HomeMy WebLinkAboutPermit M18-0009 - SEATAC LIGHTING - HEAT PUMP, A/C EXHAUST FAN & DUCTING, THERMOSTATSSEATAC LIGHTING 15455 53 AVE S EXPIRED 01/07/19 MI 8-0009 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Aov MECHANICAL PERMIT 1157200044 Permit Number: M18-0009 15455 53RD AVE S SEATAC LIGHTING Issue Date: 2/21/2018 Permit Expires On: 8/20/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: SEA -TAC LIGHTING CORPORATE 15455 53RD AVE S , TUKWILA, WA, 98188 JOHN MERRILL Phone: (253) 831-4446 MECHANICAL & CONTROL SRVCS INC Phone: (253) 926-9777 (GENERAL) 6426 18TH ST E , FIFE, WA, 98424 MECHACS962BT Expiration Date: 2/26/2018 6426 18TH ST E , FIFE, WA, 98424 DESCRIPTION OF WORK: INSTALL (1) 5 -TON SPLIT HEAT PUMP IN CONFERENCE ROOM. INSTALL (1) 1 -TON SPLIT A/C IN SERVER ROOM, INSTALL (1) EXHAUST FAN & DUCTING IN RESTROOMS. INSTALL (1) EXHAUST FAN IN BREAK ROOM. INSTALL (4) THERMOSTATS. MODIFY & INSTALL NEW DUCTING TO ACCOMODATE NEW FLOOR LAYOUT. Valuation of Work: $45,000.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $821.05 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signature: Date: 1-.2/•16 e I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: ""-+ ^ a,i Date: Z/Z//%"" This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 1800 0609 0705 0701 MECH EQUIP EFF MECHANICAL FINAL PIPE/DUCT INSULATION REFRIGERATION EQUIP ROUGH -IN MECHANICAL a separate permit issued by the City of Tukwila the job site at the time of inspection. CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. M ( 0-- 0007 Project No. Date Application Accepted: Date Application Expires: .1l r.1 Qj (For office use only) lV/ MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 115720-0044 Site Address: 15455 53RD AVE S, TUKWILA, WA 98188 Suite Number: Floor: Tenant Name: FOSTER FURNITURE New Tenant: 0 Yes ❑..No PROPERTY OWNER Name: SEA -TAC LIGHTING CORPORATE Address: 4439 S 134th P1 Bldg E City: TUKWILA state: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: JOHN MERRILL Address: 6426 18TH ST E City: FIFE State: WA Zip: 98424 Phone: (253) 831-4446 Fax: (253) 926-9222 Email: JOHNM@GROUPMCS.COM MECHANICAL CONTRACTOR INFORMATION Company Name: Mechanical & Control Services Address: 6426 18th ST E City: FIFE State: WA Zip: 98424 Phone: (253) 926-9777 Fax: (253) 926-9222 Contr Reg No.: MECHACS962BT Exp Date: 02/26/2018 Tukwila Business License No.: 0997334 Valuation of project (contractor's bid price): $ 45,000 Describe the scope of work in detail: INSTALL (1) 5 -TON SPLIT HEAT PUMP, CONFERENCE ROOM. INSTALL (1) 1 -TON SPLIT A/C, SERVER ROOM. INSTALL (1) EXHAUST FAN & DUCTING, BATHROOMS. INSTALL (1) EXHAUST FAN, BREAKROOM. INSTALL (4) THERMOSTATS. MODIFY & INSTALL NEW DUCTING TO ACCOMMODATE NEW FLOOR LAYOUT. Use: Residential: New 0 Replacement 0 Commercial: New Replacement 0 Fuel Type: Electric 0 Gas Other: H:\Applicatioos\For sApplications On Line 2016 Applications\Mc dmical Permit Application Revised 1-416.docx Revised January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Fumace <100k btu Residential, Nighttime Furnace >100k btu 1 Floor furnace 4 Suspended/wall/floor mounted heater 2 Appliance vent Commercial Repair or addition to heat/refrig/cooling system 3 Air handling unit 65 dB(A) <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfin 1 Evaporator cooler 4 Ventilation fan connected to single duct 2 Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 4 Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu Residential, Nighttime 3-15 hp/500,000 btu Industrial 15-30 