HomeMy WebLinkAboutPermit M18-0001 - ROSS RESIDENCE - DUCTLESS HEAT PUMP SYSTEMROSS RESIDENCE
4904 S 164 ST
MI 8-0001
Parcel No:
Address:
Project Name:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
MECHANICAL OTC PERMIT
5379800390 Permit Number: M18-0001
4904 S 164TH ST
ROSS RESIDENCE
Issue Date: 1/3/2018
Permit Expires On: 7/2/2018
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
License No:
Lender:
Name:
Address:
ROSS KIMBERLY D
4904 S 164TH , TUKWILA, WA, 98188
RICK OWEN
18318 SE 259 CT, COVINGTON, WA,
98042
PATRIOT HEATING AND A/C INC
18318 SE 259TH CT, COVINGTON,
WA, 98042-5052
PATRIHA936CN
Phone: (206) 510-2865
Phone: (253) 631-0601
Expiration Date: 2/15/2019
DESCRIPTION OF WORK:
INSTALL A FON HEAD MINI SPLIT DUCTLESS HEAT PUMP SYSTEM & REMOVE OLD OIOL FURNACE
Valuation of Work: $9,000.00
Type of Work: REPLACEMENT
Fuel type: ELECT
Fees Collected: $256.39
Electrical Service Provided by: PUGEST SOUND ENERGY
Water District: HIGHLINE
Sewer District: VALLEY VIEW
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
2015
2015
2015
2015
2015
National Electrical Code:
WA Cities Electrical Code:
WAC 296-46B:
WA State Energy Code:
2017
2017
2017
2015
Permit Center Authorized Signature:
Date: �� 8
r
\ J
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature:
Print Name:
Date:
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***MECHANICAL PERMIT CONDITIONS***
2: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center (206/431-3670).
3: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
4: Manufacturers installation instructions shall be available on the job site at the time of inspection.
5: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired
appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces:
Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms.
6: Equipment and appliances having an ignition source and located in hazardous locations and public garages,
PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be
elevated such that the source of ignition is not less than 18 inches above the floor surface on which the
equipment or appliance rests.
7: Type 1 Hoods, the required grease duct leakage test and light test shall be performed by a special
inspection and testing agency in accordance with I.M.C. Chapter 5.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1800 MECHANICAL FINAL
0701 ROUGH -IN MECHANICAL
CITY OF TUKW
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Mechanical Permit No. MIS'
Project No.
Date Application Accepted:
Date Application Expires:
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
SITE LOCATION
King Co Assessor's Tax No.:
Site Address: g qD 4 S /6" J /Gi br//1/1 Suite Number: / Floor: /
Tenant Name: fI 1' "1'1 495-'5. New Tenant: ❑ Yes X.. No
PROPERTY OWNER
Name: /e/ig Dort'
Name: <417
�,3.5-
Fax:
Phone:ig,, S/, - .21'65
Address:g9 9
...5 JH
/
City:r24�/0
State:
Zip:9if��
CONTACT PERSON — person receiving all project
communication
Name: /e/ig Dort'
Address: j 3/ 5 ,2(5-g 6 -7 --
City:
City:l.O41,hg Dil State:W 49 ZipgZfP9
6g1f1270
Fax:
Phone:ig,, S/, - .21'65
Email: 7-717Y/e774°47).774
� Y/er L°G7)v
MECHANICAL CONTRACTOR INFORMATION
Company Name: /4,ti*-- > //, s,/. ,,,14„.4,2e3 X11 /ye*
f>
Address: 3 j�, .�.245:0,
.24 5 %
City:„. 45'40'7State:k/Z", Zip:gf0V�
P ne j ez3i- ,,,6't,
� 2/ Fax.
Reg No.A2�/hi)(73� 7y Exp Date: ,,7/6. /2o/g
Tukwila Business License No.:ekt-__ 06...
%y
Valuation of project (contractor's bid price): $ VP/2i
Describe the scope of work in detail: ,..1.-7751// ,92 71' el/Y/7
�JnG7,/tis� i P�r�� sy,Ir/911 /22:vt2v OJT
Use: Residential: New ❑ Replacement ❑
Commercial: New ❑ Replacement ❑
Fuel Type: Electric
Gas ❑
Other:
H:\Applications\Forms-Applications On Linc\2016 Applications\Mechanical Permit Application Revised 1-4-I6.docx
Revised: January 2016
bh
Page 1 of 2
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
Residential, Nighttime
Furnace >100k btu
Industrial
Floor furnace
55 dB(A)
Suspended/wall/floor
;
mounted heater
`6�
Appliance vent
47 dB(A)
Repair or addition to
heat/refrig/cooling
system
65 dB(A)
Air handling unit
60 dB(A)
<10,000 cfm
65 dB(A)
Unit Type
Qty
Air handling unit
Residential, Nighttime
>10,000 cfm
Industrial
Evaporator cooler
55 dB(A)
Ventilation fan
connected to single duct
57 dB(A)
Ventilation system
Commercial
Hood and duct
47 dB(A)
Incinerator — domestic
65 dB(A)
Incinerator —
comm/industrial
60 dB(A)
Unit Type
Qty
Fire damper
Residential, Nighttime
Diffuser
Industrial
Thermostat
55 dB(A)
Wood/gas stove
57 dB(A)
Emergency generator
Commercial
Other mechanical
equipment
47 dB(A)
60 dB(A)
65 dB(A)
Boiler/Compressor
Qty
0-3 hp/100,000 btu
3-15 hp/500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+ hp/1,750,000 btu
Noise:
Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is
created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed.
