Loading...
HomeMy WebLinkAboutPermit D18-0093 - RILEY ROSE LLC - TENANT IMPROVEMENTRILEY ROSE, LLC 467 SOUTHCENTER MALL D18-0093 Parcel No: Address: 0 City of Tukwila 0 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: httn://www.TukwilaWA.Aov DEVELOPMENT PERMIT 9202470010 467 SOUTHCENTER MALL Project Name: RILEY ROSE, LLC Permit Number: D18-0093 Issue Date: 5/31/2018 Permit Expires On: 11/27/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD, CA, 92013 ABEL LOPEZ 3880 N MISSION ROAD , LOS ANGELES, CA, 90031 Phone: (213) 765-2978 JAMES E JOHN CONST CO INC Phone: (360) 696-0837 1701 SE COLUMBIA RIVER DR , VANCOUVER, WA, 98661 JAMESEJ173MM Expiration Date: 11/7/2019 RILEY ROSE, LLC 3880 N MISSION ROAD , LOS ANGELES, CA, 90031 DESCRIPTION OF WORK: TENANT SPACE ALTERATION. BUILD SALES ARE WITH NEW WALL FINISHES AND FLOORING. NEW LIGHT LAYOUT WITH SYSPENDED CEILING ACCENTS IN THE SALES AREA TO BE INSTALLED. BUILD PARTITION WALLS TO SEPARATE SALES AREA AND BACK OF HOUSE FUNCTIONS. RELOCATING EXISTING TOILET AREA AND BUILDING NEW TOILET AREA. INSTALLING NEW AIR CONDITIONING DUCTS AND AIR SUPPLY REGISTERS. REPLACING ELECTRICAL SERVICE SYSTEM WITH NEW TRANSFORMER AND ELECTRICAL PANELS. Project Valuation: $273,962.00 Fees Collected: $5,190.20 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: IIB Electrical Service Provided by: TUKWILA Occupancy per IBC: M Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: No Volumes: Cut: 0 Fill: 0 Number: 0 Permit Center Authorized Signature: Date: 5-3-- j 9 1 hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: I-SR`fatJ DES G12oSE l.t_.t e7z. - Date: S/3 I/ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 4: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 1: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be Tess than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 0 0 2: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 3: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 5: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1010.1.9) 6: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 7: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 8: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1010.1.9.1) 9: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1013.1) 10: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1013.6.1) 11: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1018.1) 12: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on-site generator. (IFC 1013.6.3) 13: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1008.3.5) 17: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 15: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 14: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 0 0 18: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2437. 20: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 21: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 22: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.11 of the International Building Code. 23: Post address on storefront per approved Westfield standards. 16: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 24: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 25: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 26: ***BUILDING PERMIT CONDITIONS*** 27: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 28: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 29: The special inspections for steel elements of buildings and structures shall be required. All welding shall be done by a Washington Association of Building Official Certified welder. 30: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 31: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 32: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 33: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterally braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 34: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 35: Fire retardant treated wood shall have a flame spread of not greater than 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 36: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 37: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 38: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 39: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 40: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 41: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0611 EMERGENCY LIGHTING 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING 0502 LATH/GYPSUM BOARD 4027 SI -COLD -FORM WELD 4046 SI-EPDXY/EXP CONC 0406 SUSPENDED CEILING CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. ^� Project No. Date Application Accepted.'" Date Application Expires: "" !.41 . CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** Site Address: 467 Southcenter Mall Tenant Name: Riley Rose, LLC PROPERTY OWNER Name: Abel Lopez Name: Westfield City: Los Angeles State: CA zip: 90031 Address: 467 Southcenter Mall Email: abel.l@forever21.com City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Abel Lopez Address: 3880 N. Mission Road City: Los Angeles State: CA zip: 90031 Phone: (213) 765-2978 Fax: Email: abel.l@forever21.com GENERAL CONTRACTOR INFORMATION Company Name: TBD Company Name: CMA Address: 3316 Fuhrman Ave. East, Suite 250 Architect Name: Cortland Morgan Address: Address: 711 N. Fielder Road City: Arlington State: TX City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: H: Applications\Forns-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh King Co Assessor's Tax No.: Suite Number: 1545 Floor: First New Tenant: m Yes ❑..No ARCHITECT OF RECORD Company Name: Harbor Consulting Engineers, Inc. Company Name: CMA Address: 3316 Fuhrman Ave. East, Suite 250 Architect Name: Cortland Morgan Phone: (206) 709-2397 Fax: (206) 709-2398 Address: 711 N. Fielder Road City: Arlington State: TX Zip: 76012 Phone: (817) 635-5696 Fax: Email: cindy@cmaia.net ENGINEER OF RECORD Company Name: Harbor Consulting Engineers, Inc. Engineer Name: Darren S. Johnston Address: 3316 Fuhrman Ave. East, Suite 250 City: Seattle State: WA zip: 98102 Phone: (206) 709-2397 Fax: (206) 709-2398 Email: djohnston@harborengineers.com LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Riley Rose, LLC Address: 3880 N. mission Road Cit': Los Angeles State: CA Zip: 90031 Page 1 of 4 BUILDING PERMIT INFORMATION = 206-431-3670 Valuation of Project (contractor's bid price): $ 273,962 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): Tenant space alteration. Build sales are with new wall finishes and flooring. New light layout with suspended ceiling accents in the sales area to be installed. Build partition walls to separate sales area and back of house functions. Relocating existing toilet area and building new toilet area. installing new air conditioning ducts and air suppl registers. Replacing electrical service system with new transformer and electrical panels. Will there be new rack storage? ❑ Yes VI.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: J Sprinklers WI Automatic Fire Alarm 9 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 9 Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\ Applications\Forms-Applications On Line \2011 Applications\Perrnit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1s` Floor 4,591 0 0 II -B M 2nd Floor -: 3rd Floor Floors %i thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: J Sprinklers WI Automatic Fire Alarm 9 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 9 Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\ Applications\Forms-Applications On Line \2011 Applications\Perrnit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFORMATION — 206-433-0179 Scope of Work (please provide detailed information): N/A Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District m ...Tukwila 0...Water District #125 ❑ ...Water Availability Provided Sewer District ® ...Tukwila 0 ...Sewer Use Certificate 0 .. Highline ❑... Valley View ❑ .. Renton 0... Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): 0 ...Civil Plans (Maximum Paper Size — 22" x 34") 0 ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): 0 ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way 0 O ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer 0 ...Cap or Remove Utilities 0 ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑ ...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance 0 .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank 0 .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line O .. Grease Interceptor O .. Channelization ❑ .. Trench Excavation 0 .. Utility Undergrounding O ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size .. WO # ❑ ...Water Only Meter Size WO # ❑...Deduct Water Meter Size 0 ...Sewer Main Extension Public 0 Private 0 0 ...Water Main Extension Public 0 Private 0 FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water 0 ...Sewer Monthly Service Billing to: Name: 0 ...Sewage Treatment Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 3 of 4 J PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR A THORIZE AGENT:. Signature:y� _t Date: 03/08/2018 Print Name: Abel Lopez Day Telephone: (213) 765-2978 Mailing Address: 3880 N. Mission RD., Suite 3062 H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Los Angeles CA 90031 City State Zip Page 4 of 4 PermitTRAK ACCOUNT. QUANTITY $69.87 D18-0093 Address: 467 SOUTHCENTIER MALL Apn: 9202470010 $69.87 Credit Card Fee Credit Card Fee R000.369.908.00.00 0.00 $2.04 $2.04 DEVELOPMENT $67.83 ADDITIONAL PLAN REVIEW TOTAL FEES PAID BY RECEIPT: R15364 R000.345.830.00.00 1.00 $67.83 $69.87 Date Paid: Monday, September 10, 2018 Paid By: BRYAN DESGROSELLIER Pay Method: CREDIT CARD 03963J Printed: Monday, September 10, 2018 1:30 PM 1 of 1 SYSTEMS Page 2 of 2 CO TUKWILA ETRAKIT 6200 SOUTHCENTER BLVD TUKWILA, WA 98188 206-433-1870 CITY OF TUKWILA Date: 09/10/2018 01:29:23 PM CREDIT CARD SALE MASTERCARD CARD NUMBER: **********1277 K TRAN AMOUNT: $69.87 APPROVAL CD: 03963J RECORD #: 000 CLERK ID: Bill Thank you! Customer Copy https://classic.convergepay.comNirtualMerchant/transaction.do?dispatchMethod=printTra... 9/10/2018 `eceipt Number R14618 DESCRIPTIONS ACCOUNT PermitTRAK QUANTITY PAID $5,498.00 D18-0093 Address: 467 SOUTHCENTER MALL Apn: 9202470010 $3,731.53 DEVELOPMENT $3,579.01 PERMIT FEE R000.322.100.00.00 0.00 $3,050.41 PLAN CHECK FEE R000.345.830.00.00 0.00 $524.10 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $152.52 TECHNOLOGY FEE R000.322.900.04.00 0.00 $152.52 EL18-0292 Address: 467 SOUTHCENTER MALL Apn: 9202470010 $840.70 ELECTRICAL $800.67 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $800.67 TECHNOLOGY FEE $40.03 TECHNOLOGY FEE R000.322.900.04.00 0.00 $40.03 M18-0040 Address: 467 SOUTHCENTER MALL Apn: 9202470010 $746.38 MECHANICAL $710.84 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $677.69 TECHNOLOGY FEE $35.54 TECHNOLOGY FEE R000.322.900.04.00 0.00 $35.54 PG18-0048 Address: 467 SOUTHCENTER MALL Apn: 9202470010 $179.39 PLUMBING $170.85 PERMIT FEE R000.322.100.00.00 0.00 $137.70 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 TECHNOLOGY FEE $8.54 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R14618 R000.322.900.04.00 0.00 $8.54 4" i 4 $5,498.00 Date Paid: Thursday, May 31, 2018 Paid By: JAMES E JOHN CONSTRUCTION CO Pay Method: CHECK 71559 Printed: Thursday, May 31, 2018 2:25 PM 1 of 1 SYSTEMS f \ f 1 eceipt Number R14091 DESCRIPTIONS PermitTRAK ACCOUNT f QUANTITY PAID $1,879.26 D18-0093 Address: 467 SOUTHCENTER MALL Apn: 9202470010 $1,458.67 DEVELOPMENT $1,458.67 PLAN CHECK FEE 8000.345.830.00.00 0.00 $1,458.67 EL18-0292 Address: 467 SOUTHCENTER MALL Apn: 9202470010 $200.17 ELECTRICAL $200.17 PLAN CHECK FEE 8000.345.832.00.00 0.00 $200.17 M18-0040 Address: 467 SOUTHCENTER MALL Apn: 9202470010 $177.71 MECHANICAL $177.71 PLAN CHECK FEE R000.322.102.00.00 0.00 $177.71 PG18-0048 Address: 467 SOUTHCENTER MALL Apn: 9202470010 $42.71 PLUMBING " $42.71 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R14091$1,879.26 R000.322.103.00.00 0.00 $42.71 Date Paid: Tuesday, March 27, 2018 Paid By: RILEY ROSE LLC Pay Method: CHECK 600248 Printed: Tuesday, March 27, 2018 2:56 PM 1 of 1 CPWSYSTEM INSPECTION NO. INSPECTION RECORD Retain a copy with permit D l -6093 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pry' t; I � i Type of Inspection: �Lcfl Fr NAL ress: Ad Date Called: Special Instructions: Date Wanted: /0- 2 - Zolg- a.m. p.m. Requester: Phone No: InApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Bc,1,441 Inspector:3g a.0._ Date: `y z_V z6„...., REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit pt? -04,5 PERMIT N0. CITY OF TUKWILA BUILDING DIVISIONI 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 Permit Inspection Request Line (206) 438-9350 Project: , //hy^` / T w e Type of Inspe n l Address: Date Called: Special Instructions: Date Wanted: I a r p.