Loading...
HomeMy WebLinkAboutPermit D18-0400 - ZUMIEZ - INTERIOR RENOVATIONZUMIEZ 2646 SOUTHCENTER MALL EXPIRED 10/06/19 D18-0400 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 9202470010 2646 SOUTHCENTER MALL Project Name: ZUMIEZ Permit Number: Issue Date: Permit Expires On: D18-0400 2/1/2019 7/31/2019 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD, WA, 92013 DAVID MURPHY 910 LENORA STREET S207 , SEATTLE, WA, 98121 HARDESTY & ASSOCIATES INC 711 W 17 ST - UNIT D2 , COSTA MESA, CA, 92627 HARDEAI066PP Phone: (206) 708-1682 Phone: (949) 723-2230 Expiration Date: 12/26/2019 DESCRIPTION OF WORK: INTERIOR RENOVATION OF AN EXISTING ZUMIEZ RETAIL CLOTHING STORE LOCATED IN SOUTHCENTER MALL. Project Valuation: $175,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: IIB Electrical Service Provided by: TUKWILA Fees Collected: $3,751.53 Occupancy per IBC: M Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. AH provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agr e to the conditions attached to this permit. Signatur- Date: Z// // Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterally braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles shall be ventilated in accordance with the applicable provisions of the International Mechanical Code. 9: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one-third and lower one-third of the water heater's vertical dimension. A minimum distance of 4 -inches shall be maintained above the controls with the strapping. 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 12: Manually operated flush bolts or surface bolts are not permitted. (IFC 1010.1.9.4) 16: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 13: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 14: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 15: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 17: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1010.1.9) 18: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 19: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 20: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1010.1.9.1) 21: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1013.1) 22: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1013.6.1) 23: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on-site generator. (IFC 1013.6.3) 24: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1008.3.5) 28: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 26: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 25: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 29: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2437. 30: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 31: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 32: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 33: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 34: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.11 of the International Building Code. 35: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1) 27: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 36: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 37: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1700 BUILDING FINAL** 0611 EMERGENCY LIGHTING 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING 0502 LATH/GYPSUM BOARD 0406 SUSPENDED CEILING CITY OF TUKT' ;A Community Develop,:tent Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Pei', t No. D1F — 0.10 0 Project No. Date Application Accepted: 12„ -Z1- ) V Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 9202470010 Site Address: 2 Southcenter Mall Suite Number: 2115 Floor: 2 Tenant Name: Zumiez PROPERTY OWNER Name: David Murphy Name: Westfield City: Seattle State: WA zip: 98121 Address: 2800 Southcenter Email: dmurphy@murphyvarey.com City: Seattle State: WA zip: 98188 CONTACT PERSON — person receiving all project communication Name: David Murphy Address: 910 Lenora Street S207 City: Seattle State: WA zip: 98121 Phone: (206) 708-1682 Fax: Email: dmurphy@murphyvarey.com GENERAL CONTRACTOR INFORMATION Company Name: TBD Address: Company Name: NA Architect Name: David Murphy City: State: City: Seattle State: WA Zip: Phone: Fax: Email: dmurphy@murplhyvarey.com State: Contr Reg No.: Phone: Exp Date: Tukwila Business License No.: H:Applications\ Forms -Applications On Line 2011 Applications\Permit Application Revised - 8-9-I I.docx Revised: August 2011 bh New Tenant: ❑ Yes ❑ .. No ARCHITECT OF RECORD Name: NA Company Name: Murphy Marey, ps Company