hp/1,000,000 btu 55 dB(A) 30-50 hp/1,750,000 btu 57 dB(A) 50+ hp/1,750,000 btu Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-lOpm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Mailing Address: 6426 18TH ST E H:1ApplicationsWorms-Applications On Line \2016 Applications\Mechanical Permit Application Revised I-4-16.docx Revised: January 2016 bh Date: 01/17/2018 Day Telephone: (206) 4724068 FIFE WA 98424 City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK 1 M18-0009 Address: 15455 S3RD AVE 5 n: 1157200044 21. Credit Card Fee Credit Card Fee R000.369.908.00.00 0.00 $23.91 $23.91 MECHANICAL $766.48 PERMIT ISSUANCE BASE FEE PERMIT FEE PLAN CHECK FEE R000.322.100.00.00 R000.322.100.00.00 R000.322.102.00.00 0.00 0.00 0.00 $33.15 $580.03 $153.30 TECHNOLOGY FEE $30.66 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R13446 R000.322.900.04.00 0.00 $30.66 $821.05 Date Paid: Wednesday, January 17, 2018 Paid By: JOHN PARKS Pay Method: CREDIT CARD 117165 Printed: Wednesday, January 17, 2018 9:56 AM 1 of 1 I?SYSTEMS INSPECTION RECORD Retain a copy with permit Mig-oret9 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Pr ect: T.40, / ,ii,j4c Typeluof Inspection Address: �/ Specia Date Called: Instructions: Date Wanted: 7^IC- a.m. p.m. Requester: 3-ei F Bird Phone No: 253-3552 3 ElApproved per applicable codes. LJ Corrections required prior to approval. 1.76.0e, 'LL Date:7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 ProjSeedLI Ty eC . Address: 51/s5 53—Y 0 Date Called: C---..., pecial Instructions: Date me : e zoite . p. . Requester: J ac Phone No: 2-x3-370 0194 Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: R-5 C-tkaGcle___ /11(ANA4 Atir 2-3-3ss= zs Acsor Trtry4-3/ (Zan/es Inspector: Date: n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit M 1,$-ooCq INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pra'e I. + Ty4 i of Ins ection: Address:'16 (sy55 53 Avcc .. Date all d: Special Instructions: Date Wanted ~ r -� a.m. p.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Inspector: non92___ Date 3-�� REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit IN ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION M1?-oc1 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: S —t-4 e • / % of Inspection: ,,,,® eI ^l t LC VllA41 (CA/Address: 151/5553 p fie.S, Date ed:p0�4{f1l Special Instructions: Date Wanted 9 -3 - ZOJg' p.m. Requester: Phone No: ❑ Approved per applicable codes. L1 Corrections required prior to approval. COMMENTS: eRizekI "l / ir-dip41 i CSL - ?lop Inspector: gs 0 Date: L/ 5 _ 2018 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. d INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 W► I$ -oO'Oq Project: Ty a of Inspection: Cull CAA 4 Address: /4.5X5:5- 53R49 Ng , , Date Called: Special Instructions: "160 -/11/ MACHiet-A sC/ Date Wanted: L 3 -Agfa 6.m p.m. Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: 0d/140116w Rovth. 7A) - 4-;11- /iced --bemSrr��dueturrriX- a�a (Prsk IebDWI 4/Z$, Ay I- LeA nl.,ar sem.