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. OMMENTS: m- /4-6. Inspector: Date: 107z4/4 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36V0 Permit Inspection Request Line (206) 438-9350 Pro ect: L TZ(s—C Type of Inspection: ► .cf'►�{ 1.-.i ...1.141 1'I s Address: Lite? Stra4-f ati-kr KALL Date Calle d. U ---.._ Specia Instructions: Date Wanted: Fo-Z9-1otS p,,,. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: t (>16 A a Co. Lit,\ - L4 Inspector: l 71 (J6& Date: . n, ffee usl: be REINSPECTION' FEE REQUIRED. Prior to next inspecti paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit Dt8-0©93 PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pro ect: K. Roc. Type of Inspection: rr I Eyre � r,. c o+ L 3 6-I- b , Address: � � a LL `�67 SOI ., eeh r Date Called:ccJ! ��11 Special Instructions: Date Wanted: /0-22-20/8 ra p.m. Requester: /� T vi . Phone No: Approved per applicable codes.. Corrections required prior to approval. CENTS: AL 1- /ie :_xt 0 - di` t /rel- l S ild iIJL �O /� T vi . iD, R -uv v,sS . 1-14 ii, r S foe_ ftp are v, d. L. 9 ( re- ed,,, -7 Inspector: Da Date:, v z 2 ^g REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 60 9 3 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: /40y �e Z-1-‘7, Type of Inspection: 5-051°54490V ///G Address: 5t.7.501,27/C f)' MfrI- I, Date Called: Special Instructions: Date Wanted: 0f /F18 a pm. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: c+- $vsfg D Inspector: Date: l67' REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. H INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 DE -0093 Pr ct: K i ast Type of Inspection: L i N6 d/ Address 'lb? SeAtvrtkie NALL ..1:731A7 S tksteruteA Cell; Special Instructions: Date Wanted/ a `O -3- Z401 p.m. Requester: Phone No: AApproved per applicable codes. COMMENTS: Corrections required prior to approval. GLAzF ot- 5 p el Cep - Inspector: 73 Date: /0 3-201g REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit �J�g-c3 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proj k Ir‘k C Tvppe�of lns eec'tion: wi"/ i'1 ' (.Dyf5t► L.. Address: c �,,��Date 1*o7 Sow%.c�i UA 4 C ed: Special Instructions: Date Wanted: 9 -iii- Cr p.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. Inspector:312 lj , Date: 1-/q- 7/ ' REINSPECTION FEE REQUIRED. Prior to next inspection, fee must he paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. l INSPECTION RECORD p2 Retain a copy with permit Dig 3 _ V INSPEC ON N0. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Fr (23.,ct: � C Type of Inspectio /t� )1 ' A dyes 11(0-7 U Date Calle lJ Special Instructions: Datented: ���,(� ly ` If —Z. i2 p.m. Requester: Phone No: c4Approved per applicable codes. 1 \4 Corrections required prior to approval. COMMENTS: `f itSiak1 cs L imiedi 5tupenitidi ,7c.k. SLt �e eet l Inspector: 1;� •� Date 9.../( REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Cal[ to schedule reinspection. Date: z_06(d, INSPECTION RECORD Retain a copy with permi INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 PreV. r, c Type�off Ins ection: Ad / & 7 ress: e Date Call d: Special Instructions: Date Wanted: 5 -3 I - 7-0 irg p.m. Requester: Phone No: Approved per applicable codes. L, Corrections required prior to approval. COMMENTS: 5tOek—VOT L/414/Y-02D1;1 0 < Inspector:.3 LQQ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 big-oo93 Project: LLC. Type of lnsp ction: L16ypsun. 80,44 Address: Date aIle Special Instructions: Date Wanted: .m 8 30 - zoCr p.m. Requester: Phone No: nApproved per applicable codes. • Corrections required prior to approval. COMMENTS: a WAUJ a QH-j' * (1: -CA -61e /4/-1:01- OS.T.-��lC dmfcpm lr _SI 4vr►r 1' r 6irclax) J 'i clumv hovel L`4 c 5 , aeon Getitr Fot Sus . cf., i f( rJ he °dpi /2 Le 4/ F r . Inspect or%% Dat, REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 be -0093 Project: lL tipsti• 'C- Typ�f Inspection: Fr mi d- A� rn Date Called: tI Special Instructions: Date Wanted: E. 77- 2-57( a.m. p.m. Requester: Phone No: Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: irY2P014 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit g O INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Pro' • I 'icX14" Type (1f...inspection.; f—✓'' 4W 1 Address: y6-7 5, MAIC Date Called: Special Instructions: Date Wanted: mss, p� Q8 - 2' - .c�i`!� a.m. p.m. Requestz P �ao2i_7�'I '5“ Approved per applicable codes. COMMENTS: Corrections required prior to approval. /1 )/Y..t./0/1/(45- nn Nh!Yr. cote) pILJi pprov&Oi (,0-2„--70-36be Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. b8-0093 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter BIvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Ng 008 Pr .j c`: Pt LI12 sr� Type of Inspection: SI EPC'xr/y Address 1/47 Sorg-►' ce �/�. 1 1 L L ` Date Called: Special Instructions: Date Wanted: 7`19 -"als( pm. c i LeiPhon Requeste4 No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: C *1-- ee'vAj - ffoxi-ed 0102.(K5 a .1PU ileti (0 )1a S „wips04 Se -t- - X P Cfei/ erviL-ehneei4- —/zair=1 .4.defe W�viJijouit ai-t0 0a12(7/0d-e�c *5'2Ja2v ps2 Inspector: Date :70. �y REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD etaitt "copy with periti1t» PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: e"? � � � 14 k -e-- Type of Inspection: Address: AContact Suite #:1— 56. Mal freigiv't Person: /Z-'---6i/Ct" Special Instructions: Phone No.: 0 -Approved per applicable codes. Corrections required prior to approval. COMMENTS: Ft 14-pfizive-O Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: , 14---- Date: (O J2c JI 5( Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doe 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a Copy with perit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: I g692....„ 1 FM SP PO efAl c..-4 Fire Alarm: Type of Ins pio. Address:!^ Suite #:' p i ! Contact Person. Special Instructions: /7/1 , Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1 FM SP PO efAl c..-4 Fire Alarm: Hood & Duct: 5p-1- 1 vi le---( 02-- -Ft 46c ( f\Joer 14ppieved , ALece.) - f / Eiv'r /� �, �..oz c S /� 5ki,wlie/ t-? -vii eJ r Y1 - Aor - Gt �- _ Permits: 0k., tD c 6 "- 1( A/ (-eefc/5 m,d /7/1 1 Needs Shift Inspection: (.1Sprinklers: 1 Fire Alarm: Hood & Duct: I Monitor: 6t, -G,, til a t^ Pre -Fire: Permits: Occupancy Type: /7/1 Inspector: ym Date: /0/« /1't Hrs.: I .--4 n $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip„ Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a Copy with perimit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: %` iCl/ t Sprinklers: (-7 Hrs.: Fire Alarm: Type of In n: j` Address: 467+ Suite #:56 Pre -Fire: �� 1/0 Contact Person: Special Instructions: Prevt 6E- Ho cA I, IL OAA/&) led 1v fm__ Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: (-7 Hrs.: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: On Si -- A/L-� x%74- 19,.( Prevt 6E- Ho cA I, IL OAA/&) led 1v fm__ 4P5- `n -k-f— -1/12 fki c/5/ L SA r, t- D'7 7`(.e) 7 ,x C k To C®v 6'12_ 5p < iv%t 6)25 6?AA,�i�/ L--' ) exec, - I,$ s .(4L - c/ 1/ kr,o sX-ee lez Needs Shift Insp ction: Sprinklers: (-7 Hrs.: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: /31 Inspector: 7 4;4., Date: /614.-Jfc Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip:: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit tor— 093 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project;,.. Sprinklers: Typ of Inspection: Address:Contact Suite #: y()` wk,( t,ik Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: _ Occupancy Type: - C (A -o Csvz.r . ki c-c., ,vx. .. 1\esm_ co,,)(4,r- (i.Nov ''L?r- ' )0.4c,.(4-. (-6 Pit)%Ajv, - Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: _ Occupancy Type: Inspector: ^ - r-vrn '3 Date: 5/5-f / 5 Hrs.: /. O T $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 uc nc Harbor Consulting Engineers, Inc. STRUCTURAL ENGINEERING CALCULATIONS for the RILEY ROSE SOUTHCENTER TENANT IMPROVEMENT 2800 Southcenter Mall Tukwila, WA 30 ,E zev8 `_‘,: . LANCE KY 18 2.E3 City of Tukwila D VL ICN CORRE TION LTR# Note: See the index page following this cover sheet for applicability of the engineer's seal. 30 April 2018 Prepared for: Riley Rose Contact: Mr. Abel F. Lopez 3380 North Mission Road Los Angeles, CA 90031 Tel: (213)-765-2978 Prepared by: Harbor Consulting Engineers, Inc. 3316 Fuhrman Avenue East Suite 250 Seattle, WA 98102 RECEIVED CCTV OF TUKWILA APR 30 2018 PERMIT CENTER 18-0093 3316 Fuhrman Avenue East Suite 250 • Seattle, Washington 98102 • Telephone 206.709.2397 • Facsimile 206.709.2398 uc nc Harbor Consulting Engineers, Inc. INDEX TO STRUCTURAL CALCULATIONS: ITEM: PAGES: Storefront Framing Member Structural Design B1 — B2 Seismic Force Determination for Roll -Up Door 51 — S1 Roll- Up Door Reference Materials D1 — D4 Index 3316 Fuhrman Avenue East Suite 250 • Seattle, Washington 98102 • Telephone 206.709.2397 • Facsimile 206.709.2398 DCS/4n) L. o,va EST 7,J, 5of`I r Aril? /%%hJG!A L/n/r0`; " 5p/+n1 G/,art To SvP/'O'Qf STo1eL fR,o pr5P49-r Gv = (/5 PS? -IL. 4 So '/, t BPsP(4) _ /Zo #/, Gv.Q _, /z007) is 52020t, 8 /14 ni.t._ 52020 ' -0 0,4(5o1200) d -5w1 3t3l Ef 0 /,73 7,73 "tr Errsoks; %) ` /2,013ing 5)0 = (2) 2471 Tr; 3 ✓01.• S(/Zal(/7)1. /725 0, 3 zi.€5 d32 3Z1 (a9 :x/0')(2) 12.019.3 N vs� (2) - /o':x x /tA4 sr ac210 ok 9 ADEp page L /7'G. i7 1 1J�S/ q"/ /N roes A i`ro. SOFT/ r ntiP not-fc 1 /a L/,gyre/- L., SP,4rJev7X.iZ To .nipplaer JrSW EP , 4" P/5',07.4 -Y 1rV s (1 S PjG) { S) #. $0 #/, t SPlF (4) = /240 /?%/1Z4,c, WA72 /2 o (/.) a l 2 8 a SfEcv19 = MM 35280 - /,/8ir1.3 rk 0,G (Sacob ) 3s26o #-4' PEC4-0 c t/ on/ $"xctx/`,61¢ Fy=so,4, cJx s 1,703 i/, 3 x= 70/7 ;4" < .Sh = (2) 41o37,7) 5Pv.e 5'(/Zvi (/4) f/72$ d = _ 3 EZ 30'7 29 x/04)(217.00 r( �a G O. I/Je-._(2 ). -� VA Smet 57k17 BOar HEf 21. Pc,,? L.. = / g / 44-vreL 1e/z ' Rose 7:-7- .rr AT V/.S T By: Date: 0: S. ,i'oH.,/.r7oN 24 Fe23 // S on/ r Checked: Date: uc nc HARBOR CONSULTING ENGINEERS, INC. Seattle, Washington Phone: (206) 323-6000 www.harborengineers.com Job #: Scale: Sheet: Do/ / Q Z .DSS/ 4r,r 5 Rr0,40.4 L/r4 t. To S LPforQ r SToieEP fr ftPr''7 A- ,v- , 4C/4 G/N77e1.: 60l3/oX /a '-o „ G _ 9 fl/r 1.47 kV =. (/SPJP)(?) 4- so #1 8PJF(4) = /zo #� 077/f $ 43 1. .2-x = 2,113:/9 AA u/.Q Z / &. O (9f) 2. /�s8 a /v1/77,,e, = g = _ - 3 5), ✓ J`41eVy :. 0. 