Permit M18-0012 - BKM MANAGEMENT - ROOFTOP UNIT REPLACEMENT
BKM MANAGEMENT 981 INDUSTRY DR EXPIRED 9110118 M18-0012 Parcel No: Address: Project Name: 0 City of Tukwila Q Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 2523049034 Permit Number: M18-0012 981 INDUSTRY DR BKM MANAGEMENT Issue Date: 1/31/2018 Permit Expires On: 7/30/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: BKM TUKWILA 117 LLC 111 THEORY STE #250 , IRVINE, WA, 92617 JENNIFER HEMPHILL 329 WELLS AVE S , RENTON, WA, 98057 INTERSTATE CONSTRUCTION LLC 329 WELLS AVE S , RENTON, WA, 98057 INTERCL831RD Phone: (206) 851-8112 Phone: Expiration Date: 12/4/2019 DESCRIPTION OF WORK: REPLACE EXISTING ROOF TOP UNIT WITH SAME Valuation of Work: $2,500.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $245.69 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 k - National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Date: 1-3 1—I Pj I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Date: 1- 3 I -11C This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. I v l l Project No. /001/1, Date Application Accepted: ( Date Application Expires: I (For office only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION c61 Site Address: IMP Tenant Name: V-SY\ ✓v\Q,✓^CA. cat,v'r-e4,l4-- 1 -. w King Co Assessor's Tax No.: Suite Number: 60 Floor: New Tenant: ❑ Yes 2.. No PROPERTY OWNER Name: Name: V.3 vs. (n ---\-\c„:_,,,1/43 \ „ \ (' Address: j 3 \ `-1 _„ ,�� gM` J 01 ,'Yr z" Zip:/aJ State:l . A Zip:e City: 11A .,LA.0, 4 CONTACT PERSON — person receiving all project communication Name: Address: F) -D,01, 1 .'e IIS l�1 (' City: n -Q -Vi Statel t p VVV7� Zip:/aJ Phone D S) /)) ,Fax: D Phone3y—)a3Cn-1Fax: Email: J , 1 A -t ?` c ,) Contr Reg No,;._ L.xp Date: MECHANICAL CONTRACTOR INFORMATION Company Name A, „ �s (j►'4 yr Address: 3a C1 \ „ Aim \s City: k 'tev.i State: - INA ZipC0c7 Phone3y—)a3Cn-1Fax: Contr Reg No,;._ L.xp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ Describe the scope of work in detail: c-,plA e,653 5�6'� r6dF 4p Use: Residential: Commercial: L.A,V . New ❑ Replacement El New ❑ Replacement (� Fuel Type: Electric ❑ Gas Other: H:Wpplications\Forms-Applications On Line12016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit 65 dB(A) <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator - domestic 65 dB(A) Incinerator - comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (lam-lOpm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction - in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review - applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN OR AU • ORIZED AGENT: Signature: Date: 1•-1 b" e 7 4�i i 101-).1 p 3157 t 1" Print � ame: s� i1 1 �►'1DayTelephone: � j �-• Mailing Address: l ��-c S — & 1LC:✓1 . k Q City State Zip H:\Applications \Forms -Applications On Line \2016 Applications\Mechanical Permit Application Revised 1-4.16.docx Revised: January 2016 bh Page 2 of 2 DESCRIPTIONS PermitTRAK Cash Register Receipt City of Tukwila ACCOUNT QUANTITY PAID 5 M18-0012 Address: 981 INDUSTRY DR Apn: 2523049034 $245.69 Credit Card Fee $7.16 Credit Card Fee R000.369.908.00.00 0.00 $7.16 MECHANICAL $229.36 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $150.34 PLAN CHECK FEE R000.322.102.00.00 0.00 $45.87 TECHNOLOGY FEE $9.17 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R13512 R000.322.900.04.00 0.00 $9.17 $245.69 Date Paid: Monday, January 22, 2018 Paid By: NICHOLAS THORSON Pay Method: CREDIT CARD 612251 Printed: Monday, January 22, 2018 2:15 PM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: M t_ �� Type off-nC,sp�e�ction: ,, '- / F -Ir AddressBJKrt 131 cV ,i)rivc Datr Called: , SpecialIInstructions Ceirc-l- S sir_ ie Date Wanted: 3-/9-2-0/ .rn� p.m. Requester: \ � ...