Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D18-0398 - HIRSI RESIDENCE - REROOF, INSULATION, KITCHEN REMODELING ETC
HIRSI RESIDENCE 3214 S 142 PL EXPIRED 10/15/19 018-0398 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov DEVELOPMENT PERMIT 9415000030 Permit Number: 3214 S 142ND PL HIRSI RESIDENCE Issue Date: Permit Expires On: D18-0398 3/5/2019 9/1/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: ANDERSON ANDREW J 6434 WINONA CT, ARVADA, WA, 80003 YOUNG KIM 13031 NE TENTH ST, BELLEVUE, WA, 98005 CH REMODELING AND HANDYMAN 15405 DES MOINES MEMORIAL DR A102, BURIEN, WA, 98148 CH REMRH840MF Lender: Name: ABDIRAHIM HIRSI Address: 3214 S 142ND PL, TUKWILA, WA, 98188 Phone: (206) 355-9686 Phone: Expiration Date: DESCRIPTION OF WORK: RE -ROOFING, INSULATION IN THE ATTIC, EXTERIOR WALL, CRAWL SPACE, BATHROOM, KITCHEN REMODELING. Project Valuation: $35,000.00 Type of Fire Protection: Sprinklers: Fire Alarm: YES Type of Construction: Electrical Service Provided by: TUKWILA Fees Collected: $1,312.97 Occupancy per IBC: R-3 Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: 3-E-161 I hearby certify that I have read and examined this permit and know the same to be true and correct. AH provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signatur Print Name: Pazvizi-rw-t ()Nur This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: A Certificate of Occupancy shall be issued for this building upon final inspection approval by Tukwila building inspector. 6: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 7: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one-third and lower one-third of the water heater's vertical dimension. A minimum distance of 4 -inches shall be maintained above the controls with the strapping. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 12: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments 14: Application of roof coverings with the use of an open -flame device or use of a propane fueled asphalt kettle requires a separate permit from the Tukwila Fire Marshals Office located at 6300 Southcenter BI Suite 209 Tukwila, WA 98188. Telephone (206) 575-4407. There shall be not less than one multi-purpose portable fire extinguisher with a minimum 2-A20-B:C rating and a charged, minimum diameter 5/8 diameter water line(hose) on the roof being covered or repaired. (IFC 105.6.24, 3504.2.5, 3504.2.6) 13: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 15: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 16: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0409 FRAMING 0606 GLAZING 0608 PIPE INSULATION 0603 ROOF/CEILING INSUL 0602 SLAB/FLOOR INSUL 0412 UNDERFLOOR FRAMING 0601 WALL INSULATION 0413 WALL SHEATHING/SHEAR 0 0 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. T 1 - 0 Project No. t PP P Date Application Accepted: t ` 2.-i1 ) — Date Application Expires: l(I,` " I " 1 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 941500-0030 Site Address: 3214 so. 142nd pl., Tukwila, WA 98168 Suite Number: Floor: ground Tenant Name: Abdirahim Hirsi PROPERTY OWNER Name: Young Kim Name: Abdirahim Hirsi City: Bellevue State: WA Zip: 98005 Address: 3214 so. 142nd pl., Email: yk98005@yahoo.com City: Tukwila, State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Young Kim Address: 13031 NE 10th St City: Bellevue State: WA Zip: 98005 Phone: (206) 355-9686 Fax: Email: yk98005@yahoo.com GENERAL CONTRACTOR INFORMATION Company Name: Address: Company Name: Architect Name: Young Kim City: State: City: Bellevue State: WA Zip: Phone: Fax: Email: yk98005@yahoo.com State: Contr Reg No.: Phone: Exp Date: Tukwila Business License No.: H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.doca