Loading...
HomeMy WebLinkAboutPermit M18-0013 - INNOVASIAN - WALK-IN FREEZERINNOVASIAN 116 ANDOVER PARK E M18-0013 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov MECHANICAL PERMIT 0223000060 Permit Number: M18-0013 116 ANDOVER PARK E INNOVASIAN Issue Date: 2/23/2018 Permit Expires On: 8/22/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: PIETROMONACO/PB L L C 7900 SE 28TH ST STE #310 , MERCER ISLAND, WA, 98040 TREVOR SUK 401 NE RAVENNA BLVD PMB 130 , SEATTLE, WA, 98115 POLAR BEAR MECHANICAL INC 401 NE RAVENNA BL, SUITE 130, SEATTLE, WA, 98115 POLARBM891PC //1 Phone: (206) 419-8522 Phone: (425) 967-5827 Expiration Date: 10/3/2019 DESCRIPTION OF WORK: INSTALL OF CUSTOMER PROVIDED WALK-IN FREEZER Valuation of Work: $11,220.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $368.13 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Date: 23� V I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: 5-pe,v1/L12A/E: Date: a � / s This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 4: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4)(EXTEND SPRINKLER PROTECTION TO THE WALK-IN FREEZER.) 2: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 1: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436)_ 3: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 5: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 6: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 7: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 8: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 9: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 10: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 11: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 12: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 13: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 14: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 15: ***MECHANICAL PERMIT CONDITIONS*** 16: All mechanical work shall be inspected and approved under Permit Center (206/431-3670). 17: Manufacturers installation instructions shall be available on PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 0703 1800 0609 0705 0701 FIRE FINAL MECH EQUIP EFF MECHANICAL FINAL PIPE/DUCT INSULATION REFRIGERATION EQUIP ROUGH -IN MECHANICAL a separate permit the job site at the issued by the City of Tukwila time of inspection. CITY OF TUKWII•r Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: �{ - I (For office se o y) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 11 4'000t( PAM CAS -1 Tenant Name: I/VUOVaSIAid SbSF.PN ZAW4 PROPERTY OWNER Name: '127LAt4E'• y LOAA(.4I\it,+- (LbAL (.4Nr6 LLL Address: 503 Am E A .4t.11L 1 City: sm. teo,,,I,v State: TtXRS Zip: `7e41 CONTACT PERSON — person receiving all project communication Name: vncz_ s v Address: toOE RAJ NJA 8wo PM6k30 City: SCA nit State: » Zip: asit 5 Phone:12 co 4-1 11 .. tt 1 5S21 Fax: Email: { 1 llekt , P Do1aJ8E.A1iMGcrlaW cALkt•K • (64k. King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: ❑ Yes ❑ ..No MECHANICAL CONTRACTOR INFORMATION Company Name: i�oiar el -f-- Mt cam,,, ce A Address: ti0 ` tG g. P\) ufi, 6tvcl 0,,k600 City: SeATIe State: W A Zip:1 11c Phone: ( 5) q 6`1 - S `6Z-1 Fax: _ Contr Reg No.: POLAv.s14,tie( Exp Date: i0/ t s Tukwila Business License No..: 5 us _ D qci 15 5 9 Valuation of project (contractor's bid price): $ 1 2,7_ C) o4- CoST0 plocQ -,� Describe the scope of work in detail: i p5-`,o,r w Use: Residential: New ❑ Replacement 0 Commercial: New El Replacement 0 f►t6czoz, o ---- Fuel Type: Electric gi Gas ❑ Other: H:\ApplicationsWorms-Applications On Line\2016 Applicatioas\Mecbanical Permit Application Revised I-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit 65 dB(A) <10,000 cfin 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 1 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-10pm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY T I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJUR : Y THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 1 ' R OR AUTHORIZED AGENT: Signature: Date: Print Name: �11-Day Telephone: k(iItS") 41"S171MailingAddress: N t V-Psv E ioN k N v i Mb 116 U,1%C vl5 H: Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh City State Zip Page 2 of 2 DESCRIPTIONS PermitTRAK Cash Register Receipt City of Tukwila ACCOUNT QUANTITY PAID 368.13 M18-0013 Address: 116 ANDOVER PARK E Apn: 0223000060 3.3,33 368.13 , Credit Card Fee $10.72 Credit Card Fee R000.369.908.00.00 0.00 $10.72 MECHANICAL $343.66 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $241.78 PLAN CHECK FEE R000.322.102.00.00 0.00 $68.73 TECHNOLOGY FEE $13.75 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R13532 R000.322.900.04.00 0.00 $13.75 $368.13 Date Paid: Tuesday, January 23, 2018 Paid By: TREVOR SUK Pay Method: CREDIT CARD 07085Z Printed: Tuesday, January 23, 2018 10:59 AM 1 of 1 CRWSYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: c Mi NI OVr� i Type f Inspection: __ Ai- Ft KAL Address: Me AllidotteA ¢Rtr j< E. Date Called: j- / 2-2X)/dr Special Instructions:Date F1 CkrA-rd (_) �c Q�7 053'&5 - V7.2 Wanted: a.pa! /G( 3 /3 - 2D.f� p.m. Requester: Phone No: EjApproved per applicable codes. Corrections required prior to approval. COMMENTS: % �Lt��rr cam, is /vet s2.47 -cd DF/c ' ' r9 C� /'►/l i vfl s' etre OfPiweee, fl Inspector: n n Date: 3'-13-aO/F- REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: ,NN6NSl* Type of Inspection: Address: ,�, �,//��.�s �,r //', ,`l'7o/%Q R4Pl, Date Called: Special�/j�Instructions: Rr! ( L n /Gi /.2 Date Wanted: a -7 -lo t* p.m. Requester: TAJCW0f. Phone No: _ _•19‘ 755-2-, 121,44pproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: of<- ,i icqu, ,�. Rz51)6./1-4 nspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NUMBER CITY OF TUKWILA FIRE DEPARTNFE INSPECTION RECORD Retain a copy with permit /f—S-032 206-575-440 PERMIT Nr D (3 Project:- /4,iisoYA-Sia:') Sprinklers: Type of Inspection: 5'P.