�.IJ N r Ir--ci✓ Phone No: 2O(o - SS/- g)I z. Approved per applicable codes. Corrections required prior to approval. COMMENTS: /4&k OVA& /kl C.Css,'t Mr,tscq -Pogoe, - (S 1 0-C LS loft�lc c` tre_f,QuIrtd OLce55 2 . A)c_pd tri Sil,( ( i`rCna Inspector: Ca.t.t._ Date: 3z6/5( REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 8/1/2018 City of Tukwila Department of Community Development JENNIFER HEMPHILL 329 WELLS AVE S RENTON, WA 98057 RE: Permit No. M18-0012 BKM MANAGEMENT 981 INDUSTRY DR Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 9/10/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 9/10/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, 4110) Rac e e Rip y Permit Technician File No: M 18-0012 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 a'ERMIT COORD COPY J PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0012 PROJECT NAME: BKM MANAGEMENT SITE ADDRESS: 981 INDUSTRY DR X Original Plan Submittal Response to Correction Letter # DATE: 01/24/18 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: AWL I- -r 6 Building Division Ath Fire Prevention up Planning Division ❑ Public Works ❑ Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 01/25/18 Structural Review Required REVIEWERS INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 02/22/18 Approved ❑ Approved with Conditions Zr Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWERS INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 INTERSTATE CONSTRUCTION L c. Washington State Department of Labor & Industries 0 I lame Espanol Contact !Search L&I Safety & Health Claims & Insurance Page 1 of 2 A -Z llndex Help My L&I Workplace Rights Trades & Licensing INTERSTATE CONSTRUCTION LLC Owner or tradesperson Corprue, Dennis Earl Principals Corprue, Dennis Earl, PARTNER/MEMBER WA UBI No. 604 193 182 329 Wells Ave S RENTON, WA 98057 206-387-2364 KING County Business type Limited Liability Company License Verify the contractors active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. INTERCL831 RD Effective — expiration 12/04/2017-12/04/2019 Bond Platte River Ins Co Bond account no. PR2707126 $12,000.00 Received by L&I Effective date 12/04/2017 11/27/2017 Expiration date Until Canceled Insurance HISCOX INSURANCE COMPANY INC $1,000,000.00 Policy no UDC2111811CGL17 Received by L&I Effective date 12/04/2017 11/20/2017 Expiration date 11/20/2018 Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=604193182&LIC=INTERCL831RD&SAW= 1/31/2018 INTERSTATE CONSTRUCTION J LC No active workers' comp accounts during thesrfous 6 year period. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=604193182&LIC=INTERCL831 RD&SAW= 1/31/2018 SITE VIEW SCALE: 1/64" = V-0" PROJECT SCOPE PROJECT SPECIFIC SCOPE OF WORK REMOVE, DISPOSE OF, & REPLACE EXISTING 3—TON ROOFTOP UNIT WITH NEW TRANE, 3 TON ROOFTOP UNIT. GENERAL NOTES GOVERNING CODES ARE 2015 IBC, 2015 IMC, 2015 IFGC, 2015 UBC, 2015 WASHINGTON STATE ENERGY CODE. -ALL DUCTWORK & SUPPORTS SHALL CONFORM TO THE ' REQUIREMENTS OF THE 2015 IMC. INSULATION OF DUCTS & PIPING SHALL CONFORM TO THE REQUIREMENTS OF THE WASHINGTON STATE ENERGY CODE. ALL MATERIALS INSIDE DUCTS OR PLENUMS SHALL HAVE FLAME SPREAD/SMOKE DEVELOPED RATINGS OF 25/50 OR BETTER. POJECT BATA PROJECT LOCATION PARCEL \UMBER ZO\I\G LOT AREA VICI \ITY VAP SCALE: 1/128" V-0" —0" 981 INDUSTRY DR TUKWILA, WA 98188 CO ALLOWABLE LOT COVERAGE - SETBACKS HEIGHT LIIV IT PAR'<I\G OCCUPA\CY CO\STRUCTION TYPE NUVBER OF STORIES HEIGHT PROJECT AREA 1 V VERCIAL BR -CR REVISIONS 40 (-f F nTi he made to the sem., cif .- p or approval of u'dIng Division. 1"!OTE. 1ev ; wi i roquire a new plan submittal and ', f L ►dude additional plan review tees. * SF OUT OF * SF (TOTAL BUILDING) 1'SEPARATE PERMIT i =:�QU1RED FOR: 0 Mechanical Electrical L Dtumbing (aas Piping City of Tukwila BUILDING DIVISION SHEET I\DEX T-1 TITLE SHEET A-1.1 A-1.2 EXISTING FLOOR PLAN PROPOSED ROOF PLAN M-1.1 R410 TRANE U M-1.2 R410 TRANE U FELE CO Permit Nos Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions Is acknowledged: By: R; e: ci — City of Tukwila BUILDING DIVISION IT SU IT SU B B MITTAL Vl ITTAL REVIEWED 1= O R CODE COMPLIANCE APPROVED JAN 29 MO City of Tukwila DATA (Pg. 1-2) DATA (Pg. 2-2) RECEIVED CITY OF TUKWILA JAN 222018 PERMIT CENTER 329 WELLS AVE. S. RENTON, WA 98057 206.679.3268 SHEET DESCRIPTION