- �-lc. Inspector: Q n Capt.) Date:2 G Zv REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. d INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 MIT -0009 Project;— C x 1�G Lt -�- rg Type of Insoecti I Aieeh Pet', 7 Address: U /544s-5 Sa Avcs. Date Called: �j/J Special Instructions: Date Wanted: 3- 23- 2.40,8- a.i p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMM /) /(%e.42, ,' s7L' c; i Strfi as /% ofid 7- Y 2) } e c elk e i V k Dice ui- /D L,,rc fS di ,_5 -cd•- kCog- Ate -L/1 r REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 12/2/2018 JOHN MERRILL 6426 18TH ST E FIFE, WA 98424 City of Tukwila Department of Community Development RE: Permit No. M 18-0009 SEATAC LIGHTING 15455 53 AVE S Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 1/7/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 1/7/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, achelle Ripley Permit Technician File No: M 18-0009 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 January 23, 2018 JOHN MERRILL 6426 18TH ST E FIFE, WA 98424 City of Tukwila Department of Community Development RE: Correction Letter # 1 MECHANICAL Permit Application Number M18-0009 SEATAC LIGHTING - 15455 53 AVE S Dear JOHN MERRILL, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - M DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient. (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) 1. Please provide full size plan sheets that are to scale. Reduced sheets are not to scale, are difficult to read and shall not be accepted. 2. All plan sheets with engineer's stamp and signature shall include the dated of the signature. See General Note above. Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Far 206-431-3665 Sincerely, ?o,L Bill Rambo Permit Technician File No. M18-0009 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY 0 PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0009 DATE: 02/12/18 PROJECT NAME: SEATAC LIGHTING SITE ADDRESS: 15455 53RD AVE S Original Plan Submittal Revision # before Permit Issued Revision # after Permit Issued X Response to Correction Letter # 1 DEPARTMENTS: Building Division Fire Prevention Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 02/13/18 Structural Review Required REVIEWERc INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: Approved ❑ Approved with Conditions Corrections Required ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: 03/13/18 REVIEWERc INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 © 4 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0009 DATE: 01/17/18 PROJECT NAME: SEATAC LIGHTING SITE ADDRESS: 15455 53 AVE S X Original Plan Submittal Response to Correction Letter #, Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator 1 PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 01/18/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Review:sr DUE DATE: 02/15/18 Approved with Conditions ❑ Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg t Fire 0 Ping 0 PW 0 Staff Initials: 3e 12/18/2013 c City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 2 / / Plan Check/Permit Number: / /(5— — 000 ❑ Response to Incomplete Letter # Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: S e < Project Address: /5Y 53 r 4 S Contact Person: :704- �/ S Phone Number: Summary of Revision: RECEIVED CITY OF TUKWILA FEB 0 9 2018 PEHMIT CtNTE1 Sheet Number(s): "Cloud" or highlight all areas of revision includin dat of r ision Received at the City of Tukwila Permit Center by: Ak [l Entered in TRAKiT on W:\Permit Center (Brenda)\Forms'Permit Center Documents (Word)\Revision Submittal Form.doc Revised: August 2015 MECHANICAL & CONTROL SR6S INC �I Washington State Department of Labor & Industries Hone Espanol Contact Safety & Health Claims & Insurance Search L&I Page 1 of 3 APH, A -Z IRIex lIelp My 1,10 Workplace Rights Trades & Licensing MECHANICAL & CONTROL SRVCS INC Owner or tradesperson Principals Hull, Travis Edward, PRESIDENT Hunt, Ted Lamond, VICE PRESIDENT HULL, ANGELA DAWN, SECRETARY GROVER, HAROLD, VICE PRESIDENT (End: 