Loading...
HomeMy WebLinkAboutPermit M18-0011 - AIR WAVE EXPRESS - CONDENSING UNITAIR WAVE EXPRESS 1101 ANDOVER PARK W COMPLEX EXPIRED 07/25/18 M18-OO11 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 8836500110 Permit Number: M18-0011 1101 ANDOVER PARK W COMPLEX Issue Date: 1/26/2018 Permit Expires On: 7/25/2018 Project Name: AIR WAVE EXPRESS Owner: Name: Address: Contact Person: Name: AIRWAVE INVESTMENTS LLC 218 SW 299TH PL, FEDERAL WAY, WA, 98023 TAYLOR LOWERY Address: 1221 SECOND AVE N , KENT, WA, 98032 Contractor: Name: HERMANSON COMPANY LLP (GENERAL) Address: 1221 2ND AVE N , KENT, WA, 98032- 2945 License No: HERMACL005BJ Lender: Name: Address: /Il Phone: (206) 817-9099 Phone: (206) 575-9700 Expiration Date: 8/25/2018 DESCRIPTION OF WORK: DISCONNECT AN EXISTING BOILER AND REPLACE WITH NEW MORE EFFICIENT CONDENSING UNIT. DISCONNECT AND RECONNECT THE GAS AND ELECTRICAL SUPPLIES. Valuation of Work: $4,500.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $272.04 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Date: 2 \(12 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Date: l Print Name: • o1 t DI( I o t/\J -u✓•-y This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 1800 0609 0705 0701 MECH EQUIP EFF MECHANICAL FINAL PIPE/DUCT INSULATION REFRIGERATION EQUIP ROUGH -IN MECHANICAL a separate permit issued by the City of Tukwila the job site at the time of inspection. CITY OF TUKW1 Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No.I1/44( - ( �! Project No. Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** King Co Assessor's Tax No.: Site Address: 1101 Andover Park West Suite Number: 168 Floor: Tenant Name: Air Wave Express PROPERTY OWNER Name: Cynthia Tang Address: 1101 Andover Park West, Suite 168 City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Taylor Lowery Address: 1221 2nd Ave N Address: 1221 2nd Ave N Phone: (206) 817-9099 Fax: City: Kent State: WA Zip: 98032 Phone: (206) 817-9099 Fax: Email: taylor.lowery@hermanson.com New Tenant: ❑ Yes „No MECHANICAL CONTRACTOR INFORMATION Company Name: Hermanson Company Address: 1221 2nd Ave N City: Kent State: WA Zip: 98032 Phone: (206) 817-9099 Fax: Contr Reg No.: HERMACLOO5BJ Exp Date: 10/28/2018 Tukwila Business License No.: BUS -0994464 Valuation of project (contractor's bid price): $ 4,500 Describe the scope of work in detail: We will be disconnecting an existing boiler and replacing it with a newer more efficient condensing unit. This will require disconnect of the electrical and gas and then reconnect. Use: Residential: New ❑ Commercial: New Replacement Replacement Fuel Type: Electric ❑ Gas ❑ Other: H: Applications Forms -Applications On Line 2011 Applications Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu 1 Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit 1 >10,000 cftn Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper 1 Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 1 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED A T: Signature: Date: 01/19/2018 Print Name: Taylor Lowery Day Telephone: (206) 817-9099 Mailing Address: 1221 2nd Ave N Kent WA 98032 City State Zip H: Applications Forms -Applications On Line 2011 Applications Mechanical Permit Application Revised 8-9-1 1 .docx Revised: August 201 I bh Page 2 of 2 DESCRIPTIONS PermitTRAK Cash Register Receipt City of Tukwila ACCOUNT QUANTITY PAID EL18-0069 Credit Card F dress._ 1101 ANDOVER PAF MMPI $2.64 Credit Card Fee R000.369.908.00.00 0.00 $2.64 ELECTRICAL $83.86 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $83.86 TECHNOLOGY FEE $4.19;, TECHNOLOGY FEE M18-0011; dress. 