Name: NA Architect Name: David Murphy Address: 910 Lenora S207 City: Seattle State: WA Zip: 98121 Phone: (206) 708-1682 Fax: Email: dmurphy@murplhyvarey.com State: ENGINEER OF RECORD Name: NA Address: Company Name: NA Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: NA Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATIO 206-431-3670 Valuation of Project (contractor's bid price): $ 175,000 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): Interior renovation of an existing Zumiez retail clothing store located in Southcenter Mall Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes FIRE PROTECTION/HAZARDOUS MATERIALS: Compact: Handicap: No If "yes", explain: Sprinklers Automatic Fire Alarm ❑ None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes I No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications Forms -Applications On Line\2011 Applications'Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1St Floor 2"d Floor 3,181 3,181 0 0 II -B M 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes FIRE PROTECTION/HAZARDOUS MATERIALS: Compact: Handicap: No If "yes", explain: Sprinklers Automatic Fire Alarm ❑ None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes I No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications Forms -Applications On Line\2011 Applications'Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Page 2 of 4 'e PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PE'.i�y •.Y BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW; # (i'fit ZED AGENT: Id Signature: Print Name: David Murphy Mailing Address: 910 Lenora Street S207 H:\ Applications' Forms -Applications On Line'2011 Applications'.Permit Application Revised - 8-9-1 l.docx Revised: August 2011 bh Date: 12/27/2018 Day Telephone: (206) 7084682 Seattle WA 98121 City State Zip Page 4 of4 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT I QUANTITY I PAID $2,326.68 D18-0400 Address: 2646 SOUTHCENTER MALL Apn: 9202470010 $2,326.68 DEVELOPMENT $2,217.08 PERMIT FEE R000.322.100.00.00 0.00 $2,192.08 WASHINGTON STATE SURCHARGE• 8640.237.114 0.00 $25.00 TECHNOLOGY FEE $109.60 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R16747 R000.322.900.04.00 0.00 $109.60 $2,326.68 Date Paid: Friday, February 01, 2019 Paid By: HARDESTY & ASSOCIATES INC Pay Method: CHECK 105528 Printed: Friday, February 01, 2019 10:46 AM 1 of 1 fill :Mg/SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $1,424.85 D18-0400 Address: 2800 SOUTHCENTER MALL Apn: 9202470010 DEVELOPMENT PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R16267 R000.345.830.00.00 0.00 $1,424.85 $1,424.85 $1,424.85 1.424.85 • Date Paid: Thursday, December 27, 2018 Paid By: MURPHY VAREY P.S Pay Method: CHECK 15096 Printed: Thursday, December 27, 2018 1:06 PM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 b,g pyo Project: g 241.41G -7Z- Type of Inspection: <V' L.& `lgi44-t— Address:: / �� ,,,y 210i1,0 ,_4C,t/ V•� t -✓L Yii Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone No: Approved per applicable codes. EJ Corrections required prior to approval. COMMENTS: Inspector: Date: REINSPECTION F REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit 06 i oo INSPECTION NO. PERMIT Na CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter BIvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 2-0I"s 1 L Type of In�}pection: 41/L-1)/^4 iJ✓ Address: 2&' , 146 rvi) Date Called: Special Instructions: Mot 4Pe Lazio rRie (240 F't'R /tcRass ,�cM. MoD Coo RT) Date Wanted: it -S -'-‘e) ], p.m. Requester: / 6' Phone No: yOZQ-7&O - F757 LJApproved per applicable codes. Corrections required prior to approval. COMMENTS: lag (L - Inspector: Date: C REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspeciion. INSPECTION RECORD 'Q Retain a copy with permit INS ECTION N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-367 Project: Type of ectiaU Irt Address: . ‘11,0 fl Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. OMMENTS: L 64111eS, t'ftieL5 Date: lnspector. l l ,, REINSPECTION FEE REQUIRED. Prior to next inspection. fee ust be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit L -oYoFO INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: fl ZtJ► M i e.2- Type of Insp ction: L.4114 € 3 Address: s „ 24%�a�, I"I ypsu Date Call d: �f Special Instructions: Date Wanted: 3- 15- ZO"/ a.m. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector:(y....Z. REINSPECTION REQ Date: UIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Z WI Type of Inspection: Type ,v '/ Address:'''' 0(94 6 A•I f' f 1 ULA Date Called: }'1/l/Ai.A._ Special Instructions: Date Wanted:.rr' .3--14Pt.9 p.m. Requester: Phone No: LJApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: - --��-,�-1 Pte► 104).?<6.6..1. Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 otoo Project: 2lkn1&Z. Type of Inspection: ✓4L ii Address: zipitty Lt ' L ! Date Called: ,e— Special Instructions: Date Wanted: a.m. 7^ 4Z=^ VII COI' 7 Requester: Tc4 Phone No: 44()&'3 O 0137 Approved per applicable codes. D Corrections required prior to approval. COMMENTS: ���ortzvwf� Akthit,(54 8k (..9 rm-u-ok, 1 -f -E (Ai <<-t, G sat 6-V ‘/(,6 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 bI,ej foo Project: ZU r''112--, Type of Inspection: vw447 Address: �'s&,L[[��� `F tt�� CCTY►'{i i - out_ Called: r t _ Special Instructions: Date Wanted: Wim. 3- 11- I9 p.m. Requester: E15 Phone No: N/�, '&Ob 2 Q e137 Approved per applicable codes. Corrections required prior to approval. COMMENTS: (7/4-Aieel(`P.4 4-) Oon-tr ct,frt, Cj,`Le_ ,fie- cdudLile_. Inspector^W P� Date: 3 -ll _zzi REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Dib octco Project: ZlinellE2— Type of=n7 /Ziyilit'n Address: %iz Date Called: Special Instructions: Date Wanted: 6_ ,GI a.m p.m. Requester: Phone No: Approved per applicable codes. % Corrections required prior to approval. COMMENTS: ►�� p Inspector: ^'\* 4%J4 Date: J _11 REINS-ECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 cs 04130 Project: Z11 rd1 L Type of Inspection: "FriArvviv-ti Address: Z410 z k ira— fl4 &s Date Called: Special Instructions: Date Wanted: 3 S • trci p.m. Requester: Phone No: «o(0 36C) 6151 Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: S 7 tlxizt7t74rxiAt v47 —tJwios.' - �b v(-cto -0404(4,0PAZ Inspector: ot7 Date: .°;<1-1(1 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION bfeoztov 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: Type of Inspection: Address: . r{k / Date Called: Special Instructions: Date Wanted: m. ,26- cc) Requester: Phone No: 0 Approved per applicable codes. L] Corrections required prior to approval. COMMENTS: - — ors 111y_,4_ t9�1T 4- i -Qtr-- C& Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 9/3/2019 City of Tukwila Department of Community Development DAVID MURPHY 910 LENORA STREET S207 SEATTLE, WA 98121 RE: Permit No. D18-0400 ZUMIEZ 2646 SOUTHCENTER MALL Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 10/6/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at Least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 10/6/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, •r-tA Bill Rambo Permit Technician File No: DI8-0400 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 r . PERM i. .reNN t ;....41I'lt® PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0400 DATE: 12/27/18 PROJECT NAME: ZUMIEZ SITE ADDRESS: 2800 SOUTHCENTER PKWY X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: LS Mc 1 L -L �IB Building Division WA 12-21 - I � Public Works PM S 16\ ►/116 Fire Prevention Plalinmg Drvtston Structural Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 1/01/19 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required ❑ Approved with Conditions n Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 1/29/19 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg D Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 HARDESTY & ASSOCIATES INS' 11{) nc F anol Contact. Safety & Health Claims & Insurance CWashington State Department of O Labor & Industries Page 1 of 2 (Search L&I A-L1.clex Help My 1.&1 Workplace Rights Trades & Licensing HARDESTY & ASSOCIATES INC Owner or tradesperson Principals HARDESTY, WILLIAM SCOTT, MEMBER HARDESTY, ROBERT D (End: 01/16/2018) HARDESTY, ROBERT E (End: 01/16/2018) HARDESTY, WILLIAM S (End: 01/16/2018) HARDESTY, LORI A (End: 01/16/2018) ALLEY, RICHARD, AGENT (End: 01/16/2018) Doing business as HARDESTY & ASSOCIATES INC WA UBI No. 601 423 943 711 W 17TH ST UNIT D2 COSTA MESA, CA 92627 949-723-2230 Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. HARDEAI066PP Effective — expiration 10/17/1994— 12/26/2019 Bond MERCHANTS BONDING CO (MUTUAL) Bond account no. wa13466 $12,000.00 Received by L&I Effective date 09/14/2009 09/08/2009 Expiration date Until Canceled Insurance United Specialty Insurance Com $1,000,000.00 Policy no. LIG0031100 Received by L&I Effective date 10/25/2018 10/25/2018 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601423943&LIC=HARDEAI066PP&SAW= 2/1/2019