Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M18-0017 - BOEING #9-012 / IT SERVICE CENTER - ROOFTOP UNIT REPLACEMENT
BOEING #9-012 IT SERVICE CENTER 9725 E MARGINAL WAY S BLDG 9-012 EXPIRED 04/21/2019 M18-0017 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov MECHANICAL PERMIT 5624201032 Permit Number: M18-0017 9725 E MARGINAL WAY 5 BLDG 9-012 Issue Date: 2/12/2018 Permit Expires On: 8/11/2018 Project Name: BOEING #9-012 IT SERVICE CENTER Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: BOEING COMPANY THE PO BOX 3707 M/C 20-59 PROPERTY TAX DEPT, SEATTLE, WA, 98124 CONNIE HARDIN 4600 5 134 PL , SEATTLE, WA, 98168 HOLADAY PARKS INC 4600 5 134 PL , SEATTLE, WA, 98168 HOLADP1379NO Phone: (206) 250-4530 Phone: (206) 248-9700 Expiration Date: 9/3/2019 DESCRIPTION OF WORK: REPLACING 1 ROOFTOM UNIT AND ASSOCIATED DUCTWORK Valuation of Work: $30,000.00 Type of Work: REPLACEMENT Fuel type: Fees Collected: $615.18 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Permit Center Authorized Signature: rat I W Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws tegulating construction or the performance of work. I am authorized to sign and obtain this developme perrinit and a ee to the conditions attached to this permit. Signature: - cti„,(_._.: Date: / ( Z 741 Print Name: LINA 11, •-E ,_CL.1—C I c 1--- This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Alf construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. 11: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 12: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 13: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 14: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 15: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 16: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 17: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 18: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 19: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 20: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TulcwilaW A. gov Mechanical Permit No. A \ 64011 Project No. j Date Application Accepted: 1 ^1 Date Application Expires: " 1� O (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: Tenant Name; Cr `e Llil.eU/ Kin Co Assessor's Tax No.: 5 ZM if) `0q"(.1) PROPERTY OWNER `.. Name: Arlt; Name: l�QJl� Address: LI L ` 13 1 i -k, :' Address. 0 Q 7/ ).2 -Ay, frtie ,Al -i-.-_11)— J LLZ77 iUU State: l Q City: s 4:32-; ) pcJ CONTACT PERSON - person receiving all project communication Name: Arlt; ctrd�� Address: LI L ` 13 1 i -k, :' Cit 3- State: •�`}� Zit / . j l.w\!Ji Phone'I i�j _rig )ida) lN1f Faxes / 0 t�.262) Emai tiCi Pt' 1O L W S ..6:68-._ Suite Number: New Tenant: Floor: 0 Yes o MECHANICAL CONTRACTOR INFORMATION Company Name: {�.,� i _ pQ r f _. �. l►U L'(_�t� Addres44 /�v� [ ... lDl ,(J pi Ci State: U 74 Zi A7 Phone,/)66 z 9(5-./ fax: !nG fsvdtd Contr Reg No.:/3 wayp Date:e7,(1- Tukwila Business License No. lni1 9^c4— Valuation of project (contractor's bid price): $ 6.50. CP--07fS6 Describe the scope of work in detail: 4)-(A.JL-k) Use: Residential: New 0 Replacement Commercial: New 0 Replacement Fuel Type; Electric ❑ Gas ❑ Other: H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised l-416.docz Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Fumace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/ref ig/cooling system 47 dB(A) Air handling unit 1 <10,000 cfin 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 1 Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) -CSC' I IXl I 1,- 1 Boiler/Compressor Qty 0-3 hp/100,000 btu Residential, Nighttime 3-15 hp/500,000 btu Industrial 15-30 hp/1,000,000 btu 55 dB(A) 30-50 hp/1,750,000 btu 57 dB(A) 50+ hp/1,750,000 btu Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (lam -1 Opm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILD ; G 0 :� \ ' AUTH I ' l D AGENT: Signature: Date:r� Print Name: l' Y\ A r -e., 1 1 t r- Day Telephone: Mailing Address: 4 (pC) City State Zip H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: laniary 2016 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK I ACCOUNT r QUANTITY PAID M18-001, ., Address: 9725 E,MARGINAL WAY S'BLDG 0 2 Apn Credit Card Fee $17,92 Credit Card Fee R000.369.908.00.00 0.00 $17.92 MECHANICAL $574.29 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $426.28 PLAN CHECK FEE R000.322.102.00.00 0.00 $114.86 TECHNOLOGY FEE $22,97 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R13624 R000.322.900.04.00 0.00 $22.97 $615.18 Date Paid: Tuesday, January 30, 2018 Paid By: CONNIE HARDIN Pay Method: CREDIT CARD 08276G Printed: Tuesday, January 30, 2018 3:22 PM 1 of 1 CRWS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 »%/5 xv 7 Project:,,��,4,�1/6� �/A TypeInspection: of ` t 054,1- Address: 47 72 S £ /041746/i:9{- kM Date Called: Special Instructions: Date Wanted: 41/43 a:m: Requester: 17 ✓n Phone No: L7. 9V8— 4'.31).9 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 141/6€44.4 10/til arai-7-10ca(Z Inspector: Date: i_e2itis REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSP CTION NO. PERMIT NO.. CITY OF TUKWILA BUILDING DIVISION %1/8-a0i7 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Pro' ct: Type of Inspection: Address: 97?6- A" ,,X4t toe S' Date Called: Special Instructions: Date Wanted: / 43 `8 a.m. p.m. Requester: 7;.04 —, '2.¢y es, .acs Phone No: 207-„9X0-6,74/ EjApproved per applicable codes. EJ Corrections required prior to approval. COMMENTS: Meg gO1LT� Inspector: Date: n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Mt3-oo(-7 Pro'ect: �n 9-D1Z �� ins ection: T e of -et Ditc-t-Tusutailoo Address: ,� 772f E. M► C I vl � til Date a ed: Special Instructions: / 0 / Z Date Wanted: 3- -a."7-0-1,- z2- 20/$' p.m. Requester: /. -..144, Se,rvtccPhone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: �k' VC ,H -St) ' Tl of Inspector: Dater _z z -y6 r— REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 3/1/2019 City of Tukwila Department of Community Development CONNIE HARDIN 4600 S 134 PL SEATTLE, WA 98168 RE: Permit No. M18-0017 BOEING #9-012 IT SERVICE CENTER 9725 E MARGINAL WAY S BLDG 9-012 Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 4/21/2019. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 4/21/2019, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M18-0017 R,1 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Allan Ekberg, Mayor Department of Community Development - Jack Pace, Director July 12, 2018 Connie Hardin Holaday-Parks, Inc 4600 S 134th P1 Seattle, WA 98168 RE: Request for Extension #1 Permit Number M18-0017 Dear Ms. Hardin, This letter is in response to your written request for an extension to Permit M18-0017. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit through April 21, 2019. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, Rache RiP Y le Permit Technician File: Permit No. M18-0017 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov SMART Mechanical Solutions' INC WA: 4600 5134th PI, Seattle, WA 1108 1 206.248.9700 1 fax 206.248.8700 AK:1820 Marika, Fairbanks, AK 99709 1 907.452.7151 1 fax 907.452.3800 www.HOLADAYPARKS.com July 10, 2018 Jerry Hight Building Official City of Tukwila 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 RE: Permit M18-0017 Boeing 9-12 IT Service Center Extension request Dear Mr. Hight, RECEIVED CITY OF TUKWILA JUL 102018 PERMIT CENTER I'd like to request an extension to the above mechanical permit. Project is running a little longer than anticipated. The associated building permit has been extend to 10/15/18, so we shouldn't need it pushed out any later than that. Thank you. Connie Hardin/Permit Specialist Holaday Parks, Inc. 206-250-4530 connieh@holadayparks.com Request for Exjtensio- # L Current Expiration Date: \t\Q 1 Extension Request: , Approved for s days Denied (provide explanation) Signature "nitials MPERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M18-0017 DATE: 01/31/18 PROJECT NAME: BOEING #9-012 IT SERVICE CENTER SITE ADDRESS: 9725 E MARGINAL WAY S BLDG 9-012 X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: /FS x H -I8 Building Division ig Public Works W PWU 2°\I(6 Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 02/01/18 Not Applicable ❑ Structural Review Required (no approval/review required) REVIEWERGS INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03/01/18 Approved ❑ Approved with Conditions ❑ Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWERCS INITIALS: DATE: Permit Center Use Only CORRECTION LEITER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 HOLADAY PARKS INC Home Espanol Contact Safety & Health Claims & Insurance C:ilWashington State Department of Labor & Industries Search L&I Page 1 of 3 SEARCH A -Z Index Help My LLI Workplace Rights Trades & Licensing HOLADAY PARKS INC Owner or tradesperson Principals BECK, DAVID CARL, PRESIDENT CONNELL, DANIEL A, PRESIDENT GIRI, BIJIT, PRESIDENT PIZZEY, GRACE K, VICE PRESIDENT FREEL, JERRY LEE, VICE PRESIDENT PARKS, GERALD T JR, PRESIDENT (End: 08/12/2015) NAILON, JUNE ANNETTE, VICE PRESIDENT (End: 08/12/2015) O'CONNOR, BONNY K, SECRETARY (End: 08/12/2015) BECK, DAVID CLARENCE, TREASURER (End: 08/12/2015) VAN DER VEEN, ERIC M, VICE PRESIDENT (End: 08/14/2013) PIZZEY, GRACE KATHERINE, VICE PRESIDENT (End: 08/14/2013) VAN DER VEEN, JULIE ELIZABETH, MEMBER (End: 08/14/2013) CONNELL, DANIEL AARON, MEMBER (End: 08/14/2013) GIRI, BUIT, MEMBER (End: 08/14/2013) KIEL, RINALD HOWARD, MEMBER (End: 08/14/2013) WHITMYRE, CHRISTIAN, MEMBER (End: 08/14/2013) NELSON, MICHAEL, SECRETARY (End: 11/04/2010) PARKS, DAVID L, TREASURER (End: 11/04/2010) TALBOT, PAUL, TREASURER (End: 11/04/2010) Doing business as HOLADAY PARKS INC 4600 S 134TH PL SEATTLE, WA 98168 206-248-9700 KING County WA UBI No. Business type 578 004 089 Corporation Governing persons Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=578004089&LIC=HOLADPI379NO&SAW= 2/9/2018 HOLADAY PARKS INC ftor- DAVID BECK DAN CONNELL; JERRY FREEL; BIJIT GIRI; GRACE PIZZEY; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. HOLADPI379NO Effective — expiration 01/2111983— 09/03/2019 Bond LIBERTY MUTUAL INS CO Bond account no 23000452 $12,000.00 Received by L&I Effective date 08/23/2002 09/01/2002 Expiration date Until Canceled Insurance Charter Oak Fire Ins Co Policy no. DTCO1F465357C0F17 $1,000,000.00 Received by L&I Effective date 10/3112017 11/01/2017 Expiration date 11/01/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID Account is current. 177,231-00 Doing business as HOLADAY PARKS INC Estimated workers reported Quarter 4 of Year 2017 "Greater than 100 Workers" L&I account contact T4 / CASSANDRA SMITH (360)902-5632 - Email: SMCA235@lni.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Page 2 of 3 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=578004089&LIC=HOLADPI379N0&SAW= 2/9/2018 HOLADAY PARKS INC Contractors not allowed to bid + No debarments have been Issued against thin6ntractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 09/22/2016 Inspection no. 317940948 Location 1007 Stewart St Seattle, WA 98101 Inspection results date 08/09/2016 Inspection no. 317940177 Location 1011 Western Ave, Suite 1000 Seattle, WA 98104 Inspection results date 05/05/2016 Inspection no. 317940156 Location 4600 S 134th PI Tukwila, WA 98168 Inspection results date 06/11/2014 Inspection no. 317319382 Location 1011 Dexter Ave Seattle, WA 98102 Inspection results date 05/08/2014 Inspection no. 317278497 Location 2nd and 110th Ave Bellevue, WA 98004 Inspection results date 09/04/2012 Inspection no 316256841 Location 3003 W Casino Rd Everett, WA 98204 No violations No violations No violations No violations No violations Violations Page 3 of 3 Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=578004089&LIC=HOLADPI379NO&SAW= 2/9/2018 7-127 KING COUNTY AIRPORT OFFICE .CENTER (FM) PROJECT SITE FROM DOWNTOWN SEATTLE AIR MUSEUM BOEING FIELD 599 TUKWILA EAST MARGINAL WAY 99 CORPORATE PARK FROM KENT & AUBURN FROM SEATTLE—TACOMA AIRPORT IEVELOPvE\ NO SCALE 9 /Th SORT S AS HVC D \ AR AS v KW A,' O\S OF SFCT0\ WLLAFT -VAR TO A\ DARCFL \ v A G W\S IIS 23 \G CO„ BFR 562/2 AR — A VA D 3UILD1\G A»ESS: 9725 