TITLE SHEET GENERAL NOTES 01.22.2018 - SCALE AS NOTED No. REVISION/ISSUE DATE STAMPS & CERTIFICATIONS PROJECT NAME & ADDRESS BMK MANAGEMENT COMPANY 981 INDUSTRY DR. TUKWILA, WA 98188 PROJECT No. 2018-0002 SHEET T 1 DATE 01.22.2018 - SCALE AS NOTED A V L.._.. \i I A) , i t �t i' 1-- -, I (�" .:, i{ ALL L 1'1 C I) t: X1 D TIP1!' REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 9 2018 City of Tukwila _Ett=1.I LG fl "-"0 RECEIVED CITY OF TUKWILA JAN 222018 PERMIT CENTER 329 WELLS AVE. S. RENTON, WA 98057 206.679.3268 SHEET DESCRIPTION EXISTI FLOO \G .LA\ GENERAL NOTES r , to 01.22.2018 A 1 1 - . SCALE 1/4" = 1'-0" No. REVISION/ISSUE DATE PROJECT No. SHEET 2018-0002 DATE 01.22.2018 A 1 1 - . SCALE 1/4" = 1'-0" \/ ....__ . A 1.---) 1 A (--, c....-- N 1 -1- c,.....-: 0 A (---„, rc- tA b u /-4,‘....,, L.... \I i ......)1,-._...., L SHEET DESCRIPTION 4-7 -----,- -y-,,------,,"---,,, , ,,,,y.- .. , 1 ,,,--- •-• 4- , SINGLE: NVERTi BLE GAS/RL EC.:IR C SEER 0 # 4YCC 4.0.3 SA 1 070A - R F.: P LAC E EX1STIN C.;'. UNIT - 'i 1 \, n- N EW C 0 4 R41 TO A kic.)--f: El: A L. L HMG IS F. >`,.. 5.3T! N G REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 2018 City of Tukwila LIILDIINACID ("I RECEIVED CITY OF TUKWILA JAN 2 2 2018 PERMIT CENTER 11 329 WELLS AVE. S. RENTON, WA 98057 206.679.3268 PROJECT No. SHEET DESCRIPTION D'OOSED OOF PLA\ GENERAL NOTES DATE A 0 k, la 01.22.2018 SCALE 1/4" = 1'-0" No. REVISION/ISSUE DATE PROJECT No. SHEET 2018-0002 DATE A 1.2 01.22.2018 SCALE 1/4" = 1'-0" Su bmit-ta I le Packaged Convertible Gas/Electric 14 SEER SAFETY SECTION Product Specifications Important -This document contains a w[i]ng diagram, a parts list, and service information. This IS customer property and is to remain with this unit. Please return to service information pack upon completion of work A CAUTION GROUNDING REQUIRED! Failure to inspect or use proper service tools may result in equipment damage or personal injury. Reconnect all devices. All this GENERAL NOTES MODEL 4YCC4036A1070A 4YCC4036A1090A \ / Motor- HP/R.P.M 1/ 5/ 825 1/5/ 825 01.22.2018 RATED Volts/PH/Hz 208-230/1/60 208-230/1/60 SCALE Volts/Ph/Hz 208-230/1/60 208-230/1/60 REVISION/ISSUE DATE Performance Cooling BTUH (a) 37000 37000 F.L. Amps/L.RAmps 1.1 / 2.0 1.1 / 2.0 INDOOR FAN - CONSTANTTORQUE CONSTANTTORQUE Indoor Airflow (CFM) 1190 1190 TYPE ECM ECM A WARNING , <,. HAZARDOUS GASES! Exposure to fuel substances or by-products of incomplete fuel combustion is believed by the state of California to cause cancer, birth defects, or grounding parts of product that are capable of conducting electrical current are grounded. If grounding wires, screws, straps, clips, nuts, or washers used to complete a path to ground are removed for service, they must be returned to their original position and properly fastened. Power Input (KW) 3.08 3.08 Dia. x Width (In.) 10.62 X 10.62 10.62 X 10.62 EER/SEER (BTU/Watt- 12.0/ 14.00 12.0/ 14.00 Drive/No. Speeds DIRECT -3 DIRECT -3 Hr.) SEE FAN PERF SEE FAN PERF Sound Power Rating 69.3 69.3 CFM @ 0.0 (n. w.g. (g) TABLE TABLE [dB(A)] co) Motor- HP/R.P.M. 1/2/ 1050 1/2 / 1050 PERFORMANCE H (�> Volts/Ph/Hz 208-230/1/60 208-230/1/60 other reproductive harm. This warning complies with state of California law,70000 Proposition 65 �,,Y WARNING 1 V (N 1j, w y ,,. � ,,,,, ,,,,,, , ,,, ,�,m., „ ���,�, d1 UNIT CONTAINS R -410A Input BTU BTUH-1st Stage 90000 F.L. Amps 4.1 4.1 (Natural Gas) (d) COMBUSTION FAN CENTRIFUGAL AFUE 81 81 -TYPE CENTRIFUGAL Temp. Rise -Min/Max Drive/No. Speeds DIRECT/ 1 DIRECT/ 1 AWARNING HAZARDOUS VOLTAGE! Failureto followthis Warningcould property damage, severe personal Disconnect all electric power, including disconnects before servicing. lockout/tagout .,, I result inPowERCONN.