Revised: August 2011 bh New Tenant: ❑ Yes ..No ARCHITECT OF RECORD Name: Company Name: _ Company Name: Architect Name: Young Kim Address: 13031 NE 10th St City: City: Bellevue State: WA Zip: 98005 Phone: (206) 355-9686 Fax: Email: yk98005@yahoo.com State: ENGINEER OF RECORD Name: 'tpp L`t- i 0 (yNE-P._ Company Name: Address: Engineer Name: City: State: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: 'tpp L`t- i 0 (yNE-P._ Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 35,000 Existing Building Valuation: $ 280,000 Describe the scope of work (please provide detailed information): Re -roofing, insulation in the attic, exterior wall, crawl space, bathroom, kitchen remodeling Will there be new rack storage? ❑ Yes m.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) 1,368 *For an Accessory dwelling, provide the following: Lot Area (sq fl): 8,400 Floor area of principal dwelling: 1,368 Floor area of accessory dwelling: 0 *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 3 Compact: Handicap: Will there be a change in use? ❑ Yes m No If"yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers m Automatic Fire Alarm ❑ None 0 Other (specify) smoke detector Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If `yes', attach list ofmaterialsand storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 1 `' 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC lat Floor 1,368 567 V -B R3 2"d Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) 1,368 *For an Accessory dwelling, provide the following: Lot Area (sq fl): 8,400 Floor area of principal dwelling: 1,368 Floor area of accessory dwelling: 0 *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 3 Compact: Handicap: Will there be a change in use? ❑ Yes m No If"yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers m Automatic Fire Alarm ❑ None 0 Other (specify) smoke detector Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If `yes', attach list ofmaterialsand storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 1 `' 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFORMATION ,,t4 yah 6o'%*10191,ni er - 50bliib i6 16j. eloih iw iho+i 6433:7-..0179, ; Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ...Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate %}?_<... Valley View 0... Sewer Availability Provided ❑ .. Highline 0 .. Renton ❑ .. Renton ❑ .. Seattle Septic System: 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑. ❑. ❑. ❑. ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage . Abandon Septic Tank . Curb Cut . Pavement Cut . Looped Fire Line ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public ❑ ❑ ...Water Main Extension Public ❑ 11 11 11 11 ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding wo # wo # WO # ❑...Deduct Water Meter Size Private ❑ Private ❑ 11 FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 3 of 4 !ERMIT°APPLICATIONNOTES - .�k iPs lii�l ia` -sx ad,4W Vf'`" Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: 5U �.� Date: 12/24/2018 Print Name: Young Kim Day Telephone: (206) 355-9686 Mailing Address: 13031 NE 10th st. Bellevue WA 98005 City State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 4 of 4 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $813.44 D18-0398 Address: 3214 S 142ND PL Apn: 9415000030 $813.44 DEVELOPMENT $775.01 PERMIT FEE R000.322.100.00.00 0.00 $768.51 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $6.50 TECHNOLOGY FEE $38.43 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R17085 R000.322.900.04.00 0.00 $38.43 $813.44 Date Paid: Tuesday, March 05, 2019 Paid By: ABDIRAHIM HIRSI Pay Method: CASH Printed: Tuesday, March 05, 2019 3:18 PM 1 of 1 SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $499.53 D18-0398 Address: 3214 S 142ND PL Apn: 9415000030 $499.53 DEVELOPMENT $499.53 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R16221 R000.345.830.00.00 0.00 $499.53 $499.53 Date Paid: Monday, December 24, 2018 Paid By: YOUNG T KIM Pay Method: CHECK 1069 Printed: Monday, December 24, 2018 10:48 AM 1 of 1 a.. SYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 PERMIT NO. Project: A Type of Inpection: Address: 3V 4 S I 4Z14P Date Called: Special Instructions: Date Wanted: 4-16- r f . p. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: c.9‘5 -L2 Wed Wwzr0 (-0^( Qv( �� }rj otwt, \N61)17 4-4411 i Vs •ern,, ", cV,.� 2biltA-cAck r� 1. 0,r eco tt *O.Ae(a, Inspector: Date: 10 n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 o53 Project: 1 11 145 Type of Inspecti n: VF l=<<-,4ar_. Address: 324 $ 114/e° PL. Date Called: Special Instructions: Date Wanted: 3i9 a.m. Requester: Phone No: Approved per applicable codes. rrections required prior to approval. COMMENTS: Liv 4 IN -'i d ifibd ti,mot ?lam CA/LA O6 PACO Y,.►WY2F4A4 Inspector: Date: 77 C REINSPECTION FE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1l5C7 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ply- D39g 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: , II 0 1 gs?cierf T ofInspection: ois Werr1/4, Address:/24 Date Called: Special�Instructions: A-64 - / / Ks T3 I z r 1 o� 1 P Date Wanted: ‘Pi-ttr- -42 a 2-0! Rrle ues;er:i R ., BL a-tf j Phone No: w/o -S57r- 2389' Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date:,oy REINSPECTION FEE REQUIRED. Prior to next inspection. fee mast be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 4,0 CORRECTION LTR# 1.3 min EVIEVVED-FIOR •0 ,E COMPLIANCE 4PPROVED tAR 012019 14. . of Tukwila DIVISION t RECEIVED TV OF TUKWILA FEB 22 2019 \ tin CENTIEF'ti 03\ Yahoclvfail -, Re: Permit PW19-0007 - Roof Structure: No Change https://mail.yahoo.com/d/search/keyword=lee%20sipe/message... Re: Permit PW19-0007 - Roof Structure: No Change From: Young Kim (yk98005@yahoo.com) To: Laurie.Werle@TukwilaWA.gov Date: Tuesday, February 19, 2019, 8:32 PM PST Thank you Laurie. On Tuesday, February 19, 2019, 10:56:53 AM PST, Laurie Werle <Laurie.Werle@TukwilaWA.gov> wrote: Permit PW19-0007 is for backfilling. It has nothing to do with roof framing. I'm assuming this has to do I with permit D18-0398. Laurie Werle Permit Technician City of Tukwila Public Works 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Phone: (206)433-7184 Fax: (206)431-3665 Iaurie.werle@tukwilawa.gov / www.tukwilawa.gov From: Young Kim <yk98005@yahoo.com> Sent: Monday, February 18, 2019 12:36 PM To: Lee Sipe <Lee.Sipe@TukwilaWA.gov>; Lauri Dunning <Lauri.Dunning@TukwilaWA.gov>; Laurie Werle <Laurie.Werle@TukwilaWA.gov> Subject: Fw: Permit PW19-0007 - Roof Structure: No Change Hi Lee, Thanks for your review comments. RECEIVED CITY OF TUKWILA FEB 2 2 2019 PERMIT CENTER Please refer to below responses and attached pdf files. As the photo showed and verified by me, there is no roof framing and truss changed. The fresh plywood shows the opening for chimney area. 1 of 3 2/22/2019, 8:33 AM Yahoo Mail Re: Permit PW19-0007 - Roof Structure: No Change https://mail.yahoo.com/d/search/keyword=lee%20sipe/message... Laurie, if you can, please have a chance to verify the roof structure at site when inspections are made. Thank you, Young Kim, 206) 355-9686 Forwarded Message From: Lee Sipe <Lee.SipeTukwilaWA.gov> To: Young Kim <yk98005(yahoo.com> Sent: Tuesday, February 12, 2019, 3:47:41 PM PST Subject: RE: Permit PW19-0007 Young Kim Notice the comments in red, that are required. 