EAST vAKI\AL WAY SOUTH TU<WILA, WASHI\GTO\ PROJECT S ITE 3UIDI\G 9-12 LOCATIO\ NO SCALE A 0\ vso 98 \ORT , \Tv, WAS 0-0990 08 RA\D— \GTO\ —AST, CODF SVVARV 9-12 SUMMARY: LAND USE CODES BUILDING CODES OCCUPANCY GROUP CONSTRUCTION TYPE FLOOR AREAS: BUILDING HEIGHT: STORIES: FIRE PROTECTION: SEISMIC DESIGN CATEGORY: TUKWILA MUNICIPAL CODE CHAPTER 18, MIC/H ZONE, MAXIMUM HEIGHT 125 FT. 2015 IEBC, R0151 FC, 2015 IBC AS AMENDED, 2015 WASHINGTON STATE ENERGY CODE AND CITY OF TUKWILA TITLE 16; WAC 51-11 BARRIER FREE CODE AS ADOPTED OR AMENDED, AND COMPLIANCE WITH THE CITY OF TUKWILA ZONING CODES GROUP B TYPE II—B, SPRINKLERED (ORIGINALLY PERMITTED AS 3-1 HR WITH SPRINKLERS SUBSTITUTED FOR 1—HR CONSTRUCTION PER THE 1988 UBC) 9,381 SF 22' TO TOP OF PARAPET ONE FULLY SPRINKERED D SCOPE OF WORK: RECONFIGURE THE EXISTING DISHWASHING ROOM INTO AN OFFICE FOR THE 'IT' SERVICE CENTER. WORK INCLUDES INFILLING A WALL OPENING, ADDING ONE DOOR AND MOVING ANOTHER DOOR, RE—ROUTING HVAC DUCTS, REMOVING A LOW CEILING AREA, INSTALLING NEW LIGHTS, INSTALLING WORK STATIONS AND OTHER FURNITURE. T /KW LA BLAH SFT R V T BSA /-0009 FILE COPY Permit No. IIVW6 oon Pian review approval i3 subject to errors and omissions. Approval of construction documents docs not authorize the violation of any adopted code or ordinance. Receipt of approved Fie.: 4 • • d nditions jacknowledged: By: Date: 1--1 2-1 City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approve, of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may ine'ude additional Wan rsvf i fses APR 21 ei;: SEPARATE. PEUIT REQUME--., FOR: 0 kloct anical i' Electncat °E(Plumbing LieGas Piping City of Tukwila 13U1LDi^G DIVISION CODE COMPLIANCE APPROVED FEB 07 2018 Pr,) City of Tukwila IRCOuN STRUCTION JANUARY 04, 2018 RECEIVED CITY OF TUKWILA JAN 3 0 2018 PERMIT CENTER SITTS & HILL ENGINEERS, INC. CIVIL • STRUCTURAL • SURVEYING 4815 CENTER STREET 1 TACOMA, WA. 98409 PHONE: (253) 474-9449 1 FAX: (253) 474-9449 http://www.sitts-hill-engineers.com/ Project No.: 18027 Project Mgr.: BKL Proj. Engineer: JDB Proj. Drafter: JDK SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE IT SERVICE CENTER 34362 SITTS JDB 01.04.18 gia.Erzimrto ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN J. Kamla DATE 10.30.17 CHECKED B. Leslie 10.30.17 SUBTITLE COVER SHEET CURRENT REVISION 34362 SYMBOL DATE 01.04.18 APPROVED BY DEPT. DATE ENGINEER J. Baker CHECKED B. Leslie APPROVED 10.30.17 10.30.17 APPROVED TITLE ARCHITECTURAL IT SERVICE CENTER BUILDING 09-12 DEV. CENTER, WA SHEET AO JOB NO. 34362 COMP NO. DWG NO. 09-012—A 0 \DPX OF DRAW\CS INCLUDED IN SET NO. SHEET NO. DRAWING TITLE REV DATE DRAWING ARCHITECTUAL • 09-012—AO AO COVER SHEET -- 01,04.18 • 09-012—AI Al GENERAL ARCHITECTURAL NOTES — 01.04.18 • 09-012—IA10 IA10 FLOOR PLAN D 01.04.18 • 09-012—IAIOR IAIOR FLOOR PLAN —REMOVAL 01.04.18 — • 09-012—IA280 IA280 REFLECTED CEILING PLAN A 01,04.18 • 09-012—IA280R IA280R REFLECTED CEILING PLAN —REMOVAL — 01,04.18 • 09-012—RFAI60 RFA160 ROOF PLAN A 01.04.18 • 09-012—A500 A500 MISC. SECTIONS AND DETAILS — 01,04.18 vECHA\ICAC • 9-12—IMIOR IMIOR MAIN LEVEL PLAN — HVAC C 01.04.18 • 09-012—RFMIOR RFMIOR ROOF LEVEL PLAN — HVAC D 01 04.18 • 9-12—IM451R IM451R FOUNDATION PARTIAL PLAN — PIPING A 01,04.18 • 9-12—IM453R IM453R FIRST FLOOR PARTIAL PIPING PLAN B 01.04,18 • 9-12—IM5OIR IM501R BUILDING SECTION DETAILS A 01,04.18 • 9-12—IMIO IMIO MAIN LEVEL PLAN — HVAC C 01.04,18 • 9-12—RFMIO RFMIO ROOF LEVEL PLAN — HVAC D 01.04.18 • 9-12—IM260 1M260 MAIN LEVEL PLAN — FIRE SPRINKLERS B 01.04.18 • 9-12—IM450 1M450 FOUNDATION PARTIAL PLAN — PIPING A 01.04,18 • 9-12—IM452 1M452 FIRST FLOOR PARTIAL PIPING PLAN B 01.04.18 0 9-12—IM501 1M501 BUILDING SECTION DETAILS A 01.04.18 ELECTRICAL • 09-12—EI EI ELECTRICAL LEGEND — 01.04.18 • 09-012—E4R E4R ONE—LINE DIAGRAM C 01.04 18 • 9-12—IEIOR IEIOR LIGHTING PLAN B 01.04.18 • 9-12—IE60R IE60R 208Y/120 VOLT POWER C 01.04.18 • 9-12—E420R E420R COMMUNICATIONS PLAN A 01.04.18 • 9-12—IE502R 1E502R 120/208 V POWER PARTIAL PLAN D 01.04.18 • 09-012—FRE60R RFE6OR 120/208 VOLT POWER — ROOF PLAN B 01.04.18 t 9-012—E4 E4 ONE—LINE DIAGRAM C 01.04.18 • 9-12—IE10 1E10 LIGHTING PLAN B 01.04.18 • 9-12—IE60 1E60 120 VOLT POWER C 01.04.18 1 9-12—E420 E420 COMMUNICATIONS PLAN A 01.04.18 • 9-12—IE502 1E502 120/208 V POWER PARTIAL PLAN D 01.04.18 • 09-012—FRE60 RFE60 120/208 VOLT POWER — ROOF PLAN B 01.04.18 • 9-12—E500 E500 FIXTURE SCHEDULE AND DETAILS B 01.04.18 —,—. .Jr -.,Tr rno CODE COMPLIANCE APPROVED FEB 07 2018 Pr,) City of Tukwila IRCOuN STRUCTION JANUARY 04, 2018 RECEIVED CITY OF TUKWILA JAN 3 0 2018 PERMIT CENTER SITTS & HILL ENGINEERS, INC. CIVIL • STRUCTURAL • SURVEYING 4815 CENTER STREET 1 TACOMA, WA. 98409 PHONE: (253) 474-9449 1 FAX: (253) 474-9449 http://www.sitts-hill-engineers.com/ Project No.: 18027 Project Mgr.: BKL Proj. Engineer: JDB Proj. Drafter: JDK SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE IT SERVICE CENTER 34362 SITTS JDB 01.04.18 gia.Erzimrto ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN J. Kamla DATE 10.30.17 CHECKED B. Leslie 10.30.17 SUBTITLE COVER SHEET CURRENT REVISION 34362 SYMBOL DATE 01.04.18 APPROVED BY DEPT. DATE ENGINEER J. Baker CHECKED B. Leslie APPROVED 10.30.17 10.30.17 APPROVED TITLE ARCHITECTURAL IT SERVICE CENTER BUILDING 09-12 DEV. CENTER, WA SHEET AO JOB NO. 34362 COMP NO. DWG NO. 09-012—A 0 RG 30/20 1800 CFM P. OF 3'' O RG 30/20 1325 CFM TYP OF o2 1M1OR 1M5 24/12 TYP. OF 5 32/12 TYP. OF 8 48/16 SG 32/12 1360 CFM TYP. OF 5 24x24 ACCESS PANELS SG 32/12 1000 CFM TYP OF 3 /6" ID FLUE UP 14/8 14/14 UP 12/12 EXHAUST UP FIA2A 16/16 '-,\ EXHAUST UP 12/6'Tr 4 EG 12/12 175 CFM TYP OF 4 EG 12/12 150 CFM 1M10 M502 PG13 'rola :l [��I 111 24/12 16/10 SD 15 820 CFM TYP OF 5 —� SD 15 610 CFM TYP OF 4 D 15 �00 C TYP OF 3 26/12 18/10 TYP. 2 SD6 100 CFM FIG3A EG 12/12 100 CFM 12/12 UP TO ROOF JACK 12/12 UP TO ROOF JACK REVISION FIB3 TG 24/24 FCIC3 350 CFM �7 TYP OF 2 120/24 3550 CFM. 1/2" SQUARE MECH 16 GAGE GALVANIZED MESH SCREEN BY APPROVED DATE SYM A 1M10 1M500 SD 15 1000 CFM TYP OF 2 PROVIDE SOUND ATTENUATING SILENCERS AS