Permit M18-0008 - DIECUT STICKERS - WALL MOUNT A/C AND HUMIDIFIER IN PRINTER ROOM
DIECUT STICKERS 345 ANDOVER PARK E MI 8-0008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov Parcel No: 0223400040 Address: MECHANICAL PERMIT Permit Number: M18-0008 345 ANDOVER PARK E BLDG 1 Issue Date: 3/2/2018 Permit Expires On: 8/29/2018 Project Name: DIECUT STICKERS Owner: Name: Address: AVERE INVESTMENTS LLC 5436 NE 10TH ST, RENTON, WA, 98059 Contact Person: Name: ALLEN PATTON Address: 3602 SOUTH PINE ST, TACOMA, WA, 98409 Contractor: Name: AIR SYSTEMS ENGINEERING INC (CONST) Address: 3602 S PINE ST, TACOMA, WA, 98409 License No: AIRSYE*229KN Expiration Date: 2/1/2020 Phone: (253) 572-9484 Phone: (206) 628-9484 Lender: Name: Address: /11 DESCRIPTION OF WORK: FURNISH AND INSTALL (1) 3 TON NEW FUJITSU WALL MOUNT AIR CONDITIONER FOR PRINTER ROOM. FURNISH AND INSTALL (1) NEW WALL MOUNT HONEYWELL BRAND HUMIDIFIER FOR MAINTAINING ADJUSTABLE HUMIDITY WITHIN REASON 40- 50% RH. FURNISH AND INSTALL (1) LOSSNAY BRAND 300 CFM ERV SYSTEM FOR EXHAUSTING ODOR OF NEW PRINTER. Valuation of Work: $11,985.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $357.41 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signature: !i'i15 Date: I hearby certify that I have read and examined this permit and now the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and ktee`o the conditions attached to this permit. Signature: Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the 'Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. 1 — C eaY Project No. Date Application Accepted: Date Application Expires: °l 9//6, // O7//(/// (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 1729 Site Address: 345 Andover Park E Suite Number: Floor: Tenant Name: Diecut Stickers.com PROPERTY OWNER Name: Allen Patton Name: Medford Technologies City: Tacoma State: WA Zip: 98409 Address: 345 Andover Park E #2 Email: AllenP@asei.ws Cin': Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Allen Patton Address: 3602 South Pine St City: Tacoma State: WA Zip: 98409 Phone: (253) 572-9484 Fax: (253) 383-6337 Email: AllenP@asei.ws New Tenant: ❑ Yes ® .. No MECHANICAL CONTRACTOR INFORMATION Company Name: Air Systems Engineering Inc Address: 3602 South Pine St City: Tacoma State: WA Zip: 98409 Phone: (253) 572-2948 Fax: (253) 383-6337 Contr Reg No.: AIRSYE*229KN Exp Date: 02/01/2018 Tukwila Business License No.: BUS -0997632 Valuation of project (contractor's bid price): $ 11,985 Describe the scope of work in detail: -Furnish and install (1) 3 ton new Fujitsu wall mount air conditioner for printer room. •Furnish and install (1) new wall mount Honeywell brand humidifier for maintaining adjustable humidity within reason 40- 50%rh. .Furnish and install (1) Lossnay brand 300 cfm ERV system for exhausting odor of new printer. Use: Residential: New ❑ Commercial: New Fuel Type: Electric ❑ Replacement Replacement Gas ❑ Other: H:\ Appliwtions\ronns-Applications On Line'2016 Applications \Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 2 Suspended/wall/floor mounted heater 1 Appliance vent 1 Repair or addition to heat refrig-cooling system 47 dB(A) Air handling unit 65 dB(A) <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 2 Ventilation fan connected to single duct 57 dB(A) Ventilation system 