-V/ injury, or death. remote Follow proper REFRIGERANT!30/60 Failure to use proper may result in equipment damage or personal injury. R -410A operating pressure exceeds the limit of R- 22. Proper service equipment is required. Service using only R -410A Refrigerant and approved POE compressor oil. (°F) 35/65 Motor- HP/R.RM. 1/34 / 3290 1/34 / 3075 Orifice Qty/Drill Sz. (Natural Gas) 2/#33 3/#37 Volts/Ph/Hz 230/1/60 230/1/60Sin FLA 20 .24 Ph/Hz 208-230/1/60 208-230/1/60 FILTER/ NO NO NO Min. Bich. Clr. FURNISHED Ampacity (e) 24.5 24.5 Type Recommended THROWAWAY THROWAWAY 4YCC4036A1070A 4YCC4036A1090A err„ ._--� (1,;! (1 �►11)))));;�1%•_..___ Fuse Size - Max. (amps) 40 40 Recmd. Face Area (sq. ft) (h) 4.0 4.0 procedures to ensure the power cannot be inadvertently energized.i A WARNING E Ix° Fuse Size- Recmd. 40 40 REFRIGERANT R-410 R-410 (amps) Charge (lbs.) 7.2 7.2 � �� � i � k.' ,A WARN I NG ti SAFETYAND ELECTRICAL HAZARD! Failure to follow this Warning could result in property damage, severe personal injury, or death. These servicing instructions are for use by qualified personnel only. To reduce the risk of do ��, f D I SAFETY HAZARD! Operating the unit without the access panels properly installed may result in severe personal injury or death. Do not operate the unit without the evaporator fan access panel or evaporator coil access panel in place. •... \ � � •GAS �I '''`-- �-- 14 `• I �,,,, % ! i COMPRESSOR SCROLL SCROLL CHARGING VOLTS/PH/HZ 208-230/1/60 208-230/1/60 SPECIFICATIONS < R.L. Amps -L.R. 15.4/ 83.9 15.4/ 83.9 Subcooling no no Amps PIPE 512E (in,) 1/2 1/2 OUTDOOR COIL- TYPE SPINE -FIN SPINE -FIN DIMENSIONS H X D X W H X D X W TAG: �_ 'III, // �d� ✓ Rows/F.P.I 2 / 24 2 / 24 Crated (In.) 48 X 45 X 52 48 X 45 X 52 Face Area (sq. ft.) 15.49 15.49 WEIGHT Tube Size In.) 3/8 3/8 Shipping (lbs.) / Net 438/374 453/379 electrical shock, not perform any servicing other than that contained in these oeratin p g instructions unless you are qualified to do so. Important:( p appropriate gloves, arm sleeve protectors and eye protection when INDOORCOIL- (lbs.) TYPE MCHE MCHE _ (a) Rated In accordance with AHRI Standard 210/240, AHRI standard Rows/F.P.I 2 / 16 2 / 16 rating conditions are: 80 D,B.67 W.B. entering air to indoor coil. 95 D. B. entering air to outdoor coil. servicing or maintaining this equipment. Important: Air filters and media wheels or plates shall meet the test requirements in UL 900. ©2014 Trane 4YCC4036A-SUB-1 B -EN Face Area (sq. ft.) 2.7 2.7 (b) Sound Power values are not adjusted for AHRI 270-95 tonal Tube Size Width (in.) 1 1 corrections. (c) Ratings shown are for to 2000 ft. For higher Refrigeration Control EXPANSION VALVE EXPANSION VALVE elevations up elevations reduce ratings at a rate of 4% per 1000 ft. elevation. Drain Conn. Size (In.) 3/4 FEMALE NPT 3/4 FEMALE NPT (d) Convertible to LPG. (a) This OUTDOOR FAN - TYPE SWEPT SWEPT value is approximate. For more precise value, see Unit Nameplate. (0 Standard Air - Dry Coil - Outdoor. DIA. (IN.) 23.4 23.4 (g) Based on U.S. Government Standard Tests. DRIVE/NO. SPEEDS DIRECT/ 1 DIRECT/ 1 (h) Filters must be installed in return air stream. Square footages listed based 300 f.p.m. face CFM @ 0.0 in. w.g. (0 3080 3080 are on velocity. If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C. 4YCC4036A-SUB-1B-EN 3 A SAFETY WARNING Only qualified personnel should install and service the equipment. The installation, starting air-conditioning equipment can be hazardous and requires specific knowledge and training. equipment by an unqualified person could result in death or serious injury. When working literature and on the tags, stickers, and labels that are attached to the equipment. up, and servicing Improperly installed, on the equipment, of heating, ventilating, and adjusted or altered observe all precautions in the December 2014 4YCC4036A-SUB-1 B -EN ��IngersollRand Outline Drawings Figure 1. 4YCC4024-4036 Outline Drawings Outline Drawings Figure 2. 4YCC4024-4036 __- • � Figure 3. 4YCC4024-4036 -+ 1487. I1 :::-..-..-i51.37 f. 158-9!161 16.3/16) 11.56 jjjj (15/321 1 y INLET rtfr i� Ik? O1)1 1 ,, ,,, �� ii ..,lir 1210.28 118.211321 .• D '�' 17.78 (DUCT FLANGE) (11/161 w2 W3 I�� Gl 00- ►I C INLET 97.96 , ��` \-j 11`).. . " 91 I. 3 \� i1��. 41Itik�i►!--' \ :\`�i�1 .\��.' ` [9.18] _�/ 0 398.22 [ 15-1 i / 16 ] • '� rs -All 0-00o0-00.