PER SPEC. SECTION 15880 AND SCHEDULES. TYPICAL FOR ALL ROOFTOP AIR HANDLING/CONDITIONING UNITS REVISION BY REMOVAL APPROVED DATE CONVERSION FROM MYLAR TO CAD REPLACE ACRG2A 3602 REPLACE ACRC2C 4851 ccSI HARR HARR 12.10.00 04/01/09 06/18/09 IT SERVICE CENTER 34362 FSi AWL 01.04.18 1 M 10 1M501 PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED Q� BOE/NGm cr— 01.04.18 3N:NSD ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE EIV. OVAL \OTES 4 LEGE\D 24/12 N C)1 UP [VD BDD } BDD \ 11 SG _ 30/12 1030 CFM O SD15 750 CFM RG36/20 11365 CFM EG 12/10 200 CFM i } zo iz 500 CFM f� TRANSFER AIR GRILLES AND r I DUCT RECTANGULAR DUCT. FIRST NO. INDICATES SIZE FOR SIDE SHOWN SUPPLY AIR DUCT, ELBOW, PLAN UP AND DOWN RETURN AIR DUCT, ELBOW, PLAN UP AND DOWN EXHAUST AIR DUCT, ELBOW, PLAN UP AND DOWN ROUND DUCT, ELBOW, PLAN UP AND DOWN DUCT OFFSET UP OR DN. VOLUME DAMPER BACKDRAFT DAMPER TEMPERATURE SENSOR, DUCT MOUNTED ELBOW WITH TURNING VANES FLEXIBLE DUCT CONNECTION SIDE WALL SUPPLY AIR GRILLE. FACE DIMENSIONS, CFM SHOWN SUPPLY AIR DIFFUSER. 4—WAY THROW UNLESS NOTED BY AIR FLOW ARROWS NECK SIZE CFM SHOWN RETURN AIR GRILLE. FACE DIMENSIONS, CFM EXHAUST AIR GRILLE FACE DIMENSIONS, CFM SOUND ATTENTUATOR LOUVER (BY G.C.) SEE ARCH DWGS. CFM SHOWN. L UNIT HEATER, HORIZONTAL TEMPERATURE TRANSMITTER THERMOSTAT A33EVIATIO\S AC AD AH BDD CFM 0 EC EF EG FC GC ID MC MIN RP SD SG TYP TG UH RG REMOVE ALL SUPPLY DUCTWORK AND SUPPORTS. REMOVE ALL EXHAUST DUCTWORK AND SUPPORT. PATCH CEILING TILE AS NECESSARY. FSi consulting engineers Seattle, Washington Solutions & Service DRAWN I. SIMKIN DATE CHECKED SUBTITLE ISSUED FOR CONSTRUCTION JANUARY 04, 2018 MAIN LEVEL PLAN - HVAC ROOFTOP AIR CONDITIONING UNIT ACCESS DOOR ROOFTOP MAKE-UP AIR HANDLING UNIT BACKDRAFT DAMPER CUBIC FEET PER MINUTE DIAMETER ELECTRICAL CONTRACTOR EXHAUST FAN EXHAUST GRILLE: TITUS CORE 4 FAN COIL UNIT GENERAL CONTRACTOR INSIDE DIAMETER MECHANICAL CONTRACTOR MINIMUM RADIANT PANEL SUPPLY AIR DIFFUSER: TITUS TMS SUPPLY AIR GRILLE: TITUS 272FL TYPICAL TRANSFER AIR GRILLE: TITUS 50F UNIT HEATER RETURN GRILLE: TITUS 5OF RECEIVED CITY OF TUK` ILA REVIEWED FOR CODE COMPLIANCE APPROVED FEB 0 7 2018 City of Tukwila BUILDING DIVISION JAN 3 0 2018 PERMIT CENTER CURRENT REVISION 34362 SYMBOL DATE 01.04.18 ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER IT SERVICE CENTER BUILDING 9-12 COL. A—H/1-3 SHEET IMIOR JOB NO. COMP NO. DWG NO. D.C. 9-12-1M1OR cA) OCF LEVEL PLA\ - HVAC SCALE: 1/8" = 1'-0" REMOVAL PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED 1 " GAS RELIEF VENT 6" ID FLUE FSi consulting engineers Seattle, Washington Solutions 8c Service LEGEND GE\EAL \OTES 8.5 TON ROOF A/C, MEDIUM CAPACITY GAS HEAT, 460/60/3, ECONOMIZER, DRY BULB 0-100%, POWER EXHAUST, TRANE MODEL YSC102A4. 15 TON ROOF A/C, 203MBH GAS HEAT, 460/60/3, ECONOMIZER, DRY BULB 0-100%, POWER EXHAUST, TRANE MODEL YCD180B4L. 8.5 TON ROOF A/C, MEDIUM CAPACITY GAS HEAT, 460/60/3, ECONOMIZER, DRY BULB 0-100%, POWER EXHAUST, TRANE MODEL YSC102F. EFEH\CE D�AWI\GS EVOVAL \OTES REMOVE EF, CURB AND EXHAUST DUCTWORK THROUGH ROOF. PATCH ROOF OPENING TO MATCH EXISTING. SEE ARCHITECTURAL SHEETS. REMOVE AC UNIT, CURB AND SUPPLY/RETURN DUCTING THROUGH ROOF. CAP AND PROTECT NATURAL GAS PIPING FOR RECONNECTION. ISSUED FOR CONSTRUCTION JANUARY 04, 2018 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 0 7 2018 City of Tukwila DING DIVE3,N RECEIVED / RFM10 fl i'Y OF T U K W I L JAN 302018 PERMIT CENTER 0 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE CONVERSION FROM MYLAR TO CAD A B C D REPLACE ACRG2A 3602 REPLACE ACRC2C 4851 REPLACE ACRC2B Y303776 IT SERVICE CENTER 34362 COSI HARR HARR MAINT FSi 12.10.00 04/01/09 06/18/09 12.20.13 AWL 01.04.18 BE/NG° ACCEPTABILITY o'— 01.04.18 MIND THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN I. SIMKIN DATE CHECKED SUBTITLE ROOF LEVEL PLAN - HVAC CURRENT REVISION 34362 SYMBOL D DATE 01.04.18 ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER IT SERVICE CENTER BUILDING 9-12 COL. A—H/1-3 D.C. SHEET RFM10R JOB NO. COMP NO. DWG NO. 9-12—RFM1OR A 0 a a 0 0 0 FSP 55* —1 C )f FSP 49*� 2" 1/2" 1/2" 1'2" TRAP PRIMER TYPICAL 2" r SAN 0 An 2 SAN 4" SEE CIVIL SITE UTILITY PLAN FOR CONTINUATION 1 1/2" 2' 4" 3L l i SAN SAN sAN —' PARTIAL FL0N PLA\ SCALE: 1/4" = 1'-0" REMOVAL SAN SAN PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED " \2" SAN " If 1 1/2" 4„ SAN 1 • FSi consulting engineers Seattle, Washington Solutions & Service LEGE\J I CO CLEAN OUT, EXPOSED FCO CLEAN OUT, FLOOR I Wco CLEAN OUT, WALL COLD WATER, DOMESTIC HOT WATER, DOMESTIC HOT WATER, CIRCULATING DOMESTIC NATURAL GAS INDIRECT DRAIN SANITARY WASTE VENT —+p —+-o T ELBOW UP, DN., SIDE '0' TEE UP, DN., SIDE CAP, SCREWED OR SOLDER CONCENTRIC REDUCER UNION ( BALL VALVE GATE VALVE c®v GLOBE VALVE, N.C. • GAS PLUG VALVE BALANCING VALVE CHECK VALVE HB NON–FREEZE HOSE BIB PRESSURE REDUCING VALVE TEMPERATURE AND PRESSURE RELIEF VALVE SOLENOID VALVE FLEXIBLE. CONNECTOR PRESSURE GAGE 4 STEM, THERMOMETER (ID PIPE MOUNTED CIRCULATION PUMP STRAINER WITH BLOW–OFF GLOBE VALVE BACKFLOW PREVENTER .111 OVA \A„ E1OVAL \OYES A REMOVE PIPING 6" BELOW FLOOR AND CAP AND ABANDON REMAINING PIPING IN PLACE. GROUT PATCH THE FLOOR TO MATCH EXISTING. SEE ARCHITECTURAL SHEETS. ABANDON PIPING IN PLACE. REMOVE FLOOR DRAIN OR FLOOR SINK AND CAP WASTE PIPE 6" BELOW FINISHED FLOOR AND CAP 1/2" TRAP PRIME PIPE. GROUT PATCH THE FLOOR TO MATCH EXISTING. SEE 1 M453R. REVIEWED FOR CODE COMPLIANCE FEB 0 7 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 3 0 2018 ISSUED FOR CONSTRUCTION PERMIT CENTER KEY PLAN 4 JANUARY 04, 2018 SCALE: NONE SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE CONVERSION FROM MYLAR TO CAD A IT SERVICE CENTER 34362 COSI FSi 12.10.00 AWL 01.04.18 fftE/iVC° d -- WBM ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN I. SIMKIN DATE CHECKED SUBTITLE FOUNDATION PARTIAL PLAN - PIPING CURRENT REVISION SYMBOL 34362 A DATE 01.04.18 ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER IT SERVICE CENTER BUILDING 9-12 COL. A–D/2-3 D.0 SHEET 1M451R JOB NO. COMP NO. DWG NO. 