71 is < _ (21 (2/7"."743 Fi o,( (33000) r3.4" -F1 Grip/v.' ✓w 5(2 )(/ I/28 1e Q._ 0, /125 "4 = t/®< 3 $-F Ey 38 t (29 )0/0 c) (24Z,143) 757 a ° J6 ( E) + 6 �le L , k / el ef 5re-el- .SYvo 13k 1/eirveR roe L- 9 ‘..,/• c De 5, 6,..1 TyP/c4C .74m8 571/PS Ar 14/A.14,- ()Pei*, 4 S/ �, /mss °' tD x Cj k / eef „ ;o r2 1 1 IIrTAr" Sk = 0,8 /13.'15 1 x = 2, 433 MT = SPJr�( W .) . 274'/ 2 I I 1 Al mM, = //6`'- 21(/5)212 .9/13.#-r` E VA-17O»I _ 8 5R.-QtI, = M4.1 9 //"3 3 O, 3 _ = T& ill -< 5,> = 0,6/) 71 Ti Fe O.& (3380 4&.7.e -C7 0"/ 5cv.1I g 3' et e2 3sg /29 ,,,,0') 2,133 1"' a , vfa_ 6" ,c �, >. /884 sem- 57Z/0 S X-C J' rnss R/ LEY RQ5E ? 4r WS T B0.s .7'0Li.Jt7e2e4 t�3 //9 5 r /� AE FRO ^ , / , v Checked: Date: LC fCSeattle, HARBOR CONSULTING ENGINEERS, INC. Washington Phone: (206) 323-6000 www.harborengineers.comScale: Job #: Sheet: eZ /B 2 JOE M/iv.I 1 G 1-0/77ie4C O/@ 11°4-1--`/P £7e'e ,4-r $ To426" ,14":7/4r Wi 51 lit h 15- (Zr t f .oaR) Goevjoeva-p :-- be) qp 40 p /,0 ler = 2,5 �p = 0, 4 5pr We hi StCC f ON 0, (✓ 0)0 ,0) (7s� r1ic 0 /C' _ ©,7fe e 0,70.12 49 = 21,4e ) 2 Ar: 0,7 rO, 3 5vf ..re wP i PMiri rrm , ryl (A's o ) Oil [0.3 (1.0)(1i0)1751)) /Sgt °o OJE ToTA4 poi 'Ce se -Ls/ e 17el/cn/ L4AD 0J 2 /9 415t- PO(/P . ?OO, /N 0N SI) Q/LY Ro 7/17 yvsT By: Date: AS %7-0i/NJTON 2 (. fee./ 8 5roi2 ,.E'o/VT Checked: Date: uc nc HARBOR CONSULTING ENGINEERS, INC. Seattle, Washington Phone: (206) 323-6000 www.harborengineers.com Job #: Scale: Sheet: 5/ / 5 / COKNELL Innovative door solutions:" CRESTWOOD INDUSTRIAL PARK MOUNTAINTOP, PA 18707 PHONE (800) 233-8366 WWW.CORNELLIRON.COM DATE: 11/9/2017 PROJECT: RILEY ROSE LOCATION: Tallahassee, FL DEALER: CORNELL STOREFRONT PHONE: 800-882-6773 SYSTEMS ADDRESS: 140 Maffet St, Suite 200 Wilkes Barre, PA 18705 ATTN: Dan Bulkley CORNELL#: E1167338 Submittal LEED® RECYCLED CONTENT INFO FOR JOB: 751.0 Lbs. - Total Weight of All Units 75.0 Lbs., 10.0% - Post Consumer Content 82.0 Lbs., 10.9% - Post Industrial Content 157.0 Lbs., 20.9% - Total Recycled Content SHOP DRAWING REVIEW 0 SUBMIT SPECIFIC ITEM At REVIEWED 0 FURNISH AS CORRECTED 0 REJECTED ❑ REVISE AND RESUBMIT REVIEW IS ONLY FOR GENERAL CONFORMANCE WITH THE DESIGN CONCFPT OF THE PROJECT AND GENERAL COMPLIANCE WTH THE INFORMATION GIVEN IN THE CONTRACT DOCUMENTS. CORRECTIONS OR COMMENTS MADE TO THE SHOP DRAWINGS OR TO THE SUBMITTAL DRAWING DURING THIS REVIEW DO NOT RELIEVE THE CONTRACTOR FROM COMPLIANCE WITH THE REQUIRMENTS OF THE PLANS AND SPECIFICATIONS. APPROVAL OF A SPECIFIC ITEM SHALL NOT INCLUDE APPROVAL OF AN ASSEMBLY OF WHICH THE ITEM IS A COMPONENT. THE CONTRACTOR IS RESPONSIBLE FOR: ALL QUANTITIES. DIMENSIONS TO 8E CONFIRMED AND CORRELATED AT THE JOBSITE; INFORMATION THAT PERTAINS SOLELY TO THE FABRICATION PROCESSES OR TO THE MEANS, METHODS, TECHNIQUES. SEQUENCES AND PROCEDURES OF CONSTRUCTION. INCLUCENG JOINERY, COORDINATION OF HIS/HER WORK WITH THAT OF ALL OTHER TRADES: AND FOR PERFORMING ALL WORK IN A SAFE AND SATISFACTORY MANNER. DISTRIBUTION OF DOCUMENTS BY THE CONTRACTOR SHALL CONSTITUTE APPROVAL. BY: Hipolito Bautista DATE: 12-12-2017 7 m K rn Fr cn 1HOI3M 1V1O1 U3Wf1SN00 lSOd 0 0 0 ivi LSnaNi lSOd 0 CO 0 CJ1 v a ca a310A032:1 1b101 N 0 CO 0 \o 0 11v130 1N31N00 a310A0321®0331 ONIMV210 1VNI0I8O 0 LIO-so-1.1. CS m- 0 0 D m co pg O 8 IF D73m rr>F >0 C/) Cn mm m0 m< rm z 0 cn 0 c D m 0 -u m m0 D p O � r0 z0 � D 0 0 N CD 0. g. co m O rn 1 4) W 0) 0 0 W Io c a m a m m m r m 1 0 z 0 r w 0 m z 0 0, 0 m 0 z 2 8 c) z m 1 1 0 m Tm 0 z cn 0) m 0) m 0) D 0 Co 330 zx 0 > <r0, O 0 C2C inCig l m- Dym .Zz o,m00 m M CO Cm 0) 0 r r z 0 08 .Z1 Iil 0 m Z O X XI 0 x Om9 IT 10'-0" 11 <0-o0,0 o0 2002 mrmc Z m z00 0 m 15" DOOR OPENING HEIGHT OVERALL DOOR HEIGHT oz c 0 z 0) m303m fgagg gin N g-48 < 5.c 3 DO 2E$ Rag ss $ c O O o _ a'n7 N 8Er '12°* :S3I1S121313V21VH31N32121113 :HS/Nld 7 7VR131VW N000 AaLN3 :SNOUVoldlo3dS ?/oloW 0 2 a This order includes CUSTOM DESIGNS. These submittal drawings must be returned with matching estimate to release for fabrication. m O z v m 0 0 S0 W ps 8 IF D� rr >0 'O m m0 m rm z O .'0 0) 0) 0 C m 0 0 X 0, 0 8 n O4 z m r r 0) 73 O m -n .Z1 0 z cn m 0) m 0) v 'o H101M DNIN3d0 a 2 10 110 w z 0 0 m z z G) J VAS dOZD aooa ANIN3 N ' > Oo 0 o X0 O1•1 mm 0 D < m o Op _z S m0 0r • i ns . OS oeo X 0 (n N 3 0m O Z { mtn 0O Z rm m orq A ; N C c 3 D A O m 0 3 Z 0 m x m z m 0 :Sa3N31SV3 31aaVS :S2J N31SV3 A18113SSV :S213N31SV3 3100VS :S1:13N31SV3 A18W3SSV ..ti - VLLZO ..V - VLLZD 2 m S i � m 0 3m w 0, r2 W m m r - E -- >z CO �i 00 0 0 m This order includes CUSTOM DESIGNS. These submittal drawings must be returned with matching estimate to release for fabrication. utl Harbor Consulting Engineers, Inc. STRUCTURAL ENGINEERING CALCULATIONS for the RILEY ROSE SOUTHCENTER TENANT IMPROVEMENT 2800 Southcenter Mall Tukwila, WA r ). J. CGS, : (. 1, 'LANCE f�►1�, C' `: J MAY 18 2018 City of Tukwila BUILLYNC D;VV,;ION Note„ See the index page following this cover sheet for applicability of the engineer's seal. 16 March 2018 Prepared for: Riley Rose Contact: Mr. Abel F. Lopez 3880 North Mission Road Los Angeles, CA 90031 Tel: (213)-765-2978 Prepared by: Harbor Consulting Engineers, Inc. 3316 Fuhrman Avenue East Suite 250 Seattle, WA 98102 RECEIVED CITY OF TUKWILA MAR 2 7 2018 PERMIT CENTER 3316 Fuhrman Avenue East Suite 250 • Seattle, Washington 98102 • Telephone 206.709.2397 • Facsimile 206.709.2398 bit (xlq1h Ireil SOP w Harbor Consulting Engineers, Inc. INDEX TO STRUCTURAL CALCULATIONS: ITEM: PAGES: Storefront Framing Member Structural Design B1 — B2 Seismic Force Determination for Roll -Up Door Si — Si Roll -Up Door Reference Materials D1 — D4 Index 3316 Fuhrman Avenue East Suite 250 • Seattle, Washington 98102 • Telephone 206.709.2397 • Facsimile 206.709.2398 DE S/4 A) 1, 6-'4 4 F1 T.?, .. SPAN L ,. T To SvPpOR1 5rogt pRn, Soffit AMP P,,A,S*GtA L/n/rOL !'V = (15' Ps! (2. zwsinAT 4' 50 � t 8' PSP (4) = /Zo 44 Mow wit /20(/1) 1/2 SR��a /14 ; 52_024) #X - 46('50Q00) ,5a/f S(/249%(/7) 1-/728 S ZOZo # /i /, 73 7,7 3 3" (Z9.1(/0()(2) 12.013 • /l XC Zr 0� /6i j ? fys50,0i : 2,/7f1/7 3 rx$ /2.09`3 init 5 = (2) 2•/7T n o' 3 zze.%h -e 63Z Ok ole o ZN o� Use ii (2) - /0 x L �" x /G� stmt. SN,v l3c2x h'eitpE 4"/ iN rawm m -r sP4 G/41p„ TO svf?a2T S?OEEt' ieclev off/ r /ri✓p i"zA rc 1-149 L- re -i-; 8 X r x et Fr= soles: " vrX _ i,703 ;4 3 I x z 70/7 M t k1,' i. (IsP.r -)(s) t SO #4 r 8.P1F(4) = /20 n/rupc, = ui.f2 /20(/i) It 3sZ$o 4.-y tA4352$0 . Fb O, G (500, b ) : . 3 8 ar (2 9 x o ") (21 7.00 65, o a (/J&__(2e�j_ -...8 ... k. 511/0_ _t3o)c H A- for? L= ,E>/ Rose 7:17 AT WST By: Date: fl 5..7-011 d'�iv 2 4 F3 I/ S Sroi'e- E'Q o/v T Checked: Date: LIC nc HARBOR CONSULTING ENGINEERS, INC. Seattle, Washington Phone: (206) 323-6000 www.harborengineers.com Job #: Scale: Sheet: / / Q Z ' Pa.P 4e.r Skever)yetr4 `/ev7M. To 5 uPPom r 52p-'r ,S'C /T,f "-P P;f'. 4 /NTNG i _ Nriwo_A I, co L X / e rF 1-0 G = 9 fl,ysy...47 xi/ 5)- 0:7/f;43 ; (f) = / Z o GV = (/SPfr) (?) # 5001 j �9 f z Ix =' 2,/113%nIt . w� /Z-,0* (9f2. z 60 a m' max; S SS ,p = f 5;60 3 R : 0, 71I 147 < .S VT. Fi 0.L(33oo0) w.e`. _ Cav,o'1(9)f/7Z� 0.It2-il = 1 /o 3 $F E1.: 38, (2 x/0 c)(2)(2.>43) 7?7 z L x 18414' = s7L0 Avk i/e/tpeR mic Z_=-`9/ /✓rem VY/4,i T`iP/ CSG JAin13 S7LDS Ar W+4,>e- OP /\41. 4 5 n X CIS/ " / $ eir H = 151-o" �° /-0,s �.� 14.1 i. ,� � Ar Sx := o. 8 // , 3 -7-A618�g T x = 2, 433 iti Wil A i. tiii/g 21(/5)24% = ELgv r oi.r .91/3#..." 5,F'TQ ^- — 0, t7 Fb O.(, (33000) rGl -C77 ON , . -c- ✓ Scv./ $ (2 7) (/SJ %` /7 2: 5 _ 0,1359 i 3 8t ez 39 g /29 w/o ‘) .2, 133 a o h� x r ',G 1 8 9 4 ST Z SILOS ...✓f > i '90 a-/t"m6 R /LEY , o s E 7 Ar Y � V/ BD. s, ,roi /e4r7o '4Dat�3 /.,8 Teo RGr ,.R O ^/ I / /- ' \ Checked: Date: Job #: UC fCSeattle, HARBOR CONSULTING ENGINEERS, INC. Washington Phone: (206) 323-6000 www.harborengineers.com Scale: Sheet: �2 /B 2 DEnro2miive 1.-O/rpie-►S fO.# i L -v? z2t9c7X *f StodeE'eo/4 r SE/5/14 C w, 15 f h / 5' (Znd P2.042) Go ✓J?eV4Tr lis 2,14 rwz Ops zr .0 Fp = re sod: 4 5pt LIQ r,. (i 2 0,7 /5. = 0,7 C.31219 r i" m urn (Alp) s h) DOOR 0,7 :(�,o)(4a) (7 r's t1,0) 2.13 #- o,/ ro,3Sp;WP 1 ori l-0.3 (1,0)(1,o) (-751 UJE_. Torsi poRc qr./ 4,47? ,o/' RehLL - vn 1200)? /rv,,rf.4.hA-77 vim+/ /Z 2(;TV) R/L --Y Rafe TI, /4--r VV T By: Date: .a 7 /NJTON 2 & reLo 5 aR/E20/1/ 7 - Checked: Date: u nc HARBOR CONSULTING ENGINEERS, INC. Seattle, Washington Phone: (206) 323-6000 www.harborengineers.com Job #: Scale: Sheet: 5//0/ COKNELL Innovative door solutions:" CRESTWOOD INDUSTRIAL PARK MOUNTAINTOP, PA 18707 PHONE (800) 233-8366 WWW.CORNELLIRON.COM DATE: 11/9/2017 PROJECT: RILEY ROSE LOCATION: Tallahassee, FL DEALER: CORNELL STOREFRONT PHONE: 800-882-6773 SYSTEMS ADDRESS: 140 Maffet St, Suite 200 Wilkes Barre, PA 18705 ATTN: Dan Bulkley CORNELL#: E1167338 Submittal LEED& RECYCLED CONTENT INFO FOR JOB: 751.0 Lbs. - Total Weight of All Units 75.0 Lbs., 10.0% - Post Consumer Content 82.0 Lbs., 10.9% - Post Industrial Content 157.0 Lbs., 20.9% - Total Recycled Content SHOP DRAWING REVIEW lie REVIEWED 0 REJECTED ❑ SUBMIT SPECIFIC ITEM ❑ FURNISH AS CORRECTED ❑ REVISE AND RESUBMIT REVIEW IS ONLY FOR GENERAL CONFORMANCE WITH THE DESIGN CONCFPT OF THE PROJECT AND GENERAL COMPLIANCE WTH THE INFORMATION GIVEN IN THE CONTRACT DOCUMENTS. CORRECTIONS OR COMMENTS MADE TO THE SHOP DRAWINGS OR TO THE SUBMITTAL DRAWING DURING THIS REVIEW DO NOT RELIEVE THE CONTRACTOR FROM COMPLIANCE WITH THE REQUIRMENTS OF THE PLANS AND SPECIFICATIONS. APPROVAL OF A SPECIFIC ITEM SHALL NOT INCLUDE APPROVAL OF AN ASSEMBLY OF WHICH THE ITEM IS A COMPONENT. THE CONTRACTOR IS RESPONSIBLE FOR: ALL QUANTITIES. DIMENSIONS TO BE CONFIRMED AND CORRELATED AT THE JOBSITE; INFORMATION THAT PERTAINS SOLELY TO THE FABRICATION PROCESSES OR TO THE MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES OF CONSTRUCTION. INCLUCING JOINERY, COORDINATION OF HIS/HER WORK WITH THAT OF ALL OTHER TRADES: AND FOR PERFORMING ALL WORK IN A SAFE AND SATISFACTORY MANNER. DISTRIBUTION OF DOCUMENTS BY THE CONTRACTOR SHALL CONSTITUTE APPROVAL. BY Hipolito Bautista DATE: 12-12-2017 m U1 IHOI2M 1V101 Er— co 0 -1 0 0 Z 0) C m 0 0 0 0 0o Q 0 --I Z v c 0) D O 0 0 0 01 Q cn a313AO J 1V1O1 O C0 0 0 4t 3 9NIMYMa IVNIOI IO 0 z CO F co 8 D;m rr >0 o m m0 rm z 0 0 c D m 0 m m0 yr 7r 0E r-0 z0 0 0 m r 0 n • al r °D 0 m z 0 m 0 0 z 08 0 z m r r cn0 Z1 -n m 7J 0 cn m m v 0 m 0 8 D : 0 m z 2 0 0 x ma zn D «D1 O Ocic 1 mm m D m m mmo ymmm m iiss/ z m lil 11 S 0 0 v0 2,- 0 mA 05' m { 0X 01= jzi 0 mz0 - x-1Ox 0z 10'-0" 111 15" DOOR OPENING HEIGHT OVERALL DOOR HEIGHT oz m2 0 0 z o) N m�O�m ail oag -- 3e- gga a •o t N m IMN Sal! i ili11114 F, fli! lig' , +OM, 1 lil:Dig 13 piiiiiii anigith eliirg l' 1 i1IjI!hf ;—,':z7- z 3 O 7c o D Oil kg ill ill f ill $ Kot g z o. a h 3 m= E m O • -1 w 0 11 1 _if h • W °o a1. p$aaa 45 ▪ eg• c3ASR- g cl 3 c -Be .[ $ 3e a K" R 1I 1 i.1 :SNO/1VOld133dS 2/O.OW :lsn.LN3Wd/n 0 t This order includes CUSTOM DESIGNS. These submittal drawings must be returned with matching estimate to release for fabrication. 0) 0 Z ONIMVLIO IVNIDI O 0 O ISm+ NN O 3g CO m.. N 0 0 D m W 8 8 IF �r m 2 � >0 m M 0 < rm 21)z 0 0) 0) 0 c D m m PJ0 m A 0 - 0 .Z1 0 G) 00 mm 0) 0) m co U c 0 p 1 t 0 Z m CD 0 m -n 0 2 cn -1 0) m 0) 47, m N 0 O 8 100 9££L9110 3 i HlOIM ONIN3d0 0 2 t fro 1[ o� m z r- 0 0 0m mOD mD 71z O S5 -n 71 m m Vm� 0>< X- 0 -I 00 m zm 0800 z>0 0o01 O yr J V -1S BOZO y > • g o0 f• ' 0 Z O xi <z - < mcA co z_ m 710 or :S213N31SV3 31aaVS :S213N3ISV3 A181413SSV ..ti - VLLZD 2 m O co co 0> 0, 3 affil z m—Zm i a5,1. 