--,,----'0-0-__---; :..---:----1:..---..'------ J0.0/...... SUPPLY ,„(OUTSIDE) ,�i!G ♦�owe /'�"'''i 0"00-0l1/i l •- r 4.s'• / � ,. ^ - �� .. '"...00D RETURN I 176.07 [6-15/16] �- �--- 398.22 [ 15 96 .62 / i s ] (OUTSIDE) 58.19 [2-9/32] 117.55 [7] -1 1 / 16 ] 111.56 1 151321 (DUCT FLANGE) (3.21/321 is TYPICAL 181 SIDES OF SIDEFLOW DUCT OPENINGS nzs zz ,. ^' �,.,, -^' %//iii//i//��a Al �0\ d INLET ' s w2 . _ w3��f�1k 109.99 ✓ ( �1'�ijls//� �s„ 1 --�•. -.^-.h,� A� �� ll 111. 1161 INLET 11 t I����`�,.`„11)t1 Yt;,;�r��i��illll� 12Di721 1232321 �`\��OYt�\ r/�7/��/, "-r.-- , �, LUE B U3•I/81 + • 1� INLET-� ����[' u� }'I� /• ` INLET :_--•.///'' 11.z2 (9/161 ....-�:..-.•_,,./ 101 61 [7.1116) 18.03 123/321 ..---- -1- 18.29 113/321 B \` `�\'/// - , \`\°`• FLUE HOOD Y -Y WI NI SECTION TOPICAL 181 SIDES OF DONATION DUCT OPENINGS IN TOP ET SIDE ENTER OF GRAVITY 14.22 (91161 /�" 201.63 n•1i/161 OUTLET wl '-� N/ 1 SECT ION Y•Y TYPICAL 181 SIDES OF DONATION DUCT OPENINGS IN TOP ET SIDE ENTER OF GRAVITY (OUTSIDE) •~_� OUT4 LET BACK DUCT OPENINGS ;` - • A - • - • A r 11.18 [11/161 • - • 530.60 120.1!81 25.10 FRONT SIDE I , SECTION X•X ue •I . • TYPICAL 181 SIDES OF SIDEFLOW DUCT OPENINGS ° (11 SSI.13 121.23/321 LEFT ONDENSATE DRAIN FOR 19.0 13/41 FEMALE NPT SIDE 1155.16 [45.1/21 (SURFACE BACK SIDE AREA) - • - (U DRAIN NFRONT SIDE RECOMMENDED SERVICE CLEARANCE MM/IN. 118.23 118.23/321 LEFT 19.0 13/41 FEMALENSATE 19NPT SIDE WITH O.A. DAMPER/ECON. O' BACK SIDE 304.8 1121 762.0 1301 • O LEFT SIDE 914.1 1361 1066.8 1421 / "Bottom �� ■ ^t I, O 4t�,� Height mm/In Flu Hood w/brkt mm/ln Approx. Corner Weight - kg / lbs Shipping Total Unit Center of Gravity mm/In RIGHT SIDE 914.4 1361 . A D WI W2 W3 W4 Weight kg/lbs Weight kg/lbs 8 C FRONT SIDE 1066.8 (421 4YCC4024 (060) 898.53 [35-3/8] 157.16 [6-3/16] 58.3 [129] 36.8 [81] 26.1 [58] 41.0 [90] 196.1 [432] 162.4 [358] 479.8 [18.9] 527.8 [20.8] Note: The view labeled side"• represents the base as viewed looking • / " ' 4YCC4030 (070) 898.53 [35-3/8] 157.16 [6-3/16] 61.3 [135] 38.7 [85] 27.5 [61] 43.1 [95] 204.8 [451] 171.1 [377] 406.5 [16.0] 594.1 [23.4] CLEARANCE TO COMBUSTIBLE MATERIAL MM/IM. Y from the 4YCC4036 (070) E 949.33 [37-3/8] 157.16 (6-3/16] 61.1 [134] 38.3 [84] 27.1 [60] 43.2 [95] 203.4 [438] 169.7 [374] 414.3 [16.3] 697.6 [27.5] J j I up underneath unit. BOTTOM 0 / 4YCC4036 (090) 949.53 [37-3/8] 157.16 [6-3/16] 61.7 [136] 38.9 [86] 27.7 [61] 43.7 [96] 205.7 [453] 172.0 [379] 414.3 [16.3] 697.6 [27.5] BACK SIDE 25.4 111 4YCC4036A-SUB-IB-EN 5 ' t0 LEFT SIDE 152.1 161 RIGHT S1DE 304.8 1121 FRONT SIDE 304.8 1121 TOP 911.1 (36] BOTTOM SIDE _____ 6 4YCC4036A-SUB-I6-EN BOTTOM SIDE6012. 4 4YCC4036A-SUB-IB-EN REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 9 2018 City of Tukwila RECEIVED CITY OF TUKWILA JAN 222018 PERMIT CENTER 329 WELLS AVE. S. RENTON, WA 98057 206.679.3268 SHEET DESCRIPTION '410 GAS 31 CO\VETHLE PAC (Pc . ILECT <AGE 1 2) 2018-0002 GENERAL NOTES DATE \ / - 1 01.22.2018 V . 1 SCALE No. REVISION/ISSUE DATE STAMPS & CERTIFICATIONS PROJECT NAME & ADDRESS BMK MANAGEMENT COMPANY 981 INDUSTRY DR. TUKWILA, WA 98188 PROJECT No. SHEET 2018-0002 DATE \ / - 1 01.22.2018 V . 1 SCALE NTS Indoor Fan Performance Table 1. Horizontal Airflow 4YCC4036A1070A EXTERNAL STATIC PRESSURE (IN WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 HEAT- LOW CFM 1185 1141 1099 1055 1009 968 920 854 808 731 624 WATTS 241 251 260 270 279 289 299 311 320 306 284 HEAT- HIGH CFM 1386 1354 1311 1276 1238 1198 1164 1069 805 689 596 WATTS 386 399 409 419 430 441 452 432 320 303 298 COOLING - LOW CFM 1131 1092 1058 1022 983 942 899 857 804 - - WATTS 247 254 262 269 277 285 291 300 311 - - COOLING - MED CFM 1256 1223 1193 1167 1136 1101 1065 1026 955 - - WATTS 339 350 358 366 374 383 391 399 386 - - COOLING - HIGH CFM 1402 1372 1344 1316 1289 1241 1144 1025 - - - WATTS 471 479 488 497 506 499 454 406 - - - 4YCC4036A1090A EXTERNAL STATIC PRESSURE (IN WG) HEAT- LOW CFM 1362 1330 1301 1272 1242 1210 1148 - - - - WATTS 429 438 445 455 464 