9-12-1M451R HB 3/4" MI ING VALVE FSP55* 1/2" C 1 1/2" *FSP75 3/4" *FSP75 3/4" *FSP75 1 1/2" *FSP75 3/4" *FSP75 3/4" *FSP75 1 1/2" *FSP75 *FSP60 1 X. *FSP58 *FSP58 *FSP49 EVERPURE FILTER QL3 HEAD, 4CB5-S GREASE INTERCEPTOR 2 6 EWC, ELKA EMABFTL8C /„ 2„ 4 G HWC cw 1M453 1M110 MIXING V VE VALVE 0 cw v G v FSP78* v v 2)/ n v v FSP51* FSP53* v FFD P v v FCO �-- 1 1 /2" G G HWC HWC HW C51 A1-40 WC -1 ?NC2 1 WC -2 FD , 1 1/2" PARTIAL FLOO PLA\ SCALE: 1/4" = 1'-0" REMOVAL HB cw HW FS HW v v v v 3" V ' v --I L,J w (1) r-2 1/2" 3 G"/1 1/2„ G G G HWC w FFD HW 2 1/2" PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED 2" 1/2"*FSP50 2" *FSP48 1/2"*FSP46 3" 1/2"*FSP47 1 1/2" 1/2" 1 /2"*FSP45 / 3" *FSP76 3 1/2" 1 1 /2"*FSP80 1/2" 1/2" *FSP44 OVAL \OTES: LEGE\ CO FCO wco cw cw HW HW CLEAN OUT, EXPOSED CLEAN OUT, FLOOR CLEAN OUT, WALL COLD WATER, DOMESTIC HOT WATER, DOMESTIC —HWC HWC— HOT WATER, CIRCULATING G G NATURAL GAS ID ID INDIRECT DRAIN SAN SANITARY WASTE 1 BFP GE VENT ELBOW UP, DN., SIDE TEE UP, DN., SIDE CAP, SCREWED OR SOLDER CONCENTRIC REDUCER UNION STRAINER WITH BLOW—OFF GLOBE VALVE BALL VALVE GATE VALVE GLOBE VALVE, N.C. GAS PLUG VALVE BALANCING VALVE CHECK VALVE HB NON—FREEZE HOSE BIB PRESSURE REDUCING VALVE BACKFLOW PREVENTER VALVE TEMPERATURE AND PRESSURE RELIEF VALVE FLEXIBLE CONNECTOR PRESSURE GAGE STEM THERMOMETER PIPE MOUNTED CIRCULATION PUMP SOLENOID VALVE \HAL \OTES REMOVE DISHWASHER AND BOOSTER HEATERS. REMOVE MOP SINK AND PROTECT AND SAVE FOR RELOCATION WITHIN BUILDING 9-12. SEE MECHANICAL SHEET [1 M452] FOR RELOCATION LOCATION. REMOVE SINK. REMOVE FLOOR SINK. REMOVE FLOOR DRAIN. REFER TO THE FOOD SERVICE EQUIPMENT LAYOUT PLANS AND SCHEDULES FOR EXACT PLUMBING ROUGH—IN DIMENSIONS AND EQUIP— MENT CONNECTION SIZES. REFER TO FOOD SERVICE SCHEDULES FOR EQUIPMENT DESIGNATIONS. *FIXTURE FURNISHED & INSTALLED BY G.C. PIPING CONNECTION AND ROUGH—IN BY M.C. REFER TO THE ATTACHED ADDENDA SKETCH AE 3.1 FOR ROOF PENETRATION DETAIL. TYPICAL ALL ROOF PIPING PENETRATIONS. COORDINATE AND ARRANGE PIPING AT BASE OF WALL TO AVOID CONFLICT WITH BRACE FRAME STRUCTURE. REVIEWED FOR CODE COMPLIANCE APPROVED FEB 0 7 2018 ity of Tukwila LDING DIVISION FSi consulting engineers Seattle, Washington Solutions & Service ISSUED FOR CONSTRUCTION JANUARY 04, 2018 RECEIVED ITV OF TUKWIL JAN 3 0 2018 PERMIT CENTER SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A B CONVERSION FROM MYLAR TO CAD DESIGN INSTALL DRINKING FOUNTAIN IT SERVICE CENTER 9594871 34362 COSI M.WONG 12.10.00 FSi MW FOR RWS AWL 10.22.09 01.04.18 Q� BOE/A/G �Y- SMB CR DD ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN I. SIMKIN DATE CHECKED SUBTITLE FIRST FLOOR PARTIAL PIPING PLAN CURRENT REVISION SYMBOL 34362 3 DATE 01.04.18 ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER IT SERVICE CENTER BUILDING 9-12 COL. A—D/2-3 D.C. SHEET 1M453R JOB NO. COMP NO. DWG NO. 9-12-1M45 3R SYM FIRE DEPARTMENT CONNECTION \ .411 i SEE TYPICAL AHU VIBRATION ISOLATION CURB DETAIL ON THIS DWG. SEE SPEC. SECTION 15240 COORDINATE THE EXACT LOCATIONS FOR DUCT—SMOKE DETECTORS (BY E.C.) SO AS TO BE FULLY ACCESSIBLE PROVIDE NECESSARY ACCESS PANEL TYPICAL FOR ALL OF THE ROOFTOP AIR HANDLING UNITS. -44=6„ wramprAtiv--77" • • ;$'' f 1 \/\/fu REVISION E SECTIO\ c SCALE: 1/4"--1'-0" rx1IWL garr AMSDPIX. min dew11. .1rir' trtmirgArivir 71111 BY APPROVED DATE SYM REVISION BY iM501LM10 ROOF TOP UNIT CURB ACOUSTICAL BARRIER SEISMIC SPRING VIBRATION ISOLATION CURB. (SPEC 15240) FLEX DUCT CONN AROUND DUCT. TYP. 2"x2"x1/8" ANGLE IRON AROUND DUCT REMOVAL APPROVED DATE CONVERSION FROM MYLAR TO CAD A IT SERVICE CENTER 34362 COSI FSi 12.10.00 AWL 01.04.18 18 GAGE DUCT TYP. 2"/3LB INSULATION TYP. HAT CHANNEL SUPPORT. TYP. PERFORATED METAL LINER. TYP. SOUND ATTENUATOR (SEE SPEC. 15880) L L L. LL n LL LL Lam___ FLEX. DUCT CONN. TYP. LEVELING CURB BY G.C. ROOF Lu_ DETAIL -GOOF U\ITS-TYPICAL SCALE: N.T.S. PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED Q�BOE/NG' cY— ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE 01.04.18 SIGNED L 5 �11 1M501I1M10 FSi consulting engineers Seattle, Washington Solutions 8c Service DRAWN I. SIMKIN DATE CHECKED SUBTITLE A vOVAL \OYES MODIFY SPRINKLER HEADS AND PIPING TO ACCOMMODATE MODIFIED CEILING HEIGHT. RECONNECT HEADS TO SUPPLY PIPING TO MAINTAIN APPROVED FIRE COVERAGE. APR 23. ; ISSUED FOR CONSTRUCTION JANUARY 04, 2018 BUILDING SECTION DETAILS REVIEWED FOR CODE COMPLIANCE APPROVED FEB 0 7 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 3 0 2018 PERMIT CENTER CURRENT REVISION SYMBOL 34362 A DATE 01.04.18 ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER IT SERVICE CENTER BUILDING 9-12 COL. 1-3 D.C. SHEET IM5OIR JOB NO. COMP NO. DWG NO. 9-12-1 M501 R FIA2A pf i4 RG 30 20 1800 CFM P. OF 3 • • RG 30/20 1325 CFM TYP OF 2 ►1 LJ 1M10 1M5 24/12 TYP. OF 5 32/12 TYP. OF 8 SG 32/1 1360 CF TYP. OF \dIFA 24x24 ACCESS PANELS SG 32/12 1000 CFM TYP OF 3 ► 48/16 -- I 12/12 ♦ — 32/12' EXHAUST 6" ID FLUE UP —24/24 36/14 • • • • `EG 12/12 150 CFM L • 12/6 TYP 4 14/14 24/8 r=.nmIt immi ragNi�uit �3�_ ;16/10 24/12 30/12 40/14 EXHAUST UP 16/16 EG 12/12 175 CFM TYP OF 4 1M10 M502 PGI 3 24/12 16/10 SD 15 820 CFM TYP OF 5 SD 15 610 CFM TYP OF 4. L1 SD 15 1000 CFM TYP OF 3 26/12 18/10 TYP. 2 SD6 100 CFM FIGA EG 12/12 100 CFM 12/12 UP TO ROOF JACK 12/12 UP TO ROOF JACK RPIB3 TG 24/24 FCIC3 350 CFM TYP OF 2 120/24 3550 CFM. 1/2 SQUARE MECH 16 GAGE GALVANIZED MESH SCREEN SD 15 1000 CFM TYP OF 2 PROVIDE SOUND ATTENUATING SILENCERS AS PER SPEC. SECTION 15880 AND SCHEDULES. TYPICAL FOR ALL ROOFTOP AIR HANDLING/CONDITIONING UNITS 1M10 1M500 NAI\ LEVEL PLA\ - HVAC SCALE: 1/8" = 1'-0" 1M10 1M500 PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED FSi consulting engineers Seattle, Washington Solutions & Service GE\ HAL \OTES SUPPLY DIFFUSER, TITUS TMS, 8"0 NECK, 24x24 FULL FACE LAY—IN MODULE, #26 WHITE FINISH, TYP. 4. RETURN GRILLE, TITUS 50F, 24x12, #26 WHITE FINISH, LAY—IN PANEL MOUNT. LEGE\D N 24/12 1\1 } } } UP BDD SG 30/12 1030 CFM i S f O SD15 750 CFM RG36/20 1365 CFM EG 12/10 200 CFM } a:141,2_ 500 CFM C ti Hoi RECTANGULAR DUCT. FIRST NO. INDICATES SIZE FOR SIDE SHOWN SUPPLY AIR DUCT, ELBOW, PLAN UP AND DOWN RETURN AIR DUCT, ELBOW, PLAN UP AND DOWN EXHAUST AIR DUCT, ELBOW, PLAN UP AND DOWN ROUND DUCT, ELBOW, PLAN UP AND DOWN DUCT OFFSET UP OR DN. VOLUME DAMPER BACKDRAFT DAMPER TEMPERATURE SENSOR, DUCT MOUNTED ELBOW WITH TURNING VANES FLEXIBLE DUCT CONNECTION SIDE WALL SUPPLY AIR GRILLE. FACE DIMENSIONS, CFM SHOWN SUPPLY AIR DIFFUSER. 