1 Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 2 Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-1 OPM, Monday through Friday and 8AM-10PM, Saturday, Sunday aid State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (lam -I Opm); Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction - in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON. AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWORIZED AGENT: Signature: Date: i '(A\ (id Print Name: Will Santo Domingo Day Telephone: (253) 572-9484 Mailing Address: 3602 South Pine St H:\Applicuuons\Forms-Applications ()n Line 2016 Applications\Mechanical Permit Application Rcvised 1-4-16.docx Revised: January 2016 bit Tacoma WA 98409 City State Zip Page 2 of 2 PermitTRAK DESCRIPTIONS Cash Register Receipt City of Tukwila ACCOUNT QUANTITY PAID EL18-0058 Address: 345 ANDOVER PARK "E BLDG ELECTRICAL 422340004 165.03 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $165.03 TECHNOLOGY FEE $8.25 TECHNOLOGY FEE R000.322.900.04.00 0.00 $8.25 M18-0008 Address: 345 ANDOVER PARK E BLDG 1 n: 0223400040 57.4 MECHANICAL $343.66 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $241.78 PLAN CHECK FEE R000.322.102.00.00 0.00 $68.73 TECHNOLOGY FEE $13:75 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R13400 R000.322.900.04.00 0.00 $13.75 $530.69 Date Paid: Tuesday, January 16, 2018 Paid By: AIR SYSTEMS ENGINEERING INC Pay Method: CHECK 104435 Printed: Tuesday, January 16, 2018 12:43 PM 1 of 1 CRWSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Prot: D'fi G� -scArA Tye of Inspection: r r Iectt RT at FiktwL Address: 3y�- Aelwoor,fsrr ARx £ Date Called: Special Instructions:1 _ _ _ R[�. Date Wanted: a.m. p.m. Requester: Phone No: 253 LIDS F37 TAApproved per applicable codes. Corrections required prior to approval. COMMENTS: a f e d- recd 1_ vv O Nkeci1, Fl .— +pVVei Ins7oLQQ(tO;: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. FUJITSU Hairci*- Submittal Data:36RLXB Inverter Driven Ileat Pump 36,000 Will Wall Mount Job Name: Location: Printer & Equipment Room Engineer: Submitted to: Diecut Stickers.com Submitted by: Reference: n L7.; Date: Approval: Construction: Unit #: REVIEWED FOR CODE COMP' LANCE APPROVED FEB 01 2018 Drawing #: City of Tukwila BUILDING DIVISION •Wired or wireless remote • Apple catechin filter • Energy Star rated •Sleep timer •Auto louver: 4 -way •Auto mode •Auto changeover •Blue fin coating General Features •Standard Warranty: 5 years parts, 7 years compressor. Applies to systems purchased before June 1" 2015* -Extended Warranty: 10 years parts, 10 years compressor. Systems that have been installed on or after June 1" 2015 by licensed contractors and the online Product Registration has been submitted.** -Elite Contractor Extended Warranty: 12 years parts, 12 years compressor. Systems that have been installed on or after June 1" 2015 by contractors who have met requirements and have been approved for elite contractor status plus, the online Product Registration has been submitted. '•' Model Information Condenser AOU36RLXB Evaporator ASU36RLXB Electrical 208/230V AC l ph-60Hz Available Voltage Range ..... 208/230+/- 10% Minimum Circuit Ampacity ... 23.3 A Max Fuse Size 30A Max Starting Current 17 A Input Power Cooling 3.88 kW Heating 3.39 kW Running Current Cooling 17 A Heating 14.8 A Capacity Nominal Cooling °.. 