473 458 - - - - HEAT- HIGH CFM - 1366 1338 1310 1280 1234 1153 1038 888 - - WATTS - 474 483 491 501 495 463 413 357 - - COOLING - LOW CFM 1131 1092 1058 1022 983 942 899 857 804 - - WATTS 247 254 262 269 277 285 291 300 311 - - COOLING - MED CFM 1256 1223 1193 1167 1136 1101 1065 1026 955 - - WATTS 339 350 358 366 374 383 391 399 386 - - COOLING - HIGH CFM 1402 1372 1344 1316 1289 1241 1144 1025 - - - WATTS 471 479 488 497 506 499 454 406 - - - Table 2. Down Airflow 4YCC4036A1070A EXTERNAL STATIC PRESSURE (IN. WG) MOTOR SPEED 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 HEAT- LOW CFM 1173 1130 1088 1044 999 958 911 846 800 724 618 WATTS 238 248 258 267 277 286 296 308 316 303 282 HEAT- HIGH CFM 1373 1340 1298 1263 1225 1186 1153 1058 797 682 590 WATTS 382 395 405 415 425 437 448 428 317 300 295 COOLING - LOW CFM 1124 1087 1053 1016 978 938 895 852 800 - - WATTS 246 255 263 271 278 285 293 301 312 - - COOLING - MED CFM 1249 1216 1185 1155 1122 1089 1054 1016 934 - - WATTS 343 351 359 367 376 384 392 400 379 - - COOLING - HIGH CFM 1390 1357 1329 1301 1273 1212 1125 1008 -- - WATTS 476 485 493 501 508 488 449 398 -- - 4YCC4036A1090A EXTERNAL STATIC PRESSURE (IN. WG) HEAT- LOW CFM 1350 1317 1289 1260 1231 1197 1134 - - - - WATTS 432 441 449 456 465 475 453 - - - - HEAT- HIGH CFM - 1349 1319 1292 1264 1206 1118 1009 850 - - WATTS - 474 486 494 503 487 446 401 337 - - COOLING - LOW CFM 1124 1087 1053 1016 978 938 895 852 800 - - WATTS 246 255 263 271 278 285 293 301 312 - - COOLING - MED CFM 1249 1216 1185 1155 1122 1089 1054 1016 934 - - WATTS 343 351 359 367 376 384 392 400 379 - - COOLING - HIGH CFM 1390 1357 1329 1301 1273 1212 1125 1008 -- - WATTS 476 485 493 501 508 488 449 398 -- - 4YCC4036A-SUB-1 B -EN 7 Full Perimeter Roof Mounting Curb 8 Figure 4. 4024 - 4036 Models BAYCURB050A Full Perimeter Roof Mounting Curb • • D CHANNEL END C CHANNEL SIDE The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. ** 42.00 WITH ECONOMIZER WITH 25% FRESH AIR ACCESSORY 4YCC4036A-SUB-1 B -EN Optional Equipment - Filter Rack Figure 5. BAYFLTR101 Filter Rack (4024-4036) BAYFLTR102 (4042-4060) (Mounts in Filter/Coil Section) Figure 6. BAYACCDORIA Hinged Filter Access Door (4024-4036) BAYACCDOR2A (4042-4060) Replaces Filter/Coil Access Panel Note: The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 4YCC4036A-SUB-1 B -EN 9 REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 9 2E118 City of Tukwila Optional Equipment - Economizer Table 3. BAYECON101,102A Down Discharge Economizer and Rain Hood (Mounts Over Horizontal Return Air Opening) HVAC Unit SERVICE CLEARANCE DIMENSIONS Unit Application Models A B C D WC10/TC10 42.00 36.00 12.00*; 24.00 DC./YC, 42.00 36.00 12.0010. 36.00 ** 42.00 WITH ECONOMIZER WITH 25% FRESH AIR ACCESSORY 4YCC4036A-SUB-1 B -EN Optional Equipment - Filter Rack Figure 5. BAYFLTR101 Filter Rack (4024-4036) BAYFLTR102 (4042-4060) (Mounts in Filter/Coil Section) Figure 6. BAYACCDORIA Hinged Filter Access Door (4024-4036) BAYACCDOR2A (4042-4060) Replaces Filter/Coil Access Panel Note: The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 4YCC4036A-SUB-1 B -EN 9 REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 9 2E118 City of Tukwila Optional Equipment - Economizer Table 3. BAYECON101,102A Down Discharge Economizer and Rain Hood (Mounts Over Horizontal Return Air Opening) HVAC Unit Economizer Unit Application Models BAYECON lO1A 4024-036 , \ Economizer. rain hood ---.-.�..r.o 01 '` 0 0 0 01 0 00 o 0 001 • tOutside BAYOSAHOO1A Mist ��� eliminator ' U . L , ''/ air dampers Return air dampers \ , / Required ,,,,---filter kit, order / separately BAYECON102A 4042-060 • BAYOSAHOO2A 4042 - 4060 �l Relief damper C Return Duct Roofcurb/ A...__ _ Table4. BAYCON200, 201A Horizontal Economizer and Rain Hood 11)... ,44` \� \ FULLY OPEN Manual Fresh Air Model licit Application Models A B .