4—WAY THROW UNLESS NOTED BY AIR FLOW ARROWS NECK SIZE CFM SHOWN RETURN AIR GRILLE. FACE DIMENSIONS, CFM EXHAUST AIR GRILLE FACE DIMENSIONS, CFM SOUND ATTENTUATOR LOUVER (BY G.C.) SEE ARCH DWGS. CFM SHOWN. TRANSFER AIR GRILLES AND DUCT UNIT HEATER, HORIZONTAL TEMPERATURE TRANSMITTER THERMOSTAT A33EVIATIO\S AC AD AH BDD CFM 0 EC EF EG FC GC ID MC MIN RP SD SG TYP TG UH RG ROOFTOP AIR CONDITIONING UNIT ACCESS DOOR ROOFTOP MAKE—UP AIR HANDLING UNIT BACKDRAFT DAMPER CUBIC FEET PER MINUTE DIAMETER ELECTRICAL CONTRACTOR EXHAUST FAN EXHAUST GRILLE: TITUS CORE 4 FAN COIL UNIT GENERAL CONTRACTOR INSIDE DIAMETER MECHANICAL CONTRACTOR MINIMUM RADIANT PANEL SUPPLY AIR DIFFUSER: TITUS TMS SUPPLY AIR GRILLE: TITUS 272FL TYPICAL TRANSFER AIR GRILLE: TITUS 5OF UNIT HEATER RETURN GRILLE: TITUS 50F C3\SRUCTI \ \OTES INSULATE ALL SUPPLY AND RETURN DUCTING TO MINIMUM R-6 AND SEAL DUCTING PER THE 2015—WASHINGTON STATE ENERGY CODE. CODE COMPLIANCE APPROVED FEB 0 7 2018 City of Tukwila BUILDING DIVISION v ISSUED FOR CONSTRUCTION JANUARY 04, 2018 CITY OF TUKWILA JAN 3 0 2018 PERMIT CENTER SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A CONVERSION FROM MYLAR TO CAD REPLACE ACRG2A REPLACE ACRC2C 3602 4851 CCSI HARR HARR 12.10.00 04/01/09 06/18/09 IT SERVICE CENTER 34362 FSi AWL 01.04.18 LWIW” ® MAAS ECM THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRNAM SIMKIN DATE SUBTITLE CHECKED MAIN LEVEL PLAN - HVAC CURRENT REVISION 34362 SYMBOL DATE 01.04.18 ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER IT SERVICE CENTER BUILDING 9-12 D.C. SHEET 1 M 1 0 JOB NO. COMP NO. DWG NO. ' t , . moi' I 12/12 ♦ — 32/12' EXHAUST 6" ID FLUE UP —24/24 36/14 • • • • `EG 12/12 150 CFM L • 12/6 TYP 4 14/14 24/8 r=.nmIt immi ragNi�uit �3�_ ;16/10 24/12 30/12 40/14 EXHAUST UP 16/16 EG 12/12 175 CFM TYP OF 4 1M10 M502 PGI 3 24/12 16/10 SD 15 820 CFM TYP OF 5 SD 15 610 CFM TYP OF 4. L1 SD 15 1000 CFM TYP OF 3 26/12 18/10 TYP. 2 SD6 100 CFM FIGA EG 12/12 100 CFM 12/12 UP TO ROOF JACK 12/12 UP TO ROOF JACK RPIB3 TG 24/24 FCIC3 350 CFM TYP OF 2 120/24 3550 CFM. 1/2 SQUARE MECH 16 GAGE GALVANIZED MESH SCREEN SD 15 1000 CFM TYP OF 2 PROVIDE SOUND ATTENUATING SILENCERS AS PER SPEC. SECTION 15880 AND SCHEDULES. TYPICAL FOR ALL ROOFTOP AIR HANDLING/CONDITIONING UNITS 1M10 1M500 NAI\ LEVEL PLA\ - HVAC SCALE: 1/8" = 1'-0" 1M10 1M500 PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED FSi consulting engineers Seattle, Washington Solutions & Service GE\ HAL \OTES SUPPLY DIFFUSER, TITUS TMS, 8"0 NECK, 24x24 FULL FACE LAY—IN MODULE, #26 WHITE FINISH, TYP. 4. RETURN GRILLE, TITUS 50F, 24x12, #26 WHITE FINISH, LAY—IN PANEL MOUNT. LEGE\D N 24/12 1\1 } } } UP BDD SG 30/12 1030 CFM i S f O SD15 750 CFM RG36/20 1365 CFM EG 12/10 200 CFM } a:141,2_ 500 CFM C ti Hoi RECTANGULAR DUCT. FIRST NO. INDICATES SIZE FOR SIDE SHOWN SUPPLY AIR DUCT, ELBOW, PLAN UP AND DOWN RETURN AIR DUCT, ELBOW, PLAN UP AND DOWN EXHAUST AIR DUCT, ELBOW, PLAN UP AND DOWN ROUND DUCT, ELBOW, PLAN UP AND DOWN DUCT OFFSET UP OR DN. VOLUME DAMPER BACKDRAFT DAMPER TEMPERATURE SENSOR, DUCT MOUNTED ELBOW WITH TURNING VANES FLEXIBLE DUCT CONNECTION SIDE WALL SUPPLY AIR GRILLE. FACE DIMENSIONS, CFM SHOWN SUPPLY AIR DIFFUSER. 4—WAY THROW UNLESS NOTED BY AIR FLOW ARROWS NECK SIZE CFM SHOWN RETURN AIR GRILLE. FACE DIMENSIONS, CFM EXHAUST AIR GRILLE FACE DIMENSIONS, CFM SOUND ATTENTUATOR LOUVER (BY G.C.) SEE ARCH DWGS. CFM SHOWN. TRANSFER AIR GRILLES AND DUCT UNIT HEATER, HORIZONTAL TEMPERATURE TRANSMITTER THERMOSTAT A33EVIATIO\S AC AD AH BDD CFM 0 EC EF EG FC GC ID MC MIN RP SD SG TYP TG UH RG ROOFTOP AIR CONDITIONING UNIT ACCESS DOOR ROOFTOP MAKE—UP AIR HANDLING UNIT BACKDRAFT DAMPER CUBIC FEET PER MINUTE DIAMETER ELECTRICAL CONTRACTOR EXHAUST FAN EXHAUST GRILLE: TITUS CORE 4 FAN COIL UNIT GENERAL CONTRACTOR INSIDE DIAMETER MECHANICAL CONTRACTOR MINIMUM RADIANT PANEL SUPPLY AIR DIFFUSER: TITUS TMS SUPPLY AIR GRILLE: TITUS 272FL TYPICAL TRANSFER AIR GRILLE: TITUS 5OF UNIT HEATER RETURN GRILLE: TITUS 50F C3\SRUCTI \ \OTES INSULATE ALL SUPPLY AND RETURN DUCTING TO MINIMUM R-6 AND SEAL DUCTING PER THE 2015—WASHINGTON STATE ENERGY CODE. CODE COMPLIANCE APPROVED FEB 0 7 2018 City of Tukwila BUILDING DIVISION v ISSUED FOR CONSTRUCTION JANUARY 04, 2018 CITY OF TUKWILA JAN 3 0 2018 PERMIT CENTER SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A CONVERSION FROM MYLAR TO CAD REPLACE ACRG2A REPLACE ACRC2C 3602 4851 CCSI HARR HARR 12.10.00 04/01/09 06/18/09 IT SERVICE CENTER 34362 FSi AWL 01.04.18 LWIW” ® MAAS ECM THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRNAM SIMKIN DATE SUBTITLE CHECKED MAIN LEVEL PLAN - HVAC CURRENT REVISION 34362 SYMBOL DATE 01.04.18 ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER IT SERVICE CENTER BUILDING 9-12 D.C. SHEET 1 M 1 0 JOB NO. COMP NO. DWG NO. ED) —1 " GAS RELIEF VENT 6" ID FLUE GOOF LEVEL PLA\ - HVAC SCALE: 1/8" = 1'-0" PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A B C D CONVERSION FROM MYLAR TO CAD REPLACE ACRG2A REPLACE ACRC2C REPLACE ACRC2B IT SERVICE CENTER 3602 4851 Y303776 34362 CCSI HARR 12.10.00 04/01/09 HARR MAI NT FSi 06/18/09 12.20.13 Q� BOE/NG' 6' - ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DATE co ST UCTION OTES FIELD VERIFY ROOF SLOPE AND PROVIDE CUSTOM ROOF CURB TO MATCH ROOF SLOPE. REUSE EXISTING PENETRATION. PATCH ROOF AS REQUIRED TO MATCH EXISTING, SEE ARCHITECTURAL. EXTEND EXISTING 1-1/2" GAS SUPPLY PIPING AS REQUIRED TO RECONNECT TO ROOF TOP HEAT PUMP [HP -1]. PROVIDE GAS REGULATOR AS REQUIRED SET AT 7" WC. PROVIDE RUBBER SUPPORT WITH GALVANIZED STEEL CHANNEL AND STRUT PIPE CLAMP, SUPPORT MIN. EVERY 10 FT. AND EVERY CHANGE IN DIRECTION. PROVIDE LOCAL SIEMENS CONTROL PANEL IN THE 9-12 BUILDING AND SIEMENS ROOM TEMPERATURE SENSOR TO CONTROL HP -1 AND FUTURE EXPANSION. INTEGRATE CONTROL PANEL WITH THE MAIN SITE WIDE CMOS CONTROL SYSTEM. FSi consulting engineers Seattle, Washington Solutions 8c Service DRAWN I. SIMKIN DATE CHECKED SUBTITLE LEGE\D GE\RAL \OTES 8.5 TON ROOF A/C, MEDIUM CAPACITY GAS HEAT, 460/60/3, ECONOMIZER, DRY BULB 0-100%, POWER EXHAUST, TRANE MODEL YSC102A4. 