101 Credit Card Fee R000.322.900.04.00 NDOVERPARKWCOMPLEXW''!Apn:883650011 0.00 $4.19 $7.92 Credit Card Fee R000.369.908.00.00 0.00 $7.92 MECHANICAL $i PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $170.02 PLAN CHECK FEE R000.322.102.00.00 0.00 $50.79 TECHNOLOGY FEE $10.16 TECHNOLOGY FEE R000.322.900.04.00 0.00 $10.16 PG18-0006 Address: • ANDOVER' OMPLE 65 0r Credit Card Fee $3.13 Credit Card Fee R000.369.908.00.00 0.00 $3.13 GAS $99.45 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $66.30 TECHNOLOGY FEE 4.97' TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R13482 R000.322.900.04.00 0.00 $4.97 $470.28 Date Paid: Friday, January 19, 2018 Paid By: SYDNEY LOWERY Pay Method: CREDIT CARD 477491 Printed: Friday, January 19, 2018 10:45 AM 1 of 1 I?SYSTEMS 6/1/2018 City of Tukwila Department of Community Development TAYLOR LOWERY 1221 SECOND AVE N KENT, WA 98032 RE: Permit No. M18-0011 AIR WAVE EXPRESS 1101 ANDOVER PARK W Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 7/25/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or fmal inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 7/25/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Rac el ate pley P1119 Permit Technician File No: M18-0011 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0011 DATE: 01/19/18 PROJECT NAME: AIR WAVE EXPRESS SITE ADDRESS: 1101 ANDOVER PARK W X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: A5�L J,l3-te Building Division Public Works API )9- 1 -2z -r6 Fire Prevention Structural Planning Division ❑ Permit Coordinator • PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 01/23/18 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required DUE DATE: 02/20/18 ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping 0 PW 0 Staff Initials: 12/18/2013 HERMANSON COMPANY LLP Horne Espanol Contact Search L&� Page 1 of 3 A -Z index lfell) My i &1 Safety & Health Claims & Insurance Workplace Rights Washington State Department of Labor & Industries HERMANSON COMPANY LLP Owner or tradesperson Principals NICOLAISEN, KNUT H, PARTNER/MEMBER BROCK, DANIEL L, PARTNER/MEMBER FOX, DEAN M, PARTNER/MEMBER HENGEL, STEPHEN A, PARTNER/MEMBER DYCKMAN, KENNETH A, PARTNER/MEMBER ROBINETT, PAUL J, PARTNER/MEMBER HERMANSON, RICHARD L, PARTNER/MEMBER ALMON, KEVIN, PARTNER/MEMBER (End: 08/05/2010) MACDONALD, JAMES, PARTNER/MEMBER (End: 08/05/2010) Doing business as HERMANSON COMPANY LLP WA UBI No 602 004 844 1221 2ND AVE N KENT, WA 98032-2945 206-575.9700 KING County Business type Limited Liability Partnership Governing persons CORP HERMANSON LLC HERMANSON GROUP; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. HERMACLOO5BJ Effective — expiration 01/11/2000— 08/25/2018 Bond WESTERN SURETY CO Bond account no. 929381801 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 12/01/2005 01/01/2006 Expiration date Until Canceled Trades & Licensing Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602004844&LIC=HERMACL005BJ&SAW= 1/26/2018 HERMANSON COMPANY LLP 1"\ Insurance ..................... Valley Forge Ins Co $1,000,000.00 Policy no. 6043050846 Received by L&I Effective date 08/18/2017 08/21/2017 Expiration date 08/21/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&1 Tax debts ......._..._ ....................... No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 409.648-01 Account Is current. Doing business as HERMANSON COMPANY LLP Estimated workers reported Quarter 3 of Year 2017 "Greater than 100 Workers" L&I account contact T4 / NIKKI BUTLER (360)902-4918 - Email: BUTQ235@lni.