---- : = --- --- Address:Contact Suite #: /(9 Ate- /// Person: -� --- Special Instructions: //USS/. D 1 Phone No.: ,r/A- Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: 7 /// Occupancy Type: -' //USS/. D /2 ;e‘ -z ,r/A- t 1/1)'7/Z /N Seee/- -, Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:` . /4S- 3 Date: 2/2/// 2 Hrs.: ( 0 / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Your Preferred Complete Professional Foodservice Equipment�� Solution, Consultation, Design, Set Up and InstallationREVIEV ED FOR 7 •OOrC OMPLIANCE'', APPROVED From: Continental Equipment, Massoud Sondocie' To: InnovAsian Cuisine - Steven Veme 18251-B Cascade Ave S. Tukwila, WA 98188 425-988-2710 -• ity of Tukwila Stevenv@innovasiancui,in ..cJ4 Re: Price Quotation on Equipment as per your request, Email: Stevenv@innovasiancuisine. xl LDI NO DIVISION sow Date: 12/7/2017 FEB 2 2 2018 Following please find partial equipment pricing and availability. For more information or any question, please contact us at (253) 572-7720. Pricing is good for 30 days only. We will keep the right to change the pricing without any notice. Availability is limited to stock on hand. Manufacturer's price change will affect the pricing. Freight charges may apply to special orders. Delivery charges are not included in pricing. You may reserve any item with a 25% non-refundable down payment. Pricing does not include the local sales taxes.. As per US COOLER, we are as authorized US Cooler dealer in State of Washington are asked to provide this quote. • We will need address of the job site to issue invoice, signed drawing and signed quote is required and receive payment as follow: • 50% of the box and system pius aii sales tax in advance as check issued on the name on Me provided invoice • 500' of t"e box ^and system ;.,hen ., e receive acknowledgment for shippingfrom manufacturer that ....... system ..... acknowledgment avubau..u,..va .� the order has been shipped prior received by you or our company for delivery/set up. • Installation of the box, hang the coils and place the system on no more than 12 ft roof (if higher or any crane or boom truck for roof delivery is required, such expenses with be ackied.). You are welcome to make choice like some customers in Everett (we installed). Seattle (we installed) and West Seattle (buyer installed). This payment will be due after we have finished our box set up. • If you need system installation, we can provide this service as well through our licensed agents. InnovAsien Cuisine - Steven Veme 18251-B Cascad Ave S. Tukwila, WA 98188 425-988-2730 - 1 Walk -In Freezer: 29'-0" X 11'-0" X 9'-0" - 4" urethane, stucco embossed gaivalume 26 gauge exterior, stucco embossed gaivalume 26 gauge interior, nsf approved. �:.-nr• 9Qft Ain X lift Ain_ . Titan FIn r. 4" ortrtutntf inRlllatlnn. wnnti rs_infnrt.eri. 22 flautist stainless steel interior, stucco embossed gaivalume 26 gauge exterior. (5,000 Ibs/sgft, evenly distributed, stationary load. Not designed for the use of ForkIitts, Pallet JACKS, or Hard Wheeled Carts.) RECEIVED 1 Door. 48 in. X 79 in.: low temp inside. with floor. threshold. Vert-Erao handle. LED liaht. LED ttgirruffi[gF T U K W 1 L A switch, door closure and 3 strap hinges, hinge left centered on left width wall , with U.S. Cooler Logo - ---- 1 50" x 30" exterior ramp (usc 1124) 2 LED 4' cooler / freezer Tight fixture Kason part# 11810LX4000 JAN 2 3 2018 PERMIT CENTER Non-cnaraea rireassemolea low temp o system. 9 op.. posse. LU0/LJO VULLS tittiluue ; ,,er,,ieuv *IA Ott compressor, outdoor weather hood, crankcase heater, compressor contactor, high/low pressure control, TLV i 1.etiter otreel. Tacoma. VYA. VO4UV. vine: ILo31o/"L-//[u. rax: izo;nott-/55:f Snnn vicir nc ar• «Www.ilakeryRcslauraniEquiptnenl.com Customer Service and Satisfaction is our No.1 Priority MA IMO Your Preferred Complete Professional Foodservice Equipment Solution, Consultation, Design, Set Up and Installation. receiver, liquid filter/drier/sight glass/moisture indicator, flooded head pressure control valve, electric defrost timer. evaporator, expansion valve and solenoid valve. drain line heater. thermostat is shipped loose. drain line needs to be field installed. does not include refrigerant-r404a eisa compliant (1) BOHN MOZ055L63CF, (2) Bohn EVAP COIL - LET090BEK Price - $5,698.91 Per Unit. Included in total price. Holding Temp (-10)F Ambient Tema 95F Raf TvnP dr1da units 220V/ Three Phase Glop Compliant BTUs Needed 17264 Ref BTUs 19260 Extended 2nd -5th year refrigeration warranty 4 1/2 to 5 hp compressor only crhcus-052-5p (3342) Ptd $695.36 Per Unit included In total price . zst assembly, packaging, and handling - 3'4" x 8'6" x 5' vertical skid 8 - 57" uprights & 2 - 40"bottom boards Test assembly, packaging, and handling - 4' x 11' x 7' flat stack skid Itl Includes 4 pieces of full wrap fiber corners. Price without Options, delivered, unloading in 30 minutes on buyer 29.680.24 Options Not Included Extended refrigeration warranty; - 1st day - 1st year - 4 1/2 to 5 hp labor only crchus-011-5I (7806) Price - $683.94 Per Unit. Not Included in total price. Accept Option Decline Option. Extended refrigeration 4 1/2 to 5 hp warranty, 1st day -5th year labor and 2nd -5th year parts. this warranty includes the 2nd -5th year compressor warranty crchus-011-5I & crchus-052-5 (7806 & 9325) Price - $2,551.53 Per Unit. Not Included in total price. Accept Option _ Decline Option 1. —.Estimated freight to Tukwila, WA 98188 ship direct to you unload 30 minutes. - 2. Lead Time 6 business weeks plus shipping time around 5-7 business days 3. PLEASE NOTE: Shipping does NOT include lift gate or residential area delivery. Additional charges will apply iiilae:aa stated otherwise rrlac eie quote. Changing the chip to Zip code may change the shipping amount due. 4. Standard LTL Loads have Maximum 30 Minute unload time, over this additionai detention ;viii inf.71;r 5. **If a valid Sales Tax Certificate, for the states listed, is not on file with us. the dealer will hp rpsnnnsihlp fnr taYpc. 6. Taxes are teased nn the date 4h= nr'Jnr s uvea nut irlciuue adios taws wiii apply. A iaesirniie of lire signed original of this form shall have the same force and effect as the original and shall, upon receipt by Craig iiiuusiries, inc. be birKlirry un both parties. AI I AQU^TATI^NS "BE G^^0 F^R 30 ^P.Ye. This does not include sales tax. A^plicable laws will anniv 9. All refrigeration components must be installed by a certified refrigeration contractor and one must be present at refrigeration unit startup. Failure to utilize certified refrigeration contractor may affect 3. i iaiy inuusiries reserves fire rigid to modify ur eorreci ail quotations as necessary. UL listed core nniv 11. Total cost shipped directly, you will have 30 minutes to unload or will be subject to detention. 12. US COOLER BOXES ARE FROM EXTRUDED POLYSTYRENE WITH SELF CLOSING FLUSH MOUNTED DOOR, 4 INCH HIGH EFFICIENT BOX WITH 828.5 INSULATION Your Preferred Complete Professional Foodservice Equipment Solution, Consultation, Design, Set Up and Installation. VALUE (minimum requirement R25). FREEZER R32,5 INSULATION VALUE R32.5 (minimum requirement R30) 13. ALL OFFERED PARTS AND BOXES ARE PROUDLY MADE IN THE USA, "NSF" and "UL" or equal listed. 14. Signed invoice and full payment plus signed drawing is required to process your order. Thank you for your business. 