33,000 Btu/h Min -Max Cooling 9,900 — 34,100 Btu/h Nominal Heating ... 34,000 Btu/h Min -Max Heatinl, RECEIVED. 10 00. — 35,000 Btu/h Compressor F CITY 0r TUKWI Rotary (inv xl) Motor Output 2,100 W Refrigerant R410a Charge 4lbs. 10.1oz Oil POE (RB68) Fan Motor PERMIT CENTER (Condenser) Type: DC Propeller x 1 (Condenser) Motor Output 100 W (Evaporator) Type: DC Cross flow fan x 1 (Evaporator) Motor Output 65 W Thermal Protection (On) 248 ± 27°F (120 ± 15°C) Evaporator (Off) .... 302 ± 27°F (150 ± 15°C) Condenser (On) 248 ± 27°F (120 ± 15°C) / (Off) 302 ± 27°F (150 ± 15°C) Heat Exchanger Dimensions (H x W x D) in. (mm) 31-7/16 x 35-7/16 x 1-7/16 (798x900x36.4) Fin Fitch 20 FPI Rows x Stages 2 x 38 Pipe Type (Material) °.... Copper Fin Type (Material) Aluminum (Blue Fin) JAN 1 6 2018 Nord Spec fiaanans are based an the ti.loveing conditions. Cooling( Ian o r temperature or g0°F 126.1'C) UB/67°F 1I9 44°C) WB. and outdoor temperature 01-95.F 135'CI DB175'F 123 9'O WB. Ideating: Indoor temperature or 70"F 121.1 I "'C) DB/59°F (15.1C) W13. and outdoor temperature nr47 F IR.33"(;) DB/43.F 1, 1 PC) WB. Pipe length: 245. lin. )O.Sml. Height dilramoe: O5. Om) (Outdoor unit Indoor unit) 1 oft Operation Temperature - Range Cooling I4°F (-10°C) - 115°F (-46°C) Heating 5°F (-15°C) - 75°F (-24°C) Efficiency SEER 15.5 EER (cooling) COP (heating) HSPF (heating) . 2.50 kW/kW / 8.5 Btu/hW 2.94 kW/kW / 10.0 Btu/hW 9.0 Btu/hW Enclosure (Condenser) Material Color Sound Pressure Level Condenser 55 dB(A) Evaporator .... 50 dB(A) Dimensions HxWxD Condenser in. (mm) Evaporator in. (mm) Connection Pipe Liquid Painted galvanized steel Beige (10 YR 7.5/1.0 NN) Gas 32-11/16x 35-7/16x 13 (830x900x330) 12-10/16x 39-5/16x 9 (320x998x228) 3/8" 5/8" Method (Liquid/Gas) Brazing Pre -charge 66 ft. (20m) Minimum Length 16 ft. (5m) Max Length (Pre -charge). 164 ft. (50m) / (65 ft. {20m}) 0.43oz / ft. over 66 ft. Max Height Difference 98 ft. (30m) Weight Condenser Evaporator Accessories UTY-RVNUM UTY-RNNUM UTY-RSN`UM Configuration Heating only or cooling only field setting configuration required. ear0 ar 134 lbs. (61 kg) 31 lbs. (14 kg) Wired remote control (backlit, displays room temp.) Wired remote control Wired remote control (simple) -Year Fujitsu General America, Inc. 353 Route 46 West Fairfield, NJ 07)8)4 Toll Free: 1-888-888-3424 Fax: (973) 836-0447 FUJITSU ktakydii Dimensions:36RLXB 39-5/16 (998) L3) 20-1/2 (520) 23-1/4 (590) 28-3/8 (721) 2-) 20-1/2 (520) Top view 3-1/16 (77) 1-1/4 (31) 13 (330) 1/2 (12) 0 0 E't "'Side ;view CO CI ((1!�l'If�117111�111� IFAhI 11■ ■l!(^�CD Bottom view ilk The Fujitsu logo is a registe demarl'o, Fu itsU Limited,. ,',t* The Halcyon logo and nam delluark of Fujit4 GeneraIAnteInc Copynghr 2014 Fujitsu General America, Inc. .t , t `• „.r. .4 , r y Fujitsu's products are subject To continuous improvements. Fujitsu reserves the right to modify product design, specifications and information in this brochure without notice and without incurring any obligations. 