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 02/23/2016 Inspection no. 317939295 Location 15580 NE 31st St. Redmond, WA 98052 Inspection results date 05/21/2015 Inspection no. 317935231 Location 4480 154th PI NE Redmond, WA 98052 Inspection results date 12/10/2014 Inspection no. 317424935 No violations No violations No violations Page 2 of 3 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602004844&LIC=HERMACL005BJ&SAW= 1/26/2018 A AC ACH ACT AD ADD'L AFF AFG AHU ALUM AMP/AMPS AP ARCH BC BDD BF BHP BLDG BOD BOP BOT BS BTU BTUH CAP CBD CC CD CDWR CDWS CFM CHWR CHWS CLG COL CONC COND CONN CONT CONTR COORD COP CT CU CW DB DDC DEFL DEG DIA DMPR DN DOAS DWG EXH EA EAT EC EER EF EFF EL ELEC/ELECT EMCS ENT EQUIP ESP T EXIST/(E) EXH F FAC FD FDC FF FIC FIO FLA FLEX FLR FOB FOIC FOS FOT FP FPM FSD FT FUT FV G GA GALV GC GPM GRD GWB HD HORIZ HP HR HSPF HT HWTG HWR HWS HX HZ MECHANICAL ABBREVIATIONS AMPS AIR CONDITIONING AIR CHANGES PER HOUR ACOUSTICAL CEILING TILE ACCESS DOOR ADDITIONAL ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AIR HANDLING UNIT ALUMINUM AMPERAGE ACCESS PANEL ARCHITECT BEADED COLLAR BACKDRAFT DAMPER BELOW FLOOR BRAKE HORSEPOWER BUILDING BOTTOM OF DUCT BOTTOM OF PIPE BOTTOM BIRD SCREEN / BLACK STEEL BRITISH THERMAL UNIT BRITISH THERMAL UNITS PER HOUR CAPACITY CALIBRATED BALANCING DAMPER CONTROLS CONTRACTOR CEILING DIFFUSER/CONDENSATE DRAIN CONDENSER WATER RETURN CONDENSER WATER SUPPLY CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY CEILING COLUMN CONCRETE CONDENSATE CONNECT/CONNECTED/CONNECTION CONTINUOUS/CONTINUATION CONTRACTOR COORDINATE COEFFICIENT OF PERFORMANCE COOLING TOWER CUBIC/CONDENSER UNIT DOMESTIC COLD WATER/CONDENSER WATER DUCTBOARD/DRY BULB/DECIBEL DIRECT DIGITAL CONTROL DEFLECTION DEGREE/DEGREES DIAMETER DAMPER DOWN DEDICATED OUTSIDE AIR SYSTEM DRAWING EXHAUST EACH ENTERING AIR TEMPERATURE EGGCRATE GRILLE/END CAP/ELEC CONTRACTOR ENERGY EFFICIENT RATING EXHAUST FAN EFFICIENCY ELEVATION ELECTRICAL/ELECTRIC ENERGY MANAGEMENT CONTROL SYSTEM ENTERING EQUIPMENT EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXISTING EXHAUST FAHRENHEIT FIRE ALARM CONTRACTOR FIRE DAMPER FIRE DEPARTMENT CONNECTION FINISHED FLOOR FURNISHED AND INSTALLED BY CONTRACTOR FURNISHED AND INSTALLED BY OWNER FULL LOAD AMPS FLEXIBLE FLOOR FLAT ON BOTTOM FURNISHED BY OTHERS, INSTALLED BY CONTRACTOR FLAT ON SIDE FLAT ON TOP FIRE PROTECTION FEET PER MINUTE FIRE/SMOKE DAMPER FOOT/FEET FUTURE FACE VELOCITY GRILLE GAUGE/GALLON GALVANIZED GENERAL CONTRACTOR GALLONS PER MINUTE GRILLE/REGISTER/DIFFUSER GYPSUM WALL BOARD HEAD HORIZONTAL HORSEPOWER HOUR HEATING SEASONAL PERFORMANCE FACTOR HEIGHT HIGH WALL TRANSFER GRILLE HOT WATER RETURN HOT WATER SUPPLY HEAT EXCHANGER HERTZ BC NTERNATIONAL BUILDING CODE CW NDUSTRIAL COLD WATER D NSIDE DIAMETER/DIMENSION E NVERT ELEVATION EER NTEGRATED ENERGY EFFICIENCY RATIO MC NTERNATIONAL MECHANICAL CODE N NCHES N WG NCHES WATER GAUGE PLV NTEGRATED PART LOAD VALUE KW KILOWATTS LAT LEAVING AIR TEMPERATURE LB/LBS POUND/POUNDS LF/LIN FT LINEAL FOOT/FEET LPG LIQUID PROPANE GAS LPS LOW PRESSURE STEAM LVG LEAVING LWA LWG LWT MAX MAU MBH MCA MD MFR MISC MIN MPS MT SOUND POWER RATING LEVEL (IN DB) LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM MAKE UP AIR UNIT 1000 BRITISH THERMAL UNITS/HOUR MINIMUM CIRCUIT AMPACITY MOTORIZED DAMPER MANUFACTURER MISCELLANEOUS MINIMUM/MINUTE MEDIUM PRESSURE STEAM MOUNT MTD MOUNTED MUW MAKE-UP WATER NA NOT APPLICABLE NC NORMALLY CLOSED/NOISE CRITERIA NG/NGAS NATURAL GAS NIC NOT IN