based on the AISI S100 Specification Sections E2.4 for fillet welds and E2.5 for flare groove welds. 2. When connecting materials of different steel thicknesses or tensile strengths, use the lowest values. 3. Capacities are based on Allowable Strength Design (ASD). 4. Weld capacities are based on E60 electrodes. For material thinner than 68 mil, 0.030" to 0.035" diameter wire electrodes may provide best results. 5. Longitudinal capacity is considered to be loading in the direction of the length of the weld. 6. Transverse capacity is loading in perpendicular direction of the length of the weld. 7. For flare groove welds, the effective throat of weld is conservatively assumed to be less than 2t. 8. For longitudinal fillet welds, a minimum value of EQ E2.4-1, E2.4-2, and E2.4-4 was used. 9. For transverse fillet welds, a minimum value of EQ E2.4-3 and E2.4-4 was used. 10. For longitudinal flare groove welds, a minimum value of EQ E2.5-2 and E2.5-3 was used. We/d capacity for materia/ thickness greater than 0.10' requires engineering judgment to determine /eg of we/ds, WI and W2. 7n Allowable Weld Capacity (lbs / irlr Thickness Design Fy Fu Fillet Welds Flare Groove Welds (Mils) ThicknesssignYield (ksi) Tensile (ksi) Longitudinal Transverse Longitudinal Transverse 43 0.0451 33 45 499 864 544 663 54 0.0566 33 45 626 1084 682 832 68 0.0713 33 45 789 1365 859 1048 97 0.1017 33 45 1125 1269 -' -' 54 0.0566 50 65 905 1566 985 1202 68 0.0713 50 65 1140 1972 1241 1514 97 0.1017 50 65 1269 1269 -' -' We/d capacity for materia/ thickness greater than 0.10' requires engineering judgment to determine /eg of we/ds, WI and W2. 7n Wall Footing Description : TH NAIL Code References Calculations per ACI 318-14, IBC 2015, CBC 2016, ASCE 7-10 Load Combinations Used : ASCE 7-10 General Information Material Properties fc : Concrete 28 day strength fy : Rebar Yield Ec : Concrete Elastic Modulus Concrete Density cp Values Flexure Shear Analysis Settings Min Steel % Bending Reinf. Min Allow % Temp Reinf. Min. Overturning Safety Factor Min. Sliding Safety Factor AutoCalc Footing Weight as DL Dimensions 2.50 ksi 60.0 ksi = 2,850.0 ksi 145.0 pcf = 0.90 0.750 = 0.00180 1.0:1 = 1.0:1 Yes Soil Design Values Allowable Soil Bearing Increase Bearing By Footing Weight Soil Passive Resistance (for Sliding) Soil/Concrete Friction Coeff. Increases based on footing Depth Reference Depth below Surface Allow. Pressure Increase per foot of depth when base footing is below Increases based on footing Width Allow, Pressure Increase per foot of width when footing is wider than = 1.50 ksf = No = 250.0 pcf = 0.30 0.0 ft 0.0 ksf = 0.0 ft = 0.0 ksf 0.0 ft Adjusted Allowable Bearing Pressure = 1.50 ksf Reinforcing Footing Width Wall Thickness Wall center offset from center of footing 2 ft Footing Thickness - 12.0 in Bars along X -X Axis 6.0 in Rebar Centerline to Edge of Concrete... Bar spacing at Bottom of footing = 3.0 in Reinforcing Bar Size 0 in 12.00 # 5 6` Applied Loads 2'10. -r P : Column Load OB : Overburden V -x M-zz Vx applied D Lr L S W E H 0.4 0.0 0.750 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 k 0.0 ksf 0.0 0.0 0.0 0.0 0.0 in above top of footing 0.0 0.0 0.0 0.0 0.0 k 0.0 0.0 0.0 0.0 0.0 k -ft Wall Footing Description : TH NAIL DESIGN SUMMARY Factor of Safety Item Design OK Applied Capacity Governing Load Combination PASS PASS PASS PASS PASS PASS PASS PASS n/a n/a n/a Utilization Ratio 0.480 0.02367 0.007249 n/a 0.0 Detailed Results Overturning - Z -Z Sliding - X -X Uplift Item Soil Bearing Z Flexure (+X) Z Flexure (-X) 1 -way Shear (+X) 1 -way Shear (-X) 0.0 k -ft 0.0 k 0.0 k Applied 0.720 ksf 0.2852 k -ft 0.08733 k -ft 0.0 psi 0.0 psi 0.0 k -ft 0.0 k 0.0 k