1. R106.1.1: Info. on construction documents. "Construction documents shall be of sufficient clarity to indicate the location, nature and extent of the work proposed and show in detail that it will conform to the provisions of this code and relevant laws, ordinances, rules and regulations. response: Is this a general comments or are there any specific items I am missing to address for building construction at this project? I want to know more in detail to make up my drawing for your review. I, also would like all the details necessary? 2. R303.5.1 and R303.5.2: heater: Response: we have a separate mechanical permit already. 3. R315.2.2: Fire alarm system Response: we will add additional info. or you can do redmark like other projects per RECEIVED) CITY OF TUKWILA FEB 2 2 2019 PERMIT CENTER 2 of 3 2/22/2019, 8:33 AM YahooMail - Re: Permit PW19-0007 - Roof Structure: No Change https://mail.yahoo.com/d/search/keyword=lee%20sipe/message... your convenience. Fire department. 2/18/19: Fire alarm system, smoke detector, is added. 4. Chimney: Toad bearing Response: As I verified, it was not part of roof structure, no load bearing. Lauri; could you know more about this from the field? VFire place was removed and roof repaired! How, What detailed framing plans. 2/18/19: No roof framing changed. Please refer to the attached info.. 5. R802,10.4: Alterations to trusses: Response: As I verified, there is no alteration on roof truss. Please verify in the field. Where the Fire place was! V2/18/19: No roof framing changed. Please refer to the attached info.. 6. Additional detailed permits, such as mech., plumbing, electrical, Public works, Response: all are done and approved. Thank you for your response; Lee Sipe Senior Plans Examiner City of Tukwila 206-431-3656 CAUTION: This email originated from outside the City of Tukwila network. Please DO NOT open attachments or click links from an unknown or suspicious origin. RECEIVED CITY OF TUKWILA FEB 22 2019 PERMIT CENTER 3 of 3 2/22/2019, 8:33 AM 9/3/2019 City of Tukwila Department of Community Development YOUNG KIM 13031 NE TENTH ST BELLEVUE, WA 98005 RE: Permit No. D18-0398 HIRSI RESIDENCE 3214 S 142ND PL Dear Permit Holder: Allain Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 10/15/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 10/15/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: D18-0398 ).e 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 jv4 sy City of Tukwila January 22, 2019 Department of Community Development YOUNG KIM 13031 NE TENTH ST BELLEVUE, WA 98005 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number DI8-0398 HIRSI RESIDENCE - 3214 S 142ND PL Dear YOUNG KIM, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: LEE SIPE at 206-431-3656 if you have questions regarding these comments. • This is a whole house remodel and needs the following clarifications. This may not be a complete list of corrections depending on the next information submitted for review. 1. R106.1.1 Information on construction documents. Construction documents shall be of sufficient clarity to indicate the location, nature and extent of the work proposed and show in detail that it will conform to the provisions of this code and relevant laws, ordinances, rules and regulations, 2. The garage has been enclosed, change the combustion and relief air to fuel burning mechanical equipment. Outdoor intake and exhaust openings shall be located in accordance with Sections R303.5.1 and R303.5.2. 