-• Economizer BAYOSAHOO1A 4024-4036 e 20-11/16" 12-3/8" 9-3/16" 22-7/16" 20-11/16" FULLY B CLOSED \ BAYOSAHOO2A 4042 - 4060 • Duct C �_ � II �< I4 -D-► _ II I , I Gaskets (2) Rain Hood -4---- - / Mixed Air Sensor ' Economizer Models A B C D E F BAYECON200AA 4024-4036 22" 20" 16-7/8" 15-11/16" 11-11/16" 15" BAYECON201AA 4042-4060 26" 22-21/32" 19" 17-11/16" 14-11/16" 21-3/8" Note: The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not Intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer Is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 10 4YCC4036A-SUB-1 B -EN Optional Equipment - Outside Air Damper Table 5. BAYOSAH001 and 002A Table 6. BAYDMPR101 and 102A, 25% Motorized Outside Air Damper (Mounts Over Horizontal Return Air Opening) ice `` ,44` i \ FULLY OPEN Manual Fresh Air Model licit Application Models A B C D BAYOSAHOO1A 4024-4036 22-7/16" 20-11/16" 12-3/8" 9-3/16" 22-7/16" 20-11/16" FULLY B CLOSED \ BAYOSAHOO2A 4042 - 4060 25-3/16" 20-11/16" 12-3/8" 9-3/16" Table 6. BAYDMPR101 and 102A, 25% Motorized Outside Air Damper (Mounts Over Horizontal Return Air Opening) ice `` A i ` GAS ELECT . 2-2) GENERAL NOTES -t B i Manual Fresh Air Model Unit Application Models A B C D BAYDMPR101A 4024 - 4036 22-7/16" 20-11/16" 12-3/8" 9-3/16" BAYDMPR102A 4042 - 4060 25-3/16" 20-11/16" 12-3/8" 9-3/16" I4 -D-► _ Note: The drawings on this page are prepared by the manufacturer In order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer Is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 4YCC4036A-SUB-1 B -EN 11 Mechanical Specifications General The units shall be horizontal airflow as shipped and convertible to downflow. All units shall be factory assembled, piped, internally wired and fully charged with refrigerant. Units shall be certified to UL Standard 1995. Units shall be designed to operate at ambient temeratures as high as1150 F. Cooling performance shall be rated in accordance with AHRI standards. The YC heating/cooling unit design is certified to ANSI 221.47/CSA 2.3, specifically for outdoor applications using natural gas or propane. All units shall be designed for outdoor rooftop or ground level installation. Unit Casing All components shall be mounted In a weather - resistant steel cabinet with an enamel finish. Access panels shall be provided for unit controls and indoor coil and fans. Indoor air section compartment shall be completely insulated with fireproof, permanent, odorless fiber material. Knockouts shall be provided for utility and control connections. Drain connections shall be provided to accommodate indoor water runoff. Compressor The compressor shall be hermetically sealed, high efficiency scroll compressors. Internal overcurrent and overtemperature protection, internal pressure relief shall be standard. Other features include centrifugal oil pump, low vibration and noise. Refrigeration System All units shall have refrigerant control. Service pressure tap ports and a refrigerant line filter shall be standard. Evaporator Coil (2-4 Ton Models) All aluminum micro channel, extruded tubes, mechanically bonded to aluminum fins, and factory pressure and leak tested at 480 -650 psig. All units have TXVto control refrigerant flow. Condenser Coil The Spine Fin TM condenser coil shall be continuously wrapped, corrosion resistant all aluminum with minimum brazed joints. This coil is 3/8" OD seamless aluminum tubing glued to a continuous aluminum fin. Coils are lab tested to withstand 2.000 pounds of pressure per square inch. The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Indoor Air Fan 12 Constant Torgue, forward -curved, centrifugal wheel in a Composite Vortica ® Blower housing. Motor shall have thermal overload protection and permanently lubricated motor bearings. Motor/blower assembly isolated from unit with rubber mounts. Outdoor Fan One direct -drive, statically dynamically and d namicall balanced propeller fan shall be used in a draw -through vertical discharge configuration. Permanently lubricated weather proof motor shall have built-in thermal overload protection. System Controls System controls include condenser fan, evaporator fan and compressor contactors. Accessories Roof Curb The roof curb shall be