Capacity 1.50 ksf 12.046 k -ft 12.046 k -ft 75.0 psi 0.0 psi No Overturning No Sliding No Uplift Governing Load Combination +D+L +1.20D+1.60L +0.90D n/a n/a Soil Bearing Rotation Axis & Load Combination... D Only +D+L +D+0.750L +0.60D Overturning Stability Actual Soil Bearing Stress Actual 1 Allowable Gross Allowable Xecc -X +X Ratio 1.50 ksf 1.50 ksf 1.50 ksf 1.50 ksf 0.O in 0.O in 0.O in 0.O in 0.3450 ksf 0.720 ksf 0.6263 ksf 0.2070 ksf 0.3450 ksf 0.720 ksf 0.6263 ksf 0.2070 ksf 0.230 0.480 0.418 0.138 Units : k -ft Rotation Axis & Load Combination... Footing Has NO Overturning Sliding Stability Overturning Moment Resisting Moment Stability Ratio Status Force Application Axis Load Combination... Footing Has NO Sliding Footing Flexure Sliding Force Resisting Force Sliding SafetyRatio Status Flexure Axis & Load Combination Mu Which Tension @ Bot. k -ft Side ? or Top ? As Req'd inA2 Gvrn. As Actual As in"2 in^2 Phi*Mn k -ft Status , +1,40D , +1,40D , +1.20D+1.60L +1.20D+1.60L +1.20D+0.50L +1.20D+0.50L , +1.20D , +1.20D +0.90D +0.90D One Way Shear 0.1358 0.1358 0.2852 0.2852 0.1692 0.1692 0.1164 0.1164 0.08733 0.08733 -X Bottom +X Bottom - X Bottom +X Bottom -X Bottom +X Bottom - X Bottom +X Bottom -X Bottom +X Bottom 0.2592 0.2592 0.2592 0.2592 0.2592 0.2592 0.2592 0,2592 0.2592 0.2592 Min Temp % Min Temp % Min Temp% Min Temp % Min Temp % Min Temp % Min Temp % Min Temp % Min Temp % Min Temp % 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 0.31 12.046 12.046 12.046 12.046 12.046 12.046 12.046 12.046 12.046 12,046 Units : k OK OK OK OK OK OK OK OK OK OK Load Combination... +1.40D +1.20D+1.60L +1.20D+0.50L +1.20D +0.90D Vu @ -X Vu @ +X Opsi Oosi 0 psi 0 psi 0 psi 0 psi 0 psi 0 psi 0psi 0msi Vu Max Phi Vn Vu I Phi*Vn 0 psi 75 psi 0 0 psi 75 psi 0 0 psi 75 psi 0 0 psi 75 psi 0 0 psi 75 psi 0 Status OK OK OK OK OK CEILING JOIST SCAFCO Steel Stud Mfg. 2007 North American Specification [AISI S100] ASD DATE: 3/16/2019 SECTION DESIGNATION: 362S162-43 [33] Single Input Properties: Web Height = Top Flange = Bottom Flange = Stiffening Lip = Punchout Width = 3.625 in 1.625 in 1.625 in 0.500 in 1.500 in Ceiling Solver Design Data - Simple Span Joist Span 6.00 ft Joist Spacing 24.0 in Dead Load = 5.0 psf Wind Load = 10.0 psf Design Thickness = Inside Corner Radius = Yield Point, Fy = Fy With Cold -Work, Fya = Punchout Length = Deflection Limit L/360 DL Multiplied by 1.00 for Strength Checks WL Multiplied by 1.00 for Strength Checks WL Multiplied by 1.00 for Deflection Checks Check Flexure Input Flexural Bracing: None Cb = 1.14 Fe = 37.8 ksi Fy = 33.0 ksi Fc = 27.8 ksi Sc = 0.374 inA3 Sf = 0.392 inA3 Mmax = 135 Ft -Lb <= Ma = 519 Ft -Lb Check Deflection Deflection Limit: L/360 Maximum Deflection = 0.042 in 0.0451 in 0.0712 in 33.0 ksi 33.0 ksi 4.000 in 0.56 Fy < Fe < 2.78 Fy Mn = 867 Ft -Lb Deflection Ratio = L/1723 Check Shear Vmax = 90 Ib (Including Flexural Load Multiplier) Shear capacity not reduced for punchouts near ends of member Va = 1739 Ib >= Vmax Check Web Crippling Rmax = 90 Ib (Including Flexural Load Multiplier) Web Crippling capacity not reduced for punchouts near ends of member End Bearing Length = 1.00 in Ra = 277 Ib >= Rmax, stiffeners not required V kv ✓- 2007 North American Specification [AISI S100] ASD DATE: 3/12/2019 SECTION DESIGNATION: 600S162-68 [50] Single Input Properties: Web Height = Top Flange = Bottom Flange = Stiffening Lip = Punchout Width = Floor Solver Design Data - Simple Span Joist Span 10.00 ft Dead Load = 15.0 psf Live Load = 75.0 psf 6.000 in 1.625 in 1.625 in 0.500 in 1.500 in Design Thickness = Inside Corner Radius = Yield Point, Fy = Fy With Cold -Work, Fya = Punchout Length = Joist Spacing 16.0 in Check