3. R314.2.2 Alterations, repairs and additions. Where alterations, repairs or additions requiring a permit occur, or where one or more sleeping rooms are added or created in existing dwellings, the individual dwelling unit shall be equipped with smoke alarms located as required for new dwellings. R315.2.2 4.The roofing has been altered where the masonry fire place chimney was removed, altering the wood and wood - based products used for load -supporting purposes shall conform to the applicable provisions of this section. Wood roof framing R802.1 General 5. R802.10.4 Alterations to trusses. Truss members shall not be cut, notched, drilled, spliced or otherwise altered in any way without the approval of a registered design professional. 6. additional detailed plans will need submitted with trade permits for electrical, plumbing, fuel gas, mechanical. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. Jazzel Salzar Permit Technician File No. DI8-0398 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0398 PROJECT NAME: HIRSI RESIDENCE SITE ADDRESS: 3214 S 142 PL Original Plan Submittal X Response to Correction Letter # 1 DATE: 02/22/19 Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: i �cWO � 61 Building Division Public Works n Fire Prevention Structural Planning Division nPermit Coordinator u PRELIMINARY REVIEW: Not Applicable P1 (no approval/review required) DATE: 02/26/19 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required n Denied (ie: Zoning Issues) DUE DATE: 03/26/19 Approved with Conditions n (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 O PERMIT COORD COPY) PLAN REVIEW/ROUTING SLIT PERMIT NUMBER: D18-0398 PROJECT NAME: HIRSI RESIDENCE SITE ADDRESS: 3214 S 142ND PL X Original Plan Submittal Response to Correction Letter # Revision # DATE: 12/24/18 Revision # before Permit Issued after Permit Issued DEPARTMENTS: �S CU_ 11,-1,(0-104 Building Division Nle ►Z) f8 Public Works -Avk I -r -\'\ Fire Prevention Structural lyIJA ing Divis )n nPermit CoordiC'.tor t`RELIMINARY REVIEW: 1 lot Applicable n (io approval/review required) REVIEWER'S INITIALS: DATE: 12/2 /18 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required n Denied (corrections entered in Reviews) (ie: Zoning Issues) Approved with Conditions DUE DATE: 1/24. 19 n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 2 - 2% Plan Check/Permit Number: D 1 S 0 3 9 gj Response to Incomplete Letter # it Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: \ R S j 1- o V),S E - I IV V Project Address: -7_1 4. Contact Person: '6q Phone Number: Summary of Revision: �. 1+2- o pL cHIMO RECEIVED FEU 2 Z 2U19 R� CENTER Sheet Number(s): A2• I "Cloud" or highlight all areas of revision including date of revisio Received at the City of Tukwila Permit Center by: Entered in TRAKiT on W:\Permit Center\TemplatesWorms\Revision Submittal Form doc Revised: August 2015 zei( Hume 1 )aftol Contact. Safety & Health Claims & Insurance 0 Washington State Department of Labor & industries A-Zlndex Help • My L&I Workplace Rights Trades & Licensing CH REMODELING AND HANDYMAN Owner or tradesperson Principals CAMPOS FLORES, HECTOR, OWNER Doing business as CH REMODELING AND HANDYMAN WA UBI No. 603 382 381 15405 DES MOINES MEMORIAL DR APT #A102 BURIEN, WA 98148 206-850-2022 KING County Business type Individual License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. CHREMRH840MF Effective — expiration 07/06/2016— 08/10/2020 Bond American Contractors Indem CO Bond account no. 100363420 Received by L&I 10/20/2017 Bond history Insurance Security National Insurance Policy no. NAI56507600 Received by L&I 11/08/2018 Preferred Contractors Ins Co R Policy no. PCA5026-PC280548 Received by L&I 08/09/2018 $12,000.00 Effective date 09/08/2017 Expiration date Until Canceled $1,000,000.00 Effective date 11/08/2018 Expiration date 11/08/2019 $1,000,000.00 Effective date 08/09/2018 Expiration date 08/09/2019 Help us improve Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. Account is current. L&I Account ID 217,159-01 Doing business as CH REMODELING AND HANDYMAN Estimated workers reported Quarter 4 of Year 2018 "Less than 1 Workers" L&I account contact T1 / IDA HAYNES (360)902-5635 - Email: HAYN235@Ini.