0 � dllir 11114 z sill 0 r:li 0 73 m 0 -I 71 os m CP Dp rA mm z cnD r r m 0) z 0 m y . D 0is3 CO 0w 0 3s X N 3 • 0 <>< 0 H cg Tam o-4 :82i3N31SV3 31aGVS :Sa3N31SV3 11181+113SSV ..ti - VLLZO m71 <>x m co alg y13S Vim; 0m i -I• 4 2. com� z c c m 0 0 m This order includes CUSTOM DESIGNS. These submittal drawings must be returned with matching estimate to release for fabrication. DY/Dir 4 Lighting Summary LTG -SUM 2015 Seattle Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Info Compliance forms do not require a password to use. Instructional and calculating cells are write - protected. Project Title: Riley Rose - Southcenter Date 1/1/2018 Applicant Information. Provide contact information for individual who can respond to inquiries about compliance form information provided. Company Name: TES Engineering Company Address: 25760 First Street Applicant Name: Lawrence M Thomas Applicant Phone: 440.871.2410 Applicant Email: Ithomas@tesengineering.com For SDCI Use Project Description ❑ New Building ❑ Addition Q Alteration ❑ No Lighting Scope Include PROJ-SUM form (included in envelope forms workbook) with lighting compliance forms. Interior Lighting System Description E Interior Lighting Plans Included RECEIVED CITY OF TUKWILA MAR 2 7 2018 PERMIT CENTER Interior Lighting Power Allowance Method ❑Q Building Area Method ❑ Space -by -space Method Select method used in project. Interior Lighting Permit Date Q Before January 1, 2018 ® January 1, 2018 or after Select date range for the initial building permit application or initial TI permit acceptance Interior Lighting Controls E All C405.2.1 - C405.2.8 Lighting Controls ❑ Additional Efficiency Package Option C406.4 Enhanced Digital Lighting Controls To comply with C406.4, no less than 90% of the total installed interior lighting power shall comply with the required controls per C406.4. ❑ C405.2 Exception 5 Luminaire Level Lighting Control (LLLC) Dwelling Unit Interior Lighting Exterior Lighting System Description ❑ Exterior Lighting Plans Included Permanently installed interior lighting fixtures in dwelling units comply with: Q C405.2 thru C405.5 Commercial Lighting Controls and LPA Q C406.3 High Efficacy Lighting Q R404.1 Residential High Efficacy Lighting. Dwelling nit lighting complies with SEC Residential provision in lie"u of SEC Commercial provision3 !l CC., ( 0 No Dwelling Units Building Additions Refer to Section C502.2.6 for additional requirements. Compliance Method Lighting systems in addition area comply with all applicable provisions as a stand alone new construction project R V . Y 0 .- C;tv o4 Tu''wila =enol lighting ❑ Lighting systems in addition are combined with existing building lighting systems to demonstrate compliance ❑ Addition is combined with existing: For interior lighting projects, include new + existing -to -remain interior lighting fixture wattage in Proposed Lighting Wattage table in LTG -INT -BLD or LTG -INT -SPACE four. For exterior lighting projects, include new + existing -to -remain exterior lighting fixture wattage in Proposed Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG -EXT form. DIM)* Lighting Summary, cont. LTG -SUM 2015 Seattle Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2017 Project Title: Riley Rose - Southcenter Date 1/1/2018 Change of Space Use ❑ Existing interior lighting systems in areas under -going a change in space use are upgraded to comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2). !dentify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in LTG -INT -BLD or LTG -INT -SPACE form. Interior and Exterior Lighting Alterations Select all Lighting Power and Lighting Control elements that apply to the scope of the retrofit project. If project includes multiple spaces (rooms separated by ceiling height partitions), each space where less than 20% of the existing fixtures are added, altered or replaced can be combined on a single LTG -INT -SPACE form. Spaces where 20% or more of the fixtures are added, altered or replaced and additions may be combined onto one lighting power compliance form. Parking garages and exterior lighting have 50% thresholds. Refer to Section C503.6 for additional requirements. All alteration lighting controls shall be commissioned per C408.3. ❑ No changes are being made to the interior or exterior lighting systems and existing space uses and configuration are not changed. Lighting Power Interior lighting Parking garage Exterior lighting Spaces with more lighting than threshold added, altered or replaced (20% int., 50% garage, 50% ext.) ❑ ❑ ❑ Spaces with less lighting than threshold added, altered, or replaced (20% int., 50% garage, 50% ext.) ❑ ❑ ❑ Lamp and/or ballast replacement only — existing total wattage not increased ❑ More lighting than threshold replaced - Total lighting power of new + existing -to -remain fixtures shall comply with total LPA per Sections C405.4.2 and C405.5.2. Include new + existing -to -remain fixtures in Proposed Lighting Wattage table in LTG -INT -BLD, LTG -INT -SPACE or LTG -EXT form. Less lighting than threshold replaced - Total lighting power of new + existing -to -remain fixtures shall not exceed the total lighting power prior to alteration. Include new + existing -to -remain fixtures in the Proposed Lighting Wattage table in LTG -INT -BLD, LTG -INT -SPACE or LTG -EXT form. The threshold for interior lighting is 20% of the luminaires within an enclosed space, for parking garages the threshold is 50% of the luminaires within the garage, and for exterior spaces the threshold is 50% of the total installed lighting power for the exterior luminaires. Lighting Controls Interior lighting Parking garage Exterior lighting New wiring installedto serve added fixtures and/or fixtures relocated to new circuit(s) ❑ ❑ 4 New or moved lighting panel ❑ ❑ . Interior space is reconfigured - luminaires unchanged or relocated only ❑ New wiring or circuit - For interior lighting, provide required manual controls per C405.2.3, occupancy sensor controls per C405.2.1, daylight responsive controls per C405.2.4 and application specific lighting controls per C405.2.5. For exterior lighting, provide required controls per C405.2.7. New or moved panel - Provide all applicable lighting controls as noted for New Wiring and automatic time switch controls per C405.2.2. Reconfigured interior space - Provide all required lighting controls that apply to a new interior space. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured spaces. 4. Interior Lighting - Space -By -Space Method LTG -INT -SPACE 2015 Seattle Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 20 Project Title: Riley Rose - Southcenter Date 1/1/2018 Calculation Area NOTE 9 0 New Construction Q Addition - Q Addition stand alone + existing Q Spaces where < 20% of Q Spaces where >_ 20% of Q Spaces where the Use is luminaires are replaced luminaires are replaced changing (C505) For SDCI Use LPA Calculation ® Standard Q Additional Efficiency Package Option C406.3 Reduced Interior Lighting Power DP1 Type To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA. Refer to C406.3 for additional requirements. User Note Sales Area Maximum Allowed Lighting Wattage NOTE 1 3 Location (plan #, room #) Space Type Ceiling Height NOTE 2 Gross Interior Area in ft2 Allowed Watts per ft2 Watts Allowed (watts/ft2 x area) Sales Area Sales area 11 3517 1 . 140 4009 Restroom Restroom: facility for the visually impaired 8 60 0. 970 58 Hallway Corridor: all other 8 79 0.480 38 2 16 32 Total Area 3656 Retail Display Allowance from LTG -INT -DISPLAY Proposed Retail Display Lighting from Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total LTG -INT -DISPLAY Proposed Watts Lobby Art/Exhibit Display Allowance from LTG -INT -DISPLAY NOTE 6 2762 Allowed Watts 4106 Proposed Lighting Wattage NOTE 3 Location (plan #, room #) Fixture Description NOTE 4, 5, 6 Number of Fixtures Watts/ Fixture NOTE Watts Proposed Sales Area DP1 15 150 2250 Sales Area DP2 3 40 120 Sales Area LA1 3 16 48 Sales Area LP1 16 11 176 Sales Area LS1 40 3 120 Restroom LD1 1 16 16 Hallway LD1 2 16 32 Proposed Retail Display Lighting from Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total LTG -INT -DISPLAY Proposed Watts 2762 Interior Lighting Power Allowance COMPLIES Note 1 - List all unique space types per Table C405.4.2(2) that occur in the project scope. Select space type category from drop down menu. Note 2 - Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f. Note 3 - List all proposed lighting fixtures including exempt lighting equipment and existing-to-remain fixtures. Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 5 - For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank. Note 6 - Existing-to-remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing in fixture description. Note 7 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other appro ved source. For luminaires with screw-in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer. For line voltage track/busway systems, enter the larger of the attached luminaire wattage or 50 watts/lineal foot, or enter the wattage limit of permanent current limiting device. Note 8 - Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. Enter all proposed lobby art/exhibit display fixtures in LTG-INT-DISPLAY form only. Note 9 - Calculation Area Details: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building lighting systems to demonstrate compliance. Refer to C502.1. b. For alterations and building additions, provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table. If a building addition will comply as combined with the overall existing building lighting systems, include all applicable existing Space Types and gross interior areas. c. If less than 50% of existing lighting fixtures will be replaced, provide total existing lighting wattage (prior to alteration) in the space provided in the Maximum Allowed Lighting Wattage table. d. If lighting alteration project includes some building areas or spaces where < 50% of luminaires are replaced, and other areas or spaces where z 50% of luminaires are replaced, then these areas or spaces may be documented separately. If multiple forms will be completed to demonstrate compliance for the total scope of the alteration project, describe scope covered in form in Us er Note section. STATE OF CALIFORNIA INDOOR LIGHTING CEC-NRCC-LTI-01-E (Revised 04/16 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE N RCC-LTI-01-E Indoor Lighting (Page 1 of 6) Project Name: Forever 21 - Mission Valley Date Prepared: 1/30/2018 A. General Information Climate Zone: 7 Conditioned Floor Area: 10,671 Unconditioned Floor Area: 0 Building Type: ® Nonresidential 0 High -Rise Residential 0 Hotel/Motel 0 Schools 0 Relocatable Public Schools © Conditioned Spaces 0 Unconditioned Spaces Phase of Construction: 0 New Construction 0 Addition El Alteration Method of Compliance: 0 Complete Building 0 Area Category ❑ Tailored Project Address:1640 Camino Del Rio North, Space 112 B. Lighting Compliance Documents (select yes for each document included) For detailed instructions on the use of this and all Energy Efficiency Standards compliance documents, refer to the Nonresidential Manual published by the California Energy Commission. YES NO COMP. DOC. TITLE E7 0 NRCC-LTI-01-E Certificate of Compliance. All Pages required on plans for all submittals. 