Loading...
HomeMy WebLinkAboutPermit M18-0004 - MANGUBAT - TITUS DESV BOXES, SENSORS, DUCTWORKMANGUBAT 16400 SOUTHCENTER PKWY SUITE 309 M18-0004 Parcel No: Address: Q City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 2623049021 Permit Number: M18-0004 16400 SOUTHCENTER PKWY Unit309 Project Name: MANGUBAT Issue Date: 1/17/2018 Permit Expires On: 7/16/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: RADOVICH PROPERTIES LLC 2835 82ND AVE SE STE S 1, MERCER ISLAND, WA, 98040 JOHN MERRILL 6426 18TH ST E , FIFE, WA, 98424 MECHANICAL & CONTROL SRVCS INC (GENERAL) 6426 18TH ST E , FIFE, WA, 98424 MECHACS962BT Phone: (253) 831-4446 Phone: (253) 926-9777 Expiration Date: 2/26/2018 DESCRIPTION OF WORK: INSTALL (2) TITUS DESV BOXES. RELOCATE SENSORS, MODIFY DUCTWORK TO ACCOMODATE NEW FL;OOR LAYOUT Valuation of Work: $6,500.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $299.50 Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Date: (7d(5 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: J0,4, s Date: p7/4-- This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 2: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 3: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 4: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 5: ***MECHANICAL PERMIT CONDITIONS*** 6: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 7: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. fi l — 000 Project No. Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 16400 SOUTHCENTER PARKWAY King Co Assessor's Tax No.: 2623049021 Suite Number: 3°9 Floor: 3 Tenant Name: MANGUBAT PROPERTY OWNER Name: JOHN MERRILL Name: RADOVICH PROPERTIES LLC City: FIFE State: WA Address: Zip: 98424 Phone: (253) 831-4446 Fax: (253) City: State: Zip: CONTACT PERSON — person receiving all project communication Name: JOHN MERRILL Address: 6426 18th ST E Address: 6426 18TH ST E City: FIFE State: WA City: FIFE State: WA Zip: 98424 Phone: (253) 831-4446 Fax: (253) 926-9222 Email: JOHNM@GROUPMCS.COM New Tenant: m Yes ❑ ..No MECHANICAL CONTRACTOR INFORMATION Company Name: Mechanical & Control Services Address: 6426 18th ST E City: FIFE State: WA Zip: 98424 Phone:(253) 926-9777 Fax: (253) 926-9222 Contr Reg No.: MECHACS962BT Exp Date: 02/26/2018 Tukwila Business License No.: 0997334 Valuation of project (contractor's bid price): $ 6,500 Describe the scope of work in detail: INSTALL (2) TITUS DESV BOXES. RELOCATE SENSORS. MODIFY DUCTWORK TO ACCOMODATE NEW FLOOR LAYOUT. Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement ❑ Fuel Type: Electric ❑ Gas ❑ Other: H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised I-4-16. docx Revised. January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 2 Air handling unit 65 dB(A) <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 2 Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) As. Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 2 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (lam -1 Opm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER ,/ R S RIZED AGEN Signature: Print Name: JOHN MERRILL Mailing Address: 6426 18TH ST E H:Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16. docx Revised. January 2016 bh Date: 01/02/2018 Day Telephone: (253) 8314446 FIFE WA 98424 City State Zip Page 2 of 2 DESCRIPTIONS PermitTRAK Cash Register Receipt City of Tukwila ACCOUNT QUANTITY PAID M18-0004 Address: 16400 SOUTHCENTER PKWY 310 Apn: 2623049( 21 99. Credit Card Fee $8.72 Credit Card Fee R000.369.908.00.00 0.00 $8.72 MECHANICAL $279.60 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $190.53 PLAN CHECK FEE R000.322.102.00.00 0.00 $55.92 TECHNOLOGY FEE $11.18 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R13188 R000.322.900.04.00 0.00 $11.18 $299.50 Date Paid: Friday, January 05, 2018 Paid By: JOHN PARKS Pay Method: CREDIT CARD 215020 Printed: Friday, January 05, 2018 10:02 AM 1 of 1 SYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: /i�`Fi1/GUBAr T Type of Inspection: ,,2W6t/-,N /y N !CAL Address: /o .5507-nerovizn Rod/ Date Called: Special Instructions:���.T 3� / Date Wanted: 1-31-18 al .. . Requester: sytwN Phone No: 20(e--53-1730 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 0/.4 — Rover -f -) N vvvrC(41W Cf4-'- t� - P/C/4- L ivver/ 404 (71 - Inspector: Date: !3`48 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter BLvd., Suite 100. Call to schedule reinspection. �litus Submittal DESV-1.0 08-01-2017 DESV Single Duct Terminal Unit Direct Digital Control, Pressure Independen W Control Enclosure (Optional on Cooling -Only units) M G EVIEVVED F CODE COMPLIA APPROVED JAN 1 0 2018 6 1/2" Right hand unit shown. All dimensions are in City of Tukwila 18" ► .-DINO DIV;;;;C) Slip & Drive Cleat Connection Inlet Size CFM Range D F G H L M W 4 0-225 3'/8 2 1/8 7 3/8 8 15 1/2 5 3/8 12 5 0-350 4'/8 2 1/8 7 3/8 8 151/2 5 3/8 12 6 0-500 5'/8 2 1/8 7 3/8 8 151/2 3 3/8 12 7 0-650 6'/8 1 1/8 7 3/8 10 151/2 3 3/8 12 8 0-900 7 7/8 1 1/8 7 3/8 10 151/2 3 3/8 12 9 0-1050 8'/8 - 5 3/8 121/2 151/2 3 3/8 14 10 0-1400 9'/8 - 5 3/8 121/2 15'/2 3 3/8 14 12 0-2000 11 7/8 - 5 3/8 15 151/2 3 3/8 16 14 0-3000 13'/8 - 3 3/8 171/2 151/2 3 3/8 20 16 0-4000 15'/8 - 3 3/8 18 151/2 3 3/8 24 24 x 16 0-8000 23'/8 x 15'/8 1 1/8 5 3/8 18 15 3 3/8 38 Accessories (Optional) Check 21 if provided. ❑ 24 V Control Transformer ❑ Dust Tight Enclosure Seal ❑ Fibre Free Liner ❑ 1/2" EcoShield Liner ❑ '/2" Fibre Free Liner General Description RECEIVED CITY OF TUKWILA JAN 0 5 2018 PERMIT CENTER 1" Fiberglass Liner 1" EcoShield Liner 1" Fibre Free Liner Low Leakage Seal/Test/Certify SteriLoc Liner ❑ UltraLoc Liner ❑ '/2" EcoShield Liner (Foil Face) ❑ 1" EcoShield Liner (Foil Face) ❑ Disconnect Switch ❑ Hanger Brackets • Heavy gauge steel housing. Mechanically sealed and gasketed, leak resistant construction. Less than 2% of nominal cfm at 1.5" sp wg. • Dual density intemal insulation, treated to resist air erosion. Meets requirements of NFPA 90A and UL 181. • Rectangular discharge opening is designed for slip and