15 TON ROOF A/C, 203MBH GAS HEAT, 460/60/3, ECONOMIZER, DRY BULB 0-100%, POWER EXHAUST, TRANE MODEL YCD180B4L. 8.5 TON ROOF A/C, MEDIUM CAPACITY GAS HEAT, 460/60/3, ECONOMIZER, DRY BULB 0-100%, POWER EXHAUST, TRANE MODEL YSC102F. 2—TON ROOF TOP HEAT PUMP: TRANE MODEL 4DCY4024C1060A; AIRFLOW: 700 CFM © 0.5" W.C., OA: 55 CFM; POWER: 208-230V/1 PH ACCESSORIES: 15 MBH GAS AUX HEAT, CUSTOM ROOF CURB, DRY BULB ECONOMIZER WITH FAULT DETECTION AND DIAGNOSTICS, PLEATED MERV 8 FILTER, BAROMETRIC RELIEF DAMPER W/HOOD & OUTSIDE AIR TEMPERATURE SENSOR, SIEMENS BACNET COMPATIBLE CONTROL PANEL AND T—STAT. [HP -1] SEQUENCE OF OPERATIONS GENERAL THE HEAT PUMP SHALL MAINTAIN THE SPACE TEMPERATURE SET—POINTS DURING OCCUPIED AND UNOCCUPIED SCHEDULE. OCCUPIED/UNOCCUPIED SET—POINTS SHALL BE 68T/60T AND 75T/80°F FOR HEATING AND COOLING, RESPECTIVELY. ECONOMIZER THE OUTSIDE AIR DRY BULB TEMPERATURE SENSOR SHALL MONITOR THE OUTSIDE AIR CONDITIONS. WHEN OUTSIDE AIR CONDITIONS ARE SUITABLE FOR FREE COOLING AS DETERMINED BY THE ECONOMIZER CONTROLLER, THE ECONOMIZER IS THE FIRST STAGE OF COOLING. THE OUTSIDE AIR DAMPER AND RETURN AIR DAMPERS SHALL MODULATE TO MAINTAIN SPACE SET POINT. OCCUPIED COOLING: THE SUPPLY FAN SHALL RUN CONTINUOUSLY. THE SPACE SET—POINT TEMPERATURE SHALL BE MAINTAINED. THE OUTSIDE AIR DAMPER SHALL OPEN TO MINIMUM POSITION (OA: 55 CFM). UPON A RISE IN TEMPERATURE ABOVE SET POINT, THE 1ST STAGE OF COOLING (ECONOMIZER) IS INITIATED. UPON A CONTINUED RISE IN TEMPERATURE ABOVE THE SET—POINT THE SECOND STAGE OF COOLING (DX) IS INITIATED AND THE OUTSIDE AIR DAMPER RETURNS TO MINIMUM POSITION. HEATING: UPON A DROP IN SPACE TEMPERATURE THE 1ST STAGE HEATING (HEAT PUMP) SHALL BE INITIATED. UPON FURTHER DROP IN SPACE TEMPERATURE THE 2ND STAGE OF HEATING (GAS FIRED) SHALL BE INITIATED. THE 1ST STAGE HEAT PUMP CYCLE SHALL NOT OPERATE BELOW 40 DEGREES F. UNOCCUPIED COOLING: THE SUPPLY FAN SHALL CYCLE TO MAINTAIN SPACE SET—POINT TEMPERATURE. THE OUTSIDE AIR DAMPER SHALL BE CLOSED AND RETURN AIR DAMPER FULLY OPEN. UPON A RISE IN TEMPERATURE THE COOLING SEQUENCE IS INITIATED. HEATING: UPON A DROP IN SPACE TEMPERATURE THE 1ST STAGE HEATING (HEAT PUMP) SHALL BE INITIATED. UPON FURTHER DROP IN SPACE TEMPERATURE THE 2ND (GAS FIRED) STAGE OF HEATING SHALL BE INITIATED. 1ST STAGE H.E.A.T_Ruip CYCI F SHA_L NOT OPERATE BELOW 40 D .LIEFWED FOR Ofi'LI:. C ISSUED FOR CONSTRUCTION JANUARY 04, 2018 ROOF LEVEL PLAN - HVAC Pp OV D FEB 0 7 201 City of Tukwil< BUILDING DIVIS 4 V%% RECEIVED CITY OF TUKWILA JAN 3 0 2018 PERMIT CENTER RFM10 O 4 CURRENT REVISION SYMBOL 34362 DATE 01.04.18 ENGINEER CHECKED APPROVED AWL 01.04.18 01.04.18 S& ED APPROVED TITLE IT SERVICE CENTER BUILDING 9-12 MECHANICAL MASTER COL. A—H/1-3 SHEET RFM10 JOB NO. COMP NO. DWG NO. D.C. 9-12—RFM10 LEGE\D x9 Iatxss #- ON3 3 2'\ 1 1/2" 1 1 /4"\ 1 1/4" 1 1/4"--, If 1 1 �1 0 1/4"--1 „ 0 1 1 /4'! 1 1 /2"-\ 1/2" 1/4" 1 1/4" 1"� 0 1 L 1/4 1 1/2 1 1/2" If 1,, 1 1/2" `'--1 1/4" ,-2» 4" 1" Q „ „ ft If 1 1 /4'\ 1 1 `v1" 1" /2" 1 1/2" 1" „ If 1" 1 1/2" 1" 1" If 2" 1 SYM REVISION TYPICAL FOR ALL DOWN HEADS BY APPROVED DATE TYPICAL FOR ALL UP AND DOWN HEADS SYM w• P . REVISION .4: NAI\ LEVEL PLA\ SCALE: 1/8" = 1'-0" BY APPROVED DATE CONVERSION FROM MYLAR TO CAD CCSI 12.10.00 A A BUILT: 2 HDS IN FREEZER, COL G-2.3 3602 HARR 05/04/09 B IT SERVICE CENTER 34362 FSi AWL 01.04.18 2" PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED „ 11 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE Th 1M260 SEE CIVIL SITE PLANS FOR POC AND CONTINUATION. FSi consulting engineers Seattle, Washington Solutions 8c Service RAWN SUBTITLE D I. SIMKIN DATE CHECKED TO BUILDING SPRINKLER HEADS - FLOW SWITCH ASSEMBLY INTERLOCK TO FIRE ALARM PANEL ALARM VALVE WITH RETARD CHAMBER AND TRIM SYSTEM DRAIN AND TEST CONN FIRE DEPT. SIAMESE CONN 6" —o- ==„;=, 1 WMG a SPRINKLER HEAD, UPRIGHT SPRINKLER HEAD, ABOVE AND BELOW CEILING SPRINKLER HEAD, DRY (HORIZONTAL SIDE WALL) FIRE DEPT. CONNECTION. WALL TYPE, TWO—WAY WATER MOTOR GONG ALARM VALVE FLOW SWITCH SPRINKLER HEAD, PENDANT cE\PaL \orEs SEE KITCHEN DWGS FOR FIRE SPRINKLER CONNECTION TO INTEGRAL KITCHEN HOOD SPRINKLER SYSTEM. 1M111 REFER TO THE ARCHITECTURAL REFLECTED CEILING PLAN FOR BRANCH SPACING IN THE DINING AREA. .EFRE\CE ERAWI\GS CO\ ST�UCTIO\ \OYES MODIFY SPRINKLER HEADS AND PIPING TO ACCOMMODATE MODIFIED CEILING HEIGHT IN THIS AREA. RECONNECT HEADS TO SUPPLY PIPING. WMG C 6" FIDE SPI\ SCALE N.T.S. 4LP HEADE; SCHEvATIC 1M260 0 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 0 7 2018 City of Tukwila BUILDING DIVISION ISSUED FOR CONSTRUCTION JANUARY 04, 2018 MAIN LEVEL PLAN - FIRE SPRINKLERS 4 4 /.4°° 1M260 _ KEY SCALE: NONE PLAN CITY OF TUKWILA JAN 3 0 2018 PERMIT CENTER CURRENT REVISION 34362 SYMBOL 3 DATE 01.04.18 ENCINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER IT SERVICE CENTER BUILDING 9-12 COL. A—H/1-3 D.C. SHEET 1 M260 JOB NO. COMP NO. DWG NO. 9-12-1M260 0,.04.,8 SIGNED MATCHLINE-FOR CONTINUATION SEE SHT. 1M451 0 0 1 1 /2„ / 0 3" UP TO C.O. 1 1/2" 0 1 1/2 It 3 2" UP TO C.O. 1 1/2" 1 1/2 1 1M450 1M452 AP 2. 