15. Optional: We accept freight, deliver, unload, set up, hang the coil, secure door frame, ensure box is sealed air tight, all the required parking for 8 hours on buyer, distance between the truck and cooler location no more than 150 ft, all packaging material disposal on buyer ($150.00 will be added for material handling), , hang the evaporator and place the condensing unit on top of the box or anywhere else less than 12 ft. high easy access, dedicated time since parked, assembled and left 24 hours total or $95.00 per extra hour will be added. Street level installation or extra charges for stairs, basement or second floor will be added. If hallway not wide or long enough, extra charges may apply. LEVEL FLOOR IS REQUIRED. Packaging material disposal on buyer. All electrical, drain, permit, fees and refrigeration installation on buyer (we can provide this service at additional cost) PER HOURLY CHARGE $95/hour (total two employees and truck) estimated 24 hours Estimated $2280 NOTE: All electrical, drain and heated insulated drain for freezer line is on buyer or we will add for such service NOTE: Price reflects 2.75% discount for cash payment, wire transfer, check with letter of guarantee, cashiers check and check with 10 business days to be cleared. Other method of payments will be charged 2.75% handling and non- cash payment processing fee, American Express cards orocessin �a fee is 3.89% If you may have any question, please call me (253)572-7720. EMAIL: MSondocie@hotmail.com Regards: Massoud Sondocie. Director Partner rr, r.ianinn this hmr order, please slop/elate and mail your clown payment with your purchase order. We can make appointment for Iookina at the site for accurate box and system installation. Thank you. Name: Business Name and address: Signature: Date: I AO; DNAwnr. Gu,nc . d 6;30' BOO S2' 206521 x 1291421 fox 2 ! 1 228 2424 www ✓stool«corn U.S. Cooler Walk-in Coolers and Freezers 1. Refrigeration A) Walk-in Refrigerator and Freezer Construction 1) General: Each panel shall consist of inner and outer metal skins, a 4" insulation core, and be equipped with cam -action locking devices. The locking devices shall be operable from inside the walk-in. Cam plug buttons are provided to cover the holes after assembly is complete. Construction shall be as approved by the NSF International and shall bear the NSF® Seal of Approval. All panels shall be connected to one another by placing the tongue of the insulation core of one panel into the groove of the core insulation of the adjacent panel. The resultant tongue and groove joint shall be sealed at both sides by double barreled NSF® approved gaskets. In order to avoid future swelling and mold formation, no wood shall be permitted in the manufacture of the tongue and groove panel profile. (a) Wall Panels: Panel insulation shall be 4" thick, high quality, extruded polystyrene or foamed -in-place polyurethane, modular panels joined by not less than three (3) cam -lock devices; gasket to seal between panels; R-28 or greater for refrigerators and R-32 or greater for freezers. (i) Refrigerators: (a) Extruded Polystyrene: All wall insulation shall be 4" thick, high q rigid extruded polystyrene, 1.61b density. K factor of not more th and an R -factor of not less than 7.2 per inch, initial fresh R-28.8 total wall R factor. Vapor transmission shall be less than 1 perm core material must meet UL 5 flame spread rating with average s rating less than 165 (UL 723 test). (b) Foamed in-place Polyurethane: All wall and ceiling insulation sha ` be 4" thick, high quality, foamed in-place polyurethane, 2.21b density. factor of not less than .141 and an R -factor of not less than 7.1 per inchtial ci fresh R-28.4 minimum total wall R factor. Vapor transmission shf alitirt than 1 perm and foam core material must meet: UL Foam Core 25 spread rating with average smoke rating less than 450. (ASTM E-84) .1REVIEWED FOR ill#199E COMPLIANCE d foamAPPROVED oke FEB 2 2 2018 (ii) Freezers: (a) Extruded Polystyrene: All wall insulation shall be 4" thick, high quality, rigid, extruded polystyrene, 1.6 Ib density. K factor of not more than .125 and an R factor of no less than 8.1 per inch, initial fresh R-32.4 minimum total wall R factor. Vapor transmission shall be less than 1 perm and foam core material must meet UL 5 flame spread rating with average smoke rating less than 165 (UL 723 test). (b) Foamed -in-place Polyurethane: All wall and ceiling insulation shall be 4" thick, high quality foamed in- place polyurethane, 2.2 Ib. density. K factor of not more than .125 and an R factor of no less than 8 per inch, initial fresh R-32 minimum total walls R factor. Vapor transmission shall be less than 1 perm and foam core material must meet: UL Foam Core 25 flame spread rating with average smoke rating less than 450. (ASTM E-84) (b) Ceiling: Panel insulation shall be 4" thick, high quality, extruded polystyrene or foamed -in-place polyurethane, modular panels joined by not less than three (3) cam -lock devices; gasket to seal between panels; R-28 or greater for refrigerators and R-32 or greater for freezers. (a) Refrigerators: tt�yggof Tukwila RECEIVED CITY OF TUKWILA JAN 2 3 2018 PERMIT CENTER MR, flOL'b i. Extruded Polystyrene: All ceiling insulation shall be 4" thick, high quality rigid extruded polystyrene, 1.6 Ib density. K factor of not more than .139 and an R -factor of not less than 7.2 per inch, initial fresh R- 28.8 minimum total wall R factor. Vapor transmission shall be less than 1 perm and foam core material must meet UL 5 flame spread rating with average smoke rating less than 165 (UL 723 test). ii. Foamed in-place Polyurethane: All wall and ceiling insulation shall be 4" thick, high quality, foamed in-place polyurethane, 2.2 Ib density. K factor of not less than .141 and an R -factor of not less than 7.1 per inch, initial fresh R-28.4 minimum total wall R factor. Vapor transmission shall be less than 1 perm and foam core material must meet: UL Foam Core 25 flame spread rating with average smoke rating less than 450. (ASTM E-84) (b) Freezers: i. Extruded Polystyrene: All ceiling insulation shall be 4" thick, high quality, rigid, extruded polystyrene, 1.61b density. K factor of not more than .125 and an R factor of no less than 8.1 per inch, initial fresh R-32.4 minimum total wall R factor. Vapor transmission shall be less than 1 perm and foam core material must meet UL 5 flame spread rating with average smoke rating less than 165 (UL 723 test). ii. Foamed in-place Polyurethane: All wall and ceiling insulation shall be 4" thick, high quality, foamed in-place polyurethane, 2.21b density. K factor of not less than .141 and an R -factor of not less than 7.1 per inch, initial fresh R-28.4 minimum total wall R factor. Vapor