drive cleat duct connection. • Multipoint center averaging inlet velocity sensor. • Digital control packages can be factory mounted by Titus. • Choice of right hand or left hand control location. ❑ Removable Air Flow Sensor ❑ Bottom Access Door ❑ OSP & IBC Certification ❑ Red List Compliant "Google" Gasketing MIS- 000'i Model DESV without coils can be installed horizontally, vertically, or at any angle. Operation is not affected by position. For units with coils, consult technical support. • Gauge tees for cfm measurement. • OSHPD Seismic Certification: OSP-0352- 10 Only Titus Alpha digital controls package approved for seismic installation. This submittal is meant to demonstrate general dimensions of this product. The drawings are not meant to detail every aspect of the product. Drawings are not to scale. Titus reserves the right to make changes without written notice. All rights reserved. No part of this work may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or by any information storage retrieval system without permission in writing from Air Distribution Technologies, Inc. DESV-2.0 08-01-2017 Accessories (Optional) ❑ Hot Water Coil Section • Aluminum ripple fins, 10 per inch • Coil pipe connections are male, sweat, type "L" copper. Connection sizes are %" OD for 1 row coil unit sizes 04-08. All other coils have 1/8" OD. • Coil is installed at discharge of unit. • On units with attenuators, coil are installed at the discharge of attenuator. ❑ 1 Row ❑ 2 Row ❑ 3 Row ❑ 4 Row 0 0 L_� W ❑ Electric Coil Section 0 Optional Standard Features • Single side access to low voltage, high voltage, and electric heater controls. • Automatic reset thermal cutouts, one per element • Manual reset secondary protection. • Positive pressure flow switch • Magnetic contactor for each step. • Slip and drive cleat discharge duct connection. SCR Controlled Electric Heater Options ❑ Fuse Block ❑ Disconnect switch, door interlock type ❑ Dust tight construction 0 Mercury contactors 392 •E 368 0 Optional Lynergy Controlled Electric Heater Supply Voltage ❑ 120V, 1 ph, 60Hz ❑ 208V, 1 ph, 60Hz ❑ 240V, 1 ph, 60Hz -6 1/4 W ❑ 277V, 1 ph, 60Hz ❑ 208V, 3 ph, 60Hz ❑ 480V, 3 ph, 60Hz (4 wire wye standard) 12 ri RH 0 Integral Sound Attenuator li• 18 392 1 -62 W 12 1/4 -I Inlet Size H W Water Coil L (1-2 Row) L (3-4 Row) 4 8 12 5 7'/4 5 8 12 5 j '/4 thr\ * 1/4 7' ' #0 2 5 • 7'/4 8 1b t 2 5 417t/ /4 9 12'/2 14 5 7'/4 10 12'/2 14 5 7'/4 12 15 16 5 7'/4 14 17'/2 20 7'/2 9 3/4 16 18 24 7'/2 9 3/4 24 x 16 18 38 5 7'/4 The total length of the DESV unit is the summation of the unit length (with or without attenuator) and the length of the optional water coil. This submittal is meant to demonstrate general dimensions of this product. The drawings are not meant to detail every aspect of the product. Drawings are not to scale. Titus reserves the right to make changes without written notice. All rights reserved. No part of this work may be reproduced or transmitted in any form or by any means, electronic or mechanical, induding photocopying and recording, or by any information storage retrieval system without permission in writing from Air Distribution Technologies, Inc. GENERAL HVAC NOTES 1. THE FOLLOWING NOTES APPLY TO ALL MECHANICAL DRAWINGS. ADDITIONAL MECHANICAL NOTES MAY BE INDICATED ON EACH MECHANICAL DRAWING. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS WHEN AVAILABLE. 2. INSTALLATION SHALL COMPLY WITH ALL GOVERNING CODES AND REGULATIONS (LOCAL AND STATE). NOTHING ON THE DRAWINGS OR SPECIFICATIONS SHALL BE C^ TRUED AS ALLOWING DEVIATION FROM THIS REQUIREMENT. IF A CONFLICT SOW LD OCCUR BETWEEN DRAWINGS AND REGULATIONS, THE REGULATIONS SHALL TAKE PRECEDENT AND CONTRACTOR SHALL NOTIFY ENGINEER IN WRONG OF SUCH CONFLICT PRIOR TO PROCEEDING WITH INSTALLATION. 3. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR GENERAL COOSTRUCTION INCLUDING LOUVERS, CONCRETE EQUIPMENT PADS, FLASHING DETAILS, ETC. 4. REFER TO ARCHITECTURAL DRAWING FOR ROOM ELEVATIONS. LOCATE MECHANICAL DEVICES SUCH AS TEMPERATURE SENSORS, HUMIDISTAT, PANELS, ETC. SO THAT THEY DO NOT CONFLICT WITH GENERAL CONSTRUCTION (WAINSCOT, DOOR HARDWARE, ETC.) NOR WITH THE ELECTRICAL SYSTEM (LIGHT SWITCHES, SPEAKERS, OUTLETS, ETC.) MOUNT THERMOSTATS 48" AFF UNO. 5. MECHANICAL DRAWINGS SHOW APPROXIMATE LOCATIONS FOR GRILLES AND DIFFUSERS. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF GRILLES, REGISTERS, DIFFUSERS AND OTHER CEILING OR SURFACE MOUNTED DEVICES. INSTALL EQUIPMENT IN CONFORMANCE WITH ARCHITECTURAL FEATURES IN THE CENTER OF CEILING TILES, IN THE CENTER OF ROOMS, OR WHERE INDICATED ON ARCHITECTURAL DRAWINGS. WHERE EQUIPMENT IS NOT INDICATED ON ARCHITECTURAL DRAWINGS OBTAIN DIRECTION FROM ARCHITECT PRIOR TO INSTALLATION. 6. SEE ARCH. DRAWINGS FOR EXACT SIZE AND LOCATION OF LOUVERS. COORDINATE EXACT SIZE OF ATTACHED DUCTWORK/PLENUM AND/OR MOTORIZED DAMPERS WITH ARCH. DRAWINGS. 7. GENERALLY DUCTWORK PLANNED TO BE TIGHT TO STRUCTURE WITH PIPING BELOW DUCTWORK AND BETWEEN LIGHT FIXTURES. ADJUST AS NECESSARY. 8. COORDINATE LOCATIONS OF MECHANICAL EQUIPMENT AND DUCTWORK TO PROVIDE CLEARANCES OVER LIGHTING FIXTURES FOR REMOVAL AND SERVICE ACCESS DUE TO EQUIPMENT MAINTENANCE. 9. ARRANGE HVAC EQUIPMENT SO THAT ACCESS CLEARANCES INDICATED BY DRAWINGS, REQUIRED BY CODES AND RECOMMENDED BY MANUFACTURER ARE PROVIDED. PROVIDE 42" CLEAR AT DISCONNECT SWITCH ON TERMINAL UNITS WITH ELECTRIC HEATING COIL. 10. GENERAL CONTRACTOR TO PROVIDE ACCESS TO FIRE AND/OR COMBINATION FIRE/SMOKE DAMPERS THROUGH ACCESS DOORS IN HARD CEILINGS AND WALLS. WHERE ACCESS DOORS PENETRATE FIRE RATED SYSTEMS THEY SHALL BE RATED IN ACCORDANCE WITH IBC REQUIREMENTS. 11. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL ELECTRICAL CHARACTERISTICS OF MECHANICAL EQUIPMENT (VOLTAGES ETC.) 12. DUCTWORK AND PIPING INSTALLED ADJACENT TO ELECTRICAL CABLE TRAYS SHALL ALLOW MINIMUM ACCESS OF 6" IF RUNNING PARALLEL AND ABOVE CABLE TRAYS, ALLOW 18" TO THE SIDE OF CABLE TRAYS. 