5-13/16 (147) 2 of 2 1/16 (170) [Unit: in. (mm)] 12-5/8 (320) Fujitsu General America, Inc. 353 Route 46 West Fairfield, NJ 07004 Toll Free: 1-888-888-3424 Fax: (973) 836-0447 yVWvr tiljitsu;2cneral.cont Dedicated Outdoor Air System (DOAS) Sizing Summary for Printers & Equipment Project Name: Untitled 01/08/2016 Prepared by: Air Systems Engineering, Inc. 09:38Ab Air System Information Air System Name Printers & Equipment Equipment Class TERM Air System Type VRF Sizing Calculation Information Number of zones 1 Floor Area 500.0 ft2 Location Seattle IAP, Washington Calculation Months Jan to Dec Zone CFM Sizing Sum of space airflow rates Sizing Data Calculated Space CFM Sizing Individual peak space Toads Cooling Coil Sizing Data Total coil load 0.1 Tons Load occurs at Aug 1500 Total coil load 1.0 MBH OA DB / WB 85.0 / 65.0 °F Sensible coil Toad 1.0 MBH Entering DB / WB 79.8 / 63.3 °F Coil CFM at Aug 1500 190 CFM Leaving DB / WB 75.0 / 61.6 °F Max coil CFM 190 CFM Bypass Factor 0.100 Sensible heat ratio 1.000 Water flow @ 10.0 °F rise N/A Heating Coil Sizing Data Max coil Toad 5.1 MBH Load occurs at Des Htg Coil CFM at Des Htg 190 CFM Ent. DB / Lvg DB 44.9 / 70.0 °F Max coil CFM 190 CFM Water flow @ 20.0 °F drop N/A Humidifier Sizing Data Max steam flow at Des Htg 4.92 Ib/hr Air mass flow 841.22 Ib/hr Airflow Rate 190 CFM Moisture gain .00585 Ib/Ib Ventilation Fan Sizing Data Actual max CFM 190 CFM Fan motor BHP 0.00 BHP Standard CFM 187 CFM Fan motor kW 0.00 kW Actual max CFM/ft2 0.38 CFM/ft2 Fan static 0.00 in wg Outdoor Ventilation Air Data Design airflow CFM 190 CFM CFM/person 14.62 CFM/person CFM/ft2 0.38 CFM/ft2 p Hourly Analysis Program v5.01 Page 1 of 2 Air System Design Load Summary for Printers & Equipment Project Name: Untitled Prepared by: Air Systems Engineering, Inc. 01/08/201( 09:38AIV Hourly Analysis Program v5.01 Page 2 of 2 DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1300 COOLING OA DB / WB 82.0 °F / 64.4 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 371 ft2 111 - 371 ft2 654 - Roof Transmission 500 ft2 784 - 500 ft2 523 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 500 ft2 0 - 500 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 625 W 1690 - 0 0 - Task Lighting 1500 W 4528 - 0 0 - Electric Equipment 7000 W 21668 - 0 0 - People 13 2358 2665 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 31138 2665 - 1178 0 Zone Conditioning - 32566 2665 - 1190 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Exhaust Fan Load 190 CFM 0 - 190 CFM 0 - Ventilation Load 190 CFM 794 -1122 190 CFM 4412 5193 Ventilation Fan Load 190 CFM 0 - 190 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 33360 1543 - 5602 5193 Cooling Coil - 617 0 - 0 0 Heating Coil - 0 - - 5077 - Terminal Unit Cooling - 32743 1544 - 0 0 Terminal Unit Heating - 0 - - 525 - Humidification Load - - 0 -- 5193 » Total Conditioning - 33360 1544 - 5602 5193 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v5.01 Page 2 of 2 +1Assnay Model: LGH-F300RX5-E1 MITSUBISHI /\ ELECTRIC Job Name: Diecut Stickers.com Printer & Equipment Room System Reference: ERV -1 Date: ENERGY RECOVERY VENTILATOR GENERAL FEATURES • Lossnay® cross-flow energy recovery core • Minimal cross contamination (<1% overall) between entering and leaving air streams • Stand-alone control • M -NET • Extemal input bypass damper control • Stand alone or interlocks with all Mitsubishi product SPECIFICATIONS Capacity 300 CFM / 8.5 m3/min Power Power Source. 208 - 230V, 1 -Phase, 60 Hz Power Consumption 0.067 - 0.300 kW Current 0 32 - 1.35 A Starting Current . 