transmission shall be less than 1 perm and foam core material must meet: UL Foam Core 25 flame spread rating with average smoke rating less than 450. (ASTM E-84) (c) Rain Roof Package: When specified. For use on walk-ins installed outdoors. Specify whether walk-in is free standing or which wall is butted against the building. A single -ply membrane roof shall be supplied to provide water resistant covering of the ceiling panels. Membrane materials shall be provided in one complete roll designed for the size of the walk-in. No welding of seams shall be required for installation. (d) Sloped Roof Package: When specified. For use on walk-ins installed outdoors. May be required at certain snow loads. In order to form a sloped roof profile, suitable quantities of sloped foam shall be provided. The foam shall be cut in a manner that upon installation, a'/":1' slope is obtained. The membrane roof shall be increased in size appropriately, in order to provide the additional material required to properly cover the resultant profile. (e) U.S. Cooler panels are rated to withstand up to 90 mph winds. Load calculations must be performed on individual construction to confirm wind loads. Increased wind loads can be achieved with additional support. (c) Finishes: (i) Exterior Finishes: (a) 26 gauge stucco embossed galvalume (b) 26 gauge stucco embossed galvanized steel (c) 26 gauge white stucco embossed galvanized steel (d) 26 gauge tan stucco embossed galvanized steel (e) 26 gauge black stucco embossed galvanized steel (f) 24 gauge smooth stainless steel (ii) Interior Finishes (a) Wall Panels: i. 26 gauge stucco embossed galvalume J ii. 26 gauge stucco embossed galvanized steel iii. 26 gauge white stucco embossed galvanized steel iiii. 26 gauge tan stucco embossed galvanized steel v. 26 gauge black stucco embossed galvanized steel vi. 24 gauge smooth stainless steel (b) Ceiling Panels: i. 26 gauge stucco embossed galvalume ii. 26 gauge bright stucco embossed galvanized steel iii. 26 gauge white stucco embossed galvanized steel iiii. 26 gauge tan stucco embossed galvanized steel v. 26 gauge black stucco embossed galvanized steel vi. 24 gauge smooth stainless steel. (c) Floors: i. 22 gauge smooth stainless steel ii. 20 gauge smooth galvanized steel (used for use with quarry tile application) iii. .100 Aluminum (when specified) (d) Panel Dimensions: (i) Wall Panels: (a) Maximum panel height - 20' (maximum enclosure height is 20'4" including the 4" ceiling panel) (b) Maximum panel width - 47" (ii) Ceiling Panels: (a) Maximum ceiling panel length - 20' (b) Maximum ceiling panel width - 47" (c) Indoor units: Ceiling supports are required for ceiling spans over 14'. (d) Outdoor units: Depending on snow load, wind load and other environmental variables, a steel frame may be required for support. (iii) Floor Panels: (a) Maximum floor panel length -14' (b) Maximum floor panel width - 47" 2) Partitions: When specified, walk-ins shall be divided into compartments by the use of panels that are constructed in accordance with the specification for all panels. 3) Floor: See item specifications for conditions that apply to this project. (a) Exposed Prefabricated Floor: Prefabricated refrigerator or freezer floor panels must have R-28 rating or greater; allowable stationary load of 600 pounds per sq. ft. when placed on a continuous concrete slab, reinforced floor panels for larger loads are available; verify that building is transit level prior to installing walk-ins; notify Owner and Architect if sub -floor ventilation or heating is required for walk-in freezers; Dealer or Consultant to verify that sub -floor installation conditions are acceptable prior to installing floor and box. (b) Floorless: (i) Floor Screeds: Floor screeds shall be provided for all floorless walk-ins. The screeds shall be vinyl, and have NSF® approved cove both inside and out. 4) Doors: R-25 or greater for refrigerators; R-32 or greater for freezers. Door shall be flush mounted, positioned and hinged; provided with suitable sweep and magnetic gaskets, door closer, one pre -wired vapor proof light fixture, light switch with pilot light, dial thermometer, manual internal lock override, chrome plated cam lift hinges, chrome plated door latches with strike. (i) Outdoor Units: Doors on outdoor walk-ins shall have weather protected light switch and door drip cap. (ii) Freezer Doors: Freezer doors shall be identical to cooler doors, but with the addition of UL approved heater wire on all four sides. Freezer doors shall include a heated pressure relief port in the adjacent panel. (b) Hinges: One cam -lift spring assisted self-closing hinge and one cam -lift hinge. (c) Handle: Kason or Component equivalent with steel reinforced plate inside door panel, pull door handle with cylinder lock, padlock hole and interior safety release; provide common key for all walk-in doors. (d) Door Closer: Kason or spring assisted comparable (e) Vision Panel (If Specified): Not less than 150 square inches; heated; double pain glass for refrigerators and triple pane glass for freezers. (0 Kick plate (If Specified) : 1/8" thick aluminum diamond -tread plate on both sides of door and frame; extend from door bottom to door handle; secure with stainless steel screws; seal perimeter with silicone. (g) Incandescent Light — Single Light Fixture (h) Internal Ramp: 30" deep, various widths, 22 gauge stainless steel, extruded polystyrene; three - 8" non-skid strips, NSF approved (i) External Ramp: 30" deep, varying widths, ''A" steel diamond tread plate, painted safety yellow. (j) Glass Doors: When specified. Glass door openings shall be provided as necessary for the doors being installed. Sill height shall be per customer specification. Wood framing of the opening shall be required to assist with the installation of the glass doors. (k) Optional Doors: Optional sliding and overhead doors are available; customer to specify. (1) Electrical: Wire surface mounted on door panel to junction box top of door. (m) Thermometer: See item specification for thermometers required for this project: Thermometer installed flush -mount on hinge side of door panel. (n) Digital Thermometer (optional): 3" round digital thermometer with probe, installed flush -mount on hinge side of door panel. (o) Digital Thermometer with Alarm (optional): Specifications available. 5) Pressure Relief Port: Provide heated relief port in freezers, non -heated relief port available upon request for refrigerators; located in exposed wall 6) Lights: (a) Fluorescent: 4' vapor proof; optional per customer specification. (b) Incandescent: Single bulb, vapor proof; installed on door panel. (c) LED: Single bulb or 4' vapor proof; optional per customer specification. 