0 0 NRCC-LTI-02-E Lighting Controls, Certificate of Compliance, and PAF Calculation. All Pages required on plans for all submittals. El 0 NRCC-LTI-03-E Indoor Lighting Power Allowance El 0 NRCC-LTI-04-E Tailored Method Worksheets 0 0 NRCC-LTI-05-E Line Voltage Track Lighting Worksheets ❑ ■ NRCC-LTI-06-E Indoor Lighting Existing Conditions MAR 0 9 2018 CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance April 2016 STATE OF CALIFORNIA INDOOR LIGHTING CEC-NRCC-LTI-01-E (Revised 04/16 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE N RCC-LTI-01-E Indoor Lighting (Page 2 of 6) Project Name: Forever 21 - Mission Valley Date Prepared: 1/30/2018 C. Summary of Allowed Lighting Power Conditioned and Unconditioned space Lighting must not be combined for compliance Indoor Lighting Power for Conditioned Spaces Indoor Lighting Power for Unconditioned Spaces 01 Installed Lighting NRCC-LTI-01-E, Table H, page 5 Watts Installed Lighting NRCC-LTI-01-E, Table H, page 5 Watts + 16'292 + 0 02 Portable Only for Offices NRCC-LTI-01-E, Table G, page 4 + 0 Field Inspector ❑ 03 Minus Lighting Control Credits NRCC-LTI-02-E, page 2 - 0 Minus Lighting Control Credits NRCC-LTI-02-E, page 2 NRCI-LTI-05-E - Must be submitted for a Power Adjustment Factor (PAF) to be recognized for compliance. 0 04 Adjusted Installed Lighting Power (row 1 plus row 2 minus row 3) _ 16 292 Adjusted Installed Lighting Power (row 1 minus row 3) _ 0 Complies ONLY if Installed <_ Allowed (Box 04 < Box 05) Complies ONLY if Installed <_ Allowed (Box 04 < Box 05) 05 Allowed Lighting Power Conditioned NRCC-LTI-03-E, page 1 Alterations with replacement luminaires that have at least 50/35% lower power compared to the original existing luminaires, may instead use the allowed wattage from NRCC-LTI-06, page 2 16,653 Allowed Lighting Power Unconditioned NRCC-LTI-03-E, page 1 Alterations with replacement luminaires that have at least 50/35% lower power compared to the original existing luminaires, may instead use the allowed wattage from NRCC-LTI-06, page 2 0 D. Declaration of Required Certificates of Installation Declare by selecting yes for all of the Certificates that will be submitted. (Retain copies and verify forms are completed and signed.) YES NO Compliance Document/Title In 0 NRCI-LTI-01-E - Must be submitted for all buildings 0 Field Inspector © 0 NRCI-LTI-02-E - Must be submitted for a lighting control system, or for an Energy Management Control System (EMCS), to be recognized for compliance. 0 Field Inspector EJ 0 NRCI-LTI-03-E - Must be submitted for a line -voltage track lighting integral current limiter, or for a supplementary overcurrent protection panel used to energize only line -voltage track lighting, to be recognized for compliance. 0 Field Inspector ❑ El NRCI-LTI-04-E - Must be submitted for two interlocked systems serving an auditorium, a convention center, a conference room, a multipurpose room, or a theater to be recognized for compliance. 0 Field Inspector ❑ ❑ NRCI-LTI-05-E - Must be submitted for a Power Adjustment Factor (PAF) to be recognized for compliance. 0 Field Inspector ❑ ® NRCI-LTI-06-E - Must be submitted for additional wattage installed in a video conferencing studio to be recognized for compliance. 0 Field Inspector CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance April 2016 STATE OF CALIFORNIA INDOOR LIGHTING CEC-NRCC-LTI-01-E (Revised 04/16 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE N RCC-LTI -01-E Indoor Lighting (Page 3 of 6) Project Name: Forever 21 - Mission Valley Date Prepared: 1/30/2018 E. Declaration of Required Certificates of Acceptance Declare by selecting yes for all of the Certificates that will be submitted. (Retain copies and verify forms are completed and signed.) YES NO Compliance Document/Title IZI 0 NRCA-LTI-02-A - Must be submitted for occupancy sensors and automatic time switch controls. 0 Field Inspector ❑ Q NRCA-LTI-03-A - Must be submitted for automatic daylight controls. 0 Field Inspector III 0 NRCA-LTI-04-A - Must be submitted for demand responsive lighting controls. 0 Field Inspector ❑ NRCA-LTI-05-A — Must be submitted for institutional tuning power adjustment factor (PAF). 0 Field Inspector 111 A Separate Lighting Schedule Must Be Filled Out for Conditioned and Unconditioned Spaces. Installed Lighting Power listed on this Lighting Schedule is only for: 0 CONDITIONED SPACE 0 UNCONDITIONED SPACE F. Indoor Lighting Schedule and Field Inspection Energy Checklist ❑ The actual indoor lighting power listed on the next 2 pages includes all installed permanent and planned portable lighting systems. ❑ When Complete Building Method is used for compliance, list each different type of luminaire on separate lines. ❑ When Area Category Method or Tailored Method is used for compliance, list each different type of luminaire by each different function area on separate lines ❑ Also include track lighting in schedule, and submit the track lighting compliance document (NRCC-LTI-05-E) when line -voltage track lighting is installed. CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance April 2016 STATE OF CALIFORNIA INDOOR LIGHTING CEC-NRCC-LTI-01-E (Revised 04/16 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE N RCC-LTI-01-E Indoor Lighting (Page 4 of 6) Project Name: Forever 21 - Mission Valley Date Prepared: 1/30/2018 G. Installed Portable Luminaires in Offices — Exception to Section 140.6(a) • This section shall be filled out ONLY for portable luminaires in offices (As defined in §100.1). All other planned portable luminaires shall be documented on next page of this compliance document. This section is used to determine if greater than 0.3 watts of portable lighting is planned for any office Fill out a separate line for each different office. Small offices that are typical (having the same general and portable lighting) may be grouped together. This allowance shall not be traded between offices having different lighting systems. • • Office Portable Luminaire Schedule Office Installed Portable Luminaire W/ft2 Office Location Field Inspector 1 2 3 4 5 6 7 8 9 10 Complete Luminaire Description (i.e., LED, under cabinet, furniture mounted direct/indirect) Watts per Luminaire Number of Luminaires Installed portable luminaire watts in this office (G02 x G03) Square feet of this office Watts per square foot (G04 / G05) IfGO6_5 0.3, enter zero; if G06 > 0.3, (G06-0.3) (G05 x G07) Identify Office area in which these portable luminaires are installed Pass Fail ❑ ❑ ❑ 0 ❑ 0 ❑ 0 • 0 2 Total installed portable luminaire watts that are greater than 0.3 W/ft2 office: Enter sum total of all pages into NRCC-LTI-01-E; Page 1 CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance April 2016 STATE OF CALIFORNIA INDOOR LIGHTING CEC-NRCC-LTI-01-E (Revised 04/16 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTI-01-E Indoor Lighting (Page 5 of 6) Project Name: Forever 21 - Mission Valley Date Prepared: 1/30/2018 A Separate Lighting Schedule Must Be Filled Out for Conditioned and Unconditioned Spaces. Installed Lighting Power listed on this Lighting Schedule is only for: 173 CONDITIONED SPACE 0 UNCONDITIONED SPACE H. Indoor Lighting Schedule and Field Inspection Energy Checklist Luminaire Schedule Installed Watts Location Field Inspector 1 01 02 03 04 05 06 07 08 How wattage was co determined -17 2 Complete Luminaire Description v 2 2 N o Name or a '-o Y o -E = Primary Function area in which (i.e, 3 lamp fluorescent troffer, a m V E c c, x Pass Fail Item Tag F32T8, one dimmable electronic ballast) g E ro o E a o z E _ v mo these luminaires are installed cJ O O m J O W .F L., 8 tot a ~ g 10A CL 10A Current Limiter 1,200.0 El 0 1 1,200 Retail Sales, Wholesale 0 0 13A CL 13A Current Limiter 1,560.0 El 0 5 7,800 Retail Sales, Wholesale 0 0 15A CL 15A Current Limiter 1,800.0 ❑ 0 3 5,400 Retail Sales, Wholesale 0 0 AF 50W MR16 Halogen 50.0 ❑ 0 2 100 Locker/Dressing Room 0 0 AQ 21W LED 21.0 0 RI 25 525 Locker/Dressing Room 0 0 AQ 21W LED 21.0 0 IZI 6 126 Corridor/Restroom/Support 0 0 AQ 21W LED 21.0 0 ❑ 4 84 Retail Sales, Wholesale 0 0 AT6C 70W CMH 75.0 El 0 3 225 Retail Sales, Wholesale 0 0 FB4D 40W LED 40.0 0 I I 3 120 Lounge, Recreation 0 0 INSTALLED WATTS PAGE TOTAL: 15,580 Enter sum total of all pages into NRCC-LTI-01-E; Page 2 CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance April 2016 STATE OF CALIFORNIA INDOOR LIGHTING CEC-NRCC-LTI-01-E (Revised 04/16 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE N RCC-LTI-01-E Indoor Lighting (Page 5 of 6) Project Name: Forever 21 - Mission Valley Date Prepared: 1/30/2018 A Separate Lighting Schedule Must Be Filled Out for Conditioned and Unconditioned Spaces. Installed Lighting Power listed on this Lighting Schedule is only for: D CONDITIONED SPACE 0 UNCONDITIONED SPACE H. Indoor Lighting Schedule and Field Inspection Energy Checklist Luminaire Schedule Installed Watts Location Field Inspector 1 01 02 03 04 05 06 07 08 Name or Item Tag Complete Luminaire Description (i.e, 3 lamp fluorescent troffer, F32T8, one dimmable electronic ballast) Watts per Luminaire How wattage was determined Number Luminaires Total Installed Watts in this area (F103xH05) Primary Function area in which these luminaires are installed Pass Fail CEC Default from NA8 According to §130.0(c) FB4D 40W LED 40.0 0 El 8 320 Commercial, Industrial Storage 0 0 Y1W 28W LED 28.0 0 El 14 392 Retail Sales, Wholesale 0 0 ❑ 0 0 0 0 0 0 0 ❑ 0 0 0 ❑ 0 0 0 ❑ 0 0 0 ❑ ❑ 0 0 ❑ ❑ ❑ ❑ INSTALLED WATTS PAGE TOTAL: 712 Enter sum total of all pages into NRCC-LTI-01-E; Page 2 CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance April 2016 STATE OF CALIFORNIA INDOOR LIGHTING CEC-NRCC-LTI-01-E (Revised 04/16 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE N RCC-LTI -01-E Indoor Lighting (Page 6 of 6) Project Name: Forever 21 - Mission Valley Date Prepared: 1/30/2018 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Ed Radziszewski Documentation Author Signature: {J% C� Company: TES Engineering Signature Date: Address: 25760 First Street CEA Certification Identification (if applicable): E22057 City/State/Zip: Westlake, Ohio 44145 Phone: 440.871.2410 • RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. I will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Ed Radziszewski Responsible Designer Signature: • Company : TES Engineering Date signed: 1/30/2018 Address: 25760 First Street License: E22057 City/State/Zip: Westlake, OH 44145 Phone: 440.871.2410 CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance April 2016 STATE OF CALIFORNIA INDOOR LIGHTING - LIGHTING CONTROLS CEC-NRCC-LTI-02-E (Revised 01/16 CALIFORNIA ENERGY COMMISSION co CERTIFICATE OF COMPLIANCE NRCC-LTI-02-E Indoor Lighting - Lighting Controls (Page 1 of 3) Project Name: Forever 21 - Mission Valley Date Prepared:1 /30/2018 A. Mandatory Lighting Control Declaration Statements (Indicate if the measure applies by checking yes or no below.) YES NO Control Requirements shall be controlled by self-contained lighting control devices which are certified to the Energy Commission according to the Title 20 Appliance Efficiency Regulations in accordance with Section 110.9. G•Lighting Lighting shall be controlled by a lighting control system or energy management control system in accordance with §110.9. An Installation Certificate shall be submitted in accordance with Section 130.4(b). One or more Track Lighting Integral Current Limiters shall be installed which have been certified to the Energy Commission in accordance with §110.9 and §130.0. Additionally, an Installation Certificate shall be submitted in accordance with Section 130.4(b). • G A Track Lighting Supplementary Overcurrent Protection Panel shall be installed in accordance with Section 110.9 and Section 130.0. Additionally, an Installation Certificate shall be installed in accordance with Section 130.4(b). Q•All lighting controls and equipment shall comply with the applicable requirements in §110.9 and shall be installed in accordance with the manufacturer's instructions in accordance with Section 130.1. Q All luminaires shall be functionally controlled with manually switched ON and OFF lighting controls in accordance with Section 130.1(a). • General lighting shall be separately controlled from all other lighting systems in an area. Floor and wall display, window display, case display, ornamental, and special effects lighting shall each be separately controlled on circuits that are 20 amps or less. When track lighting is used, general, display, ornamental, and special effects lighting shall each be separately controlled; in accordance with Section 130.1(a)4. P • D The general lighting of any enclosed area 100 square feet or larger, with a connected lighting load that exceeds 0.5 watts per square foot shall meet the multi-level lighting control requirements in accordance with Section 130.1(b). II 0 All installed indoor lighting shall be equipped with controls that meet the applicable Shut -OFF control requirements in Section 130.1(c). R Q' Lighting in all Daylit Zones shall be controlled in accordance with the requirements in Section 130.1(d) and daylit zones are shown on the plans. • Lighting power in buildings larger than 10,000 square feet shall be capable of being automatically reduced in response to a Demand Responsive Signal in accordance with Section 130.1(e). Ef Before an occupancy permit is granted for a newly constructed building or area, or a new lighting system serving a building, area, or site is operated for normal use, indoor lighting controls serving the building, area, or site shall be certified as meeting the Acceptance Requirements for Code Compliance in accordance with Section 130.4.