2 5 A Minimum CircuitAmpacity (MCA) 1 8A Maximum Overcurrent Protection (MOCP) 15 A Controllers PZ-60DR Lossnay® Controller: Controls 1-15 Lossnay® units, ON/OFF, Fan Speed, and Vent Mode Operation Mode • Heat Recovery • Bypass • Auto Air Volume (fan speed: extra low - low - high - extra high) @ 208V 91 - 203 - 260 - 300 CFM @ 230V 112 - 235 - 300 - 300 CFM Temperature recovery efficiency (fan speed: extra low - low - high - extra high) @ 208V 81- 71 - 67.5 - 65.5% @ 230V 79 - 69 - 65.5 - 65.5% Enthalphy recovery efficiency (fan speed: extra low - low - high - extra high) Heating @ 208V 79 - 68 - 65 - 63 % @ 230V 77 - 66 - 63 63 Cooling @208V 63 - 55 - 52 - 50% @230V 61 -53-50 50% Extemal static pressure (In. W.G.) (fan speed: extra low - low - high - extra high) @ 208V 0.06 - 0.28 - 0.46 - 0.60 @ 230V 0.08-0.33-0.54-0.78 External Finish Galvanized steel sheet Dimensions inches ... 12-3/8 H x 40 W x 34-15/16 D mm 315Hx1016Wx888D Net Weight 73 Ib / 33 kg Energy Transfer. Lossnay® core Heat Exchange System Air-to-air total heat (sensible heat + latent heat) exchange, no moving parts Heat Exchange Material Partition, spacing plate -cellulose fiber membrane Blower .... 9.625 in. dia. centrigugal fan Motor Totally enclosed capacitor permanent split -phase induction motor, 4 poles, 2 unit Filter Washable fiber (2) Entering Air Temperature Operation Range 14° F to 104° F (-10° C to 40° C), RH 80% or less Sound Pressure Level (fan speed: extra low - low - high - extra high) @ 208V 18-25.5-30.5-34 dB (A) @230V 18-27.5-33-37dB(A) Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc. Model: LGH-F300RX5-E1 - DIMENSIONS Position where duct direction change is possible *LGH -F470 and F600RX5-E1 types Bypass damper plate (4-9/16" X 13/16" (4-15 X 20) oval) Ceiling suspension fixture 0 (4-1/2 X 13/16" F (4-13 X 20) oval)' 1 M / •N11_ EA•i m (exhaust air outlet) OA (outside air intake) Core, air filter, High - Efficiency filter, fan, maintenance space «RA (retum air) c SA (supply air) Power supply cable opening Air supply fan Control box Maintenance cover Lossnay core High -Efficiency filter (sold separately) attachment position J A J w Mau Position where duct Air filters direction change is possible Accessory parts • Mounting screws x16 • Duct connecting flanges x4 (double flanges at SA and EA sides) • P -Series - Lossnay connection cable (gray: two wires) x1 Unit: Inch (mm) Model Dimensions Ceiling suspension fixture pitch Nominal diameter Duct connecting flange Duct pitch Weight B C D E F G H J K L M N LGH F300RX5 E1 3415/16 (888) 40 (1016) 12 3/8 (315) 34 1/2 (875) 41 7/8 (1063) 2 9/16 (65) 7 7/8 (200) 7 9/16 (192) 8 3/16 (208) 31/8 (79) 29 3/8 (745) 5 5/16 (135.5) 4 7/8 (124) 1 3/16 (30) 73 lbs (33 kg) LGH-F470RX5-E1 451/16 (1144) 39 1/2 (1004) 153/4 (399) 39 3/4 (1010) 4013/16 (1036) 15 5/16 (389) 9 7/8 (250) 91/2 (242) 10 3/16 (258) 31/8 (79) 27 3/16 (690) 6 3/16 (157) 61/2 (165) — 119 lbs (54 kg) LGH-F6011RX5 E1 451/16 (1144) 481/2 (1231) 15 3/4 (399) 39 3/4 (1010) 49 3/4 (1263) 15 5/16 (389) 9 7/8 (250) 9 1/2 (242) 10 3/16 (258) 31/8 (79) 361/8 (917) 6 3/16 (157) 61/2 (165) _ 132 lbs (60 kg) FORM# LGH-F300RX5-E1 - 201609 Specifications are subject to change without notice. mt MBIELEC�SH COOLING & HEATING 1340 Satellite Boulevard. Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com Intertek © 2016 Mitsubishi Electric US, Inc. Honeywell H M 750A1000 ADVANCED ELECTRODE STEAM HUMIDIFIER Job Name Engineer Mechanical Contractor Contractor's P.O. No. Representative Notes APPLICATION The HM750 is the most advanced residential steam humidifier available and provides steady and reliable humidification for a home. The humidifier is designed for connection directly to a supply air duct for humidity on demand. The humidifier may be directly mounted to the air duct, or remotely from the air duct, with a steam hose connecting the humidifier to a distributor nozzle installed at the air duct. INCLUDED IN THE BOX • HM750 steam humidifier • H6062 HumidiPRO • Steam distributor nozzle • Rubber drain hose • LDPE water hose • Baffle (duct mount only) • Foam gasket (duct mount only) • Steam hose (wall mount only) • Fittings, hardware, and mounting template Home and Building Technologies In the U.S Honeywell. 715 Peachtree Street NE Atlanta. GA 30308 customer.honeywell.com ' U S. Registered Trademark © 2017 Honeywell International Inc. 33-00362-01 M . 11-17 Printed in United States SUBMITTAL SHEET Approval Service Tag No. Notes SPECIFICATIONS Operating Ambient Temperature 41 to 104 °F (5 to 40 °C) Power Supply 120 VAC or 240 VAC 50/60 Hz Power Consumption 1.5 KW on 120 VAC 3.0 KW on 240 VAC Amps 12 A Phase 1 Circuit Breaker Max Current 15 A Steam Output on 120 VAC: 3.85 lb/hr (1.75 kg/hr) 11 GPD on 240 VAC: 7.7 lb/hr (3.5 kg/hr) 22 GPD Max Static Pressure 2 in. w.c. positive backpressure 3 in. w.c. negative backpressure Size length ■ width x depth 18 x 10 x 7 in. 457 x 254 x 178 mm Weight 10 lbs. (15 lbs. when full) 4.5 kg. (7.0 kq. when full) i I 33-00362-01 January 24, 2018 0 City of Tukwila Department of Community Development ALLEN PATTON 3602 SOUTH PINE ST TACOMA, WA 98409 RE: Correction Letter # 1 MECHANICAL Permit Application Number M18-0008 DIECUT STICKERS - 345 ANDOVER PARK E Dear ALLEN PATTON, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - M DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient. (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) 1. Indicate where the exhaust shall be a minimum 10 feet above the fmish grade and shall not cause a nuisance to the public. Also show where the unit gravity drain to the exterior shall also be located where ice could form on walkways. Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Sincerely, 7-.)( Bill Rambo Permit Technician File No. M18-0008 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 1ERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0008 DATE: 01/30/18 PROJECT NAME: DIECUT STICKERS SITE ADDRESS: 345 ANDOVER PARK E Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: A-3 1111 Building Division Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator w PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 02/01/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03/01/18 Approved Corrections Required ❑ Approved with Conditions ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 PERMIT CORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0008 PROJECT NAME: DIECUT STICKERS SITE ADDRESS: 345 ANDOVER PARK E X Original Plan Submittal Response to Correction Letter # DATE: 