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. J Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve ROOFING TO MATCH W/ EXIST., TYP. MAINTENANCE WORK EXIST. AIR VENT (2"0) W/ MAX. 1/4" SPACED GALVANIZED MTL. NETS, TYP. EXIST. MTL FLASHING. TYP. EXIST. MTL FLASHING. TYP. ...111111 EXIST. TRUSS OR 2x12 RAFTERS W/ R-38 INSUL., TYP. EXIST, 2X4 STUD R-15 INSUL., TYP. 1/2" PLYWD. EXIST, FIN. PER ELEV. 0/ 15 LBS BLDG. PAPER OR AIR INFILTRATION BARRIER 0/ SHTG, PER STRL. x d • • EXIST, 2x4 STUDS, TYP. (EXIST.) FIRE BLK'G P.T. 2x LUMBER WHERE IN CONTACT W/ CONC., TYP. R -I5 tiJsu -. w/ -XIST Zx4r S -runs WO, C R-10 RIGID INSUL. AT PERIMETER, TYP. NOTE: 1. EXIST. STRUCTURE TO REMAIL WITHOUT CHANGE, TYP. 2. EXIST., ELEC., MECH., PLUMBING TO REMAIN WITHOUT CHANGE, TYP. 3. 6 MIL. VAPOR BARRIER, TYP. P.T. 2x LUMBER WHERE IN CONTACT IN/ CONC., TYP. 3/8 0 A.B. 32" 0.C. HOT DIPPED GALVANIZED OLX 2CY fl[oor 61'-10" EXIST. j////////////////// j//// 1 T V//%////7////.I O H X LLJ BED RM. 160 SF DRY WA / //////////// EXIST. EXIST. EXIST. EXIST. EXIST. DIN'G 62 SF t/////////////////////, REMODEL AREA: 567 SF DW ////////////////////---H—r//// j///////� L///////////i HTR ////////// ///////////////////// 3'-6" p t�c-t2 R,Ev1 oV t, NIG 011M 1&�-'(, -I DA—al -.40F 6�pN6 ro ISA---rcu t)cl S` , LIV'G 250 SF a 5'112.1C -TU .E , -gyp. KITCH 142 SF REF 00 00 ° ° // 4 BATH 43 SF ROOM 108 SF EXIST. i EXIST. LJ ROOM 136 SF EXIST. ROOM 120 SF EXIST. C EXIST. G. FL. AREA: 1,368 SF FL. PLAN SCALE 1/4"=1'-o" ///////// EXIST. EXIST. CONSTRUCTION NEW CONSTRUCTION 0 VENT TO OUTSIDE. MIN. 50 CFM AT BATHROOM & LAUNDRY ® VENT TO OUTSIDE. MIN. 100 CFM AT KITCHEN 118-038 PROJECT DESCRIPTION: HOUSE REMODELING, RE -ROOFING FOR MAINTENANCE, EXT. WALL AND ATTIC, CRAWL SPACE INSULATION, DRYWALL, KITCHEN CABINET & COUNTERTOP REMODELING. PROJECT ADDRESS: 3214 S. 142ND PL., TUKWILA, WA 98168 PARCEL TAX NO: 941500-0030 SEC/TOWNSHIP/RANGE: SW -15-23-4 LEGAL DESCRIPTION WILDWOOD TERRACE ADD ZONING: RESIDENTIAL LAND USE: CODE: '15 I.B.C. OCCUPANCY: "R-3" OCCUPANT LOAD: - TYPE OF CONSTRUCTION: V -B G. FL. AREA: 1,368 SF LOT SUMMARY: PARKING: NO CHANGE SEPARATE PERMIT RE UIRED FOR: Mechanical Eleotricat Plumbing Gas Piping City of Tukwila BUILDING DIVISION PROJECT INFO. SCALE N.T.S. PROPERTY OWNER ('S REPRESENTATIVE) ABDIRAHIM HIRSI 2114 S, 142ND PL., TUKWILA, WA 98168 T: 206-557-2389 PROJECT OWNER: SAME AS ABOVE GENERAL CONTRACTOR: ARCHITECT: 13031 NE 10TH ST., BELLEVUE, WA 98005 T: (206) 355-9686 - YOUNG KIM, AIA YK98005@YAHOO.COM TABLE OF CONTENTS: A1.1: PROJECT INFO., VICINITY MAP, SITE PLAN, FL. PLAN, DETAIL. FILE COP Permit No. pi$( Plan review approval Is subject to errors ana omissions. Approval of construction documents goes not authinze the violation of any adopted code. or ordinance. Receipt of approved Field Copy and con do s Is ac ledged: Date:717V.221 / "p' City of Tukw BUILDING DIVISION By: __0792_a r� . PROJECR AREA S 144TH ST. CVINCINITY SCALE N.T.S. V AP REVISIONS No changes shall be made to the scope of work witnout prior approval of the Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may Include additional plan review. 89' EX I 0715fill LOT SIZE: 8,400 SF G. FL. AREA: 1.368 SF I 1 i co css I rn I 30' EVIEWED FOR C o DE COMPLIANCE IAPPROVED nMA�R 01 201 . 