CONTRACT NO NORMALLY OPEN/NUMBER NPW NON -POTABLE WATER N -R NON-RESIDENTIAL OA/OSA OUTSIDE AIR OBD OPPOSED BLADE DAMPER OD OUTSIDE DIAMETER/DIMENSION PCF POUNDS PER CUBIC FOOT PD PRESSURE DROP PH PHASE POC POINT OF CONNECTION P/PRESS PRESSURE PSI POUNDS PER SQUARE INCH PSIG POUNDS PER SQUARE INCH GAUGE QTY QUANTITY R RETURN GRILLE/RELOCATED/RETURN RA RETURN AIR RD/RND ROUND REF REFERENCE REQ REQUIRED RESID RESIDENTIAL RF RELIEF RG REFRIGERANT DISCHARGE GAS RL REFRIGERANT LIQUID RPM REVOLUTIONS PER MINUTE RS REFRIGERANT SUCTION S SUPPLY SA SUPPLY AIR SAT SATURATION/SUPPLY AIR TEMPERATURE SD SMOKE DETECTOR S/D SLIP & DRIVE CONNECTION S_C SEATTLE CODE SEER SEASONAL ENERGY EFFICIENCY RATING SENS SENSIBLE SL SOUND LINED SM SHEETMETAL SPEC SPECIFICATION SO SCREENED OPENING SOG SLAB ON GRADE SP STATIC PRESSURE SF SQUARE FEET SS STAINLESS STEEL STRUC STRUCTURAL TA TRANSFER AIR TEMP TEMPERATURE/TEMPORARY TBD TO BE DETERMINED TOD TOP OF DUCT TOS TOP OF STEEL/TOP OF SLAB TOT TOTAL TSP TOTAL STATIC PRESSURE TSTAT THERMOSTAT TYP TYPICAL UH UNIT HEATER UNO UNLESS NOTED OTHERWISE V VOLT VD VOLUME DAMPER VEL VELOCITY VERT VERTICAL VFD VARIABLE FREQUENCY DRIVE VOL VOLUME W WRAPPED DUCT WB WET BULB WG WATER GAUGE W/ WITH W/0 WITHOUT W/SF WATTS PER SQUARE FOOT WSEC WASHINGTON STATE ENERGY CODE MECHANICAL LEGEND 0"X10"� ,10"X10"�� -10"X10";) 11011X10" 0"X10"Vl 10"X10"121 -10"X 10";,' ,10"X 10"a 10"0(d S 10"o' 10"O Q 12"X10°0 S 12"X1O"O I') (s) RECT SUPPLY AIR DUCT UP/TOWARD RECT SUPPLY AIR DUCT DN/AWAY RECT EXHAUST OR RETURN DUCT UP/TOWARD RECT EXHAUST OR RETURN DUCT DN/AWAY ROUND DUCT - UP/TOWARD ROUND DUCT - DN/ AWAY FLATOVAL DUCT - UP/ TOWARD FLATOVAL DUCT - DN/ AWAY DUCT OVERLAP BOOT TAP 45' TAP VOLUME DAMPER CALIBRATED BALANCING DAMPER RISE(R) & DROP(D) TRANSITION TURNING VANES/SPLITTERS DUCT MOUNTED SMOKE DETECTOR BACK DRAFT DAMPER FLEXIBLE DUCT AIR FLOW (FORCED AIR) f X16_OQSL{ Li aL " ##X##"o ##1 CD1-100 COMBINATION FSD FIRE DAMPER SMOKE DAMPER MOTOR OPERATED DAMPER ACCESS DOORS SOUND TRAP FLEX CONNECTION ACOUSTICALLY LINED DUCT OD = OUTSIDE DIMENSIONS SL = SOUND LINING (THICKNESS) FABRIC DUCT CLEARANCE SUPPLY AIR DIFFUSER (WITH CORE BLANKOFF/ROTATE) CEILING RETURN, TRANSFER OR EXHAUST AIR GRILLE SLOTTED DIFFUSER (PLAN VIEW) REVISION CLOUD & TRIANGLE ROUND DUCT SYMBOL FLATOVAL DUCT SYMBOL DEGREES SYMBOL POINT OF CONNECTION GRD TAG IDENTIFIER = TYPE -CFM 8"0 SIZE T T'STAT/TEMP SENSOR ®o CARBON DIOXIDE H HUMIDITY SENSOR SENSOR 0 SMOKE DETECTOR 0 CARBON MONOXIDE sP STATIC PRESSURE SENSOR SENSOR O° OCCUPANCY SENSOR SO SENSOR 0 � z 2-CHWS /CHWR-5 2-- RL/RS-5 r--NG-5 2-- LPG -5 2-CDWS /CDWR-5 z-HWS/HWR-s z- COND -5 FOV --s 2- FOS / FOR -5 2-- RDG --s EXISTING DUCTWORK DEMO DUCTWORK WALL -MOUNTED GRILLE PIPE ELBOW UP PIPE ELBOW DN DIRECTION OF FLOW DIRECTION OF SLOPE DOWN PLUG OR CAP PRESS REDUCING ASSEMBLY SOLENOID VALVE PUMP CHILLED WATER SUPPLY/RETURN REFRIGERANT LIQUID/SUCTION NATURAL GAS LIQUID PROPANE GAS CONDENSER WATER SUPPLY/RETURN HEATING WATER SUPPLY/RETURN CONDENSATE FUEL OIL VENT FUEL OIL SUPPLY/RETURN REFRIGERANT DISCHARGE GAS MECHANICAL GENERAL NOTES 1. WORK SHALL CONFORM TO APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE 2015 IBC, 2015 WSEC, 2015 IMC, & & SIMILAR YEAR WAC 296-104 BOILER RULES. 2. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UNO. 3. LOCATION AND DETAILS OF EQUIPMENT, DUCT ROUTING, AND CONNECTIONS ARE APPROXIMATE. COORDINATE FINAL LOCATIONS WITH OTHER TRADES. INSTALL IN ACCORDANCE WITH APPROVED SUBMITTALS AND DETAIL DRAWINGS WHEN APPLICABLE. 