02/26/2010) DICKSON, PAUL, TREASURER (End: 02/26/2010) Doing business as MECHANICAL & CONTROL SRVCS INC WA UBI No. 602 338 440 6426 18th St E FIFE, WA 98424 253-926-9777 PIERCE County Business type Corporation Governing persons ANGELA DAWN HULL TRAVIS EDWARD HULL; License Verify the contractors active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. MECHACS962BT Effective — expiration 01130/2004— 02126/2018 Bond American Contractors Indem CO Bond account no. 100239439 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 02110/2014 02/06/2014 Expiration date Until Canceled Bond history Insurance Continental Insurance Co Policy no. 6023856626 $1,000,000.00 Received by L&I Effective date 01/18/2018 01123/2018 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602338440&LIC=MECHACS962BT&SAW= 2/20/2018 DEDICATED OUTSIDE AIR SCHEDULE TAG LOCATION SERVES TYPE ERV EFFECT (%) SUPPLY FAN PERFORMANCE EXHAUST FAN PERFORMANCE ELECTRICAL DATA SOUND RATING (DBA) WEIGHT (LBS) (C' BRAND MODEL NOTES CFM ESP (IN.WG) DRIVE BHP CFM ESP (IN.WG) DRIVE BHP V/PH/HZ FLA MCA CIRCUIT AMPS (b) DOAS-1 STORAGE 170 TRAINING/CONF HORZ 70 450 0.3 ECM - 450 0.3 ECM - 208/3/60 4.8 6.0 15 - 202 RENEWAIRE EV4SOIN 1 Footnotes - (a) Circuit breaker or MOCP amps. Notes: 1. Energy recovery ventilation unit (ERV). Operate continuous during occupied hours. Provide field installed bypass duct, damper and controls for economizer operation. SEC: C403.6, C403.6.1, C403.5.1. OR EQUAL. Pump)AIR HANDLING UNIT SCHEDULE (Heat TAG LOCATION SERVES OOHS TCFM TYPE FAN PERFORMANCE AUX HEATER KW ELECTRICAL DATA WLgSHT BRAND MODEL NOTES NOTES ESP (IN.WG) MOTOR HP DRIVE V/PH/HZ FLA MCA CIRCUIT AMPS (a) AH -1 STORAGE 166 TRAINING/CONFERENCE 5 HORIZ 2,000 0.40 3/4 DIRECT 13.5 208/3/60 45 55.5 60 207 CARRIER FV4CNB006 1 Footnotes - (a) Circuit breaker or MOCP amps. Notes: 1. Variable speed ECM motor, electric strip heat, DX coil with TXV & factory air filter. VERIFY ELECTRICAL. HEAT PUMP OUTDOOR UNIT SCHEDULE TAG LOCATION NOM TONS TC (a) (MBH) SEER OR EER HIGH HEAT (MBH) COP HSPF ELECTRICAL DATA V/PH/HZ FLA MCA CIRCUIT AMPS (b) SOUND RATING (DBA) WEIGHT (LBS) BRAND MODEL NOTES HP -1 ROOF 5 57.0 14.0 54.5 3.7 8.2 208/3/60 17 21.5 30 76 202 CARRIER 25HCE460A 1 Footnotes - (a) Total cooling 95F outdoor ambient. (b) Circuit breaker or MOCP amps, Notes: 1. Low ambient to 15 deg F outside. DUCTLESS HEAT PUMP OUTDOOR SCHEDULE TAG LOCATION NOM TONS(MBH) TC(a) SEER HIGH HEAT (MBH) HSPF ELECTRICAL DATA SOUND RATING (DBA) WEIGHT (LBS) BRAND MODEL NOTES V/PH/HZ FLA AMPS (b) HP -2 ROOF 1 12.0 26.1 21 12.5 208/3/60 11 15 51 83 MITSUBISHI MUZ-FH12NA 1 HP -3 ROOF 1 12.0 26.1 21 12.5 208/3/60 11 15 51 83 MITSUBISHI MUZ-FH12NA 1 Footnotes - (a) Total cooling 95F outdoor ambient. (b) Circuit breaker or MOCP amps. Notes: 1. REFER TO MANUFACTURER FOR REFRIGERANT PIPE SIZES. NO ECONOMIZER PER EXCEPTION #3, WSEC C403.3 DUCTLESS HEAT PUMP FAN -COIL SCHEDULE TAG LOCATION NOM TONS TYPE FAN PERFORMANCE ELECTRICAL DATA WEIGHT (LBS) BRAND MODEL NOTES CFM ESP (IN.WG) DRIVE V/PH/HZ FLA MCA CIRCUIT AMPS AH -2 P. OFFICE 128 1 WALL 350 FREE BLOW DIRECT FROM OUTDOOR UNIT 29 MITSUBISHI MSZ-FH12NA 1 AH -3 P. OFFICE 180 1 WALL 350 FREE BLOW DIRECT FROM OUTDOOR UNIT 29 MITSUBISHI MSZ-FH12NA 1 Notes: 1. Provide factory thermostat to match equipment. PROJECT LOCATION VICINITY MAP SCALE: NONE LOCAL MAP SCALE: NONE SE. -T:, .:.i E PERMIT FOR: �Q, �Machanical (�' ! lectricai lG' ambing as Spina City of Tukwila BUILDING DIVISION REVISIONS No changes Sha`! hr made to the scope # \T)ri i,oii 