1'SV City of Tukwila �UILDING DIVISION t O 'C) RECEIVED CITY OF TUKWILA DEC 242018 PERMIT CENTER NO. REVISION DATE PROJECT TITLE/OWNER HIRSI RESIDENCE 3214 SO. 142ND P1. TUKWILA, WA 98168 CONTACT: MR. ABDIRAHIM HIRSI (206) 557-2389 PERMIT SET NW ARCHITECTURELLC ARCHITECTURE 13031 NE 10TH ST. SUITE #B BELLEVUE, WA 98005 206.355.9686 REGISTRATION � 8171 REGISTERE ARCHI ECT �^ �] \44t0L l NWA PROJECT NO. 101-116 1 SHEET DRAWN BY EB CHK BY YK DATE 12/21/2018 SCALE AS NOTED TITLE FL. PLAN, EQ. SCHLE HEALTH DEPT. NOTES NUMBER Al .1 ALL COPY RIGHT, RIGHTS RESERVED r. 5 ROOFING TO MATCH W/ EXIST., TYP. MAINTENANCE WORK EXIST. AIR VENT (2"0 ) W/ MAX. 1/4" SPACED GALVANIZED MTL. NETS, TYP. EXIST. MTL FLASHING. TYP. EXIST. MTL FLASHING. TYP. Ow - 41. -40 SO- So- -40 -40O x w EXIST. TRUSS OR 2x12 RAFTERS W/ R-38 INSUL., TYP. EXIST, 2X4 STUDS, R-15 INSUL., TYP. 1/2" PLYWD. EXIST, FIN. PER ELEV. 0/ 15 LBS BLDG. PAPER OR AIR INFILTRATION BARRIER 0/ SHTG. PER STRL. EXIST, 2x4 STUDS, TYP. (EXIST.) FIRE BLK'G R-30 INSUL., TYP. WALL ASSEMBLY, TYP. P.T. 2x LUMBER WHERE IN CONTACT W/ CONC., TYP. — R-10 RIGID INSUL. AT PERIMETER, TYP. 4 2'-0" TYP 2'-0" 6 MIL. VAPOR BARRIER, TYP. P.T. 2x LUMBER WHERE IN CONTACT W/ CONC., TYP. 3/8 0 A.B. 32" 0.C. HOT DIPPED GALVANIZED EXT. WALL/FLOORING © CONC. FL., TYP. NOTE: 1. EXIST. STRUCTURE TO REMAIL WITHOUT CHANGE, TYP. 2. EXIST., ELEC., MECH., PLUMBING TO REMAIN WITHOUT CHANGE, TYP. 3. 61'-10" EXIST. EXIST. /////////////////////////A I I'////////� 0 x w A1.1 TYP. 0 ///////// BED RM. 160 SF x w DRY WA DIN'G 62 SF //////////// EXIST. REMODEL AREA: 567 SF FA / FIRE PLACE --I REMOVED, NO ROOF STRUCTURE (TRUSS) MODIFIED. ////////////////////iii/////////// ////// CL X4 EXIST. EXIST. ////////////////////�, V////////////////////l I f////////////� / / / / / / // / / /// BATH 43 SF \� DW 4'-0" K ITCH 142 SF REF 0®0 0®0 0 0 0 r////i/iii////////////////iii 3'-6" LIV'G 250 SF X W EXIST. ROOM 108 SF EXIST. ROOM 136 SF w 7///////i//, EXIST. EXIST. ROOM 120 SF WIRED FIRE ALARM SYSTEM WITH BATTERY BACK CK UP EXIST. EXIST, G. FL. AREA: 1,368 SF ///////// EXIST. EXIST. CONSTRUCTION NEW CONSTRUCTION 0 VENT TO OUTSIDE. MIN. 50 CFM AT BATHROOM & LAUNDRY 0 VENT TO OUTSIDE. CFT Fti WIRED FIRE ALARM SYSTEM WITH BATTERY BACK UP 1-0 PROJECT DESCRIPTION: HOUSE REMODELING, RE—ROOFING FOR MAINTENANCE, EXT. WALL AND ATTIC, CRAWL SPACE INSULATION, DRYWALL, KITCHEN CABINET & COUNTERTOP REMODELING. PROJECT ADDRESS: 3214 S. 142ND PL., TUKWILA, WA 98168 PARCEL TAX NO: 941500-0030 SEC/TOWNSHIP/RANGE: SW -15-23-4 LEGAL DESCRIPTION WILDWOOD TERRACE ADD ZONING: RESIDENTIAL LAND USE: CODE: '15 I.B.C. OCCUPANCY: "R-3" OCCUPANT LOAD: — TYPE OF CONSTRUCTION: V—B G. FL. AREA: 1,368 SF LOT SUMMARY: PARKING: NO CHANGE PROJECT INFO. SCALE N.T.S. PROPERTY OWNER ('S REPRESENTATIVE) ABDIRAHIM HIRSI 2114 S, 142ND PL., TUKWILA, WA 98168 T: 206-557-2389 PROJECT OWNER: SAME AS ABOVE GENERAL CONTRACTOR: ARCHITECT: 13031 NE 10TH ST., BELLEVUE, WA 98005 T: (206) 355-9686 — YOUNG KIM, AIA YK98005©YAHOO.COM TABLE OF CONTENTS: A1.1: PROJECT INFO., VICINITY MAP, SITE PLAN, FL. PLAN, DETAIL. S 140TH ST. v1 PROJECR AREA S 142ND PL. S 144TH ST. VINCINITY MAP SCALE N.T.S. 89' LOT SIZE: 8,400 SF G. FL. AREA: 1,368 SF 30 SITE PLAN SCALE 1"= 20'-0" Cd rn IRE OCT 15 2O1 REVIEWED FOR CODE COMPLIANCE APPROVED MAR 01 2019 City of Tukwila BUILDING DIVISION b 1 8-4 398 CORRECTION LTR# ED RECEIVED CITY OF TUKWILA FEB 22 2019 PERMIT CENTER NO. REVISION DATE PROJECT TITL /OWNER HIRSI RESIDENCE 3214 SO. 142ND Pl. TUKWILA, WA 98168 CONTACT: MR. ABDIRAHIM HIRSI (206) 557-2389 PERMIT SET NW ARCHITECTURE,LLC. ARCHITECTURE 13031 NE 10TH ST. SUITE #B BELLEVUE, WA 98005 206.355.9686 REGISTRATION 8171 REGISTERED RCHITFT YO NG T. T 0 W SHINGTON NWA PROJECT NO. 101-116 cr)DETAIL DRAWN BY EB CHK BY YK DATE 12/21/2018 SCALE AS NOTED TITLE FL. PLAN, ELEVATIONS NUMBER A2.1 ALL OOPY RIGHT RIGHTS RESERVED