7) Sprinkler Heads: When required, cut holes for sprinkler heads; provide stainless steel trim cap and seal holes. 8) Installation: Dealer to install walk-in units. (a) Drawings and Instructions: Manufacturer shall supply a set of installation instructions and lay -out drawing. All panels shall have panel identification corresponding with the lay -out drawing to facilitate rapid and accurate field erection. B) Refrigeration System: Complete operating system consisting of a condensing unit and a evaporator coil. 1) Condensing Unit: See item specification for condensing unit requirement for this project. (a) General: Condenser fan motors of under 1 h.p. must use electronically commutated (EC) motors or permanent split capacitator-type (PSP) motors; splash lubrication system using Mobil EAL Arctic 22 polyester synthetic refrigeration oil; oil sight glass; removable oil drain plug; label indicating oil used; high/low pressure control; suction line filter; suction and discharge service valves and copper/brass vibration isolators; receiver with fusible plug or relief valve; liquid line shut-off valve; sight glass; molecular sieve filter dryer; main power supply fused disconnect switch (b) Air -Cooled: Air-cooled condenser with ball-bearing permanently lubricated fan motor. (c) Outdoor: Weather proof housing; crank case heater and low ambient temperature controls required to insure proper and efficient operation; fan cycling controls where ambient temperatures do not fall below -15°; head master valve and oversized, heated, insulated receiver and lines where ambient temperatures fall below -15°F. 2) Evaporator Coil: Forced convection style; match to condensing unit and suspend with air discharged parallel to the ceiling; lifetime sealed motors with inherent motor protection; evaporator fan motors of under 1 hp and less than 460 volts must use electronically commutated (EC) motors; enclose coil section and fans within aluminum housing (a) Refrigerator: Air defrost (b) Freezer and Low Temperature Refrigerator: Electric heater and controls for positive automatic defrost (c) Installation: Hang using plastic or nylon fasteners; spread coil weight evenly over ceiling panels; support long span ceiling panels as required. A Division of Craig Industries, Inc. 4 401 Delaware, Quincy, IL 62301 800.521.2665 217.228.2421 Fax: 217.228.2424 www.uscooler.tom EXTRUDED POLYSTYRENE SPECIFICATIONS GENERAL Walk-ins shall be constructed of prefab, precision -formed, modular panels designed for accurate, rapid field assembly. Walk-ins shall be test assembled at the factory. DRAWINGS AND INSTRUCTIONS Each walk-in shall have a set of installation instructions and lay -out drawing. All panels shall have panel identification corresponding with the lay -out drawing to facilitate rapid and accurate field erection. PANEL CONSTRUCTION Each panel shall consist of inner and outer metal skins, a 4" insulation core, and be equipped with cam -action locking devices. The locking devices shall be operable from inside the walk-in and a hex -shaped wrench shall be supplied. Press-fit plug buttons shall be provided to seal wrench holes after assembly is complete. Construction shall be as approved by the National Sanitation Foundation International and shall bear the NSF® Seal of Approval. All panels shall be connected to one another by placing the tongue of the insulation core of one panel into the groove of the core insulation of the adjacent panel. The resultant tongue and groove joint shall be sealed at both sides by double barreled NSF® approved gaskets. In order to avoid future swelling and mold formation, no shall be permitted in the manufacture tongue and groove panel profile. PARTITIONS When specified, walk-ins shall be divid compartments by the use of panels th constructed in accordance with the specifications for all panels. FLOOR SCREEDS Floor screeds shall be provided for all floorless walk-ins. The screeds shall be vinyl, and have NSF® approved cove both inside and out. PANEL FINISH Metal finish of the panels shall be as follows. (Specify finish desired, combinations may be used) Interior or exterior walls, ceilings, and exterior floors • 26 gauge stucco embossed galvalume • 26 gauge bright stucco embossed galvanized steel • 26 gauge white stucco embossed galvanized steel • 26 gauge tan stucco embossed galvanized steel • 24 gauge smooth stainless steel • 24 gauge smooth white galvanized steel Interior floors (When specified) • 22 gauge smooth stainless steel • 20 gauge smooth galvanized steel (used for use with quarry tile application) INSULATION Panel insulation shall be Extruded Polystyrene, manufactured in an HFC and CFC free process, made from 60% recycled materials and 100% recyclable. Door insulation may be Polyurethane. WO EVIEWED FOR fuuDE COMPLIANCE APPROVED d ingEB 2 2 2018 are City of Tukwila BUILDING DIVnC NI RECEIVED CITY OF TUKWILA JAN 2 3 2318 PERMIT CENTER M N• 00 19) 3/21/11 A Division of Craig Industries, Inc. 401 Delaware, Quincy, IL 62301 800.521.2665 217.228.2421 Fax: 217.228.2424 www.uscooler.com Coolers Extruded Polystyrene: All wall and ceiling insulation shall be 4" thick, high quality, rigid extruded polystyrene, 1.6 Ib density. K factor of not more than .139 and an R -factor of not Tess than 7.2 per inch, initial fresh R-28.8 minimum total wall R factor. Vapor transmission shall be Tess than 1 perm and foam core material must meet: Owens Corning - UL Foam Core 5 flame spread rating with average smoke rating less than 175. (UL 723) Dow — UL Foam Core 15 flame spread rating with average smoke rating less than 165. (UL 723) Freezers All wall and ceiling insulation shall be 4" thick, high quality, rigid Extruded Polystyrene, 1.6 Ib. density. K factor of not more than .125 and an R factor of no less than 8 per inch, initial fresh R-32 minimum total walls R factor. Vapor transmission shall be Tess than 1 perm and foam core material must meet UL 5 flame spread rating with average smoke rating less than 165. (UL 723) PASSAGE DOORS (Standard door is 34"x76"; alternate sizes are available upon request). Cooler Doors Door shall be flush mounted, positioned and hinged per drawings. Doors shall be provided with suitable sweep and magnetic gaskets. Door shall be provided with door closer, one pre -wired vapor proof light fixture, light switch with pilot light, dial thermometer, manual internal lock override, chrome plated can lift hinges, and chrome plated door latches with strike. Doors on outdoor walk- ins shall have weather protected light switch and door drip cap. Freezer Doors Freezer doors shall be identical to coolers doors, but with the addition