3'O+zt prior approval of �'r k',�aa Ew�3di g Division_ t' e 9 c.;xu :�.. �.m.. a n . plan submittal and weal adairmal pia review fees. FILE COPY Permit No.. Nt(- do0% Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: By: Date: 2/2 ///g' City of Tukwila BUILDING DIVISION TAG EQUIPMENT SCHEDULE EF -1,2 EXHAUST FAN, Ceiling type, 100 cfm @ 0.250" SP, 1.3 sones, Operate thru wall switch in room. Broan L100. Electrical data: 120/1/60, 1 amps. EF -3,4,5 EXHAUST FAN, Ceiling type, 200 cfm @ 0.250" SP, 2.9 sones, Operate thru wall switch in room or central timer for occupied hours. Broan L250. Electrical data: 120/1/60, 2 amp. TAG CONTROLS T1 SEVEN DAY PROGRAMMABLE THERMOSTAT, two stage, Honeywell TB8220. OS OCCUPANCY SENSOR, Wall mount. Runs DOAS unit when motion is detected. A delayed OFF adjustment (up to 20 min.) prevents unit from switching OFF when space is occupied. Hubbel #WS1001W. WSEC C403.2.6.3 M1 MOTORIZED DAMPER, two position, spring return actuator with low leak damper. Actuator: Belimo LF120 (120 volt) or LF24 (24 volt). Damper: Ruskin CD -60 (Class 1A low leak rated). WSEC C403.2.4.3 CONTROL NOTES 1. System capable of minimum 5 degree deadband, seven day programmable for each day per week, outside air dampers close automatically when system is off or upon power failure, interlocked to prevent simultaneous heating and cooling. 2. Mount thermostat or sensor 60 inches above floor. CONTROL SEQUENCE MOTORIZED EXHAUST AIR DAMPER Provide class 1 motorized damper on exhaust air opening which close damper when fan is off, open during occupied hours. WSEC C403.2.4.3. VENTILATION CALCULATION SPACE TYPE AREA (SF) OSA (CFM/SF) # PEOPLE OSA (CFM/PERSON) TOTAL OSA (CFM) CONF. RM 1720 0.06 69 5 448 OFFICE 128 264 0.06 1 5 21 OFFICE 180 244 0.06 1 5 20 co ub i 0 SYSTEM DESCRIPTION T.I. to existng building. Installing new split system, heat pump, DOAS and Exhaust fans. HVAC DRAWING INDEX M1.0 HVAC Schedules and Legends M1.1 HVAC Schedules & Site Plan M2.0 M2.1 HVAC Floor Plan Roof HVAC Plan HVAC LEGEND SYMBOL AH -1 =1, --r- r FC ABBV. DESCRIPTION Control Equipment Grille/Louver Supply Duct Return/Exhaust Duct Duct under slab (Spunstrand) Flex Duct, insulated, inside dimension Metal Duct SL Soundlined Duct VD Volume Damper Flex Connector TV Turning Vanes End Cap Change in duct size Surface Mount Supply Grille T -bar Supply Grille Round Supply Grille Return/Exhaust Grille Sidewall Supply/Makeup Grille Sidewall Return/Exhaust Grille FD Floor Drain AFF Above Finished Floor AT Air Transfer BS Birdscreen OSA Outside Air RA Return Air SA Supply Air -+-- z O z O GRILLE CALL OUT LEGEND Neck Size (IN) Square or Rectangular Grille Tag Number of Slots Grille Tag 8/8 8 140 1S(0.5) 2 100 Neck Size (IN) Round Air Quantity (CFM) Indicates Slot Type Grille Slot Size (IN) Length (FT) Air Quantity (CFM) Air Pattern - indicated by arrows for ceiling grilles. No Arrows indicated four way pattern. DUCT CALL OUT LEGEND (Example call -out shown) 14/10-1 Lined metal duct, outside duct size given. Number after dash is iiner thickness (in.). REVIEWED FOR CODE COMPLIANCE APPROVED FEB 1 6 Z010 CItVG 14/10 Metal duct size. 14 Round metal duct. 14/10 FO Flat oval duct. 1 1/2 HR. "UL" Dynamic Fire Damper. UL 555. Ruskin DIBD2 or equal. R "UL" Ceiling Fire Damper for up to 3 hr. rating. UL 555C. Ruskin CFD or equal. 