01/16/18 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: A-3- cmc Building Division Public Works 4 --AA &)/4 Hole Fire Prevention Planning Division Structural ❑ Permit Coordinator M PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 01/18/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 02/15/18 Approved Corrections Required ❑ Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only (� CORRECTION LETTER MAILED: 1.414 ''I �J Departments issued corrections: Bldg Fire ❑PinS❑ PW 0Staff Initials: 12/18/2013 0 d City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: M1 8-0008 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Diecut Stickers Project Address: 345 Andover Park E Contact Person: ,4//&/V MT iI Phone Number: 'IS -1":"1\ Ck'ISA.n Summary of Revision: \ACYGS Q,\11 o:, % 'yaw \\a J \cANZi.n ,C ‘2,1 \' RECEIVED CITY OF TUKWILA JAN 3 0 2018 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of re�vis''on Received at the City of Tukwila Permit Center by: N --centered in TRAKiT on is -10-1S \applications\forms-applications on line\revision submittal Created: 8-13-2004 Revised: AIR SYSTEMS ENGINEERING I Hoene Espanol Contact Safety & Health Claims & Insurance CoWashington State Department of Labor & Industries Page 1 of 3 Search L&I A-% Index Help My 110 Workplace Rights Trades & Licensing AIR SYSTEMS ENGINEERING INC Owner or tradesperson CRAWFORD, KANDI K Principals CRAWFORD, KANDI K, PRESIDENT CRAWFORD, DOUGLAS D, VICE PRESIDENT GEORGE, WILLIAM, VICE PRESIDENT COLYER, SANDRA K, SECRETARY ANDERSON, CURTIS M (End: 01/07/2010) ANDERSON, LORINE (End: 01/07/2010) WA UBI No. 600 099 211 3602 S PINE ST TACOMA, WA 98409-8197 253-572-9484 PIERCE County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. AIRSYE*229KN Effective — expiration 05/15/1978— 02/01/2020 Bond FIDELITY & DEPOSIT CO OF MD Bond account no. 08358752 $12,000.00 Received by L&I Effective date 01/27/2010 02/01/2010 Expiration date Until Canceled VIGILANT INS CO $12,000.00 Bond account no. 82138376 Received by L&I Effective date 02/04/2008 02/01/2008 Expiration date Until Canceled Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600099211 &LIC=AIRSYE*229KN&SAW= 2/2/2018 Ductless •Split System Air Conditioning Outdoor Unit Sahedule I.D. No. Area Served Mfr. Model. Refrigerant Cooling Capacity Electrical Data Op. Itlit. Line Set Total SEER Voltage Ph. MCA MOCP Printers & Equipment Fujitsu R-410a 33,000 15.5 208 1 23 30 134 3/8 x 5/8 HP-1 FAOU36RLXB Ductless Split System Indoor Unit. Schedule T.D. No. Area Served Mfr. M el ].:ierftaI Data will Mount Controller op. wt: Voltage Ph. MCA MOCP FC-1 PrihtersEquipment F ' su EC_ torutn 1 /3 :from o_d_ wit & install gromd 31 FASU36R=3 Cookig onl Unit to be ouration set in„Eeki drained to outsid anct located where ice could and is FC-1 Indoor wit powered by AC-1 condensmg AC-1 Condensing mit Sound pressure ievel 55 dB(A) FILE COPY Permit No. Mr6- 006 Plan review approval 13 subject to errors and omissions. Approval of construction documcnto does not authorize the violation of any adopted codcr crincnco. Receipt of approved Field Copy and itione is ao:(nowladged: By: Date: City of Tukwila BUILDING DIVISION SEPARATE PE;17;IT REQUIRED ;7(27:: CI echanical bd Electrical ErPlumbing 113/Gz..,sPip . *v... •• i REVISIONS No changes shall hl made to the scope. of work withr.