of UL approved heater wire on all four sides. Freezer doors shall include a heated pressure relief port in the adjacent panel. Door Options Customer shall specify requirements for 3 hinges, view windows, locking bars, internal ramps, external ramps, and diamond tread plate. Optional Doors Optional sliding and overhead doors are available; customer to specify. GLASS DOORS (When specified) Glass door openings shall be provided as necessary for the doors being installed. Sill height shall be per customer specification. Wood framing of the opening shall be required to assist with the installation of the glass doors. RAIN ROOF PACKAGE (When specified) (For use on walk-ins installed outside) (Specify whether walk-in is free standing or which wall is butted) A single -ply membrane roof shall be supplied to provide a water resistant covering of the ceiling panels. Membrane material shall be provided in one complete roll designed for the size of the walk-in. No welding of seams shall be required for installation. SLOPED ROOF PACKAGE (When specified) (For use on walk-ins installed outside) (May be required at certain snow Toads; consult U.S. Cooler) In order to form a sloped roof profile, suitable quantities of sloped foam shall be provided. The foam shall be cut in a manner that upon installation, a %":1' slope is obtained. The membrane roof shall be increased in size appropriately, in order to provide the additional material required to properly cover the resultant profile. A Division of Craig Industries, Inc. 1 401 Delaware, Quincy, IL 62301 800.521.2665 217.228.2421 Fax: 217.228.2424 wvw+.uscooler.com FOAMED -IN-PLACE POLYURETHANE SPECIFICATIONS GENERAL Walk-ins shall be constructed of prefab, precision -formed, modular panels designed for accurate, rapid field assembly. Walk-ins shall be test assembled at the factory. DRAWINGS AND INSTRUCTIONS Each walk-in shall have a set of installation instructions and lay -out drawing. All panels shall have panel identification corresponding with the lay -out drawing to facilitate rapid and accurate field erection. PANEL CONSTRUCTION Each panel shall consist of inner and outer metal skins, a 4" insulation core, and be equipped with cam -action locking devices. The locking devices shall be operable from inside the walk-in and a hex -shaped wrench shall be supplied. Press-fit plug buttons shall be provided to seal wrench holes after assembly is complete. Construction shall be as approved by the National Sanitation Foundation Intemational and shall bear the NSF® Seal of Approval. All panels shall be connected to one another by placing the tongue of the insulation core of one panel into the groove of the core insulation of the adjacent panel. The resultant tongue and groove joint shall be sealed at both sides by double barreled NSF® approved gaskets. In order to avoid future swelling and mold formation, no wood shall be permitted in the manufacture of the tongue and groove panel profile. PARTITIONS When specified, walk-ins shall be divided into compartments by the use of panels that are constructed in accordance with the specifications for all panels. FLOOR SCREEDS Floor screeds shall be provided for all floorless walk-ins. The screeds shall be vinyl, and have NSF® approved cove both inside and out. PANEL FINISH Metal finish of the panels shall be as follows. (Specify finish desired, combinations may be used) Interior or exterior walls, ceilings, and exterior floors • 26 gauge stucco embossed galvalume • 26 gauge bright stucco embossed galvanized steel • 26 gauge white stucco embossed galvanized steel • 26 gauge tan stucco embossed galvanized steel • 24 gauge smooth white galvanized steel • 24 gauge smooth stainless steel Interior floors (When specified) • .100 Aluminum INSULATION Panel insulation shall be foamed in-place polyurethane, manufactured with a HFC and CFC free process. 3/21/11 A Division of Craig Industries, Inc. 401 Delaware, Quincy, IL 62301 800.521.2665 217.228.2421 Fax: 217.228.2424 www.uscooier.com Coolers Foamed in-place polyurethane: All wall and ceiling insulation shall be 4" thick, high quality, foamed in-place polyurethane, 2.2 Ib density. K factor of not less than .141 and an R -factor of not Tess than 7.1 per inch, initial fresh R-28.4 minimum total wall R factor. Vapor transmission shall be less than 1 perm and foam core material must meet: UL Foam Core 25 flame spread rating with average smoke rating less than 450. (ASTM E-84) Freezers All wall and ceiling insulation shall be 4" thick, high quality foamed in- place polyurethane, 2.2 Ib. density. K factor of not more than .125 and an R factor of no Tess than 8 per inch, initial fresh R-32 minimum total walls R factor. Vapor transmission shall be less than 1 perm and foam core material must meet: UL Foam Core 25 flame spread rating with average smoke rating Tess than 450. (ASTM E-84) PASSAGE DOORS (Standard door is 34"x76"; alternate sizes are available upon request). Cooler Doors Door shall be flush mounted, positioned and hinged per drawings. Doors shall be provided with suitable sweep and magnetic gaskets. Door shall be provided with door closer, one pre -wired vapor proof light fixture, Tight switch with pilot light, dial thermometer, manual internal lock override, chrome plated can lift hinges, and chrome plated door latches with strike. Doors on outdoor walk- ins shall have weather protected Tight switch and door drip cap. Freezer Doors Freezer doors shall be identical to coolers doors, but with the addition of UL approved heater wire on all four sides. Freezer doors shall include a heated pressure relief port in the adjacent panel. Door Options Customer shall specify requirements for 3 hinges, view windows, locking bars, internal ramps, external ramps, and diamond tread plate. Optional Doors Optional sliding and overhead doors are available; customer to specify. GLASS DOORS (When specified) Glass door openings shall be provided as necessary for the doors being installed. Sill height shall be per customer specification. Wood framing of the opening shall be required to assist with the installation of the glass doors. RAIN ROOF PACKAGE (When specified) (For use on walk-ins installed outside) (Specify whether walk-in is free standing or which wall is butted) A single -ply membrane roof shall be supplied to provide a water resistant covering of the ceiling panels. Membrane material shall be provided in one complete roll designed for the size of the walk-in. No welding of seams shall be required for installation. SLOPED ROOF PACKAGE (When specified) (For use on walk-ins installed outside) (May be required at certain snow Toads; consult U.S. Cooler) In order to form a sloped roof profile, suitable quantities of sloped foam shall be provided. The foam shall be cut in a manner that upon installation, a %":1' slope is obtained. The membrane roof shall be increased in size appropriately, in order to provide the additional material required to properly cover the resultant profile. A Division of Craig Industries, Inc. r 00 CV CV PERMIT CENTER vi QUOTE DRAWING O as a 0 et 0 O W1 t W2 W3 I I U tai I,- U U_ COLL U LOU. U .a U LL C,1 U LL U LL U ii ef PERMIT CENTER vi QUOTE DRAWING O as a 0 et 0 O 1 /2 To 6 HP Indoor & Outdoor Condensing Units Dimensional Drawings OUTDOOR A B C D 1/2,3/4 AND 1HP AIR FLOW LEFT VIEW 28-1/4 1-3/4 1-1/2 AND2HP AIR FLOW ha- 21-1/8 CL 2-9/16 3HP - ALTERNATE CABINET AIR FLOW r 21-1/8 CL 28-1/4 28-1/4 1 2-1/1! SU 49/16 1-11) SU LIQUID 2-9/16 49/16 il 1-3/4 [. LIQUID 2-3/8 • 2-9/1 r. 3HP - ALTERNATE CABINET AIR FLOW r 21-1/8 CL 28-1/4 3,4,5 AND6HP r FLOWIP- 21 •1/8 CL 30-1/4 SUCTION SUCTION 6 2-1/1! SU 49/16 1-11) SU LIQUID 2-9/16 an il i!