designed to mate with the unit and provide support and complete weathertight installation when properly installed. Adhesive back polyurethane sealing strips shall be provided to ensure an airtight seal between supply and return openings of the curb and unit. The roof curb design allows field fabricated ductwork to be connected directly to the curb. Curb ships knocked down for field assembly, and includes factory installed wood nailer strips. Heating System Gas -Fired Heating Section Models shall provide completely assembled, wired and piped gas fired heating systems within unit. Design certified by UL, specifically for outdoor application. Threaded gas connection on the unit. Electric Ignition System Main burner is lit each time thermostat calls for heat. Flame sensorroves flame and keeps the main burner p p on. Should a loss of flame occur, the main valve closes and the spark recurs within 0.8 seconds. When thermostat is satisfied, main burner is extinguished. Forced Combustion Blower Insures flame stability under varying wind conditions. Gives higher combustion efficiency and location flexibility. Heat Exchanger Stainless steel tubes. Free floating design. Burners Stainless steel. Multi -port inshot. 4YCC4036A-SUB-18-EN Mechanical Specifications Single Source Power Entry This accessory when used with electric heat accessory shall allow single source power connection to unit and heater combination. Single source power entry kits shall have specific matching heater(s). Kit shall include high voltage terminal blocks, fuse blocks and fuses, cut - to -length interconnecting wiring, and junction box (if required) to provide power sources with fuse protection as required for both the unit and accessory heater. Kit components shall install within the heater cabinet in the heater access section. Single source branch power circuit shall be protected and wired in accordance with local codes. Fully Modulating Economizer This accessory shall be field installed and be composed of the following items: 0-100 % fresh air damper, damper drive motor, fixed dry bulb enthalpy control, and low voltage pigtails for electrical connections. Solid state enthalpyor differential enthalpycontrol is optional. Economizer operations shall be controlled by the preset position of the enthalpy control. A barometric relief damper shall be standard with the economizer and provide a pressure operated damper that shall be gravity closing and prohibit entrance of outside air on equipment "off' cycle. Economizer requires BAYRLAY004A relay kit to interface the economizer to the heat pump. Manual Outside Air Dampers Rain hood and screen shall be field installed. Suitable for up to 25% outside air. Start Kit Extra compressor starting capacity for single phase equipment. Control Options Standard Indoor Thermostats Two stage heating/cooling or one stage heating/cooling thermostats shall be available in either manual or automatic changeover. Programmable Electronic Night Setting Thermostat Programmable electronic thermostat shall provide heating setback and cooling setup with 7 -day programming capability. 1 H/1C or 2H/2C models available. ceus Intertek RECEIVED CITY OF TUKWILA JAN 2 2 2018 PERMIT CENTER CERTIFIED*; Uuttvy Smell Ar AUHI tmd nd 17 ,, n Cl �b f {p �Vynf [ �y1efC; K%IwN It AlltE The manufacturer optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, the manufacturer offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.IRCO.com. The manufacturer has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. ©2014 Trane 4YCC4036A-SUB-1B-EN 01 Dec2014 Supersedes 4YCC4036A-SUB-1A-EN (November 2014) ()Ingersoll Rand bora ICC INTESTATE CAPITAL CORPOATIO\ DESIGN TEAM 329 WELLS AVE. S. RENTON, WA 98057 206.679.3268 SHEET DESCRIPTION '410 3T CO\VETHLE DACX(AGE (Pc GAS ELECT . 2-2) GENERAL NOTES DATE 01.22.2018 v 1 .2 - SCALE No. REVISION/ISSUE DATE STAMPS & CERTIFICATIONS PROJECT NAME & ADDRESS BMK MANAGEMENT COMPANY 981 INDUSTRY DR. TUKWILA, WA 98188 PROJECT No. SHEET 2018-0002 DATE 01.22.2018 v 1 .2 - SCALE NTS