4. VERIFY EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH WORK. 5 AS EFOR CONSTRUCTION CSIM LAR DETAILS ARE ADDITIONALV QUESTIONS REMAIN, CONTACT OTHE HENGINEER PRIORSTOHPROCEEDING. SAME 6. ALL STRUCTURAL OPENINGS AND PLATFORMS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR UNO. 7. DUCT SEALING AND CONSTRUCTION TO MEET SMACNA AND ENERGY CODE REQUIREMENTS. UNLESS OTHERWISE NOTED, LOW PRESSURE DUCTWORK DOWNSTREAM OF VAV BOXES, CONSTANT VOLUME AC SYSTEMS, TOILET EXHAUSTS, ETC.) TO MEET 2" CONSTRUCTION STANDARDS WITH SEAL CLASS C. MEDIUM PRESSURE DUCTWORK (UPSTREAM OF VAV BOXES, HIGH VELOCITY EXHAUSTS, ETC) TO MEET 4" CONSTRUCTION STANDARDS WITH SEAL CLASS A. DUCT RISERS IN SHAFTS WITH DAMPERED PENETRATIONS TO MEET 6" CONSTRUCTION STANDARDS WITH SEAL CLASS A. 8. ALL CEILING DIFFUSERS ARE 4 -WAY THROW UNLESS NOTED OTHERWISE. 9. ALL DUCT DIMENSIONS ARE OUTSIDE DIMENSIONS BEFORE SOUND LINING HAS BEEN ACCOUNTED FOR (SOUND LINING ® 1", UNO) 10. OUTSIDE AIR INTAKES ON ALL AIR HANDLING UNITS SHALL BE 10 FEET AWAY FROM ANY VENTS, STREETS, LOADING DOCK, NEIGHBORING LOT LINES & FUEL BURNING EQUIPMENT OR 3 FEET BELOW OR 25' ABOVE ANY CONTAMINANT SOURCE WITHIN 10 FEET. 1. ALL AIR ECONOMIZERS SHALL BE CAPABLE OF THE FOLLOWING PER C403.3.1 & C403.2.4.7: - 0% TO 100% OF THE DESIGN SUPPLY AIR WITH FAULT DETECTION & DIAGNOSTIC REPORTING. -CONTROLLED BY A CONTROL SYSTEM DETERMINING IF THE OUTSIDE AIR CAN MEET PART OR ALL OF THE BUILDING COOLING LOADS. - INTEGRATED TO PROVIDE PARTIAL COOLING EVEN WHEN MECHANICAL COOLING IS REQUIRED. 2. OUTSIDE AIR INTAKE, RELIEF, AND EXHAUST OPENINGS SHALL BE EQUIPPED WITH MOTORIZED CLASS 1 LOW LEAK (<4 CFM/SF © 1" WG) DAMPERS (OR GRAVITY PER EXCEPTIONS IN C403.2.4.3) DAMPERS WHICH CLOSE AUTOMATICALLY WHEN SYSTEM IS OFF OR UPON POWER FAILURE, UNO FOR SMOKE CONTROL SYSTEM OPERATION. 13. THE CONTROL SYSTEM SHALL MEET C403 AND BE PROGRAMMABLE, CAPABLE OF BEING SET FOR DIFFERENT DAY TYPES PER WEEK, DEADBAND SETTING OF AT LEAST 5'F (10'F FOR RESIDENTIAL), BETWEEN THE HEATING AND COOLING SETPOINTS AND SETBACK TEMPERATURES WITH OPTIMAL START CONTROL. CONTROL SYSTEM SHALL INCLUDE A MICROPROCESSOR AND BE CAPABLE OF VARYING FLOWS AND RESETTING SUPPLY AIR & WATER TEMPERATURES BY REPRESENTATIVE BUILDING LOADS WHERE REQUIRED IN C403.4. 14. WHERE REQUIRED BY C408 RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER THE ENERGY CODE. AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER. ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCING REPORT SHALL BE PROVIDED TO THE OWNER. HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE WITH APPROVED PLANS. A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY. A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PROVIDED TO THE OWNER. 15. MECHANICAL SYSTEMS SHALL COMPLY WITH SEISMIC RESTRAINT REQUIREMENTS OF THE BUILDING CODE SMACNA AND ASCE 7. ALL LIFE SAFETY OR HAZARDOUS MATERIAL RELATED SYSTEMS SHALL BE DEEMED AN Ip=1.5 FOR RESTRAINT METHODS OR AS NOTED ON THE DRAWINGS. REFER TO CODES FOR INSTALLATION REQUIREMENTS AND EXCEPTIONS BASED ON SIZING, WEIGHTS AND MOUNTING HEIGHTS. 16. PROVIDE EARTHQUAKE RESTRAINTS FOR HVAC EQUIPMENT AS REQUIRED BY SMACNA SEISMIC RESTRAINT MANUAL, SEISMIC HAZARD B. WIRES FOR CEILING SYSTEM ETC. SHALL NOT BE HUNG OFF HVAC EQUIPMENT OR HVAC EQUIPMENT SUPPORTS. 17. PROVIDE FIRE AND COMBINATION FIRE/SMOKE DAMPERS WHERE SHOWN ON PLANS AND WHERE REQUIRED PER CODE. 18. ALL PIPING PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE SEALED WITH AN UL APPROVED FIRE CAULKING. 