1 1/2 HR. "UL" Combination Fire -Smoke Damper with 115 volt connection to smoke detection system. Class II, 250°F. UL 555 & UL 555S. Ruskin FSD36 or equal. C 1 HR. "UL" Corridor Combination Fire -Smoke Damper with 115 volt connection to smoke detection system. Class II, 250°F. UL 555 & UL 5555. Ruskin FSD36-C or equal. S Smoke Damper, "UL" rated, with 115 volt connection to smoke detection system. Class II, 250°F. UL 5555. Ruskin SD36 or equal. 1 1/2 HR. "UL" Combination Fire -Smoke Damper with grille access and 115 volt connection to smoke detection system. Class II, 250°F. UL 555 & UL 555S. Ruskin FSD36GA or equal. NOTE: All fire/smoke dampers to be installed per manufacturer's 'UL' instructions and shall have permanently labeled access door per 2015 IMG2;�TY , RECEIVED sec. 607.4. OIr T Ur dVILA 4 FEB 0 9 2013 DRAWING DISCREPANCIES PERMIT CENTER Contractor to alert Franklin Engineering of any discrepancies found on the drawings, such as missing data, typos, or any other items that do not make good sense. CODES 2015 Washington State Energy Code 2015 Washington State Building Code 2015 International Mechanical Code 2015 International Building Code CORRE LTR# N I`6/ 00(1 I gANKLI�r �c�4Art, 4 ��of AAso/4, *:„ ',yr , " ' sa"6\s,14.;0GNIAsTi.7.0C$ 13387 ,��CC4vV� 625 FOURTH AVE "`°` SUITE 202 FRANKLIN KIRKLAND, WA 98033 TEL 425/521-3324 ENGINEERING ;=AX 425/021-6252 MECHANICAL CONSULTING www.franklineng.com CLIENT: �` Mr `MECHANICAL .; CONTROL SERVICES, INC SEATAC LIGHTING 15455 53rd Ave S Tukwilla, WA 98188 HVAC Schedules & Legends WA.. • .a..- ., m: w PERMIT SET 1._ AN 07 .Th3 DRAW DESIGN: co ub i 0 JOB NO. 71210 SHEET ..Q E a N LA 0 0 i i i r I I i 11 -2 C' TAG GRILLE AND LOUVER SCHEDULE HVAC GENERAL NOTES SUPPLY: 1. VERIFY site conditions. 2. THERMOSTAT LOCATIONS: Verify all wall mounted control locations with A Square Ceiling Diffuser, Modular core, Surface frame type 1, with OBD, Titus MCD. architect. 3. CODES: Comply with all local & state governing codes. B Louvered, Double deflection, Titus 300RS, with OBD. 4. COORDINATE ductwork and grille locations with lighting and other related trades with architect approval. Verify clearances & ceiling elevations before installation. C Not used 5. DRAWINGS are schematic in some areas and may not show exact routing or every offset which may be required. Provide a complete & properly working system with RETURN/EXHAUST: all necessary items. 6. SEISMIC BRACING: Provide to meet local code requirements. Refer to the ASHRAE D Standard fixed blade, Titus 350RL. standards "Practical Guide to Seismic Restraint", 1999. 7. PIPING INSULATION: Provide thermal insulation as required on HVAC piping. For E Eggcrate, aluminum grid 1/2", T -bar frame type 3, Titus 50F. exterior piping include protection from weather and damage. WSEC, sec. C403.2.9 8. EXHAUST FAN TERMINATION: Shall not be less than 3 feet from a property line or F Not used openings into a building, e.g., operable windows and doors. IMC, sec. 501.3.1, item #3. ROOF CAPS AND WALL VENTS: 9. CONDENSATE DRAINS: Run 3/4" PVC pipe from cooling coil to nearby open site drain or to outside planting bed on ground. Elevate coil to allow for proper gravity G Roof cap, globe style vent with birdscreen, round galvanized, FAMCO #G BV drain operation. Provide approved "P" trap at coil outlet. IMC, sec. 307. 10. TEST, ADJUST, & BALANCE: Provide proper system testing, adjusting, and GENERAL GRILLE NOTES: balancing on both air and water according to NEBB & ASH RAE standards, including 1. All steel construction except as noted. 