(a). The controls required to meet the Acceptance Requirements include automatic daylight controls, automatic shut -OFF controls, and demand responsive controls. . CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance January 2016 STATE OF CALIFORNIA INDOOR LIGHTING — LIGHTING CONTROLS CEC-NRCC-LTI-02-E (Revised 01/16 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE N RCC-LTI-02-E Indoor Lighting - Lighting Controls (Page 2 of 3) Project Name: Forever 21 - Mission Valley Date Prepared: 1/30/2018 A separate document must be filled out for Conditioned and Unconditioned Spaces. This page is used only for the following: 12 CONDITIONED SPACES 0 UNCONDITIONED SPACES B. Mandatory and Prescriptive Indoor Lighting Control Schedule, PAF Calcu ation, and Field Inspection Checklist Lighting Control Schedule Standards Complying With 1 (✓ all that apply, or enter 'E' if Exempted) PAF Credit Calculation 2 v u -a c ai ro L Q cu - v U C Q713 1— o 0 d Q73 4J OL o L) Q a o - E' v X Y 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 Location in Building Type/Description of Lighting Control (i.e.: occupancy sensor, automatic time switch, dimmer, automatic daylight, etc...) # of Units v o w, 1 0 0 4, -o 0 coo, "Cu' 0 7 0 WI -a 0 fl) a co LI - Restrooms 1 D I! A • • • • o ❑ ❑ Stock Room 1 PPR • • • • e ❑ ❑ Break Room 1 r 1 • • • s ❑ ❑ Corridor 1 c GU ■ MINN / ❑ ❑ Corridor Sales Area Control 1 k [I [i ■ ■ ■ ■ 100 ■ ■ ■ ■ ■ ■ ■ ❑ ❑ Control Credit PAGE TOTAL (Sum of Column 13): 0 IF MULTIPLE PAGES ARE USED, ENTER SUM TOTAL OF Control Credit for all pages HERE (Sum of all Column 13): 0 Enter Control Credit total into NRCC-LTI-01-E; Page 1. 1. §130.1(a) = Manual area controls; §130.0(b) = Multi Level; §130.1(c) = Auto Shut -Off; §130.1(d) = Mandatory Daylight; §130.1(e) = Demand Responsive; §140.6(d) _ Additional lighting controls installed to earn a PAF; §140.6(d) = Prescriptive Secondary Sidelit Daylight Controls. 2. Check Table 140.6-A for correct Factor. PAFs shall not be traded between conditioned and unconditioned spaces. As a condition to earn a PAF, an Installation Certificate is also required to be filled out, signed, and submitted. CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance January 2016 STATE OF CALIFORNIA INDOOR LIGHTING - LIGHTING CONTROLS CEC-NRCC-LTI-02-E (Revised 01/16 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE N RCC-LTI-02-E Indoor Lighting - Lighting Controls (Page 3 of 3) Project Name: Forever 21 - Mission Valley Date Prepared: 1/30/2018 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Ed Radziszewski Documentation Author Signature: /" Company: TES Engineering Signature Date: 1/30/2018 Address: 25760 First Street CEA Certification Identification (if applicable): E22057 City/State/Zip: Westlake, Ohio 44145 Phone: 440.871.2410 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. I will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Ed Radziszewski Responsible Designer Signature: Company : TES Engineering Date Signed: 1 /30/2018 Address: 25760 First Street License: E22057 City/State/Zip: Westlake, OH 44145 Phone" 440.871.2410 CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance January 2016 STATE OF CALIFORNIA INDOOR LIGHTING POWER ALLOWANCE CEC-NRCC-LTI-03-E (Revised 04/16 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTI-03-E Certificate of Compliance - Indoor Lighting Power Allowance (Page 1 of 4) Pro'ectName' Forever 21 - Mission Valley Date Prepared: 1/30/2018 A separate page must be filled out for Conditioned and Unconditioned Spaces. This page is only for: ® CONDITIONED spaces 0 UNCONDITIONED spaces A. SUMMARY TOTALS OF LIGHTING POWER ALLOWANCES • If using Complete Building Method for compliance, use only the total in column (a) as total allowed building watts. • If using Area Category Method, Tailored Method, or a combination of Area Category and Tailored Method for compliance, use only the total in column (b) as the total allowed building watts 02 (a) 03 (b) 01 Complete Building Method Allowed Watts. Documented in section B of NRCC-LTI-03-E (below on this page) TYPE OF BUILDING (From §140.6 Table 140.6-B) WATTS PER ft2 X 02 Area Category Method Allowed Watts. Documented in section C-1 of NRCC-LTI-03-E (below on this page) = ALLOWED WATTS 1,397 03 Tailored Method Allowed Watts. Documented in section A of NRCC-LTI-04-E 15,256 TOTAL ALLOWED BUILDING WATTS. Enter number into correct cell on NRCC-LTI-01, Page 2, Row 1 Total Area: 16,653 • Check here if building contains both conditioned and unconditioned areas. B. COMPLETE BUILDING METHOD LIGHTING POWER ALLOWANCE 01 02 1,397 03 0 04 TYPE OF BUILDING (From §140.6 Table 140.6-B) WATTS PER ft2 X COMPLETE BLDG. AREA = ALLOWED WATTS Total Area: Total Watts. Enter Total Watts into section A, row 1 (Above on this page) C -1 AREA CATEGORY METHOD TOTAL LIGHTING POWER ALLOWANCES Watts Total from section C-2. 1,397 Total from section C-3. 0 Total Watts. Enter Total Watts into section A, row 2 (Above on this page). 1,397 For Alterations Only — Reduced lighting power option (Total Allowed Watts x 0.85). Enter this value into section A, row 2 if using this option. CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance April 2016 STATE OF CALIFORNIA INDOOR LIGHTING POWER ALLOWANCE CEC-NRCC-LTI-03-E (Revised 04/16 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE N RCC-LTI-03-E Certificate of Compliance - Indoor Lighting Power Allowance (Page 2 of 4) Project Name: Forever 21 - Mission Valley Date Prepared: 1/30/2018 A separate page must be filled out for Conditioned and Unconditioned Spaces. This page is only for: E CONDITIONED spaces 0 UNCONDITIONED spaces C -2 AREA CATEGORY METHOD GENERAL LIGHTING POWER ALLOWANCE ❑ Do not include portable lighting for offices. Portable lighting for offices shall be documented only in Section G of NRCC-LTI-01-E. ❑ Separately list lighting for each primary function area as defined in §100.1 of the Standards. 01 AREA CATEGORY (From §140.6 Table 140.6-C) Location in Building Primary Function Area per Table 140.6-C Fitting Rooms Stock Room Toilets/Corridor Break Room Locker/Dressing Room Commercial, Industrial Storage Corridor/Restroom/Support Lounge, Recreation 02 WATTS PER ft2 0.70 0.60 0.60 0.90 X 03 AREA (ft2) 745 845 302 208 TOTALS 2,100 04 ALLOWED WATTS 522 507 181 187 Enter sum total Area Category allowed watts into section C-1 of NRCC-LTI-03-E (this compliance document) 1,397 WATTS CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance April 2016 LL) IV > / 3 § % — / 0 / 0 ) _ \ m n 0 « = e m a / 7 } §_ k / � k \ $ / / \ 0 CL * ± e 7 0 / <0 / ( / % 7 tel 0 0 i / (0 0 } a2(/ / ƒ \ / 0 \ \ E 2 2 s $ 2 o 0 ® o 0 o 7 n 0 7 M / a //0-§ n o _ � m & a o \ 9- \ ( / 0 — S / % o , H 0 0 \ m o 0 • \ & > > & ƒ m \ ) -1 E § » M 0- \ g CU e a / -0 \ / Q 0 E = a n -< M \ / I CL % 0 2 0 7 0 s 0 f 2 n 2 071 M •• m \ 5. ® ® R \ > / \ / \ r- « / $ / o 2 3 f k » f o a 713 n 0 c / 2 § } i®( £ 0 } � f » 5- 0. E /CL E ƒ 2 0 0 R 2 } » P- o 0 § nl a 0 0 E > 0 / o \ 0 / / } ƒ ƒ \ \ i \ \ / O 0 / o- 0 / k E 0 0 r 0 i / -a ( 2 / / -1 0 2 3 0 } / / 0 / 2 L. OZ/OC/ i- :paJedaid alep 7-3 (0 0 � 3-£0-111-DDHN STATE OF CALIFORNIA INDOOR LIGHTING POWER ALLOWANCE CEC-NRCC-LTI-03-E (Revised 04/16 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE N RCC-LTI-03-E Certificate of Compliance - Indoor Lighting Power Allowance (Page 4 of 4) Project Name: Forever 21 - Mission Valley Date Prepared: 1/30/2018 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Ed Radziszewski Documentation Author Signatur ./1,7;401 Company: TES Engineering N//A Signature Date: 1/30/2018 Address: 25760 First Street CEA Certification Identification (if applicable): E22057 City/State/Zip: Westlake, Ohio 44145 Phone: 440.871.2410 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. I will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Ed Radziszewski Responsible Designer Signature: Company: TES Engineering Date Signed: 1 �30/2�1 Address: 25760 First Street license: E22057 City/State/Zip: Westlake, OH 44145 Phone: 440.871.2410 CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance April 2016 STATE OF CALIFORNIA TAILORED METHOD CEC-NRCC-LTI-04-E (Revised 01/16 CERTIFICATE OF COMPLIANCE CALIFORNIA ENERGY COMMISSION NRCC-LTI-04-E Indoor Lighting — Tailored Method (Page 1 of 7) Pro;ectName: Forever 21 - Mission Valley Date Prepared: 1/30/2018 Complete separate documents for Conditioned and Unconditioned Spaces. This page is used to document: ❑ CONDITIONED SPACES 0 UNCONDITIONED SPACES A. TAILORED METHOD LIGHTING POWER ALLOWANCE SUMMARY 01 General lighting power (Building Total from Section B of NRCC-LTI-04-E) 01 6,685 02 General lighting power special function areas (Building Total from Section C of NRCC-LTI-04-E) 02 0 03 Additional "use it or lose it" lighting power (Watts listed in each of these cells shall be identical to total allowed watts determined in Section D of NRCC-LTI-04-E. 07 Wall Display from Section 0-1 Combined Floor Display and Task Lighting from Section D-2 Combined Ornamental and Special Effects Lighting from Section D-3 ROOM NUMBER Very Valuable Merchandise from Section D-4 ILLUMINANCE VALUE (LUX) 0 + 8,571 + 0 + 0 = 03 8,571 04 Total Allowed Watts using Tailored Method (add lines 1, 2 and 3) 04 15,256 B. TAILORED METHOD ALLOWED GENERAL LIGHTING POWER FROM TABLE 140.6-D 01 02 03 04 05 06 07 07 ROOM NUMBER PRIMARY FUNCTION AREA ILLUMINANCE VALUE (LUX) ROOM CAVITY RATIO ALLOWED LPD FLOOR AREA ALLOWED WATTS (B05 x B06) FLOOR AREA Retail Sales, Wholesale 400 0.64 0.78 8,571 6,685 PAGE TOTAL 6,685 If multiple pages are used, enter building total here 6,685 C. TAILORED METHOD ALLOWED GENERAL LIGHTING POWER FOR SPECIAL FUNCTION AREAS ACCORDING TO § 140.6(c)3H 0 This section shall be used to determine allowed general lighting power ONLY for the following primary function areas: Exercise Center, Gymnasium; Medical and Clinical Care; Police Stations and Fire Stations; Public rest areas along state and federal roadways; other primary function