13. ELECTRICAL CHARACTERISTICS OF LISTED EQUIPMENT SHALL BE VERIFIED BY CONTRACTOR DURING SUBMITTAL PROCESS. ANY ELECTRICAL CHARACTERISTICS THAT DEVIATE FROM THOSE LISTED SHALL BE IDENTIFIED BY THE CONTRACTOR, SUBMITTED TO THE ENGINEER FOR APPROVAL AND COORDINATED WITH THE ELECTRICAL DIVISION PRIOR TO INSTALLATION OF EQUIPMENT AS REQUIRED TO PROPERLY SERVE EQUIPMENT. 14. DRAWINGS ARE SCHEMATIC IN SOME AREAS AND MAY NOT SHOW OFFSETS WHICH MAY BE REQUIRED. PROVIDE OFFSETS AS REQUIRED AT NO ADDITIONAL COST. 15. REFER TO PIPING DIAGRAMS AND DETAILS FOR REQUIRED FITTINGS, VALVES, ETC. FLOOR PLANS AND SECTIONS INDICATE EQUIPMENT LOCATIONS AND GENERAL PIPE ROUTING ONLY. 16. DUCTS AND PIPES INDICATED WITHOUT DIMENSIONS SHALL BE SIZED PER PRECEDING UPSTREAM DUCT AND PIPE SECTIONS. 17. DUCTWORK SIZES SHOWN ARE CLEAR INSIDE DIMENSION. 18. PROVIDE FABRICATED STEEL MEMBER SUPPORTS AS REQUIRED BY MANUFACTURER'S INSTALLATION INSTRUCTIONS, AS INDICATED ON DRAWINGS OR IN SPECIFICATIONS FOR INSTALLATION OF EQUIPMENT. REQUIRED STRUCTURAL MEMBERS, BOLTS AND WELDS SHALL BE IN ACCORDANCE WITH AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) MANUAL. 19. IF REQUIRED FOR INSTALLATION OF PIPES, DUCTS AND EQUIPMENT, PROVIDE ADDITIONAL STRUCTURAL MEMBERS BETWEEN COLUMNS, JOISTS AND STRUCTURAL FRAME TO MEET SUPPORT REACTIONS (FORCES, MOMENTS, DEFLECTIONS). STRUCTURAL MEMBERS SHALL BE DESIGNED BY A REGISTERED PROFESSIONAL ENGINEER. 20. DO NOT CORE DRILL OR DRILL THROUGH BEAMS, COLUMNS AND SHEAR WALLS, UNLESS INDICATED ON STRUCTURAL DRAWINGS OR AS APPROVED BY STRUCTURAL ENGINEER. 21. PROVIDE DUCT LINING FOR THE FOLLOWING DUCTWORK: A. ALL THE AIR TRANSFER DUCTS AND CEILING RELIEF GRILLES. B. OTHER LOCATIONS WHERE NOTED ON DRAWINGS OR SPECIFIED. 22. PROVIDE VOLUME DAMPERS FOR EACH SUPPLY BRANCH, RETURN BRANCH (DUCTED ONLY) AND EXHAUST BRANCH WHERE THREE OR MORE OPENINGS ARE ASSOCIATED WITH THE BRANCH AND ELSEWHERE AS NOTED ON DRAWINGS OR IN SPECIFICATIONS. 23. PROVIDE CONICAL SPIN -IN FITTINGS FOR ALL 90 DEGREE ROUND DUCT BRCHES FROM RECTANGULAR SUPPLY DUCTWORK. DO NOT USE STRAIGHT TEE -FITTINGS. 24. DUCTWORK STATIC PRESSURE AND SEAL CLASS, BASED UPON SMACNA. 25. REFER TO SEATTLE NREC COMPLIANCE REQUIREMENTS ON DRAWINGS SCHEDULE SHEETS FOR ADDITIONAL MECHANICAL PROVISIONS. 26. SEA'1 AND LEAK TEST DUCTWORK PER -2015 IMC & 2015 WSEC. 27. BALANCE HVAC SYSTEM PER SEC. 28. COMMISSION HVAC SYSTEM PER SEC. 29. PROVIDE COMPLETION/RECORD DRAWINGS PER SEC. 30. INSULATE DUCTWORK PER SEC. 31. PROVIDE MEANS OF ACCESSING/ADJUSTING BALANCING DAMPERS AT ALL LOCATIONS WHERE MEANS OF ACCESS HAS NOT BEEN SHOWN ON ARCHITECTURAL DRAWINGS. PROVIDE UNITED ENERTECH I -SERIES REMOTE POWER/BALANCE SYSTEM OR APPROVED EQUAL. COORDINATE LOCATION OF REMOTE JACK WITH ARCHITECT AND RECORD ON AS -BUILT DRAWINGS. ADDRESS:16400 SOUTHCENTER PARKWAY, TUKWILA, WA 98188 PARCEL: 2623049021 TENANT: MANGUBAT SCOPE: INSTALL (2) TITUS DESV BOXES. MODIFY EXISTING DUCTWORK WHERE NECESSARY TO ACCOMMODATE NEW FLOOR LAYOUT. REVISIONS No chances shall h^ made to the scope of work with' prior approval of E!.iildinq Division. NOTE: levision3 i q i rc :i n..