2. Standard white finish except as noted. PRIVATE ROAD 1T__L 7 PROPERTY LINE 53RD AVE S. i i LOADING DOCK EXISTING WALKWAY FLUSH WITH PAVING (6) EXISTING PARKING STALLS TO BE CONVERTED TO ACCOMMODATE (3) NEW ADA PARKING STALLS & (1) ADA VAN STALL; RESTRIPE ADA PAINT ADA SIGN ON FLOOR VERIFY AND/OR PROVIDE 5-0' WIDE CROSSWALK STRIPING 70 ACCESSIBLE PARKING; MAXIMUM 2% CROSS SLOPE EACH WAY/ 5% RUNNING SLOPE IN DIRECTION OF TRAVEL a r�� V) / (N i � FORVAN\ j40 !!I DASH LINES INDICATE EXISTING PAINT STRIPE TO BE DEMOLISHED EXISTING ROCKERY WALL 3-4' H AT EACH ACCESSIBLE PARKING PROVIDE SIGNAGE IN FRONT OF EACH STALL AS REQUIRED. REFER TO DETAIL 9/19.7 SITE PLAN SCALE: NTS i J written reports. Use only technicians qualified & trained in TAB work. Include System Commissioning: Functional testing of sequences of operation to ensure they operate in accordance with the mechanical plans. (WSEC, Sec C408). Work by NEBB certified firm. 11. OPERATION & MAINTENANCE BOOKLET: Provide 0 & M manual to owner. Include cut sheets on main equipment and controls, maintenance instructions, and marked up as built drawing (record drawings per WSEC, Sec C408). 12. WALK-THRU instruction: Provide on site walk-thru for customer to demonstrate operation of system and answer questions. 13. ELECTRICAL: All equipment to have a positive means of disconnect adjacent to and in sight from equipment served. Provide a 120 volt receptacle located within 25 feet of equipment for service & maintenance purposes (IMC sec. 301.10). Line voltage work by others. DUCT NOTES 1. DUCT CONSTRUCTION and installation per latest SMACNA Standards and the IMC as required by the local code. Provide metal duct, except as noted. Underground duct shall be "Spunstrand" factory insulated fiberglass construction. 2. BALANCING DAMPERS: Provide on all supply grille run out ducts up stream of grille. 3. DUCT INSULATION: Manville fiberglass duct wrap, type 75, FSK aluminum foil facing or equal. Outside air ducts in conditioned space = R-7 with vapor barrier; Supply & return: in unconditioned space = R-6, outside building envelope = R-8. EXCEPTIONS: No insulation required where the design temperature difference between interior and exterior of the duct does not exceed 15°F. Supply ducts which convey supply air at temperatures less than 55°F or greater than 105°F shall be insulated with min. R-3.3 insulation where located within conditioned space. WSEC sec. C403.2.8 4. DUCT SEALING -GENERAL: 0 to 2" static pressure - seal all seams and joints on all ducts. Higher static pressures - refer to the IMC for additional requirements. Inside build: DuroDyne "DDS -181 "gray or approved equal per UL 181 A -M, 181B -M listed. Outside: Polyurethane, Mameco Vulkem 116. OR approved equal. WSEC sec. C403.2.8 5. TURN VANES: Provide single thickness turn vanes (see detail) in all major square duct elbows, tees, or turns with inside radius less than 3/4 duct width. Square branch duct taps shall be 45 degree type per SMACNA standard. 6. FLEX DUCT (Insulated): For grille run outs up to 6 ft. long, except as noted. Provide adjustable metal elbows on all turns, unless a smooth full radius turn is made. Secure core with approved nylon or metal worm drive clamps. NO duct tape joints & screws allowed. 7. SOUND LINER: Provide sound lined metal supply & return ducts as shown on plans. Johns Manville Linacoustic RC flexible fiberglass liner with Permacote acrylic surface treatment or equal. Fabricate and install per duct liner standard of North American Insulation Manufacturer's Assoc. 8. FLEX CONNECTORS: Provide on all duct hook-ups to isolate air handling equipment (Neoprene coated fiberglass fabric type). 