Flexure Mmax = 1500 Ft -Lb <= Ma = 3289 Ft -Lb & Ma(distortional) = 2975 Ft -Lb K -phi for Distortional Buckling*in/in Check Deflection Total Load Defl Limit: L/240 Total Load Defl. = 0.260 in Live Load Defl Limit: L/360 Live Load Defl. = 0.216 in Total Load Defl. Ratio = L/462 Live Load Defl. Ratio = L/555 Check Web Crippling Web Crippling capacity not reduced for punchouts near ends of member Rmax =.600 -Ib End Bear g Length = 1.00 in Ra = 914 Ib >= Rmax, stiffeners not required Check Shear Vmax = 600 Ib Shear capacity not reduced for punchouts near ends of member Va = 5350 Ib >= Vmax x7 &a',,on iJ„ct.i E c'r �yr� 4'a 6501/4. � Q.�t )1C' -t -1 3 � a -+-(246 fvN Z.t 110 Z 0.0713 in 0.1070 in 50.0 ksi 56.6 ksi 4.000 in s� + fI 4 `'fit - 4` ' z- PI tt 3/18/2019 ATC Hazards by Location OTCHazards by Location Search Information Address: 12750 Southcenter Pkwy, Tukwila, WA 98188, USA Coordinates: 47.46109060000001, -122.2623021 Elevation: 35 ft est Timestamp: 2019-03-19T05:32:45.111 Z Hazard Type: Seismic Reference ASCE7-16 Document: Shelton h q' Goggle Mapi Report a map error Risk Category: II Site Class: C MCER Horizontal Response Spectrum Design Horizontal Response Spectrum Sa(g) 1.50 1.00 0.50 0.00 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 Basic Parameters Name Ss Si SMS SM1 SDS SD1 Sa(g) 1.00 0.80 0.60 0.40 0.20 0.00 Period (s) 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 Period (s) Value Description 1.47 MCER ground motion (period=0.2s) 0.5 MCER ground motion (period=1.0s) 1.764 Site -modified spectral acceleration value 0.75 Site -modified spectral acceleration value 1.176 Numeric seismic design value at 0.2s SA 0.5 Numeric seismic design value at 1.0s SA vAdditional Information Name Value Description SDC D Seismic design category Fa 1.2 Site amplification factor at 0.2s F„ 1.5 Site amplification factor at 1.0s https://hazards.atcouncil.org/#/seismic?Iat=47.46109060000001 &Ing= -122.2623021 &address=12750%20Southcenter%20Pkwv%2C%20Tukwila%2C... 1/2 3/18/2019 ATC Hazards by Location CRs 0.9 Coefficient of risk (0.2s) CR1 0.895 Coefficient of risk (1.0s) PGA 0.625 MCEG peak ground acceleration FPGA 1.2 Site amplification factor at PGA PGAM 0.751 Site modified peak ground acceleration TL 6 Long-iperiod transition period (s) SsRT 1.47 Probabilistic risk -targeted ground motion (0.2s) SsUH 1.633 Factored uniform -hazard spectral acceleration (2% probability of exceedance in 50 years) SsD 4.3 Factored deterministic acceleration value (0.2s) Si RT 0.5 Probabilistic risk -targeted ground motion (1.0s) S1UH 0.558 Factored uniform -hazard spectral acceleration (2% probability of exceedance in 50 years) S1 D 1.504 Factored deterministic acceleration value (1.0s) PGAd 1.359 Factored deterministic acceleration value (PGA) The results indicated here DO NOT reflect any state or local amendments to the values or any delineation lines made during the building code adoption process. Users should confirm any output obtained from this tool with the local Authority Having Jurisdiction before proceeding with design. Disclaimer Hazard loads are provided by the U.S. Geological Survey Seismic Design Web Services. While the information presented on this website is believed to be correct, ATC and its sponsors and contributors assume no responsibility or liability for its accuracy. The material presented in the report should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. ATC does not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the report provided by this website. Users of the information from this website assume all liability arising from such use. Use of the output of this website does not imply approval by the goveming