19. SMOKE DETECTORS PROVIDING AUTOMATIC SHUTDOWN SHALL BE PROVIDED IN THE RETURN AIR, PER MECH CODE, SUCH AS HVAC EQUIPMENT DELIVERING (NOT EXHAUST) >2000 CFM (INCLUDING MULTIPLE UNITS DUCTED INTO COMMON DISTRIBUTION OR RETURN, WITH A TOTAL SUPPLY >2000 CFM) OR EACH STORY OF RETURN SYSTEMS OVER 15,000 CFM IN A MULTI -STORY INSTALLATION, NOT IN SYSTEMS SERVING SINGLE ROOMS SPACES. SMOKE DETECTORS SHALL BE FIC (ELEC) UNO. POWER -WIRING AND INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR AS APPLICABLE. VAV BOX (WITH FAN) SHUTDOWN CAN BE THROUGH CONTROLS SYSTEM. 20. MECHANICAL ACCESS PANELS SHALL BE PROVIDED BY MECHANICAL CONTRACTOR AND INSTALLED BY GENERAL CONTRACTOR. 21. ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. MOTOR EFFICIENCIES TO MEET OR EXCEED CODE MINIMUM. 22. FOR ALL "SEALED AIR TIGHT" OR PRESSURIZED SHAFTS/ROOMS, THE FOLLOWING SHALL OCCUR: -ALL VERTICAL JOINTS & CORNERS SHALL BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT (BY GC). -TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC). -ANY FLOOR DECKING PERPENDICULAR TO THE CONSTRUCTION SHALL BE CAULKED (BY GC). FILLING WITH ROCK WOOL IS NOT ACCEPTABLE. - ANY PENETRATIONS OF THE CONSTRUCTION (DUCTWORK CONDUIT PIPING ...) SHALL BE SEALED ON BOTH SIDES - ALL DOORS SHALL BE PROVIDED WITH TIGHT FITTING GASKETS AND THRESHOLD SWEEPS, AND OPEN AGAINST THE DIRECTION OF PRESSURE. - USE SECTION 909.5 OF THE 2012 IBC FOR MAX ALLOWABLE LEAKAGE AREA, FOLLOWING THE GUIDELINES FOR TIGHT STAIR SHAFT CONSTRUCTION. 23. ALL ADHESIVES, SEALANTS, PAINTS AND COATINGS USED DURING THE INSTALLATION/FINISH WORK SHALL MEET THE LEED REQUIREMENTS FOR IEQ. 24. MAXIMUM STANDARD LENGTH OF FLEXIBLE DUCT SHALL BE 12 FEET; UP TO 25' MAXIMUM LENGTH IS ACCEPTABLE IF; FLEX DUCT (UL -181 TESTED & NOT "CONNECTOR") IS USED DUCT 0 IS INCREASED BY 1 NOMINAL SIZE & BENDS DO NOT EXCEED 235' TOTAL. REFER TO INSTALLATION DETAILS FOR SUPPORT REQUIREMENT'S. FLEXIBLE DUCT FLAME SPREAD RATING SHALL BE < 25 AND SMOKE DEVELOPED RATING SHALL BE < 50. USE THERMAFLEX MODEL G -KM FOR LOW AND MEDIUM PRESSURE APPLICATIONS OR APPROVED EQUAL. 25. ELECTRICAL METERING OF SYSTEMS AS REQUIRED BY ENERGY CODE SECTION C409 IS BY ELECTRICAL. THE ELECTRICAL DESIGN & CONTRACTOR TEAM WILL FURNISH THE NECESSARY ELECTRICAL DISTRIBUTION AND METERING COMPONENTS - SEE ELECTRICAL DRAWINGS. THE MECHANICAL CONTRACTOR WILL FURNISH A BUILDING MANAGEMENT SYSTEM CAPABLE OF COLLECTING AND STORING THE INFORMATION WITH A VISIBLE DISPLAY/NOTIFICATION READILY ACCESSIBLE TO OPERATION AND MANAGEMENT PERSONNEL AS REQUIRED. 26. C406 "ADDITIONAL ENERGY PACKAGE OPTIONS" AS APPLICABLE. DRAWING INDEX SHEET NO. SHEET TITLE CURRENT REVISION REMARKS SUPPLY & RETURN M0.00 LEGEND, ABBREVIATIONS, GENERAL NOTES, & SHEET INDEX - HVAC 1,2,3 M0.01 SCHEDULE SHEET - HVAC SEE NOTES 4 & 5 M2.R1 PARTIAL ROOF PLANS - HVAC NOT WITHIN CONDITIONED SPACE: INSIDE BUILDING R-6 1,2 SUPPLY AIR <55° OR >105° 1 1:1=D Tr rd/12 ') WITHIN CONDITIONED SPACE O Cf1n CI InTuen nerll Irnrwwrnrre, el w1 nr. r. - ___ _ R-3.3 1,2 0.29-0.32 200 3.0 APN NUMBER 8836500110 LEGAL DESCRIPTION UPLANDS TUKWILA INDUSTRIAL PARK POR SW 1/4 OF SE 1/4 OF SEC 26-23-4 DESC AS FOLG - BAAP ON E LN OF PARCEL TO UNION PACIFIC LAND RESOURCES CORP BY QCD DATED 4-1-1971 UPLRC AUDIT NO 494 FR WCH PT THE SE COR SD PARCEL BEARS S 01-47-29 W 188 FT TH N 88-04-00 W 307.46 FT TO BEG OF NON -TANGENT CURVE TO RGT RAD LN WCH BEARS S 65-57-33 W 359.26 FT TH SLY ALG SD CURVE THRU C/A 11-17-14 ARC DIST 70.77 FT TO BEG OF COMPOUND CURVE TO RGT RAD 408.34 FT TH SLY ALG SD CURVE THRU C/A 13-21-17 ARC DIST 95.18 FT TH S 87-55-02 E 229.87 FT