^r.v plan subm!tta- and may i-' '::d3 ad ';t!onal plan rev cw fees SEPARATE TE PERA IT REO{ `IRI D FOR: Mechanical lectncal Iumbing L`1 Gas Piping City of Tukwila Vii!'- `^ f':VISION 0) 0 -.1 1 m z m 70 STRANDER BOULEVARD ��IIIIIIIIIIIIIIIIIIIIII� CIIIIIIIIIIIIOIIIIIIIIq 1111111111211�U 11111111 1 2' Ciiilll~1321III~I� IIIIIIIIIIIIIIIIIIIIII� =1111 del lor SITE PLAN 1 ii_1, 128 VAV BOX SCHEDULE TAG MANUFACTURER MODEL MAX CFM MIN CFM DESV-1, 2 TITUS DESV 265-900 145-590 FILE COPY Permit No. MI ' W°1-1- Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By: �. Date: 1//-7/i City of Tukwila BUILDING DIVISION MANGUBAT TI 16400 SOUTHCENTER PARKWAY TUKWILA, WA 98188 CCDE COMPUANC` APPROVED SAN 1.0 201B P -J City of Tukwila RECEIVED BUI `DING DIVISION CITY OF TUKWILA JAN 052018 PERMIT CENTER MI8OoOti SCALE DATE N/A 1/2/18 COVER PAGE M-1 .0 MANGUBAT PARTIAL FLOOR PLAN =1' MECHANICAL d CONTROL SERVICES. INC MANGUBAT TI 16400 SOUTHCENTER PARKWAY TUKWILA, WA 98188 SCOPE: MODIFY DUCTWORK & DIFFUSERS TO ACCOMMODATE NEW FLOOR LAYOUT.INSTALL (2) TITUS DESV BOXES. REVIEWED FCR CODE COMPLIANCE APPROVED JAN 1 [i 2013 City of Tukwila I BUILDING DIViS ON RECEIVED CITY OF TUKWILA JAN 0 5 2018 PERMIT CENTER SCALE DATE 1/8" = 1' 1/2/18 MECH PLAN M - 1 .1 9ERMITCOORDCOPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0004 DATE: 01/05/18 PROJECT NAME: MANGUBAT SITE ADDRESS: 16400 SOUTHCENTER PKWY - SUITE 309 X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: \ \ill f?[ilding Division Public Works ❑ Fire re Pre e on Structural Planning Division ❑ Permit Coordinator 1 PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 01/09/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE 02/06/18 Approved Corrections Required ❑ Approved with Conditions ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 MECHANICAL & CONTROL SRVe3 INC liinne ESi i iol Contact Safety & Health Claims & Insurance Ci) Washington State Department of Labor & Industries Search L&I Page 1 of 2 SEARct A -Z Index Help My 'MI Workplace Rights Trades & Licensing MECHANICAL & CONTROL SRVCS INC Owner or tradesperson Hull, Travis Edward Principals Hull, Travis Edward, PRESIDENT Hunt, Ted Lamond, VICE PRESIDENT HULL, ANGELA DAWN, SECRETARY GROVER, HAROLD, VICE PRESIDENT (End: 02/26/2010) DICKSON, PAUL, TREASURER (End: 02/26/2010) WA UBI No. 602 338 440 6426 18th St E FIFE, WA 98424 253-926-9777 PIERCE County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. MECHACS962BT Effective — expiration 01/30/2004— 02/26/2018 Bond American Contractors Indem CO Bond account no. 100239439 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 02/10/2014 02/06/2014 Expiration date Until Canceled Bond history Insurance Continental Western Ins Co $1,000,000.00 Policy no. 6023856626 Received by L&I Effective date 01/20/2017 01/23/2016 Expiration date 01/23/2018 Insurance history Savings Help us improve https://seeure.lni.wa.gov/verify/Detail.aspx?UBI=602338440&LIC=MECHACS962BT&SAW= 1/17/2018