building code bodies responsible for building code approval and interpretation for the building site described by latitude/longitude location in the report. https://hazards.atcouncil.org/#/seism ic?Iat=47.46109060000001 &Ing=-122.26230218address=12750%20Southcenter%20Pkwy%2C%20Tukwila%2C... 2/2 Spectral Accelaration (Short Period), SDs Component Amplification Factor, ap Response Modification Factor, Rp Component Importance Factor, Ip Component Operation Weight, Wp Vertically Cantilevered System Component Height, z Average Roof Height, h Fp _ Fp (Max) = 1.6 SDS: Fp (Max) = 1.6 SDsIpWp: Fp (Min) = 0.3SDs: Fp (Min) = 0.3SDsIpWp: 1.176 1.00 2.50 1.00 870 lbs N 16.00 ft 23.00 ft z h = 0.70 z 1+2h = 2.39 0.4apSDSz (1+2—) RPI/p 0.4a Spsz P W P(1+2 RPh hp Concurrent Vertical Seismic Force, +-0.2SDsWp: Seismic Design Force, Fp: = 0.45 use (4) #8 screws total to resist seismic force; Ta = 4 x 72#= 288 # > Fp, O.k. ASCE 7-10 Table 13.5-1 or 13.6-1 ASCE 7-10 Table 13.5-1 or 13.6-2 ASCE 7-10 13.1.3 391.5 lbs ASCE 7-10, 13.3-1 1.88 1637.0 lbs ASCE 7-10 Eq. 13.3-2 0.35 306.9 lbs ASCE 7-10 Eq. 13.3-3 +- lbs 391.5 lbs 274.0 lbs ASD . ,. a7//2_. /2-0(7 Mavv,1 e_ i 5 A cup t tn ,v,. 4k € -"V1 a:‘S te. OLA b 1t3-o3Get) a by v tr&J- sem\ Al k- (-Lc 6,...... 1 0 /)..si Avkt. 13 0.6k.,-. Q....A.. ctAre_ -44a 4141,il\, tiootke,l, rvx _1 M2 -v) rY c_vy_ 5 C1k.a,w . frc t ,sem L G (0 c7 0 _. N(unYe� I -4 C ECTION LT Catch Design Studio 1405 Boylston Ave Seattle, WA 98122 P# 206-322-4323 TH NAIL SALON -�u REVISION NOL.L Building Department Correction Letter Response #1: I February 27th 2019 t,3.h4 17250 Southcenter PKWY Suite# 140 Tukwila, WA 98188 City of Tukwila Department of Community Development February 27, 2019 TOMMY NGUYEN 11856 9TH AVE SW SEATTLE, WA 98146 RECEIVED CITY OF TUKWILA MAR 2 0 2019 PERMIT CENTER Correction Letter # 1 to Rev #1 DEVELOPMENT Permit Application Number D18-0364 TH NAIL BAR & SPA -17250 SOUTHCENTER PKWY - SUITE 140 Tukwila, WA 98188 Dear TOMMY NGUYEN, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - R DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x17 to a preferably maximum size of 24x36; all sheets shall be the same size; larger sizes may be negotiable. "New revised" plan sheets shall be the same size sheets as those previously submitted.) "STAMP AND SIGNATURES" (If applicable) For Engineers: "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document t at contains specifications other than that of an engineering or land surveys . "fure, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient.(WAC 196-23-010 & 196-23-020). Architects: "date" only not required (WAC 308-12-081). (BUILDING REVIEW NOTES) 1:. Prodicltif a revised cover sheet index to show all plan sheets including the additional revision sheets. Provide a complete new set of plans with all sheets indicated in the index. • Updated Index Drawings. 2. On the cover sheet show the occupant load and specify a change of use from M to B occupancy. • - Actded`occupancy load and change of use from M to B occupancy. 3. Detail "E" on sheet A3 indicates the ceiling attached to a concrete structure above: Revise detail to specify and show consistency with engineering where the ceiling shall attach to roof framing and specify the spacing and type of the ceiling support an'chors. • Removed detail E, A3. See ceiling detail on structure page S1, S2, S3. 4. The wall types Legend on sheet A3 appear to conflict with the specified walls i.e. wall type 1 with GWB on both sides is shown in the mezzanine against the exterior wall. Other walls on the Ceiling framing plan indicate interior room walls with GWB on one side. Please clarify. • Changed wall type 1, 3, and 5, from 4" metal studs GWB 1 one side - to 6" metal studs GWB both sides. To follow structural drawings. 