TO BEG OF TANGENT CURVE TO LFT RAD 40 FT TH NELY ALG SD CURVE THRU C/A 90-17-29 ARC DIST 63.04 FT TAP ON W LN ANDOVER PARK W 60 FT WIDE AS NOW EST TH N 01-47-29 E 120.79 FT TO POB Hermanson Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg II: HERMACLOO5BJ AIR WAVE BOILER REPLACEMENT 1101 ANDOVER PARK WEST, SUITE 168 TUKWILA, WA 98188 I SEPA `ClATE PERM ;._ EQJIRED FOR: ❑ Mechanical Iiectical �i bin as Piping-,,: Ci,,, of Tukwila I.S.IILD!NIG DIVISION REVIEWED FOR CODE COMPLIANCE PP VFD folLPIMULJNI DUCT INSULATION LAST UPDATED 07/11/16 DUCT TYPE DUCT LOCATION (IN HEATED AND MECHANICALLY COOLED DUCT SYSTEM) INSULATION R -VALUE REMARKS SUPPLY & RETURN NOT WITHIN CONDITIONED SPACE: OUTSIDE BUILDING R-8 1,2,3 OUTSIDE AIR WITHIN CONDITIONED SPACE: INSIDE BUILDING SEE NOTES 4 & 5 1,2,3,4,5 SUPPLY & RETURN NOT WITHIN CONDITIONED SPACE: INSIDE BUILDING R-6 1,2 SUPPLY AIR <55° OR >105° 1 1:1=D Tr rd/12 ') WITHIN CONDITIONED SPACE O Cf1n CI InTuen nerll Irnrwwrnrre, el w1 nr. r. - ___ _ R-3.3 1,2 - • -- • �1\ . \ 1\L\(V11\LI'ILIY I J lX t L. J R rV:7 rVR RCJIUCIV I1HL 11VJ I HLLH 11VIVJ 2 INSULATED COOLED DUCTS REQUIRED A VAPOR RETARDER (PERM < 0.5) AND SEALED JOINTS 3 WEATHERPROOF BARRIER REQUIRED AROUND DUCTWORK TO MAINTAIN WATER TIGHTNESS 4 INSULATE OUTSIDE AIR DUCTS TO BUILDING EXTERIOR WALL LEVEL PER ENERGY CODE SECTION: C403.2.8.1 UNTIL CONNECTED TO EQUIPMENT SERVED OR TO THE CODE REQUIRED SHUTOFF DAMPER (AND Z11 THICK INSULATION MIN. TO PREVENT CONDENSATION ON DUCTS IN PLENUM UP TO THE HEATING OR COOLING EQUIPMENT) 5 R-7 CAN BE USED IN LIEU OF BUILDING ENVELOPE INSULATION LEVEL IF: DEDICATED OUTSIDE AIR SYSTEM AND <2 E INSULATION LAST UPDATED: 07/11/16 FLUID DESIGN OPERATING TEMP °F INSULATION CONDUCTIVITY NOMINAL PIPE DIAMETER (INCH) CONDUCTIVITY RANGE MEAN TEMP RATING °F <1 1 TO <1-1/2 1-1/2 TO <4 4 TO <8 >8 HEATING SYSTEMS (STEAM, CONDENSATE, HYDRONIC HOT WATER, DOMESTIC HOT WATER & RECIRC) >350 0.32-0.34 250 4.5 5.0 5.0 5.0 5.0 251-350 0.29-0.32 200 3.0 4.0 4.5 4.5 4.5 201-250 0.27-0.30 150 2.5 2.5 2.5 3.0 3.0 141-200 0.25-0.29 125 1.5 1.5 2.0 2.0 2.0 105-140 0.21-0.28 100 1.0 1.0 1.5 1.5 1.5 DOMESTIC COLD WATER AND HORIZONTAL RAIN LEADERS TO FIRST VERTICAL RAIN LEADER (TO PREVENT CONDENSATION) N/A 0.21-0.27 75 0.5 I 0.5 J 0.5 0.5 0.5 COOLING SYSTEMS (CHILLED WATER, BRINE AND REFRIGERANT, WATERSIDE ECONOMIZER SYSTEMS)** 40-60 0.21-0.27 75 0.5 0.5 1.0 1.0 1.0 <40 m ^-,- . 0.20-0.26 75 0.5 1.0 1.0 1.0 1.5 NOT REQUIRED FOR STRAINERS, CONTROL VALVES & BALANCING VALVES ASSOCIATED WITH PIPING 111 OR LESS IN DIA. TYPICAL CONDENSER WATER PIPE IN NON -ECONOMIZER SYSTEMS IS NOT INSULATED SEE R403 FOR RESIDENTIAL INSTALLATIONS. 9 °• p.� iky�cff Tulzvvilr 4.A l 6J 13'ad. a.. • Id VICINITY MAP Qy NO SCALE SITE MAP FILE COPY NO SCALE Permit Nos M1- 0© I I Plan review a 3proval is subject to errors and omissions. Approval of c Jnstruction documents does not authorize the violation c f any adopted code or ordinance. Receipt of approved F eld Copy and conditions is acknowledged: Date: / 1c‘ City of Tukwila BUILDING DIVISION REVISIONS No changes shs'•t ho rmr de to the scope of work withc :L prio • approval of r>.;iRc_l ing Division. will require a new plan submittal 1 may i i is ude additional plan review fees. RECEIVED CITY OF TUKWILA JAN 19 2010 PERMIT CENTER t1I800iI ISSUE FOR PERMIT Revisions 01/19/18 MG ISSUE FOR PERMIT No. Date By Description Design Design Team MG Drawn FVP Checked DTN Pre -Construction Number 14-18-09780 Construction Number Issue Date 01/19/18 LEGEND, ABBREVIATION, GENERAL NOTES & SHEET INDEX - HVAC M0.00 GAS FIRED WATER HEATING BOILER SCHEDULE DE 0 UNIT LAST UPDATED: 1/10/2018 UNIT TAG LOCATION SERVES BASIS OF DESIGN INPUT MBH OUTPUT MBH NG CONN RECOVERY GPM ELECTRICAL FLUE OPERATING WEIGHT Lbs REMARKS 60F RISE 100F RISE AMPS V/PH SIZE MATERIAL B-1 ROOF DOMESTIC HW SYSTEM AJAX WNG-350-W 350 280 1" 560 336 12 120/1 B-1 B -VENT 1,025 1 KtlVIHKK5 1 DEMO EXISTING UNIT HI -EFFICIENCY - REPLACEMENT UNIT LAST UPDATED:. 