areas that are listed in neither Table 140.6-C nor Table 140.6-D 01 02 03 04 05 06 07 ROOM NUMBER PRIMARY FUNCTION AREA ILLUMINANCE VALUE (LUX) ROOM CAVITY RATIO ALLOWED LPD FLOOR AREA ALLOWED WATTS (COS x CO6) PAGE TOTAL If multiple pages are used, enter building total here 0 CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance January 2016 STATE OF CALIFORNIA TAILORED METHOD CEC-NRCC-LTI-04-E (Revised MM/YY CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE N RCC-LTI-04-E Indoor Lighting—Tailored Method (Page 2 of 7) Project Name: Forever 21 - Mission Valley Date Prepared: 1/30/2018 Complete separate documents for Conditioned and Unconditioned Spaces. This page is used to document: 0 CONDITIONED SPACES 0 UNCONDITIONED SPACES D. TAILORED METHOD ADDITIONAL "USE IT OR LOSE IT" LIGHTING POWER ALLOWANCES ❑ Use this section to document and calculate additional lighting power for wall display, floor display, task, ornamental, special effects, or very valuable display case lighting. ❑ The additional lighting power allowance shall be the smaller of the allowed lighting power or the actual lighting power used. ❑ These additional lighting power allowances shall not be available when using §140.6(c)3H to determine the general lighting power allowance, when using the Complete Building Method, or for any areas using the Area Category Method. D-1. ADDITIONAL ALLOWED LIGHTING POWER FOR WALL DISPLAY LIGHTING ❑ Floor displays shall not qualify for the wall display lighting power allowance. ❑ Qualifying wall lighting complies with the applicable requirements in §140.6(c)3I. 01 02 03 04 05 06 07 08 09 10 11 Primary Function Area ALLOTTED WATTS DESIGN WATTS Wall Display Length in (Linear Feet) Wall Display Power (W/lin foot) Allotted Watts (02 x 03) Luminaire Code Mounting Height Mounting Height Factor Watts per Luminaire # Luminaires Design Watts (07 x 08 x 09) Allowed Watts (smaller of 04 or 10) < 12 feet 1.00 s, 12 feet to 0.87 >_ 16 feet 0.77 Total for this Primary Function Area: < 12 feet 1.00 _ 12 feet to 0.87 z 16 feet 0.77 Total for this Primary Function Area: <12feet 1.00 12 feet to 0.87 16 feet 0.77 Total for this Primary Function Area: < 12 feet 1.00 12 feet to 0.87 a 16 feet 0.77 Total for this Primary Function Area: Sum total power for wall display lighting for all function areas: 0 CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance January 2016 1 h i Vr �,r�LIrVKNIA TAILORED METHOD CEC-NRCC-LTI-04-E (Revised MM/YY CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE N RCC-LTI-04-E Indoor Lighting — Tailored Method (Page 3 of 7) Pro;e"ame.Forever 21 - Mission Valley Date Prepared. 1/30/2018 Complete separate documents for Conditioned and Unconditioned Spaces. This page is used to document: I CONDITIONED SPACES 0 UNCONDITIONED SPACES D-2. ADDITIONAL ALLOWED LIGHTING POWER FOR COMBINED FLOOR ❑ Displays that are installed against a wall shall not qualify for the floor ❑ Lighting internal to display cases shall be counted EITHER as floor display ❑ Additional allowed power for floor display lighting, and additional allowed combination of both. For floor areas qualifying for both floor display the allowance shall not be additive. ❑ Qualifying floor display lighting complies with the applicable provision ❑ Additional allowed power for a combination of floor display lighting and tasks having illuminance recommendations that appear in the Tenth square footage of floor display or the square footage of task areas shall tasks, such as floor areas designated as a path of egress, shall not be DISPLAY AND TASK LIGHTING display lighting power allowances. lighting in accordance with §140.6(c)3J; or as very valuable display case lighting in accordance with §140.6(c)3Liii and iv. power for task lighting, may be used by qualifying floor display lighting systems, qualifying task lighting systems, or a and task lighting power allowances, the additional allowed power shall be used only once for the same floor area, so that in §140.6(c)3J(v and vi). task lighting shall be available only for (I) floors having floor displays; or (II) floors not having floor displays but having Edition of the IES Lighting Handbook and that are higher than the general lighting level in column 2 of TABLE 140.6-D. The be determined in accordance with §140.6(c)3C and D, except that any floor area designed to not have floor displays or included for the floor display allowance. 01 02 03 04 05 06 07 08 09 10 11 ALLOTTED WATTS DESIGN WATTS Primary Function Area Square Feet of Area Lighting Power (W/ft2) Allotted Watts (02 x 03) Luminaire Code Mounting Height Mounting Height Factor Watts per Luminaire # Luminaires Design Watts (07 x 08 x 09) Allowed Watts (smaller of 04 or 10) <12feet 1.00 Sales Area 8,571 1.00 8,571 15A CL 12 feet to 0.87 1,800.0 3 4,696 >_ 16 feet 0.77 Total for this Primary Function Area: 8,571 <12feet 1.00 Sales Area 8,571 1.00 8,571 13A CL 12 feet to 0.87 1,560.0 5 6,783 >_ 16 feet or higher 0.77 Total for this Primary Function Area: 8,571 < 12 feet 1.00 10A CL 12 feet to 0.87 1,200.0 1 1,043 Sales Area 8,571 1.00 8,571 z 16 feet or higher 0.77 Total for this Primary Function Area: 8,571 Sum total power for combined floor display and task lighting: 8,571 CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance January 2016 STATE OF CALIFORNIA TAILORED METHOD ' CEC-NRCC-LTI-04-E (Revised MM/YY CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE N RCC-LTI-04-E Indoor Lighting—Tailored Method (Page 4 of 7) Project Name: Forever 21 - Mission Valley Date Prepared: 1/30/2018 Complete separate documents for Conditioned and Unconditioned Spaces. This page is used to document: Gt CONDITIONED SPACES 0 UNCONDITIONED SPACES D-3. ADDITIONAL ALLOWED LIGHTING POWER FOR COMBINED ORNAMENTAL AND SPECIAL EFFECTS ❑ Qualifying ornamental lighting includes luminaires such as chandeliers, sconces, lanterns, neon and cold cathode, light emitting diodes, theatrical projectors, moving lights, and light color panels when any of those lights are used in a decorative manner that does not serve as display lighting or general lighting. ❑ Special effects lighting is defined as lighting installed to give off luminance instead of providing illuminance. ❑ There is no mounting height multiplier for ornamental or special effects lighting ❑ Additional allowed power for ornamental and special effects lighting may be used only for qualifying lighting systems. For floor areas qualifying for both ornamental and special effects lighting power allowances, the additional allowed power shall be used only once for the same floor area, so that the allowance shall not be additive. 01 02 03 04 05 06 07 08 09 Primary Function Area ALLOTTED WATTS DESIGN WATTS Square Feet of Area Lighting Power (W/ft2) Allotted Watts (02 x 03) Luminaire Code or Description (rows below accommodate 3 layers per function area) Watts per Luminaire # Luminaires Design Watts (06 X 07) Allowed Watts (smaller of 04 or Total for 08) 1 3 Total ornamental/special effects lighting for this primary function area: 1 2 3 Total ornamental/special effects lighting for this primary function area: 1 2 3 Total ornamental/special effects lighting for this primary function area: 1 2 3 Total ornamental/special effects lighting for this primary function area: Sum total allowed watts for ornamental and special effects lighting: 0 CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance January 2016 a i ri t yr uk\uvoRNIA TAILORED METHOD CEC-NRCC-LTI-04-E (Revised MM/YY CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE N RCC-LTI-04-E Indoor Lighting — Tailored Method (Page 5 of 7) Project Name: Forever 21 - Mission Valley Date Prepared: 1/30/2018 Complete separate documents for Conditioned and Unconditioned Spaces. This page is used to document: G2 CONDITIONED SPACES 0 UNCONDITIONED SPACES D-4. ADDITIONAL ALLOWED LIGHTING POWER FOR VERY VALUABLE DISPLAY CASE LIGHTING ❑ Lighting internal to display cases shall be counted EITHER as floor display lighting in accordance with §140.6(c)3J; or if qualifying, as very valuable display case lighting in accordance with §140.6(c)3Liii and iv. ❑ Case lighting is lighting of small art objects, artifacts, or valuable collections which involves customer inspection of very fine detail from outside of a glass enclosed display case. ❑ To qualify for this allowance, case shall contain jewelry, coins, fine china, fine crystal, precious stones, silver, small art objects or artifacts, and/or valuable collections the display of which involves customer inspection of very fine detail from outside of a locked case. ❑ This allowance is available only for display cases in retail merchandise sales, museum, and religious worship areas. 0 Any floor area designed to not have very valuable display case lighting shall not be included for this allowance. ❑ A mounting height multiplier is not available. 01 02 03 04 05 06 07 08 09 10 WATTS PER SQUARE FOOT OF QUALIFYING WATTS PER SQUARE FOOT OF QUALIFYING FLOOR AREA DISPLAY CASE AREA ALLOWED Allotted Allotted ACTUAL WATTS Square Feet of Allowed Watts Square Feet of Allowed Watts INSTALLED (SMALLEST OF Primary Function Area Description of Display Case Floor Area W/ft2 (03 x 04) Display Case (W/ft2) (06 x 07) WATTS 05, 08, or 09) 0.8 12.0 0.8 12.0 0.8 12.0 0.8 12.0 0.8 12.0 0.8 12.0 0.8 12.0 0.8 12.0 0.8 12.0 0.8 12.0 0.8 12.0 Sum total allowed watts for very valuable display case lighting: 0 CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance January 2016 STATE OF CALIFORNIA TAILORED METHOD CEC-NRCC-LTI-04-E (Revised MM/YY CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTI-04-E Indoor Lighting—Tailored Method (Page 6 of 7) Project Name: Forever 21 - Mission Valley Date Prepared: 1 /30/2018 ROOM CAVITY RATIO (RCR) WORKSHEET RECTANGULAR SPACES 01 02 03 04 05 06 Room Number Task/Activity Description Room Length (L) (ft) Room Width (W) (ft) Room Cavity Height (H) (ft) RCR 5 x H x (L+W) / (L x W) NON -RECTANGULAR SPACES 01 02 03 04 05 06 Room Number Task/Activity Description Room Area (A) (ft2) Room Perimeter (P) (ft) Room Cavity Height (H) (ft) RCR 2.5 x H x P / A Sales Area Retail Sales, Wholesale 8,571.0 400.0 5.5 0.64 CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance January 2016 STATE OF CALIFORNIA TAILORED METHOD CEC-NRCC-LTI-04-E (Revised MM/YY) CERTIFICATE OF COMPLIANCE CALIFORNIA ENERGY COMMISSION NRCC-LTI-04-E Indoor Lighting — Tailored Method (Page 7 of 7) Project Name: Date Prepared: DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Ed RadZISZeWSitl Documentation Author Signatur J Company: TES Engineering Signature Date: 1/30/2018 Address: 25760 First Street CEA Certification Identification (if applicable): E22057 City/State/Zip: Westlake, Ohio 44145 Phone: 440.871.2410 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. I will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building o ner at occupancy. Responsible Designer Name: Ed Radziszewski Responsible Designer Signature:j is _i-...." Company : TES Engineering Date signed: 1/30/21 : / Address: 25760 First Street License: E22057 City/State/Zip: Westlake, OH 44145 Phone: 440.871.2410 CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance January 2016 STATE OF CALIFORNIA LINE -VOLTAGE TRACK LIGHTING WORKSHEET CEC-NRCC-LTI-05-E (Revised 01/16 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE N RCC-LTI-05-E Indoor Lighting — Line -Voltage Track Lighting Worksheet (Page 1 of 2) Project Name: Forever 21 - Mission Valley Date Prepared: 1/30/2018 There are four different methods available for determining how many watts of line -voltage track, or line -voltage busway, has been installed. One or more methods may be used to determine how many watts of line -voltage track, or line -voltage busway, has been installed. Use this worksheet to separately calculate the input wattage for each system. Separately enter each row of this worksheet into the Luminaire Schedule in Section H of NRCC-LTI-01-E Method 1 is the only option available for determining wattage for track or busway rated for more than 20 amperes ❑ A. METHOD 1— VOLT-AMPERE (VA) RATING OF THE BRANCH CIRCUIT(S) 01 02 BRANCH CIRCUIT NAME OR ID VOLT-AMPERE (VA) RATING OF THE BRANCH CIRCUIT 05 06 Track or Name # Linear Feet of Track (W/LF) B02 x B03 (W) ❑ B. METHOD 2 — USE THE HIGHER OF 45 WATTS PER LINEAR FOOT OF TRACK OR TOTAL RATED WATTAGE OF ALL LUMINAIRES 01 02 03 04 05 06 Track or Name # Linear Feet of Track (W/LF) B02 x B03 (W) Total Rated Wattage of All Luminaires Larger of B04 or 605 Larger of C04 or CO5 45 12.5 45 12.5 45 12.5 ❑ C. METHOD 3 — USE THE HIGHER OF: 12.5 WATTS / LINEAR FOOT OF TRACK — OR VA RATING OF INTEGRAL CURRENT LIMITER 0 Only integral current limiters which are certified to the Energy Commission shall be recognized by the Standards. ❑ This method shall not be recognized if an Installation Certificate is not submitted. 