5. Sheet A6 detail "B" indicates Top View assuming it is an elevation view. Please clarify. • Changed from "Top View" to "Detail B". 6. Provide special inspections in a matrix table shown on the engineer's plan sheet for the engineered structural framing. • See S2 7. Engineers stamp shall have the "Date" of signature on the engineer's stamp. See General Note above. • See S pages 8. Plumbing, Mechanical and Electrical plans shall reflect the new changes. • Updated 9. Storage racks over 5'9" shall require a separate permit. Rack storage over 8' shall require engineering. Specify manufacturer type and size of storage racks in the mezzanine. • Added note and resized storage racks. • • • 10. Revise stair detail to show the stair tread depth 11 inches between foremost projection of adjacent treads. Adjust stairway accordingly. (IBC 1011.5.2) • Added note and show the stair tread depth 11 inch. 11. The stair details on sheet A5 has two separate details as B3. The top B3 detail for stair steel framing is not very clear describing the framing of the stairs. Clarify the stair framing and only show one type of stairway construction detail • Removed all B details on A5. Details 1,2, and 3 added to follow engineer's drawing. 12. Clarify the height of the wall #4 in the stairway (full or partial height with height dimensions). • Removed wall type 4 Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. Sincerely, Jazzel Salm- Permit Technician File No. D18-0364 - 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 - hniW i 1 COORD G0A4 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0364 DATE: 03/20/19 PROJECT NAME: TH NAIL BAR & SPA SITE ADDRESS: 17250 SOUTHCENTER PKWY UNIT 40 Original Plan Submittal X Response to Correction Letter # 1 Revision # 1 before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator • PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 03/21/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04/18/19 Approved ❑ Approved with Conditions ❑ Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Onl CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW ❑ Staff Initials: 12/18/2013 �'ERMIT COORD COPY • PLAN REVIEW/ROUTING SLIP PERMITNUMBER: D18-0364 DATE: 02/06/19 PROJECT NAME: TH NAIL BAR & SPA SITE ADDRESS 17250 SOUTHCENTER PKWY - SUITE 140 Original Plan Submittal X Revision # 1 before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: g3 �i�2 itC1 Building Division Pubc Worlls PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) Fire Prevention Structural 14 IV 2,2:2A Planning Division ❑ Permit Coordinator II DATE: 02/07/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03/07/19 Approved ❑ Approved with Conditions ❑ Corrections Required XJ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use On CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire ❑ Ping ❑ PW 0 Staff Initials: V,) 12/18/2013 *PERMIT COORD COPY « PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0364 DATE: 11/14/18 PROJECT NAME: NU SPA AND NAIL SALON SITE ADDRESS: 17250 SOUTHCENTER PKWY X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: kW 11--«'—r0 Building Division 111 JJS AM" Public Works to Aug. Fire Prevention Structural htc,yB ,mac Planning Division 111 ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 11/15/18 Structural Review Required REVIEWER'S INITIALS: DATE: El APPROVALS OR CORRECTIONS: DUE DATE: 12/13/18 Approved ❑ Approved with Conditions ❑ Corrections Required Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use On y 3 CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 3 -go- 1 -1 Plan Check/Permit