1/16/2018. UNIT TAG LOCATION', SERVES BASIS OF DESIGN INPUT MBH OUTPUT MBH AFUE TURNDOWN NG CONN PERFORMANCE ELECTRICAL FLUE OPERATING WEIGHT Lbs REMARKS. TEMP RISE / GPM FLOW AMPS V/PH SIZE MATERIAL B-1 ROOF DOMESTIC HW SYSTEM LAARS NOETHERM-285 285 264 95 5:1 3/4" 20F / 27GPM 40F / 13GPM 7.4 120/1 4" PVC / CPUC 321 1-7 GENERAL: ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS (ELECTRICAL, WEIGHT, SIZE, ETC...) WITH APPROVED SUBMITTALS P REMARKS: 1 2 3 4 5 6 7 OR TO INSTALLATION; FIELD COORDINATE FINAL LOCATION & INSTALL PER MANUFACTURERS REQUIREMENTS REPLACEMENT BOILER TO BE INSTALLED AT THE SAME LOCATION AS OLD BOILER WEIGHT OF NEW BOILER IS LESS THAT WEIGHT OF BOILER BEING REPLACED, NO STRUCTURAL CALCULATION IS REQUIRED PER TUKWILA BUILDING DEPARTMENT. REUSE EXISTING ELECTRICAL WIRING AND -DISCONNECT, MODIFY OR REPLACE AS NEEDED BY ELECTRICAL CONTRACTOR REUSE EXISTING: GAS PIPING, GAS PRESSURE REGULATOR, MAKEUP WATER, BACKFLOW PREVENTER, EXPANSION TANK, STORAGE TANK - REPLACE OR ADJUST AS NEEDED PROVIDE CONDENSATE NEUTRALIZER AND ROUTE CONDENSATE TO CLOSEST INDIRECT DRAIN REPLACEMENT BOILER TO INCLUDE: CIRCULATOR PUMP, SS BURNER & HEAT EXCHANGER, SPARK IGNITION, 160 PSI MAX PRESSURE, 75PSI PRV, TEMP AND PRESS GAUGE, MANUAL RESET HI' LIMIT, AXIOM MODEL NC -1 CONDENSATE NEUTRALIZER KIT REPLACEMENT BOILER MEETS THE REQUIREMENT OF TABLE C503.4 AND IS 8% HIGHER EFFICIENCY THAN VALUES IN TABLE C403.2.3(5) REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 4 2010 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 19 2018 PERMIT CENTER ISSUE FO;RE IT Il Hermanson Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg II: HERMACLOO5BJ AIR WAVE BOILER REPLACEMENT 1101 ANDOVER PARK WEST, SUITE 168 TUKWILA, WA 98188 Revisions 01/19/18 MG ISSUE FOR PERMIT No. Date By Description Design Design Team MG Drawn FVP Checked DTN Pre—Construction Number 14-18-09780 Construction Number Issue Date 01/19/18 SCHEDULE SHEET - HVAC M0.01 0 a 0 A j PARTIAL ROOF DEMO PLAN - HVAC SCALE: 1/8" = 1'-0" EXIST SLEEPER EXIST GAS DEMO EXISTING BOILER EXIST HWS/R rBLDG HATCH EXISTING EXPANSION TANK AHU (EXISTING) *14 EXIST SLEEPER EXIST GAS REPLACEMENT BOILER TO BE MOUNTED IN THE SAME LOCATION ON EXIST SLEEPERS. RECONNECT TO EXIST HWS, HWR & GAS — MELD ADJUST AS NEEDED. RECONNECT TO EXIST ELECTRICAL, REPLACE OR ADJUST AS NEEDED — BY ELECTRICAL CONTR. SEE BOILER SCHEDULE FOR EQUIPMENT DETAILS r EXIST HWS/R BLDG HATCH EXISTING EXPANSION TANK AHU J (EXISTING) 000 { PARTIAL ROOF PLAN - HVAC SCALE: 1/8" = 1'-0" SCALE: r=1' REVIEWED FOR 'CODE COMPLIANCE APPROVED JAN 2 4 2018 City of Tukwila BUILDILLGEli •(" KEY PLAN SCALE: NONE RECEIVED CITY OF TUKWILA JAN 192018 PERMIT CENTER ISSUE FOR PERMIT Hermanson Building Today, Defining Tomorrow Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg II: HERMACLOO5BJ AIR WAVE BOILER REPLACEMENT 1101 ANDOVER PARK WEST, SUITE 168 TUKWILA, WA 98188 Revisions 01/19/18 MG ISSUE FOR PERMIT No. Date By Description Design Design Team MG Drawn FVP Checked DTN Pre—Construction Number 14-18-09780 Construction Number Issue Date 01/19/18 PARTIAL ROOF PLANS - HVAC M2.R1 LIN/ 0011