For more details, see TMC 8.22
District of Sound
Producing Source
District of Receiving Property
Residential, Daytime*
Residential, Nighttime
Commercial
Industrial
Residential
55 dB(A)
45 dB(A)
57 dB(A)
60 dB(A)
Commercial
57 dB(A)
47 dB(A)
60 dB(A)
65 dB(A)
Industrial
60 dB(A)
50 dB(A)
65 dB(A)
70 dB(A)
*Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays.
A few sounds are exempt from the noise code, including:
• Warning devices;
• Construction and property maintenance during the daytime hours (7am-10pm);
• Testing of backup generators during the day.
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWN OR AUTHORIZED AGENT:
Signature: / '/l �!�f"�^ Date: / 3 '/
Print Name: liqK a/46%'7
Mailing Address:/3) di 42159 G7
H:\Applications\Forms-Applications On Linc\2016 Applications \Mechanical Permit Application Revised 1-4-16.docx
Revised: January 2016
hh
Day Telephone:
City
,07
-6,3/
State Zip
Page 2 of 2
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
PermitTRAK
1 ACCOUNT QUANTITY
PAID
$256.39
M18-0001 Address: 4904 S 164TH ST
Apn: 5379800390
$256.39
MECHANICAL
$244.18
PERMIT FEE
R000.322.100.00.00
0.00
$211.03
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$33.15
TECHNOLOGY FEE
$12.21
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R13138
R000.322.900.04.00 0.00
$12.21
$256.39
Date Paid: Wednesday, January 03, 2018
Paid By: PATRIOT HEATING AND A/C INC
Pay Method: CHECK 3027
Printed: Wednesday, January 03, 2018 10:14 AM 1 of 1
CRWYSTEMS
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project:
i c$$ RC -IDE, JCE
Type of Inspection:
/145:C / C4 -L .
2 NV -
Address: .
Wog 5, /6/77/ s -, r,
Date Called:
Special Instructions:
/Yt'N/ SPe/T
Date Wanted:
6 —Jet0 —/e
a.m)
p.m.
Requester:
RIcK
Phone No:
_
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
oK- 0611.-/N n'd c 4fW/U°r-Z
OK — - rtAliCthAryul/ -(
Inspector:
-13"
Date: _/5
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
PATRIOT HEATING & A/C INC
1-lorne Espanol Contact:
Safety & Health Claims & Insurance
0Washington State Department of
Labor & industries
0
Search L&I
Page 1 of 3
A -Z Index Help My I &I
Workplace Rights Trades & Licensing
PATRIOT HEATING & A/C INC
Owner or tradesperson
Principals
OWEN, RICK JAMES, PRESIDENT
Doing business as
PATRIOT HEATING & A/C INC
WA UBI No.
602 686 888
18318 SE 259TH CT
COVINGTON, WA 98042-5052
253-631-0601
KING County
Business type
Corporation
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
...._......_..._ ...............................
Meets current requirements.
License specialties
HeatingNent/Air-Conditioning and Refrig
(HVAC/R)
License no.
PATRIHA936CN
Effective — expiration
02/15/2007— 02/15/2019
Bond
WESTERN SURETY CO
Bond account no.
70240444
$6,000.00
Received by L&I Effective date
02/15/2007 02/01/2007
Expiration date
Until Canceled
Insurance
........ ...
Truck Ins Exchange
Policy no.
035140503
$1,000,000.00
Received by L&I Effective date
02/13/2017 02/09/2017
Expiration date
02/09/2018
Insurance history
Savings
No savings accounts during the previous 6 year period.
Lawsuits against the bond or savings
No lawsuits against the bond or savings accounts during the previous 6 year period.
L&I Tax debts
No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts
may be recorded by other agencies.
License Violations
Help us improve
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602686888&LIC=PATRIHA936CN&SAW= 1/3/2018
PATRIOT HEATING & A/C INC
Infraction no.
EJORP06560
Issue date
07/29/2015
Violation city
COVINGTON
Type of violation
ELECTRICAL CITATION
Description
Failing to get an inspection or obtain an
electrical/telecommunications work permit or
post a provisional electrical work permit prior
to beginning the electrical/telecommunication
installation or alteration as referenced in WAC
296-46B-901.
Infraction no.
EJORP06559
Issue date
07/29/2015
Violation city
COVINGTON
Type of violation
ELECTRICAL CITATION
Description
Offering to perform, submitting a bid for,
advertising, installing or maintaining cables,
conductors or equipment that convey or
utilize electrical current without having a valid
electrical contractor license.
Infraction no.
EJORP06561
Issue date
07/29/2015
Violation city
COVINGTON
Type of violation
ELECTRICAL CITATION
Description
Employing an individual for the purposes of
chapter 19.28 RCW who does not possess a
valid certificate of competency or training
certificate to do electrical work.
Satisfied
RCW/WAC
19.28.101 RCW
Violation amount
$250.00
Satisfied
.............._..
RCW/WAC
19.28.041 RCW
Violation amount
$500.00
Satisfied
RCW/WAC
19.28.271 RCW
Violation amount
$250.00
Workers' comp
Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums.
L&I Account ID
182,442-00
.................................
Doing business as
PATRIOT HEATING AND A/C INC
Estimated workers reported
Quarter 3 of Year 2017 "1 to 3 Workers"
L&I account contact
T2 / DALE RIUTTA (360)902-4834 - Email: RIUD235@Ini.wa.gov
Account is current.
Public Works Strikes and Debarments
Verify the contractor is eligible to perform work on public works projects.
Contractor Strikes
This contractor received a valid strike(s) for violation or infraction for the following L&I Vaw(s). Learn more about
contractor strikes.
RCW Violation
Effective Date
Page 2 of 3
Help us improve
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602686888&LIC=PATRIHA936CN&SAW= 1/3/2018