Number: D18-0364 O Response to Incomplete Letter # ® Response to Correction Letter # _1_ O Revision # 1 before Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: TH NAIL BAR & SPA Project Address: 17250 SOUTHCENTER PKWY UNIT 140 Contact Person:it) 05 WW1 1\) Summary of Revision: Phone Number: 206 24.0 c650 5EE A -7711c10 1 -4577 - RECEIVED MAR 2; 0 2u19 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision includin ate of revis' Received at the City of Tukwila Permit Center by: IN— Entered in TRAKiT on-- W:\Permit Center (Rachelle)\Forms\Pennit Center Documents (Word)\Revision Submittal Form.doc Revised: August 2015 Date: 2/5/201q • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: 1715-03(04 ❑ Response to Incomplete Letter # ❑ Response to Correcti Letter # ® Revision # 1bPermit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: T{4 NAIL Project Address: 0 Soathceviter Tarkwa i Takwila, Wfl 615155 ,qj-{— ' /4 Phone Number: 2134-322432-3 Contact Person: Nos Narim Summary of Revision: Approved permit VIS -03(p4 ? eM tT ArrgoVeP MR/1(1- : Pte --off- re4c. ROVISIoN: 4f p(N G- ?4241V/,V S?oi ARCA' 4 9 STi2 KGTL1eV efiavvr i\A e t Ii -a (= Tv EIVED CITY OF TUKWILA FEB 062019 PERMIT CENTER Sheet Number(s): CS1, - 7, T1 - 3, S1, avid SZ "Cloud" or highlight all areas of revision including d Received at the City of Tukwila Permit Center by: —Entered in TRAKiT on �� '( W:\Permit Centro\Templates\For s\Revision Submittal Formdoc Revised: August 2015 Home Espanol Contact Safety & Health Claims & Insurance C:iWashington State Department of Labor & Industries Search L&I S ARCHi A-ZIndex Help Myi.&l Workplace Rights Trades & Licensing CHAU CONSTRUCTION LLC Owner or tradesperson DINH, NATALIE Principals DINH, NATALIE, DIRECTOR WA UBI No. 603 597 789 5028 HIGHLAND DR SE AUBURN, WA 98092 206-304-7977 KING County Business type Limited Liability Company Certifications & Endorsements OMWBE Certifications No active certifications exist for this business. Apprentice Training Agent Not allowed to have apprentices. License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. CHAUCCL844JF Effective — expiration 04/06/2016— 04/10/2020 Bond Wesco Insurance Co Bond account no. 46WB074769 $12,000.00 Received by L&I Effective date 04106/2016 04105/2016 Expiration date Until Canceled Insurance Security National Insurance $1,000,000.00 Policy no. NAI15332203 Received by L&I Effective date 04/04/2019 04/05/2019 Expiration date 04/05/2020 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings Help us improve No lawsuits against the bond or savings acc0 during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. 0 License Violations No license violations during the previous 6 year period. Workers' comp Public Works Requirements Workplace safety and health Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve • Home Espanol Contact. Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries • Search L&I A -Z Index Help hty t.&I Workplace Rights Trades & Licensing John Hunt Construction LLC Owner or tradesperson Hunt, John F Principals Hunt, John F, PARTNER/MEMBER WA UBI No. 602 775 512 3114 ne 82 st SEATTLE, WA 98115 206-226-7122 KING County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. JOHNHHC92004 Effective — expiration 11/2412008— 03/27/2019 Bond Wesco Insurance Co Bond account no. 46W B030022 $12,000.00 Received by L&I Effective date 07/17/2013 0613012013 Expiration date Until Canceled Bond history Insurance Capitol Specialty Inc Corp Policy no. CS19000129-01 $1,000,000.00 Received by L&I Effective date 01/11/2019 01/10/2019 Expiration date 01110/2020 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations Infraction no. Help us improve