2610, 0 1 1/2" 100•—,2» 2" o-' 2" UP TO C.O. 2' „ SAN GREASE INTERCEPTOR 4" —1-- sAN 1 1 /2" 1/2" TRAP PRIMER TYP. PARTIAL FL0N PLA\ SCALE: 1/4" = 1'-0" 2" C.O. 0 SEE CIVIL DRAWINGS FOR CONTINUATION OF INCOMING SERVICE AT POINT OF CONNECTION 1/2" TRAP PRIMER TYP 2" "7›c--01, 3"" 4" o'• 1 1/2 „ ` \ 3" COLD WATER SEE CIVIL DRAWINGS FOR CONTINUATION OF INCOMING SERVICE AT POINT OF CONNECTION PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED 6" FIRE SPRINKLER MAIN FSi consulting engineers Seattle, Washington Solutions & Service AP7 2212Q1' A PLUN3I\G LEGE\D __HI CO FCO I wco D T N HB CO\ST CLEAN OUT, EXPOSED CLEAN OUT, FLOOR CLEAN OUT, WALL COLD WATER, DOMESTIC HOT WATER, DOMESTIC HOT WATER, CIRCULATING DOMESTIC NATURAL GAS INDIRECT DRAIN SANITARY WASTE VENT ELBOW UP, DN., SIDE TEE UP, DN., SIDE CAP, SCREWED OR SOLDER CONCENTRIC REDUCER UNION BALL VALVE GATE VALVE GLOBE VALVE, N.C. GAS PLUG VALVE BALANCING VALVE CHECK VALVE NON —FREEZE HOSE BIB PRESSURE REDUCING VALVE TEMPERATURE AND PRESSURE RELIEF VALVE SOLENOID VALVE FLEXIBLE CONNECTOR PRESSURE GAGE STEM, THERMOMETER PIPE MOUNTED CIRCULATION PUMP STRAINER WITH BLOW —OFF GLOBE VALVE l CT10\ \OTES ISSUED FOR CONSTRUCTION JANUARY 04, 2018 CONNECT THE RELOCATED EXISTING MOP SINK, TO THE EXISTING 2"W P—TRAP IN FLOOR. REVIEWED FOR CODE COMPLIANCE APPROVED FEB 07 2018 City of Tukwila BUILDING DIVISIO RECEIVE CITY OF TUKWILA JAN 3 0 2018 PERMIT CENTER 4 Q SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE CONVERSION FROM MYLAR TO CAD CCS1 12.10.00 A IT SERVICE CENTER 34362 FSi AWL 01.04.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN I. SIMKIN DATE CHECKED SUBTITLE FOUNDATION PARTIAL PLAN - PIPING CURRENT REVISION 34362 SYMBOL A DATE 01.04.18 ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER IT SERVICE CENTER BUILDING 9-12 COL. E—H/2-3 D.C. SHEET 1 M450 JOB NO. COMP NO. DWG NO. 9-12-1M450 01.04.18 SD XED LEGE 1/2 0 1 1/2" *FSP32 U V U Lcw C108 cw cw — cw 1/2" cyf cw 1 2 3/4" 2" — 3/4" 2 1/2" 3/4' 2 1/2 3/4' G--t—G -0-- 3/4z vJFS I�P -Q--It 0 „ 0 /-- 1 1/2" A v 3„ FSP17* FS car cw cw 713 *FSP26 ---"1" *FSP19 1 *FSP21 1" *FSP14 1/2" *FSP11 1/2" *FSP11 �- FLOOR TROU 3/4" *FSP2 1 *FSP11 1/2" *FSP11 1/2" *FSP11 �� 3/4" *FSP222 hT1/2»v v *FSI 1 /2 *FSP9 1 1/4" *FSP9 1/2" *FSP29' 1/2" *FSP2 �1/2" * SP1 / 1 1/2" 2" 1/2" *FSP42 1SP16*, 15 c---] HWC HWC HW v I — E� 2" / FCO 0 21 2"3 FS = v HW 0 cw U 0 1 ' /2" FSP5* 3/4" U 1 /2" FS 4" 3/4 3/4' *FSP 1 1/2" 1/2 FSP38* 3/4' 1M452 1 1/2" 2" 3/4" FSP8* 3" VTR > *FSP1 3/4"' 1M455 1 /2" FSP6* 1/2" FSP35* 1 1/2" FSP34* 0 (1� 1M452 1M454 *FSF44 � 3" *FSP2 3/4" *FSP1 SYM REVISION 1/2" *FSP25 1/2" *FSP31 1/2" *FSP43 BY 1 1/2" APPROVED 1/2 " DATE SYM 1 1 /2" REVISION PARTIAL FL0CH PLA\ SCALE: 1/4" = 1'-0" BY APPROVED DATE CONVERSION FROM MYLAR TO CAD CCSI A INSTALL SEISMIC GAS SHUTOFF VALVE 56755500 HARR 12.10.00 04/17/07 8 IT SERVICE CENTER 34362 FSi AWL 01.04.18 MIXING VALVE 44% 1M45. 1M455 Ar 2.1j 4_ WC —1 0 NFHB FFD 4" 3/4" 2" 3" WHIW2 PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED C50 Al-39 1M452 1M455 ACCEPTABILITY THIS DESIGN AND/OR SPECIRCATION IS APPROVED APPROVED BY DEPT. DATE 1M452 1M454 c39 FSi consulting engineers Seattle, Washington Solutions 8c Service DRAWN I. SIMKIN DATE CHECKED SUBTITLE 1,0 2.1 2. co FCO Cw HW - HWC G ID ID — SAN v v wco cw HW HWC G CLEAN OUT, EXPOSED CLEAN OUT, FLOOR CLEAN OUT, WALL COLD WATER, DOMESTIC HOT WATER, DOMESTIC HOT WATER, CIRCULATING DOMESTIC NATURAL GAS INDIRECT DRAIN SAN SANITARY WASTE —S T —+-01 f HB GE\ VENT ELBOW UP, DN., SIDE TEE UP, DN., SIDE CAP, SCREWED OR SOLDER CONCENTRIC REDUCER UNION BALL VALVE GATE VALVE GLOBE VALVE, N.C. GAS PLUG VALVE BALANCING VALVE CHECK VALVE NON —FREEZE HOSE BIB PRESSURE REDUCING VALVE TEMPERATURE AND PRESSURE RELIEF VALVE SOLENOID VALVE FLEXIBLE CONNECTOR PRESSURE GAGE STEM, THERMOMETER PIPE MOUNTED CIRCULATION PUMP STRAINER WITH BLOW —OFF GLOBE VALVE EAL \OTES REFER TO THE FOOD SERVICE EQUIPMENT LAYOUT PLANS AND SCHEDULES FOR EXACT PLUMBING ROUGH —IN LOCATIONS AND EQUIPMENT CONNECTION SIZES AND ALSO INDIRECT WASTE PIPING REQUIREMENTS, REFER TO THE FOOD SERVICE SCHEDULES FOR EQUIPMENT DESIGNATIONS. *FIXTURE FURNISHED & INSTALLED BY G.C. PIPING ROUGH —IN & CONN. BY M.C. GAS PRESSURE REDUCING STATION MFG: FISHER PRESSURE IN, RESSURE OUT, 10" W.C. FLOW RATE, 5300 CFH PROVIDE RELIEF VALVE AND EXTEND RELIEF VENT UP THRU ROOF. CO\S-RUCTIO\ \OYES ENFAggl-FIW R LOCATED EXISTING MOP SINK TO fg) 1-HW IN THE WALL. VE FEB 07 2018 City of Tukwila BUILDING DIVISION ISSUED FOR CONSTRUCTION JANUARY 04, 2018 FIRST FLOOR PARTIAL PIPING PLAN RECEIVED CITY OF TUKVViL; JAN 3 0 2018 PERMIT CENTER CURRENT REVISION 34362 SYMBOL 3 DATE 01.04.18 ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER IT SERVICE CENTER BUILDING 9-12 COL. E—H/2-3 D.C. SHEET 1M452 JOB NO. COMP NO. DWG NO. 01.04.18 SIGIND 9-12-1M452 FIRE DEPARTMENT CONNECTION S ICTI O SCALE: 1 /4"=1'-0" \-RETURN GRILLE 8"0 14"010"0 SUPPLY GRILLE D 1M501 1M10 SEE TYPICAL AHU VIBRATION ISOLATION CURB DETAIL ON THIS DWG. SEE SPEC. SECTION 15240 S ECTI O SCALE: 1 /4"=1 '-0" COORDINATE THE EXACT LOCATIONS FOR DUCT —SMOKE DETECTORS (BY E.C.) SO AS TO BE FULLY ACCESSIBLE PROVIDE NECESSARY ACCESS PANEL TYPICAL FOR ALL OF THE ROOFTOP AIR HANDLING UNITS. c 1M501I 1M10 ROOF TOP UNIT CURB ACOUSTICAL BARRIER - SEISMIC SPRING VIBRATION ISOLATION CURB. (SPEC 15240) FLEX DUCT CONN AROUND DUCT. TYP. 2"x2"x1/8" ANGLE IRON AROUND DUCT TT r-1 rfl 18 GAGE DUCT TYP. 2"/3LB INSULATION TYP. HAT CHANNEL SUPPORT. TYP. PERFORATED METAL LINER. TYP. SOUND ATTENUATOR (SEE SPEC. 15880) L LL L= ± L. LL L. L. DETAIL -GOOF U\ITSTYPICAL 1 SCALE: N.T.S. PROFESSIONAL STAMP & SIGNATURE APPLIES TO WORK WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED 1 M501LM 10 FSi consulting engineers Seattle, Washington Solutions 8c Service APR 2121 CO\S-RUCTIO\ \CTES FLEX. DUCT CONN. TYP. LEVELING CURB BY G.C. ROOF ISSUED FOR CONSTRUCTION JANUARY 04, 2018 PROVIDE 1/2' THICK RUBBER GASKET BETWEEN ROOF CURB AND UNIT. PROVIDE FLEX DUCT CONNECTION AT THE SUPPLY AND RETURN DUCT CONNECTIONS TO THE UNIT. APR 2.,.2 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 07 2018 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWIL A JAN 30 2018 PERMIT CENTER SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE CONVERSION FROM MYLAR TO CAD CCSI 12.10.00 A IT SERVICE CENTER 34362 FSi AWL 01.04.18 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN I. SIMKIN DATE CHECKED ENGINEER CHECKED SUBTITLE BUILDING SECTION DETAILS CURRENT REVISION 34362 SYMBOL A DATE 01.04.18 APPROVED APPROVED TITLE MECHANICAL MASTER IT SERVICE CENTER BUILDING 9-12 COL. 1-3 D.C. SHEET 1M501 JOB NO. COMP NO. DWG NO. 9-12-1M501 01.04.18 SAGA60