01 02 03 04 05 06 Track or Name # Linear Feet of Track (W/LF) CO2 x CO3 (W) VA Rating of Integral Current Limiter Larger of C04 or CO5 12.5 12.5 12.5 0 D. METHOD 4 - DEDICATED TRACK LIGHTING SUPPUMENTARY OVERCURRENT PROTECTION PANEL 0 This method shall not be recognized if an Installation Certificate is not submitted. lZI This method shall be used only for line -voltage track lighting, and shall not be recognized for any other lighting systems. If any other lighting systems or devices are installed, the supplementary overcurrent protection panel shall not be recognized for compliance with the Standards 01 02 03 04 NAME OR ID Voltage of the Branch Circuit Sum of the Ampere Rating of all Devices Installed in the Panel Wattage = Sum of the Ampere Ratings of all of the Devices Times the Branch Circuit Voltage (D02 x D03) CLP 120 125 15,000 DOCUMENTATION AUTHOR'S DIECLARATION STATEMENT CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance January 2016 STATE OF CALIFORNIA LINE -VOLTAGE TRACK LIGHTING WORKSHEET CEC-NRCC-LTI-05-E (Revised 01/16 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTI-05-E Indoor Lighting — Line -Voltage Track Lighting Worksheet (Page 2 of 2) Project Name: Forever 21 - Mission Valley Date Prepared.1 /30/2018 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Ed Radziszewski Documentation Author Signatur 1► Company: TES Engineering Signature Date:1/30/2018 Address: 25760 First Street CEA Certification Identification (if applicable): E22057 City/State/Zip: Westlake, Ohio 44145 Phone:440.871.2410 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. I will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provide to the .u' ding own -r at occupancy. Responsible Designer Name: Ed Radziszewski Responsible Designer gnergnaure: Company : TES Engineering Date signed: 1/30/201 / / Address: 25760 First Street License: E22057 City/State/Zip: Westlake, OH 44145 Phone: 440.8712410 CA Building Energy Efficiency Standards - 2016 Nonresidential Compliance January 2016 i Harbor Consulting Engineers, Inc. MEMORANDUM 30 April 2018 To: Mr. Bill Rambo Permit Technician City of Tukwila Department of Community Development RE: Plan Review Comments Response for Permit Application D18-0093 RILEY ROSE, LLC — 467 SOUTHCENTER MALL Harbor Consulting Engineers, Inc. has reviewed your plan check letter dated 23 April 2018 for the following structural related items. Our responses are italicized and follow each comment as noted below. BUILDING REVIEW NOTES 1. Please provide the necessary statement of special inspections as required for the tenant improvement. Please see amended general structural notes on sheet 5-1 for special inspection requirements for the project as requested. A table of structural engineer required special inspection items is indicated in tabular form on the project documents sheet S-1. 2. Engineer's structural calculations front sheet and all engineer's plan sheets shall have stamp and signature with "Date" of that signature. See general note above. All structural drawings and structural calculations have the date added in close proximity to the engineer's seal, as requested. This completes our plan check review responses. CORRECTION Please call me if you have any questions or if our office can be of further assistance„ LTR# HARBO 2 T NG ENGINEERS, INC.— - Darren S. Johnston, P.E., S.E. Senior Project Manager bi f3-ooa3 1 of 1 RECEIVE CITY OF TUKWILA APR 30 2016 F.,37:iCENTER 3316 Fuhrman Avenue East Suite 250 • Seattle, WA 98102 • Telephone 206.709.2397 • Facsimile 206.709.2398 April 23, 2018 i City of Tukwila Department of Community Development ABEL LOPEZ 3880 N MISSION ROAD LOS ANGELES, CA 90031 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D 18-0093 RILEY ROSE, LLC - 467 SOUTHCENTER MALL Dear ABEL LOPEZ, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. 1 have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. "New revised" plan sheets shall be the same size sheets as those previously submitted.) "STAMP AND SIGNATURES" (If applicable) For Engineers: "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient (WAC 196-23-010 & 196-23-020). Architects: "date" only not required (WAC 308-12-081). (BUILDING REVIEW NOTES) 1. Please provide the necessary statement of special inspections as required for the tenant improvement. 2. Engineer's structural calculations front sheet and all engineer's plan sheets shall have stamp and signature with "Date" of that signature. See general note above. Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Sincerely, Bill Rambo Permit Technician File No. D 18-0093 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 HERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-oo93 PROJECT NAME: RILEY ROSE, LLC SITE ADDRESS: 467 SOUTHCENTER MALL Original Plan Submittal DATE: 09/05/18 Revision # before Permit Issued Response to Correction Letter # _X Revision # 1 after Permit Issued DEPARTMENTS: M PCS gliUlli Building Division Raj Public Works kM kp Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: DATE: 0/06/18 Not Applicable n Structural Review Required (no approval/review required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: 10/04/18 ❑ Approved with Conditions n Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0093 DATE: 04/30/18 PROJECT NAME: RILEY ROSE SITE ADDRESS: 467 SOUTHCENTER MALL Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: q\qiBuilding Division Public Works Fire Prevention Structural n Planning Division Permit Coordinator or PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 05/01/18 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required DUE DATE: 05/29/18 n Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 \PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D18-0093 DATE: 04/02/18 PROJECT NAME: RILEY ROSE, LLC SITE ADDRESS: 467 SOUTHCENTER MALL X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Aavl cows?. I-LiNt9 Building Division ip Public Works A-04 Atet, Fire Prevention Structural ) 0/4-14-14-16 Planning Division IP ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 04/03/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05/01/18 Approved ❑ Approved with Conditions Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: t 6 Departments issued corrections: Bldg Fire 0 Ping 0 PW ❑ Staff Initials: 12/18/2013 PROJECT NAME: SITE ADDRESS: f � _/ G I PERMIT NO: DI r 00n Ars 111,11,1 ORIGINAL ISSUE DATE: 5 1 REVISION LOG REVISION NO. Summary of Revision: DATE RECEIVED (f) STAFF INALS .. l ISSUED DATE STAFF INITIALS_ Received by: div T B 0 REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) Date: r \ City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. August 30, 2018 Plan Check/Permit Number: D18-0093 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # X❑ Revision # 01 after Permit is Issued (on drawing title block Revision 3: Instruction Bulletin 01) (on drawing title block Revision 4: Instruction Bulletin 02) ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: Riley Rose, LLC Project Address: 467 Southcenter Mall Contact Person: Abel Lopez Phone Number: (213) 765-2978 Summary of Revision: Landlord, Westfield, during start of construction requested that a high ceiling be installed instead of having an open to structure design look. High ceiling installed at 14'-0" and at 12'-0"above finish floor level. Drawing sheets A110, A210, A400, and A410 have been updated to showing detail for suspended gypsum board system. Sheet M110 has also been updated to show location of air registers at high ceiling. R CITY OF TUKWILA 0 6 2201 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date oinion rAN Received at the City of Tukwila Permit Center by:r ❑ Entered in TRAKiT on W:\Fermit Center\Tenplates\Forms\Revision Submittal Formdoc Revised: August 2015 '`! City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: April 30, 2018 Plan Check/Permit Number: DI 8-0093 ❑ Response to Incomplete Letter # ▪ Response to Correction Letter # I ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: Riley Rose Project Address: 467 Southcenter Mall, Space #1545 Contact Person: Abel Lopez Summary of Revision: 1. Special inspection shown on sheet S1. Phone Number: (213) 765-2978 2. Structural calculations submitted with signed seal date. RECEIVED CITY OF TUKWILA APR 3 0 2018 PERMIT CENTER Sheet Number(s): S1, S2, S3, AND STRUCTURAL CALCULATIONS. "Cloud" or highlight all areas of revision including date o revision Received at the City of Tukwila /Permit Center by: Entered in TRAKiT on 1 l ' t e W: Permit Center\Templates\Forn \Revision Submittal Fonndoc Revised: August 2015 JAMES E JOHN CONST CO INC Washington State Department of /0 Labor & Industries 1lorne Espanol Contact Safety & Health Claims & Insurance Search L&I Page 1 of 2 P A -Z. Index Help My 1..&1 Workplace Rights Trades & Licensing JAMES E JOHN CONST CO INC Owner or tradesperson Principals Foroud, Cameron R, PRESIDENT JOHN, JAMES E, DIRECTOR LINDGREN, SCOTT K, SECRETARY (End: 10/14/2015) HINNEN, ROBERT A, TREASURER (End: 10/14/2015) Doing business as JAMES E JOHN CONST CO INC WA UBI No. 600 491 465 1701 SE COLUMBIA RIVER DR VANCOUVER, WA 98661 360-696-0837 CLARK County Business type Corporation Governing persons JAMES E. JOHN JAMES ALLEN JOHNSON; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. JAMESEJ173MM Effective — expiration 07/14/1983-11/07/2019 Bond TRAVELERS CAS & SURETY CO Bond account no. 042S103598702BCM Active. Meets current requirements. $12,000.00 Received by L&I Effective date 10/22/2001 09/13/2001 Expiration date Until Canceled Insurance National Fire Ins of Hartford $1,000,000.00 Policy no. 6050055667 Received by L&I Effective date 09/27/2017 10/01/2017 Expiration date Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600491465&LIC=JAMESEJ173MM&SAW= 5/31/2018 JAMES E JOHN CONST CO INC 10/01/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 461,470-00 ............................... Doing business as JAMES E JOHN Estimated workers reported Quarter 1 of Year 2018 "21 to 30 Workers" L&I account contact T5 / MELISSA VEST (360)902-5613 - Email: VESM235@lni.wa.gov Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 08/01/2013 Inspection no. 316836527 Location 19800 Hwy 99 Lynnwood, WA 98036 No violations Page 2 of 2 J Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600491465&LIC=JAMESEJ 173MM&SAW= 5/31/2018