-, ; prim approval of • . Tti!‘.',/ila 1-0!''''''''7.1r.'vi7,ictri ' .... •• ,: . NOTE: f7.-Y'.--• - - ,-r.' 4.17•74,1901 PROVIDE NEW X 5 FOOT1NOS PRQV1 FOR N POOR CijCLi A ' X VPAP EXTERIOR WALL ASSEMBLIES: Energy Recovery Ventilator Schedule , I.D. No. Area Served Mir. Model CFM Max ESP Nominal Recovery Effectiveness (Extra High Fan Speed) Electrical Data Op. 73 Wi. lbs Temperature Recovery Enthalpy Cooling Enthalpy Heating Voltage Ph. MCA MOCP ERV-1 Printers & Equipment Lossnay LGI-1-1900RX5-E1 300 0.78 66% 50% , 63% 208-230 1 1.7 15 Ventilation Schedule per 403.3.1.1 Equipment I.D. Space Occupiable Ft2 Occupancy CFM/Person CFM/Ft2 Effectiveness CFM Required CFM Provided ERV-1 Printers &. Equipment 500 13 14.62 0.38 0.5 190.0 200.0 Humidifier I.D. No. Mfr. Model Operating Temp Power Supply Amps Phase MOCP Weight HEVI-1 Honeywell HM750A1000 41° to 104° 120 or 240 vac 12 1 15A 10 lbs Steam Output 240 vac 7.71bihr; 22 GPD DETAIL . 1/A42 INTERIOR IOR WAI I -5/8" GYPSUM BOARD W1 (WITH 1" TYPE S DRYWALL SCREWS 8" 0.C. AT VERTICAL JOINTS AND 12"0.C. AT FLOOR AND CEILING RUNNERS AND INTERMEDIATE STUDS. TYf'.) i -3 1/2" METAL STUDS @ 16" O.C. - SOUND BATT INSULATION . , 2-5/8" GYPSUM BOARD DETAIL 2/A4,2 PLUMBING WALL i 5/8" GREENBOARD (INTERIOR FACE) W2 (WITH 1" TYPE S DRYWALL SCREWS 8" O.C. AT VERTICAL JOINTS AND 12" O.C. AT FLOOR AND CEILING RUNNERS AND INTERMEDIATE STUDS, TYR) -5 1/2" METAL STUDS @ 16" 0,C. 5/8" GWB r, PERIMETER WALL -5/8" GYPSUM BOARD W3 (NAIITH 1" TYPE S DRYWALL SCREWS 8" O.C. AT VERTICAL JOINTS AND 12" O.C. AT FLOOR i fr Tripir 'Ir Y 7- A. A. Atli. A A Ai AND CEILING RUNNERS AtsID INTERMEDIATE STUDS. TYP.) -5 1/2" METAL STUDS a) 16" Q.C. - R-21 SOUND GATT INSULATION GYPSUM BOARD -5/8" -EXISTING CONCRETE WALL NOTE: GWB TO 1 0'-0" A.F.F (INSULATION EXPOSED ABOVE) NOTE: ALL WALL HEIGHTS AT 101-0" AF.E, U.O.N. Exhaust shall be a minimum 10 feet above the finish grade and shall not cause a nuisance to the public Minimum clearance in between intake and exhaust for ER re--10.0 ft ,1 • Av.mavitomomix..w.4:%374..w.iv"vc.wmolswkw Humidifier FC-1 Controller ERV Controller FLOOR PLAN AREA OF WORK NTS , SHOWN ON PRINT IN FEET & INCHES V.47.4..!• AlArt,7,,AW.4.5X160=7,47 TaNt!Tivi,Nrateig .M.'317teethroW47,17,4WirileMPAWaldre741,VINIMI94, FC-1 , In oor high wall Scope of Work: • Furnish and install (1) 3 ton new Fujitsu wall mount air conditioner for printer room. • Furnish and install (1) new wall mount Honeywell brand humidifier for maintaining adjustable humidity within reason 40- 50%rh. • Furnish and install (1) Lossnay brand 300 cfm ERV system for exhausting odor of new printer. • Furnish (1) 115V service receptacle for outdoor condensing unit per code. • Provide electrical circuits for the HVAC unit, Humidifier, and ERV. Includes installing new disconnect boxes/switches, fuses, and electrical whips. •Core drilling holes for outdoor unit and ERV system. Vicinity Map No Scale RECEIVED CITY OF TUKWILA JAN 30 2018 PERMIT CENTER PARCEL # o2234o REVISIONS MECHANICAL PERMIT CORRECT CO C. \I C\ CID Ct 00 44 00 Ct C\ P.1 4t O • ct • r-‘ Cr) RE\ IEWED FOR ODE COM '3LIANCE 4 PROVED D04DEB a 1 F1118 Pr3 City of Tt tvita BUILDING DIVISION E, 0 '40 C:4 0) c 44 r,) 44 rn 04 44 r7i ••C r4 44 r:4 4.4 1:4 •'4 r.)