9. DUCT SIZE CHANGES: Round galvanized ducts may be substituted for rectangular ducts that are NOT LINED. Provide circular equivalent of rectangular duct. Other equivalent rectangular duct sizes may be substituted to better fit space. 10. TEMPORARY DUCT CLOSURE: Seal off ductwork during construction to keep out construction dust, especially floor boots and low wall openings. JAN O7.2OS J REVIEW FOR CODE COMPLIANCE APPROVED FEB 16 2013 City of Tukwila ik a. C RE CEi,y Y. ,) CITY OF T UK',ViLA FEB 0 9 2013 PERMIT CENTER „g,p,NKL jAr 441, •��44�� of wnsgf(ro ti , \ k 1 ty�,13387 O.4Ssio I S TEB S�'�.` NAL 625 FOURTH AVE CLIENT: ‘44/11,Alit Si C S CONTROL SERVICES, INC. Schedules & Site Plan rncc ran. --J 1 m d U- a PERMIT SET DRAWN: DESIGN: cc 6 0 JOB NO. 71210 SHEET E a 0 0 co 0 N 0 Q 0 4 e AIR SPACE OR PLEN M FOR MECHANICAL SYSTEM O LOADING DOCK 165 0 N STORAGE 1 164 STORAGE 166 18 O 0 O 0 J L_J 1, K=QOM 162 8" UP TO ROOF CAP 000 000 000 000 000 000 000 COLLABORATIVE WORK/LOUNGE 163 0 000 000 000 000 000 000 000 AH -1 3 FT. 1" SL ON HANG SUPPLY & RETURN DUCTS HALLWAY 172 L 11 BAR 173 �_J 30/24 14/12 14/12 12 TRAINING/ CONFERENCE ROOM 167 12/12 R3 500 Li (4X) 12 B 10/10 450 DOAS-1 HANG 0 0 STORAGE 170 10 UP TO ROOF CAP, TYP. GAME ROOM 160 EF -4 MOP 1 158 EF— EF-2 SAMPLIIlIC-EF-3 WORKR 174 1 WAR ROOM 155 0_Q MOTHER'S ROOM 154 CLOSET 157 0 0 0 A RI MEN'S R/R 152 x liO. AD•• ;6I r V+ 'L F12" UP TO 12 WO e=n"RIR �M1�" GOOF CSI ® 0 0 I 0 0 L—. SALES TEAM AREA 177 X CLOSET 106 7 I OPEN \ / I MEETING I��\ 1 103 1 17 lz \ 1 EXISTING HVAC TRUNK LINE COPY/PRINT 147 OPEN WORKSTATIONS 144 17N 71 I \\77 I 7\ I HALLWAY / / \ 1 i \ 149 1 SERVER/ STORAGE 141 I`\ //I I \\V I �\ I N. I I7 N. I �/ N. WAR ROOM 110 WAR ROOM j 111yj PRIVATE OFFICE 140 ADMIN OFFICE AREA 139 i LOCATION OF SKYLIGHT ABOVE 1 I \\7V I I, \ V\ I I 7\ I Iz OPEN WORKSTATIONS 115 OPEN COLLABORATIVE 118 I RECEPTION/ LOBBY 101 Q12/6 AT ADMIN 182 AH -3 WALL PR OFF VFTE OE 6/6 7t 6/6 180 ''100 OUTSIDE AIR PROVIDED FROM EXISTING HVAC HVAC FLOOR PLAN SCALE: 1/8"=1'-0" 1 138 Ii I`\ \\VV I I�\ I ,N. I V N. 1 Ez 'Ni LARGE CONFERENCE OPEN WORKSTATIONS EXISTING HVAC TRUNK LINE 134 SALES TEAM AREA ....) 130 6 12/6 AT El (E) 6/6 AH -2 WALL PRIVATE OFFICE NEW DISPLAY/ WORK COUNTER 125 OUTSIDE AIR PROVIDED — FROM EXISTING HVAC PROJ. MGR AREA 123 1 EXPI G' Vig lei I 6/6 X100 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 16 2fli City of Tukwila RECEIVED CITY OF TUKWILA FEB 0 9 2018 PERMIT CENTER vANKL IN., 4'4) 41. xasgf�� CS �r • .y, ft tib 14 ,st,15 13387, ,rt�$ � EGISTLO��.' SIGNAL 625 FOURTH AVE SUITE 202 CLIENT: �s"*'''g.° .G.- trt CHA ICAL. CONTROL SERVICES, INC. w ell r- 00 HVAC Floor Plan 6.VI cnrr r'....1 1 1 a L a PERMIT SET DRAWN: DESIGN: 00 0 JOB NO. 71210 SHEET M2.0 rA HP -1 WT=212 LBS o ©8''0 ROOF CAP 0 10"s6 ROOF CAP (2X) MIN. 10' SEP V A HP -3 WT=83 LBS. ROOF CAP 0 HVAC ROOF PLAN SCALE: 1/8".1'-0" HP -2 WT=83 LBS. EXHAUST TERMINATIONS Terminations to be 3 ft from property lines and operable openings into building. 10 ft from mechanical air intakes. 2015 IMC with WA State Amendments, Sec 501.3.1, #3 EXPI JAN 07_Blig IREVIRWED FOR C PE COMPLIANCE A‘"' V' ROVE D FEB 113 204 City of Tukwila RECEIVED CITY OF TUKWILA FEB 0 9 2018 PERMIT CENTER WAsiti4:44%." tiA ik* 13387 .44?0_4)RG STO9 625 FOURTH AVE = SUITE 202 FRANKLIN KIRKLA,ND, WA 95033 TEL 42/21-3324 ENGINEERING FAX 425/021-6252 MECHANICAL CONSULT NG WWw.frankl inert g.coni CLIENT: to, MECEIANICAL OONTROL SERVICES, INC „zoo SEATAC LIGHTING 15455 53rd Ave S Tukwilla, WA 98188 HVAC Roof Plan 1 `1-2 PERMIT SET DRAWN: DESIGN: 01-16-18 JOB NO. 71210 SHEET M 2 1