� 2-5/1 [. 3,4,5 AND6HP r FLOWIP- 21 •1/8 CL 30-1/4 SUCTION SUCTION 6 7/16 DIA HOLE JI TYP 4 PLCS M- 23-1/8 CL 16 FRONT VIEW 37-3/4 19-3/4 _l Pd 1 • 42-1/2 415/16 5-1/4 3-1(4 313(16 29-3/4 z 1• .o. • 6 • 1 15/16 2-1/4 3-11/16 3-11 4 3-1116 41 +16 5-1/4 1-15/16 2-1/4 3 11/16 33 2-1/1! SU 49/16 LIQUID 2-9/16 0 il 2-5/1 (4o 7/16 DIA HOLE JI TYP 4 PLCS M- 23-1/8 CL 16 FRONT VIEW 37-3/4 19-3/4 _l Pd 1 • 42-1/2 415/16 5-1/4 3-1(4 313(16 29-3/4 z 1• .o. • 6 • 1 15/16 2-1/4 3-11/16 3-11 4 3-1116 41 +16 5-1/4 1-15/16 2-1/4 3 11/16 33 1/2 To 6 HP Indoor & Outdoor Condensing Units SCROLL COMPRESSORS Unit Specifications Model MOZ005M6 Fig. ++ C Compressor ZSO6KAE Connections (ID) Receiver 9000 Full Lbs. 14 Fan(s) 2 Dimensio s Net Wt. Lbs. 198 Sound Data dBA Liquid 1/2 Suction 7/8 D (In.) 28-1/4 I VV (In.) 37-3/4 H (In.) 19-3/4 71 MOZ008M6 C ZSO7KAE 1/2 7/8 14 2 28-1/4 37-3/4 19-3/4 198 71 MOZ009M6 C ZSO8KAE 1/2 7/8 14 2 28-1/4 37-3/4 19-3/4 198 71 MOZ010M6 C ZSO9KAE 1/2 7/8 14 2 28-1/4 37-3/4 19-3/4 209 71 MOZ015M6 C ZS13KAE 1/2 7/8 14 2 28-1/4 37-3/4 19-3/4 209 71 MOZ020M6 C ZS15KAE 1/2 7/8 14 2 28-1/4 37-3/4 19-3/4 209 71 MOZ025M6 C ZS19KAE 1/2 7/8 14 2 28-1/4 37-3/4 19-3/4 218 73 MOZ030M6 D ZS21KAE 1/2 7/8 20 1 30-1/4 42-1/2 29-3/4 287 72 MOZ035M6 D ZS26KAE 1/2 7/8 20 1 30-1/4 42-1/2 29-3/4 290 74 MOZ045M6 D ZS29KAE 1/2 1-1/8 20 1 30-1/4 42-1/2 29-3/4 317 73 MOZO5OM6 D ZS33KAE 1/2 1-1/8 20 1 30-1/4 42-1/2 29-3/4 317 73 MOZ055M6 D ZS38K4E 1/2 1-1/8 20 1 30-1/4 42-1/2 29-3/4 317 74 MOZ060M6 D ZS45K43 1/2 1-1/8 20 1 30-1/4 42-1/2 29-3/4 317 76 MOZOO6L6 C ZFO3K4E 1/2 7/8 14 1 28-1/4 37-3/4 19-3/4 202 71 MOZOO8L6 C ZFO4K4E 1/2 7/8 14 1 28-1/4 37-3/4 19-3/4 201 71 MOZ010L6 C ZFO5K4E 1/2 7/8 14 1 28-1/4 37-3/4 19-3/4 202 71 MOZ020L6 C ZFO6K4E 1/2 7/8 14 2 28-1/4 37-3/4 19-3/4 209 71 MOZ022L6 C ZFO7K4E 1/2 7/8 14 1 28-1/4 37-3/4 19-3/4 203 71 MOZ025L6 C ZFO8K4E 1/2 7/8 14 2 28-1/4 37-3/4 19-3/4 218 73 MOZ030L6 C ZFO9K4E 1/2 7/8 14 2 28-1/4 37-3/4 19-3/4 218 71 MOZ035L6 C ZF11K4E 1/2 7/8 14 2 28-1/4 37-3/4 19-3/4 217 73 MOZ045L6 M0Z055L6 D ZF13K4E 1/2 1-1/8 20 1 30-1/4 42-1/2 29-3/4307 73 D ZF15K4E 1/2 1-1/8 201 C30-1/4 42-1/2 29-3/431T3 74 e MOZ060L6 D ZF18K4E 1/2 1-1/8 20 1 _ 30-1/4 42-1/2 29-3/4 317 76 NOTES: ++= See Dimensional Drawings for details. t = Estimated sound pressure values are 10 feet from the unit. For estimating sound pressure from the unit at different distances, deduct the following from the unit values: 20 feet, deduct 6 dBA for 40 feet, deduct 12 dBA for 80 feet, deduct 18 dBA. This data is typical of "free field" conditions for horizontal air cooled condensing units at the outlet of the discharge air. The actual sound measurements may vary depending on the condensing unit installation. Factors such as reflecting walls, background noise and mounting conditions may have a significant influence on this data. AWEF Values Medium/High Temperature Condensing Units -Cooler Application Model MOZ005M6 R404A/R507A 5.18 Indoor R407A/F 4.77 R407C 4.85 R448A/R449A 4.88 R404A/RSO7A 7.15 Outdoor; R407A/F 6.19 Beacon II R407C 5.89 R448A/R449A 7.17 MOZ008M6 5.33 4.95 4.95 4.20 7.60 6.62 6.27 6.77 MOZ009M6 5.55 5.08 5.22 3.77 8.02 6.92 6.79 5.42 MOZ010M6 5.99 5.92 5.54 5.43 8.32 7.85 7.11 7.29 MOZ015M6 5.93 5.55 5.42 5.27 8.63 7.90 7.52 7.50 MOZ020M6 5.95 5.35 5.42 5.21 8.04 7.91 7.72 768 MOZ025M6 5.11 5.28 5.26 5.02 7.64 8.01 7.65 7.65 MOZ030M6 6.56 6.31 6.44 6.16 9.04 8.55 8.36 8.45 MOZ035M6 6.49 6.17 6.45 5.98 9.15 8.63 8.58 8.42 MOZ045M6 6.46 6.06 6.36 6.18 9.08 8.59 8.73 8.81 MOZO5OM6 6.32 5.70 6.13 5.97 9.13 8.34 8.61 8.69 MOZ055M6 5.57 5.24 5.51 5.59 7.89 7.79 8.11 8.39 MOZ060M6 5.70 5.18 5.35 5.20 8.35 7.92 : 8.15 8.10 NOTES: These refrigeration systems are designed and certified for use in walk-in cooler applications. 26 m N m CA ,7 10'-2" G m O cn 0.1m X --1 C) O rrnn - n C7 m 0 Z n 7C = Z —i *7 t7 C, Z Z —I 0 4'-6" m -nz O m 70 - C7 x O rnZ r*i N C) m X1 73D. m (') O =z L_1 E m 1 11'-3" -i m 1O'-2" 4'-6" m N go I t'-3" Steven Vernete. < ri ,. n! v as t FW: InnovAsian Freezer Dec 11, 2017, 10:56:46 AM Trevor S Hearn am Trevor, Thanks again for the help with this project. Below is an email from the electrician and he had some questions I could not answer. I know we have a door light and two 4' LED lights. From: Eric Pierce[mailto:eric@hillelectriccorp.com] Sent: Tuesday, December 5, 2017 9:24 AM To: 'Robin Fawcett' <robin@joesimmons.com>; Steven Verne <Stevenv@ innovasiancuisine.com> Subject: RE: InnovAsian Freezer Hello Steve, I understand you will have a walk in cooler/ freezer for us to wire in. And from talking to Craig there is at least 1 conduit headed over to that area already. Here is what I need: Power requirements for indoor and outdoor units. Both cooler and freezer. P\r/95 - J01,67", Are the Tight fixtures being provided with the cooler?1-, Defrost requirements Is the defrost timer and fan interlock provided? Door heat/portal heat/heat tape for condensate drain? yes or no O JI Condensate pump? solenoid wiring? VtQr7 5 — And general location's If there is a drawing for the supplier that my clear up most of this. (A^ - Eric Pierce HILL az 'RIC .. Hill Electric Corporation City of Tukwila Department of Community Development February 08, 2018 TREVOR SUK 401 NE RAVENNA BLVD PMB 130 SEATTLE, WA 98115 RE: Correction Letter # 1 MECHANICAL Permit Application Number M18-0013 INNOVASIAN - 116 ANDOVER PARK E Dear TREVOR SUK, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - M DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient. (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) 1. Please provide the assembly details and show how the freezer shall be seismically anchored to the floor. 2. Rather than submitting the entire set of construction plans for the freezer installation, one sheet of the floor plan shall be sufficient showing where the freezer shall be located. Framing or installation and assembly details may be on an additional sheet. Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. .441 If you have any questions, I can be reached at (206)433-7165. Sincerely, Rachele Ripley Permit Technician File No. M18-0013 F7111-1 crifIthe.crnlor R,,,,Ie,,.,.,1 c,d,o 1111111 a T„L,.,;1,, W nb:.,,,r,,., 052 1.QQ a Al,, .,e 7n4"_e21_2,c7n . t: ,,.'1fl(,f21_a�s,cc PERMIT COORD COP? PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0013 DATE: 02/21/18 PROJECT NAME: INNOVASIAN SITE ADDRESS: 116 ANDOVER PARK E Original Plan Submittal Revision # before Permit Issued Revision # after Permit Issued X Response to Correction Letter # 1 DEPARTMENTS:ip\CC,, Ib J ? wo Building Division Fire Prevention Public Works ❑ Structural Planning Division ❑ ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 02/22/18 Structural Review Required REVIEWERc6 INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required DUE DATE: 03/22/18 ❑ Approved with Conditions ❑ ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWERc6 INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping 0 PW ❑ Staff Initials: 12/18/2013 OPERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0013 PROJECT NAME: INNOVASIAN SITE ADDRESS: 116 ANDOVER PARK E X Original Plan Submittal Response to Correction Letter # DATE: 01/24/18 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Corrl� Building Division Public Works A�M Pi1Mu Fire Prevention Structural Planning Division ❑ ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 01/25/18 Structural Review Required REVIEWERS INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required DUE DATE: 02/22/18 ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWERS INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: \\(‘ BIdgN--- Fire ❑ Ping ❑ PW ❑ Staff Initials:1 12/18/2013 liftq. City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov 40116, REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: M18-0013 0 Response to Incomplete Letter # S Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: INNOVASIAN Project Address: 116 ANDOVER PARK E Contact Person: �j '�pj . (tom Phone Number: Summary of Revision: ESP» ; '1 o Co /'{ c1. d•. I E REcL Ze;‘,) 4 -(tel— CS5zZ RECEIVED CI FY OF TUKWIL. FEB 16 2018 PERMIT CENTE Sheet Number(s): "Cloud" or highlight all areas of revision includin da o revision Received at the City of Tukwila Permit Center by: IJ �Vu Entered in TRAKiT on N I V A Permit Center (Brenda) Forms Permit Center Documents ( Word) Revision Submittal Form doc Revised .august 2015 POLAR BEAR MECHANICAL INI.) Home Espanol Contact Safety & Health Claims & Insurance Washington State Department of Labor & Industries Search L&I Page 1 of 2 A -Z Index help My L&I Workplace Rights Trades & Licensing POLAR BEAR MECHANICAL INC Owner or tradesperson Principals BELCHER, GARRY DEWAYNE, PRESIDENT Doing business as POLAR BEAR MECHANICAL INC WA UBI No. 603 145 986 401 NE RAVENNA BLVD 130 SEATTLE, WA 98115 425-967-5827 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no POLARBM891PC Effective — expiration 10/03/2011-10/03/2019 Bond Western Surety Co Bond account no. 62501547 $12,000.00 Received by L&I Effective date 10/09/2015 09/12/2015 Expiration date Until Canceled Bond history Insurance Endurance American Specialty I $1,000,000.00 Policy no. dci00549-00 Received by L&I Effective date 01/09/2018 01/08/2018 Expiration date 01/08/2019 Mid -Century Ins Co $1,000,000.00 Policy no. 605133486 Received by L&I Effective date 09/08/2017 09/12/2016 Expiration date Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603145986&LIC=POLARBM891 PC&SAW= 2/23/2018 r PROVIDE NON COMBUSTIBLE CONSTRUCTION AT HOOD ASSEMBLY NON COMBUSTIBLE CONSTRUCTION TO EXTEND 1'-6" PAST HOOD ASSEMBLY /8" GWB OVER 3.5 M.S. @ 24" O.C. DEMO EXISTING WOOD STUD CONSTRUCTION AS REQUIRED FIRE RESISTIVE CEILING TILE REQUIRE WITHIN 1'-6" OF HOOD COORDINATE WITH HOOD SUPPLIER L J �51 R T R N N N N 0 N 1 00' 20' Q./ 20' 20' 20' 20' NEW CONC PA ON GRADE FOR FREEZER MECH TES 109 OFFICE 110 ELEV 111 FOYER PAIR CONC AT RESHOLD AS QUIRED 112 STAIR L TES 113 HALL TES 114 OFFICE 115 ELEV 116 OFFICE 117 STO R 118 ELECT 119 SPRINK 108 -REEZE M N 0 4' 11 ,7 STORAGE RACKING NOT TO EXCEED 6' IN HEIGHT 106 WHSE 0 INFILL WALL WITH LIKE MATERIALS 120 KITCHEN 0 N) co TES 5 ma, GLASS/OPEN STOREFRONT WITH PASS THRU NEW FIXED GLASS IN ANOD STOREFRONT 121 CONF EXISTING GLAZING TO REMAIN 441 „ , PASS THRU SEE SGID NEW WALLS (TY1P) 105 LUNCH REF UPPER CABINET NEW P—LAM COUNTER 2'-10" A.F.F. -DISHWASHER EW DOUBLE SINK -INFILL WALL—WIT:1H LIKE MATERIALS O r 1 TES it 1 O :I N TES TES 102 RECEP 104 BATH 103 BATH FIRST FLOOR PLAN - 5,635 SQ. FT. NEW WOOD W AP AT EXISTING OPE ING TACTILE SIGNAGE (TYP) SCALE 1/8" .1 %0" 107 WHSE EXISTING FED EX TENANT NO WORK THIS SIDE (TYP) FED EX SPACE B 6,136 SQ. DEMO'D WALLS EXISTING WALLS NEW WALLS . I _DI II II LDG �rcl-titccts linardic design group . architects 6525 15TH AVE NW #200 seattle, wa 98117 (206)283-4764 NOT PUBLISHED. ALL RIGHTS RESERVED. THE ABOVE DRAWINGS AND SPECIFICATIONS AND IDEAS DESIGNS AND ARRANGEMENTS REPRESENT THEREBY ARE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT. NO PART THEREOF SHALL BE REPRODUCED. COPIED. ADAPTED. DISCLOSED OR DISTRIBUTED TO OTHERS. SOLD. PUBLISHED. OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPENSATION TO THE ARCHITECT. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS REGISTE D ARC IT =` TS IL FILE COPY Permit No. N1\`6/00«I Plan review approval is subject to errors and omissions. Approval of construction documents does net authorize the violation of any adopted Cod3 or ordinance. 1 cceipt of approved Field Copy and conditions is acknowledged: Ey: � 7'/' Date: 2-- a3 - r 8 City of Tukwila BUILDING DIVISION REVISIONS No changes shall ho made to the scope of work L�'itho�I:I_ prior approval of Tukwila Cui'c;incg. Division. NOTE: E. ,,v;c ,.: ‘viil raa quire a new plan submittal ' and may nude adnional plan rearw fees RECEIVED CITY OF TUKWILA FEB 162018 PERMIT CENTER CORRECTION LTf _ M1% 'Ootzi EDI L { DIC STATE OF WASHINGTON consultants: project title: PROPOSED PROJECT FOR: INNOVASIAN TENANT IMPROVEMENT TUKWILA, WA I SEPAF Par,r; 0 Mcctiat :cal ��'P:umb;ng LW"Gas Pipinrr 3IY1 sheet title: FLOOR PLANS PERMIT SUBMITTAL 5-19-2017 CONSTRUCTION SET 9-5-2017 SKYLIGHT REVISION 12-5-2017 CODE COMPLIANCE APe OVED FEB 2 2 21118 kl City of Tukwila BUILDING DI�✓ISIO�i no: revisions date: job no: draw: checked: date: 3-3-2017 sheet no: A-2.1